60 V, 22 A, 16.5 mΩ Low RDS(ON)
N ch Trench Power MOSFET
GKI06259
GKI06259-DS Rev.1.6 SANKEN ELECTRIC CO.,LTD. 1
Mar. 11, 2015
Features
V(BR)DSS --------------------------------- 60 V (ID = 100 µA)
ID ---------------------------------------------------------- 22 A
RDS(ON) -------- 21.7 mΩ max. (VGS = 10 V, ID = 12.5 A)
Qg ------- 6.6 nC (VGS = 4.5 V, VDS = 30 V, ID = 15.8 A)
Low Total Gate Charge
High Speed Switching
Low On-Resistance
Capable of 4.5 V Gate Drive
100 % UIL Tested
RoHS Compliant
Applications
DC-DC converters
Synchronous Rectification
Power Supplies
Package
DFN 5 × 6
Not to scale
Equivalent circuit
Absolute Maximum Ratings
Unless otherwise specified, TA = 25 °C
Parameter
Symbol
Test conditions
Rating
Unit
Drain to Source Voltage
VDS
60
V
Gate to Source Voltage
VGS
± 20
V
Continuous Drain Current
ID
TC = 25 °C,
with infinite heatsink
22
A
TA = 25 °C,
mounted on PCB*
6
A
Pulsed Drain Current
IDM
PW 100µs
Duty cycle 1 %
43
A
Continuous Source Current
(Body Diode)
IS
26
A
Pulsed Source Current
(Body Diode)
ISM
PW 100µs
Duty cycle 1 %
43
A
Single Pulse Avalanche Energy
EAS
VDD = 30 V, L = 1 mH,
IAS = 4.2 A, unclamped,
RG = 4.7 Ω,
Refer to Figure 1
18
mJ
Avalanche Current
IAS
10
A
Power Dissipation
PD
TC = 25 °C,
with infinite heatsink
40
W
TA = 25 °C,
mounted on PCB*
3.1
W
Operating Junction Temperature
TJ
150
°C
Storage Temperature Range
TSTG
55 to 150
°C
* 1 inch square 2 oz copper pad on 1.5 × 1.5 inch PCB.
D(5)(6)(7)(8)
S(1)(2)(3)
G(4)
http://www.sanken-ele.co.jp
S S S G
D D D D
G S S S
D D D D
1pin
8pin
GKI06259
GKI06259-DS Rev.1.6 SANKEN ELECTRIC CO.,LTD. 2
Mar. 11, 2015
Thermal Characteristics
Unless otherwise specified, TA = 25 °C
Parameter
Symbol
Test Conditions
Min.
Typ.
Max.
Unit
Thermal Resistance
(Junction to Case)
RθJC
3.1
°C/W
Thermal Resistance
(Junction to Ambient)
RθJA
Mounted on PCB*
40.3
°C/W
* 1 inch square 2 oz copper pad on 1.5 × 1.5 inch PCB.
Electrical Characteristics
Unless otherwise specified, TA = 25 °C
Parameter
Symbol
Test Conditions
Min.
Typ.
Max.
Unit
Drain to Source Breakdown
Voltage
V(BR)DSS
ID = 100 μA, VGS = 0 V
60
V
Drain to Source Leakage Current
IDSS
VDS = 60 V, VGS = 0 V
100
µA
Gate to Source Leakage Current
IGSS
VGS = ± 20 V
± 100
nA
Gate Threshold Voltage
VGS(th)
VDS = VGS, ID = 250 µA
1.0
2.0
2.5
V
Static Drain to Source
On-Resistance
RDS(ON)
ID = 12.5 A, VGS = 10 V
16.5
21.7
ID = 6.3 A, VGS = 4.5 V
20.4
26.8
Gate Resistance
RG
f = 1 MHz
3.0
Ω
Input Capacitance
Ciss
VDS = 25 V
VGS = 0 V
f = 1 MHz
1050
pF
Output Capacitance
Coss
125
Reverse Transfer Capacitance
Crss
53
Total Gate Charge (VGS = 10 V)
Qg1
VDS = 30 V
ID = 15.8 A
14.7
nC
Total Gate Charge (VGS = 4.5 V)
Qg2
6.6
Gate to Source Charge
Qgs
2.2
Gate to Drain Charge
Qgd
2.1
Turn-On Delay Time
td(on)
VDD = 30 V
ID = 15.8 A
VGS = 10 V, RG = 4.7 Ω
Refer to Figure 2
1.9
ns
Rise Time
tr
2.3
Turn-Off Delay Time
td(off)
10.9
Fall Time
tf
5.0
Source to Drain Diode Forward
Voltage
VSD
IS = 12.5 A, VGS = 0 V
0.9
1.5
V
Source to Drain Diode Reverse
Recovery Time
trr
IF = 15.8 A
di/dt = 100 A/µs
Refer to Figure 3
28.7
ns
Source to Drain Diode Reverse
Recovery Charge
Qrr
32.3
nC
GKI06259
GKI06259-DS Rev.1.6 SANKEN ELECTRIC CO.,LTD. 3
Mar. 11, 2015
Test Circuits and Waveforms
VDD
ID
VDS
RG
VGS
0 V
L
IAS
ID
V(BR)DSS
VDD
VDS
(a) Test Circuit (b) Waveform
Figure 1 Unclamped Inductive Switching
VDS
VDD
RG
RL
VGS
0 V
P.W. = 10 μs
Duty cycle 1 %
td(on) tr
ton
td(off) tf
toff
90%
10%
90%
10%
VGS
VDS
(a) Test Circuit (b) Waveform
Figure 2 Switching Time
VGS
0 V
IF
RG
L
D.U.T.
VDD
0 V
IF
trr
di/dt IRM × 90 %
IRM
(a) Test Circuit (b) Waveform
Figure 3 Diode Reverse Recovery Time
DD(BR)DSS
(BR)DSS
2
ASAS VV
V
IL
2
1
E
GKI06259
GKI06259-DS Rev.1.6 SANKEN ELECTRIC CO.,LTD. 4
Mar. 11, 2015
0
5
10
15
20
25
30
35
40
45
010 20 30 40 50
RDS(ON) (mΩ)
ID (A)
RDS(ON)-ID characteristics (typical)
VGS=10V
Tc = 125
75
25
0
10
20
30
40
50
60
70
010 20 30 40 50
RDS(ON) (mΩ)
ID (A)
RDS(ON)-ID characteristics (typical)
VGS=4.5V
Tc = 125
75
25
0
10
20
30
40
50
0 1 2 3 4 5
ID (A)
VGS (V)
ID-VGS characteristics (typical)
VDS=5V
Tc =125
75
25
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0 5 10 15
VDS (V)
VGS (V)
VDS-VGS characteristics (typical)
ID=6.3A
ID=7.9A
ID=12.5A
Tc=25
0
10
20
30
40
50
0 0.5 1 1.5
IDR (A)
VSD (V)
IDR-VSD characteristics (typical)
Tc=25
VGS=10V
VGS=4.5V
3V
0V
0
10
20
30
40
50
0 0.5 1 1.5
IDR (A)
VSD (V)
IDR-VSD characteristics (typical)
VDS=0V
Tc =125
75
25
10
100
1000
10000
010 20 30 40 50
Capacitance (pF)
VDS (V)
Capacitance-VDS characteristics (typical)
Ciss
Coss
Crss
Ta=25
VGS=0V
f=1MHz
0
5
10
15
0 5 10 15
VGS (V)
Qg (nC)
VGS - Qg characteristics (typical)
Tc=25
VDS=30V
ID=15.8A
0
1
2
3
25 50 75 100 125 150
Vth (V)
Tc ()
Vth-Tc characteristics (typical)
ID=250uA
VGS=VDS
0
5
10
15
20
25
30
35
40
25 50 75 100 125 150
RDSON(mΩ)
Tc ()
RDS(ON)-Tc characteristics (typical)
ID=12.5A
VGS=10V
0
5
10
15
20
25
30
35
40
45
25 50 75 100 125 150
RDSON(mΩ)
Tc ()
RDS(ON)-Tc characteristics (typical)
ID=6.3A
VGS=4.5V
62
64
66
68
70
72
74
76
25 50 75 100 125 150
BVDSS (V)
Tc ()
BVDSS-Tc characteristics (typical)
ID=1mA
VGS=0V
GKI06259
GKI06259-DS Rev.1.6 SANKEN ELECTRIC CO.,LTD. 5
Mar. 11, 2015
0
10
20
30
40
50
050 100 150
PD (W)
Ta ()
PD-Ta Derating
0.1
1
10
100
0.1 1 10 100
ID (A)
VDS (V)
SAFE OPERATING AREA
PT=100μs
ID(pulse) MAX
PT=1ms
1 shot
Tc=25
1.E-02
1.E-01
1.E+00
1.E+01
1.E-04 1.E-03 1.E-02 1.E-01 1.E+00 1.E+01 1.E+02
Rth j-c (/W)
P.T. (sec)
TRANSIENT THERMAL RESISTANCE - PULSE WIDTH
Tc = 25
1shot
VDS < 10V
GKI06259
GKI06259-DS Rev.1.6 SANKEN ELECTRIC CO.,LTD. 6
Mar. 11, 2015
Package Outline
DFN 5 × 6
NOTES:
1) Dimension is in millimeters
2) Pb-free. Device composition compliant with the RoHS directive
Marking Diagram
Part Number
YMDDXXXB
GKI×××××
SK
Lot Number
Y is the Last digit of the year (0 to 9)
M is the Month (1 to 9, O, N or D)
DD is the Date (two digit of 01 to 31)
XXX is the suffix No.
B expresses Pb free pins
Symbol Min. Max.
A 1.03 1.17
b 0.34 0.48
C 0.824 0.970
D 4.80 5.40
D1 4.11 4.31
D2 4.80 5.00
E 5.95 6.15
E1 5.65 5.85
E2 1.60 --
e
L 0.05 0.25
L1 0.38 0.50
L2 0.38 0.50
H 3.30 3.50
I -- 0.18
1.27
GKI06259
GKI06259-DS Rev.1.6 SANKEN ELECTRIC CO.,LTD. 7
Mar. 11, 2015
OPERATING PRECAUTIONS
In the case that you use Sanken products or design your products by using Sanken products, the reliability largely
depends on the degree of derating to be made to the rated values. Derating may be interpreted as a case that an operation
range is set by derating the load from each rated value or surge voltage or noise is considered for derating in order to
assure or improve the reliability. In general, derating factors include electric stresses such as electric voltage, electric
current, electric power etc., environmental stresses such as ambient temperature, humidity etc. and thermal stress caused
due to self-heating of semiconductor products. For these stresses, instantaneous values, maximum values and minimum
values must be taken into consideration. In addition, it should be noted that since power devices or IC’s including power
devices have large self-heating value, the degree of derating of junction temperature affects the reliability significantly.
Because reliability can be affected adversely by improper storage environments and handling methods, please
observe the following cautions.
Cautions for Storage
Ensure that storage conditions comply with the standard temperature (5 to 35°C) and the standard relative humidity
(around 40 to 75%); avoid storage locations that experience extreme changes in temperature or humidity.
Avoid locations where dust or harmful gases are present and avoid direct sunlight.
Reinspect for rust on leads and solderability of the products that have been stored for a long time.
Cautions for Testing and Handling
When tests are carried out during inspection testing and other standard test periods, protect the products from power
surges from the testing device, shorts between the product pins, and wrong connections. Ensure all test parameters are
within the ratings specified by Sanken for the products.
Remarks About Using Thermal Silicone Grease
When thermal silicone grease is used, it shall be applied evenly and thinly. If more silicone grease than required is
applied, it may produce excess stress.
The thermal silicone grease that has been stored for a long period of time may cause cracks of the greases, and it
cause low radiation performance. In addition, the old grease may cause cracks in the resin mold when screwing the
products to a heatsink.
Fully consider preventing foreign materials from entering into the thermal silicone grease. When foreign material
is immixed, radiation performance may be degraded or an insulation failure may occur due to a damaged insulating
plate.
The thermal silicone greases that are recommended for the resin molded semiconductor should be used.
Our recommended thermal silicone grease is the following, and equivalent of these.
Type
Suppliers
G746
Shin-Etsu Chemical Co., Ltd.
YG6260
Momentive Performance Materials Japan LLC
SC102
Dow Corning Toray Co., Ltd.
Soldering
When soldering the products, please be sure to minimize the working time, within the following limits:
Reflow Preheat ; 180 °C / 90 ± 30 s
Solder heating ; 250 °C / 10 ± 1s (260 °C peak, 2 times)
Soldering iron ; 380 ± 10 °C / 3.5 ± 0.5s (1 time)
Electrostatic Discharge
When handling the products, the operator must be grounded. Grounded wrist straps worn should have at least 1MΩ
of resistance from the operator to ground to prevent shock hazard, and it should be placed near the operator.
Workbenches where the products are handled should be grounded and be provided with conductive table and floor
mats.
When using measuring equipment such as a curve tracer, the equipment should be grounded.
When soldering the products, the head of soldering irons or the solder bath must be grounded in order to prevent
leak voltages generated by them from being applied to the products.
The products should always be stored and transported in Sanken shipping containers or conductive containers, or
be wrapped in aluminum foil.
GKI06259
GKI06259-DS Rev.1.6 SANKEN ELECTRIC CO.,LTD. 8
Mar. 11, 2015
IMPORTANT NOTES
The contents in this document are subject to changes, for improvement and other purposes, without notice. Make
sure that this is the latest revision of the document before use.
Application examples, operation examples and recommended examples described in this document are quoted for
the sole purpose of reference for the use of the products herein and Sanken can assume no responsibility for any
infringement of industrial property rights, intellectual property rights, life, body, property or any other rights of
Sanken or any third party which may result from its use.
Unless otherwise agreed in writing by Sanken, Sanken makes no warranties of any kind, whether express or
implied, as to the products, including product merchantability, and fitness for a particular purpose and special
environment, and the information, including its accuracy, usefulness, and reliability, included in this document.
Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure and
defect of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at
their own risk, preventative measures including safety design of the equipment or systems against any possible
injury, death, fires or damages to the society due to device failure or malfunction.
Sanken products listed in this document are designed and intended for the use as components in general purpose
electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring
equipment, etc.).
When considering the use of Sanken products in the applications where higher reliability is required (transportation
equipment and its control systems, traffic signal control systems or equipment, fire/crime alarm systems, various
safety devices, etc.), and whenever long life expectancy is required even in general purpose electronic equipment
or apparatus, please contact your nearest Sanken sales representative to discuss, prior to the use of the products
herein.
The use of Sanken products without the written consent of Sanken in the applications where extremely high
reliability is required (aerospace equipment, nuclear power control systems, life support systems, etc.) is strictly
prohibited.
When using the products specified herein by either (i) combining other products or materials therewith or (ii)
physically, chemically or otherwise processing or treating the products, please duly consider all possible risks that
may result from all such uses in advance and proceed therewith at your own responsibility.
Anti radioactive ray design is not considered for the products listed herein.
Sanken assumes no responsibility for any troubles, such as dropping products caused during transportation out of
Sanken’s distribution network.
The contents in this document must not be transcribed or copied without Sanken’s written consent.