BXB100 SERIES
Single output
[ 2 YEAR WARRANTY ]
• Industry standard footprint
• High power density (36.5W/in3)
• MTBF >1.4 million hours (Bellcore 332)
• Input voltage to ETS300-132-2
• Adjustable output voltage
• No minimum load required
• Separate case ground pin
• Undervoltage lockout (UVLO)
• UL, VDE and CSA safety approvals
The BXB100 Series are high power density DC/DC converters packaged in the
industry standard footprint (2.40 x 2.28 x 0.50 inches) to give designers optimum
choices when specifying for both new and replacement designs. Suitable for a
wide range of applications in nearly any industry, the BXB100 was particularly
designed with communication and distributed power applications in mind. Using
Bellcore 332, the MTBF is greater than 1,400,000 hours. Aluminum baseplate
technology with four threaded M3 inserts makes heatsink attachment and
optimum thermal management easy. The BXB100 series are approved to IEC950
by UL, CSA and VDE.
SPECIFICATION
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
PAGE 154
OUTPUT SPECIFICATIONS
Voltage adjustability 60% to 110%
Set point accuracy ±1.0%
Line regulation Low line to high line ±0.05%
Load regulation Full load to min. load ±0.10%
Minimum load 0%
Overshoot At turn-on and tur n-off None
Undershoot None
Ripple and noise 3.3V and 5V 75mV pk-pk,
(5Hz to 20MHz) 20mV rms
(See Note 1) 12V and 15V 100mV pk-pk,
30mV rms
Temperature coefficient ±0.01%/°C
Transient response ±2.0% max. deviation
(See Note 2) 170µs recovery
to within ±1.0%
Remote sense 0.5VDC transmission
line drop compensation
INPUT SPECIFICATIONS
Input voltage range 24Vin nominal 18 to 36VDC
48Vin nominal 36 to 75VDC
Input current No load 100mA max.
Remote OFF 20mA max.
Input current (max.) 48V models 4A max. @ Io max. and
(See Note 4) Vin = 0 to 75V
Input reflected ripple (See Note 6) 5mA pk-pk
Active low remote ON/OFF (See Note 7)
Logic compatibility Open collector ref to -input
ON 1.2VDC max.
OFF Open circuit
INPUT SPECIFICATIONS CONTINUED
Undervoltage lockout 24Vin: power up 17V
24Vin: power down 16V
48Vin: power up 34V
48Vin: power down 32.5V
Start-up time Power up 20ms
(See Note 8) Remote ON/OFF 20ms
EMC CHARACTERISTICS
Conducted emissions EN55022 (See Note 3) Level A
(See Note 3) FCC part 15 Level A
EN55022, CISPR22 Level A
GENERAL SPECIFICATIONS
Efficiency See table
Isolation voltage Input/case 1500VDC
Input/output 1500VDC
Output/case 1500VDC
Switching frequency Fixed 500kHz typ.
Approvals and VDE0805, EN60950, IEC950
standards (See Note 5) UL1950, CSA C22.2 No. 950
Case material Aluminum baseplate
with plastic case
Material flammability UL94V-0
Weight 110g (3.88oz)
MTBF Bellcore 332 1,400,000 hours
MIL-HDBK-217F 580,000 hours
@ 40°C, 100% load min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating case temp. -40°C to +100°C
Non-operating -55°C to +125°C
Altitude Operating 10,000 feet max.
Non-operating 40,000 feet max.
Vibration 5Hz to 500Hz 2.4G rms (approx.)
OUTPUT INPUT OVP OUTPUT OUTPUT OUTPUT EFFICIENCY REGULATION MODEL
POWER VOLTAGE VOLTAGE CURRENT CURRENT (TYP.) LINE LOAD NUMBER (7)
(MAX.) (MIN.) (MAX.)
66W 18-36VDC 4.3VDC 3.3V 0A 20A 77% ±0.05% ±0.1% BXB100-24S3V3FLT
100W 18-36VDC 6.5VDC 5V 0A 20A 82% ±0.05% ±0.1% BXB100-24S05FLT
100W 18-36VDC 14.5VDC 12V 0A 8.33A 85% ±0.05% ±0.1% BXB100-24S12FLT
100W 18-36VDC 17.5VDC 15V 0A 6.67A 85% ±0.05% ±0.1% BXB100-24S15FLT
66W 36-75VDC 4.3VDC 3.3V 0A 20A 78% ±0.05% ±0.1% BXB100-48S3V3FLT
100W 36-75VDC 6.5VDC 5V 0A 20A 83% ±0.05% ±0.1% BXB100-48S05FLT
100W 36-75VDC 14.5VDC 12V 0A 8.33A 86% ±0.05% ±0.1% BXB100-48S12FLT
100W 36-75VDC 17.5VDC 15V 0A 6.67A 86% ±0.05% ±0.1% BXB100-48S15FLT
Notes
1 Measured with 10µF tantalum capacitor and 1µF ceramic capacitor across
output.
2 di/dt = 0.1A/1µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 Io max. to 0.5 Io max.
3 Units should be characterised within systems. External components
required.
4 Input fusing is recommended based on surge current and maximum input
current.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Simulated source impedance of 12µH. 12µH inductor in series with +Vin.
7 Active high remote on/off option is available (standard product is active
low), designate with the suffix ‘FHT’ e.g. BXB100-48S05FHT. Consult
factory for further details and options.
8 Start-up into resistive load.
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 10401-3336-1095
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
ALL DIMENSIONS IN INCHES (mm)
Tolerance : x.xx ±0.02in. (0.51mm)
x.xxx ±0.010in. (0.254mm)
VIEW SHOWN
PIN SIDE UP
1.90
(48.26) 0.190 (4.83) ± 0.010 (0.25)
2 x Ø.080 (2.03) ± 0.002 (0.05)
4 x M3 x 0.5 Through
7 x Ø.040 (1.02) ±0.002 (0.05)
2.28 (57.91) Max.
0.700 (17.77)
1.000 (25.40)
1.400 (35.56)
2.000 (50.80)
0.190 (4.83) ±0.010 (0.25)
0.400 (10.16)
0.500 (12.69) ± 0.010 (0.25)
0.400 (10.16)
1.000 (25.40)
1.400 (35.56)
Vo(+) +SEN TRIM -SEN Vo (-)
VI(+) ON/OFF CASE VI (-)
0.200 (5.08) Min.
Length for all Input
and Output Pins
0.500 (12.70)
2.40 (60.96)
Max.
TRIM
UP
TRIM
DOWN
8
7
6
RT1
OR
RT2
PROTECTION
Short circuit protection Continuous, automatic recovery
Overvoltage protection Non-latching
Undervoltage protection Non-latching
Thermal protection 110°C baseplate,
automatic recovery
TELECOM SPECIFICATIONS
Central office interface A ETS300-132-2
66 to 100 Watt
Wide input DC/DC converters
DC/DC CONVERTERS |
66-100W DC/DC
PAGE 155
http://www.artesyn.com
PIN CONNECTIONS
PIN NUMBER FUNCTION
1+ Vin
2 Remote ON/OFF
3 Case
4- Vin
5 - Vout
6 - Sense
7 Trim
8 + Sense
9 + Vout
Data Sheet © Artesyn Technologies
®
2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: Application Note Simscope™
5
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed
by using the method shown below.
DS_BXB100_20000101.PDF