Stand Alone Inclinometer
Rev. 27 Aug 2004 VTI Technologies reserves the right to modify this specification without prior to notice.
Preliminary
SCA114T and SCA124T Series
FEATURES
• ±30° or ±90° for inclination measurement
• 4…20mA current loop output
• 10…36V supply voltage
• High repeatability/stability 0,03°
• >20 000g shock resistant sensing element
• IP67 housing
• Standard M12 sensor connectror
• Reverse polarity protected
BENEFITS
• Excellent long term stability
• Outstanding shock durability
• Harsh environment robustness
APPLICATIONS
• Platform tilt measurement
• Equipment and instrument condition monitoring
• Inclination based position measurement
• Rotational orientation measurement (dual axis)
ELECTRICAL CHARACTERISTICS
Parameter Condition Min. Typ Max. Units
Supply voltage Non stabilized 10 36 V
Output Current output 4 20 mA
Output (1 Voltage output 1 5 V
Output (2 Voltage output 0 10 V
PERFORMANCE CHARACTERISTICS
Parameter Condition SCA114T-D02FA SCA114T-D04FA SCA124T-D02FA SCA124T-D04FA Units
Measuring range (FS) ± 30 ± 90 ±30 ±90 °
Measuring direction (see “Directions”) X X X-Y X-Y
Repeatability (3 @ 0° position <0.03 <0.03 <0.03 <0.03 °
Resolution / Noise DC ... 10 Hz 0.003 0.003 0.003 0.003 °
Offset (4,5 0° position 12 12 12 12 mA
Offset accuracy (5 Deviation @ 0° 0.08 0.25 0.08 0.25 °
Sensitivity (3 ±8 ±8±8±8 mA/FS
Cross-axis sensitivity (6 4 4 4 4 %
Frequency response LP (-3 dB point) (7 1 1 1 1 Hz
Operating temperature -40 ... +85 -40 ... +85 -40 ... +85 -40 ... +85 °C
Long term stability 500 h @ 23°C 0.03 0.03 0.03 0.03 °
Housing Closed connector IP67 IP67 IP67 IP67
For customised product please contact VTI Technologies
Note 1. Output current measured over 250Ω load resistor.
Note 2. Output current measured over 500Ω load resistor.
Note 3. Output function trigonometrical (sine curve) ; ϕ = arcsin(Iout)
Note 4. Offset specified as Output @ 0°.
Note 5. Mounting accuracy depending. Position should be calibrated. See measuring positions.
Note 6. The cross-axis sensitivity determines how much acceleration or inclination, perpendicular
to the measuring axis, couples to the output. The total cross-axis sensitivity is
the geometric sum of the sensitivities of the two axises which are perpendicular to
the measuring axis.
Note 7. The output has true DC (0Hz) response.
Current Output