DENSEI-LAMBDA HWS50/ME SPECIFICATIONS A226-01-01/ME HWS50 HWS50 HWS50 HWS50 -12/ME -15/ME -24/ME -48/ME 12 15 24 48 1 V 4.3 3.5 2.2 1.1 2 A 51.6 52.5 52.8 52.8 3 W 81 81 82 83 4 % 83 83 84 85 % 5 85 - 265VAC (47 - 63Hz) or 120 - 370VDC 6 A 0.7/0.35 7 14A at 100VAC, 28A at 200VAC, Ta=25C, Cold Start 8 Designed to meet IEC61000-3-2 9 Designed to meet IEC61000-3-3 0.99/0.95 10 4.0 - 6.0 9.6 - 14.4 12.0 - 18.0 19.2 - 28.8 38.4 - 52.8 11 V 120 150 150 150 200 12 mV 160 180 180 180 240 mV 20 48 60 96 192 13 mV 40 96 120 192 384 14 mV 15 Less than 0.02% / C 10.5 < 4.51 < 3.67 < 2.31 < 1.15 < 16 A 6.25 - 7.25 15.0 - 17.4 18.8 - 21.8 30.0 - 34.8 55.2 - 64.8 17 V 18 20ms 19 Less than 0.5mA. 0.2mA(Typ) at 100VAC / 0.4mA(Typ) at 230VAC 20 21 22 Possible 23 -10 to +70C (-10 to +50C:100%,+60C:60%,+70C:20%) 24 30 to 90%RH (No dewdrop) 25 -30 to +85C 26 10 to 95%RH (No dewdrop) 27 Convection cooling 28 Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA) Output - FG : 500VAC (100mA) for 1min 29 Isolation Resistance More than 100M at 25C and 70%RH Output - FG : 500VDC 30 Vibration At no operating, 10 - 55Hz (Sweep for 1min) 19.6m/s2 Constant, X,Y,Z 1hour each. 31 Shock (In package) Less than 196.1m/s2 32 Safety (*12) Approved by UL60601-1, EN60601-1, CSA-C22.2 No.601.1-M90 33 Line DIP Designed to meet SEMI-F47 (200VAC Line only) 34 Conducted Emission Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B 35 Radiated Emission Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B 36 Immunity Designed to meet IEC61000-4-2(Level 3), -3(Level 3), -4(Level 3), -5(Level 3,4), -6(Level 3), -8(Level 4), -11 37 Weight(Typ.) 280g 38 Size (W x H x D) mm 26.5 x 82 x 120 ( Refer to Outline Drawing ) *Read instruction manual carefully, before using the power supply unit. =NOTES= *1. At 100/200VAC, Ta=25C and maximum output power. *2. For cases where conformance to various safety specs (UL, EN, CSA) are required, to be described as 100 - 230VAC(50/60Hz). *3. Not applicable for the in-rush current to Noise Filter for less than 0.2ms. *4. Measure with JEITA RC-9131A probe, Bandwidth of scope :100MHz. *5. 85 - 265VAC , constant load. *6. No load-Full load, constant input voltage. *7. Constant current limit and Hiccup with automatic recovery. Not operate at over load or dead short condition for more than 30seconds. *8. OVP circuit will shutdown output, manual reset (Re power on). *9. At 100/200VAC , nominal output voltage and maximum output current. *10. Measured by the each measuring method of UL,EN and CSA(at 60Hz). When using it as a patient care equipment, all outer surfaces of the equipment shall be constructed of nonconductive material. See clause 19.5DV.2 of UL60601-1. *11. Ratings - Derating at standard mounting. - Load (%) is percent of maximum output power or maximum output current, whichever is greater. - As for other mountings, refer to derating curve (A226-01-02_). *12. As for UL60601-1, EN60601-1 and CSA-C22.2 No.601.1-M90, basic insulation. MODEL ITEMS Nominal Output Voltage Maximum Output Current Maximum Output Power Efficiency (Typ) (*1) 100VAC 200VAC Input Voltage Range (*2) Input Current (100/200VAC)(Typ) (*1) Inrush Current(Typ) (*3) PFHC Voltage Fluctuations / Flicker Emissions Power Factor (100/200VAC)(Typ) (*1) Output Voltage Range Maximum Ripple & Noise 0