User's Guide Hall IC BD7411G-EVK-001 Manual BD7411G-EVK-001 is an evaluation board for BD7411G, which is a ROHM Hall IC. This User's Guide is about how to use BD7411G-EVK-001 together with SensorShield*1. *1 SensorShield is sold as Shield-EVK-001. Preparation Arduino Uno 1pc Personal Computer installed Arduino IDE 1pc Requirement : Arduino 1.6.7 or higher Please use Arduino IDE which can be downloaded from the link below: http://www.arduino.cc/ USB cable for connecting Arduino and PC 1pc SensorShield 1pc BD7411G-EVK-001 1pc Magnet 1pc Figure 2. Connection between BD7411G-EVK-001 and the SensorShield Setting 1. Connect the Arduino and the SensorShield (Figure 1) 4. Connect the Arduino to the PC using a USB cable 5. Download BD7411G.zip from the link below: http://www.rohm.com/web/global/sensor-shield-support SensorShield USB connecter 6. Launch Arduino IDE 7. Select [Sketch]->[Include Library]->[Add.ZIP library...], install BD7411G.zip 8. Select [File]->[Examples]->[BD7411G]->[example]-> [BD7411G] Figure 1. Connection between the Arduino and the SensorShield 2. Connect BD7411G-EVK-001 to the socket of GPIO area on the SensorShield (Figure 2) 3. Set Voltage of the SensorShield to 5.0V (Figure 2) (c) 2018 ROHM Co., Ltd. 1/2 No. 60UG061E Rev.001 Apr.2018 BD7411G-EVK-001 Manual User's Guide Measurement 1. 7. Check log of Serial Monitor (Figure 6) "BD7411G Magnet field Detect!" is displayed when the Select [Tools] and check the contents enclosed in the red magnet is placed near the sensor board. frame. (Figure 3) Board should be "Arduino/Genuino Uno" and Port should be COMxx (Arduino/Genuino Uno). COM port number is different in each environment. Figure 6. Serial Monitor Figure 3. COM Port setting 2. Remove BD7411G-EVK-001 from the SensorShield 3. Write the program by pressing right arrow button for Board Information upload (Figure 4) 4. Wait for the message "Done uploading" (Figure 4) Figure 7. Picture of the board Figure 4. Uploading 5. Connect BD7411G-EVK-001 to the SensorShield 6. Select [Tools]->[Serial Monitor] (Figure 5) Table 1. Parts information Figure 5. Tools Setting (c) 2018 ROHM Co., Ltd. 2/2 No. 60UG061E Rev.001 Apr.2018 Notice Notes 1) The information contained herein is subject to change without notice. 2) Before you use our Products, please contact our sales representative and verify the latest specifications : 3) Although ROHM is continuously working to improve product reliability and quality, semiconductors can break down and malfunction due to various factors. Therefore, in order to prevent personal injury or fire arising from failure, please take safety measures such as complying with the derating characteristics, implementing redundant and fire prevention designs, and utilizing backups and fail-safe procedures. ROHM shall have no responsibility for any damages arising out of the use of our Poducts beyond the rating specified by ROHM. 4) Examples of application circuits, circuit constants and any other information contained herein are provided only to illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. 5) The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM or any other parties. ROHM shall have no responsibility whatsoever for any dispute arising out of the use of such technical information. 6) The Products specified in this document are not designed to be radiation tolerant. 7) For use of our Products in applications requiring a high degree of reliability (as exemplified below), please contact and consult with a ROHM representative : transportation equipment (i.e. cars, ships, trains), primary communication equipment, traffic lights, fire/crime prevention, safety equipment, medical systems, servers, solar cells, and power transmission systems. 8) Do not use our Products in applications requiring extremely high reliability, such as aerospace equipment, nuclear power control systems, and submarine repeaters. 9) ROHM shall have no responsibility for any damages or injury arising from non-compliance with the recommended usage conditions and specifications contained herein. 10) ROHM has used reasonable care to ensurH the accuracy of the information contained in this document. However, ROHM does not warrants that such information is error-free, and ROHM shall have no responsibility for any damages arising from any inaccuracy or misprint of such information. 11) Please use the Products in accordance with any applicable environmental laws and regulations, such as the RoHS Directive. For more details, including RoHS compatibility, please contact a ROHM sales office. ROHM shall have no responsibility for any damages or losses resulting non-compliance with any applicable laws or regulations. 12) When providing our Products and technologies contained in this document to other countries, you must abide by the procedures and provisions stipulated in all applicable export laws and regulations, including without limitation the US Export Administration Regulations and the Foreign Exchange and Foreign Trade Act. 13) This document, in part or in whole, may not be reprinted or reproduced without prior consent of ROHM. Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us. ROHM Customer Support System http://www.rohm.com/contact/ ZZZURKPFRP 652+0&R/WG$OOULJKWVUHVHUYHG 5%