Advanced Power
Electronics Corp. APE1117A
ELECTRICAL SPECIFICATIONS(Cont.)
Parameter MIN TYP MAX UNITS
APE1117AX-ADJ VIN=3.3V,10mA≦IOUT≦1A, TJ=25°C - 0.4 1 %
APE1117AX-15 VIN=3V, 10mA≦IOUT≦1A, TJ=25°C
(Note 1,2) -1215mV
APE1117AX-18 VIN=3.3V, 0mA≦IOUT≦1A, TJ=25°
C (Note 1,2) -1518mV
APE1117AX-25 VIN=4V, 10mA≦IOUT≦1A, TJ=25°C
(Note 1,2) -2025mV
APE1117AX-33 VIN=5V,10mA≦IOUT≦1A, TJ=25°C
(Note 1,2) -2633mV
APE1117AX-50 VIN=6.5V,10mA≦IOUT≦1A, TJ=25°
C (Note 1,2) -4050mV
Reference Voltage APE1117AX-ADJ IOUT = 10mA, TJ=25°C, (VIN-VOUT)=1.5V 1.225 1.25 1.275 V
APE1117AX-15 IOUT = 10mA, TJ = 25°C, 3V≦VIN≦
12V 1.47 1.5 1.53 V
APE1117AX-18 IOUT = 10mA, TJ = 25°C, 3.3V≦VIN
≦12V 1.764 1.8 1.836 V
APE1117AX-25 IOUT = 10mA, TJ = 25°C, 4V≦VIN≦
12V 2.45 2.5 2.55 V
APE1117AX-33 IOUT = 10mA, TJ = 25°C, 4.8V≦VIN
≦12V 3.235 3.3 3.365 V
APE1117AX-50 IOUT = 10mA, TJ = 25°C, 6.5V≦VIN
≦12V 4.9 5 5.1 V
Ripple Rejection F=120Hz,COUT=10uF, APE1117AX-
XX, (VIN-VOUT) = 3V, IOUT = 1A -6070dB
Temperature Stability IOUT=10mA - 0.5 - %
3
Load Regulation
TEST CONDITION
Output Voltage
Note1: See thermal regulation specifications for changes in output voltage due to heating effects. Line and load regulation are measured at a
constant junction temperature by low duty cycle pulse testing. Load regulation is measured at the output lead = 1/18” from the package.
Note2: Line and load regulation are guaranteed up to the maximum power dissipation of 15W. Power dissipation is determined by the difference
between input and output differential and the output current. Guaranteed maximum power dissipation will not be available over the full input/output
range.
Note3: Quiescent current is defined as the minimum output current required in maintaining regulation. At 12V input/output differential the device is
r
n
r
l
if
h
rr
n
i
r
r
h
n 1
mA