QSpan II
User Manual
Final Manual
May 16, 2013
GENERAL DISCLAIMER
Integrated Device Technology, Inc. reserves the right to make changes to its products or specifications at any time, without notice, in order to improve design or performance
and to supply the best possible product. IDT does not assume any responsibility for use of any circuitry described other than the circuitry embodied in an IDT product. The
Company makes no representations that circuitry described herein is free from patent infringement or other rights of third parties which may result from its use. No license is
granted by implication or otherwise under any patent, patent rights or other rights, of Integrated Device Technology, Inc.
CODE DISCLAIMER
Code examples provided by IDT are for illustrative purposes only and should not be relied upon for developing applications. Any use of the code examples below is completely
at your own risk . IDT MAKES NO R EPRESENTATIONS OR WARRANTIES OF ANY KIND CONCERNING THE NONINFRINGEMENT, QUAL ITY, SAFETY OR SUITABILITY
OF THE CODE, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICU-
LAR PURPOSE, OR NON-INFRINGEMENT. FURTHER, IDT MAKES NO REPRESEN TA TI ONS OR W ARRANTI ES AS T O THE TRUTH, ACCURA CY OR COMPLETENESS
OF ANY STATEMENTS, INFORMATION OR MATERIALS CONCERNING CODE EXAMPLES CONTAINED IN ANY IDT PUBLICATION OR PUBLIC DISCLOSURE OR
THAT IS CONTAINED ON ANY I DT I NTERNET SITE. IN NO EVENT WILL IDT BE LIABLE FOR A NY DIRECT, CONSEQUENTIAL, INCIDENTAL, INDIRECT, PUNITIVE OR
SPECIAL DAMAGES, HOWEVER THE Y MAY ARISE, AND EVEN IF IDT HAS BEEN PREVIOUSLY ADVISED ABOUT THE POSSIBILITY OF SUCH DAMAGES. The code
examples also may be subject to United States export control laws and may be subject to the export or import laws of other countries and it is your responsibility to comply with
any applicable laws or regulations.
LIFE SUPPORT POLICY
Integrated Device Technology's products are not authorized for use as critical components in life support devices or systems unless a specific written agreement pertaining to
such intended use is executed between the manufacturer and an officer of IDT.
1. Life support devices or systems are devices or systems which (a) are intended for surgical implant into the body or (b) support or sustain life and whose failure to perform,
when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user.
2. A critical component is any components of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device
or system, or to affect its safety or effectiveness.
IDT, the IDT logo, and Integrated Device Technology are trademarks or registered trademarks of Integrated Device Technology, Inc.
QSpan II User Manual 3
May 16, 2013
Revision History
Final Manual, May 16, 2013
This version was updated to include general improvements.
8091862.MA001.08, Final Manual, November 2009
This version of the document was rebranded as IDT. It does not include any technical
changes.
8091862.MA001.07, Final Manual, January 2007
Corrected the description of the BS field in the PBTI0_CTL, PBTI1_CTL,
QBSI0_AT, and QBSI1_AT registers (see “Register Map” on page 195).
Updated the Ordering Information section to indicate a reduction in the variety of
QSpan II parts available to customers (see “Ordering Information” on page 405).
8091862.MA001.06, Final Manual, September 2000
8091862.MA001.05, Final Manual, September 2000
8091862.MA001.04, Preliminary Manual, December 1999
8091862.MA001.03, Preliminary Manual, September 1999
8091862.MA001.02, Preliminary Manual, September 1999
8091862.MA001.01, Preliminary Manual, August 1999
Revision History
QSpan II User Manual4May 16, 20 13
QSpan II User Manual 5
May 16, 2013
Contents
Chapter 1: General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1.1 What is the QSpan II. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
1.1.1 QSpan II Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1.1.2 QSpan II verses QSpan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
1.2 Document Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1.2.1 Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1.2.2 Bit Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1.2.3 Numeric Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1.2.4 Topographic Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1.2.5 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
1.2.6 Document Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
1.3 Related Documentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Chapter 2: Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
2.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
2.2 The QBus Slave Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
2.3 The PCI Target Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.4 The IDMA Channel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.5 The DMA Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.6 The Register Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.7 The Interrupt Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
2.8 The EEPROM Channel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Chapter 3: The QBus Slave Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.2 QBus Slave Channel Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
3.2.1 QBus Slave Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3.2.1.1 QBus Data Parity Generation and Detection. . . . . . . . . . . . . . . . . . . . . . . . . 35
3.2.2 Qx-FIFO and Qr-FIFO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
3.2.3 PCI Master Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
3.3 Channel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Contents
QSpan II User Manual6May 16, 20 13
3.4 Address Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.4.1 Transaction Decoding and QBus Slave Images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3.4.1.1 MPC860 Cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
3.4.1.2 MC68360 Cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
3.4.1.3 M68040 Cycles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
3.4.2 PCI Bus Request . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
3.4.3 Address Translation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
3.4.4 Address Phase on the PCI Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
3.5 Data Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
3.5.1 Endian Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
3.5.2 Data Path. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
3.5.2.1 Writes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
3.5.2.2 Read Transactions — Burst and Single Cycle . . . . . . . . . . . . . . . . . . . . . . . . 48
3.5.2.3 Prefetched Reads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
3.5.2.4 Delayed Reads and PCI Transaction Ordering . . . . . . . . . . . . . . . . . . . . . . . . 49
3.5.3 PCI Target Channel Reads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
3.5.4 Parity Monitoring by PCI Master Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
3.6 Termination Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
3.6.1 Posted Write Termination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
3.7 PCI Master Retry Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Chapter 4: The PCI Target Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4.2 PCI Target Channel Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
4.2.1 PCI Target Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
4.2.2 Px-FIFO and Pr-FIFO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
4.2.3 QBus Master Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
4.2.3.1 QBus Data Parity Generation and Detection . . . . . . . . . . . . . . . . . . . . . . . . . 58
4.3 Channel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
4.4 Address Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
4.4.1 Transaction Decoding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
4.4.2 Address Translation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
4.4.3 Transaction Codes on the QBus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
4.4.4 PCI BIOS Memory Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
4.4.4.1 Block Size and PCI Address Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
4.4.4.2 Base Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
4.5 Data Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
4.5.1 Endian Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
4.5.1.1 Write Cycle Mapping for PCI Target Channel. . . . . . . . . . . . . . . . . . . . . . . . 66
4.5.1.2 Read Cycle Mapping for PCI Target Channel . . . . . . . . . . . . . . . . . . . . . . . . 68
4.5.2 Data Path. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
4.5.2.1 Posted Writes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Contents
QSpan II User Manual 7
May 16, 2013
4.5.2.2 Delayed Writes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
4.5.2.3 Single Read Transactions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
4.5.2.4 Prefetched Read Transactions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
4.5.3 Parity Monitoring by PCI Target Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
4.6 Reads and PCI Transaction Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
4.6.1 Transaction Ordering Disable Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
4.7 QBus Arbitration and Sampling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
4.7.1 MC68360 Bus Arbitration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
4.7.2 MPC860 Bus Arbitration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
4.7.3 M68040 Bus Arbitration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.8 Terminations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.8.1 QBus Master Module Terminations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.8.2 MC68360 Cycle Terminations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
4.8.3 MPC860 Cycle Terminatio ns. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
4.8.4 M68040 Cycle Terminations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
4.8.5 Terminations driven by the PCI Target Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
4.8.5.1 Target-Disconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
4.8.5.2 Target-Retry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
4.8.5.3 Target-Abort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
4.8.6 Terminations of Posted Writes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Chapter 5: The IDMA Channel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
5.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
5.2 PCI Read Transactions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
5.2.1 Data Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
5.3 PCI Write Transactions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
5.3.1 Data Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
5.4 TC[3:0] Encoding with MPC860 IDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
5.5 IDMA Status Tracking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
5.6 IDMA Errors, Resets, and Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
5.7 IDMA Endian Issues. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Chapter 6: The DMA Channel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
6.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
6.2 DMA Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
6.2.1 Burst Cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
6.2.2 DMA Cycles on QBus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
6.3 Direct Mode DMA Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
6.3.1 Initiating a Direct Mode Transfer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
6.3.2 Terminating a Direct Mode Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Contents
QSpan II User Manual8May 16, 20 13
6.4 Linked List Mode DMA Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
6.4.1 Initiating a Linked List Mode DMA Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
6.4.2 Terminating a Linked List Mode DMA Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Chapter 7: The Register Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
7.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
7.2 Register Access Fairness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
7.3 Register Access from the PCI Bus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
7.4 Register Access from the QBus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
7.4.1 Examples of QBus Register Accesses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
7.4.2 PCI Configuration Cycles Generated from the QBus. . . . . . . . . . . . . . . . . . . . . . . . . 108
7.4.3 Address Phase of PCI Configuration Cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
7.4.3.1 Data Phase of PCI Configuration Cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
7.4.4 Interrupt Acknowledge Cycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
7.5 Register Access Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
7.6 Mailbox Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Chapter 8: The Interrupt Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
8.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
8.2 Hardware-Triggered Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
8.3 Software-Triggered Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
8.3.1 Interrupt Generation due to PCI Configuration Register Status Bits . . . . . . . . . . . . . 118
8.4 Interrupt Acknowledge Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
8.5 Disabling PCI Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
Chapter 9: The EEPROM Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
9.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
9.2 EEPROM Configuration and Plug and Play Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . 123
9.3 EEPROM I2C Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
9.4 Mapping of EEPROM Bits to QSpan II Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
9.5 Programming the EEPROM from the QBus or PCI Bus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
9.5.1 Writing to the EEPROM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
9.5.2 Reading from the EEPROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
9.6 EEPROM Access. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
9.7 Vital Product Data Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
9.7.1 Reading VPD Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
9.7.2 Writing VPD Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Chapter 10: I2O Messaging Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
10.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
10.2 Inbound Messaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
10.3 Outbound Messaging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
10.4 I2O Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Contents
QSpan II User Manual 9
May 16, 2013
10.5 Summary of I2O Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
10.5.1 Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
10.5.1.1 Inbound I2O Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
10.5.1.2 I2O Outbound Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
10.6 I2O Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
Chapter 11: PCI Bus Arbiter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
11.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
11.2 Arbitration Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
11.3 Bus Parking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
Chapter 12: CompactPCI Hot Swap Friendly Support . . . . . . . . . . . . . . . . . . . 143
12.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
12.2 Hot Swapping with the QSpan II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
12.3 CompactPCI Hot Swap Card Insertion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
12.4 CompactPCI Hot Swap Card Extraction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Chapter 13: PCI Power Management Event Support. . . . . . . . . . . . . . . . . . . . . 151
13.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
13.2 Power Management Event (PME#) Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
Chapter 14: Reset Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
14.1 Types of Resets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
14.1.1 PCI Transactions during QBus Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
14.1.2 IDMA Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
14.1.3 Clocking and Resets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
14.2 Configuration Options at Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
14.2.1 PCI Bus Master Reset Option. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
14.2.2 QBus Master and Slave Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
14.2.3 EEPROM Loading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
14.2.4 PCI Register Access Option. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
14.2.5 PCI Bus Arbitration Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
Chapter 15: Hardware Implementation Issues . . . . . . . . . . . . . . . . . . . . . . . . . . 157
15.1 Test Mode Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
15.2 JTAG Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
15.3 Decoupling Capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
Chapter 16: Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
16.1 Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
16.2 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
16.3 MC68360 Signals: QUICC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
16.4 MPC860 Signals: PowerQUICC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
16.5 M68040 Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Contents
QSpan II User Manual10 May 16, 20 13
16.6 PCI Bus Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
16.7 Hot Swap Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
16.8 Miscellaneous Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
16.9 JTAG Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
Chapter 17: Signals and DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
17.1 Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
17.2 Packaging and Voltage Level Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
17.3 Signals and DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
17.4 Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
Appendix A: Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
A.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
A.2 Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
A.3 Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
A.4 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Appendix B: Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
B.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
B.2 Timing Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
B.3 Wait State Insertion — QBus Slave Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
B.4 Timing Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
B.4.1 QBus Interface — MC68360 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
B.4.2 QBus Master Cycles — MC68360. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
B.4.2.1 QBus Slave Cycles — MC68360. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
B.4.2.2 QBus IDMA Cycles — MC68360. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322
B.4.3 QBus Interface — MPC860 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330
B.4.3.1 QBus Master Cycles — MPC860. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330
B.4.3.2 QBus Slave Cycle — MPC860 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
B.4.3.3 QBus IDMA Cycles — MPC860. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
B.4.4 QBus Interface — M68040. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345
B.4.4.1 QBus Master Cycles — M68040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
B.4.4.2 QBus Slave Cycles — M68040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
B.4.5 Interrupts and Resets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355
B.4.6 Reset Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
Appendix C: Typical Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359
C.1 MC68360 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359
C.1.1 Hardware Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359
C.1.1.1 Clocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359
C.1.1.2 Resets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360
C.1.1.3 Memory Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361
C.1.1.4 QBus Direct Connects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
Contents
QSpan II User Manual 11
May 16, 2013
C.1.1.5 Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
C.1.1.6 PCI Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
C.1.1.7 EEPROM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
C.1.1.8 Reset Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
C.1.1.9 Unused Inputs Requiring Pull-Ups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
C.1.1.10 No Connects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
C.1.1.11 JTAG Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
C.1.1.12 Address Multiplexing for DRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
C.1.2 Software Issues. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
C.1.3 MC68360 Slave Mode Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
C.2 MPC860 Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365
C.2.1 Hardware Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366
C.2.1.1 Clocking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366
C.2.1.2 Resets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367
C.2.1.3 Memory Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368
C.2.1.4 QBus Direct Connects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368
C.2.1.5 Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369
C.2.1.6 PCI Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369
C.2.1.7 EEPROM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369
C.2.1.8 Reset Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369
C.2.1.9 Unused Inputs Requiring Pull-Ups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
C.2.1.10 No Connects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
C.2.1.11 JTAG Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
C.2.1.12 Bused Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
C.2.1.13 Address Multiplexing for DRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
C.2.1.14 Software Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371
C.3 M68040 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372
C.3.1 Hardware Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
C.3.1.1 Clocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
C.3.1.2 Resets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
C.3.1.3 Address Decoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
C.3.1.4 QBus Direct Connects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
C.3.1.5 Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
C.3.1.6 PCI Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375
C.3.1.7 EEPROM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375
C.3.1.8 Reset Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375
C.3.1.9 Unused Inputs Requiring Pull-Ups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376
C.3.1.10 No Connects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376
C.3.1.11 JTAG Signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376
Contents
QSpan II User Manual12 May 16, 20 13
Appendix D: Software Initialization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
D.1 Miscellaneous Control Register Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 378
D.2 QBus Slave Channel Initialization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 380
D.3 Register Access from the PCI Bus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 381
D.4 PCI Target Channel Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 381
D.5 Error Logging of Posted Transactions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383
D.6 IDMA/DMA Channel Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
D.7 Interrupt Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
D.8 Generation of PCI Configuration and IACK Cycles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385
D.9 EEPROM and VPD Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 386
D.10 I2O Messaging Unit Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 386
D.11 PCI Expansion ROM Implementation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387
Appendix E: Endian Mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
E.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
E.2 Big-Endian System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390
E.3 Little-Endian System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391
E.4 Endian Mapping Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 392
E.4.1 Address Invariance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 392
E.4.2 Data Invariance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393
E.4.3 Combined Method. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393
Chapter 18: Operating and Storage Conditions . . . . . . . . . . . . . . . . . . . . . . . . . 395
18.1 Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395
18.2 Operating Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396
18.3 Thermal Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396
Appendix F: Mechanical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
F.1 Mechanical Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
F.1.1 256 PBGA — 17 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
F.1.1.1 PBGA Notes — 17 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
F.1.2 256 PBGA — 27 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401
F.1.2.1 PBGA Notes — 27 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402
Appendix G: Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405
G.1 Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405
G.2 Part Numbering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411
QSpan II User Manual 13
May 16, 2013
List of Figures
Figure 1: QSpan II Bridging PCI and Processor Buses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 2: QSpan II Functional Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 3: QBus Slave Channel — Functional Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 4: Address Generator for QBus Slave Channel Transfers . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 5: PCI Target Channel — Functional Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Figure 6: Address Generator for PCI Target Channel Transfers. . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 7: IDMA Channel — Functional Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Figure 8: DMA Channel — Functional Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Figure 9: Linked List DMA Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Figure 10: Register Channel — Functional Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Figure 11: QSpan II Control and Status Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Figure 12: QCSR Access from the QBus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Figure 13: Example of a Register-Access Synchronization Problem . . . . . . . . . . . . . . . . . . . . . . . 111
Figure 14: Interrupt Channel — Functional Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Figure 15: EEPROM Channel — Functional Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Figure 16: Sequential Read from EEPROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Figure 17: I2O Messaging Unit — Functional Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Figure 18: I2O Implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Figure 19: PCI Bus Arbiter — Functional Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Figure 20: PCI Bus Arbiter — Arbitration Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Figure 21: CompactPCI Hot Swap — Functional Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Figure 22: Hot Swap Card Insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Figure 23: Hot Swap Card Extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Figure 24: Reference Voltages for AC Timing Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Figure 25: QCLK Input Timing — MC68360 CLKO1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
Figure 26: QBus Arbitration — MC68360 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315
Figure 27: Single Read — QSpan II as MC68360 Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
Figure 28: Single Write — QSpan II as MC68360 Master. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317
Figure 29: Delayed Single Read — QSpan II as MC68360 Slave . . . . . . . . . . . . . . . . . . . . . . . . . 318
Figure 30: Single Write — QSpan II as MC68360 Slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
List of Figures
QSpan II User Manual14 May 16, 20 13
Figure 31: Register Read — QSpan II as MC68360 Slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320
Figure 32: Register Write — QSpan II as MC68360 Slave. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321
Figure 33: MC68360 DREQ_ Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322
Figure 34: MC68360 IDMA Read — Single Address, Standard Terminations . . . . . . . . . . . . . . . 323
Figure 35: MC68360 IDMA Write — Single Address, Standard Terminations . . . . . . . . . . . . . . . 324
Figure 36: MC68360 IDMA Read — Single Address, Fast Termination . . . . . . . . . . . . . . . . . . . . 325
Figure 37: MC68360 IDMA Write — Single Address, Fast Termination . . . . . . . . . . . . . . . . . . . 325
Figure 38: MC68360 IDMA Read — Dual Address, Standard Termination . . . . . . . . . . . . . . . . . 326
Figure 39: MC68360 IDMA Write — Dual Address, Standard Termination . . . . . . . . . . . . . . . . . 327
Figure 40: MC68360 IDMA Read — Dual Address, Fast Termination . . . . . . . . . . . . . . . . . . . . . 328
Figure 41: MC68360 IDMA Read — Dual Address, Fast Termination . . . . . . . . . . . . . . . . . . . . . 329
Figure 42: QBus Arbitration — MPC860 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330
Figure 43: Single Read — QSpan II as MPC860 Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
Figure 44: Single Write — QSpan II as MPC860 Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332
Figure 45: Burst Read — QSpan II as MPC860 Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
Figure 46: Aligned Burst Write — QSpan II as MPC860 Master. . . . . . . . . . . . . . . . . . . . . . . . . . 334
Figure 47: Single Read — QSpan II as MPC860 Slave. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
Figure 48: Single Write — QSpan II as MPC860 Slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
Figure 49: Burst Read — QSpan II as MPC860 Slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337
Figure 50: Burst Write — QSpan II as MPC860 Slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
Figure 51: Register Read — QSpan II as MPC860 Slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339
Figure 52: Register Write — QSpan II as MPC860 Slave. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340
Figure 53: MPC860 DREQ_ Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
Figure 54: MPC860 IDMA Read — Single Address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
Figure 55: MPC860 IDMA Write — Single Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
Figure 56: MPC860 IDMA Read — Dual Address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344
Figure 57: MPC860 IDMA Write — Dual Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345
Figure 58: QCLK Input Timing — M68040 BCLK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345
Figure 59: QBus Arbitration — M68040. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
Figure 60: Single Read — QSpan II as M68040 Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
Figure 61: Single Write — QSpan II as M68040 Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
Figure 62: Single Read — QSpan II as M68040 Slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
Figure 63: Single Write — QSpan II as M68040 Slave. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
Figure 64: Delayed Burst Read — QSpan II as M68040 Slave. . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
Figure 65: Posted Burst Write — QSpan II as M68040 Slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352
Figure 66: Register Reads — QSpan II as M68040 Slave. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353
Figure 67: Register Write — QSpan II as M68040 Slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354
Figure 68: Reset from PCI Interface — RST# related to RESETO_. . . . . . . . . . . . . . . . . . . . . . . . 355
Figure 69: Software Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355
List of Figures
QSpan II User Manual 15
May 16, 2013
Figure 70: INT# Interrupt to QINT_ Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355
Figure 71: PERR# Interrupt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355
Figure 72: SERR# Interrupt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 356
Figure 73: QINT_ Interrupt to INT# Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 356
Figure 74: Reset Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
Figure 75: MC68360 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360
Figure 76: MPC860 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365
Figure 77: MPC860/QSpan II Clocking Scheme Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366
Figure 78: Example Code for Exe cuting an MPC860 Delay Loop. . . . . . . . . . . . . . . . . . . . . . . . . 367
Figure 79: M68040 Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372
Figure 80: Big-Endian System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390
Figure 81: Little-Endian System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391
Figure 82: Address Invariant Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 392
Figure 83: Data Invariant Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393
Figure 84: 256 PBGA, 17 mm — Top and Side Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
Figure 85: 256 PBGA, 17 mm — Bottom View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401
Figure 86: 256 PBGA, 27 mm — Top and Side Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402
Figure 87: 256 PBGA, 27 mm — Bottom View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403
List of Figures
QSpan II User Manual16 May 16, 20 13
QSpan II User Manual 17
May 16, 2013
List of Tables
Table 1: QSpan II New Features and Functional Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . 26
Table 2: Reset Options for QBus Slave Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 3: Address Fields for QBus Slave Image. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Table 4: Control Fields for QBus Slave Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Table 5: Translation of QBus Address to PCI Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Table 6: Command Type Encoding for Transfer Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Table 7: Translation from QBus Transaction to PCI Transaction Type . . . . . . . . . . . . . . . . . . . . 44
Table 8: Little-Endian QBus Slave Channel Cycle Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Table 9: Big-Endian QBus Slave Channel Cycle Mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Table 10: Translation of Cycle Termination from PCI Bus to QBus. . . . . . . . . . . . . . . . . . . . . . . . 51
Table 11: MC68360 Cycle Terminations of QBus Slave Module. . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table 12: MPC860 Cycle Terminations of QBus Slave Module. . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table 13: M68040 Cycle Terminations of QBus Slave Module . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table 14: QBus Slave Channel Error Responses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Table 15: Reset Options for QBus Master and Slave Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Table 16: Address Fields for PCI Target Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Table 17: Control Fields for PCI Target Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Table 18: Translation of PCI Bus Address to QBus Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Table 19: Little-Endian PCI Target Write Cycle Mapping — 32-Bit QBus Port . . . . . . . . . . . . . . 67
Table 20: Big-Endian PCI Target Write Cycle Mapping — 32-Bit QBus Port. . . . . . . . . . . . . . . . 67
Table 21: Little-Endian PCI Target Read Cycle Mapping — 32-Bit QBus Port. . . . . . . . . . . . . . . 69
Table 22: Big-Endian PCI Target Read Cycle Mapping — 32-Bit QBus Port . . . . . . . . . . . . . . . . 69
Table 23: Little-Endian PCI Target Read Cycle Mapping — 16-Bit QBus Port. . . . . . . . . . . . . . . 70
Table 24: Big-Endian PCI Target Read Cycle Mapping — 16-Bit QBus Port . . . . . . . . . . . . . . . . 70
Table 25: Little-Endian PCI Target Read Cycle Mapping — 8-Bit QBus Port. . . . . . . . . . . . . . . . 71
Table 26: Big-Endian PCI Target Read Cycle Mapping — 8-Bit QBus Port . . . . . . . . . . . . . . . . . 71
Table 28: MPC860 Cycle Terminations of QBus Master Module. . . . . . . . . . . . . . . . . . . . . . . . . . 79
Table 29: M68040 Cycle Terminations of QBus Master Module . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Table 27: MC68360 Cycle Terminations of QBus Master Module. . . . . . . . . . . . . . . . . . . . . . . . . 79
Table 30: Translation of Cycle Termination from QBus to PCI Bus. . . . . . . . . . . . . . . . . . . . . . . . 82
List of Tables
QSpan II User Manual18 May 16, 20 13
Table 32: IDMA Interrupt Source, Enabling, Mapping, Status and Clear bits. . . . . . . . . . . . . . . . . 90
Table 31: QSpan II’s Response to IDMA Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Table 34: 16-Bit Big-Endian IDMA Cycle Mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Table 35: 32-Bit Little-Endian IDMA Cycle Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Table 36: 32-Bit Big-Endian IDMA Cycle Mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Table 33: 16-Bit Little Endian IDMA Cycle Mapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Table 37: PCI Memory Cycle Access to bits 15-08 of the PCI_CLASS register . . . . . . . . . . . . . 106
Table 38: Big-Endian QBus Access to bits 15-08 of the PCI_CLASS register . . . . . . . . . . . . . . . 108
Table 39: Little-Endian QBus Access to bits 15–08 of the PCI_CLASS register . . . . . . . . . . . . . 108
Table 40: PCI AD[31:16] lines asserted as a function of DEV_NUM field . . . . . . . . . . . . . . . . . 110
Table 41: Mapping of Hardware-Initiated Interrupts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Table 42: Interrupt Source, Enabling, Mapping, Status and Clear bits . . . . . . . . . . . . . . . . . . . . . 116
Table 43: Software Interrupt Mapping, Status and Source bits . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Table 44: Destination of EEPROM Bits Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Table 45: Insertion Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
Table 46: Extraction Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Table 47: Hardware Reset Mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
Table 48: Reset Options for QBus Master and Slave Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
Table 49: Test Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Table 50: QBus Signal Names Compared to Motorola Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Table 51: MC68360/MPC860 Encoding for the SIZ[1:0] Signal. . . . . . . . . . . . . . . . . . . . . . . . . . 169
Table 52: M68040 Encoding for the SIZ[1:0] Signal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
Table 53: Non-PCI DC Electrical Characteristics (VDD ±5%) . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
Table 54: 3.3V PCI I/O Signaling AC/DC Characteristics (VDD ±5%). . . . . . . . . . . . . . . . . . . . . 179
Table 55: 5V PCI I/O Signaling AC/DC Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . . 180
Table 56: Pin List for QSpan II Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
Table 57: PCI Bus Address/Data Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
Table 58: QBus Address Pins. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
Table 59: QBus Data Pins. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Table 60: External Request and Grant Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Table 61: Pin Assignments for Power (VDD). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Table 62: Voltage Required to be Applied to VH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Table 63: Pin Assignments for Ground (VSS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Table 64: No-connect Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Table 65: Pinout of 17x17 mm Package. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
Table 66: Pinout of 27x27 mm Package. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Table 67: Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Table 68: I2O Memory Map — Lower 4K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
Table 69: PCI Configuration Space ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
List of Tables
QSpan II User Manual 19
May 16, 2013
Table 70: PCI Configuration Space Control and Status Register . . . . . . . . . . . . . . . . . . . . . . . . . 201
Table 71: PCI Configuration Class Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
Table 72: PCI Configuration Miscellaneous 0 Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Table 73: PCI Configuration Base Address for Memory Register . . . . . . . . . . . . . . . . . . . . . . . . 206
Table 74: I20 Base Address Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
Table 75: PCI Configuration Base Address for Target 0 Register. . . . . . . . . . . . . . . . . . . . . . . . . 208
Table 76: PCI Address Lines Compared as a Function of Block Size. . . . . . . . . . . . . . . . . . . . . . 209
Table 77: PCI Configuration Base Address for Target 1 Register. . . . . . . . . . . . . . . . . . . . . . . . . 210
Table 78: PCI Address Lines Compared as a Function of Block Size. . . . . . . . . . . . . . . . . . . . . . 211
Table 79: PCI Configuration Subsystem ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
Table 80: PCI Configuration Expansion ROM Base Address Register. . . . . . . . . . . . . . . . . . . . . 213
Table 81: Writable BA bits as a function of Block Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Table 82: PCI Capabilities Pointer Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Table 83: PCI Configuration Miscellaneous 1 Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
Table 84: PCI Power Management Capabilities Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
Table 85: PCI Power Management Control and Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . 218
Table 86: CompactPCI Hot Swap Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
Table 87: PCI Vital Product Data Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
Table 88: PCI VPD Data Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
Table 89: PCI Bus Target Image 0 Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
Table 90: PCI Bus Target Image 0 Address Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
Table 91: PCI Address Lines Compared as a Function of Block Size. . . . . . . . . . . . . . . . . . . . . . 225
Table 92: PCI Bus Target Image 1 Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
Table 93: PCI Bus Target Image 1 Address Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
Table 94: PCI Address Lines Compared as a Function of Block Size. . . . . . . . . . . . . . . . . . . . . . 229
Table 95: PCI Bus Expansion ROM Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
Table 96: PCI Address Lines Compared as a Function of Block Size. . . . . . . . . . . . . . . . . . . . . . 231
Table 97: PCI Bus Error Log Control and Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
Table 98: PCI Bus Address Error Log Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
Table 99: PCI Bus Data Error Log Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
Table 100: I2O Control and Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
Table 101: I2O Inbound Free_List Top Pointer Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
Table 102: I2O Inbound Free_List Bottom Pointer Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
Table 103: I2O Inbound Post_List Top Pointer Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
Table 104: I2O Inbound Post_List Bottom Pointer Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
Table 105: I2O Outbound Free_List Top Pointer Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
Table 106: I2O Outbound Free_List Bottom Pointer Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
Table 107: I2O Outbound Post_List Top Pointer Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
Table 108: I2O Outbound Post_List Bottom Pointer Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
List of Tables
QSpan II User Manual20 May 16, 20 13
Table 109: IDMA Control and Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
Table 110: IDMA/DMA PCI Address Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
Table 111: IDMA/DMA Transfer Count Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
Table 112: DMA QBus Address Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Table 113: DMA Control and Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
Table 114: DMA Command Packet Pointer Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
Table 115: Configuration Address Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
Table 116: PCI AD[31:16] lines asserted as a function of DEV_NUM field . . . . . . . . . . . . . . . . . 257
Table 117: Configuration Data Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
Table 118: IACK Cycle Generator Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
Table 119: Interrupt Status Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
Table 120: Interrupt Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
Table 121: Interrupt Direction Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
Table 122: Interrupt Control Register 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269
Table 123: Mailbox 0 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
Table 124: Mailbox 1 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
Table 125: Mailbox 2 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
Table 126: Mailbox 3 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
Table 127: Miscellaneous Control and Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274
Table 128: Master/Slave Mode — MSTSLV field. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
Table 129: EEPROM Control and Status Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
Table 130: Miscellaneous Control 2 Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
Table 131: PCI Bus Arbiter Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281
Table 132: Parked PCI Master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
Table 133: QBus Slave Image 0 Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
Table 134: QSpan II Response to a Single-Read Cycle Access. . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Table 135: QSpan II Response to a Burst-Read Cycle Access. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Table 136: QSpan II Response to a Single-Write Cycle Access . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Table 137: QSpan II Response to a Burst-Write Cycle Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Table 138: QBus Slave Image 0 Address Translation Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285
Table 139: Address Lines Translated as a Function of Block Size . . . . . . . . . . . . . . . . . . . . . . . . . 286
Table 140: QBus Slave Image 1 Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
Table 141: QSpan II Response to a Single-Read Cycle Access. . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
Table 142: QSpan II Response to a Burst-Read Cycle Access. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
Table 143: QSpan II Response to a Single-Write Cycle Access . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
Table 144: QSpan II Response to a Burst-Write Cycle Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
Table 145: QBus Slave Image 1 Address Translation Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
Table 146: QBus Address Lines Compared as a function of Block Size . . . . . . . . . . . . . . . . . . . . . 290
Table 147: QBus Error Log Control and Status Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
List of Tables
QSpan II User Manual 21
May 16, 2013
Table 148: QBus Address Error Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
Table 149: QBus Data Error Log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
Table 150: I20 Outbound Post_List Interrupt Status Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
Table 151: I20 Outbound Post_List Interrupt Mask Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
Table 152: I2O Inbound Queue Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
Table 153: I2O Outbound Queue Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297
Table 154: Timing Parameters for MC68360 Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
Table 155: Timing Parameters for MPC860 Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
Table 156: Timing Parameters for M68040 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
Table 157: Timing Parameters for Interrupts and Resets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313
Table 158: Timing Parameters for Reset Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313
Table 159: Direction of QBus Signals During MC68360 IDMA Cycles . . . . . . . . . . . . . . . . . . . . 322
Table 160: Direction of QBus Signals During MPC860 IDMA Cycles . . . . . . . . . . . . . . . . . . . . . 341
Table 161: Summary of the QSpan II’s Miscellaneous Control Register . . . . . . . . . . . . . . . . . . . . 378
Table 162: Summary of the QSpan II’s Miscellaneous Control Register 2. . . . . . . . . . . . . . . . . . . 379
Table 163: PCI Arbiter Control Register Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 380
Table 164: QBus Slave Channel Programming Summa ry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 380
Table 165: Register Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 381
Table 166: PCI Target Image Programming Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 381
Table 167: QBus Error Logging Programming Sum mary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383
Table 168: PCI Bus Error Logging Programming Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383
Table 169: IDMA/DMA Channel Programming Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
Table 170: PCI Configuration and IACK Cycle Programming Summary. . . . . . . . . . . . . . . . . . . . 385
Table 171: PCI Expansion ROM programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387
Table 172: Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 395
Table 173: 3.3 Volt Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396
Table 174: 3.3 Volt Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396
Table 175: Junction to Ambient Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397
Table 176: 256 PBGA — 17 mm Packaging Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
Table 177: 256 PBGA — 27 mm Packaging Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401
Table 178: Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405
List of Tables
QSpan II User Manual22 May 16, 20 13
QSpan II User Manual 23
May 16, 2013
Chapter 1: General Information
This chapter describes the main functions and features of the QSpan II. It also discusses
general document elements and t echnical support informati on. The following topics are
discussed:
“What is the QSpan II” on page 24
“Document Conven tio ns” on page 27
“Motorola MPC860 (PowerQUICC) User’s Manual” on page 28
“Related Documentation” on page 28
Chapter 1: General Information
QSpan II User Manual24 May 16, 20 13
1.1 What is the QSpan II
The QSpan II™ chip is a member of IDT’ s growing family of PCI bus-bridging devices.
QSpan II enables board designers to bring PCI-based embedded products to market
faster, for less cost, and with high performance.
Developed a s part of an ongoing strategic relationship with Motorola®, QSpan II is
designed to gluelessly bridge the MC68360 (QUICC™), the MPC860
(PowerQUICC™), other MPCxxx devices, and the M68040/M68060 to PCI (see
Figure 1). With additional glue logic, QSpan II can also be connected to lower-end
communications controllers and processors, such as the MC68302 and MC68030.
Figure 1: QSpan II Bridging PCI and Processor Buses
QSpan II
Motorola
MC68360
MPC860
MPC850
M68040
MPC801
MPC821
MC68302
MC68030
PCI
Chapter 1: General Information
QSpan II User Manual 25
May 16, 2013
1.1.1 QSpan II Features
QSpan II has the following features:
A direct-connect interface to the PCI bus for Motorola’s MC68360 and MPC860
communications controllers, and the M68040 Host processor.
QSpan compatible
Support for up to 50 MHz MPC8xx bus frequencies (ind ustrial temperature range:
-40°C to 85°C)
Available in two, low thermal resistance packages: 17 mm x 17 mm PBGA; and
27 mm x 27 mm PBGA. Both packages have 3.3V power requirement s and are 5V
tolerant
32-bit PCI interface
Integrated PCI bus arbiter
Flexible, high performa nce DMA engine which operates in both Direct and
Scatter/Gather mode
Five FIFO buffers for multiple transactions in both directions
Accepts and generates burst reads and writes on the PCI bus
MPC860 UPM-compliant burst reads and writes as processor bus master
Separate channel supports MC68360 and MPC860 IDMA
Flexible address space mapping and translation between the PCI and processor
buses
Programmable endian -byte ordering
Serial EEPROM interface for Plug and Play compatibility
Support for PCI and processor bus operation at different clock frequencies
IEEE 1149.1 JTAG boundary scan support
CompactPCI Hot Swap Friendly support
Sup port f or Vital Product Data and Power Management
•I
2O Messaging Unit
Mailbox registers for user-designed message passing
Chapter 1: General Information
QSpan II User Manual26 May 16, 20 13
1.1.2 QSpan II verses QSpan
The following table summarizes the main QSpan II features that were unavailable in the
QSpan device.
Table 1: QSpan II New Features and Functional Enhancements
Description See
Features
DMA Channel “The DMA Channel”
on page 93
Vital Product Data (PCI Local Bus Specification 2.2 compatible) “Vital Product Data
Support” on page 128
I2O Messaging Unit “I2O Messaging
Unit” on page 131
Integrated PCI Bus Arbiter “PCI Bus Arbiter” on
page 139
CompactPCI Hot Swap Friendly “CompactPCI Hot
Swap Friendly
Support” on page 143
PCI Bus Power Management (PCI Bus Power Management Interface Specification 1.1
compatible) “PCI Power
Management Event
Support” on page 151
Functional Enhancements
Support for QBus Data Parity Generation and Detection “QBus Data Parity
Generation and
Detection” on page 35
Performance Improvement for QBus Posted Write Transfers “Writes” on page 46
Support for prefetching through the QBus Slave Channel “Prefetched Reads”
on page 48
Option to Keep Bus Busy (BB_) asserted on Back-to-Back Transfers on the QBus during
PCI target cycles “Bursting on the
QBus” on page 73
Option to use a different prefetch count in the PCI Target Channel based on the Target
Image “Prefetched Read
Transactions” on
page 74
MPC860 UPM-compliant burst reads and writes as processor bus master “Burst Cycles” on
page 96
Chapter 1: General Information
QSpan II User Manual 27
May 16, 2013
1.2 Document Conventions
1.2.1 Signals
Signals are either active high or active low. Active low signals are defined as true
(asserted) when they are at a logic low. Similarly, active high signals are defined as true
at a logic high. Signals are considered asserted when active and negated when inactive,
irrespective of voltage levels. For voltage levels, the use of 0 indicates a low voltage
while a 1 indicates a high voltage.
The following signal conventions are used:
SIGNAL#: Active low signals on the PCI bus interface.
SIGNAL_: Active low signals on the Host processor bus interface.
1.2.2 Bit Ordering
This document adopts the convention that the most significant bit is always the largest
number (also referred to as Little-Endian bit ordering). For example, the PCI
address/data bus consists of AD[31:0], where AD[31] is the most significant bit and
AD[0] is the least-significant bit of the field.
1.2.3 Numeric Conventions
The following numeric conventions are used:
Hexadecimal numbers are denoted by the prefix 0x. For example, 0x004.
Binary numbers are denoted by the suffix b. For example, 010b.
1.2.4 Topographic Conventions
The following typographic conventions are used:
Italic type is used for the following purposes:
Book titles: For example, PCI Local Bus Specification (Revision 2.2).
Important terms: For example, when a devic e is granted access to the PCI bus
it is called the bus master.
Undefined values: For example, the device supports two or three ports
depending on the setting of the PCI_Dx register.
Courier type is used to represent a file na me or text that appears on a computer
display. For example, “run loadext.exe by typing it at a command prompt.”
Chapter 1: General Information
QSpan II User Manual28 May 16, 20 13
1.2.5 Symbols
1.2.6 Document Status
IDT technical documentation is classified as either Advance, Preliminary, or Final.
These classifications are briefly explained:
Advance: The Advance manual contains information that is subject to change. The
Advance manual exists until device prototypes are available. This type of manual
can be downloaded from our website.
Preliminary: The Preliminary manual contains information about a device that is
near production-ready, and is revised on an “as needed” basis. The Preliminary
manual exists until the device is released to production. This type of manual can be
downloaded from our website.
Formal: The Formal manual contains information about a customer-ready device.
This type of manual can be downloaded from our website.
1.3 Related Documentation
Before you read this manual, you should be familiar with the following:
PCI Local Bus Specification (Revision 2.2)
CompactPCI Hot Swap Specification (Revision 1.0)
CompactPCI Specification (Revision 2.1)
PCI Bus Power Management Interface Specification, (Revision 1.1)
Intelligent I/O Architecture Specification (Revision 1.5)
QSpan II/MPC860 CompactPCI Evaluation Board Manual (6091862_MA001)
QSpan II Software Development Kit Manual (6091862_MA002)
Motorola M68040 Users Manua l
Motorola MC68360 Users Manual
Motorola MPC860 (PowerQUICC) Users Manual
This symbol directs the reader to useful information or suggestions.
This symbol alerts the reader to procedures or operating levels which may
result in misuse or damage to the product.
This symbol alerts the reader to an initialization process that must be
performed as a minimum to access the required channel or interface.
QSpan II User Manual 29
May 16, 2013
Chapter 2: Functional Overview
This chapter briefly discusses the main functional components (also referred to a s
channels) of the QSpan II. Please see the following chapters for a detailed explanation
of each component:
Chapter 3: “The QBus Slave Channel” on page 33
Chapter 4: “The PCI Target Channel” on page 55
Chapter 5: “The IDMA Channel” on page 83
Chapter 6: “The DMA Channel” on page 93
Chapter 7: “The Register Channel” on page 103
Chapter 8: “The Interrupt Channel” on page 113
Chapter 9: “The EEPROM Channel” on page 121
Chapter 10: “I2O Messaging Unit” on page 131
Chapter 11: “PCI Bus Arbiter” on page 139
Chapter 12: “CompactPCI Hot Swap Friendly Support” on page 143
Chapter 13: “PCI Power Management Event Support” on page 151
Chapter 14: “Reset Options” on page 153
Chapter 15: “Hardware Implementation Issues” on page 157
2.1 Overview
QSpan II has two interfaces: a PCI Bus Interface and a QBus Interface (see Figure 2).
The PCI Interface connects the QSpan II to the PCI bus. The QBus Interface connects
the QSpan II to the processor bus. Both interfaces support master and slave
transactions. The QBus Interface can be directly connected to an MC68360 (QUICC)
bus, an MPC860 (PowerQUICC) bus, or an M68040 bus. The QBus Interface can also
be connected to other buses with glue logic.
Each interface has two functional modules: a Master Module and a Slave/Target
Module. These modules are connected to QSpan II’s functional channels.
Chapter 2: Functional Overview
QSpan II User Manual30 May 16, 20 13
Figure 2: QSpan II Functional Diagra m
2.2 The QBus Slave Channel
The QBus Slave Channel transfers data between the QBus and the PCI bus (see
Figure 2). It supports posted writes, prefetched reads, and delayed single reads and
writes. Write transactions from the QBus to the PCI bus can be po sted or delayed.
Posted writes are queued in the Qx-FIFO with immediate data acknowledgment on the
QBus. QSpan II then completes the write on the PCI bus. For delayed reads, the data is
prefetched on the PCI bus and stored in the Qr -FIFO. Subsequent reads retrieve the data
from the Qr-FIFO. Delayed transactions both reads and writes require data
acknowledgme nt on the PCI bus before data ackno wledgment is provided on the QBus.
PCI Memory and I/O spaces are accessible through two Slave images associated with
the QBus Slave Channel. Configuration space is accessible through the CON_DATA
register (see Table 117 on page 258). The QBus Slave images are selected using a pair
of chip-select signals on the QSpan II (for information, see Chapter 3: “The QBus Slave
Channel” on page 33).
PCI
Target
Module
PCI Bus
Arbiter
PCI
Master
Module
QBus
Master
Module
QBus
Slave
Module
PCI
Interface QBus
Interface
PCI
Bus
Interrupt Channel
Register Channel
QBus
(Processor Bus)
I
2
O Messaging
CompactPCI
Hot Swap
QBus Slave Channel
Q-FIFOs
PCI Target Channel
P-FIFOs
IDMA/DMA Channel
I-FIFO (IDMA)
I-FIFO (DMA)
8091862.BK001.01
Chapter 2: Functional Overvi ew
QSpan II User Manual 31
May 16, 2013
2.3 The PCI Target Channel
The PCI Target Channel transfers data between the PCI bus and the QBus (see
Figure 2). It supports posted writes — to ensure zero-wait state bursting — prefetched
reads, and delayed single reads and writ es. The 2 56-byte Px-FIFO supp orts the queuing
of long PCI burst writes.
Delayed reads and writes must complete on the QBus before data acknowledgment
occurs on the PCI bus. Reads are executed as delayed transactions, but the QSpan II can
be configured to prefetch read data. Prefetched reads are queued in a 256-byte Pr-FIFO.
QSpan II provides two programmable Target images on the PCI bus. These images can
be mapped anywhere in Memory or I/O space (for information, see Chapter 4: “The PCI
Target Channel” on page 55).
2.4 The IDMA Channel
QSpan II can operate as an IDMA peripheral for data transfer between the QBus and the
PCI bus (see Figure 2). For transfers going to or from PCI, software can perform bulk
data movement using the QSpan II’s IDMA Channel. The IDMA Channel supports
single- and dual-address cycles, and fast-termination. A separate set of IDMA
handshake signals are provided on the QBus. The IDMA Channel can be used by
external QBus masters to read data from or write data to a PCI target in one direction at
a time. The IDMA Channel contains a 256-byte I-FIFO and a set of IDMA registers (for
information, see Chapter 5: “The IDMA Channel” on page 83).
2.5 The DMA Channel
QSpan II has a DMA Channel for high performance data transfer between the QBus and
the PCI bus (see Figure 2). The DMA controller uses the existing IDMA registers as
well as a few additional registers and shares the 256-byte I-FIFO with the IDMA
Channel. Because of the shared FIFO, the QSpan II cannot use its IDMA and DMA
Channels at the same time.
The DMA Channel operates in two modes: Direct Mode and Linked List Mode. In
Direct Mode, the DMA registers are programmed directly by an external master. In
Linked List Mode, the DMA registers are loaded from PCI bus memory or QBus
memory by the QSpan II (for information, see Chapter 6: “The DMA Channel”
on page 93).
2.6 The Register Channel
QSpan II provides 4 Kbytes of Control and Status Registers (QCSRs) to program PCI
settings, as well as the QSpan II’s device specific parameters (see Figure 2). QCSR
space is accessible from the PCI bus and the QBus.
An internal arbitration mechanism grants access to the QCSRs. The access mechanisms
for the QCSRs, including the arbitration pro t ocol, differ depending on whether the
registers are accessed from the PCI bus or the QBus.
Chapter 2: Functional Overview
QSpan II User Manual32 May 16, 20 13
PCI Configuration cycles can be generated from the QBus by accessing QSpan II
registers. The cycles proceed as delayed transfers (for information, see Chapter 7: “The
Register Channel” on page 103) .
2.7 The Interrupt Channel
QSpan II can generate interrupts based on hardware or software events (see Figure 2).
Two bidirectional interrupt pins are provided : one on the PCI Interface; the other on the
QBus Interface. Interrupt registers track the status of errors. They also allow users to
enable, clear , and map errors. Interrupts can be generated using one of the four available
software interrupt sources (for information, see Chapter 8: “The Interrupt Channel”
on page 113).
QSpan II also contains four mailbox registers which can be used for message passing
(for information, see “Mailbox Registers” on page 112). These mailbox registers can
generate an interrupt when data is written to them.
2.8 The EEPROM Channel
Some of QSpan II’s registers can be programmed by data in an EEPROM at system
reset. This allows board designers to set identifiers for their cards on the PCI bus at
reset. The identifiers enable the PCI Bus Expansion ROM Control Register
(PBROM_CTL) and set various address and image parameters. If the QSpan II is
configured with an EEPROM, the QSpan II can boot-up as a Plug and Play compatible
device; local processor initialization is also possible.
QSpan II supports reads from and writes to the EEPROM. The EEPROM device is not
included with the QSpan II (for more information, see Chapter 9: “The EEPROM
Channel” on page 121).
QSpan II User Manual 33
May 16, 2013
Chapter 3: The QBus Slave Channel
This chapter describes the QSpan II’s QBus Slave Channel. The following topics are
discussed:
“QBus Slave Channel Architecture” on page 34
“Channel Description” on page 36
“Address Phase” on page 37
“Data Phase” on page 44
“Termination Phase” on page 51
“PCI Master Retry Counter” on page 54
3.1 Overview
The QBus direct-connects to an MC68360 (QUICC) bus, an MPC860 (PowerQUICC)
bus, or an M68040 bus (see Figure 3). The QBus can also be direct-connected to a
combination of buses, such as an MC68360 bus and an MPC860 bus. A QBus master
uses the QBus Slave Channel or IDMA/DMA Channel to access a PCI target.
Chapter 3: The QBus Slave Channel
QSpan II User Manual34 May 16, 20 13
Figure 3: QBus Slave Channel — Functional Diagra m
3.2 QBus Slave Channel Ar chitecture
Figure 3 shows the QBus Slave Channel in relation to the QBus and the PCI bus. The
QBus is shown with an MPC 86 0 processor; the PCI bus is shown with a single PCI
device. The arrows represent data flow. The QBus Slave Channel has the following
components:
QBus Slave Module
Qx-FIFO
Qr-FIFO
•PCI Master Module
The QBus Slave Module and PCI Master Module are shared betwee n the QBus Slav e
Channel and the IDMA/DMA Channel. These components are discussed in the
following sections.
PCI
Target PCI
Master
Module
QBus
Slave
Module
QBus Slave Channel
PCI
Interface QBus
Interface
PCI
Bus QBus
Qx-FIFO
Qr-FIFO
QBus
Master
(MPC860)
Posted Writes
256 Bytes
Prefetched Reads
32 Bytes
Chapter 3: The QBus Slave Channel
QSpan II User Manual 35
May 16, 2013
3.2.1 QBus Slave Module
The QBus Slave Module is a non-multiplexed 32-bit address, 32-bit data interface. The
QBus Slave Module accepts MC68360 cycles, and either MPC860 or M68040 cycles.
The QBus Slave Module’s mode is set by the SIZ[1] signal at reset. This reset option is
summarized in Table 2 (for more information, see Chapter 14: “Reset Options”
on page 153). The MSTSLV[1:0] field in the Miscellaneous and Control Status register
(MISC_CTL) indicates the slave (and master) mode of the QBus (see Table 127 on
page 274). The connections required for interfacing the QSpan II to an MC68360,
MPC860, and/or M68040 are described in Appendix C: “Typical Applications”
on page 359.
3.2.1.1 QBus Data Parity Generation and Detection
The QBus Slave Module (QSM) supports the generation and detection of QBus data
parity. The use of QBus data parity is optional. Data parity is valid on the same clock
cycle as the QBus data. QSpan II supports Odd and Even parity, and is controlled by
QBUS_PAR in the MISC_CTL2 register (see Table 130 on page 278). Even parity is
the default setting, which is the same as the PCI bus. The detection of a QBus data
parity error does not affect the operatio n of the QSpan II. The PCI bus parity gene ration
and detection is independent of the QBus data parity generation and detection .
Four pins are used for the QBus Data Parity signals: DP[3:0]. When parity is set to
Even, the number of 1s on the QBus Data lines (D[7:0]) and DP[0] equal an even
number. Similarly, for Odd parity, the number of 1s on D[7:0] and DP[0] equal an odd
number. The following list shows which data parity signals DP[3:0] are used for which
data lines:
DP[0] contains the parity for data lines D[7:0]
DP[1] contains the parity for data lines D[15:8]
DP[2] contains the parity for data lines D[23:16]
DP[3] contains the parity for data lines D[31:24]
The QBus Slave Module generates the data parity when it completes a slave read cycle.
If it detects a parity error during a slave write cycle, it sets the QBus Data Parity Error
Status bit (QDPE_S) in the Interrupt Status (INT_STAT) register (see Table 119 on
page 260). QSpan II can generate an external interrupt (INT# or QINT_) depending on
the setting of QBus Data Parity Error Interrupt Enable (QDPE_EN) bit and QBus Data
Parity Error Interrupt Direction (QDPE_DIR) bit in INT_EN and INT_DIR registers,
respectively. Writing a 1 to the QDPE_S bit negates the interrupt and clears the status
bit.
Table 2: Reset Options for QBus Slave Modes
Reset sampling of SIZ[1] Slave Mode
0 MC68360 and M68040
1 MC68360 and MPC860
Chapter 3: The QBus Slave Channel
QSpan II User Manual36 May 16, 20 13
When the QBus Slave Module detects a parity error it sets the QDPE_S bit but
continues the transfer as if there were no parity error. For example, if a write is directed
to the QSpan II with a data parity error, the QBus Slave Module terminates the cycle
normally and passes it onto the QSpan II’s PCI interface. QSpan II’s PCI master
generates the write cycle with the correct parity for the data on the PCI bus.
QSpan II only checks data parity on valid bytes of data. If a single byte transfer is
completed on the QBus, only the valid byte on the data bus is checked (for example,
D[31:24]).
3.2.2 Qx-FIFO and Qr-FIFO
The Qx-FIFO is a 256-byte buffer for posted writes from the QBus to the PCI bus. The
Qx-FIFO supports sixty-four 32-bit entries. The Qx-FIFO accepts data from an external
QBus master while transferring data to a PCI target (for information, see “Writes” on
page 46).
The Qr-FIFO is a 32-byte buffer whic h stores data read from PCI Targets.
3.2.3 PCI Master Module
The PCI Master Module is a 32 bit/33MHz PCI 2.2 Specification compliant master
interface. PCI signals supported by the QSpan II are outlined in “PCI Bus Signals” on
page 172.
QSpan II masters the PCI bus through its PCI Master Module. The PCI Master Module
is available to the QBus Slave Channel (access from a remote QBus master) and the
IDMA/DMA Channel.
3.3 Channel Description
The operation of the QBus Slave Channel is described in the following sections by
tracing the path of a transaction from the QBus to the PCI bus. This is completed by
dividing a transaction into three phases:
Address Phase: This section describes transa ction decoding and how address
information from the QBus is passed to a corresponding address space on the PCI
bus.
Data Phase: This section describes endian mapping and byte-lane translation
through the QBus Slave Channel. This section also describes the methods that data
is buf fered in the QBus Slave Chann el depending on the pr ogramming of the QBus
Slave images.
Termination Phase: This section discusses how terminations from a PCI target are
communicated to the master on the QBus. It also describes how the QSpan II PCI
Master Module handles terminations (for example, retries or Target-Aborts). We
also describe the terminations the QSpan II issues as a QBus slave device.
The Qx-FIFO is on the data path for single delayed writes. A delayed
write must be completed before the following write can be posted.
Chapter 3: The QBus Slave Channel
QSpan II User Manual 37
May 16, 2013
3.4 Address Phase
3.4.1 Transaction Decoding and QBus Slave Images
QSpan II accepts a transaction through its QBus Slave Module when one of its chip
selects is asserted along with the Address Strobe (AS_) or Transaction Start signal
(TS_). The chip selects, CSREG_ and CSPCI_, do not need to be detected asserted on
the same clock edge as TS_ for QBus Slave Channel accesses. This allows for wait
states to be inserted to perform address decoding. However , the IDMA Channel requires
that CSPCI_ be detected asserted on the same clock edge as TS_ for dual-address
IDMA transfers.
If CSREG_ is asserted, then the transaction is decoded as a QSpan II register access (if
the address 0x504 is a PCI Configuration cycle, see Chapter 7: “The Register Channel”
on page 103). In order to access the PCI bus, the QBus master (or address decoder
circuitry) asserts the PCI chip-select pin (CSPCI_) and the QBus Slave Module claims
the cycle for the QBus Slave Channel. One of the two QBus Slave Images is selected
during this transaction. The QBus Slave Image is qualified by the Image Select Signal
(IMSEL).
The type of PCI cycle generated by the QSpan II depends on the following:
which QBus Slave Image is selected
the type of transaction initiated by the external QBus master
The level of IMSEL determines which of the two QBus Slave Images is used. If IMSEL
is 0, QBus Slave Image 0 is selected (see Table 133 on page 283 and Table 138 on
page 285); if IMSEL is 1, QBus Slave Image 1 is selected (see Table 140 on page 287
and Table 145 on page 289). The levels of BURST_ and R/W_ determine whether the
QSpan II will generate a single PCI cycle or a burst, a PCI read or a write, respectively.
There is some interaction between images and hardware signals, as described in
Tables 133 to 145.
A Slave Image is a set of parameters which are encoded in QSpan II registe rs. A Slave
Image controls transfers between the QBus and the PCI bus. Similar Target Images are
provided in the PCI Target Channel. Two QBus Slave images of equal capability are
provided so that designers can quickly access — on the basis of hardware rather than
software — PCI addresses from the QBus, or access addresses in different ways. The
two Slave Images are completely independent from one another.
For example, the designer can set-up QBus Slave Image 0 to access a hard-disk using
128 Mbytes of memory in PCI memory space. The designer can simultaneously have
QBus Slave Image 1 available to access a different device, with its own memory size.
The designer can access the first device with posted writes — Posted Write Enable
(PWEN) bit set to 1 — and the other with delayed writes — PWEN set to 0. For a third
type of access, it would be necessary to share one of the Slave Images.
Single address IDMA transfers do not require CSPCI_ to be asserted.
Chapter 3: The QBus Slave Channel
QSpan II User Manual38 May 16, 20 13
The following tables summarize the QBus Slave Image control and address fields.
The QBus Slave Channel allows a QBus master to access a range of addresses in PCI
Memory or I/O space. The PCI address space bit (PAS) of the selected image
determines whether the current transfer is directed towards PCI Memory or I/O space.
The range of addresses that can be accessed through a Slave Image is controlled by the
block size (BS) field. Up to 2 Gbytes of PCI Memory or I/O space can be accessed from
the QBus in one Slave Image if address translation is required. The use of the Block
Size, PCI Address Space, Translation Address and Enable Address T ranslation fields is
discussed in “Address T ranslation” on page 40, and “Address Phase on the PCI Bus” on
page 43.
The QBus Slave Image Control registers specify how writes are processed (see
Table 133 on page 283 and Table 140 on page 287). If the PWEN bit is 1, the QSpan II
will perform posted writes when the specific QBus Slave Image is accessed with a
single write. Otherwise writes are handled as single delayed transactions. If the PREN
bit is 1, the QSpan II will perform a burst read on the PCI bus when the MPC860 or
MC68360 performs a single 32-bit read on the QBus. Otherwise, the QSpan II will
handle this as a single delayed read transaction.
QBus Slave Image 0 can also be programmed from an external EEPROM (for
information, see “Mapping of EEPROM Bits to QSpan II Registers” on page 124.
Table 3: Address Fields for QBus Slave Image
Field Abbreviation and
Register Page Description
Block Size BS (Table 138 on page 285 and Table 145
on page 289) Amount of PCI memory
accessible from QBus
PCI Address Space PAS (T able 133 on page 283 and Table 140
on page 287) Mapping to PCI memory
space or I/O space
Translation Address TA (Table 138 on page 285 and Table 145
on page 289) Address bits that are substituted to generate
the PCI bus address
Enable Address
Translation EN (Table 138 on page 285 and Table 145
on page 289) Enables address translation using TA field
Table 4: Control Fields for QBus Slave Image
Field Abbreviation and Register Page Description
Posted Write PWEN (Table 133 on page 283 and
Table 140 on page 287) Posted write enable bit
Prefetch Read PREN (Table 133 on page 283 and
Table 140 on page 287) Prefetch read enable bit
Chapter 3: The QBus Slave Channel
QSpan II User Manual 39
May 16, 2013
3.4.1.1 MPC860 Cycles
QSpan II behaves as an MPC860 slave in response to the assertion of the TS_ signal
when it is powered-up as an MPC860 slave (see “QBus Slave Module” on page 35).
When the QBus Slave Module receives TS_ it responds with DSACK1_/TA_,
BERR/TEA_, or HALT_/TRETRY_. QSpan II acknowledges the transaction if either
CSREG_ or CSPCI_ is sampled active in conjunction with TS_. QSpan II samples the
address bus and control signals on the same rising edge of QCLK in which it samples
either CSPCI_ or CSREG_ asserted.
If BURST_/TIP_ is asserted at the beginning of the bus cycle, along with the address,
the QSpan II accepts the incoming cycle as a burst. During bursts, the QSpan II
monitors BDIP_, which when negated, indicates the current data phase is second last.
3.4.1.2 MC68360 Cycles
QSpan II behaves as a MC68360 slave in response to the assertion of the Address
Strobe (AS_) signal. When it receives AS_ it asserts a subset of DSACK1_/TA_,
DSACK0_, BERR_/TEA_ and HALT_/TRETRY_. QSpan II acknowledges the
transaction if either CSREG_ or CSPCI_ is sampled active in conjunction with AS_.
QSpan II does not require that the input signals qualified by AS_ be valid when AS_ is
asserted — it requires only that they meet the set-up time before the same falling clock
edge when AS_ is first sampled asserted.
When the QSpan II operates as a MC68360 slave, it functions as a 32-bit peripheral in
synchronous mode. As a master, the QSpan II also operates synchronously and
therefore the Bus Synchronous Timing mode (BSTM) bit in the MC68360 must be set
to 1 (for more information, see the Motorola MC68360 Users Manual). External QBus
masters must comply with the MC68360 timing specification.
3.4.1.3 M68040 Cycles
QSpan II behaves as an M68040 slave in response to the assertion of the TS_ signal
when it is powered-up as an M68040 slave (see “QBus Master and Slave Modes” on
page 156). When the QBus Slave Module receives TS_ it responds with
DSACK1_/TA_ or BERR_/TEA_. QSpan II recognizes a transaction as intended for it,
and acknowledges it accordingly, only if one of CSREG_ or CSPCI_ is sampled active
in conjunction with TS_. QSpan II samples the address bus and other TS_ qualified
signals on the same rising edge of QCLK in which it samples TS_ asserted. The QBus
Slave Module accepts bursting of incoming data.
When the QSpan II operates as an MPC860 slave for non-IDMA
transfers, it functions as a 32-bit peripheral and must be addressed as a
32-bit peripheral. External QBus masters must comply with the MPC860
timing specification.
When the QSpan II operates as an M68040 slave, it functions as a 32-bit
peripheral in synchronous mode and must be addressed as a 32-bit
peripheral. External QBus masters must comply with the M68040 timing
specification.
Chapter 3: The QBus Slave Channel
QSpan II User Manual40 May 16, 20 13
3.4.2 PCI Bus Request
The PCI Master Module requests the PCI bus when one of the following occurs:
write data is received in the Qx-FIFO
after the last data phase of a burst write is received in the Qx-FIFO
if there is a read request
If the QSpan II is powered up to use an external PCI bus arbiter when it requires control
of the PCI bus, it asserts REQ# and gains bus mastership when the PCI ar biter asserts
grant. If the QSpan II is powered up to use the internal PCI bus arbiter , the request-grant
signals are internal. If the arbiter removes grant after the QSpan II has begun its PCI
transaction, the QSpan II completes the current cycle and releases the PCI bus. This
means that the QSpan II PCI Master Module will have to re-arbitrate for the PCI bus
after every cycle if its grant is remove d. QSpan II performance as PCI master can be
enhanced through bus parking, as defined in the PCI Local Bus Specification 2.2 (for
more information about bus parking, see “Bus Parking” on page 142).
3.4.3 Address Translation
The QBus Slave Channel contains an Address Generator (see Figure 4) which is used if
address translation is enabled (EN bit in Table 138 or Table 1 45). The Address
Generator produces the PCI address using three inputs: the address of the QBus signal
(A[31:0]), the block size of the QBus Slav e Image (BS field of the QBSIx_AT register),
and the translation address of the QBus Slave Image (TA field of the QBSIx_AT
register). The translation address is a 16-bit number whose upper bits specify the
location of the Target Image on the PCI bus. The correlation between BS and the
number of TA bits to use in generating the PCI address is shown in Table 5 on page 42.
For example, with a 64 Kbyte block size, the Address Generator copies the entire
translation address into the PCI address, but only copies the lower 16 bits from the
QBus address signals. With a 2 Gbyte block size, the Address Generator copies all but
bit 31 from the QBus address signal. For example, the Address Generator translates
A[31] only while copying A[30:0]), and uses the top translation address bit as bit 31 of
the PCI address.
QSpan II cannot be master and target on the PCI bus at the same time.
Chapter 3: The QBus Slave Channel
QSpan II User Manual 41
May 16, 2013
Figure 4: Address Generator for QBus Slave Channel Transfers
This manual adopts the convention that the most significant bit (address
or data) is always the largest number. MPC860 designers must ensure that
they connect their pins accordingly. For example, pin A[31] on the QSpan
II connects to pin A[31] on the MC68360 bus, but connects to pin A[0] on
the MPC860 bus. This applies to all MPC860 buses (D[31:0], AT[3:0],
TSIZ[1:0]) not only the address bus.
Translation Address QBus Address Block Size
Address Generator
PCI Address
Chapter 3: The QBus Slave Channel
QSpan II User Manual42 May 16, 20 13
Table 5: Translation of QBus Address to PCI Address
BS in QBSI0_CTL or
QBSI1_CTL Block Size Address Lines
Translated Translation Address Bits
Copied
0000 64 Kbytes A31–A16 TA31–TA16
0001 128 Kbytes A31–A17 TA31–TA17
0010 256 Kbytes A31–A18 TA31–TA18
0011 512 Kbytes A31–A19 TA31–TA19
0100 1 Mbyte A31–A20 TA31–TA20
0101 2 Mbytes A31–A21 TA31–TA21
0110 4 Mbytes A31–A22 TA31–TA22
0111 8 Mbytes A31–A23 TA31–TA23
1000 16 Mbytes A31–A24 TA31–TA24
1001 32 Mbytes A31–A25 TA31–TA25
1010 64 Mbytes A31–A26 TA31–TA26
1011 128 Mbytes A31–A27 TA31–TA27
1100 256 Mbytes A31–A28 TA31–TA28
1101 512 Mbytes A31–A29 TA31–TA29
1110 1 Gbyte A31–A30 TA31–TA30
1111 2 Gbytes A31 TA31
Chapter 3: The QBus Slave Channel
QSpan II User Manual 43
May 16, 2013
3.4.4 Address Phase on the PCI Bus
The address supplied on the AD[31:0] lines on the PCI bus is the result of the address
translation described in the previous section. The PCI command encoding on the
C/BE#[3:0] lines is determined by the type of transaction on the QBus, and the
programming of the PCI Bus Address Space (PAS) and Prefetch Read Enable (PREN)
bits in the QBus Slave Image Control Registers (see Table 133 on page 283 or
Table 140 on page 287). The following table lists the C/BE encoding supported by the
QSpan II.
Table 6: Command Type Encoding for Transfer Type
C/BE# [3:0] Command Type QSpan II Capability
0000 Interrupt Acknowledge See “Interrupt Acknowledge Cycle” on
page 119
0001 Special Cycle N/A
0010 I/O Read Target/Master
0011 I/O Write Target/Master
0100 Reserved N/A
0101 Reserved N/A
0110 Memory Read Target/Master
0111 Memory Write Target/Master
1000 Reserved N/A
1001 Reserved N/A
1010 Configuration Read Target/Master
1011 Configuration Write Target/Master
1100 Memory Read Multiple Targeta/Master
a. These commands are aliased to a memory read.
1101 Dual Address Cycle N/A
1110 Memory Read Line Ta rgeta/Master
1111 Memory Write and Invalidate Targetb/Master
b. This command is aliased to a memory write.
Chapter 3: The QBus Slave Channel
QSpan II User Manual44 May 16, 20 13
PCI Targets are expected to assert DEVSEL# if they have decoded the access. If a tar get
does not respond with DEVSEL# within 6 clocks, a Master-Abort is generated by the
QSpan II. The following shows the mappin g from QBus transaction type to PCI
transaction type as a function of PAS programming.
3.5 Data Phase
This section describes how endian mapping is executed in the QBus Slave Channel. It
also discusses the data path for different transaction types.
3.5.1 Endian Mapping
The PCI bus and Motorola processors differ in the way they order and address bytes.
These differences are explained in Appendix E: “Endian Mapping” on page 389. This
section describes how the QSpan II translates cycles from the QBus to the PCI bus.
The PCI bus is always a Little-Endian environment. The QBus can be configured as
Little-Endian or Big-Endian, depending on the value of the QBus Byte Ordering
Control bit (QB_BOC) in the MISC_CTL register (see Table 127 on page 274). The
default mode for the QBus is Big-Endian. QSpan II translates byte-lane ordering when
the QBus is Big-Endian, while preserving the addressing of bytes. When the QBus is
Little-Endian, the QSpan II preserves byte-lane ordering, while translating the
addressing of bytes. Note that the QB_BOC bit affects transactions in all channels.
Table 7: Translation from QB us Transaction to PCI Transaction Type
QBus transaction received PAS bit programming PCI transaction type
Single or Burst Read Memory Memory Read
Single Read I/O I/O Read
Burst Read I/O Nonea
a. In this case an error is signaled on the QBus.
Single or Burst Write Memory Memory Write
Single Wr ite I/O I/O Write
Burst Write I/O Nonea
Chapter 3: The QBus Slave Channel
QSpan II User Manual 45
May 16, 2013
The following tables describe cycle mapping for Little-Endian and Big-Endian of all
sizes (8, 16, 24, or 32 bits).
Table 8: Little-Endian QBus Slave Channel Cycle Mapping
QBus PCI Bus
SIZ[1:0] A[1:0] D[31:0] BE[3:0]# D[31:0]
01 00 B3 xx xx xx 0111 B3 xx xx xx
01 01 xx B2 xx xx 1011 xx B2 xx xx
01 10 xx xx B1 xx 1101 xx xx B1 xx
01 11 xx xx xx B0 1110 xx xx xx B0
10 00 B3 B2 xx xx 0011 B3 B2 xx xx
10 01 xx B2 B1 xx 1001 xx B2 B1 xx
10 10 xx xx B1 B0 1100 xx xx B1 B0
10 11 xx xx xx B0 1110 xx xx xx B0
11 00 B3 B2 B1 xx 0001 B3 B2 B1 xx
11 01 xx B2 B1 B0 1000 xx B2 B1 B0
11 10 xx xx B1 B0 1100 xx xx B1 B0
11 11 xx xx xx B0 1110 xx xx xx B0
00 00 B3 B2 B1 B0 0000 B3 B2 B1 B0
00 01 xx B2 B1 B0 1000 xx B2 B1 B0
00 10 xx xx B1 B0 1100 xx xx B1 B0
00 11 xx xx xx B0 1110 xx xx xx B0
Chapter 3: The QBus Slave Channel
QSpan II User Manual46 May 16, 20 13
3.5.2 Data Path
3.5.2.1 Writes
If the PWEN bit is set in the QBSIx_CTL register, single write transactions from the
QBus will be posted (see Table 133 on page 283 and Table 140 on page 287). The level
of IMSEL determines which QBSIx_CTL register is used (see “Transaction Decoding
and QBus Slave Images” on page 37). If the PWEN bit is cleared — this is the default
setting — single write transactions are treated as delayed transactions. Burst write
transfers are always treated as posted writes.
Both posted and delayed writes travel through the Qx-FIFO. With posted writes, data
acknowledgme nt is provided on the QBus as soo n as the write data is queued in the
Qx-FIFO. Multiple posted writes can be queued up to the 256-byte capacity of the
Qx-FIFO. With delayed writes, data acknow ledgment is provided on the QBus after
completion on the PCI bus. This means only one delayed write at a time. Additional
writes are retried while a delayed write is in progress.
Table 9: Big-Endian QBus Slave Chann el Cycle Mapping
QBus PCI Bus
SIZ[1:0] A[1:0] D[31:0] BE[3:0]# D[31:0]
01 00 B0 xx xx xx 1110 xx xx xx B0
01 01 xx B1 xx xx 1101 xx xx B1 xx
01 10 xx xx B2 xx 1011 xx B2 xx xx
01 11 xx xx xx B3 0111 B3 xx xx xx
10 00 B0 B1 xx xx 1100 xx xx B1 B0
10 01 xx B1 B2 xx 1001 xx B2 B1 xx
10 10 xx xx B2 B3 0011 B3 B2 xx xx
10 11 xx xx xx B3 0111 B3 xx xx xx
11 00 B0 B1 B2 xx 1000 xx B2 B1 B0
11 01 xx B1 B2 B3 0001 B3 B2 B1 xx
11 10 xx xx B2 B3 0011 B3 B2 xx xx
11 11 xx xx xx B3 0111 B3 xx xx xx
00 00 B0 B1 B2 B3 0000 B3 B2 B1 B0
00 01 xx B1 B2 B3 0001 B3 B2 B1 xx
00 10 xx xx B2 B3 0011 B3 B2 xx xx
00 11 xx xx xx B3 0111 B3 xx xx xx
Chapter 3: The QBus Slave Channel
QSpan II User Manual 47
May 16, 2013
Posted write transfers are stored in the Qx-FIFO . Address and data are stored as
separate entries in the Qx-FIFO. For example, one single cycle data beat transaction is
stored as two Qx-FIFO entries: one entry for the address of the transaction, and one for
the data. The address entry contains the transla t ed PCI address space and command
information mapping relevant to the QBus Slave Image which is accesse d (see
“Address Phase” on page 37). The data entry contains the data and the byte enables.
Thus, any reprogramming of QBus Slave Image attributes will only be reflected in
Qx-FIFO entries queued after the reprogramming. Transactions queued before the
reprogramming are delivered to the PCI bus with the QBus Slave Image attributes that
were in use before the reprogramming. QSpan II never packs data in the Qx-FIFO. For
example, two 16-bit data beats are not packed as a single 32-bit data entry but as four
separate entries in the Qx-FIFO (address, data , address, data).
If a QBus master attempts to post a write transaction when the Qx-FIFO does not have
enough space, the QBus Slave Channel retries the master. The exact manner in which
the master is retried depends on whether the master is an MC68360, MPC860 or
M68040 device (see “T ermination Phase” on page 51. Since single transfers require two
entries in the Qx-FIFO, two entries must be available before the QBus Slave Module
accepts a single write transaction. However , the 256-byte depth of the Qx-FIF O ensures
a very low probability that the Qx-FIFO is too full to accept write transactions.
The PCI Master Module requests the PCI bus when there is a complete transaction in
the Qx-FIFO. During write transactions, the PCI Master Module uses transactions
queued in the Qx-FIFO to generate transactions on the PCI bus. No address phase
deletion is performed; thus, the length of a transaction on the PCI bus corresponds to the
length of the queued QBus transaction.
Only MPC860 and M68040 Masters are capable of initiating burst transactions.
Incoming burst write transactions comprise five entries in the Qx-FIFO: one entry for
address and command information, and four data entries. The QBus Slave Module
accepts bursts if the Qx-FIFO has enough room for the entire burst. Burst transfers are
never retried while they are in progress. The MPC86 0 and M68040 perform bursts of 16
bytes. Bursts accepted from the QBus are translated to the PCI bus as one or more burst
transactions. QSpan II always bursts using linear increment addressing.
Burst transactions are always posted, regardless of the programming of the PWEN bit in
the selected QBSIx_CTL register. QSpan II accepts bursts targeted to Memory space,
but not to I/O or Configuration space. If the PCI address space (PAS) bit of the selected
image is set to I/O space and a burst is initiated by a QBus master, then the QSpan II
signals a bus error. Similarly , if a burst is attempted to the QSpan II registers, a bus error
is signaled by the QSpan II (see “Termination Phas e” on page 51).
To improve performance of posted write transfers, set the QSC_PW bit in
the MISC_CTL2 register (see Table 130 on page 278). This configuration
reduces the number of idle PCI clocks between posted write transfers
initiated by the QSpan II’s PCI master.
Chapter 3: The QBus Slave Channel
QSpan II User Manual48 May 16, 20 13
3.5.2.2 Read Transactions — Burst and Single Cycle
During a read transaction, address, data, size and transaction code signals are latched by
the QBus Slave Module. After latching the information, the QSpan II retries all
incoming QBus cycles, but does not latch them until the read completes on the QBus.
QSpan II becomes PCI bus master and performs a read transaction on the PCI bus . Th e
read data is queued in the Qr-FIFO. If the PCI transaction completes normally, then the
QBus master is provided with the data from the Qr-FIFO and the transaction terminates
normally on the QBus (see “Termination Phase” on page 51).
If the QBus master attempts a burst read to the QBus Slave Module, and the Slave
Image is programmed for PCI Memory Space, then the QSpan II initiates a read cycle.
If the read is attempted to a Slave Image programmed for PCI I/O Space, or to QSpan II
registers, then the QBus Slave Module terminates the access with a bus error.
3.5.2.3 Prefetched Reads
QSpan II supports prefetched reads in the QBus Slave Channel for MPC860 and
MC68360 cycles; M68040 cycles are not supported. To enable prefetching on an image
basis, set the PREN bit in QBSI0_CTL or QBSI1_CTL. When this bit is set, and the
QSpan II decodes a single 32-bit aligned, 4-byte read on the QBus from an external
master, it initiates a prefetch of 32 bytes on the PCI bus using linear-address
incrementing. Once all 32 bytes are available in the Qr-FIFO, the external QBus master
receives the first four bytes of read data. If a subsequent read is performed at the next
address, which is the current address +0x4, the QSpan II returns the data from Qr-FIFO
instead of completing another read on PCI.
Transaction ordering is strictly enforced for the first data read. Before the read is
completed on the PCI bus, any posted writes in the Qx-FIFO are emptied on the PCI
bus. Before the first read data is returned on the QBus, any posted writes in the Px-FIFO
are emptied on the QBus. When reading subsequent prefetched data from the Qr-FIFO,
the QSpan II does not check whether the posted FIFOs (Qx-FIFO and Px-FIFO) are
empty.
The prefetched data, not including the first 4 bytes, is invalidated under the following
conditions:
QBus discard timer expires: 32768 QCLKs after the first read data is available
Delayed write cycle is latched in the QBus Slave Channel
Delayed read cycle to an address that is not the current address +0x4, or a non
4-byte access through the QBus Slave Channel
Burst MPC860 read cycle through the QBus Slave Channel
A burst read is four beats in length (16 bytes).
Chapter 3: The QBus Slave Channel
QSpan II User Manual 49
May 16, 2013
When the QSpan II detects a single read cycle that is not 32-bit aligned or is not a
4-byte access, it performs a single read on the PCI bus with the appropriate byte
enables.
If the QSpan II detects a prefetchable cycle when it is active during an MPC860 IDMA
transfer (DREQ_ asserted), it converts the prefetch cycle into a normal delayed read
cycle because the DACK_ can be delaye d with respect to TS_. QSpan II does not need
to convert prefetchable cycles of the MC68360 because DACK_ has the same timing as
AS_.
During a burst read on the PCI bus (which is a result of a prefetch) if one of the data
beats is terminated with an error, the 32 bytes are invalidated and the QSpan II
terminates the cycle on the QBus with a Bus Error.
3.5.2.4 Delayed Reads and PCI Transaction Ordering
In order to satisfy PCI Transaction Ordering requirements, the rules described in this
section are implemented in the QSpan II (see “Delayed Reads” in the PCI 2.2
Specification). These rules affect the relation between delayed reads and posted writes
in the QBus Slave Channel. The rules also affect the relation between delayed reads in
the QBus Slave Channel and posted writes in the PCI Target Channel.
The following list summarizes the sequence of QSpan II events:
1. The QBus Slave Module receives a read request.
2. The QBus Slave Channel empties the Qx-FIFO of any writes or completes any
current reads.
3. The QBus Slave Module latches the read request.
4. The QBus Slave Module retries subsequent non-register accesse s.
5. The PCI Master Module completes the read on the PCI bus.
6. The PCI Target Module retries all non-register accesses.
7. The Px-FIFO is emptied.
In the case of QBus Slave Channel burst reads:
8. The PCI Target Module allows posted writes to the Px-FIFO.
9. The QBus Slave Module allows the burst read to complete on the QBus.
10. The QBus Slave Module accepts new accesses.
In the case of QBus Slave Channel single reads:
8. The QBus Slave Module allows the read to complete on the QBus.
9. The QBus allows posted writes to the Qx-FIFO, even if the single read has not
completed.
10. The PCI Target Module allows posted writes to the Px-FIFO.
Chapter 3: The QBus Slave Channel
QSpan II User Manual50 May 16, 20 13
Tr ansaction Ordering Disable Option
The No Transaction Ordering (NOTO) bit in the MISC_CTL2 register disables
transaction ordering between the QBus Slave Channel and the PCI Target Channel (see
Table 130 on page 278). When this bit is set, a read in one channel is unaffected by
posted writes in the other channel.
This feature improves system performance, especially when using the DMA and where
strict transaction ordering is not required.
3.5.3 PCI Target Channel Reads
In PCI Target Channel reads, the PCI Target Module latches the read request even when
there is data in the Px-FIFO. The PCI Target Module only passes the information onto
the QBus Master Module when the Px-FIFO is empty (see “Reads and PCI Transaction
Ordering” on page 75).
3.5.4 Parity Monitoring by PCI Master Module
QSpan II monitors the Parity signal (PAR) when it accepts data as a PCI master during a
read, and drives PAR when it provides data as a PCI master during a write. QSpan II
also drives PAR during the address phase of a transaction when it is a PCI master. In
both address and data phases, the PAR signal provides even parity for C/BE#[3:0] and
AD[31:0].
The PERESP (Parity Error Response) bit in the PCI_CS (PCI Configuration Space
Control and Status register) determines whether or not the QSpan II responds to parity
errors as PCI master (see Table 70 on page 201). Data parity errors are reported through
the assertion of PERR# if the PERESP bit is set.
The Detected Parity Error (D_PE) bit in the PCI_CS register is set if the QSpan II
encounters one of the following situations:
a parity error during an address phase
a parity error during a write when QSpan II is the target
a parity error during a read when QSpan II is the master
The Master Data Parity Error Detect (MD_PED) bit in the PCI_CS register is set if
parity checking is enabled through the PERESP bit, and the QSpan II detects a parity
error while it is PCI master (for example, it asserts PERR# during a read transaction or
receives PERR# during a write). If the QSpan II sets the MD_PED bit while the
MDPED_EN (Data Parity Detected Interrupt Enable) bit in the INT_CTL register is set
(see Table 120 on page 263), then the QSpan II asserts an interrupt on the QBus or PCI
bus interface (see Chapter 8: “The Interrupt Channel” on page 113).
QSpan II continues the transaction regardless of any parity errors reported during the
transaction.
Chapter 3: The QBus Slave Channel
QSpan II User Manual 51
May 16, 2013
3.6 Termination Phase
Except during posted writes, the termination generated by the QBus Slave Module is
determined by the termination on the PCI bus (see “Posted Write Termination” on
page 53). For read transactions and delayed write transactions, the QBus master is
retried until the PCI transaction is complete. Once the PCI transaction is complete, the
QBus master receives a translated version of the PCI termination. The following table
shows how PCI terminations are translated to the QBus Slave Module during delayed
transactions, such as delayed single reads, delayed single writes and reads.
The QBus Slave Module retries accesses under the following conditions:
A QBus master attempts to post another write to the QBus Slave Channel and the
Qx-FIFO does not have enough room for the write.
A QBus master attempts a burst write transfer and there is not enough room in the
Qx-FIFO for the complete burst. The QBus Slave Module never retries an ongoing
burst transaction.
A prefetched read is in progress in the QBus Slave Channel.
A delayed transfer — read or write — is in progress in the QBus Slave Channel.
The QBus Slave Module generates a bus error under the following conditions:
A QBus master attempts to burst to a Slave Image whose transfers have been set to
I/O space.
Table 10: Translation of Cycle Terminationa from PCI Bus to QBus
a. This table applies to delayed transfers.
PCI Bus Termination Received QBus Termination Issued
Master-Completion Normal
Master-Abort Bus Error if MA_BE_D bit is 0.
Normal if MA_BE_D bit is 1 (reads return all
1s, write data flushed).
Target-Retry N/Ab
b. These cycles are not translated. The QBus Slave Module retries the master during delayed
transactions until one of the other terminations is received.
Target-Disconnect
Target-Abort Bus Error if MA_BE_D bit is 1 and the
TA_BE_EN bit is 1.
Normal if MA_BE_D bit is 1 and the
TA_BE_EN bit is 0 (reads all 1s; write data
flushed).
Chapter 3: The QBus Slave Channel
QSpan II User Manual52 May 16, 20 13
A delayed transfer or a prefetched read results in a Target-Abort and the
MA_BE_D bit in the MISC_CTL register is 0, or the MA_BE_D bit is 1 and the
TA_BE_EN bit in the MISC_CTL2 register is 1.
A delayed transfer results in a Master-Abort and the MA_BE_D bit in the
MISC_CTL register is 0.
The mapping of the QBus terminations to the MC68360, MPC860, and M68040 buses
is shown in Tables 11 to 13.
Set the MA_BE_D (see Table 127 on page 274) and TA_BE_EN (see
Table 130 on page 278) bits if the QSpan II is used as a host bus bridge.
This is in compliance with the PCI Local Bus Specification 2.2.
Table 11: MC68360 Cycl e Terminations of QBus Slave Module
Termination Type DSACK0_,
DSACK1_/TA_ BERR_/TEA_ HALT_/TRETRY_
Normal Asserted Tri-stateda
a. External pull-ups bring tri-stated signals to the non-asserted state.
Tri-stated
Bus Error Asserted Asserted Tri-stated
Retry Asserted Asserted Asserted
Table 12: MPC860 Cycle Terminations of QBus Slave Module
Termination Type DSACK1_/TA_ BERR_/TEA_ HALT_/TRETRY_
Normal Asserted Tri-stateda
a. External pull-ups bring tri-stated signals to the non-asserted state.
Tri-stated
Bus Error Tri-stated Asserted Tri-stated
Retry Tri-stated Tri-stated Asserted
Table 13: M68040 Cycle Terminations of QBus Slave Module
Termination Type DSACK1_/TA_ BERR_/TEA_
Normal Asserted Tri-stateda
a. External pull-ups bring tri-stated signals to the non-asserted state.
Bus Error Negated Asserted
Retry Asserted Asserted
Chapter 3: The QBus Slave Channel
QSpan II User Manual 53
May 16, 2013
The following table summarizes the QSpan II’s response to abnormal terminations on
the PCI bus.
3.6.1 Posted Write Termination
QBus terminations of posted writes are not influenced by the PCI bus termination. If a
posted write is terminated by a Target-Abort or Master-Abort on the PCI bus, this
termination is not signaled on the QBu s to the QBus master. However , errors on the PCI
bus are accessible to external QBus Masters through error logging. Error logging is
enabled by the EN bit of the PCI Bus Error Log Control and Status Register
(PB_ERRCS) register. Errors can be enabled to cause interrupts (see Table 98 on
page 234).
Table 14: QBus Slave Channel Error Responses
Transfer-
type PCI Error Type MA_BE_D in
MISC_CTL TA_BE_EN in
MISC_CTL2 Flush FIFOa
a. This column per t ain s to Qr-FIFO for reads, and Qx-FIFO for writes.
QBus Termination
read Master-Abort 0 x Yes Bus error
1xYesNormal
(return all 1)
Target-Abort 0 x Yes Bus error
10YesNormal
(return all 1)
1YesBus error
posted
write Master-Abort 0 x No. Lose one entr y,
continue sinking
data.b
b. If a single posted write transfer results in a Master -Abort, then this complete transaction is lost and the QSpan will
continue sinking any subsequent posted write entries.
If a burst write results in a Master-Abort on the first data beat, then this data entry is lost. It is likely that the
second, third and fourth entries of the burst will also result in a Master-Abort and this data will be lost as well.
Normal
1x
No. Lose one entry,
continue sinking
data.b
Normal
Target-Abort 0 x No. Lose one entry,
continue sinking
data.b
Normal
1x
No. Lose one entry,
continue sinking
data.b
Normal
Chapter 3: The QBus Slave Channel
QSpan II User Manual54 May 16, 20 13
QSpan II can record the address, command, data, and byte enables of a posted write
transaction that results in a Master-Abort or Target-Abort. The EN bit of the
PB_ERRCS register enables error recording. If enabled, the occurrence of an error is
indicated by the ES bit of the PB_ERRCS register . T ransfers in the QBus Slave Channel
are suspended until the ES bit is cleared if the Unlock QBus Slave Channel
(UNL_QSC) bit in the PB_ERRCS register is set to 0 (see Table 98 on page 234). IDT
recommends that the UNL_QSC bit always be set to 1 if error logging is enabled. If
enabled, the PB_ERRCS register latches the command information of the transaction
error (CMDERR field) as well as the byte enables of the transaction error (BE_ERR
field). The address of the transaction error is latched in the PCI Bus Address Error Log
(PB_AERR) register. The data of the transaction error is latched in the PCI Bus Data
Error Log Register (PB_DERR) register.
If error logging is enabled with UNL_QSC set to 1, and the QBus Slave Channel is
errored, the QSpan II’s PCI bus Master interface is not halted. However, the error logs
are frozen with the first failed transaction until the status bit is cleared.
If error logging is not enabled and the QBus Slave Channel incurs an error while
dequeuing data, the errored transfer is lost and the Qx-FIFO operation continues with
the next enqueued transfer.
An interrupt will be generated upon the logging of an error (ES bit in PB_ERRCS) only
if the PCI Bus Error Log Interrupt Enable (PEL_EN) bit in the INT_CTL register is set
(see Table 119 on page 260). If generated, the interrupt is directed to the QBus or the
PCI bus, depending on the PCI Error Log Interrupt Direction (PEL_DIR) bit in the
INT_DIR register (see Table 121 on page 266). Interrupts are described in Chapter 8:
“The Interrupt Channel” on page 113.
3.7 PCI Master Retry Counter
QSpan II PCI master limits the number of times a cycle is repeated on the PCI bus due
to an external PCI target terminating the cycle with a retry. QSpan II can be
programmed to accept the follo wing number of retires: 128, 256, 384 , or indefinitely,
depending on the setting of the MAX_RTRY in the MISC_CTL2 register (see
Table 130 on page 278). Once the maximum number of retries is completed, the QSpan
II discards the cycle and terminates the cycle on the QBus. Read cycles and delayed
write cycles on the QBus Slave Channel are terminated on the QBus with a bus error.
For posted writes to the Qx-FIFO, and if error logging is enabled, the QSpan II captures
the discarded transfer in the PCI Error log.
QSpan II User Manual 55
May 16, 2013
Chapter 4: The PCI Target Channel
This chapter describes the QSpan II’s PCI Target Channel. The following topics are
discussed:
“PCI Target Channel Architecture” on page 56
“Channel Description” on page 58
“Address Phase” on page 59
“Data Phase” on page 66
“Reads and PCI Transaction Ordering” on page 75
“QBus Arbitration and Sampling” on page 76
“Terminations” on page 78
4.1 Overview
An external PCI bus master can access a QBus slave through the QSpan II using its PCI
Target Channel (see Figure 5). The initialization of this channel is discussed in “PCI
Target Channel Initialization” on page 381.
Chapter 4: The PCI Target Channel
QSpan II User Manual56 May 16, 20 13
Figure 5: PCI Target Channel — Functional Diagram
4.2 PCI Target Channel Architecture
Figure 5 shows the PCI Target Channel in relation to the QBus and the PCI bus. The
arrows represent data flow. The QBus is shown as having one slave; the PCI bus is
shown with a single PCI master. The PCI Target Channel has the following
components:
•PCI Target Module
•Px-FIFO
•Pr-FIFO
QBus Master Module
4.2.1 PCI Target Module
QSpan II’s PCI Target Interface is a PCI Local Bus Specification 2.2 compliant port.
QSpan II does not implement SBO#, SDONE or PCI LOCK# functionality. A list of the
PCI signals supported by the QSpan II is in “PCI Bus Signals” on page 172.
The PCI Target Module accepts Type 0 Configuration cycles and ignores Type 1
Configuration cycles. Configuration cycles are not passed to the QBus (for information,
see “PCI Configuration Cycles Generated from the QBus” on page 108).
PCI
Target
Module
QBus
Master
Module
PCI Target Channel
PCI
Interface QBus
Interface
PCI
Bus QBus
Px-FIFO
Pr-FIFO
Posted Writes
256 Bytes
Prefetched Reads
256 Bytes
QBus
Slave
(DRAM)
PCI
Master
(DMA)
Chapter 4: The PCI Target Channel
QSpan II User Manual 57
May 16, 2013
4.2.2 Px-FIFO and Pr-FIFO
The Px-FIFO is a 256-byte buffer for posted writes from the PCI bus to the QBus. The
Px-FIFO can accept data from a PCI master while writing data to a QBus slave (see
“Posted Writes” on page 72).
The Pr-FIFO is a separate 256-byte buffer for read data from the QBus (see “Prefetched
Read Transactions” on page 74).
4.2.3 QBus Master Module
The QBus Master Module is a non-multiplexed 32-bit address, 32-bit data interface.
This module can be treated as a 32-bit, 16-bit, or 8-bit interface by programming the
DSIZE field of the PCI Target Image (see Table 17 on page 60).
The QBus Master Module can generate MC68360 (QUICC), MPC860 (PowerQUICC),
or M68040 cycles depending on the QBus Master mode selected at reset. This reset
option is determined jointly by the value of BDIP_ and SIZ[1] at reset. Table 15
presents the QBus Master mode options. For completeness, this table also includes the
QBus Slave Module options. The Master/Slave mode (MSTSLV) field in the
MISC_CTL register indicates the Master and Slave modes of the QBus (see Table 127
on page 274). The connections required for interfacing the QSpan II to an MC68360,
MPC860, and/or M68040 are given in Appendix C: “Typical Applications”
on page 359.
Table 15: Reset Options for QBus Master and Slave Modes
Reset sampling
Master Mode Slave Modesa
BDIP_ SIZ[1]
0 0 MC68360 MC68360 and
M68040
0 1 MC68360 MC68360 and
MPC860
1 0 M68040 MC68360 and
M68040
1 1 MPC860 MC68360 and
MPC860
a. This column is included because the Master mode options can restrict which slave option that can be used: the
M68040 Master mode is incompatible with the MPC860 Slave mode.
The QBus Master Module supports bursts reads and burst writes in
MPC860 mode only.
Chapter 4: The PCI Target Channel
QSpan II User Manual58 May 16, 20 13
4.2.3.1 QBus Data Parity Generation and Detection
The QBus Master Module supports the generation and detection of QBus data parity.
The use of QBus data parity is optional. The data parity is valid on the same clock cycle
as the QBus data. QSpan II supp orts Odd and Even parity, and is controlled by the QBus
Parity Encoding (QBUS_PAR) bit the in MISC_CTL2 register (see Table 130 on
page 278). The default is Even parity, which is the same as the PCI bus. The detection
of a QBus data parity error do es not affect the operation of the QSpan II. PCI bus parity
generation and detection is independent of QBus data parity generation and detection.
Four pins are used for the QBus Data Parity signals: DP[3:0]. When parity is set to
Even, the number of ones on the QBus Data lines (D[7:0]) and DP[0] equal an even
number. Similarly, for Odd parity, the number of ones on D[7:0] and DP[0] equal an
odd number.
DP[0] contains the parity for Data lines D[7:0]
DP[1] contains the parity for Data lines D[15:8]
DP[2] contains the parity for Data lines D[23:16]
DP[3] contains the parity for Data lines D[31:24]
The QBus Master Module generates the data parity when it completes a master write
cycle. If it detects a parity error during a master read cycle, it sets the QBus Data Parity
Error Status (QDPE_S) bit in the INT_STAT register (see Table 119 on page 260).
QSpan II can generate an external interrupt (INT# or QINT_) depending on the settings
of the QDPE_EN bit in the INT_EN register, and the QDPE_DIR bit in the INT_DIR
register (see Table 121 on page 266). Writing a 1 to the QDPE_S bit in the INT_STAT
register negates the interrupt and clears the status bit (see Ta ble 119 on page 260).
QSpan II only checks data parity on valid data. If a single byte transfer is completed on
the QBus, only the valid byte on the data bus is checked; for example, D[31:24].
4.3 Channel Description
The operation of the PCI Target Channel is described in the following sections by
tracing the path of a transaction from the PCI bus to the QBus. This is completed by
dividing a transaction into the following components:
Address Phase: This section describes how PCI bus accesses are decoded and how
address information from the PCI bus is passed through to the QBus.
Data Phase: This section describes endian mapping and byte-lane translation
through the PCI Target Channel.
QBus Arbitration and Sampling: This section describes QBus arbitration.
Terminations: This section explains how terminations from the QBus are
communicated back to the master on the PCI bus. It describes how the PCI Target
Module handles different terminations (for example, retries or target-aborts). This
section also explains the conditions that drive the terminations the QSpan II issues
as a PCI target, and error logging mechanisms for posted writes.
Chapter 4: The PCI Target Channel
QSpan II User Manual 59
May 16, 2013
4.4 Address Phase
4.4.1 Transaction Decoding
All decoding by the PCI Target Module is based on the address and command
information produced by a PCI bus master. The PCI Tar ge t Modu le clai m s a cy cle i f
there is an address driven on the PCI bus that matches an image programmed into the
PCI Target Image registers. The parameters of a Target Image must not overlap with the
4 Kbytes of QSpan II Register Space or the other target image. The parameters for
register accesses are discussed in “Register Access from the PCI Bus” on page 105.)
The type of cycle generated on the QBus is determined by the Target Image selected
and C/BE[3:0]. A Target Image is a set of parameters that determines what addresses
are decoded on the PCI bus and how cycles are translated from the PCI bus to the QBus.
Two Target Images of equal capability are provided so that PCI Masters can quickly
access different QBus devices, or the same device in different ways without having to
reconfigure QSpan II registers. The two Target Images are independent from one
another.
For example, one Target Image can be set-up to access 1 Mbyte of 16-bit SRAM on the
QBus using delayed writes, while the other can access 64 Mbytes of 32-bit SDRAM on
the QBus with posted writes. PCI Masters do not need to reconfi gure QSpan II registers
to access either of these devices. For a third type of access, it would be necessary to
share one of the Target Images.
The following tables summarize the PCI Target Image control and address fields.
Table 16: Address Fields for PCI Target Image
Field Description Image Register See
Base Address
(BA[31:16]) Address lines compared in decoding 0 PCI_BST0 or
PBTI0_ADD Table 75 on
page 208 or
Table 90 on
page 224
1 PCI_BST1 or
PBTI1_ADD Table 77 on
page 210 or
Table 93 on
page 228
Block Size
(BS[3:0]) Determines the number of AD lines
that are examined when decoding
accesses from the PCI bus.
0 PBTI0_CTL Table 89 on
page 222
1 PBTI1_CTL Table 92 on
page 226
Chapter 4: The PCI Target Channel
QSpan II User Manual60 May 16, 20 13
PCI Address Space
(PAS) Memory space or I/O space 0 PCI_BST0 or
PBTI0_CTL Table 75 on
page 208 or
Table 89 on
page 222
1 PCI_BST1 or
PBTI1_CTL Table 77 on
page 210 or
Table 92 on
page 226
Translation Address
(TA[31:16]) Address bits that are substituted to
generate the QBus address 0 PBTI0_ADD Table 90 on
page 224
1 PBTI1_ADD Table 93 on
page 228
Table 17: Cont rol Fields for PCI Target Image
Field Description Image Register See
Image Enable (EN) Enable bit 0 PBTI0_CTL Table 89 on
page 222
1 PBTI1_CTL Table 92 on
page 226
Posted Write Enable
(PWEN) Determines whether writes are posted
or processed as delayed transactions 0 PBTI0_CTL Table 89 on
page 222
1 PBTI1_CTL Table 92 on
page 226
Transaction Code
(TC[3:0]) Transaction code generated on the
QBus 0 PBTI0_CTL Table 89 on
page 222
1 PBTI1_CTL Table 92 on
page 226
Port Size (DSIZE) QBus destination port size 0 PBTI0_CTL Table 89 on
page 222
1 PBTI1_CTL Table 92 on
page 226
Prefetch Read Enable
(PREN) Determines whether the QSpan II
prefetches data on the QBus 0 PBTI0_CTL Table 89 on
page 222
1 PBTI1_CTL Table 92 on
page 226
Table 16: Address Fields for PCI Target Image (Continued)
Field Description Image Register See
Chapter 4: The PCI Target Channel
QSpan II User Manual 61
May 16, 2013
A PCI Target Image occupies a range of addresses within PCI Memory or I/O space.
The PCI Address Space bit determines whether the T a rget Image lies in PCI Memory or
I/O space. The range of addresses is specified by the base address field and the block
size field. Up to 2 Gbytes of PCI memory per image can reside on the QBus.
Burst Write Enable
(BRSTWREN) Determines whether the QSpan II burst
writes data on the QBus 0 PBTI0_CTL Table 89 on
page 222
1 PBTI1_CTL Table 92 on
page 226
Invert Endianness
(INVEND) Determines whether the QSpan II
inverts the endian setting of the
QB_BOC bit in the MISC_CTL
register
0 PBTI0_CTL Table 89 on
page 222
1 PBTI1_CTL Table 92 on
page 226
Prefetch Count
(PRCNT[5:0]) Determines the amount of data the
QSpan II prefetches on the QBus. 0 and/or
1MISC_CTL Table 127 on
page 274
PCI Ta rget Channel
Prefetch is image-based
(PTP_IB)
Determines whether image-based
prefetching is enabled 1 MISC_CTL2 Table 130 on
page 278
Prefetch Count
(PR_CNT2[5:0]) Determines the amount of data that the
QSpan II prefetches on the QBus for
accesses to Image 1, if PTP_IB=1
1 MISC_CTL2 Table 130 on
page 278
QBus Burst 4 Data
Phases (BURST_4) Determines whether the QBus bursts
four data phases, versus two or three
data phases
0 and 1 MISC_CTL2 Table 130 on
page 278
QBus Prefetch Single
Dataphase (PR_SING) Determines whether the QSpan II will
generate single cycles to prefetch data
as an MPC860 master
0 and 1 MISC_CTL2 Table 130 on
page 278
Keep Bus Busy for
Back-to-back cycles
(KEEP_BB)
Determines whether Bus Busy is
asserted for multiple cycles on the
QBus
0 and 1 MISC_CTL2 Table 130 on
page 278
PCI Target Images can be enabled or disabled by using the image enable
bit. Disabling both PCI Target Images disables the PCI Target Channel.
For more information about register settings that affect the PCI Target
Channel’s operation, see the Miscellaneous Control registers —
MISC_CTL (see Table 127 on page 274) and MISC_CTL2 (see
Table 130 on page 278).
Table 17: Control Fields for PCI Target Image (Continued )
Field Description Image Register See
Chapter 4: The PCI Target Channel
QSpan II User Manual62 May 16, 20 13
There are constraints on the possible values of the block size and the base address. The
block size must be one of the 16 block sizes listed in Table 18 on page 64. The base
address must be aligned to a combination of the upper address lines between AD31 and
AD16. The base address must be a multiple of the block size. For example, a
128-Mbyte image must be aligned to a 128-Mbyte boundary.
Address decoding is performed by decoding the most significant address lines as a
function of the block size. For a 128-Mbyte PCI Target Image, the PCI Target Module
only needs to decode the top five PCI address lines to know whether this image has
been accessed. For a 64 Kbyte image, the PCI Target Module needs to decode the top 16
PCI address lines.
When one of its PCI Target Images is accessed, the QSpan II responds with DEVSEL#
within two clocks of FRAME#. This makes the QSpan II a medium-speed device, as
indicated by the Device Select (DEVSEL) field in the PCI_CS register (see Table 70 on
page 201).
As a PCI target, the QSpan II responds to the following command types:
I/O Read
I/O Write
Memory Read
Memory Write
Configuration Type 0 Read
Configuration Type 0 Write
Memory Read Multiple (aliased to Memory Read)
Memory Read Line (aliased to Memory Read)
Memory Write and Invalidate (aliased to Memory Write)
4.4.2 Address Translation
Figure 6 illustrates the general implementation of address translation in the QSpan II
PCI Target Channel.
Chapter 4: The PCI Target Channel
QSpan II User Manual 63
May 16, 2013
Figure 6: Address Generator for PCI Target Channel Transfers
The Address Generator produces the QBus address using three inputs: the address
generated by the PCI master (AD[31:0]), the block size of the PCI Target Image (BS
field of the Target Image), and the translation address of the PCI Target Image (TA).
The translation address is a 16-bit number whose upper bits specify the location of the
Target Image on the QBus. If the translation address is programmed with the same value
as that of the base address, then the PCI address is not translated but applied directly to
the QBus transaction.
The most significant bits of the translation address are used by the Address Generator as
determined by the programming of the image’s block size. The number of these bits
used depends on the pro gramming of the BS bit. The correlatio n between block size and
the number of most significant TA bits used in generating the QBus address is shown in
Table 18. With a 64 Kbyte block size, the Address Generator copies the entire
translation address into the QBus address, but only copies the lower 16 bits from the
PCI address signal (for example, the Address Generator translates AD[31:16]). With a
2 Gbyte block size, the Address Generator copies all but bit 31 from the PCI address
signal (for example, the Address Generator translates AD[31] only), and uses the top
translation address bit as bit 31 of the QBus address.
This manual adopts the convention that the most significant bit is always
the largest number. MPC860 designers must ensure that they connect
their pins accordingly. For example, pin A[31] on the QSpan II connects
to pin A[31] on the MC68360 bus, but connects to pin A[0] on the
MPC860 bus. This applies to all MPC860 buses (D[31:0], AT[3:0],
TSIZ[1:0]) not only the address bus.
The QSpan II’s chip select inputs (CSREG_, CSPCI_) must not be
asserted when the QSpan II is initiating a cycle on the QBus.
Translation Address PCI Address Block Size
Address Generator
QBus Address
Chapter 4: The PCI Target Channel
QSpan II User Manual64 May 16, 20 13
4.4.3 Transaction Codes on the QBus
The address supplied on the A[31:0] lines on the QBus is the result of the address
translation described in the previous section. QSpan II also allows the user flexibly to
generate various encodings on the QSpan II’s TC[3:0] lines. The TC[3:0] lines can be
connected to the FC[3:0] lines of the MC68360 bus, the AT[0:3] lines of the MPC860
bus, and a subset of the TT[1:0] and TM[2:0] lines of the M68040 bus. QSpan II copies
the values from the TC field of the PCI Target Image of the current transaction to the
TC[3:0] lines of the QBus. This gives the user additional control over the address
information provided on the QBus.
Table 18: Translation of PCI Bus Address to QBus Address
BS in PBTI0_CTL or
PBTI1_CTL Block Size PCI Address Bits
Translated Translation Address Bits
Copied
0000 64 Kbytes AD31–AD16 TA31–TA16
0001 128 Kbytes AD31–AD17 TA 31–TA17
0010 256 Kbytes AD31–AD18 TA 31–TA18
0011 512 Kbytes AD31–AD19 TA31–TA19
0100 1 Mbyte AD31–AD20 TA31–TA20
0101 2 Mbytes AD31–AD21 TA31–TA21
0110 4 Mbytes AD31–AD22 TA31–TA22
0111 8 Mbytes AD31–AD23 TA31–TA23
1000 16 Mbytes AD31–AD24 TA31–TA24
1001 32 Mbytes AD31–AD25 TA31–TA25
1010 64 Mbytes AD31–AD26 TA31–TA26
1011 128 Mbytes AD31–AD27 TA31–TA27
1100 256 Mbytes AD31–AD28 TA31–TA28
1101 512 Mbytes AD31–AD29 TA31–TA29
1110 1 Gbyte AD31–AD30 TA31–TA30
1111 2 Gbytes AD31 TA31
Chapter 4: The PCI Target Channel
QSpan II User Manual 65
May 16, 2013
4.4.4 PCI BIOS Memory Allocation
The PCI Target Image registers used by the QSpan II to decode PCI accesses work
differently depending on the EEPROM implementation and the use of the PCI Access
Disabled (PCI_DIS) bit in MISC_CTL2 (see Table 130 on page 278). There are three
possible cases:
1. Case 1: The PCI_BSTx register is enabled by the EEPROM (see Table 75 on
page 208 and Table 77 on page 210). For PCI Targ et Image 0, th is means that bit 5
of byte 7 in the EEPROM is 1. For PCI Target Image 1, this means that bit 7 of byte
8 in the EEPROM is 1 (see Table 44 on page 125).
2. Case 2: The PCI_BSTx register is not enabled (see Table 75 on pa ge 208 and
Table 77 on page 210). For PCI Target Image 0, this means that bit 5 of byte 7 in
the EEPROM is 0. For PCI Ta rget Image 1, this means that bit 7 of byte 8 in the
EEPROM is 0 (see Table 44 on page 125).
3. Case 3: By setting the power-up option, PCI_DIS, the QSpan II will retry all PCI
accesses, and the QBus Host can program the registers and then clear the PCI_DIS
bit in MISC_CTL2. Once cleared, this enables the PCI Host to read the
Configuration registers.
4.4.4.1 Block Size and PCI Address Space
If PCI address programming from the EEPROM is enabled (Case 1), the Block Size and
PCI Address Space (PAS) fields are set from the EEPROM, and they are read only . (The
PAS bit can be read from either the PCI_BSTx or the PBTIx_CTL register.)
If the reset state of the Block Size and Address Space fields is zero (Case 2), these fields
are only writable from the PBTIx_CTL registers.
4.4.4.2 Base Address
If PCI address information is loaded from an EEPROM (Case 1), the base address of the
Target Image can only be set through the PCI_BSTx register (for example, BA[31:16]
of PCI_BST0 or PCI_BST1). The base address can be read from either the PCI_BSTx
register or the PBTIx_ADD register.
The PCI BIOS uses the PCI_BSTx registers to determine the address allocation for the
QSpan II-based board. It does this by writing all 1s to the BA field of the PCI_BSTx
register and then reading back from the same location. The number of bits in the BA
field of the PCI_BSTx register that are writable is determined by the Target Image’s
block size (BS[3:0] field in the PBTIx_CTL register).
For example, if the PCI Target Image is programmed to a block size of 128 Mbytes,
then the BS field in the PBTIx_CTL register has been programmed to all 1s (see
Table 18 on page 64). This means that only the most significant five bits of the BA field
of PCI_BSTx register are writable. When the BIOS reads back from the BA field in the
PCI_BSTx register, the read returns only the most significant five bits of BA as 1,
indicating a 128 Mbyte image size.
Chapter 4: The PCI Target Channel
QSpan II User Manual66 May 16, 20 13
When PCI address information is not loaded from an EEPROM or initiated by the
processor on the QBus; the base address can only be set through the PBTIx_ADD
registers. The PBTIx_ADD registers do not support the image-sizing functionality
described in the previous paragraph.
4.5 Data Phase
4.5.1 Endian Mapping
This section describes how the QSpan II translates cycles from the PCI bus to the QBus.
The PCI bus is always a Little-Endian environment. The QBus can be configured as
Little-Endian or Big-Endian, depending on the value of the QBus Byte Ordering
Control bit (QB_BOC) in the MISC_CTL register (see Table 127 on page 274). The
default mode for the QBus is Big-Endian. This global ordering can be inverted on an
image-by-image basis by programming the INVEND bit of the PBTIx_CTL register.
QSpan II translates byte-lane ordering when the QBus is Big-Endian, while preserving
the addressing of bytes.
When the QBus is Little-Endian — according to QB_BOC and INVEND — the
QSpan II preserves byte-lane ordering, while translating the addressing of bytes. (The
QB_BOC bit affects transactions in all channels whereas the INVEND bit only affects
the PCI Target Channel.)
PCI bus transactions have the following char acteristics:
They can be translated as 32-bit, 16-bit, or 8-bit on the QBus.
The data width of the QBus transaction is controlled by the DSIZE field of the PCI
bus Target Image Control register.
With 16-bit peripherals, the y can be 8-bits or 16-bits wide.
With 8-bit peripherals, they can be 8-bits wide.
Packing and unpack ing of data performed by the QBus Master Module is a
function of byte-enab l es (BE[3:0]) and the port size.
4.5.1.1 Write Cycle Mapping for PCI Target Channel
This section describes write cycle mapping as a function of port size.
The PCI bus and Motorola processors differ in the way they order and
address bytes. These differences are explained in Appen dix E: “Endian
Mapping” on page 389.
All tri-byte, misaligned and non-contiguous byte write operations on the
PCI bus are performed as a series of 8-bit write operations on the QBus.
Chapter 4: The PCI Target Channel
QSpan II User Manual 67
May 16, 2013
32-Bit QBus Port
Tables 19 and 20 describe write transfers of various sizes to 32-bit peripherals on the
QBus.
The following table describes mapping of 8, 16, and 32-bit write transfers through the
PCI Target Channel with the QBus set to Little-Endian. (The byte lane ordering is
preserved in Little-Endian mode.)
The following table describes mapping of 8, 16, and 32-bit write transfers through the
PCI Target Channel in Big-Endian mode to 32-bit QBus peripherals. (The addressing of
bytes is preserved in Big-Endian mode.)
Table 19: Little-Endian PCI Target Write Cycle Mapping — 32-Bit QBus Port
Transfer size
PCI bus QBus
BE[3:0]# D[31:0] SIZ[1:0] A[1:0] D[31:0]
8 bits 0111 B3 xx xx xx 01 00 B3 xx xx xx
8 bits 1011 xx B2 xx xx 01 01 B2 B2 xx xx
8 bits 1101 xx xx B1 xx 01 10 B1 xx B1 xx
8 bits 1110 xx xx xx B0 01 11 B0 B0 xx B0
16 bits 0011 B3 B2 xx xx 10 00 B3 B2 xx xx
16 bits 1100 xx xx B1 B0 10 10 B1 B0 B1 B0
32 bits 0000 B3 B2 B1 B0 00 00 B3 B2 B1 B0
Table 20: Big-Endian PCI Target Write Cycle Mapping — 32-Bit QBus Port
Transfer size
PCI bus QBus
BE[3:0]# D[31:0] SIZ[1:0] A[1:0] D[31:0]
8 bits 1110 xx xx xx B0 01 00 B0 xx xx xx
8 bits 1101 xx xx B1 xx 01 01 B1 B1 xx xx
8 bits 1011 xx B2 xx xx 01 10 B2 xx B2 xx
8 bits 0111 B3 xx xx xx 01 11 B3 B3 xx B3
16 bits 1100 xx xx B1 B0 10 00 B0 B1 xx xx
16 bits 0011 B3 B2 xx xx 10 10 B2 B3 B2 B3
32 bits 0000 B3 B2 B1 B0 00 00 B0 B1 B2 B3
Chapter 4: The PCI Target Channel
QSpan II User Manual68 May 16, 20 13
16-Bit QBus Port
16-bit QBus port transfers are explained in terms of the 32-bit transfers described in
Tables 19 and 20. The first of these operations involves unpacking data.
A 32-bit write operation to a QBus peripheral with a 16-bit QBus port size is
performed as two 16-bit write operations to a 32-bit peripheral.
A 16-bit write operation to a QBus peripheral with a 16-bit QBus port size is
performed as a 16-bit write operation to a 32-bit peripheral.
An 8-bit write operation to a QBus peripheral with a 16-bit QBus port size is
performed as an 8-bit write operation to a 32-bit peripheral.
8-bit QBus port
8-bit QBus port transfers are explained in terms of the 32-bit transfers described in
Tables 19 and 20 . The first two operations involve unpacking data.
A 32-bit write operation to a QBus peripheral with an 8-bit QBus port size is
performed as four 8-bit write operations to a 32-bit peripheral.
A 16-bit write operation to a QBus peripheral with an 8-bit QBus port size is
performed as two 8-bit write operations to a 32-bit peripheral.
An 8-bit write operation to a QBus peripheral with an 8-bit QBus port size is
performed as an 8-bit write operation to a 32-bit peripheral.
All tri-byte, misaligned and non-con tiguous byte write operations are performed as
a series of 8-bit write operations to a 32-bit peripheral.
4.5.1.2 Read Cycle Mapping for PCI Target Channel
This section describes cycle mapping and packing of data by the QBus Master Module.
32-bit QBus Port
Tables 21 and 22 describe transfers of various sizes to 32-bit peripherals.
Chapter 4: The PCI Target Channel
QSpan II User Manual 69
May 16, 2013
The following table describes mapping of 8-bit, 16-bit, and 32-bit read trans fers through
the PCI Target Channel in Little-Endian mode to 32-bit QBus peripherals. The
byte-lane ordering is preserved in Little-Endian mode.
The following table describes mapping of 8-bit, 16-bit, and 32-bit read tran sfers through
the PCI Target Channel in Big-Endian mode from 32-bit QBus peripherals. The
addressing of bytes is preserved in Big-Endian mode.
Table 21: Little-Endian PCI Target Read Cycle Mapping — 32-Bit QBus Port
Transfer size
PCI bus QBus
BE[3:0]# D[31:0] SIZ[1:0] A[1:0] D[31:0]
8 bits 0111 B3 xx xx xx 01 00 B3 xx xx xx
8 bits 1011 xx B2 xx xx 01 01 xx B2 xx xx
8 bits 1101 xx xx B1 xx 01 10 xx xx B1 xx
8 bits 1110 xx xx xx B0 01 11 xx xx xx B0
16 bits 001 1 B3 B2 xx xx 10 00 B3 B2 xx xx
16 bits 1100 xx xx B1 B0 10 10 xx xx B1 B0
32 bits 0000 B3 B2 B1 B0 00 00 B3 B2 B1 B0
Table 22: Big-Endian PCI Target Read Cycle Mapping — 32-Bit QBus Port
Transfer size
PCI bus QBus
BE[3:0]# D[31:0] SIZ[1:0] A[1:0] D[31:0]
8 bits 1110 xx xx xx B0 01 00 B0 xx xx xx
8 bits 1101 xx xx B1 xx 01 01 xx B1 xx xx
8 bits 1011 xx B2 xx xx 01 10 xx xx B2 xx
8 bits 0111 B3 xx xx xx 01 11 xx xx xx B3
16 bits 1100 xx xx B1 B0 10 00 B0 B1 xx xx
16 bits 0011 B3 B2 xx xx 10 10 xx xx B2 B3
32 bits 0000 B3 B2 B1 B0 00 00 B0 B1 B2 B3
All tri-byte, misaligned and n on- contig uous by te delayed read operations
from a peripheral with a 32-bit QBus port size are performed as a series
of 8-bit read operations would be from a 32-bit peripheral.
Chapter 4: The PCI Target Channel
QSpan II User Manual70 May 16, 20 13
16-Bit QBus Port
Tables 23 and 24 describe 8-bit and 16-bit read transfers from 16-bit QBus peripherals.
The following table describes map pin g of 8-bit and 16-bit read transfers through the
PCI Target Channel in Little-Endian mode from 16-bit QBus peripherals. The byte lane
ordering is preserved in Little-Endian mode.
The following table describes map pin g of 8-bit and 16-bit read transfers through the
PCI Target Channel in Big-Endian mode from 16-bit QBus peripherals. The addressing
of bytes is preserved in Big-Endian mode.
Table 23: Little-Endian PCI Target Read Cycle Mapping — 16-Bit QBus Port
Transfer size
PCI bus QBus
BE[3:0]# D[31:0] SIZ[1:0] A[1:0] D[31:0]
8 bits 0111 B3 xx xx xx 01 00 B3 xx xx xx
8 bits 1011 xx B2 xx xx 01 01 xx B2 xx xx
8 bits 1101 xx xx B1 xx 01 10 B1 xx xx xx
8 bits 1110 xx xx xx B0 01 11 xx B0 xx xx
16 bits 0011 B3 B2 xx xx 10 00 B3 B2 xx xx
16 bits 1100 xx xx B1 B0 10 10 B1 B0 xx xx
Table 24: Big-Endian PCI Target Read Cycle Mapping — 16-Bit QBus Port
Transfer size
PCI bus QBus
BE[3:0]# D[31:0] SIZ[1:0] A[1:0] D[31:0]
8 bits 1110 xx xx xx B0 01 00 B0 xx xx xx
8 bits 1101 xx xx B1 xx 01 01 xx B1 xx xx
8 bits 1011 xx B2 xx xx 01 10 B2 xx xx xx
8 bits 0111 B3 xx xx xx 01 11 xx B3 xx xx
16 bits 1100 xx xx B1 B0 10 00 B0 B1 xx xx
16 bits 0011 B3 B2 xx xx 10 10 B2 B3 xx xx
All tri-byte, misaligned and non-contiguous byte read op erations from a
peripheral with a 16-bit QBu s port size are performed like a series of 8-bi t
read operations from a 16-bit peripheral.
Chapter 4: The PCI Target Channel
QSpan II User Manual 71
May 16, 2013
A 32-bit read operation from a peripheral with a 16-bit QBus port size is performed as
two 16-bit read operations from a peripheral with a 16-bit QBus port size.
8-Bit QBus Port
The following table describes mapping of 8-bit read transfers through the PCI Target
Channel in Little-Endian mode from 8-bit QBus peripherals. The byte-lane ordering is
preserved in Little-Endian mode.
The following table describes mapping of 8-bit read transfers through the PCI Target
Channel in Big-Endian mode from 8-bit QBus peripherals. The addressing of bytes is
preserved in Big-Endian mode.
A 32-bit read operation from a peripheral with an 8-bit QBus port size is performed as
four 8-bit read operations from a peripheral with an 8-bit QBus port size.
A 16-bit read operation from a peripheral with an 8-bit QBus port size is performed as
two 8-bit read operations from a peripheral with an 8-bit QBus port size.
Table 25: Little-Endian PCI Target Read Cycle Mapping — 8-Bit QBus Port
Transfer size
PCI bus QBus
BE[3:0]# D[31:0] SIZ[1:0] A[1:0] D[31:0]
8 bits 0111 B3 xx xx xx 01 00 B3 xx xx xx
8 bits 1011 xx B2 xx xx 01 01 B2 xx xx xx
8 bits 1101 xx xx B1 xx 01 10 B1 xx xx xx
8 bits 1110 xx xx xx B0 01 11 B0 xx xx xx
Table 26: Big-Endian PCI Target Read Cycle Mapping — 8-Bit QBus Port
Transfer size
PCI bus QBus
BE[3:0]# D[31:0] SIZ[1:0] A[1:0] D[31:0]
8 bits 1110 xx xx xx B0 01 00 B0 xx xx xx
8 bits 1101 xx xx B1 xx 01 01 B1 xx xx xx
8 bits 1011 xx B2 xx xx 01 10 B2 xx xx xx
8 bits 0111 B3 xx xx xx 01 11 B3 xx xx xx
All tri-byte, misaligned and non-contiguous byte read op erations from a
peripheral with an 8-bit QBus port size are performed like a series of 8-bit
read operations from an 8-bit peripheral.
Chapter 4: The PCI Target Channel
QSpan II User Manual72 May 16, 20 13
4.5.2 Data Path
This section explains how data flows between the PCI bus and the QBus through the
PCI Target Channel.
4.5.2.1 Posted Writes
If the Posted W rite Enable (PWEN) bit in the Target Image is 1, writes to the PCI Target
Module are posted into the Px-FIFO (see “Tran saction Decoding” on page 59). If the bit
is cleared, writes are treated as delayed transactions. The default setting for the PWEN
bit is 0, which is delayed transactions.
Write transfers are stored in the Px-FIFO (see “Px-FIFO and Pr-FIFO” on page 57 ).
Address and data are stored as separate entries in the Px-FIFO. For example, a single
data transaction is stored as two entries in the Px-FIFO — one for the translated address
and one for the data (see “Address Translation” on page 62). Any reprogramming of
PCI Target Image attributes will only be reflected in Px-FIFO entries queued after the
reprogramming. Transactions queued before the reprogramming are delivered to the
PCI bus with the PCI Target Image attributes that were in use before the
reprogramming.
QSpan II never packs data in the Px-FIFO. For example, two non-burst 16-bit data beats
are not packed as a single 32-bit data entry but as four separate entries in the Px-FIFO
(32-bit address, 16-bit data, 32-bit address, 16-bit data).
Acceptance of Burst Writes by the PCI Target Module
The PCI Target Module can accept burst write transactions from PCI bus Masters. This
section explains the following about PCI burst writes: when PCI bursts are accepted,
how they are stored, and how data is transferred on the QBus.
QSpan II will not accept a PCI burst write under the following conditions:
1. If posted writes for the selected Target Image are disabled (see Table 84 on
page 217 or T able 92 on page 226), then each successive data phase is processed as
a delayed single write. When the write completes on the QBus, the QSpan II issues
a Target-Completion the next time the transfer is attempted by the external PCI
master. Therefore, for each data phase in the burst, the external PCI master will see
a series of retries and then one Target-Completion.
2. If the Px-FIFO fills while a burst is in progress, the PCI Target Module generates a
Target-Disconnect.
3. If there are fewer data entries available in the Px-FIFO than specified by the
cacheline — CLINE[1:0] field of the PCI_MISC0 register — and a PCI master
attempts a new burst to the QSpan II, the external PCI master is retried.
4. The PCI Target Module only accepts linear burst address incrementing. Any
transfers requiring other addressing modes are disconnected after the first data
phase.
For more information, see “Terminations driven by the PCI Target Module” on p age 80.
Chapter 4: The PCI Target Channel
QSpan II User Manual 73
May 16, 2013
The Px-FIFO stores the address and data entries of PCI bursts. For example, if a burst of
four is received by the PCI Target Module, the QSpan II stores the burst as five new
entries of the following types: address, data, data, data, data. Because the QBus Master
Module can write data at the same time as the PCI Target Module accepts data, the
Px-FIFO might not con tain these five entries by the end o f the burst — some of the data
may already have been written to the QBus before the burst completes on the PCI bus.
Bursting on the QBus
If the Burst Write Enable (BRSTWREN) bit of the selected PCI Target Image is 1, the
QSpan II will burst data from the Px-FIFO onto the QBus. When enabled, all byte-lanes
are assumed to be active for data written to the image. Generation of burst writes is only
supported while in MPC860 Master mode (see Table 15 on page 57).
Burst length on the QBus is controlled by the BDIP_ signal: by ne gating BDIP_ the
QSpan II signals the QBus slave that the current data beat is the second last beat of the
transaction. This allows the QSpan II to perform bursts of two, three, or four data beats.
QSpan II can be programmed to generate a burst of four data beats to be compatible
with the MPC860’s memory controller (UPM). This can be completed by setting the
QBus Burst Four Dataphases (BURST_4) bit in the MISC_CTL2 register (see
Table 130 on page 278).
If the write transfer is not cacheline aligned, then the QSpan II will perform single
writes up until a cacheline boundary. Similarly, if a PCI write transaction completes, the
QSpan II will perform single write cycles for the entries that remained in the Px-FIFO
at a non-cacheline aligned address.
4.5.2.2 Delayed Writes
If a write is attempted when posted writes are disabled for the PCI Target Image
(PWEN is set to 0), or the address space bit is set to 1 (for I/O transfers), then write
cycles are treated as delayed transactions. During a delayed write transaction the PCI
master is retried until the transaction completes on the QBus. If the PCI transaction
completes normally on the QBus, then when the PCI bus master retries the same
transaction — qualified by the latched address and command information — the
original PCI master is given a normal cycle termination. If the QBus transaction does
not complete normally, then the appropriate termination is communicated back to the
PCI master (see “Terminations” on page 78).
The KEEP_BB bit in the MISC_CTL2 register (see Table 130 on
page 278) is not supported for DMA operation. As such, do not set this bit
when the QSpan II DMA channel is used with the PowerQUICC memory
controller (UPM).
Chapter 4: The PCI Target Channel
QSpan II User Manual74 May 16, 20 13
4.5.2.3 Single Read Transactions
When the QSpan II receives a target read request, it latches the address and C/BE#
information and retries the PCI master. QSpan II then becomes QBus master and
initiates a read on the QBus. The external PCI master is retried until the read is
completed on the QBus. When the external PCI master retries the same transaction —
qualified by the latched information — it is provided with the data and the transaction
terminates normally on the PCI bus. If the QBus transaction does not complete
normally, then the appropriate termination is communicated back to the PCI bus master
(see “Term i nations” on page 78).
4.5.2.4 Prefetched Read Transactions
QSpan II supports different prefetch data amounts based on the PCI target image
accessed during a read of the PCI Target Channel. QSpan II initiates a prefetch read
transaction on the QBus if the following conditions are met:
1. The PREN bit in the selected Target Image must be 1.
2. The Prefetch Read Byte Count (PRCNT[5:0]) bit in the MISC_CTLx register must
be programmed. The PRCNT2[5:0] and PTP_IB bits in the MISC_CTL2 register
can also be programmed to enable image-based prefetching (see Table 130 on
page 278).
3. The PCI master must keep FRAME# asserted when IRDY# is as serted (for
example, PCI burst read cycle).
QSpan II will read the amount of data specified in the appropriate PRCNTx[5:0] field of
the MISC_CTLx register (see Table 127 on page 274 and Table 130 on page 278).
QSpan II retries the PCI master until read data is available in the Pr-FIFO.
If the PREN bit is cleared, which is the default setting, the transfer is processed as a
delayed single read (see “Single Read Transactions” on page 74). QSpan II will
prefetch whether it is in MC68360, MPC860, or M68040 Master mode (see “QBus
Master Module” on page 57). However, it will only prefetch with burst reads on the
QBus when it is MPC860 Master mode. If the external QBus slave does not support
bursting, setting the QBus Prefetch Signal Dataphase (PR_SING) bit will cause the
QSpan II to prefetch in MPC860 mode using only single reads.
If a read-request is not cacheline aligned, then the QSpan II will perform single beat
transactions on the MPC860 bus until it reaches a cacheline boundary. The QBus
Master Module, as MPC860 master, only performs burst reads at cacheline boundaries.
This feature makes QSpan II burst reads compatible with the MPC860 UPM. The
module requests the bus for a burst when there is enough room in the Pr-FIFO for an
entire cacheline of data.
The PR_SING bit in the MISC_CTL2 register supports QSpan II prefetching as single
or burst cycles in the PCI Target Channel. The PR_SING bit should be set to a 1 if the
QBus memory does not support bursting when the QSpan II is powered up as an
MPC860 master (see Table 130 on page 278).
Chapter 4: The PCI Target Channel
QSpan II User Manual 75
May 16, 2013
4.5.3 Parity Monitoring by PCI Target Module
The PCI Target Module monitors parity during the address phase of transactions and
during the data phase of write transfers. For example, the QSpan II compares the PAR
signal with the parity o f AD[31:0] and C/BE[3:0 ]. The PAR signal provides ev en parity
for C/BE#[3:0] and AD[31:0]. QSpan II drives PAR when it provides data as a target
during a read.
If the PCI Target Module detects an address or data parity error during a write, it sets the
Detected Parity Error (D_PE) bit in the PCI_CS register (see Table 70 on pa ge 201)
regardless of the PERESP setting in the PCI_CS register. For more information about
parity errors and the D_PE bit, see “Parity Monitoring by PCI Master Module” on
page 50. If the QSpan II signals SERR#, it sets the S_SERR bit in the PCI_CS register.
Address parity errors are reported if Parity Error Response (PERESP) and SERR#
Enable (SERR_EN) are set in the PCI_CS register (see Table 70 on page 201). Address
parity errors are reported by the QSpan II by asserting the SERR# signal and setting the
S_SERR (signaled SERR#) bit in the PCI_CS register. Assertion of SERR# can be
disabled by clearing the SERR_EN bit in the PCI_CS register. An interrupt may be
generated, and regardless of whether assertion of SERR# is enabled or not, the QSpan II
does not respond to the access with DEVSEL#. Normally, the master of the transaction
terminates the cycle with a Master-Abort.
The PERESP bit in the PCI_CS register af fects how the QSpan II responds to PCI parity
errors. If the PERESP bit and the SERR_EN bit are set, the QSpan II reports address
parity errors by asserting SERR# and setting the S_SERR bit in the PCI_CS register. If
the PERESP bit is set the QSpan II reports data parity errors (during writes) by asserting
PERR#.
4.6 Reads and PCI Transaction Ordering
PCI T ransaction Ordering rules affect the relationship between delayed reads in the PCI
Target Channel and posted writes in the PCI Target Channel. These rules also affect the
relation between delayed reads in the PCI Tar get Channel and posted writes in the QBus
Slave Channel.
When a read request is latched, the PCI Ta rget Module retries non-register accesses to
the PCI Target Module until the read completes on the QBus. Once the read completes
on the QBus, the QSpan II ensures that all writes previously posted in the Qx-FIFO
complete on the PCI bus before the read data is passed back to the PCI bus master that
initiated the read transaction. During the period when the Qx-FIFO is being emptied,
attempts to access the QBus Slave Channel are retried (register accesses are not
affected).
The following list summarizes the sequence of events:
1. The PCI Target Module receives a read request from a PCI master, which it latches.
2. The PCI Target Module retries all non-register accesses.
3. The PCI Target Channel empties the Px-FIFO.
Chapter 4: The PCI Target Channel
QSpan II User Manual76 May 16, 20 13
4. The QBus Master Module completes the read on the QBus.
5. The QBus Slave Module retries all non-register accesses.
6. The Qx-FIFO is emptied.
7. The PCI Target Module allows the read to complete on the PCI bus.
8. The PCI Target Module allows posted writes to the Px-FIFO, even if the delayed
read has not completed.
9. The QBus Slave Module allows posted writes to the Qx-FIFO.
Similar principles apply to QBus Slave Channel reads (see “Delayed Reads and PCI
Transaction Ordering” on page 49). The IDMA Channel is independent from the PCI
transaction ordering rules that affect the QBus Slave Channel and the PCI Target
Channel.
4.6.1 Transaction Ordering Disable Option
QSpan II has a register option to disable transaction ordering between the PCI Target
Channel and the QBus Slave Channel. The No Transaction Ordering (NOTO) bit in
MISC_CTL2 register is used for this purpose (see “MISC_CTL2 Description” on
page 278). When this bit is set, a read in one channel is unaffected by posted writes in
the other channel. This feature improves system performance, especially when using the
DMA and where stri ct tran s action ordering is not required.
4.7 QBus Arbitration and Sampling
The QBus Master Module requests the QBus when there is a read request or when there
is a sufficient number of entries in the Px-FIFO (see “Acceptance of Burst W rites by the
PCI Target Module” on page 72).
4.7.1 MC68360 Bus Arbitration
When the QSpan II requires control of the MC68360 bus, it requests the bus by
asserting Bus Request (BR_). When the QSpan II samples Bus Grant (BG_) asserted
and Bus Grant Acknowledge (BB_/BGACK_) negated, the QSpan II asserts
BB_/BGACK_ and negates BR_.
The QBus (MC68360) Master Module’s default arbitration mode is asynchronous: it
double-samples the BG_ and BB_/BGACK_ inputs using the falling and rising edge of
QCLK. The default mo de of operation can be modified with the QSpan II in order to
save one clock cycle during arbitration. To enable synchronous arbitration, set the
Synchronous Bus Grant (S_BG) bit and the Synchronous Bus Grant Acknowledge
(S_BB) bit to 1 in the MISC_CTL register (see T able 127 on page 274). The Arbitration
Synchronous Timing Mode (ASTM) bit in the MC68360 must be set for asynchronous
mode of operation by setting the ASTM bit to 0 in the MCR register.
Chapter 4: The PCI Target Channel
QSpan II User Manual 77
May 16, 2013
QSpan II can operate synchronously because all timing parameters can be met by the
MC68360. However, the MC68360 must be programmed for asynchronous mode in
order for the QSpan II to meet the MC68360’s input setup requirements. See
Appendix B: “Timing” on page 299 for the arbitration timing waveform.
QSpan II can hold onto the QBus for multiple transactions if the KEEP_BB bit is set in
the MISC_CTL2 register (see Table 130 on page 278). If set, this configuration
improves the performance of the PCI Target Channel and the DMA Channel by
eliminating the arbitration delay.
4.7.2 MPC860 Bus Arbitration
When the QSpan II requires control of the MPC860 bus, it arbitrates for the bus by
asserting BR_. When the QSpan II samples BG_ asserted and BB_/BGACK_ negated,
the QSpan II asserts BB_/BGACK_ and negates BR_.
The MPC860 Master Module’s default arbitration mode is synchronous. This default
mode can be overridden by setting S_BG and S_BB to 0 in the MISC_CTL register (see
Table 127 on page 274). Note that, except for termination signals with an MC68360,
and for arbitration, the QBus is always synchronous. See Appendix B: “Timing”
on page 299 for the arbitration timing waveform.
QSpan II can hold onto the QBus for multiple transactions if the KEEP_BB bit is set in
the MISC_CTL2 register (see Table 130 on page 278). If set, this configuration
improves the performance of the PCI Target Channel by eliminating the arbitration
delay.
If the MC68360’s processing core is disabled (Companion mode, Slave
mode) an external arbiter must be implemented to support arbitration
between the MC68360 and the QSpan II (for more information, see
Appendix C: “Typical Applications” on page 359).
QSpan II asserts BB_ one clock after BG_ in accordance with MPC860
arbitration requirements.
The KEEP_BB bit in the MISC_CTL2 register (see Table 130 on
page 278) is not supported for DMA operation. As such, do not set this bit
when the QSpan II DMA channel is used with the PowerQUICC memory
controller (UPM).
Chapter 4: The PCI Target Channel
QSpan II User Manual78 May 16, 20 13
4.7.3 M68040 Bus Arbitration
When the QSpan II requires control of the M68040 bus, it arbitrates for the bus by
asserting BR_. When the QSpan II samples BG_ asserted and BB_/BGACK_ negated,
the QSpan II asserts BB_/BGACK_ and negate s BR_.
The M68040 Master Module’s default operation is sync hronou s. This default mode can
be overridden by setting S_BG and S_BB to 0 in the MISC_CTL register (see
Table 127 on page 274). Note that, except for termination sig nals with an MC68360 and
arbitration, the QBus is always synchronous. See Appendix B: “Timing” on page 299
for the arbitration timing waveform.
QSpan II can hold onto the QBus for multiple transactions if the KEEP_BB bit is set in
the MISC_CTL2 register (see Table 130 on page 278). If set, this configuration
improves the performance of the PCI Target Channel and the DMA Channel by
eliminating the arbitration delay.
4.8 Terminations
4.8.1 QBus Master Module Terminations
This section explains the QBus Master Module’s handling of cycle termination for the
MC68360, MPC860 and M68040 buses.
4.8.2 MC68360 Cycle Terminations
When a transaction is completed, BB_/BGACK_ is negated by the QBus Mast er
Module on the rising clock edge and tristated on the next falling clock edge.
Termination of MC68360 cycles is describe d in Table 27. The QBus Mas te r Module
samples all of the MC68360 termination signals on the falling edge of QCLK. In
contrast, the QBus Master Module samples the MPC860 termination signals on the
rising edge of QCLK.
The MC68360 termination inputs to the QBus Master Module can be skewed by as
much as one clock period. However, they must meet the required setup and hold time
required with respect to the falling edge of QCLK. HALT_/TRETRY_ is ignored if
asserted alone. In a Normal and Halt condition, the QBus Master Module delays the
termination until HALT_/TRETRY_ is negated. This feature of the MC68360 allows
software to verify the internal state of the MC68360 during an error. During MC68360
Retry terminations the QBus master negates BB_/BGACK_, and will re-request the bus
(assert BR_) when HALT_/TRETRY_ is negated.
Chapter 4: The PCI Target Channel
QSpan II User Manual 79
May 16, 2013
4.8.3 MPC860 Cycle Terminations
When MPC860 transfers are completed, BB_/BGACK_ is negated by the QBus Master
Module on the rising clock edge and tristate d on the next falling clock edge to terminate
the transaction currently in progress (see Table 28).
4.8.4 M68040 Cycle Terminations
When M68040 transfers are completed, BB_/BGACK_ is negated by the QBus Master
Module on the rising clock edge and tristated on the next falling clock edge (see
Table 29).
Table 27: MC68360 Cycle Terminations of QBus Master Module
Termination
Type
DSACK0_, DSACK1_/TA_ BERR_/TEA_ HALT_/TRETRY_
t0t1t0t1t0t1
Normal Asserted Asserted Negated Negated Negated Don’t Care
Normal & HaltaAsserted Asserted Negated Negated Asserted Asserted
Bus Error Don’t Care
Don’t Care Don’t Care
Don’t Care Asserted
Negated Asserted
Asserted Negated
Negated Negated
Negated
Retry Don’t Care
Don’t Care Don’t Care
Don’t Care Asserted
Negated Asserted
Asserted Don’t Care
Don’t Care Asserted
Asserted
t0: First sample on falling edge of QCLK t1: Second sample on falling edge of QCLK
a. QSpan II as QBus master will sample DSACK x 2 QCLK rising edges after HALT negation.
Table 28: MPC860 Cycle Terminations of QBus Master Module
Termination Type DSACK1_/TA_ BERR_/TEA_ HALT_/TRETRY_
Normal Asserted Negated Don’t Care
Bus Error Don’t Care Asserted Don’t Care
Retry Negated Negated Asserted
Table 29: M68040 Cycle Terminations of QBus Master Module
Termination Type DSACK1_/TA_ BERR_/TEA_
Normal Asserted Negated
Bus Error Negated Asserted
Retry Asserted Asserted
Chapter 4: The PCI Target Channel
QSpan II User Manual80 May 16, 20 13
4.8.5 Terminations driven by the PCI Target Module
This section lists the terminations generated by the PCI Target Module, and summarizes
the conditions under which the various terminations are issued.
QSpan II PCI Target Module generates the following PCI terminations:
Target-Disconnect
Target-Retry
•Target-Abort
4.8.5.1 Target-Disconnect
During a Target-Disconnect, a termination is requested by the tar get because it is unable
to respond within the latency requirements of the PCI 2.2 Specification, or it requires a
new address phase. This termination is signaled when the target holds TRDY# and
STOP# asserted. Target-Disconnect means that the transaction is terminated after data is
transferred. Target-Disconnects can be issued by the QSpan II under the following
conditions:
A PCI master attempts to burst to a Target Image whose transfers are set to I/O
space. In this case, a target-disconnect is issued after the first data phase.
A PCI master attempts to burst to a Target Image with posted writes disabled and
the current data phase — processed as a delayed writehas completed on the
QBus (see “Acceptance of Burst Writes by the PCI Target Module” on page 72).
A PCI master has attempted a burst read and the QBus Master Module has
completed the single transfer.
A 128 byte boundary is reached.
The Px-FIFO fills during a burst write.
A burst transfer requiring non-linear burst address incrementing is attempted.
TRDY# is negated for eight PCLKs during a PCI burst read. This is optional (for
more information, see “PCI Target Prefetch Disconnect” on page 80).
PCI Target Prefetch Disconnect
QSpan II can be programmed to perform a Target-Disconnect while completing
prefetch reads in the PCI Target Channel. To enable this feature, set the PCI Target
Channel Prefetch Disconnect (PTC_PD) bit in the MISC_CTL2 register (see Table 130
on page 278).
A disconnect is issued if the TRDY# signal is negated for ei ght PCI clock cycles during
a target prefetch read transaction. A new prefetch is started on the QBus when the
master continues the disconnected read.
Under most conditions, the target is able to source or sink the data
requested by the master until the master terminates the transaction. But
when the target is unable to complete the request, it can use the STOP#
signal to initiate termination of the transaction.
Chapter 4: The PCI Target Channel
QSpan II User Manual 81
May 16, 2013
4.8.5.2 Target-Retry
During a Target-Retry, a termination is requested by the target because it cannot
currently process the transaction. This termination is communicated by the target
asserting STOP# while not asserting TRDY#. Target-Retry means that the transaction is
terminated after the address phase without any data transfer. The PCI Target Module
retries accesses under the following conditions:
An external PCI bus master attempts to post a single write or the first phase of a
burst write and the Px-FIFO does not have the number of data entries free that are
specified by the cacheline (CLINE[1:0] in the PCI_MISC0 register). This
Target-Retry only occurs if the PWEN bit is set to 1.
A delayed transaction is in progress in the PCI Target Channel.
A burst read is requested but the ensuing read has not terminated on the QBus.
A PCI bus master attempts a write through the PCI Target Channel while a read is
in progress (in either the QBus Slave Channel or the PCI Target Channel) and that
read has not completed on the read-destination bus (for example, the PCI bus or the
QBus, respectively) For more information, see “Reads and PCI Transaction
Ordering” on page 75.
4.8.5.3 Target-Abort
During a Target-Abort, a termination is issued by a target for a transaction which it can
not respond to, or during which a fatal error occurred. This is signaled by the target
asserting STOP# and negating DEVSEL#. Although there may be a fatal error for the
initiating application, the transaction completes gracefully, ensuring normal PCI
operation for other PCI resources.
Except during posted writes (see “Terminations of Posted Writes” on page 82), the
termination generated by the PCI Target Module is determined by the termination on
the QBus. For read transactions and delayed write transactions, the master is retried
until the QBus transaction is complete. Once the QBus transaction is complete, the PCI
bus master receives a translated version of the QBus termination.
The following table shows how QBus terminations are translated to the PCI bus in the
case of delayed transactions. As this table shows, the PCI Target Module generates a
Target-Abort when a delayed transfer results in a bus error on the QBus.
Chapter 4: The PCI Target Channel
QSpan II User Manual82 May 16, 20 13
4.8.6 Terminations of Posted Writes
PCI bus terminations of posted writes are not influenced by QBus terminations. If a
posted write leads to a bus error on the QBus, this termination is not signalled on the
PCI bus to the PCI bus master. However, errors on the QBus are accessible to PCI
Masters through error logging registers (if error logging is enabled by the EN bit of the
QB_ERRCS register). QBus errors can be configured as a source of interrupts.
If the EN bit in the QB_ERRCS register (see Table 147 on page 291) is set, then the
QSpan II records the address, transaction code, data, and size of a posted write
transaction that results in a bus error. In this case, an error is indicated by the ES bit of
the QB_ERRCS register. Transfers in the PCI Target Channel are suspended until the
ES bit is cleared. The QB_ERRCS register also records the TC and SIZ information of
the transaction error. The address of the transaction error is latched in the QB_AERR
register (see Table 148 on page 292). The data of the transaction error is latched in the
QB_DERR register (see Table 149 on page 293).
If error logging is enabled and the PCI Target Channel is errored, the Px-FIFO is frozen
until the ES bit in the QB_ERRCS register is cleared. Posted write operation continues
with the next enqueued posted write once the ES bit of the QB_ERRCS is cleared.
However, if error logging is not enabled and the PCI Target Channel is errored, the
errored transfer is lost and posted write operation continues with the next enqueued
transfer.
An interrupt is generated upon the logging of an error (ES bit in QB_ERRCS) only if
the QEL_EN bit in INT_CTL register is set (see Table 120 on page 263). If generated,
the interrupt is directed to the QBus or the PCI bus, depending on the QEL_DIR bit in
the INT_DIR register (see Table 121 on page 266). Interrupts are described in
Chapter 8: “The Interrupt Channel” on page 113.
Table 30: Translation of Cycle Terminationa from QBus to PCI Bus
QBus Termination Received PCI Bus Termination Issued
Normal Master-Completion
Bus Error Target-Abort
Retry None b
a. This table applies to read transactions and delayed write transactions.
b. This cycle is not translated. The PCI Target Module retries the PCI bus master during delayed
transactions until the QBus Master Module receives a normal termination or a bus error.
QSpan II User Manual 83
May 16, 2013
Chapter 5: The IDMA Channel
This chapter describes the QSpan II’s IDMA Channel. The following topics are
discussed:
“PCI Read Transac tions” on page 85
“PCI Write Transactions” on page 87
“TC[3:0] Encoding with MPC860 IDMA” on page 88
“IDMA Status Tracking” on page 89
“IDMA Errors, Resets, and Interrupts” on page 89
“IDMA Endian Issues” on page 91
5.1 Overview
QSpan II can operate as a QBus IDMA peripheral or a DMA master for data transfers
between the QBus and the PCI bus (see Figure 7). For transfers going to or from the PCI
bus, software can perform bulk data movement using the QSpan II’s IDMA or DMA
Channel. The IDMA Channel supports single-address and dual-address cycles, and
fast-termination.
IDT recommends using the DMA Channel instead of the IDMA Channel
because it supports higher rates of data transfer between the PCI bus and
the QBus.
Chapter 5: The IDMA Channel
QSpan II User Manual84 May 16, 20 13
Figure 7: IDMA Channel — Functional Diagram
The IDMA Channel contains a bi-directional 256-byte (64-entry deep) FIFO called
I-FIFO. IDMA transactions are initiated on the QBus. The IDMA Channel can only
access PCI Memory space — it cannot access I/O or Configuration space. The QBus
Slave Module accepts IDMA read and write transfers of 16 or 32 bits. The MPC860’s
IDMA must be programmed for level-sensitive mode with the QSpan II; edge-sensitive
mode is not supported.
When programmed to perform writes to the PCI bus, the QSpan II requests transfers
from the processors IDMA on the QBus. Once the processors IDMA is requested for
write data, it loads posted writes into the I-FIFO. When suf ficient data is available in the
I-FIFO, the QSpan II requests the PCI bus and begins bursting data to the PCI target.
This process continues until the number of transfers programmed in the QSpan II’s
IDMA/DMA Transfer Count register completes (see Table 111 on page 250).
When programmed to perform IDMA transfers from the PCI bus to the QBus, the
QSpan II reads data from a PCI tar get and load s the data into the I-FIFO. As the I-F IFO
fills, the QSpan II requests the processors IDMA to transfer data from the QSpan II to
the destination on the QBus. The processors IDMA then transfers data from the QSpan
II’s I-FIFO until the number of transfers programmed into the QSpan II's IDMA
registers completes, or the QSpan II signa l s to the processors IDMA that there is no
additional data in the I-FIFO.
PCI
Target
Module
PCI
Master
Module
QBus
Master
Module
QBus
Slave
Module
IDMA/DMA Channel
PCI
Interface QBus
Interface
PCI
Bus
I-FIFO (IDMA)
QBus
I-FIFO (DMA)
Chapter 5: The IDMA Channel
QSpan II User Manual 85
May 16, 2013
QSpan II can be programmed to operate as a QBus IDMA peripheral. Although the
QBus Master and Slave mode is determined at reset, this does not affect th e QBus Slav e
Module which dynamic ally accepts MC68360 (QUICC) or MPC860 (PowerQUICC)
IDMA cycles. The following list defines the IDMA Channel’s features:
The IDMA Mode (IMODE) bit of the IDMA/DMA_CS register (see Table 109 on
page 246) must be set to indicate whether or not the IDMA Channel functions as an
MC68360 or an MPC860 IDMA peripheral.
QSpan II only supports level-sensitive handshaking with the MPC860.
QSpan II supports single-address and dual-address IDMA transfers.
QSpan II determines the type of IDMA transfer by dete cting the state of the
CSPCI_ pin when the IDMA cycle begins.
If CSPCI_ is negated when AS_ (MC68360 applications) or TS_ (MPC860
applications) is asserted, then single-address mode is selected. CSPCI_ must be
detected asserted when the cycle begins in order to use dual-address IDMA transfer
mode. This requires that the address programmed in the MPC860’s or MC68360’s
buffer pointer register cause the QSpan’s CSPCI_ chip select to be activated.
QSpan II does not latch the address off the QBus during dual-address IDMA
transfers.
5.2 PCI Read Transactions
This section describes the operation and programming of the QSpan II to move data
from the PCI bus to the QBus using the processors IDMA. The IDMA registers within
the QSpan II need to be programmed for a read transaction as follows:
The direction of the transfer must be set for reads. To do this, set the IDMA
Direction (DIR) bit to 0 in the IDMA/DMA_CS register (see Table 109 on
page 246). The IDMA Channel can operate in one direction at a time.
The QBus Port 16 (PORT16) bit of the IDMA/DMA_CS register indicates whether
IDMA transfers will be 16 or 32-bit on the QBus (see Table 109 on page 246).
MC68360 users can indicate whether fast termination mode is to be used for
dual-address or single-address IDMA cycle (bits QTERM and STERM in the
IDMA/DMA_CS register; see Table 109 on page 246).
The Programmable I-FIFO Watermark (IWM) field controls the burst read length
on the PCI bus if it is set to a non-zero value (see Table 113 on page 252). If IWM
equals 0, then the QSpan II PCI burst read length equals the CLINE setting (see
Table 113 on page 252).
The CLINE[1:0] field of the PCI_MISC0 register (see Table 72 on page 205)
determines how much data is read by the PCI Master Module (either four or eight
32-bit transfers within a burst read if the IWM is set to zero).
The IDMA/DMA_PADD register contains the absolute PCI address for an IDMA
transaction (see Table 110 on page 249). This address is aligned to a 4-byte
boundary (A1 and A0 always equal 0). If an IDMA transfer is required to cross an
A24 boundary, it must be programmed as two sepa rate transactions.
Chapter 5: The IDMA Channel
QSpan II User Manual86 May 16, 20 13
The CMD bit in the IDMA/DMA_CS register determines whether the read
transactio n on PCI proceeds as a Memory Read Line transaction or a Memory Read
Multiple transaction (see Table 109 on page 246).
The IDMA/DMA_CNT register must be programmed to indicate the amount of
data to transfer (see Ta ble 111 on page 250).
Once all the relevant data is programmed into the IDMA register, the IDMA/DMA Go
(GO) bit in the IDMA/DMA_CS register must be set to 1 to initiate the IDMA transfer.
Any status bit (IRST, DONE, IPE, or IDE) affected by a previous transfer must be
cleared prior to or while the GO bit is set.
5.2.1 Data Path
The PCI Master Module performs burst reads on the PCI bus to fill the I-FIFO. When
data is available in the I-FIFO, the QSpan II asserts DREQ_ to request IDMA service.
The processor acknowledges with DACK_/SDACK_, at which point the QSpan II
drives the data onto the QBus. With a 16-bit QBus port, the QSpan II unpacks each
32-bit read data from the PCI into two 16-bit transfers on the QBus.
The IDMA/DMA_CNT register indicates the number of bytes to transfer in an IDMA
transaction (see Table 111 on page 250). QSpan II decreases the transfer count by four
with every 32-bit transfer on the PCI bus: the IDMA Channel on the PCI Interface only
transfers 32-bit data. The maximum amount of data that can be transferred within an
IDMA transaction is 16 Mbytes (for example, 222 32-bit transfers). QSpan II can
prefetch data up to the next cacheline boundary and discard the extra data.
When the IDMA/DMA_CNT expires, the QSpan II sets the IDMA/DMA Done Status
(DONE) bit in the IDMA/DMA_CS register. The MC68360 IDMA asserts the DONE_
signal when its transfer counter expires. If the MC68360 is programmed with a larger
transfer count than the QSpan II, the QSpan II will prematurely assert the DONE bit. If
this happens, the MC68360 must reprog ra m the QSpan II’s IDMA/DMA_CNT register
to complete the remainder of the transaction. If the MC68360 is programmed with a
smaller transfer count than the QSpan II, the MC68360 will assert the DONE_ signal
when its IDMA count reaches zero, causing the QSpan II to negate DREQ_. The
MC68360 will then have to assert the IDMA/DMA Reset Request (IRST_REQ) bit in
the IDMA/DMA_CS register to reset the QSpan II’s IDMA Channel.
During MPC860 IDMA transfers, the QSpan II ignores the DONE_ signal.
The MC68360’s IDMA count register and the QSpan II’s
IDMA/DMA_CNT register must be programmed with the same value.
Chapter 5: The IDMA Channel
QSpan II User Manual 87
May 16, 2013
5.3 PCI Wr ite Transactions
This section describes the operation and programming of the QSpan II to move data
from the QBus to the PCI bus using the MC68360 or MPC860 IDMA. IDMA registers
need to be programmed for a write transaction as follows:
The direction of the transfer must be set for writes (DIR bit in the IDMA/DMA_CS
register set to 1; see Table 109 on page 246). The IDMA Channel operates in one
direction at a time.
MC68360 users can indicate whether fast termination mode is used for
dual-address or single-address IDMA cycle (bits QTERM and STERM in the
IDMA/DMA_CS register; see Table 109 on page 246).
The PORT16 bit of the IDMA/DMA_CS indicates whether IDMA transfers will be
16-bit or 32-bit on the QBus (see Table 109 on page 246).
The IWM field of the IDMA/DMA_CS register determines when the QSpan II will
begin to burst the data onto the PCI bus (Table 109 on page 246). Once the I-FIFO
contents equal IWM, the QSpan II burst writes up to the values of IWM - throttled
only by the PCI target. The IWM must not be programmed with a value greater
than the IDMA transfer byte count.
The CLINE[1:0] field of the PCI_MISC0 register determines the leng th of the burst
writes initiated by the PCI Master Module (see Table 72 on page 205). The burst
writes are either four or eight 32-bit transfers if the IWM bit is set to zero.
The IDMA/DMA_PADD register (see Table 110 on page 249) contai ns the
absolute PCI address for an IDMA transaction. This number is aligned to a 4-byte
boundary. An IDMA transfer wraps-around at the A24 bound ary. If an IDMA
transfer is required to cross an A24 boundary, it must be programmed as two
separate transactions. The IWM must not be programmed with a value greater than
the IDMA transfer byte count.
The IDMA/DMA_CNT register indicates the number of bytes to transfer in an
IDMA transaction (see Ta ble 111 on page 250).
The CMD bit in the IDMA/DMA_CS register determines whether the write
transaction on PCI proceeds as a Memory Write Invalidate or a Memory Write
transfer (see Table 109 on page 246).
Once all the relevant data is programmed in the IDMA register, the GO bit in the
IDMA/DMA_CS register must be set to 1 to initiate the IDMA transfer. Any status bit
(IRST, DONE, IPE, or IQE) affected by a previous transfer must be cleared prior to or
while the GO bit is set.
5.3.1 Data Path
QSpan II requests data from the IDMA by asserting DREQ_. By asserting
DACK_/SDACK_, the IDMA acknowledges that data is being written to the I-FIFO.
With a 16-bit QBus port, the QSpan II packs two 16-bit transfers from the QBus into
one 32-bit entry in the I-FIFO. When the I-FIFO is full the QSpan II negates DREQ_.
Chapter 5: The IDMA Channel
QSpan II User Manual88 May 16, 20 13
QSpan II requests the PCI bus when there is as much data in the I-FIFO as is specified
by the IWM field of the IDMA/DMA_CS register (if the IWM equals 0, the QSpan II
requests the PCI bus when a cacheline is queued in the I-FIFO). QSpan II burst writes
data to the PCI target.
The IDMA/DMA_CNT register indicates the number of bytes to transfer in an IDMA
transaction (see Table 111 on page 250). QSpan II decreases the transfer count by four
with every 32-bit transfer on the PCI bus; the IDMA Channel on the PCI Interface
transfers 32-bit data. The amount of data that can be transferred within an IDMA
transaction is 16 Mbytes (for example, 222 32-bit transfers).
When the IDMA/DMA_CNT expires, the QSpan II sets the DONE bit in the
IDMA/DMA_CS register. The MC68360 IDMA asserts the DONE_ signal when its
transfer counter expires. If the MC68360 is programmed with a larger transfer count
than the QSpan II, the QSpan II will prematur ely assert the DONE bit. This will require
the MC68360 to reprogram the QSpan II’s IDMA/DMA_CNT register in order to
complete the remainder of the transaction. If the MC68360 is programmed with a
smaller transfer count than the QSpan II, the MC68360 will assert the DONE_ signal
when its IDMA count reached zero, causing the QSpan II to negate DREQ_. The
MC68360 must then assert the IRST_REQ bit in the IDMA/DMA_CS register to reset
the QSpan II’s IDMA Channel.
During MPC860 IDMA transfers, the QSpan II ignores the DONE_ signal.
5.4 TC[3:0] Encoding with MPC860 IDMA
If the MPC860’s I/O Port pins are being shared between multiple functions (for
example, IDMA and Ethernet) then the TC[3:0] decoding must be implemen ted. This
allows peripheral devices (QSpan II or Ethernet devices) to determine when they are
involved in a transaction.
QSpan II’s TC[3:0] inputs can be used with SDACK_ to decode IDMA transactions.
The value that is decoded is programmed by the user through the TC[3:0] field in the
IDMA/DMA_CS register. QSpan II will decode the TC[3:0] lines for IDMA
transactions if the TC Encoding Enable (TC_EN) bit in the IDMA/DMA_CS register is
set to 1. If the TC_EN bit is set and an IDMA transfer is attempted where the TC[3:0]
input does not match the TC[3:0] IDMA/DMA_CS field, the QSpan II will not accept
the IDMA transaction.
This manual adopts the convention that the most significant bit is always
the largest number. MPC860 designers must ensure tha t they connect
their pins accordingly. For example, pin A[31] on the QSpan II connects
to pin A[31] on the MC68360 bus, but connects to pin A[0] on the
MPC860 bus. This applies to all MPC860 buses (D[31:0], AT[3:0],
TSIZ[1:0]) not only the address bus.
Chapter 5: The IDMA Channel
QSpan II User Manual 89
May 16, 2013
5.5 IDMA Status Tracking
The following bits in the IDMA/DMA_CS register record the status of the transaction:
The IDMA/DMA Active Status (ACT) bit in the IDMA/DMA_CS is set by the
QSpan II to indicate that an IDMA transfer is in progress.
The IDMA/DMA Done Status (DONE) bit indicates that the IDMA transfer is
complete.
The IDMA/DMA PCI Bus Error Status (IPE) bit is asserted when an error is
signaled on the PCI bus during an IDMA transfer.
The IDMA/DMA QBus Error S tatus (IQE) bit is asserted when an error is signaled
on the QBus during an IDMA transfer.
The IDMA/DMA Reset Status (IRST) bit is asserted when the QSpan II has reset
the IDMA Channel.
For more information about errors and resets, see “IDMA Errors, Resets, and
Interrupts” on page 89.
5.6 IDMA Errors, Resets, and Interrupts
This section describes how the QSpan II responds to PCI bus errors and QBus errors
during IDMA reads and writes. This section also discusses IDMA resets and interrupts.
When there is an error on either bus during IDMA transfers, the QSpan II will assert an
IDMA error status bit. If the error is on the PCI bus, then the IPE bit in the
IDMA/DMA_CS register is set (see Table 109 on page 246). If the error is on the QBus,
then the IQE bit is set. How the transfer proceeds following the error depends on
whether the transfer is a read or a write, and on what bus the error occurred. Table 31
summarizes the sequence of events following bus errors for each of these four cases.
If a QBus bus error occurs during an IDMA write transfer, the QSpan II continues to
write data until the IWM level is reached. This is possible because the QSpan only
initiates PCI activity once the IWM value is queued in the I-FIFO. Once the IWM
amount is transferred, the QSpan responds to the bus error on the QBus as indicated in
the following table.
The assertion of IRST, IPE, IQE and DONE can be mapped to the interrupt pins on
either bus using the QSpan II’s Interrupt Control Register (bits IRST_EN, IPE_EN,
IQE_EN and DONE_EN, see Table 120 on page 263). The bus that is interrupted
depends on the Interrupt Direction Register INT_DIR (see Table 121 on page 266). The
status of the individual interrupt sources can be determined by reading the
corresponding status bit (see Table 42 on page 116 and Table 119 on page 260). To clear
the interrupt, the original interrupt source must be cleared. For example, to clear the
IDMA Reset Interrupt, the IRST bit in the IDMA/DMA_CS register must be cleared
(see Table 109 on page 246). The following table is extracted from Chapter 8: “The
Interrupt Channel” on page 113.
Chapter 5: The IDMA Channel
QSpan II User Manual90 May 16, 20 13
Table 31: QSpan II’s Response to IDMA Errors
PCI Bus
Transfer PCI Bus Error QBus Error
Read
Prefetching stops.
IPE is set in the IDMA/DMA_CS register. Then
the QSpan II negates DREQ_. If enabled, an
interrupt is generated on the PCI bus or the
QBus.
QSpan II negates DREQ_.
Transfers on QBus stop.
IQE is set in the IDMA/DMA_CS register.
If enabled, an interrupt is generated on the PCI
bus or the QBus.
Prefetching stops when the current IDMA PCI
transfer (if any) is complete.
Write
PCI writes from I-FIFO are halted.
IPE is set in the IDMA/DMA_CS register.
If enabled, an interrupt is generated on the PCI
bus or the QBus.
The QSpan II negates DREQ_.
QSpan II negates DREQ_.
IQE is set in the IDMA/DMA_CS register.
If enabled, an interrupt is generated on the PCI
bus or the QBus.
If a PCI transfer from the I-FIFO is in progress,
any complete CLINE of data in the I-FIFO is
transferred to the PCI target. (See the following
section)
Table 32: IDMA Interrupt Source, Enabling, Mapping, Status and Clear bits
Source
Source Bits
IDMA/DMA_CS
(Table 109 on
page 246)
Write 1 to clear
Enable Bits
INT_CTL
(Table 120 on
page 263)
Mapping Bits
INT_DIR (T able 121
on page 266)
Interrupt Status Bits
INT_STAT
(Table 1 19 on
page 260)
IDMA QBus
Error IQE in
IDMA/DMA_CS IQE_EN IQE_DIR IQE_IS
IDMA PCI Bus
Error IPE in
IDMA/DMA_CS IPE_EN IPE_DIR IPE_IS
IDMA Reset IRST in
IDMA/DMA_CS IRST_EN IRST_DIR IRST_IS
IDMA Done DONE in
IDMA/DMA_CS DONE_EN DONE_DIR DONE_IS
Chapter 5: The IDMA Channel
QSpan II User Manual 91
May 16, 2013
An IDMA transfer that is halted due to an IDMA error (IPE or IQE asserted), will not
resume once the error condition is cleared. The IDMA Channel needs to be reset by
setting the IRST_REQ bit of the IDMA/DMA_CS (see Table 109 on page 246 ) . The
IRST status bit is set when the QSpan II has reset the IDMA Channel. Then a new
IDMA transfer can be programmed (either from where the error happened or the
previous transfer can be attempted again). The QBus Slave Channel is not affected by
IDMA Channel errors.
The IDMA Channel can be reset by setting the IRST_REQ bit in the IDMA/DMA_CS
register, depending on the value of the ACT bit in the IDMA/DMA_CS register (see
Table 109 on page 246). If the ACT bit is 0, then setting IRST_REQ to 1 has no effect.
If the ACT bit is 1, then setting the IRST_REQ bit has the following effects:
1. QSpan II negates DREQ_, which halts transfers on the QBus.
2. If the QSpan II is writing IDMA data on the PCI bus, the QSpan II will terminate
the transfer by negating FRAME# at the next cacheline; if the QSpan II is reading
data, FRAME# is negated immediately.
3. QSpan II flushes the I-FIFO (after negating FRAME#).
4. The ACT bit in the IDMA/DMA_CS register is set to 0 while the IRST bit is set to
1 (see Table 109 on page 246). Note that the IDMA/DMA_PADD register, the
IDMA/DMA_CNT register and the rest of the IDMA/DMA_CS register are not
reset.
5. If enabled, an interrupt is generated on the QBus or the PCI bus (see Chapter 8:
“The Interrupt Channel” on page 113).
5.7 IDMA Endian Issues
The PCI bus and Motorola processors differ in the way they order and address bytes.
These differences are explained in Appendix A: “Registers” on page 193. This section
describes how the QSpan II translates cycles from the QBus to the PCI bus in the IDMA
Channel.
The PCI bus is always a Little-Endian environment. The QBus can be configured as
Little-Endian or Big-Endian, depending on the value of the QBus Byte Ordering
Control bit (QB_BOC) in the MISC_CTL register (see Table 127 on page 274). The
default mode for the QBus is Big-Endian. QSpan II translates byte-lane ordering when
the QBus is Big-Endian, while preserving the addressing of bytes. When the QBus is
Little-Endian (according to QB_BOC), the QSpan II preserves byte-lane ordering,
while translating the addressing of bytes. Note that the QB_BOC bit affects transactions
in all channels.
Table 33 describes mapping of 16-bit QBus transactions in Little-Endian mode. The
byte lane ordering is preserved in Little-Endian mode. During a read transaction, a full
32-bit PCI transaction is unpacked into two 16-bit QBus transfers. During a write
transaction, two 16-bit QBus transactions are packed into the I-FIFO for one PCI
transfer. The table also shows the order in which the 16-bit QBus cycles appear.
Chapter 5: The IDMA Channel
QSpan II User Manual92 May 16, 20 13
The following table describes map pin g of 16-bit QBus transactions in Big-Endian
mode. The addressing of bytes is preserved in Big-Endian mode. During a read
transaction, a full 32-bit PCI transaction is unpacked into two 16-bit QBus transfers.
During a write transaction, two 16-bit QBus transactions are packed into the I-FIFO for
one PCI transfer. The table also shows the order in which the 16-bit QBus cycles appear .
The following table describes mapping of 32-bit QBus transactions in Little-Endian
mode. The byte lane ordering is preserved in Little-Endian mode.
The following table describes map pin g of 32-bit QBus transactions in Big-Endian
mode. The addressing of bytes is preserved in Big-Endian mode.
Table 33: 16-Bit Little Endian IDMA Cycle Mapping
QBus PCI bus
QBus Timing SIZ[1:0] A[1:0] D[31:0] BE[3:0]# D[31:0]
First 16-bit transfer: 10 00 B3 B2 xx xx Full 32-bit PCI bus Transfer
Second 16-bit transfer: 10 10 B1 B0 xx xx 0000 B3 B2 B1 B0
Table 34: 16-Bit Big-Endian IDMA Cycle Mapping
QBus PCI bus
QBus Timing SIZ[1:0] A[1:0] D[31:0] BE[3:0]# D[31:0]
First 16-bit transfer: 10 00 B0 B1 xx xx Full 32-bit PCI bus Transfer
Second 16-bit transfer: 10 10 B2 B3 xx xx 0000 B3 B2 B1 B0
Table 35: 32-Bit Little-Endian IDMA Cycle Mapping
QBus PCI bus
SIZ[1:0] A[1:0] D[31:0] BE[3:0]# D[31:0]
00 00 B3 B2 B1 B0 0000 B3 B2 B1 B0
Table 36: 32-Bit Big-Endian IDMA Cycle Mapping
QBus PCI bus
SIZ[1:0] A[1:0] D[31:0] BE[3:0]# D[31:0]
00 00 B0 B1 B2 B3 0000 B3 B2 B1 B0
QSpan II User Manual 93
May 16, 2013
Chapter 6: The DMA Channel
This chapter examines the function of the QSpan II’s DMA Channel. The following
topics are discussed:
“DMA Registers” on page 95
“Direct Mode DMA Operation” on page 97
“Linked List Mode DMA Operation” on page 98
6.1 Overview
QSpan II has a DMA Channel for high performance data transfer between the PCI bus
and the QBus (see Figure 8). The DMA Channel functions similarly to the IDMA
Channel in that it uses the existing IDMA registers (and some additional registers), and
shares the 256-byte I-FIFO with the IDMA Channel. Because of the shared FIFO, the
QSpan II cannot use its IDMA and DMA Channels at the same time.
IDT recommends using the DMA Channel over the IDMA Channel
because it supports higher rates of data transfer between the PCI bus and
the QBus.
Chapter 6: The DMA Channel
QSpan II User Manual94 May 16, 20 13
Figure 8: DMA Channel — Functional Diagram
There are two modes of operation for the DMA Channel: Direct Mode and Linked List
Mode (also called Scatter/Gather mode). In Direct Mode, the DMA registers are
programmed directly by an external master. In Linked List Mode, the DMA registers
are loaded from PCI Bus memory or QBus memory by the QSpan II. This allows the
QSpan II to follow a list of buffer descriptors established by the local controller or the
system host.
A block of DMA register contents stored in memory is called a Command Packet. A
command packet can be linked to another command packet. When the DMA has
completed the operations described by one command packet, it automatically moves to
the next command packet in the Linked List of command packets. A command packet
cannot initiate an IDMA transfer; it can only initiate a DMA transfer.
PCI
Target
Module
PCI
Master
Module
QBus
Master
Module
QBus
Slave
Module
IDMA/DMA Channel
PCI
Interface QBus
Interface
PCI
Bus
I-FIFO (IDMA)
QBus
I-FIFO (DMA)
Chapter 6: The DMA Channel
QSpan II User Manual 95
May 16, 2013
6.2 DMA Registers
The DMA Channel uses the IDMA registers (starting at Register offset 400), as well as
three additional registers: DMA_QADD (see Table 112 on page 251), DMA_CS (see
Table 113 on page 252) and DMA_CPP (see Table 114 on page 255).
The PCI address for the DMA transfer resides in IDMA/DMA Address Register
(IDMA/DMA_PADD). The QBus address for the DMA transfer resides in DMA QBus
Address Register (DMA_QADD). The PCI and QBus addresses are aligned to a
four-byte boundary. If a DMA transfer is required to cross an A24 boundary, it must be
programmed as two separate transactions.
The IDMA/DMA T ransfer Count Register (IDMA/DMA_CNT) contain s the number of
bytes to be transferred during the DMA transfer (see Table 111 on page 250). The
minimum value for the transfer count is 16 bytes, and it must be a multiple of four
bytes.
The DMA Command Packet Pointer (DMA_CPP) points to a 16-byte aligned address
location. This location is in QBus memory or PCI bus memory that contains the
command packet to be loaded for Linked List DMA.
Some of the register bits in the IDMA/DMA Control and St atus (IDMA/DMA_CS)
register are used by the DMA Channel. The following bits are not used by the DMA
Channel because they are only used during IDMA transfers:
•IWM
•TC
•TC_EN
•IMODE
QTERM
STERM
•PORT16
The IDMA/DMA_CS register uses two additional bits to support a DMA transfer:
DMA, which indicates a DMA transfer is requested; and CHAIN, which indicates a
Linked List DMA transfer is requested. All other register bits have the same function in
a DMA transfer as in an IDMA transfer.
An additional register, DMA Control and Status Register (DMA_CS) defines other
fields to control the QBus transaction generated by the QSpan II during DMA transfers.
QSpan II generates DMA transfers on the QBus as an MC68360 (QUICC) master , as an
MPC860 (PowerQUICC) master, or as an M68040 master, depending on the QBus
Master mode selected at reset (MSTSLV field in MISC_CTL). The QBus m aster only
generates burst cycles as an MPC860 master. The Transaction Code (TC) field
determines the transaction code generated on the QBus during a DMA transfer. The
INVEND bit inverts the endian setting of the QB_BOC setting in MISC_CTL. The
QBus Destination Size (DSIZE) determines the destination port size of the external
QBus slave.
Chapter 6: The DMA Channel
QSpan II User Manual96 May 16, 20 13
The three fields described in the previous paragraph are similar to the fields of the same
name in PCI Target Image registers (PBTIx_CTL). The IWM field controls the burst
size on PCI. If the IWM is set to zero, the burst length stored in the CLINE field, which
is stored in the PCI_MISC0 register, is used. The maximum burst size on PCI during
DMA transfers is 128 bytes.
The QBus OFF (Q_OFF) timer, which is set in the DMA_CS register (see Table 113 on
page 252), limits the DMA Channel’s access to the QBus during DMA transfers. For
large DMA transfers, set this field to a non-zero value to allow the PCI Target Channel
regular access to the QSpan II’s QBus master. Depending on the value programmed in
the Q_OFF field, the DMA Channel will not request the QBus for the programmed
number of QBus clocks when the DMA transfer on the QBus crosses the following: any
256-byte addre ss boundary, or a 64-byte boundary, de pending on the setting of
Maximum DMA Burst Size on QBus (MDBS) bit in the DMA_CS register (see
Table 113 on page 252).
To temporarily stop a DMA transfer in order to free up PCI bus or QBus bandwidth, the
DMA Stop (STOP) bit in DMA_CS can be set (see Table 113 on page 252). The DMA
transfer is stopped once any active DMA transfers are completed. Once the DMA is
stopped on the PCI and QBus, the STOP_STAT bit is set in DMA_CS. To restart a
stopped DMA transfer, the STOP bit must be cleared by writing a zero to the STOP bit.
The DMA Channel restarts from where it stopped once the STOP bit is cleared and the
Q_OFF counter has expired; if this function is enabled.
The Command Packet Location (CP_LOC) field is used during Linked List mode
operation to determine if the command packets reside in QBus memory or PCI Bus
memory. All the command packets in a Linked List must reside in QBus memory or
PCI Bus memory, but not in both.
6.2.1 Burst Cycles
The BURST_4 field in DMA_CS enables the QSpan II to generate burst cycles with
four dataphases on the QBus. This allows the QSpan II to work with the UPM of the
MPC860. For DMA transfers that begin at an address that is not 16-byte aligned, the
QSpan II generates single QBus cycles until a 16-byte boundary is reached and then
performs burst cycles. For DMA write transfers to the QBus which end at an address
that is not 16-byte aligned, the QSpan II generates single write cycles to finish the
transfer. For DMA read transfers on the QBus which end at an address not 16-byte
aligned, the QSpan II generates a burst cycle to the next 16-byte boundary (for example,
prefetch data up to the next cacheline boundary), and dis cards the extra data.
The Burst Enable (BRSTEN) field in IDMA/DMA_CS disables QBus burst cycle s
during DMA transfers when the QSpan II is MPC860 master. This allows the QSpan II
to operate in systems where the MPC860 is used with local memory that does not
support bursting.
Chapter 6: The DMA Channel
QSpan II User Manual 97
May 16, 2013
6.2.2 DMA Cycles on QBus
QSpan II can limit the number of single reads and writes performed on the QBus to
service the DMA. QSpan II can complete a maximum of 16 single cycles or 16 burst
cycles. If the QBus OFF timer in the DMA_CS register is set, the OFF timer becomes
effective on every 64-byte boundary when completing single cycles on the QBus, and
on every 256-byte b oundary when complet ing bu rst cycl es (see Table 1 13 on page 252).
QSpan II can also limit the number of clocks a DMA burst cycle is active on the QBus.
If this option is set through the MDBS bit in the DMA_CS register, it forces the QSpan
II to perform four burst cycles (64 bytes) at a time on the QBus (see Table 113 on
page 252). This allows the PCI Tar get Channel or an external QBus master to access the
QBus with lower latency. In this case, the QBus OFF timer becomes effective on every
64-byte boundary.
6.3 Direct Mode DMA Operation
When operated in Direct Mode, the DMA is initiated by programming the QSpan II’s
registers. The following fields in the listed registers must be set to the appropriate
values:
IDMA/DMA_CS (see Table 109 on page 246): CMD, DMA, CHAIN, DIR
DMA_CS (see Table 113 on page 252): TC, DSIZE, INVEND, IWM, Q_OFF,
BURST_4, BRSTEN, MDBS
IDMA/DMA_PADD (see Table 110 on page 249): ADDR (PCI address)
DMA_QADD (see Table 112 on page 251): Q_ADDR (QBus address)
IDMA/DMA_CNT (see Table 111 on page 250): CNT (Transfer count)
Interrupts can be produced by enabling the appropriate bits in the INT_CTL and
INT_DIR registers. Interrupts can be generated to indicate the following:
the completion of the DMA
the occurrence of PCI bus or QBus errors
6.3.1 Initiating a Direct Mode Transfer
Once all relevant data is programmed, set the GO bit in the IDMA/DMA_CS register to
1 to initiate the direct mode DMA transfer (see Table 109 on page 246). Any status bit,
such as IRST, DONE, IPE or IQE, set by a previous transfer must be cleared prior to, or
when the GO bit is set.
The KEEP_BB bit in the MISC_CTL2 register (see Table 130 on
page 278) is not supported for DMA operation. As such, do not set this bit
when the QSpan II DMA channel is used with the PowerQUICC memory
controller (UPM).
Chapter 6: The DMA Channel
QSpan II User Manual98 May 16, 20 13
QSpan II initiates read transfers on the source bus to fill the I-FIFO. Once data is
available in the I-FIFO the destination bus master drains the data from the I-FIFO. The
IWM field in DMA_CS register determines the amount of data transferred on the PCI
bus for each DMA transaction initiated by the PCI Master Module.
The IDMA/DMA_CNT register indicates the number of bytes left to transfer in the
DMA transaction. QSpan II decreases this transfer counter by four for every 32-bit
transfer on the PCI bus. The maximum amount of data that can be transferred using the
DMA is 16 Mbytes.
6.3.2 Terminating a Direct Mode Transfer
The completion of the DMA is signaled by an interrupt or is determined by polling the
DONE bit in IDMA/DMA_CS. While the DMA transfer is active, the ACT bit in
IDMA/DMA_CS is set. Any writes to the IDMA/DMA registers when the DMA is
active are ignored, except for the IRST_REQ bit in IDMA/DMA_CS and the STOP bit
in DMA_CS.
The DMA transfer can be terminated by setting the IDMA/DMA Reset Request
(IRST_REQ) bit in the IDMA/DMA_CS register to 1. When the DMA transfer is
terminated with IRST_REQ, the IRST status bit is set in IDMA/DMA_CS once the
DMA Channel finishes any active transfer. An interrupt can also be generated by the
IRST status bit.
If a QBus or PCI error (Master-Abort or Target-Abort) is encountered during a DMA
transfer, the DMA transaction is termina t ed and the IQE or IPE status bits are set in
IDMA/DMA_CS.
6.4 Linked List Mode DMA Operation
Linked List mode allows the DMA Channel to transfer a series of non-contiguous
blocks of data without software intervention (see Figure 9 on page 99). Each entry in
the Linked List is described by a command packet containing data for the QSpan II’s
DMA registers. The data structure for each command packet is the same, and contains
the necessary information to program the DMA address and control registers. Each
command packet is a record of four 32-bit data elements, for a total of 16 bytes. The
command packets must be aligned to a 16-byte address boundary.
The fourth word of data in the command packet contains the next command packet
pointer (DMA_CPP). The least significant bit (NULL bit) of the fourth command
packet word contains control information for the Linked List processing.
The NULL bit indicates the termination of the entire Linked List. If the NULL bit is set
to 0, the DMA processes the next command packet pointed to by the command packet
pointer. If the NULL bit is set to 1, then this command packet is considered to be the
last command packet in the Linked List, and the DMA stops at the completion of the
transfer described by this command packet. The DONE bit in IDMA/DMA_CS is set
upon the completion of the final command packet.
Chapter 6: The DMA Channel
QSpan II User Manual 99
May 16, 2013
Figure 9: Linked List DMA Operation
The maximum data transfer size for a Linked List DMA is 1 Mbyte
because only CNT[19:2] bits are loaded from the command packet.
IDMA/DMA_PADD Register
DMA_QADD Register
DMA_CS
Register IDMA/DMA_CNT Register
DMA_CPP Register N
31 20 0
N = null bit
IDMA/DMA_PADD Register
DMA_QADD Register
DMA_CS
Register IDMA/DMA_CNT Register
DMA_CPP Register N
31 20 0
N = null bit
IDMA/DMA_PADD Register
DMA_QADD Register
DMA_CS
Register IDMA/DMA_CNT Register
DMA_CPP Register N
31 20 0
N = 1 for last command packet
First Command Packet
in Linked-List
Second Command Packet
in Linked List
Last Command Packet
in Linked List
Register information
copied to DMA Control
and Address Registers
Linked List Start
Address in
Command Packet
Pointer Register
Chapter 6: The DMA Channel
QSpan II User Manual100 May 16, 20 13
6.4.1 Initiating a Linked List Mode DMA Operation
To initiate a Linked List Mode DMA, the command packets described in the previous
section must be set up in QBus memory or PCI bus memory. The final command packet
must have the NULL bit set to 1. The following fields in the DMA_CS register (see
Table 113 on page 252) must be programmed to the appropriate values:
•IWM, Q_OFF
BURST_4
BRSTEN
•CP_LOC
•MDBS
•TC
•DSIZE
•INVEND
The DMA_CPP must be programmed to point to the first command packet. The
following fields in the IDMA/DMA_CS register (see Table 109 on page 246) must be
programmed to the appropriate values:
•CMD
•DMA
CHAIN
To enable an interrupt upon the completion of the Linked List DMA or due to PCI bus
or QBus errors, the appropriate bits must be set in the INT_CTL and INT_DIR
registers.
Once all relevant data is programmed, the GO bit in the IDMA/DMA_CS register must
be set to 1 to initiate the Linked List DMA transfer . Any status bit (IRST, DONE, IPE or
IQE) set by a previous transfer must be cleared prior to, or when the GO bit is set.
The Linked List DMA Channel ignores the setting of IDMA/DMA_PADD,
DMA_QADD and IDMA/DMA_CNT, when the DMA bit and CHAIN bit are set to 1
in IDMA/DMA_CS. It uses the DMA_CPP and CP_LOC to read the first command
packet from either QBus or PCI bus memory. If it reads the command packet s from the
QBus, it saves the setting of TC, DSIZE and INVEND fields in the DMA_CS register at
the start of the Linked List DMA, and uses these values on subsequent loading of the
command packets. The command packet may change the values of these fields in
DMA_CS for the DMA transfer initiated by that command packet.
The following registers are updated from the contents of the command packet:
IDMA/DMA_PADD[31:2]
DMA_QADD[31:2]
DMA_CS[31:20]
Chapter 6: The DMA Channel
QSpan II User Manual 101
May 16, 2013
IDMA/DMA_CNT[19:2]
DMA_CPP[31:4]
The DMA Channel then starts the DMA transfer described by the command packet.
Once the software has set the GO bit, the software can monitor Linked List DMA
completion by either waiting for the generation of an interrupt, or by polling for the
DONE status bit in IDMA/DMA_CS. To determine the current command packet being
executed, the software can read the DMA_CPP register to determine whether the
command packet previous to this is being executed. The software can also read the
IDMA/DMA_CNT register to determine the amount of data that is left to be transferred
in the current command packet.
If the Linked List is set up in a circular queue where each packet points to the next in
the list and the last points to the first, and the software wants the DMA Channel to skip
over some of the command packets the software can set the transfer count in the
command packet (bits [19:0] of the third element) to 0. When the DMA Channel reads a
command packet that has a transfer count of 0, it reads and processes the next command
packet.
If the CP_LOC is set to 1 when the Linked List DMA Channel reads the next
command packet from the QBus memory it reads it in a single 16-byte burst if
BRSTEN in DMA_CS is set to 1. Otherwise it takes four single reads to load the
command packet. If a QBus error is encountered while reading the command packet,
the Linked List DMA is terminated and the IQE status bit in IDMA/DMA_CS is set. If
a QBus or PCI bus error is encountered while a DMA transfer described by the
command packet is in progress, th e Linked Li st DMA is terminated and the appropriate
status bit (IQE or IPE) is set in the IDMA/DMA_CS register.
If the CP_LOC is set to 0, the DMA Channel reads the command packet from PCI
memory using a burst read cycle. If a PCI error is encountered during this read, the
Linked List DMA is terminated and the IPE status bit in IDMA/DMA_CS is set.
The command packet pointer register (DMA_CPP) points to the next
command packet, and not to the command packet that is being executed.
At the completion of the current command packet, the next command
packet is loaded and the sequence continues until a comman d packet with
the NULL bit set to 1 is loaded.
Chapter 6: The DMA Channel
QSpan II User Manual102 May 16, 20 13
6.4.2 Terminating a Linked List Mode DMA Operation
To terminate a Linked List DMA operation, set the IRST_REQ bit to 1. In this case, the
Linked List DMA is terminated and the IRST status bit is set in the IDMA/DMA_CS
register once the DMA Channel finishes any active transfers.
The STOP bit in DMA_CS can temporarily stop the Linked List DMA. This can be
used to free up PCI bus or QBus bandwidth for time-sensitive data transfers. Any
updates to the command packets can be completed before the STOP bit is cleared and
the Linked List DMA is resumed. The STOP_STAT bit in DMA_CS indicates when the
DMA Channel is stopped. At this point any updates to the command packets in memory
can be finished.
The ACT bit in IDMA/DMA_CS is still set when the DMA is
temporarily stopped. The ACT bit is cleared when the Linked List DMA
is completed, an IRST_REQ is generated, or a bus error on PCI bus or
QBus is encountered.
QSpan II User Manual 103
May 16, 2013
Chapter 7: The Register Channel
This chapter describes the QSpan II’s Register Channel. The following topics are
discussed:
“Register Access Fairness” on page 104
“Register Access from the PCI Bus” on page 105
“Register Access from the QBus” on page 107
“Register Access Synchronization” on page 111
“Mailbox Registers” on pa ge 112
7.1 Overview
QSpan II provides 4 Kbytes of QSpa n II Control and Status Registers (QCSRs). These
registers program PCI settings and the QSpan II’ s operating parameters (see Figure 10).
The QCSRs consist of two functional groups: the PCI Configuration Registers and the
QSpan II Device Specific Registers (see Figure 11 on page 105). QCSR space is
accessible from the PCI bus and the QBus.
Since QSpan II registers can be accessed from either the PCI bus or the QBus, an
internal arbitration occurs to indicate ownership. The access mechanisms for the
QCSRs, including the arbitratio n protocol, diff er depending on whether the registers are
accessed from the PCI bus or the QBus. An internal pointer selects which bus can
access the registers. Default ownership of the Register Channel is granted to the
QSpan II’s PCI Target Module. When ownership of the Register Channel is granted to
the QBus Slave Module, register accesses from the PCI bus are retried.
Chapter 7: The Register Channel
QSpan II User Manual104 May 16, 20 13
Figure 10: Register Channel — Functional Diagram
7.2 Register Access Fairness
QSpan II can be configured to make register access fairer by setting the Register Access
Control (REG_AC) bit in MISC_CTL2 (see Table 130 on page 278). If this bit is set,
the register access port is parked at the bus that completed the last register access. For
example, if there was a QBus register access, then the register access port defaults to the
QBus. Any additional QBus register access receives an immediate response while a PCI
register access gets retried first, and the n succe eds when the register access port
switches to the PCI bus.
If register access is performed mainly from the QBus, set the REG_AC bit in the
MISC_CTL2 register (see Table 130 on page 278).
PCI
Target
Module
PCI
Master
Module
QBus
Master
Module
QBus
Slave
Module
PCI
Interface QBus
Interface
PCI
Bus
Register Channel
QBus
Chapter 7: The Register Channel
QSpan II User Manual 105
May 16, 2013
7.3 Register Access from the PCI Bus
The QCSRs can be accessed through Configuration cycles or in Memory space (see the
following figure). These accesses are discussed in the following sections.
Default ownership of the Register Channel is granted to the PCI Target Module. If an
external master on the PCI bus attempts to access the registers of the QSpan II, and the
ownership has been granted to the QBus Slave Module, the transfer will be retried on
the PCI bus.
Figure 11 : QSpan II Control and Status Registers
Only the PCI Configuration registers are accessible through PCI Configuration Type 0
cycles. PCI Configuration registers that reside in the lower 256 bytes of QCSR space
are accessible in PCI Configuration space. QSpan II’s PCI interface decode s AD[7:2]
for accesses to its PCI Configuration registers. IDSEL must be asserted for Type 0
Configuration access. Configuration access from the QBus is discussed in “PCI
Configuration Cycles Generated from the QBus” on page 108.
Chapter 7: The Register Channel
QSpan II User Manual106 May 16, 20 13
QSpan II registers can be accessed in Memory space but not in I/O space. To access
QCSRs from PCI bus Memory space, it is necessary to set the Memory Space bit in the
PCI_CS register to 1 (see Table 70 on page 201). This step is required for any PCI
Target Module access, including register accesses. The PCI_BSM SPACE bit is fixed at
0 so that registers can be accessed in PCI Memory space. The BA[31:12] field of the
PCI_BSM register specifies the base address in memory space of the QCSRs. The
QCSRs are located in Memory space as address offsets of this base address (see
Figure 11).
There is a direct mapping between values on the AD[1 1:0] lines and the register offsets.
The following table illustrates PCI Memory cycle access to bits 15-08 of the
PCI_CLASS register (see Table 71 on page 204). This table shows the AD[11:0] and
C/BE#[3:0] signals required to access byte 1. This table also shows how the data is
presented to the PCI master.
In systems where the QSpan II is on an add-in card, the MPC860 is the QBus Host. An
external host will read QSpan II’s PCI Configuration registers to program the
QSpan II’s PCI registers (for example, Base Address Registers). In this case, the
QSpan II’s Configuration registers can be programmed by reading from an external
EEPROM. When the QSpan II loads the registers from EEPROM, all PCI access to
QSpan II are retried.
A power-up option pin called PCI Access Disabled (PCI_DIS), sets a bit in the
MISC_CTL2 register to retry all access to the QSpan II from external PCI Masters. PCI
accesses to the QSpan II are retried until the QBus Host programs the QSpan II registers
and clears this bit. The host can then read the Configuration registers and program the
remaining QSpan II’s PCI registers.
Even if an EEPROM is used on the board, the QBus Host can still change certain
registers before the PCI host can access the QSpan II registers. In this case, the
PCI_DIS bit can also be loaded from EEPROM, and the QBus Host can clear it after it
modifies the QSpan II registers.
The PCI_DIS pin allows the QBus Host to initialize the QSpan II before the QSpan II
will respond to PCI configuration accesses. The serial EEPROM is no longer the only
method available to initialize the QSpan II.
Table 37: PCI Memory Cycle Access to bits 15-08 of the PCI_CLASS register
AD[11:0] (register offset) BE[3:0]# AD[31:0]a
a. Data phase.
0x008 1101 xx xx B1 xx
Chapter 7: The Register Channel
QSpan II User Manual 107
May 16, 2013
7.4 Register Access from the QBus
QSpan II’s registers can be selected by an external master from the QBus with the
CSREG_ chip-select pin. Since the QSpan II registers span 4K, only the lower 12 bits of
the QBus address are used (see Figure 12). Register accesses of 8-bit, 16-bit, or 32-bit
size can be preformed. However, the QSpan II is a 32-bit slave device (for more
information, see Table 8 on page 45 and Table 9 on page 46).
If an external master on the QBus attempts to access the QSpan II’s registers, the
transfer is retried on the QBus. QSpan II will then make an internal request for register
ownership by the QBus. The request is removed if no register access is attempted within
210 QCLK clock cycles. The request is also removed if a register access complete s on
the QBus without a subsequent register access beginning within 32 QCLK clock cycles
of the completion of the previous register access. This type of access is implemented
when the Register Access Control (REG_AC) bit is set to 0 in the MISC_CTL2 register
(see Table 130 on page 278).
Figur e 12: QC SR Access from the QBus
QSpan II’s registers do not support burst accesses. If a burst to register
space is attempted from the QBus, a bus error is issued.
PCI CONFIGURATION
SPACE
(PCICS)
QSPAN DEVICE
SPECIFIC REGISTERS 4 Kbytes
of QCSR
QBus Memory
Implicit QBus
base address
Chapter 7: The Register Channel
QSpan II User Manual108 May 16, 20 13
7.4.1 Examples of QBus Register Accesses
The following table illustrates Big-Endian access to bits 15-08 of the PCI_CLASS
register. This table shows the address and size signals required to access this byte. This
table also shows how the data is presented to the QBus master.
The following table illustrates Little-Endian access to bits 15-08 of the PCI_CLASS
register. There is no real difference between Big-Endian and Little-Endian access to the
QSpan II’s register. The only difference between Tables 38 and 39 is the name (not the
location) of the byte along the data lines.
7.4.2 PCI Configuration Cycles Generated from the QBus
PCI Configuration cycles of Type 0 or Type 1 can be initiated from the QBus. To initiate
Configuration cy cles complete the following:
1. Write the Target PCI address in the Configuration Address Register (see Table 115
on page 256).
This step determines how the address of the Configuration cycle is generated on the
PCI bus.
2. Access the Configuration Data register (see Table 117 on page 258). A read access
generates a Configuration read on the PCI bus; a write access generates a
Configuration write on the PCI bus.
This step causes the Configuration cycle to occur on the PCI bus. The following
subsections describe these two aspects of Config uration cycles.
Table 38: Big-Endian QBus Access to bits 15-08 of the PCI_CLASS register
A[11:0] SIZ[1:0] A[1:0]a
a. This is a subset of A[11:0].
D[31:0]
0x00A 01 10 xx xx B2 xx
Table 39: Little-Endian QBus Access to bits 15–08 of the PCI_CLASS r eg ister
A[11:0] SIZ[1:0] A[1:0]a
a. This is a subset of A[11:0].
D[31:0]
0x00A 01 10 xx xx B1 xx
The Bus Master (BM) bit in the PCI_CS register must be set before
attempting a PCI configuration cycle (see Table 70 on page 201).
Chapter 7: The Register Channel
QSpan II User Manual 109
May 16, 2013
7.4.3 Address Phase of PCI Configuration Cycles
The type of Configuration cycle that is generated on the PCI bus — Type 0 or T ype 1 —
is determined by the TYPE bit of the CON_ADD register (see Table 115 on page 256).
This determines how the address of the Configuration cycle is generated on the PCI bus.
When the QSpan II is being used as a host bridge, the MA_BE_D bit in the MISC_CTL
register must be set to a 1. If you set this bit to 1, it allows the QSpan II to signal a
successful Configuration cycle to the host processor, even if a Master-Abort occurs on
the PCI bus.
If the TYPE bit is set to 1, an access of the CON_DATA register from the QBus
interface performs a corresponding Configuration Type 1 cycle on the PCI bus (see
Table 1 17 on page 258). During the address phase of the Configuration Type 1 cycle on
the PCI bus, the PCI address lines carry the values encoded in the CON_ADD register
(AD[31:0] = CON_ADDR[31:0]).
If the TYPE bit set to 0, an access of the CON_DATA register from the QBus interface
performs a corresponding Configuration Type 0 cycle on the PCI bus. If the Device
Number is programmed it causes one of the upper address lines, AD[31:16], to be
asserted during the address phase of the Configuration Type 0 cycle; the other lines are
negated. (Table 40 shows which PCI address line is asserted as a function of the
DEV_NUM[3:0] field.) The remaining address lines during the address phase of the
Configuration cycle are controlled by the Function Number and Register Number fields
of the CON_ADD register:
AD[15:11] = 00000
AD[10:8] = FUNC_NUM[2 :0]
AD[7:2] = REG_NUM[5:0]
AD[1:0] = 00
Chapter 7: The Register Channel
QSpan II User Manual110 May 16, 20 13
7.4.3.1 Data Phase of PCI Configuration Cycles
PCI Configuration accesses from the QBus proceed as delayed transactions. This is true
for Configuration reads as well as writes. When the CON_DATA register is accessed,
the QBus master is retried. QSpan II then initiates a Configuration cycle on the PCI bus.
The PCI byte enable driver is dependent on the attributes of the QBus cycle (for
example, QBus address and SIZ signals) during the Configuration cycle. Until the
Configuration cycle completes on the PCI bus any further Configuration cycle attempt
is retried. In the case of a read (read to CON_DATA), the data from the PCI bus is
stored in the CON_DATA register. After the Configuration cycle completes on the PCI
bus — when the QBus master attempts to access the CON_DATA register at the same
address — the cycle completes successfully on the QBus. In the case of a write (write to
CON_DATA), the cycle completes on the QBus after the Configuration write completes
on the PCI bus.
7.4.4 Interrupt Acknowledge Cycle
A mechanism is provided for a QBus register read to generate a PCI Interrupt
Acknowledge cycle (see “Interrupt Acknowledge Cycle” on page 119.)
Table 40: PCI AD[31:16] lines ass erted as a function of DEV_NUM field
DEV_NUM[3:0] AD[31:16]
0000 0000 0000 0000 0001
0001 0000 0000 0000 0010
0010 0000 0000 0000 0100
0011 0000 0000 0000 1000
0100 0000 0000 0001 0000
0101 0000 0000 0010 0000
0110 0000 0000 0100 0000
0111 0000 0000 1000 0000
1000 0000 0001 0000 0000
1001 0000 0010 0000 0000
1010 0000 0100 0000 0000
1011 0000 1000 0000 0000
1100 0001 0000 0000 0000
1101 0010 0000 0000 0000
1110 0100 0000 0000 0000
1111 1000 0000 0000 0000
Chapter 7: The Register Channel
QSpan II User Manual 111
May 16, 2013
7.5 Register Access Synchronization
QSpan II supports non-simultaneous access to its registers from the QBus Interface and
the PCI Interface. This feature presents a synchronization issue. QSpan II does not have
the ability to lock out register accesses from one interface so that accesses can be
performed on the other interface. QSpan II also does not have semaphore capabilities. If
a master on one interface is executing a test and set procedure — reading from a register
and then setting part or all of the register — there is the possibility that between the test
and the set, a master on the other interface sets the same register. This issue is most
relevant to the Interrupt Contro l register (see Table 120 on page 263).
Figure 13: Example of a Register-Access Synchronization Problem
Two possible solutions to this problem include the following:
1. Perform byte-wide writes on the PCI bus as opposed to 32-bit writes. This does not
solve all the register-access synchronization problems because the other 7 bits in
the write may change between a read and a write. Since the SI1 bit and the
DONE_EN bit (see Table 120 on page 263) are separated by two bytes, it would
solve the problem described in Figure 13.
2. Design the system to always set the DONE_EN bit, or whatever other bit is
susceptible to this problem. However, this may lead to the generation of more
interrupts, and consequently, an impact on performance.
PCI Master QBus Processor
1. PCI master reads entire INT_CTL register.
2. QBus processor writes to entire INT_CTL register (in
order to set the DONE_EN bit so that the QSpan II will
interrupt the QBus when the IDMA is finished with a
transaction).
3. PCI master performs a 32-bit write to the INT_CTL
register (in order to set the SI1 bit) and inadvertently
clears the DONE_EN bit (because it was clear in Step 1
above).
4. QSpan II does not generate an interrupt when the
IDMA transaction completes because the DONE_EN bit
is clear.
Chapter 7: The Register Channel
QSpan II User Manual112 May 16, 20 13
7.6 Mailbox Registers
QSpan II has four 32-bit mailbox registers which provide an additional communication
path between the PCI bus and the QBus. The mailboxes support read and write accesses
from either bus and can be enabled to generate an interrupt on either bus when they are
written to from the other bus.
For example, if mailbox 0 is programmed to generate a QBus interrupt — by setting
MB0_EN to 1 in INT_CTL register, and MB0_DIR to 0 in INT_DIR register — then a
PCI write with any of the byte-lanes enabled to mailbox 0 will generate a QBus
interrupt (QINT_). In this case, mailbox 0 can also be written to from the QBus, but this
will not generate a QBus interrupt. Likewise, if a mailbox is programmed to generate a
PCI interrupt, a PCI interrupt is only generated when that mailbox is written to from the
QBus.
To clear an interrupt, write a 1 to the corresponding status bit in INT_STAT (see
Table 119 on page 260).
QSpan II User Manual 113
May 16, 2013
Chapter 8: The Interrupt Channel
This chapter describes the function of the QSpan II Interrupt Channel. The following
topics are discussed:
“Hardware-Triggered Interrupts” on page 114
“Software-Triggered Interrupts” on page 115
“Interrupt Acknowledge Cycle” on page 119
“Disabling PCI Interrupts” on page 11 9
8.1 Overview
Certain hardware and software events can trigger interrupts on the QBus and the PCI
bus through the Interrupt Channel (see Figure 14). Two bidirectional interrupt pins are
provided: INT# for the PCI bus; QINT_ for the QBus.
Chapter 8: The Interrupt Channel
QSpan II User Manual114 May 16, 20 13
8.2 Hardwar e-Triggered Interrupts
In order for an input to trigger an interrupt on the opposite interface, the corresponding
enable bit must be set in the INT_CTL register (see Table 120 on page 263 ) . For
example, for INT# to trigger QINT_, the INT_EN bit must be set. The status of the
interrupt is logged in the INT_STAT register.
Figur e 14 : Inter rupt Channel — Functi onal Dia gram
It is only possible to route interrupts in one direction at a time. For
example, it is not possible to allow PCI interrupt sources to be mapped to
QINT_ while allowing QINT_ sources to be mapped to INT#.
PCI
Target
Module
PCI
Master
Module
QBus
Master
Module
QBus
Slave
Module
PCI
Interface QBus
Interface
PCI
Bus
Interrupt Channel
Register Channel
QBus
Chapter 8: The Interrupt Channel
QSpan II User Manual 115
May 16, 2013
If INT_EN is set, then the assertion of INT# causes QINT_ to be asserted until INT# is
negated and the INT_IS bit is cleared. Because INT# is level sensitive, if the INT_IS bit
is cleared before INT# is negated, the clearing of the bit will have no af fect and QINT_
will remain asserted.
To negate QINT_ when its assertion is caused by the assertion of PERR# or SERR#,
complete the following procedure:
1. Clear the error status bit in the source PCI device.
2. Clear the status bit in the INT_STAT register.
To negate INT# when its assertion is caused by the assertion of QINT_, negate QINT_
and then clear the QINT_IS bit in the INT_STAT register.
8.3 Software-Triggered Interrupts
QSpan II can generate interrupts based upon internal events provided that the interrupt
source is enabled in the INT_CTL register (see Table 120 on page 263). Interrupts can
be mapped to an interrupt output pin on the PCI bus (INT#) or the QBus (QINT_)
depending on the value of the interrupt mapping bit in the INT_DIR register (see
Table 121 on page 266). The status of the individual interrupt sources can be
determined by reading the corresponding status bit (see Table 119 on page 260). To
clear an interrupt, the original interrupt source must be cleared first. For example, to
clear the IDMA Reset Interrupt, the IRST bit in the IDMA/DMA_CS register must be
cleared first (see Table 109 on page 246).
Table 41: Mapping of Hardware-Initiated Interrupts
Input
Enable bits
(INT_CTL, see T able 120
on page 263)
Status Bits
(INT_STAT, see
Table 119 on page 260) Output
INT# INT_EN INT_IS QINT_
PERR# PERR_EN PERR_IS
SERR# SERR_EN SERR_IS
QINT_ QINT_EN QINT_IS INT#
Chapter 8: The Interrupt Channel
QSpan II User Manual116 May 16, 20 13
Table 42: Interrupt Source, Enabling, Mapping, Status and Clear bits
Source Source Bits
Write 1 to clear
Enable Bits
INT_CTL (see T able 120
on page 263)
Mapping Bits
INT_DIR (see Table 121
on page 266)
Interrupt S t atus Bits
INT_ST AT (see T able 1 19
on page 260)
QBus Slave Channel Errors (Error on the PCI bus)
PCI Bus Error ES in PB_ERRCS
(see Table 97 on
page 232)
PEL_EN PEL_DIR PEL_IS
Data Parity Error MD_PED in PCI_CS
(see Table 70 on
page 201)
MDPED_EN MDPED_DIR MDPED_IS
PCI Bus Target Channel Errors (Error on the QBus)
QBus Error ES in QB_ERRCS
(see Table 147 on
page 291)
QEL_EN QEL_DIR QEL_IS
IDMA/DMA C h annel Eventsa
IDMA/DMA
QBus Error IQE in IDMA/DMA_CS
(see Table 109 on
page 246)
IQE_EN IQE_DIR IQE_IS
IDMA/DMA
PCI Bus Error IPE in IDMA/DMA_CS
(see Table 109 on
page 246)
IPE_EN IPE_DIR IPE_IS
IDMA/DMA
Reset IRST in IDMA/DMA_CS
(see Table 109 on
page 246)
IRST_EN IRST_DIR IRST_IS
IDMA/DMA
Done DONE in
IDMA/DMA_CS
(see Table 109 on
page 246)
DONE_EN DONE_DIR DONE_IS
PCI Bus Error ES in PB_ERRCS
(see Table 97 on
page 232)
PEL_EN PEL_DIR PEL_IS
Miscellaneous Events
PCI_CS Register
Interrupt Status Status bit(s) in Table 70
on page 201bPCSR_EN PCSR_DIR PCSR_IS
MailBox 3
Interrupt Status - MB3_EN MB3_DIR MB3_IS
MailBox 2
Interrupt Status - MB2_EN MB2_DIR MB2_IS
MailBox 1
Interrupt Status - MB1_EN MB1_DIR MB1_IS
MailBox 0
Interrupt Status - MB0_EN MB0_DIR MB0_IS
QBus Data
Parity Error - QDPE_EN QDPE_DIR QDPE_S
Chapter 8: The Interrupt Channel
QSpan II User Manual 117
May 16, 2013
Power State
Changed Interrupt
Status
PME_EN PCI_PMCS
(see Table 85 on
page 218)
PSC_EN PSC_DIR PSC_S
Outbound
Post_List Not
Empty Status
- OPNE_EN OPNE_DIR OPNE_S
Inbound Post_List
New Entry
Interrupt Status
- IPN_EN IPN_DIR IPN_S
Inbound Free_List
Empty Status - IFE_EN IFE_DIR IFE_S
Outbound
Free_List Empty
Status
- OFE_EN OFE_DIR OFE_S
Inbound Post_List
Full Status - IPF_EN IPF_DIR IPF_S
Outbound
Free_List Full
Status
- OFF_EN OFF_DIR OFF_S
a. See also “IDMA Errors, Resets, and Interrupts” on page 89.
b. Any of the following bits in PCI_CS: D_PE, S_SERR, R_MA, R_TA, or S_TA.
Table 42: Interrupt Source, Enabling, Mapping, Status and Clear bits (Continued)
Source Source Bits
Write 1 to clear
Enable Bits
INT_CTL (see T able 120
on page 263)
Mapping Bits
INT_DIR (see Table 121
on page 266)
Interrupt S t atus Bits
INT_ST AT (see T able 1 19
on page 260)
Chapter 8: The Interrupt Channel
QSpan II User Manual118 May 16, 20 13
Four software interrupt bits are provided: Software Interrupt 0 through 3. Setting a
software interrupt bit (SI3, SI2, SI1, or SI0) triggers the interrupt status (see the
following table) and causes the QSpan II to generate an interrupt on the QBus (QINT_)
or PCI bus (INT#), depending on the relevant mapping bit. There is no enable bit for
software interrupts. The interrupt line will be driven until the status bit is cleared. To
clear the status bit wri te a 1.
8.3.1 Interrupt Generation due to PCI Configuration Register Status Bits
QSpan II can generate an interrupt (QINT_ or INT#) when any of the status bits in the
PCI_CS register is set.
The direction of the interrupt is controlled by the PCSR_DIR bit in the INT_DIR
register (see Table 121 on page 266). QSpan II generates the interrupt and sets the
PCSR_IS bit in the INT_STAT register when any of the following status bits is set (see
Table 119 on page 260):
•D_PE
S_SERR
•R_MA
•R_TA
•S_TA
excluding MD_PED
Ta ble 43: Software Interrupt Mapping, Status and Sou rce bits
Source
Source Bits Mapping Bits Interrupt Status Bitsa
a. Wr ite 1 to clear the interrupt.
(INT_CTL, see
Table 120 on page 263) (INT_DIR, see T able 121
on page 266) (INT_STAT,
see Table 119 on page 260)
(INT_CTL2, see
Table 122 on page 269) --
Software Interrupt 0 SI0 SI0_DIR SI0_IS
Software Interrupt 1 SI1 SI1_DIR SI1_IS
Software Interrupt 2 SI2 SI2_DIR SI2_IS
Software Interrupt 3 SI3 SI3_DIR SI3_IS
Interrupts in one channel do not affect processing in the other channel.
Chapter 8: The Interrupt Channel
QSpan II User Manual 119
May 16, 2013
The MD_PED bit already generates an interrupt, so thi s functiona lity will not cause the
PCSR_EN status bit to be set. To clear the interrupt and interrupt status bit, write a 1 to
PCSR_IS in the INT_STAT (see Table 119 on page 260).
8.4 Interrupt Acknowledge Cycle
Reading the IACK_GEN register from the QBus causes an IACK cycle to be generated
on the PCI bus (see Table 118 on page 259). The byte lanes enabled on the PCI bus are
determined by SIZ[1:0] and A[1:0] of the QBus read. The address on the QBus used to
access the IACK_GEN registe r is passed directly over to the PCI bus during the PCI
IACK cycle. However, address information is ignored during PCI IACK cycles, so this
has no effect.
Reads from this register behave as delayed transfers: the QBus master is retried until the
read data is latched from the PCI Target. When the IACK cycle completes on the PCI
bus, the data is latched into the IACK_GEN register, which is returned as read data
when the QBus master attempts the cycle again.
W riti ng to this register from the QBus or PC I bus has no effect. Reads from the PCI bus
return all zeros.
8.5 Disabling PCI Interrupts
QSpan II is a single function device, so it implements a single PCI interrupt (INT#).
One restriction of this option is that it’s always enabled: INT_PIN is set to 1 in the
PCI_MISC1 register. If the system does not require the QSpan II to interrupt on the PCI
bus, the QSpan II can be disabled from requesting an interrupt on the PCI bus.
The Interrupt Pin (INT_PIN) field in PCI_MISC1 register can be loaded from
EEPROM, or programmed from the QBus side before the PCI BIOS can access this
register (see Table 83 on page 216). The INT_PIN setting does not affect the assertion
of the QSpan II’s INT# output. The INT_LINE field in PCI_MISC1 will still be R/W
(default=0). Software must set this field to 0xff to indicate “unknown” or “no
connection.” For more information see the PCI Local Bus Specification 2.2.
Chapter 8: The Interrupt Channel
QSpan II User Manual120 May 16, 20 13
QSpan II User Manual 121
May 16, 2013
Chapter 9: The EEPROM Channel
This chapter describes the QSpan II’s EEPROM Channel. The following topics are
discussed:
“EEPROM Configuration and Plug and Play Compatibility” on page 123
“EEPROM I2C Protocol” on page 123
“Mapping of EEPROM Bits to QSpan II Registers” on page 124
“Programming the EEPROM from the QBus or PCI Bus” on page 127
“EEPROM Access” on page 128
“Vital Product Data Support” on page 128
9.1 Overview
Some QSpan II registers can be programmed by data in an EEPROM at system reset
(for more information, see Table 44 on page 125). This allows board designers to
perform the following:
set identifiers for their cards on the PCI bus at reset
enable the PCI Bus Expansion ROM Control Registe r
set various address and parameters of image s
If the QSpan II is configured with EEPROM or by an external QBus
master using the PCI_DIS pin, the device can boot-up as a Plug and Play
compatible device (see “EEPROM Configuration and Plug and Play
Compatibility” on page 123).
Chapter 9: The EEPROM Channel
QSpan II User Manual122 May 16, 20 13
Figure 15: EEPROM Channel — Functional Diagram
QSpan II supports an additional scheme to be Plug and Play compatible without the use
of an EEPROM. In this case, the power-up option, PCI Access Disabled (PCI_DIS) is
pulled high during reset (see Table 130 on page 278). This forces the QSpan II to retry
all PCI access. During this time, the QBus Host can program the necessary registers —
for- example, the registers that are normally loaded from the EEPROM — and then
write a 0 to the PCI_DIS bit. This allows the QSpan II to accept PCI cycles.
QSpan II supports reads from and writes to the EEPROM.
256 bytes of data can be accessed with the EEPROM. QSpan II normally loads the first
12 bytes of data for its own programming. QSpan II can load the next 1 1 bytes from the
EEPROM if the last three bits of the 12th byte are 010.
The PCI_DIS option can also be enabled by loading from the EEPROM.
However , the EEPROM loadi ng cannot clear the PCI_DIS bit. Therefore,
if PCI_DIS is enabled from the EEPROM loading, then the Host must
configure the QSpan II’s registers before the QSpan II allows register
access from the PCI bus.
PCI
Target
Module
PCI
Master
Module
QBus
Master
Module
QBus
Slave
Module
PCI
Interface QBus
Interface
PCI
Bus
Register Channel
QBus
EEPROM
2
I C
Chapter 9: The EEPROM Channel
QSpan II User Manual 123
May 16, 2013
9.2 EEPROM Configuration and Plug and Play Compatibility
There are two ways to configure the EEPROM to allow the QSpan II to boot as a PCI
Plug and Play compatible device:
The EEPROM can be configured before it is placed on the board.
The EEPROM can be configured after it is installed. In this case, the first time the
QSpan II-based board boots, it will not be PCI Plug and Play compatible. You will
need to program the EEPROM from either the QBus or the PCI bus (see
“Programming the EEPROM from the QBus or PCI Bus” on page 127 for details).
The following sections discuss the implementation of the EEPROM.
9.3 EEPROM I2C Protocol
QSpan II supports the 2-wire I2C protocol, using a clock output (SCL) and a
I-directional signal (SDA). If the SDA or ENID pin is asserted as 1 during a PCI bus
reset (for example, RST# active), then at the conclusion of this reset the QSpan II reads
12 bytes of data from the EEPROM. QSpan II can also load the next 11 bytes from the
EEPROM if the last three bits of the 12th byte are 010b.
The read of the 12 bytes from the EEPROM is performed as a Sequential Read. After
the START condition the QSpan II puts out a 7-bit device select code of 1010000. The
four most significant bits of the device select code for the I2C protocol are required to
be 1010. The following three bits are chip-enable signals that are 000. The chip-enable
lines on the EEPROM must be tied low. QSpan II expects the data delivered from the
EEPROM starting at address zero. Figure 16 shows this Sequential Read transaction.
Figure 16: Sequential Read from EEPROM
After reset, the EEPROM port completes a STOP then a START before
loading from the EEPROM.
START
STOP
RW RW
START
DEV SEL BYTE ADDR DEV SEL BYTE 1
ACK ACK ACK ACK
...
BYTE 12
ACK NO ACK
...
Chapter 9: The EEPROM Channel
QSpan II User Manual124 May 16, 20 13
While the registers are being loaded from the EEPROM, all accesses to the QSpan II by
an external PCI bus master are terminated with a retry. During this period, write
accesses to the EEPROM programmable registers from the QBus have no effect, and
reads return all zeros.
9.4 Mapping of EEPROM Bits to QSpan II Registers
This section describes the mapping between EEPROM bits and the QSpan II’ s registers.
The following registers can be programmed by the EEPROM:
PCI Configuration (PCI_SID register): see Table 79 on page 212
PCI Expansion ROM (PCI_BSROM and PBROM_CTL registers): see Table 80 on
page 213 and Table 95 on page 230
PCI Bus Target Image 0 (PCI_BST0 and PBTI0_CTL registers): see Table 75 on
page 208 and Table 89 on page 222
PCI Bus Target Image 1 (PCI_BST1 and PBTI1_CTL registers): see Table 77 on
page 210 and Table 92 on page 226
QBus Slave Image 0 (QBSI0_CTL and QBSI0_AT registers): see Table 133 on
page 283 and Table 138 on page 285
PCI Configuration Space ID (PCI_ID register): see Table 69 on page 200
PCI Configuration Class (PCI_CLASS register): see Table 71 on page 204
PCI Configuration Miscellaneous 1 (PCI_MISC1 register): see Table 83 on
page 216
Miscellaneous Control 2 (MISC_CTL2 register): see Table 130 on page 278
PCI Power Management Capabilities (PCI_PMC register): see Table 84 on
page 217
Some EEPROM devices require a write control signal. This signal should
not be pulled inactive if the intention is to program the EEPROM device
with the QSpan II.
If RESETI_ is asserted when the QSpan II is reading from the EEPROM
then the EEPROM’s contents may not be loaded correctly.
Chapter 9: The EEPROM Channel
QSpan II User Manual 125
May 16, 2013
PCI Configuration Base Address for Tar get 0 (PCI_BST0 register): see T able 75 on
page 208
PCI Configuration Base Address for Tar get 0 (PCI_BST1 register): see T able 77 on
page 210
Table 44: Destination of EEPROM Bits Reada
Byte
Function
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0
PCI_SID
[31]
(SID) [30]
(SID) [29]
(SID) [28]
(SID) [27]
(SID) [26]
SID) [25]
(SID) [24]
(SID)
1
PCI_SID
[23]
(SID) [22]
(SID) [21]
(SID) [20]
(SID) [19]
(SID) [18]
(SID) [17]
(SID) [16]
(SID)
2
PCI_SID
[15]
(SVID) [14]
(SVID) [13]
(SVID) [12]
(SVID) [11]
(SVID) [10]
(SVID) [9]
(SVID) [8]
(SVID)
3
PCI_SID
[7]
(SVID) [6]
(SVID) [5]
(SVID) [4]
(SVID) [3]
(SVID) [2]
(SVID) [1]
(SVID) [0]
(SVID)
4
Enables PCI_
BSROMbPBROM_CTL
[22]
(BS) [21]
(BS) [20]
(BS) [19]
(TC) [18]
(TC) [17]
(TC) [16]
(TC)
5
PBROM_CTL
[15]
(TA) [14]
(TA) [13]
(TA) [12]
(TA) [11]
(TA) [10]
(TA) [9]
(TA) [8]
(TA)
6
PBROM_CTL
[7]
(TA) [6]
(TA) [5]
(TA) [4]
(TA) [3]
(TA) [2]
(TA) [1]
(TA) [0]
(TA)
7
PBROM_CTL Enables
PCI_BST0bPBTI0_CTL
[25]
DSIZE) [24]
(DSIZE) [27]
(BS) [26]
(BS) [25]
(BS) [24]
(BS) [6]
(PAS)
8
Enables
PCI_BST1bPBTI1_CTL QBSI0_CTL
[27]
(BS) [26]
(BS) [25]
(BS) [24]
(BS) [6]
(PAS) [31] (PWEN) [24]
(PAS)
9
QBSI0_AT
[31]
(TA) [30]
(TA) [29]
(TA) [28]
(TA) [27]
(TA) [26]
(TA) [25]
(TA) [24]
(TA)
Chapter 9: The EEPROM Channel
QSpan II User Manual126 May 16, 20 13
10
QBSI0_AT
[23]
(TA) [22]
(TA) [21]
(TA) [20]
(TA) [19]
(TA) [18]
(TA) [17]
(TA) [16]
(TA)
11
QBSI0_AT Enable
long EEPROM loadc
[7]
(BS) [6]
(BS) [5]
(BS) [4]
(BS) [1]
(EN)
12
PCI_ID
[15]
(DID) [14]
(DID) [13]
(DID) [12]
(DID) [11]
(DID) [10]
(DID) [9]
(DID) [8]
(DID)
13
PCI_ID
[7]
(DID) [6]
(DID) [5]
(DID) [4]
(DID) [3]
(DID) [2]
(DID) [1]
(DID) [0]
(DID)
14
PCI_ID
[15]
(VID) [14]
(VID) [13]
(VID) [12]
(VID) [11]
(VID) [10]
(VID) [9]
(VID) [8]
(VID)
15
PCI_ID
[7]
(VID) [6]
(VID) [5]
(VID) [4]
(VID) [3]
(VID) [2]
(VID) [1]
(VID) [0]
(VID)
16
PCI_CLASS
[7]
(BASE) [6]
(BASE) [5]
(BASE) [4]
(BASE) [3]
(BASE) [2]
(BASE) [1]
(BASE) [0]
(BASE)
17
PCI_CLASS
[7]
(SUB) [6]
(SUB) [5]
(SUB) [4]
(SUB) [3]
(SUB) [2]
(SUB) [1]
(SUB) [0]
(SUB)
18
PCI_CLASS
[7]
(PROG) [6]
(PROG) [5]
(PROG) [4]
(PROG) [3]
(PROG) [2]
(PROG) [1]
(PROG) [0]
(PROG)
19
PCI_MISC1
[7]
(MAX_LAT) [6]
(MAX_LAT) [5]
(MAX_LAT) [4]
(MAX_LAT) [3]
(MAX_LAT) [2]
(MAX_LAT) [1]
(MAX_LAT) [0]
(MAX_LAT)
Table 44: Destination of EEPROM Bits Reada (Continued)
Byte
Function
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Chapter 9: The EEPROM Channel
QSpan II User Manual 127
May 16, 2013
9.5 Programming the EEPROM from the QBus or PCI Bus
EEPROM can be accessed from the QBus or the PCI bus, either by a read or write,
using 32-bit writes to the EEPROM_CS register. EEPROM read and write transactions
are described in the following sections.
9.5.1 Writing to the EEPROM
EEPROM values are loaded by the QSpan II when the QSpan II is reset. The user must
reset the QSpan II after writing to the EEPROM through the QSpan II in order to load
new EEPROM data written to the lower 32 bytes.
To write to the EEPROM, complete the following:
1. Read the EEPROM_CS register and make sure that the EEPROM Active (ACT) bit
is set to 0; this indicates prior EEPROM access has completed (see Table 129 on
page 277).
2. Perform a 32-bit write to the EEPROM_CS register.
This write cycle should supply the appropriate values for the ADDR[7:0] and
DATA[7:0] fields, as well as setting the READ bit to 0.
20
PCI_MISC1
[7]
(MIN_GNT) [6]
(MIN_GNT) [5]
(MIN_GNT) [4]
(MIN_GNT) [3]
(MIN_GNT) [2]
(MIN_GNT) [1]
(MIN_GNT) [0]
(MIN_GNT)
21
PCI_MISC1 MISC_CTL2 PCI_PMC
[7]
(INT_PIN0) [6]
(!PCI_DISd)[5]
(PME_SP) [4]
(PME_SP) [3]
(DSI) [2]
(PM_VER) [1]
(PM_VER) [0]
(PM_VER)
22
PCI_BST0 PCI_BST1 Reserved Reserved Reserved Reserved Reserved Reserved
[7] (PREF) [6] (PREF)
a. The top part of each byte row indicates the register name. Bit locations within the register are in square brackets,
and field names are within round brackets.
b. Unlike the other non-reserved bits read from the EEPROM, bit 7 of byte 4, bit 5 of byte 7 and bit 7 of byte 8 are not
written to a QSpan II register. These bits determine whether certain other register bits are loaded from the
EEPROM.
c. If the last three bits of the 12th byte are 010 then the QSpan II will read the next 11 bytes from the EEPROM. If no
further loading is required, these bits must be programmed as 000.
d. PCI_DIS: If 0, PCI_DIS in MISC_CTL2 is set to 1; if 1, it has no effect on the PCI_DIS setting in the MISC_CTL2
register.
Table 44: Destination of EEPROM Bits Reada (Continued)
Byte
Function
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Chapter 9: The EEPROM Channel
QSpan II User Manual128 May 16, 20 13
Writes complete normally on the QBus and the PCI bus regardless of the state of the
ACT bit. However, if the ACT bit is to 1, the write does not change the content of the
EEPROM_CS register. The master is not informed that the EEPROM_CS register
access failed due to the status of the ACT bit (see Table 129 on page 277). To make sure
that the register write has been successful, the user can read from the EEPROM_CS
register after the write.
9.5.2 Reading from the EEPROM
To read from the EEPROM complete the following:
1. Read the EEPROM_CS register and make sure that the ACT bit is set to 0; this
indicates prior EEPROM access has completed (see Table 129 on page 277).
2. W rite the appropriate address in the ADDR[7:0] field of the EEPROM_CS register.
3. Set the READ bit of the EEPROM_CS register to 1 (if it has not already been set).
QSpan II initiates a read from the EEPROM at the address specified in the
ADDR[7:0] field. The ACT bit is cleared (set to 0) when the read completes.
QSpan II stores the read data in the DATA[7:0] field of the EEPROM_CS register.
Only one byte can be read at a time.
4. Read the DATA[7:0] field of the EEPROM_CS register.
9.6 EEPROM Access
QSpan II supports access to the EEPROM after the QSpan II has powered up without
loading from the EEPROM. To access the EEPROM using this method, set the
EEPROM_ACC bit in the MISC_CTL2 register (see Table 130 on page 278). If the
EEPROM_ACC bit is set, the EEPROM related registers are enabled and the QSpan II
can read and write to the EEPROM using the EEPROM_CS register or the Vital
Product Data (VPD) registers.
9.7 Vital Product Data Support
Vital Product Data (VPD) is a PCI 2.2 Specification feature supported by th e QSpan II.
VPD contains information that defines items such as hardware, software, and
microcode elements of a system. VPD also provides a mechanism for storing
information such as performance and failure data on a device. VPD resides in a local
storage device. W ith the QSpan II, VPD is supported through the serial EEPROM. If an
external EEPROM is not used, the VPD feature is not enabled; VPD will not be a part
of the Capabilities List.
Since the lower bytes in the EEPROM contain data for setting up the QSpan II before
software initialization, the lower portion of the EEPROM (first 32 bytes) is not
accessible through the VPD registers. The upper 224 bytes of the 256-byte EEPROM
are designated as read/write through the VPD. Valid VPD byte addresses are 0x0 -->
0xDC, assuming a 2 Kbit serial EEPROM is installed on the board.
Chapter 9: The EEPROM Channel
QSpan II User Manual 129
May 16, 2013
VPD access to the EEPROM is similar to the EEPROM access implemented in
QSpan II through the EEPROM_CS register. Since they both access the same resource,
only one of these mechanisms can be used at a time to access the EEPROM.
9.7.1 Reading VPD Data
QSpan II implements 8 bits of address for accessing the EEPROM (maximum of 256
bytes). The VPD address must be 32-bit aligned. QSpan II will add 0x20 to the VPD
address to generate an EEPROM address in the upper 224 bytes of the EEPROM. A
single read access reads four consecutive bytes starting from the VPD address.
During a read access the VPD address and the VPD flag bit are written (see Table 87 on
page 220). The VPD flag bit must be set to 0 to indicate a VPD read access. QSpan II
sets the VPD flag bit to 1 when it has completed reading the four bytes from the
EEPROM. The VPD flag bit must be polled to identify when the read is complete. Byte
0 (bits 7–0) of the VPD data register contains the data referenced by the VPD address;
bytes 1–3 contain the successive bytes. If PCI_VPD registe r or EEPROM_CS regist er
is written to prior to the flag bit being set to one, the results of the original read
operation are unpredictable.
9.7.2 Writing VPD Data
A write can occur to the upper 224 bytes of the EEPROM. Similar to the read, the
QSpan II adds 0x20 to the VPD address to get the EEPROM address. A single write
operation writes four consecutive bytes starting from the address specified by the VPD
Address.
The VPD data register is written with the 4 bytes of data. Byte 0 (register bits 7–0)
contains the data to be written to the locati on referenced by the VPD address, bytes 1–3
contain the data for the successive bytes. The VPD Address and VPD flag then must be
written. The VPD flag bit must be set to 1 to indicate a VPD write. The VPD flag bit
must be polled to determine when the write to the EEPROM is complet ed. QSpan II sets
the VPD flag bit to 0 when the write is completed. The PCI_VPD or EEPROM_CS
register must not be written while a write operation is taking place, otherwise results are
unpredictable.
If a read or write is attempted to a VPD address above 0xE0, then the QSpan II does not
perform any EEPROM access, and the VPD address will contain the previous value.
Chapter 9: The EEPROM Channel
QSpan II User Manual130 May 16, 20 13
QSpan II User Manual 131
May 16, 2013
Chapter 10: I2O Messaging Unit
This chapter discusses the I2O Messaging Unit capabilities of the QSpan II. The
following topics are described:
“Inbound Messaging” on page 132
“Outbound Messaging” on page 133
“I2O Operation” on page 134
“Summary of I2O Operations” on page 134
“I2O Interrupts” on page 137
10.1 Overview
QSpan II’s I2O Messaging Unit reduces Host processor utilization by using an I/O
processor to complete I/O transactions. QSpan II is compliant with
I2O Specification 1.5.
QSpan II complies with the I2O specification by enabling intelligent I/O cards — also
called IOP agents — to implement four FIFOs in QBus memory (see Figures 18
and 1 7). These FIFOs queue Message Frame Addresses (MFAs) which point to
message frame locations. There are two FIFOs for inbound messages and two FIFOs for
outbound messages: Inbound Free_List FIFO (IF_FIFO), Inbound Post_List FIFO
(IP_FIFO), Outbound Free_List FIFO (OF_FIFO), and Outbound Post_List FIFO
(OP_FIFO).
There are two pointers for each circular FIFO or queue: Top, referred to as Tail in the
I2O Specification; and Bottom, referred to as Head in the I2O Specification. Therefore,
there are eight pointer registers for the four FIFOs in QSpan II register space. These
pointers are offsets from a fixed QBus address (QBus_I2O_Base_Address or QIBA).
QIBA is aligned to a 1 Mbyte boundary. The four I2O FIFOs must be the same size; the
start address for each FIFO must also be aligned to the FIFO size boundary. Writes to
the queue add an MFA to the Top of the FIFO, and reads draw a n MFA from the Bottom
of the FIFO.
Chapter 10: I2O Messaging Unit
QSpan II User Manual132 May 16, 20 13
Figure 17: I2O Messaging Unit — Functional Diagram
10.2 Inbound Messaging
The Inbound Post_List FIFO (IP_FIFO) contains MFAs for message frames that are
sent from the host, or other IOPs on the PCI bus, to QBus memory. The Inbound
Free_List FIFO (IF_FIFO) contains MFAs for message frames that are free to be filled
by the sender. The sender , which can be either the host or other IOPs, receives the MFA
from the Bottom of the IF_FIFO and writes a message to the shared QBus memory at
the address pointed to by the MFA. The sender then posts the MFA for the message
frame in the inbound queue register, which is at offset 0x040 from the I2O PCI Base
Address Register I2O_BAR at offset 0x010.
When this occurs, the QSpan II writes this MFA to the Top of the Inbound Post_List
FIFO and generates a QBus interrupt, if enabled. The Host (for example, MPC860) then
picks up the MFA from the Bottom of the Inbound Post_List FIFO, processes the
message, and then releases the MFA by posting it to the Top of the Inbound Free_List
FIFO. The PCI host reads from the Inbound queue (offset 0x040) to see if there is an
MFA available for a new posting. If the Inbound Free_List FIFO is empty, the QSpan II
returns 0xFFFF_FFFF to the PCI Host or IOP on the PCI bus.
PCI
Target
Module
PCI
Master
Module
QBus
Master
Module
QBus
Slave
Module
PCI
Interface QBus
Interface
PCI
Bus
Interrupt Channel
Register Channel
QBus
I2O Messaging
Chapter 10: I2O Messaging Unit
QSpan II User Manual 133
May 16, 2013
Figure 18: I2O Implementation
10.3 Outbound Messaging
The Outbound Post-List FIFO (OP_FIFO) contains MFAs for message frames sent to
system memory from the QBus Host. The Outbound Free-List FIFO (OF_FIFO)
contains MFAs for message frames that are free to be filled by the QBus Host. The
QBus Host gets an MFA from the Bottom of the Outbound Free-List FIFO, write s a
message to system memory and then posts the MFA to the Top of the OP_FIFO.
QSpan II generates a PCI interrupt (if enabled) when an MFA is posted. The host
accesses the oldest outbound MFA by reading the outbound queue. The outbound queue
is offset 0x044 from the I2O_BAR at offset 0x010.
Outbound
Free_List
FIFO
(OF_FIFO)
Write to Outbound Queue
Read from Outbound Queue
External PCI
Host
IOF_TP (incremented by QSpan II)
IOP_BP (incremented by the QSpan II)
Write to Inbound Queue
Read from Inbound Queue
External PCI
Host
IIP_TP (incremented by the QSpan II)
IIF_BP (incremented by the QSpan II)
Write to Register
QBus CPU
IOF_BP (incremented by QBus CPU)
Read from Register
IOP_TP (incremented by QBus CPU)
Write to Register
QBus CPU
IIP_BP (incremented by QBus CPU)
Read from Register
IIF_TP (incremented by QBus CPU)
QBus Low Memory Address
QBus High Memory Address
Inbound
Free List
FIFO
(IF_FIFO)
Outbound
Post_List
FIFO
(OP_FIFO)
Inbound
Post_List
FIFO
(IP_FIFO)
Chapter 10: I2O Messaging Unit
QSpan II User Manual134 May 16, 20 13
QSpan II then supplies the data from the Bottom of the Outbound Post-List FIFO. If the
Outbound Post-List FIFO is empty, the QSpan II returns 0xFFFF_FFFF to the PCI Host
or IOP on the PCI bus. The PCI host allocates available system message frames to the
QBus Host by writing an available MFA to the outbound queue at offset 0x044.
QSpan II then writes this MFA to the Top of the Outbound Free-List FIFO in QBus
memory.
10.4 I2O Operation
When the QSpan II is enabled for I2O operation — I2O Enable (I2O_EN) in register
I2O_CS — the base address register for PCI Target Image 0 (PCI_BST0) is moved to
the first base address register in the Configuration space (offset 0x010), and is renamed
I2O_BAR. The base address register for accessing the QSpan II registers from PCI
(PCI_BSM) is then moved from of fset 0x010 to 0x018 (for more information, see “I2O
Messaging Unit Initialization” on page 386). The QBus translation address and other
QBus options can be set in PBTI0_CTL and PBTI0_ADD for message passing from the
Host to the QBus memory. The bottom 4 Kbytes of the I2O_BAR is not translated into
QBus memory.
In this 4 Kbyte region, 16 bytes are predefined for I2O operation, offsets 0x030 and
0x034 are used for system interrupt generation, and offsets 0x040 and 0x044 are
defined as the location of the Inbound and Outbound qu eues. Each inboun d MFA is the
offset between the start of the memory region specified by the I2O base address
Configuration register (I2O_BAR) and the start of the message. The inbound MFAs
must be above the 4 Kbyte region (for example, Inbound MFAs must be greater than
FFFh). Each outbound MFA is specified as the offset from Host memory location
(0000_0000h) to the start of the message frame in shared Host memory.
10.5 Summary of I2O Operations
10.5.1 Initialization
The following initialization operation allows the QSpan II to take part in I2O
operations:
1. The QBus Host reserves a number of memory locations in its local memory to hold
inbound I2O messages. The locations do not have to be contiguous. It then creates a
FIFO (IF_FIFO) that contains the address to these memory locations (MFAs). It
creates another FIFO (IP_FIFO) that contains th e Inbound Post_List MFAs. The
QBus Host then creates two more circular FIFOs: OF_FIFO and OP_FIFO.
All four FIFOs must be the same size. They can be anywhere in a 1 Mbyte window
(from the base address defined by QIBA in I2O_CS register), without overlapping.
The four FIFOs are required to be in the same 1 Mbyte window so that the upper 12
bits ([31..20]) are the same for the eight pointers maintained by the QSpan II.
Chapter 10: I2O Messaging Unit
QSpan II User Manual 135
May 16, 2013
2. The QBus Host then programs the Inbound Free_List pointers in the QSpan II
registers. The I2O Inbound Free_List Bottom Pointer (IIF_BP) must point to the
I2O location in the Inbound Free_List FIFO (for example, if the location of
IF_FIFO is at QIBA, then IIF_BP = 0). The I2O Inbound Free_List Top Pointer
(IIF_TP) must point to the first free entry (for example, last available MFA + 1).
If the size of the FIFO is 256, and there are 200 MFAs, then IIF_TP = 201 * 4 = 804
(0x324). The Inbound Post_List Top and Bottom (IIP_TP, IIP_BP) pointers must
also be programmed (for example, if the IP_FIFO starts at (QIBA + 2048), then
IIP_BP = IIP_TP = 2048). The four Outbound pointers: I2O Outbound Post_List
Top Pointer (IOP_TP), I2O Outbound Post_List Bottom pointer (IOP_BP), I2O
Outbound Free_List Top Pointer (IOF_TP), I2O Outbound Free_List Bottom
Pointer (IOF_BP), must be programmed to their respective starting offset—from
the QIBA (for example, if OP_FIFO starts at (QIBA + 4096) and OF_FIFO starts
at (QIBA + 6144), then IOP_BP = IOP_TP = 4096, and IOF_BP = IOF_TP =
6144).
If the QBus I2O base address is 0xA000_0000, then QSpan’s I2O registers will
contain the following for the above settings.
I2O_CS: QIBA = 0xA00, FIFO_SIZE = 0x0
IIF_BP = 0xA000_0000, IIF_TP = 0xA000_0324 (IF_FIFO contains 200 MFAs)
IIP_BP = 0xA000_0800, IIP_TP = 0xA000_0800 (IP_FIFO is empty)
IOP_BP = 0xA000_1000, IOP_TP = 0xA000_1000 (OP_FIFO is empty)
IOF_BP = 0xA000_1800, IOF_TP = 0xA000_1800 (OF_FIFO is empty).
3. The QBus Host enables I2O (bit I2O_EN in register I2O_CS) and enables ac c es s
from the PCI bus to the QSpan II (clear bit PCI_DIS in register MISC_CTL2).
4. The Host, with a mechanism similar to step 1 above, reserves a number of memory
locations to hold Outbound I2O messages. It then writes the address of these
locations (MFAs) to the OF_FIFO (see “Inbound I2O Message” on page 136. This
causes the QSpan II to update the IOF_TP pointer (for example, if the Host writes
100 MFAs into OF_FIFO, then IOF_TP = 6144 + 4*101 = 6548).
QSpan II’s registers now contain the following:
IOF_BP = 0xA000_1800
IOF_TP = 0xA000_1994 (OF_FIFO contains 100 MFAs)
If the Top and Bottom pointers are equal, the FIFO can either be full or
empty. QSpan II assumes tha t the FIFO is empty when the pointers are
equal at start-up. To indicate that the FIFO (for example, the IF_FIFO) is
full at start-up, the QBus Host needs to first program the Top pointer to
the top of the FIFO, and then increment it by four. This places the Top
pointer at the bottom of the FIFO.
Chapter 10: I2O Messaging Unit
QSpan II User Manual136 May 16, 20 13
10.5.1.1 Inbound I2O Message
1. The host gets an MFA by reading from offset 0x040 from the first Base Address
Register (I2O_BAR). This causes the QSpan II to generate a QBus delayed read
cycle at address (IIF_BP = 0xA000_0000) to get the first MFA. When the read data
is available, the QSpan II returns the data to the Host. QSpan II also increases the
IIF_BP pointer by 4 (IIF_BP = 0xA000_0004).
2. The Host writes the I2O message to the shared local memory through the
QSpan II using the offset specified by the MFA from I2O_BAR.
3. The Host then places the MFA into the IP_FIFO (for example, the Host writes to
offset 0x040 with MFA as the da ta). This causes the QSpan II to generate a QBus
delayed write cycle at address (IIP_TP = 0xA000_0800) with MFA as the data.
QSpan II also increases the IIP_TP pointer by four (IIP_TP = 0xA000_0804).
QSpan II can be programmed to generate a QBus interrupt when the IP_FIFO is
written with a new MFA. It also sets the Inbound Post_List New Entry Interrupt
Status (IPN_IS) bit in the INT_STAT register (see Table 119 on page 260).
4. The QBus Host is notified of the Inbound message either through the QBus
interrupt, or by polling IP_FIFO Empty Status (IP_E) bit in the I2O_CS register
(see Table 109 on page 246). It then reads the QSpan II’s IIP_BP register to get the
next Bottom pointer in the Inbound Post_List FIFO (this is a normal QBus register
access). The QBus Host can then get the MFA for the message and process the
message. The QBus Host must complete a write to increment the IIP_BP by four
(IIP_BP = 0xA000_0804) to point to the next MFA in the IP_FIFO.
5. The QBus Host releases the used MFA by writing the MFA back to the IF_FIFO (at
the Top pointer). It must also increment the QSpan II’s IIF_TP pointer by four
(IIF_TP = 0xA000_0 328 ) using a QBus reg ister access.
10.5.1.2 I2O Outbound Message
1. The QBus Host gets a pointer to the location of an MFA for the outbound message
by reading the QSpan II’s Outbound Free_List Bottom Pointer (IOF_BP). It needs
to increase the IOF_BP by four (IOF_BP = 0xA000_1804) to point to the next
MFA (these are done through QBus register access).
2. The QBus Host writes the message to the host memory location pointed by the
MFA.
3. The QBus Host places the MFA in the OP_FIFO (using the Top pointer). It also
needs to increment the QSpan II’s Outbound Post_List Top Pointer register
(IOP_TP) by four (IOP_TP = 0xA0 00 _1 004). QSpan II generates a PCI interrupt
(if not masked by the bit OP_IM in register I2O_OPIM) when the OP_FIFO is not
empty and sets the OP_ISR bit in the I2O_OPIS register (see Table 150 on
page 294).
The incrementing is completed by the QBus Host. It writes the new value
of the pointer to the IIP_BP register.
Chapter 10: I2O Messaging Unit
QSpan II User Manual 137
May 16, 2013
4. The Host is notified of the Outbound message either through the PCI interrupt or
by polling the status bit. It then initiates a PCI memory read access at offset 0x044
from the first BAR in the QSpan II’s Configuration space (I2O_BAR) to get the
MFA. This causes the QSpan II to generate a QBus delayed read cycle at address
(IOP_BP = 0xA000_1 000). When the read data is returned to the QSpan II, the
data is passed back to the Host. QSpan II also increases the IOP_BP by four
(IOP_BP = 0xA000_10 04 ) . The OP_ISR status bit is cleared if the OP_FIFO is
empty.
5. The Host processor then reads the message pointed by the MFA and consumes it.
6. The Host then releases the used MFA by writing to offset 0x044 from I2O_BAR
(see Table 74 on page 207).
This causes QSpan II to generate a QBus write cycle at address (IOF_TP =
0xA000_1994) with the MFA as the data. Upon completion of the write, the
QSpan II increments the IOF_TP by four (IOF_TP = 0xA000_1998).
10.6 I2O Interrupts
QSpan II provides status bits in I2O Control and Status (I2O_CS) register for each of
the four I2O list FIFOs to indicate if they are empty or full (see Table 100 on page 236).
A PCI interrupt can be generated when the Outbound Post_List FIFO contains MFAs
(for example, when the Outbound Post_Li st FIFO is not empty). The interrupt can be
masked by setting the OP_IM bit in I2O_OPIM register. The corresponding status bit is
in I2O_OPIS register. A copy of this status bit is also provided in the INT_STAT
register.
To generate a QBus interrupt when a new MFA is posted into the Inbound Post_List
FIFO, set the IPN_EN bit in INT_CTL (see Table 120 on page 263). If the interrupt is
generated, the IPN_IS status bit is set. The QBus interrupt can be negated by writing a 1
to the IPN_IS status bit.
The following four conditions can also cause external interrupts: Inbound Free_List
FIFO empty, Outbound Free_List FIFO empty, Inbound Post_List FIFO full and
Outbound Free_List FIFO full. These interrupts are enabled by setting the
corresponding bits in the INT_CTL and INT_DIR registers.
The four pointers updated automaticall y by QSpan II are IIF_BP, IIP_TP,
IOP_BP and IOF_TP. When the pointer is at the top of the FIFO, the next
increment puts it at the bottom of the FIFO: the increments are
accomplished on a modulo boundary of the FIFO_SIZE. The other four
pointers (IIF_TP, IIP_BP, IOP_TP and IOF_BP) must be incremented by
the QBus Host. This is achieved by completing a QBus register write with
the new pointer value. The two Top pointers incremented by t he QSpan II
(IIP_TP and IOF_TP) are not incremented if the corresponding FIFO
becomes full. Likewise, the two Bottom pointers (IIF_BP and IOP_BP)
are not incremented if the corresponding FIFO is empty.
Chapter 10: I2O Messaging Unit
QSpan II User Manual138 May 16, 20 13
QSpan II User Manual 139
May 16, 2013
Chapter 11: PCI Bus Arbiter
This chapter explains the QSpan II’s PCI bus arbiter. The following topics are
discussed:
“Arbitration Scheme” on page 140
“Bus Parking” on page 142
11.1 Overview
QSpan II has an integrated PCI bus arbiter with dedicated support for the QSpan II PCI
master, and up to seven external Masters (see Figure 19). The PCI bus arbiter uses a
fairness algorithm to prevent deadlocks.
QSpan II’s PCI bus arbiter is enabled at power-up if the PCI_ARB_EN pin is sampled
high at the negation of Reset. The request lines of the external bus Masters can be
connected to the REQ# and EXT_REQ#[6:1] pins. Any unused request pins must be
externally pulled up. The grant lines of the external bus Masters can be connected to
GNT# and EXT_GNT#[6:1]. If an external arbiter is used, the QSpan II uses the
REQ#/GNT# line to acquire the PCI bus. QSpan II drives the unused EXT_REQ#[6:1]
and EXT_GNT#[6:1] high when an external arbiter is used.
Chapter 11: PCI Bus Arbiter
QSpan II User Manual140 May 16, 20 13
Figur e 19 : PCI Bus Ar bi te r — Functional Diag ra m
11.2 Arbitration Scheme
To maintain arbitration fairness, the PCI bus arbiter assigns bus masters to one of two
priority levels: Level 0 or Level 1 (see Figure 20). Bus Masters assigned to Level 0 are
of lower priority than Masters assigned to Level 1. Bus Masters assigned to the same
level have equal priority in the arbitration scheme. Bus Masters on Level 0 get a single
access during each round-robin arbitration on Level 1. Arbitration is performed among
Masters asserting request to the QSpan II’s PCI bus arbiter. The bus arbiter removes a
grant to a master if it has not started an access after its grant has been issued and the bus
is in the idle state for 16 clock cycles.
PCI
Target
Module
PCI Bus
Arbiter
PCI
Master
Module
QBus
Master
Module
QBus
Slave
Module
PCI
Interface QBus
Interface
PCI
Bus QBus
QBus Slave Channel
Q-FIFOs
PCI Target Channel
P-FIFOs
Chapter 11: PCI Bus Arb iter
QSpan II User Manual 141
May 16, 2013
Figur e 20: PCI Bus Arbiter — Arbi tration Scheme
To assign a priority level, set the Arbitration Level priority (Mx_PRI) bit in the
PARB_CTL register (see Table 131 on page 281). Background arbitration is
implemented, which means arbitration occurs during the previous access so that no PCI
cycles are consumed due to arbitration; except when the bus is in the idle state.
In general, the arbiter negates the current grant when the current master asserts
FRAME#. It issues a new grant when the current master negates FRAME# if there is a
pending new request. If the bus is idle when a new request is received, the arbiter
negates the current grant, then issues a new grant on the next clock.
Master X
Master Y
Master Z
Level 0
Master C
Level 0
Master A
Master B
Level 1
Arbitration Order
Level 1, Level 1, Level 1, Level 0
For example, if all bus masters
assert Request:
* A, B, C, X
* A, B, C, Y
* A, B, C, Z
Chapter 11: PCI Bus Arbiter
QSpan II User Manual142 May 16, 20 13
11.3 Bus Parking
Bus parking is supported on the last bus master or on a pre-determined bus master . This
depends on the setting of the PCI Bus Parking Scheme (PARK) bit and the Select
Master for PCI Bus Parking (BM_PARK) bit in the PARB_CTL register (see Table 131
on page 281). If PARK is set to 0, the last bus master is parked. If PARK is set to 1, the
bus master identified by BM_PARK is parked.
Bus parking is performed when there are no requests and the bus is idle.
QSpan II User Manual 143
May 16, 2013
Chapter 12: CompactPCI Hot Swap Friendly
Support
This chapter discusses CompactPCI Hot Swap Friendly capabilities of the QSpan II.
The following topics are explained:
“Hot Swapping with the QSpan II” on page 144
“CompactPCI Hot Swap Card Insertion” on page 145
“CompactPCI Hot Swap Card Extraction” on page 147
12.1 Overview
QSpan II is a CompactPCI Hot Swap Friendly Device (see Figure 21). CompactPCI’s
Hot Swap Specification defines a process for installing and removing adapter boards
without adversely affecting a running system. QSpan II supports programmable access
to Hot Swap services. This allows system reconsideration and fault recovery to take
place with no system down time and minimum operator interaction.
Hot Swap defines three classes of devices: Hot Sw ap Capable, Hot Swap Friendly and
Hot Swap Ready. Hot Swap Friendly device requirements include the following:
Hot Swap Control/Status Register and Exte nded Capabilities Pointer: This supports
the use of the Hot Plug System Driver.
Support of the Hot Swap event pin ENUM#: This signal informs the Host that the
configuration of the system has changed; that is, the card has been inserted or is
about to be removed.
Support for sensing the switch connected to the ejector latch, and controlling the
LED: Two pins are used for this functionality, HS_SWITCH (Input) to detect the
state of the ejector latch and HS_LED (Open-Drain Output) to control the LED.
Chapter 12: CompactPCI Hot Swap Friendly Support
QSpan II User Manual144 May 16, 20 13
Figur e 21 : Co mpactPCI Hot Swap — Functional Diagra m
12.2 Hot Swapping with the QSpan II
The CompactPCI Hot Swap Specification defines a switch located in the ejector handle
that indicates to QSpan II if the ejector ha ndle is open or closed. The specification also
defines a LED that can be controlled by hardware and software, by setting the LED
On/Off (LOO) bit in the CPCI_HS register (see Table 86 on page 219). QSpan II drives
the HS_LED signal low to turn on the LED during the Physical and Hardware
Connection process (when HS_HEALTHY_ is high), and when the LOO bit is set, to
minimize the number of external components. A blue LED with an internal resistor can
be directly connected between the 5V rail and the HS_LED pi n.
A low value on HS_SWITCH input indicates that the ejector latch is open. A high value
on HS_SWITCH indicates that the ejector latch is closed. QSpan II tri-states the
HS_LED signal low when the LED is supposed to be turned-off during normal
operation.
PCI
Target
Module
PCI Bus
Arbiter
PCI
Master
Module
QBus
Master
Module
QBus
Slave
Module
PCI
Interface QBus
Interface
PCI
Bus
Interrupt Channel
Register Channel
QBus
(Processor Bus)
I
2
O Messaging
CompactPCI
Hot Swap
QBus Slave Channel
Q-FIFOs
PCI Target Channel
P-FIFOs
IDMA/DMA Channel
I-FIFO (IDMA)
I-FIFO (DMA)
8091862.BK001.01
Chapter 12: CompactPCI Hot Swap Friendly Support
QSpan II User Manual 145
May 16, 2013
QSpan II also monitors the board healthy signal (HEALTHY# in the Hot Swap
specification). This connects to QSpan II’s input signal, HS_HEALTHY_. QSpan II
internally OR’s the HS_HEALTHY_ and PCI Reset (RST#) to generate an internal
reset. When HS_HEALTHY_ is high, the QSpan II is in reset and all outputs are
tri-stated (except for HS_LED). QSpan II will drive out RESETO_ low due to a PCI
Reset (RST# low) if HS_HEALTHY_ is low, indicating that the back-end is powered
up. QSpan II samples the power-up option pins (BDIP_, PCI_DIS, etc.) on
HS_HEALTHY_ going low (as well as RST# going high or RESETI_ going high).
12.3 CompactPCI Hot Swap Card Insertion
When a CompactPCI add-in card containing QSpan II is inserted into a powered-on
system, power and ground are first supplied to the QSpan II. The remaining subsystem
components do not have power. From the long pins, the HEALTHY# signal is generated
and applied to QSpan II (HS_HEALTHY_). This causes the QSpan II to generate an
internal reset, to drive HS_LED low, and to tri-state all other outputs.
When the board is fully inserted and power is supplied to the rest of the subsystem (or
back-end), the HS_HEALTHY_ can be asserted low, causing the QSpan II to come out
of reset. If the PCI Reset (RST#) is active low at this time, the QSpan II drives out
RESETO_ low until RST# is negated. On the assertion of HS_HEALTHY_ or the
negation of RST# (if RST# was active when HS_HEALTHY_ was asserted), the
QSpan II loads from the EEPROM (if enable d). After the EEPROM loading, the
QSpan II sets the Insertion (INS) bit in CPCI_HS register, signals the Host using
ENUM# (if enabled), and accepts Configuration cycles from the Host.
QSpan II can also be set — using a power-up option, PCI_DIS — to hold off asserting
ENUM# and retry Configuration cycles while the QBus Host programs the QSpan II’s
Configuration registers. At the end of this programming, the PCI_DIS bit in the
MISC_CTL2 register (see T a ble 130 on page 278) can be cleared to enab le the QSpan II
to set the INS bit, to assert ENUM#, and to accept Configuration cycles from the Host.
The Host can clear ENUM# by writing to the INS or EIM bit in CPCI_HS register. The
Host can then configure the QSpan II-based add-in card.
Chapter 12: CompactPCI Hot Swap Friendly Support
QSpan II User Manual146 May 16, 20 13
Table Legend of Insertion Sequence:
HS_LED = L LED on
HS_LED = Z LED off
HS_HEALTH Y_ = High Back-end powered down
HS_HEALTHY_ = Low Back-end po wered up
The bits INS, EXT, LOO and EIM are defined in CPCI_HS register.
Table 45: Insertion Sequence
Event HS_
HEALTHY_ ENUM# HS_LED HS_SWITCH LED INS EXT LOO EIM
Long pins
connect High Z L open on 0 0 0 0
Medium pins
connect High Z L open on 0 0 0 0
Short pins
connect High Z L open on 0 0 0 0
HS_
HEALTHY_
asserteda
Low Z L open on 0 0 0 0
Turn off LED Low Z Z open off 0 0 0 0
Close Ejector
latch Low Z Z closed off 0 0 0 0
Drive ENUM# Low L Z closed off 1 0 0 0
Host clears
ENUM# Low Z Z closed off 0 0 0 0
a. QSpan II will load from external EEPROM, if enabled.
Chapter 12: CompactPCI Hot Swap Friendly Support
QSpan II User Manual 147
May 16, 2013
Figure 22: Hot Swap Card Insertion1
12.4 CompactPCI Hot Swap Card Extraction
The extraction process is signaled by opening the ejector handle; this causes the
HS_SWITCH to be low. When QSpan II detects the falling edge on HS_SWITCH, it
starts the extraction process. It sets the EXT bit in CPCI_HS (see Table 86 on page 219)
and asserts ENUM#, if it is enabled.
After sensing ENUM# or detecting the EXT bit set in CPCI_HS (from polling), the
Host software writes to the EXT bit to clear the EXT bit and negate ENUM#. It also
brings the card to a quiescent state and then writes to the LOO bit to turn on the LED.
This indicates to the operator that the board is ready to be extracted.
1. This graphic is from the CompactPCI Hot Swap Specification.
EXT bit
INS bit
LED
ENUM#
Ejector State
PCI Signals
PCI Clock
PCI RST#
HEALTHY#
BD_SEL#
Back End Power
Early Power
Med
Engage Short
Engage Fully
Seated
Clocking
Closed
Open
Engaged, tracking bus
Cleared/Unarmed Cleared/Armed
LED off
Cleared/Unarmed
Set
Cleared/Unarmed
Physical Connection Hardware Connection Start of Software Connection Process
LED on by Hardware
pre-charge
Pulled up
Long
Engage Back-End Powered
Board goes Healthy
(from J1)
pre-charge
pre-charge
pre-charge
QSpan Clears
LOO bit Ejector
Latched
Chapter 12: CompactPCI Hot Swap Friendly Support
QSpan II User Manual148 May 16, 20 13
As the board is removed fro m the system, the short pin breaks contact and the
HS_HEALTHY_ pin is negated, causing the QSpan II to tri-state the outputs (except
HS_LED, to keep the LED on until the long pins disengage).
Table Legend of Extraction Sequence:
HS_LED = L --> LED On,
HS_LED = Z --> LED Off.
The bits INS, EXT, LOO and EIM are defined in CPCI_HS register.
HS_HEALTH Y_ = H --Back-end powered down,
HS_HEALTHY_ = L --> Back-end powered up
Instead of taking the board out when the LED is on, the operator can close
the ejector latch to indicate an insertion process. In this case, the insertion
sequence will begin from event Close Ejector Latch, and the QSpan II
will not load from the EEPROM unless HS_HEALTHY_ is negated or
RST# is asserted prior to closing the ejector latch.
Table 46: Extraction Sequence
Event HS_
HEALTHY_ ENUM# HS_LED HS_SWITCH LED INS EXT LOO EIM
Normal
Operation L Z Z closed off0000
Ejector Open L Z Z open off0000
Drive ENUM# L L Z open off0100
Host detects
ENUM# L L Z open off0100
Host clears
ENUM# L Z Z open off0000
Host sets LOO L Z L open on 0 0 1 0
Short pins
breaka
a. The card can be inserted at this point, then the insertion process is started from “Close Ejector Latch” of the
insertion sequence.
H Z L open on 0 0 0 0
Medium pins
break H Z L open on 0 0 0 0
Long pins break X X X X X X X X X
Chapter 12: CompactPCI Hot Swap Friendly Support
QSpan II User Manual 149
May 16, 2013
Figure 23: Hot Swap Card Extraction1
1. This graphic is from the CompactPCI Hot Swap Specification.
EXT bit
INS bit
LED
ENUM#
Ejector State
PCI Signals
PCI Clock
PCI RST#
HEALTHY#
BD_SEL#
Back End Power
Early Power
Ejector
Unlatched SW Clear
EXT bit SW Set
LOO bit Withdrawal
Starts Short
disengage Med.
disengage Long
disengage
Clocking
(from J1)
Closed Open
LED off
Engaged, tracking bus
Cleared/Unarmed Cleared/Armed
LED on by SW
Cleared/Armed Set Cleared/Unarmed
Software Connection Hardware Connection Physical Connection
LED on by HW
pre-charge
pre-charge
pre-charge
pre-charge
Pulled up
Chapter 12: CompactPCI Hot Swap Friendly Support
QSpan II User Manual150 May 16, 20 13
QSpan II User Manual 151
May 16, 2013
Chapter 13: PCI Power Management Event
Support
This chapter explains PCI Power Management Support for the QSpan II. It focusses on
the Power Management Support outpu t signal (PME#).
13.1 Overview
QSpan II provides a PCI Power Management interface that is compliant with PCI Bus
Power Management Interface Specification 1.1. This interface enables the operating
system to control the hardware — an add-in card, for example — that implements
power saving features in a platform-independent manner. The Power Management
interface supports the minimum requirements of powered - up and sleep, or low power,
states.
QSpan II does not implement any power saving features in silicon; it merely passes the
Power Management information between the Host OS and the I/O subsystem. The
Power Management registers can be loaded from the EEPROM or programmed by the
QBus Host before initialization by the Host.
13.2 Power Management Event (PME#) Support
The QSpan II provides support for the PME# output signal. This signal is asserted to
request a change in its current power management state, and/or to indicate that a power
management event has occurred.
QSpan II asserts PME# when the PME_EN bit is set to 1 in the Power Management
Control and Status (PCI_PMCS) register, and if the Power State bits (PWR_ST in
PCI_PMCS) are written to the value in PME_support field in PCI_PMCS register by
the QBus Host. The PME Status bit in PCI_PMCS is set in the above case regardless of
the setting of PME_EN. QSpan II negates PME# if the PME Status bit is cleared or
PME_EN bit is disabled.
Chapter 13: PCI Power Management Event Support
QSpan II User Manual152 May 16, 20 13
Transition between the different power states of the add-in card can be initiated by
either the Host or the QBus Host writing to the Power State bits in the Power
Management Control and Status Register (PCI_PMCS). QSpan II provides multiple
options to allow maximum flexibility:
D0 to D3hot Transition
a. Host initiated:
QSpan II generates a QINT_ if PSC_EN bit in INT_CTL register is set.
b. QBus Host initiated:
QSpan II sets PME_ST bit in PCI_PMCS register (if PME_SP[3]=1, in
PCI_PMC register); it also asserts PME# (if PME_EN=1, in PCI_PMCS).
D3hot to D0 Transition
a. Host Initiated:
If the add-in card needs to be reset, then setting the Power State Change
(PSC_QRST) bit in MISC_CTL2 register causes the QSpan II to generate an
internal QSpan II reset. It also causes RESETO_ signal to be asserted (for 512
to 1024 PCI clocks). QSpan II will load from EEPROM, if enabled.
If the add-in card should no t be reset, then the QSpan II can be programmed to
generate a QINT_ (PSC_EN bit is set in INT_CTL register).
b. QBus Host initiated (QBus Host powered-up and configured):
QBus Host writes to the PWR_ST bits in PCI_PMCS register to change the
power state. QSpan II then sets PME_ST bit in PCI_PMCS register (if
PME_SP[0]=1, in PCI_PMC register), and it also asserts PME# (if
PME_EN=1, in PCI_PMCS).
c. Add-in card initiated (QBus Host in sleep-mode):
QSpan II can be programmed to generate a PME# from the assertion of QINT_
in the D3hot Power state (if QINT_PME=1, in MISC_CTL2 register,
PME_SP[3]=1, in PCI_PMC and PME_EN=1, in PCI_PMCS). PME_ST bit
will also be set.
The Host can then write to the PWR_ST bits in PCI_PMCS to change it to D0,
and generate an add-in card reset.
For more information about PCI power management states, see the PCI Bus Power
Management Inte rface Specification 1.1.
PME# has additional electrical requirements beyond standard an open
drain signal that allows it to be shared between devices which are
powered off, and those that are powered on. This isolation circuitry must
be implemented externally on the add-in card.
QSpan II User Manual 153
May 16, 2013
Chapter 14: Reset Options
This chapter discusses Reset options for the QSpan II. The following topics are
examined:
“Types of Resets” on page 153
“Configuration Options at Reset” on page 155
14.1 Types of Resets
QSpan II can be reset from the QBus or the PCI bus through hardware. QSpan II uses
four pins and one register for reset operation. The reset pins are listed in Table 47.
Table 47: Hardware Reset Mechanisms
Pin Name Interface Direction Function
RST# PCI Input Resets all the QSpan II circuits and registers and asserts
RESETO_ when HS_HEALTHY_ is low. RESETO_
remains asserted until RST# is released. Also clears the
SW_RST bit in the MISC_CTL (see Table 127 on page 274)
register.
RESETI_ QBus Input Resets most of the QSpan II circuits and registers (see
Appendix A: “Registers” on page 193)
RESETO_ QBus O utput Resets devices on the QBus
HS_HEALTHY_ PCI Input This input indicates the state of the back-end system.
The term Reset is used when PCI Reset (RST#) or QBus Reset input
RESET1_ is driven low or HS_HEALTHY_ is driven high.
Chapter 14: Reset Options
QSpan II User Manual154 May 16, 20 13
The QBus Software Reset Control (SW_RST) bit in the MISC_CTL register (see
Table 127 on page 274) controls the QBus Reset output (RESET O_). One of the uses of
this mechanism is to keep the QBus in reset while an operating system and driver are
downloaded to on-board memory. When a 1 is written to the SW_RST bit, the QSpan II
asserts RESETO_ and keeps it asserted until the software reset state is terminated.
There are three ways to cause the QSpan II to terminate the software reset state:
1. Clear the SW_RST bit by writing 0 to it. In this case, RESET O_ is immediately
negated.
2. Assert RESETI_. In this case, the SW_RST bit is immediately cleared (set to 0)
and RESETO_ is immediately negated.
3. Assert RST#. In this case, SW_RST is immediately cleared (set to 0), however
RESETO_ continues to be asserted until RST# is negated.
14.1.1 PCI Transactions during QBus Reset
Assertion of RESETI_ may interfere with the QSpan II’s response to PCI Masters. If a
PCI master attempts to access the QSpan II while RESETI_ is asserted, the QSpan II
will not decode the incoming cycle and a Master -Abort will occur on the PCI bus. If the
QSpan II has already been selected by a PCI master (QSpan II has asserted DEVSEL#),
then the QSpan II will immediately nega te DEVS EL#, but TRDY# and STOP# will not
be asserted by the QSpan II.
14.1.2 IDMA Reset
IDMA reset issues are discussed in “IDMA Errors, Resets, and Interrupts” on page 89.
14.1.3 Clocking and Resets
The PCLK can operate anywhere from DC to 33 MHz. The maximum QCLK frequency
depends on the host processor. For MPC860 applications, the maximum QCLK
frequency is 50 MHz. For MC68360 applications, the maximum frequency is 33 MHz.
The QCLK input is not required to be operating to successfully complete QSpan II
resistor accesses from the PCI bus. QSpan II supports asynchronous assertion and
negation of Resets. Refer to the tables in “Signals and DC Characteristics” on page 177
for a description of the state of each QSpan II pin after reset.
When a PCI reset (RST#) is asserted and HS_HEALTHY_ is low, the QSpan II's
RESETO_ signal will be asserted and negated as shown in Appendix B: “Timing”
on page 299.
We do not recommend RESETO_ being looped back to RESETI_. In
addition, asserting the SW_RST bit does not cause an internal reset of the
QSpan II.
Chapter 14: Reset Options
QSpan II User Manual 155
May 16, 2013
The QCLK and PCLK inputs are necessary for software resets. That is, these clocks are
required in order for the QSpan II to negate RESETO_. This is due to the fact that for a
software reset, the QSpan II's registers must be accessed to cause RESETO_ to negate.
If the QCLK or PCLK input stops toggling then it is impossible to write to the
QSpan II's registers to negate RESETO_.
14.2 Configuration Options at Reset
The following QSpan II configuration options can be determined at Reset:
whether the QSpan II is enabled as a PCI bus master
the master and slave modes of the QBus, which determines the type of cycles that
the QSpan II can generate as a master and accept as a slave
whether the QSpan II loads registers from an EEPROM at reset (see “EEPROM
Loading” on page 156 and “PCI Register Access Option” on page 156)
the test mode (see “Test Mode Pins” on page 157)
PCI access to QSpan II registers
PCI bus arbiter functionality
14.2.1 PCI Bus Master Reset Option
If BM_EN/FIFO_RDY_ is sampled as high while reset is asserted, the QSpan II will set
the Bus Master (BM) bit in the PCI_CS register (see Table 70 on page 201). This
enables the QSpan II as a PCI bus master. If this pin is not connected, an internal
pull-down causes the QSpan II to power-up with the BM bit set to 0.
QSpan II’s QCLK input must be identical to the QBus processors clock
source if transactions are occurring on the QBus. Many applications use
an external low skew PLL clock buffer to generate the clock outputs for
the board (for example, QCLK input for QSpan II). If the buffer’s clock
outputs are not locked to the clock input frequency, then transactions
cannot occur on the QBus — QSpan II must not detect AS_ or T S_ being
asserted.
Chapter 14: Reset Options
QSpan II User Manual156 May 16, 20 13
14.2.2 QBus Master and Slave Modes
QSpan II has four Master and Slave modes that are determined by the BDIP_ and the
SIZ[1] signals at reset. The QBus can be in MC68360 (QUICC), MPC860
(PowerQUICC) or M68040 Master mode. The QBus Slave Module is always capable of
accepting MC68360 signals and either MPC860 or M68040 signals. These reset options
are listed in Table 48.
14.2.3 EEPROM Loading
If either ENID or SDA is sampled high at reset, then the QSpan II will download
register information from the EEPROM (see Chapter 9: “The EEPROM Channel”
on page 121).
14.2.4 PCI Register Access Option
If PCI_DIS is sampled high at reset, the QSpan II will retry all PCI accesses until the
PCI Access Disabled (PCI_DIS) bit in MISC_CTL2 is set to 0 by the QBus processor.
14.2.5 PCI Bus Arbitration Option
If PCI_ARB_EN is sampled high at reset, the QSpan II’s PCI bus arbiter is enabled and
will function as the PCI bus arbiter (for more information, see Chapter 11: “PCI Bus
Arbiter” on page 139).
Table 48: Reset Options for QBus Master and Slave Modesa
a. These options are reset whenever the QSpan II is reset.
Reset sampling
Master Mode Slave Mode
BDIP_ SIZ[1]
0 0 MC68360 MC68360 and M68040
0 1 MC68360 MC68360 and MPC860
1 0 M68040 MC68360 and M68040
1 1 MPC860 MC68360 and MPC860
QSpan II User Manual 157
May 16, 2013
Chapter 15: Hardware Implementation Issues
This chapter briefly describes hardware implementation issue for the QSpan II. The
following topics are discussed:
“Test Mode Pins” on page 1 57
“JTAG Support” on page 158
“Decoupling Capacitors” on page 158
15.1 Test Mode Pins
QSpan II can operate in normal mode or test mode. In test mode, a NAND tree is
activated and all outputs are tristated except for the SCL output pin. The output of the
NAND tree is on the SCL pin.
QSpan II has two test mode input pins (TMODE[1:0]). For normal operations these
inputs must be pulled down. The following table indicates the operation modes of the
QSpan II as a function of the TMODE[1:0] input. At reset the TMODE[1:0] inputs are
latched by the QSpan II to determine the mode of operation. QSpan II remains in this
mode until the TMODE[1:0] inputs have changed and a reset event has occurred.
Table 49: Test Mode Operation
TMODE[1:0] Operation Mode
00 Normal Mode
01 Reserved
10 Reserved
11 NAND Tree/Tristate Outputs
Chapter 15: Hardware Implementation Issues
QSpan II User Manual158 May 16, 20 13
15.2 JTAG Support
The QSpan II includes dedicated user-accessible test logic that is fully compatible with
the IEEE 1149.1 Standard Test Access Port an d Boundary Scan Architecture. The
following pins are provided: TCK, TDI, TDO, TMS, and TRST#.
There is an internal pull-up resistor on TMS which will keep the QSpan II’s JTAG
controller in a reset state without requiring TRST# to be low.
15.3 Decoupling Capacitors
When routing the power (VDD) and ground (VSS) tracks to the QSpan II during board
layout, care should be taken to ensure that the QSpan II is isolated from the power being
supplied to other devices on the board by 0.1uF decoupling capacitors.
It is recommended every fourth VDD/VSS pair has a decoupling capacitor.
QSpan II User Manual 159
May 16, 2013
Chapter 16: Signals
This chapter describes the signals which are supported by the QSpan II. Th e following
topics are discussed:
“MC68360 Signals: QUICC” on page 161
“MPC860 Signals: PowerQUICC” on page 165
“M68040 Signals” on page 169
“PCI Bus Signals” on page 172
“Hot Swap Signals” on page 174
“Miscellaneous Signals” on page 175
“JTAG Signals” on page 176
16.1 Terminology
The following abbreviations are used in this chapter:
in Defines a signal as a standard input-only signal.
out Defines a signal as a standard output-only signal.
t/s Defines a signal as a bidirectional, tristate input/output signal.
s/t/s Defines a signal as a sustained tristate signal that is driven by one owner at
a time.
o/d Defines a signal as an open drain.
Chapter 16: Signals
QSpan II User Manual160 May 16, 20 13
16.2 Overview
QSpan II’s QBus Interface defines a number of signals that can be mapped to MC68360
(QUICC), MPC860 (PowerQUICC), or M68040 buses (see the following table).
Table 50: QBus Signal Names Compared to Motorola Signals
QBus Interface MC68360 MPC860 M68040
BB_/BGACK_ BGACK_ BB_ BB_
BERR_/TEA_ BERR_ TEA_ TEA_
BURST_/TIP_ N/A BURST_ TIP_
DACK_/SDACK_ DACK_ SDACK_ N/A
DSACK1_/TA_ DSACK1_ TA_ TA_
SIZ[1:0] SIZ[1:0] TSIZ[0:1] SIZ[1:0]
TC[3:0] FC[3:0] AT[0:3] TT[1:0]
TM[2:0]a
a. TC[3:0] can be connected to four out of the five TT[1:0] and TM[2:0] M68040 signals. The
unused TC pins, if any, must be connected to pull-up resistors (see Appendix C: “Typical
Applications” on page 359).
HALT_/TRETRY_ HALT_ TRETRY_ N/A
MPC860 signals do not necessarily operate in the same manner as
MC68360 signal s of the same name.
Chapter 16: Signals
QSpan II User Manual 161
May 16, 2013
16.3 MC68360 Signals: QUICC
A[31:0] Tristate bidirectional
Address Bus: address for the current bus cycle. It is driven by the QSpan II when it is the QBus master and input
when QBus slave. It is qualified at the start of a transaction by AS_.
As a slave, the QSpan II samples A[31:0] on the same falling edge of the QCLK as AS_. Both A[31:0] and AS_ must
meet the synchronous set-up and hold time parameters about the falling edge of the QCLK to ensure correct
operation.
As a master, the QSpan II maintains the correct asynchronous timing relationships between A[31:0] and AS_. The
address bus is driven valid after the rising edge of the QCLK, while the AS_ is driven only after the subsequent
falling edge of the same clock period, ensuring the correct address before AS_ timing.
When accesses are made to QSpan II registers from the QBus, only the lower 12 bits of the address bus are used to
determine the offset.
AS_ Rescinding Tristate bidirectional
Address Strobe: indicates the beginning (and duration) of a transaction on the QBus.
As an output AS_ is driven by the QSpan II when the QSpan II is the QBus master , and is tristated at all other times.
The Address Strobe is driven low after a falling edge of the QCLK. The Address Strobe qualifies the fo llowing
signals as valid when it is asserted: A[31:0], TC[3:0], SIZ[1:0], and R/W_. QSpan II guarantees a minimum set-up
time for the qualified signals before AS_ is asserted (all qualified signals are driven from the rising edge of QCLK
preceding the assertion of AS_). QSpan II rescinds AS_ prior to tristate.
As an input, AS_ is sampled on the falling edge of the QCLK. AS_ must meet a minimum set-up and hold time
around the falling edge of the clock for correct operation. QSpan II recognizes a transaction as intended for it, and
acknowledges it accordingly, only if one of CSREG_ or CSPCI_ is sampled low in conjunction with AS_. QSpan II
does not require that the input signals qualified by the AS_ be valid when it is asserted.
BB_/BGACK_ Rescinding Tristate bidirectional
Bus Busy: indicates ownership of the QBus. It, along with BR_ and BG_, provides the three-wire handshake for
QBus arbitration. BB_/BGACK_ is intended to connect to the BGACK_ bus.
As an output the QSpan II asserts BB_/BGACK_ from the falling edge of QCLK (while master). QSpan II rescinds
BB_/BGACK_ prior to tristate.
As an input, the QSpan II double-samples BB_/BGACK_ on the falling edge of QCLK: when it is master. QSpan II
can also be programmed to use a synchronous mode for QBus arbitration.
BGACK_ Rescinding Tristate bidirectional
See BB_/BGACK_
BDIP_ Input (MC68360 mode) / Bidirectional (MPC860)
Burst Data In Progress: On the MC68360 interface, this pin is used only to determine the QBus master mode of the
QSpan II. This is determined at reset by sensing the level of this pin. If BDIP_ is sa mpled as low (at power-up or
reset) the QBus master module will operate as an MC68360 master. If the BDIP_ signal is sampled as high — at
power-up or reset — the QSpan II will operate as an MPC860 master (see Table 48 on page 156).
Chapter 16: Signals
QSpan II User Manual162 May 16, 20 13
BERR_/TEA_ Rescinding tristate birectional pin
Bus Error: used to indicate a bus error that occurs during a transaction. It can be used in conjunction with
HALT_/TRETRY_ to indicate a busy-retry to the bus master.
As an MC68360 master, the QSpan II samples BERR_/TEA_ on the falling edge of QCLK during cycles in which it
is a QBus master.
As an MC68360 slave, BERR_/TEA_ is driven by the QSpan II from the falling edge of QCLK. QSpan II negates
BERR_/TEA_ prior to tristate.
BG_ Input
Bus Grant: indicates that the QSpan II may become the next QBus master . BG_, along with BR_ and BB_/BGACK_,
provide the three-wire handshake for QBus arbitration.
BG_ is doubled-sampled on the falling edge of QCLK. QSpan II can be programmed to use a synchronous mode for
QBus arbitration.
BM_EN/
FIFO_RDY_ Bidirectional
Bus Master Enable/FIFO Ready: If this input is asserted — set as 1 — during a PCI Reset, the Bus Master Enable bit
in the PCI_CS register will be set.
BR_ Output
Bus Request: used by the QSpan II to request ownership of the QBus. BR_, along with BG_ and BB_/BGACK_,
provide the three-wire handshake for QBus arbitration.
BR_ is asserted and negated from the falling edge of QCLK in MC68360 mode.
CSPCI_ Input
PCI Chip Select: indicates that the current transaction on the QBus is an access to the PCI Bus. During IDMA cycles,
if this is sampled high, a single address transfer is indicated; if sampled low, a dual address transfer is indicated. It is
sampled on the falling edge of clock.
CSREG_ Input
Register Chip Select: indicates that the current transaction on the QBus is an access to the QSpan II’s registers.It is
sampled on the falling edge of clock.
D[31:0] Tristate bidirectional
Data Bus: provides the data information for the QSpan II’s inputs and outputs on the QBus.
As an MC68360 slave the QSpan II does not use DS_ to qualify data on writes. It also provides data on reads without
decoding DS_, since DS is output only.
As an MC68360 master, the QSpan II does use DS to qualify data on writes and to request data on reads.
DACK_/SDACK_ Input
IDMA Acknowledge: indicates to the QSpan II that the current transaction is an IDMA transaction. The timing of
DACK_ should be the same as for AS_. Using the IDMA handshakes, the QSpan II is capable of supporting
MC68360 fast termination cycles.
16.3 MC68360 Signals: QUICC (Continued)
Chapter 16: Signals
QSpan II User Manual 163
May 16, 2013
DONE_ Input
IDMA Done: indicates that the IDMA controller has completed the current sequence of IDMA operations, and that
the QSpan II should no longer use DREQ_ to request transactions. Setup for DONE is to falling edge of QCLK.
DREQ_ Output
IDMA Request: request to the MC68360 IDMA to either transfer data to QSpan II IFIFO (PCI W rite) or remove data
from I-FIFO (PCI Read). It is asserted from the falling edge of QCLK in MC68360 mode.
DSACK0_ Rescinding tristate bidirectional
Data and Size Acknowledge 0: in conjunction with DSACK1_/TA_, is driven by the addressed slave to acknowledge
the completion of a data transfer on the QBus
DSACK0_ has the same timing and characteristics as DSACK1_/TA_ (see the following description).
DSACK1_/TA_ Rescinding tristate bidirectional
Data and Size Acknowledge 1: Used in conjunction with DSACK0_. This signal is driven by the addressed slave to
acknowledge the completion of a data transfer on the QBus.
QSpan II terminates all normal bus cycles by asserting both DSACK1_/TA_ and DSACK0_ (indicating a 32-bit port
width at all times). The DSACK1_/TA_ output is driven high (inactive) after the release of AS_ until the next falling
edge of the clock, at which point it is tristated.
DS_ Rescinding tristate output
Data Strobe: used to indicate valid data on the data bus during write transactions, and to request data during read
transactions. DS_ is driven by the QSpan II when it is a QBus master, and is tristated otherwise.
As a slave the QSpan II assumes write data is valid on the rising edge of QCLK following the clock edge where AS_
is sampled asserted. For read transactions, the QSpan II provide information independent of DS_. DS_ is output only .
As a master on the QBus, the QSpan II asserts DS_ to qualify data during reads and writes. For write transactions,
the DS_ is driven from the falling edge of QCLK one half a clock period after the data is driven onto the Data bus.
For read transactions, DS is driven at the same time as AS_. QSpan II negates DS_ prior to tristate.
HALT_/TRETRY_ Rescinding tristate bidirectional
Halt: Suspends external bus activity. It is used for generating retries.
As an MC68360 slave QSpan II uses HALT_/TRETRY_ as stated in Ta ble 11 on page 52.
As an MC68360 master QSpan II uses HALT_/TRETRY_ as stated in Table 27 on page 79.
IMSEL Input
Image Select: selects which QBus Slave Image to use when CSPCI_ is asserted.
The timing requirements for IMSEL are the same as those of the address bus when the QSpan II is a QBus slave.
QCLK Input
QBus Clock: All devices intended to interface with QBus side of the QSpan II must be synchronized to this clock.
The QCLK can operate up to 33 MHz (with an MC68360 bus). During IDMA fast termination cycles the maximum
MC68360 QCLK frequency is 30 MHz.
16.3 MC68360 Signals: QUICC (Continued)
Chapter 16: Signals
QSpan II User Manual164 May 16, 20 13
QINT_ Open drain bidirectional
QBus Interrupt: as an output, this open drain signal is asserted by the QSpan II when an interrupt event occurs,. As
an input, this signal can be mapped to the PCI INT# output.
RESETI_ Input
QBus Reset Input: resets the QSpan II from the QBus side of the QSpan II. RESETI_ does not reset PCI
configuration and status registers.
RESETO_ Open drain output
QBus Reset Output: asserted whenever the QSpan II's PCI RST# input is asserted, or the internal software reset bit is
set.
R/W_ Tristate bidirectional
Read Wr ite: indicates the direction of the data transfer on the Data bus. High indicates a read transaction; low
indicates a write. It has the same timing as the Address bus.
As a master, the QSpan II drives R/W_, and tristates it otherwise. As a slave, the R/W_ pin is an input.
SIZ[1:0] Tristate bidirectional
Size: indicates the number of bytes to be transferred during a bus cycle. The value of the Size bits, along with the
lower two address bits and the port width, define the byte lanes that are active. Table 51 on page 169 shows the
encoding for the Size bits.
TC[3:0] Tristate bidirectional
T ransaction Code: provides additional information about a bus cycle when the QSpan II is a QBus master. Driven by
the QSpan II when it is a QBus master, and tristated otherwise.
As a slave, the QSpan II samples TC[3:0] on the first falling edge of the QCLK after AS_ is asserted. TC[3:0] can
optionally be used with DACK_/SDACK_ to decode an IDMA operation. For use in IDMA transfers, TC[3:0]
should be set to all ones.
The timing for the TC[3:0] outputs is the same as the timing for the address bus when the QSpan II is a QBus master.
The values output on the TC[3:0] bus during a transaction in which the QSpan II is the bus master is determined by
the value programmed in the Transaction Code field of the corresponding QSpan II PCI target image. TC[3:0] is
intended to connect to the MC68360’s FC[3:0], but may be used for other special decoding purposes.
16.3 MC68360 Signals: QUICC (Continued)
Chapter 16: Signals
QSpan II User Manual 165
May 16, 2013
16.4 MPC860 Signals: PowerQUICC
A[31:0] Trista te bidirectional
Address bus: address for the current bus cycle. It is driven by the QSpan II when it is the QBus master and input as
slave. It is qualified at the start of a transaction by TS_.
As a slave, the QSpan II samples A[31:0] on the rising edge of QCLK, and is qualified by Transaction Start (TS_) on
the same rising clock edge.
As a master, the address is driven out following a rising edge of the QCLK.
When accesses are made to QSpan II registers from the QBus, only the lower 12 bits of the address bus are used to
determine the register offset.
AT[0:3] Tristate bidirectional
See TC[3:0]
BB_/BGACK_ Rescinding tristate bidirectional
Bus Busy: indicates ownership of the QBus. BB_ is asserted low by a master to show that it owns the bus. BB_,
along with BR_ and BG_, provides the three-wire handshake for QBus arbitration.
As an output the QSpan II asserts BB_/BGACK_ from the rising edge of QCLK (while master). QSpan II drives
BB_/BGACK_ to the prior to tristate. Note in the MPC860 mode, the QSpan II asserts BB_ one clock after receiving
BG_: in compliance with the MPC860 arbiter.
As an input, the QSpan II samples BB_/BGACK_ on the rising edge of QCLK.
QSpan II can also be programmed to use a asynchronous mode for QBus arbitration.
BDIP_ Bidirectional
Burst Data In Progress: As MPC860 master , the QSpan II uses BDIP_ in burst writes to indicate the second last data
beat of a transaction. This allows the QSpan II to perform burst writes of two, three, or four beats. QSpan II does not
use BDIP_ in the same manner for burst reads. Burst reads are always cacheline aligned and four beats in length.
As MPC860 slave, the QSpan II monitors BDIP_ as a signal indicating the second last data beat in the burst. This
allows the QSpan II to support bursts of two, three, or four data beats.
The QBus master mode of the QSpan II is determined at power-up and reset by sensing the level of this pin. If BDIP_
is sampled as low (at reset) the QBus master module will operate as a MC68360 master . At reset, if the BDIP_ signal
is sampled as high the QSpan II will operate as an MPC860 or M68040 master (see Table 48 on page 156).
BERR_/TEA_ Rescinding tristate bidirectional
Transfer Error Acknowledge: indicates that a bus error occurred in the current transaction.
Driven by the QSpan II when it is a QBus slave, and tristated otherwise.
As an output BERR_/TEA_ is driven by the QSpan II from the rising edge of QCLK. QSpan II negates
BERR_/TEA_ prior to tristate.
As an input, the QSpan II samples BERR_/TEA_ on the rising edge of QCLK during cycles in which it is a QBus
master.
BG_ Input
Bus Grant: indicates that the QSpan II may become the next QBus master . BG_, along with BR_ and BB_/BGACK_,
provide the three-wire handshake for QBus arbitration. BG_ is sampled on the rising edge of QCLK.
QSpan II can be programmed to use a asynchronous mode for QBus arbitration.
Chapter 16: Signals
QSpan II User Manual166 May 16, 20 13
BR_ Output
Bus Request: used by the QSpan II to request ownership of the QBus. BR_, along with BG_ and BB_/BGACK_,
provide the three-wire handshake for QBus arbitration.
BR_ is asserted and released from the rising edge of QCLK.
BM_EN/
FIFO_RDY_ Bidirectional
Bus Master Enable: If this input is asserted — set as 1 — during a PCI Reset, the Bus Master Enable bit in the
PCI_CS register will be set.
(FIFO_RDY) FIFO Ready functionality is not relevant to MPC860 applications.
BURST_/TIP Tristate bidirectional
Burst: indicates that the current initiated transfer is a burst cycle. This signal matches the MPC860 signal of the same
name.
CSPCI_ Input
PCI Chip Select: indicates that the current transaction on the QBus is an access to the PCI Bus. CSPCI_ can be
sampled on the same clock as TS or up to three clocks following TS_ assertion. During IDMA cycles, if this is
sampled high, a single address transfer is indicated; otherwise, a dual address transfer is indicated.
CSREG_ Input
Register Chip Select: indicates that the current transaction on the QBus is an access to the QSpan II’s registers.
CSREG_ can be sampled on the same clock as TS_ or up to three clocks following TS_ assertion. This signal is
sampled synchronously on the rising edge of clock after TS_.
DP[3:0] Bidirectional
Data Parity: provides the parity information for the data on D[31:0]. It is valid on the same clock as the data.
D[31:0] Trista te bidirectional
Data Bus: provides the general-purpose data path between the QSpan II, the MPC860, and other devices.
DACK_/SDACK_ Input
IDMA Acknowledge: indicates to the QSpan II that the current transaction is an IDMA transaction.
DONE_ Input
IDMA Done: This signal is not used with MPC860 transfers.
DREQ_ Output
IDMA Request: request to the MPC860 IDMA to either transfer data to QSpan II IFIFO (PCI W rite) or remove data
from I-FIFO (PCI Read). It is asserted from the rising edge of QCLK in MPC860 mode.
16.4 MPC860 Signals: PowerQUICC (Continued)
Chapter 16: Signals
QSpan II User Manual 167
May 16, 2013
DSACK1_/TA_ Rescinding tristate bidirectional
Transaction Acknowledge: driven by the addressed slave to acknowledge the completion of a data transfer on the
QBus.
As a slave the QSpan II terminates all normal bus cycles by asserting TA_. QSpan II negates DSACK1_/TA_ prior to
tristate.
HALT_/TRETRY_ Rescinding tristate bidirectional
Transfer Retry: used for generating retries.
As a MPC860 slave, QSpan II uses HALT_/TRETRY_ as stated in Table 12 on page 52.
As a MPC860 master, QSpan II uses HALT_/TRETRY_ as stated in Table 28 on page 79.As a slave,
HALT_/TRETRY_ has the same timing as DSACK1_/TA_. QSpan II negates HALT_/TRETRY_ prior to tristate.
IMSEL Input
Image Select: selects which QBus Slave Image to use when CSPCI_ is asserted.
The timing requirements for IMSEL are the same as those of the address bus when the QSpan II is a QBus slave.
QCLK Input
QBus Clock: All devices intended to interface with QBus side of the QSpan II must be synchronized to this clock.
The maximum QCLK frequency with a MPC860 is 50 MHz.
QINT_ Open drain bidirectional
QBus Interrupt: as an output, this open drain signal is asserted by the QSpan II when an interrupt event occurs,. As
an input, this signal can be mapped to the PCI INT# output.
RESETI_ Input
QBus Reset Input: resets the QSpan II from the QBus side of the QSpan II. Note that RESETI_ does not reset PCI
configuration and status registers.
RESETO_ Open drain output
QBus Reset Output: asserted whenever the QSpan II's PCI RST# input is asserted, or the internal software reset bit is
set.
R/W_ Trista te bidirectional
Read Wr ite: indicates the direction of the data transfer on the Data bus. High indicates a read transaction; low
indicates a write. It has the same timing as the Address bus.
As an active master, the QSpan II drives R/W_, and tristates it otherwise.
As an addressed slave, the R/W_ pin is an input.
SIZ[1:0] Trista te bidirectional
Size: indicates the number of bytes to be transferred during a bus cycle. The value of the Size bits, along with the
lower two address bits and the port width, define the byte lanes that are active. Table 51 on page 169 shows the
encoding for the Size bits.
SIZ[1:0] is intended to connect to MPC860 TSIZ[0:1].
16.4 MPC860 Signals: PowerQUICC (Continued)
Chapter 16: Signals
QSpan II User Manual168 May 16, 20 13
The following table applies to MC68360 and MPC860 SIZ[1:0] signals.
TA_ Rescinding tristate bidirectional
See DSACK1_/TA_
TC[3:0] Tristate bidirectional
Transaction Code Bus: provides additional information about a bus cycle when the QSpan II is a QBus master.
Driven by the QSpan II when it is a QBus master, and tristated otherwise.
As a slave, the QSpan II samples TC[3:0] on the first rising edge of the QCLK after TS_ is asserted. TC[3:0] can
optionally be used with DACK_/SDACK_ to decode an IDMA operation. For use in IDMA transfers, TC[3:0]
should be set to all ones.
The timing for the TC[3:0] outputs is the same as the timing for the address bus when the QSpan II is a QBus master.
The values output on the TC[3:0] bus during a transaction in which the QSpan II is the bus master is determined by
the value programmed in the Transaction Code field of the corresponding QSpan II PCI target image. TC[3:0] is
intended to connect to the MPC860’s AT[0:3], but can be used for other special decod ing purposes.
TEA_ Rescinding tristate bidirectional
See BERR_/TEA_
TRETRY_ Rescinding tristate bidirectional
See HALT_/TRETRY_
TS_ Rescinding Tristate bidirectional
T ransfer Start: TS_ is a three state bi-directional signal used to indicate the beginning of an MPC860 bus transaction
on the QBus.
The TS_ output is driven by the QSpan II when the QSpan II is the QBus master, and is tri-stated at all other times.
As an output, TS_ is driven low after a rising edge of the QCLK. Transfer S tart indicates the following signals will
be valid on the next rising edge of the QCLK: A[31:0], TC[3:0], SIZ[1:0], and R/W_. QSpan II rescinds TS_ prior to
tri-state.
As an input, TS_ is sampled on the rising edge of the QCLK. QSpan II samples the address bus and other TS_
qualified signals on the same rising edge of QCLK in which it samples TS_ asserted. CSPCI_ and CSREG_ may
have up to three wait states after TS_ is sampled.
Table 51: MC68360/MPC860 Encoding for the SIZ[1:0] Signal
SIZ[1] SIZ[0] QSpan II
Master QSpan II
MC68360 slave QSpan II
MPC860 slave
0 0 4 bytes 4 bytes 4 bytes
0 1 1 byte 1 byte 1 byte
1 0 2 bytes 2 bytes 2 bytes
1 1 Reserved 3 bytes 3 bytes
16.4 MPC860 Signals: PowerQUICC (Continued)
Chapter 16: Signals
QSpan II User Manual 169
May 16, 2013
16.5 M68040 Signals
A[31:0] Tristate bidirectional
Address bus: Address for the current bus cycle. It is driven by the QSpan II when the QSpan II is the M68040 master
and input when the QSpan II is the slave. It is qualified at the start of a transaction by TS_.
As a slave, the QSpan II samples A[31:0] on the rising edge of QCLK, and is qualified by Transaction Start (TS_).
As a master, the address is driven out following a rising edge of the QCLK.
When accesses are made to QSpan II registers from the QBus, only the lower 12 bits of the address bus are used to
determine the register offset.
BB_/BGACK_ Rescinding tristate bidirectional
Bus Busy: This signal is asserted by the current bus master to indicate ownership of the M68040 bus. BB_, along
with BR_ and BG_, provide the three-wire handshake for M68040 bus arbitration.
As an output the QSpan II asserts BB_/BGACK_ from the rising edge of QCLK (while master). QSpan II negates
BB_/BGACK_ prior to tristate.
As an input, the QSpan II samples BB_/BGACK_ on the rising edge of QCLK (while master).
QSpan II can also be programmed to use an asynchronous mode for M68040 bus arbitration.
BDIP_ Bidirectional
Burst Data In Progress: This signal is only used in the 68040 mode at reset.
QSpan II Master/Slave mode is determined at reset by sensing the level of this pin in conjunction with SIZ[1]. See
Table 48 on page 156.
BERR_/TEA_ Rescinding tristate bidirectional
Transfer Error Acknowledge: indicates an error condition exists for a bus transfer.
Driven by the QSpan II when it is a M68040 bus slave to signal an errored transaction.
As an input, the QSpan II samples BERR_/TEA_ during M68040-style cycles in which it is a M68040 bus master on
the rising edge of QCLK.
Tar get retries are indicated by the simultaneous assertion of DSACK1_/TA_ and BERR_/TEA _.
BG_ Input
Bus Grant: indicates that the QSpan II may become the next M68040 bus master. BG_, along with BR_ and
BB_/BGACK_, provide the three-wire handshake for M68040 bus arbitration. BG_ is sampled on the rising edge of
QCLK.
QSpan II can be programmed to use an asynchronous mode for M68040 bus arbitration.
BM_EN/
FIFO_RDY_ Bidirectional
Bus Master Enable: If this input is asserted (set as 1) during a PCI Reset, the Bus Master Enable bit in the PCI_CS
register will be set.
BR_ Output
Bus Request: asserted by the QSpan II to request ownership of the M68040 bus. BR_, along with BG_ and
BB_/BGACK_, provide the three-wire handshake for M68040 bus arbitration.
BR_ is asserted and released from the rising edge of QCLK.
Chapter 16: Signals
QSpan II User Manual170 May 16, 20 13
BURST_/TIP_ Tristate bidirectional
T ransaction In Progress: asserted for the length of an M68040 transfer . This signal uses the same pin as the MPC860
BURST_ signal.
CSPCI_ Input
PCI Chip Select: indicates that the current transaction on the QBus is an access to the PCI Bus.
CSREG_ Input
Register Chip Select: indicates that the current transaction on the QBus is an access to the QSpan II’s registers.
D[31:0] Tristate bidirectional
Data Bus: provides the data information for the QSpan II’s inputs and outputs on the M68040 bus.
DSACK1_/TA_ Rescinding tristate bidirectional
Transaction Acknowledge: asserted by the addressed slave to acknowledge a bus transfer.
As a slave the QSpan II terminates all normal bus cycles by asserting DSACK1_/TA_. QSpan II negates
DSACK1_/TA_ prior to tristate.
Tar get retries are indicated by the simultaneous assertion of DSACK1_/TA_ and BERR_/TEA_.
IMSEL Input
Image Select: selects which QBus Slave Image to use when CSPCI_ is asserted.
The timing requirements for IMSEL are the same as those of the address bus when the QSpan II is a M68040 bus
slave.
QCLK Input
QBus Clock: All devices intended to interface with QBus side of the QSpan II must be synchronized to this clock.
QCLK can operate up to 40MHz.
QINT_ Open drain bidirectional
QBus Interrupt: as an output, this open drain signal is asserted by the QSpan II when an interrupt event occurs. As an
input, this signal can be mapped to the PCI INT# output.
RESETI_ Input
QBus Reset Input: resets the QSpan II from the QBus side of the QSpan II. RESETI_ does not reset PCI
configuration and status registers.
RESETO_ Open drain output
QBus Reset Output: asserted whenever the QSpan II's PCI RST# input is asserted, or the internal software reset bit is
set.
16.5 M68040 Signals (Continued)
Chapter 16: Signals
QSpan II User Manual 171
May 16, 2013
R/W_ Tristate bidirectional
Read Wr ite: indicates the direction of the data transfer on the Data bus. High indicates a read transaction; a low
indicates a write. It has the same timing as the Address bus.
As a master, the QSpan II drives R/W_, and tristates it otherwise.
As a slave, the R/W_ pin is an input.
SIZ[1:0] Tristate bidirectional
Size: indicates the number of bytes to be transferred during a bus cycle. The value of the Size bits, along with the
lower two address bits and the port width, define the byte lanes that are active. Table 52 on page 172 shows the
encoding for the Size bits. SIZ[1:1] indicates a M68040 burst cycle.
TA_ Rescinding tristate bidirectional
See DSACK1_/TA_
TC[3:0] Tristate bidirectional
T ransaction Code Bus: provides additional information about a bus cycle when the QSpan II is a M68040 bus master .
Driven by the QSpan II when it is a M68040 bus master.
As a slave, the QSpan II samples TC[3:0] on the rising edge of QCLK, and is qualified by Transfer S tart (TS_).
The timing for the TC[3:0] outputs is the same as the timing for the address bus when the QSpan II is a M68040 bus
master.
The values output on the TC[3:0] bus during a transaction in which the QSpan II is the bus master is determined by
the value programmed in the Transaction Code field of the corresponding PCI target image. TC[3:0] may be
connected to a subset of the TT[1:0] and TM[2:0] M68040 pins. Unused TC[3:0] pins, if any, should be connected to
pull-up resistors.
TEA_ Rescinding tristate bidirectional
See BERR_/TEA_
TIP_ Tristate bidirectional
See BURST_/TIP_
TS_ Tristate bidirectional
Transfer Start: asserted for one clock period to indicate the start of a transfer.
16.5 M68040 Signals (Continued)
Chapter 16: Signals
QSpan II User Manual172 May 16, 20 13
The following table describes the signal encoding for M68040 SIZ[1:0] signals. Byte
lane enabling is combined with A[1:0] as described in the Motorola M68040 Users
Manual.
Table 52: M68040 Encoding for the SIZ[1:0] Signal
SIZ[1] SIZ[0] QSpan II as
M68040 Master QSpan II as
M68040 Slave
0 0 4 bytes 4 bytes
0 1 1 byte 1 byte
1 0 2 bytes 2 bytes
1 1 Reserved Line (burst)
16.6 PCI Bus Signals
AD [31:0] Bidirectional (t/s)
PCI Address/Data Bus: address and data are multiplexed over these pins providing a 32-bit address/data bus. A bus
transaction consists of an address phases followed by one or more data phases.
C/BE# [3:0] Bidirectional (t/s)
PCI Bus Command and Byte Enable Lines: command information during address phase and byte line enables during
data phase.
DEVSEL# Bidirectional (s/t/s)
PCI Device Select: driven by the QSpan II when it is accessed as PCI slave. Sampled by the QSpan II when it is PCI
master.
EXT_GNT#[6:1] Output
External Grant: used by the QSpan II to indicate to an external device that it has been granted access to the PCI bus
(this is an output).
EXT_REQ#[6:1] Bidirectional
External Request: used by an external device to indicate to the QSpan II PCI bus arbiter that it wants ownership of
the PCI bus. The QSpan II drives the unused EXT_REQ#[6:1] pins high when an external arbiter is used.
FRAME# Bidirectional (s/t/s)
Cycle Frame for PCI Bus: driven by the QSpan II when it is PCI master , and is monitored by the QSpan II when it is
PCI target. This signal indicates the beginning and duration of an access.
Chapter 16: Signals
QSpan II User Manual 173
May 16, 2013
GNT# Bidirectional
PCI Grant: As an input, when the QSpan II uses an external arbiter, it indicates to the QSpan II that it has been
granted ownership of the PCI bus. GNT# can be parked at QSpan II to improve its PCI master performance.
As an output, when the QSpan II is the PCI bus arbiter, it indicates to an external device that it has been granted
access to the PCI bus.
IDSEL Input (in)
PCI Initialization Device Select: used as a chip select during configuration read and write transactions
INT# Bidirectional (o/d)
PCI Interrupt: As an output, it indicates that the QSpan II is generating an internal interrupt. As an input, this signal
will cause QINT# to be asserted on the QBus bus (if enabled).The signal can be used as an input for an application
where the MPC860 is the system host.
IRDY# Bidirectional (s/t/s)
Initiator Ready: used by the QSpan II to indicate that it is ready to complete the current data phase of the transaction.
As PCI target, the QSpan II monitors this signal during reads to determine when the PCI master is ready to accept
data.
PAR Bidirectional (t/s)
Parity: parity is even across AD [31:0] and C/BE# [3:0] (the number of 1s summed across these lines and PAR equal
an even number).
PCLK Input (in)
PCI Clock input for PCI interface used to generate fixed timing parameters. PCLK can operate up to 33MHz.
PERR# Bidirectional (s/t/s)
Parity Error: reports parity err o rs during all PCI trans actions except a special cycle. QSpan II asserts PERR# within
two clocks of receiving a parity error on incoming data, and holds PERR# for at least one clock for each errored data
phase.
REQ# Bidirectional (t/s)
Bus Request: used by the QSpan II to indicate that it requires the use of the PCI bus; this is an output when the
QSpan II uses an external arbiter. REQ# is also used by an external device to indicate to the QSpan II PCI bus arbiter
that this device wants use of the PCI bus; this signal is an input when the QSpan II PCI bus arbiter is used.
RST# Input
PCI Reset: Asynchronous Reset that is used to bring PCI-specific registers, state machines, and signals to a
consistent state.
SERR# Bidirectional
System Error: reports address parity errors during all transactions. QSpan II asserts SERR# within two clocks of
receiving a parity error on incoming address, and holds SERR# for at least one clock for each errored data phase.
16.6 PCI Bus Signals (Continued)
Chapter 16: Signals
QSpan II User Manual174 May 16, 20 13
STOP# Bidirectional
Stop: used by the QSpan II as PCI target when it wishes to signal the PCI master to stop the current transaction. As
PCI master, the QSpan II terminates the transaction if it receives STOP# from the PCI target.
TRDY# Bidirectional (s/t/s)
Target Ready: used by the QSpan II as PCI target to indicate that it is ready to complete the current data phase.
During a read with QSpan II as PCI master, the target asserts TRDY# to indicate to the QSpan II that valid data is
present on the data bus.
16.7 Hot Swap Signals
ENUM# Open Drain Output
Hot Swap Event Interrupt: notifies the PCI host that either a board has been inserted or is about to be extracted.
HS_HEALTHY_ Input
Hot Swap Healthy: QSpan II internally OR’s this input with PCI reset (RST#) to determine when back-end power is
stable.
HS_LED Output
Hot Swap LED Control: This signal is driven by QSpan II to control the status of the LED. The signal is driven low
to turn on the LED during the hardware and software connection stages. The signal is tri-stated during normal
operation to turn off the LED.
HS_SWITCH Input
Hot Swap Switch: QSpan II uses this input to monitor the state of the Hot Swap board ejector latch. A low value on
this signal indicates that the ejector latch is open.
16.6 PCI Bus Signals (Continued)
Chapter 16: Signals
QSpan II User Manual 175
May 16, 2013
16.8 Miscellaneous Signals
ENID Input
ENID: EEPROM Loading Reset Option. If ENID is sampled high after a PCI reset, then the QSpan II will download
register information from the EEPROM.
PCI_ARB_EN Input
PCI Arbiter Enable: If PCI_ARB_EN is sampled high at the negation of Reset, the QSpan II’s PCI bus arbiter is
enabled and will function as the PCI bus arbiter.
PCI_DIS Input
PCI Configuration Disable: This is a power -up option which makes the QSpan II hold off on ENUM# assertion and
retry PCI configuration cycles to allow the Host processor to perform local configuration. QSpan II accepts PCI
configuration cycles after the PCI_DIS bit is cleared in the MISC_CTL2 register.
PME# Open Drain Output
Power Management Event Interrupt: This signal is asserted to request a change in its current power management
state and/or to indicate that a power management event has occurred.
SCL Output
Serial Clock: EEPROM Serial clock. The frequency of the SCL is the PCLK frequency divided by 210.
SDA Bidirectional
Serial Data: EEPROM Serial data line. If SDA is sampled high after a PCI reset, then the QSpan II will download
register information from the EEPROM.
TEST1 Input
This is a manufacturing test input which should be left open. This pin has an internal pull-up resistor.
TEST2 Input
This is a manufacturing test input which should be left open. This pin has an internal pull-down resistor.
TEST3 Input
This is a manufacturing test input which should be left open. This pin has an internal pull-down resistor.
TMODE[1:0] Input
Te st Mode: Selects the QSpan II test mode. These pins have internal pull-down resistors.
VH Power
Highest I/O Voltage: VH is a power pin which must be connected to the highest voltage level that the QSpan II I/Os
will observe on either the QBus or the PCI bus.
Chapter 16: Signals
QSpan II User Manual176 May 16, 20 13
16.9 J TAG Signals
TMS Input
Te st Mode Select: Used to control the state of the Test Access Port controller
TDI Input
Te st Inp ut: Used (in conjunction with TCK) to shift data and instructions into the Test Access Port (TAP) in a serial
bit stream.
TDO Output
Test Output: Used (in conjunction with TCK) to shift data and instructions into the Test Access Port (TAP) in a serial
bit stream.
TRST_ Input
Test Reset: Used to force the Test Access Port (TAP) into a initialized state.
TCK Input
Test Clock: Used to clock state information and data into and out of the device during boundary scan.
QSpan II User Manual 177
May 16, 2013
Chapter 17: Signals and DC Characteristics
This chapter discusses QSpan II signals and DC characteristics. The following topics
are explained:
“Packaging and Voltage Level Support” on page 178
“Signals and DC Characteristics” on page 178
“Pinout” on page 190
17.1 Terminology
The following abbreviations are used in this chapter:
2S Two-state output
3S Tristate output
B Bidirectional
I Input
OOutput
OD Open Drain
PD Internal pull-down
PU Internal pull-up
TTL Input with TTL threshold
TTL PU Input with TTL threshold (the pull-up resistor is internal)
TTL Sch. TTL Schmitt trigger input
Chapter 17: Signals and DC Characteristics
QSpan II User Manual178 May 16, 20 13
17.2 Packaging and Voltage Level Support
QSpan II is available in two packages:
17 mm x 17 mm, 1.0 mm ball pitch, 256 PBGA
27 mm x 27 mm, 1.27 mm ball pitch, 256 PBGA
Both packages require a 3.3V power supply and provide 3.3V or 5V I/O signaling
characteristics on the PCI bus. Both devices are also 5V tolerant. For more information
on QSpan II packaging, see Appendix F: “Mechanical Information” on page 399.
17.3 Signals and DC Characteristics
Table 53: Non-PCI DC Electrical Characteristics (VDD ±5%)
Symbolsa
a. For more information on PCI signal characteristics, see the PCI Local Bus Specification (Revision 2.2).
Parameters Test conditions Min Max
VIH Voltage Input high TTL, TTL Sch 2.0V -
VIH Voltage Input high CMOS 0.7 VDD -
VIL Voltage Input low TTL, TTL Sch - 0.8V
VIL Voltage Input low CMOS - 0.3VDD
VHY Hysteresis for Schmitt TTL Sch 0.3V -
VOL Voltage Output low IOL = 8.0 mA
VDD = 3.0 V -0.4V
VOH Voltage Output high IOH = -8.0 ma
VDD = 3.0 V 2.4V -
IIL Input Leakage Current low With no pull-up or pull-down
resistance (VIN = VSS or VDD)-10.0A 10.0A
IIL_PU Input Leakage Current Low
with Pull-up - -100.0A-4A
IIH_PD Input Leakage Current
High with Pull-down -4A 100A
IOZ Tristate Output
Leakage VOUT = VDD or VSS -10.0A 10.0A
IDD Quiescent Supply Current VIN = VSS or VDD -80Ab
b. Depends on customer design.
CIN Input Capacitance - - 10pF
Chapter 17: Signals and DC Characteristics
QSpan II User Manual 179
May 16, 2013
Table 54: 3.3V PCI I/O Signaling AC/DC Characteristics (VDD ±5%)
Symbols Parameters Test Conditions Min Max Units
VIL Input low voltage - -0.5 0.3*VDD V
VIH Input high voltage - 0.5*VDD VDD+0.5 V
IIH Input high current 0<VIN<VDD -10 +10 A
IIL Input low current 0<VIN<VDD -10 +10 A
VOL Output low voltage IOL=1500 A - 0.1*VDD V
VOH Output high voltage IOH=-500 A 0.9*VDD -V
IOZ Output leakage current
tristate condition VOH=VSS or VDD -10 10 A
IOH (AC) Switching current high 0 <VOUT0.3VDD -12*VDD -mA
0.3VDD<VOUT<0.9VDD -17.1
(VDD-VOUT)-mA
0.7VDD<VOUT<VDD -Eqn AamA
(Test Point) VOUT=0.7VDD - -32VDD mA
IOL (AC) Switching current low VDD>VOUT>0.6VDD 16VDD -mA
0.6VDD>VOUT>0.1VDD 26.7VOUT -mA
0.18VDD>VOUT>0 - Eqn BbmA
(Test Point) VOUT=0.18VDD -38V
DD mA
ICL Low clamp current -3<VIN-1 -25+(VIN-VD
D-1)/0.015 -mA
ICH High clamp current VDD+4>VIN>VDD+1 25+(Vin-VDD
-1)/0.015 -mA
slewr Output rise slew rate 0.2VDD-0.6VDD load 1 4 V/ns
slewf Output fall slew rate 0.6VDD-0.2VDD load 1 4 V/ns
a. Equation A: IOH=(98.0/VDD)*(VOUT-VDD)*(VOUT+0.4VDD) for VDD >VOUT>0.7VDD
b. Equation B: IOL=(256/VDD) * VOUT * (VDD -VOUT) for 0v < VOUT<0.18VDD
Chapter 17: Signals and DC Characteristics
QSpan II User Manual180 May 16, 20 13
Table 55: 5V PCI I/O Signaling AC/DC Electrical Characteristics
Symbols Parameters Test Conditions Min Max Units
VIL Input low voltage - -0.5 0.8 V
VIH Input high voltage - 2.0 5.3aV
IIH Input high current V IN=2.7 - +70 A
IIL Input low current VIN=0.5 - -70 A
VOL Output low voltage IOL=3 mA, 6 mA - 0.55 V
VOH Output high voltage IOH=-2 mA 2.4 - V
IOZ Output leakage current
tristate condition VOH=VSS or VDD -70 70 A
IOH (AC) Switching current high 0<VOUT1.4 -44 - mA
1.4<VOUT<2.4 -44 + (VOUT
-1.4)/0.024 -mA
3.1<VOUT<VDD -Eqn CbmA
(Test Point) VOUT=3.1 - -142 mA
IOL (AC) Switching current low VOUT2.2 95 - mA
2.2>VOUT>0.55 VOUT/0.023 - mA
0.71>VOUT>0 - Eqn DcmA
(Test Point) VOUT=0.71 - 206 mA
ICL Low clamp current -5<VIN-1 -25 +
(VIN+1)/0.01
5
-mA
slewr Output rise slew rate 0.4 to 2.4 lo ad 1 5 V/ns
slewf Output fall slew rate 2.4 to 0.4 load 1 5 V/ns
a. All signals are 5V tolerant.
b. Equation C: IOH = 11.9 * (VOUT - 5.25) * (VOUT + 2.45) for VDD > VOUT > 3.1V
c. Equation D: IOL = 78.5 * VOUT * (4.4 - VOUT) for 0V < VOUT < 0.71V
Chapter 17: Signals and DC Characteristics
QSpan II User Manual 181
May 16, 2013
Table 56: Pin List for QSpan II Signals
Pin Name
17 mm
PBGA
Ball #
27 mm
PBGA
Ball # Type Input
Type Output
Type Reset
State IOL
(mA) IOH
(mA) Interface Signal Description
A[31:0] See
Table 58 See
Table 58 BTTL3SHi-Z8 -8QBus
Address Lines
AD[31:0] See
Table 57 See
Table 57 BPCI3SHi-Z- - PCI
Address/data Lines
AS_ L16 N20 B TTL
Sch. 3S Hi-Z 8 -8 QBus Address Strobe
BB_/BGACK_ L2 R1 B TTL
Sch. 3S Hi-Z 8 -8 QBus Bus Busy/bus Grant
Acknowledge
BDIP_ K14 M17 B TTL 3S Hi-Z 8 -8 QBus Burst Data In Progress
(And IDT QSpan II
Master Mode)
BERR_/TEA_ L15 N19 B TTL
Sch. 3S Hi-Z 8 -8 QBus Bus Error/ Transfer
Error Acknowledge
BG_ K16M18ITTL----QBus
Bus Grant
BGACK_ See BB_/BGACK_
BM_EN/
FIFO_RDY_ J14 M20 B TTL
(PD) 2S Hi-Z 8 -8 QBus Bus Master Enable
BR_ L1 R2 O TTL 2S Hi-Z 8 -8 QBus Bus Request
BURST_/TIP_ L4 N3 B TTL 3S Hi-Z 8 -8 QBus Burst/transaction In
Progress
C/BE[0] R11 W15
BPCI3SHi-Z
--
PCI
Command And Byte
Enables
C/BE[1] R9 W12
C/BE[2] N7 Y9
C/BE[3] T2 W4
CSPCI_P16R20ITTL----QBus
PCI Chip Select
CSREG_M13T19ITTL----QBus
QSpan Register Chip
Select
D[31:0] See
Table 59 See
Table 59 BTTL3SHi-Z8 -8QBus
Data Lines
DP[0] A5 C6
BTTL3SHi-Z8 -8QBus
Data Parity Line
DP[1] C5 B5
DP[2] B5 A4
DP[3] D4 C5
DACK_/
SDACK_ J13 K19 I TTL
Sch. ----QBus
IDMA Acknowledge
DEVSEL# R8 Y11 B PCI 3S Hi-Z 8 -8 PCI Device Select
Chapter 17: Signals and DC Characteristics
QSpan II User Manual182 May 16, 20 13
DONE_J15K17ITTL----QBus
IDMA Done
DREQ_ G13 J17 O TTL 3S Hi-Z 8 -8 QBus IDMA Request
DS_ C10 A13 O TTL 3S Hi-Z 8 -8 QBus Data Strobe
DSACK0_ G3 J4 B TTL
Sch. 3S Hi-Z 8 -8 QBus Data And Size
Acknowledge 0
DSACK1_/
TA_ F1 H1 B TTL
Sch. 3S Hi-Z 8 -8 QBus Data And Size
Acknowledge 1/
Transfer
Acknowledge
ENID H15 J18 I TTL
PD ---- -
EEPROM Loading
Reset Options
ENUM# G4 K1 O - OD Hi-Z 8 -8 - CompactPCI Hot
Swap event output
EXT_GNT#
[6:1] See
Table 60 See
Table 60 OPCI3SHi-Z- - PCI
External Grant
EXT_REQ#
[6:1] See
Table 60 See
Table 60 BPCI3SHi-Z- - PCI
External Request
FRAME# P7 W10 B PCI 3S Hi-Z - - PCI Cycle Frame
GNT# M3 U2 B PCI 3S Hi-Z - - PCI Grant (External Grant
7)
HALT_/
TRETRY_ M1 T1 B TTL
Sch. 3S Hi-Z 8 -8 QBus Halt/Transfer Retry
HS_
HEALTHY_ K4 N2 I TTL
(PD) ---- -
Hot Swap Healthy
Signal
HS_LED H2 L2 O - OD Low 8 -8 - LED control output
for Hot Swap
HS_SWITCH J2 L4 I TTL
(PD) ---- -
Switch input for
Hot Swap
IDSELN12Y16IPCI----PCI
Initialization Device
Select
IMSEL H4L1ITTL----QBus
Slave Image Select
INT# M14 T18 B PCI OD Hi-Z 8 -8 PCI Interrupt
IRDY# R7 V10 B PCI 3S Hi-Z - - PCI Initiator Ready
PAR N10 Y12 B PCI 3S Hi-Z - - PCI Parity
Table 56: Pin List for QSpan II Signals (Continu ed)
Pin Name
17 mm
PBGA
Ball #
27 mm
PBGA
Ball # Type Input
Type Output
Type Reset
State IOL
(mA) IOH
(mA) Interface Signal Description
Chapter 17: Signals and DC Characteristics
QSpan II User Manual 183
May 16, 2013
PCI_ARB_EN C4 B4 I TTL
(PD) ----PCI
Power up option to
enable PCI Bus
Arbiter
PCI_DIS K3 M4 I TTL
(PD) ----PCI
Power up option to
disable PCI config
accesses to QSpan II
PCLK P8W11IPCI----PCI
PCI Clock
PERR# N9 U11 B PCI 3S Hi-Z - - PCI Parity Error
PME# J1 M2 O - OD Hi-Z 8 -8 - Power management
event
QCLK D8A10ITTL----QBus
QBus clock
QINT_ H16 J19 B TTL OD Hi-Z 8 -8 QBus Interrupt
REQ# M4 T3 B PCI 3S Hi-Z - - PCI Request (Externa l
Request 7)
RESETI_ J4 M3 I TTL
Sch. ----QBus
Reset Input
RESETO_ K1 N1 O TTL OD Hi-Z 8 -8 QBus Reset Output
RETRY_ See HALT_/TRETRY_
RST# M2P4IPCI----PCI
Reset
R/W_ D1 G3 B TTL 3S Hi-Z 8 -8 QBus Read/Write
SCL H3 K3 O TTL 3S Hi-Z 8 -8 EEPRO
MSerial Clock
SDA G1 J1 B TTL OD Hi-Z 8 -8 EEPRO
MSerial Data
SDACK_ See DSACK_/SDACK_
SERR# M15 U20 B TTL OD Hi-Z 8 -8 PCI System Error
SIZ[0] G2 J2 BTTL3SHi-Z8 -8QBus
Size
SIZ[1] F4 J3
STOP# T7 V11 B PCI 3S Hi-Z - - PCI Stop
TA_ See DSACK1_/TA _
TC[0] N16 P18
BTTL3SHi-Z8 -8QBus
Transaction Code
TC[1] L14 P19
TC[2] M16 P20
TC[3] L13 N18
Table 56: Pin List for QSpan II Signals (Continued)
Pin Name
17 mm
PBGA
Ball #
27 mm
PBGA
Ball # Type Input
Type Output
Type Reset
State IOL
(mA) IOH
(mA) Interface Signal Description
Chapter 17: Signals and DC Characteristics
QSpan II User Manual184 May 16, 20 13
TCK H13 J20 I TTL - Hi-Z - - JTAG JTAG Test Clock
Input
TDI K15 L18 I TTL
(PU) -Hi-Z- - JTAG
JTAG Test Data Input
TDO K13 M19 O TTL 3S Hi-Z 8 -8 JTAG JTAG Test Data
Output
TEA_ See BERR_/TEA_
TEST1 B12 B15 I CMOS
(PU) ---- -
Manufacturing Test
Pin
TEST2 A14 D14 I TTL
(PD) ---- -
Manufacturing Test
Pin
TEST3 C12 C15 I TTL
(PD) ---- -
Manufacturing Test
Pin
TIP_ See BURST_/TIP_
TMODE[0] J3 M1 ITTL
(PD) ---- -
Test Mode Pins
TMODE[1] H1 L3
TMS J16 K20 I TTL
(PU) ----JTAG
JTAG Mode Select
TRDY# N8 Y10 B PCI 3S Hi-Z - - PCI Target Ready
TRST_ H14 K18 I TTL
(PU) ----JTAG
JTAG Test Reset
TS_ K2 P2 B TTL
Sch. 3S Hi-Z 8 -8 QBus Transfer Start
Table 56: Pin List for QSpan II Signals (Continu ed)
Pin Name
17 mm
PBGA
Ball #
27 mm
PBGA
Ball # Type Input
Type Output
Type Reset
State IOL
(mA) IOH
(mA) Interface Signal Description
Chapter 17: Signals and DC Characteristics
QSpan II User Manual 185
May 16, 2013
Table 57: PCI Bus Address/Data Pins
Signal 17 mm
PBGA 27 mm
PBGA Signal 17 mm
PBGA 27 mm
PBGA
AD0 N15 V20 AD16 P6 W9
AD1 N14 U18 AD17 T6 U9
AD2 T16 W20 AD18 T5 Y8
AD3 P15 V19 AD19 R6 W8
AD4 T14 Y20 AD20 N6 V8
AD5 T13 V18 AD21 P5 Y7
AD6 P14 W18 AD22 N5 V7
AD7 P12 U14 AD23 T1 U5
AD8 T10 V14 AD24 R2 W3
AD9 P11 Y15 AD25 R3 Y2
AD10 N11 W14 AD26 P3 Y1
AD11 P10 Y14 AD27 N3 W2
AD12 R10 V13 AD28 N4 W1
AD13 T9 W13 AD29 P2 U3
AD14 T8 Y13 AD30 P1 V2
AD15 P9 V12 AD31 N2 T4
Chapter 17: Signals and DC Characteristics
QSpan II User Manual186 May 16, 20 13
Table 58: QBus Address Pins
Signal 17 mm
PBGA 27 mm
PBGA Signal 17 mm
PBGA 27 mm
PBGA
A0 G14 G20 A16 A9 D10
A1 G16 G19 A17 D7 A9
A2 G15 F20 A18 B8 C9
A3 F14 F19 A19 C7 D9
A4 F16 E20 A20 A8 B8
A5 E16 G17 A21 A7 C8
A6 C13 C17 A22 B7 A7
A7 B16 B17 A23 D6 B7
A8 C14 A18 A24 C6 A6
A9 A15 B16 A25 A6 C7
A10 D12 C16 A26 C1 E3
A11 C11 C14 A27 E3 E1
A12 D11 B14 A28 E4 F2
A13 A13 A14 A29 E1 G2
A14 A12 C13 A30 F3 H3
A15 B11 B13 A31 F2 H2
Chapter 17: Signals and DC Characteristics
QSpan II User Manual 187
May 16, 2013
Table 59: QBus Data Pins
Signal 17 mm
PBGA 27 mm
PBGA Signal 17 mm
PBGA 27 mm
PBGA
D0 F15 F18 D16 C9 C11
D1 E15 E19 D17 A10 A11
D2 E14 E18 D18 B9 B10
D3 D16 E17 D19 C8 C10
D4 D15 C20 D20 B6 B6
D5 F13 D18 D21 D5 D7
D6 E13 B20 D22 A4 A3
D7 D14 B19 D23 A3 C4
D8 C16 C18 D24 B4 D5
D9 C15 A20 D25 A2 B3
D10 B14 B18 D26 B3 A2
D11 B15 A19 D27 C3 C2
D12 D10 D12 D28 B1 B1
D13 A11 C12 D29 D3 D3
D14 D9 B12 D30 D2 C1
D15 B10 B11 D31 C2 E4
Table 60: External Request and Grant Pins
Signal 17 mm
PBGA 27 mm
PBGA Signal 17 mm
PBGA 27 mm
PBGA
EXT_REQ[1]# T11 Y17 EXT_GNT[1]# R1 V5
EXT_REQ[2]# R12 V16 EXT_GNT[2]# R4 W5
EXT_REQ[3]# N13 W17 EXT_GNT[3]# T3 Y5
EXT_REQ[4]# P13 Y18 EXT_GNT[4]# P4 V6
EXT_REQ[5]# T12 U16 EXT_GNT[5]# R5 U7
EXT_REQ[6]# R13 V17 EXT_GNT[6]# T4 W6
Chapter 17: Signals and DC Characteristics
QSpan II User Manual188 May 16, 20 13
Table 61: Pin Assignments for Power (VDD)
17 mm PBGA 27 mm PBGA
A16aF12 M5 D2 D15 T2
B2aG5 M6 V3 F4 D20
E5 G12 M7 U12 F17 B2
E6 H5 M8 Y19 K4 R3a
E7 H12 M9 U19 L17 -
E8 J5 M10 G18 R4 -
E9 J12 M11 C19 R17 -
E10 K5 M12 D16 U6 -
E11 K12 N1aA5 U10 -
E12 L5 R15aD6 U15 -
F5 L12 -D11 E2 -
a. These power pins are called VH. These pins must be connected to the highest voltage level that the QSpan II I/Os
will observe on either the QBus or the PCI bus (see Table 62).
Table 62: Voltage Required to be Applied to VH
PCI Bus Voltage (V) QBus Voltage (V) VH Voltage (V)
3.3 3.3 3.3
555
3.3 5 5
53.35
VIOa3.3 VIOa
VIOa55
a. VIO denotes the signal connection to the PCI bus connector for Universal Signaling.
Chapter 17: Signals and DC Characteristics
QSpan II User Manual 189
May 16, 2013
Table 63: Pin Assignments for Ground (VSS)
17 mm PBGA 27 mm PBGA
F6 H6 K6 F1 A12 U8
F7 H7 K7 U1 A8 U13
F8 H8 K8 V1 A1 U17
F9 H9 K9 V9 D4 -
F10 H10 K10 H19 D8 -
F11 H11 K11 D19 D13 -
G6 J6 L6 D1 D17 -
G7 J7 L7 P3 H4 -
G8 J8 L8 W7 H17 -
G9 J9 L9 W19 N4 -
G10 J10 L10 T17 N17 -
G11 J11 L11 L20 U4 -
Table 64: No-connect Pin Assignmentsa
17 mm PBGA 27 mm PBGA
A1 A15 H18 T20
B13 A16 H20 V4
D13 A17 K2 V15
E2 B9 L19 W16
L3 C3 P1 Y3
R14 F3 P17 Y4
R16 G1 R18 Y6
T15 G4 R19 -
a. Route all N/C signals out to vias on your board to allow for future migration
to new QSpan II variants.
Chapter 17: Signals and DC Characteristics
QSpan II User Manual190 May 16, 20 13
17.4 Pinout
Table 65: Pinout of 17x17 mm Package
A1. N/C D5. D[21] G9. VSS K13. TDO P1. AD[30]
A2. D[25] D6. A[23] G10. VSS K14. BDIP_ P2. AD[29]
A3. D[23] D7. A[17] G11. VSS K15. TDI P3. AD[26]
A4. D[22] D8. QCLK G12. VDD K16. BG_ P4. EXT_GNT[4]#
A5. DP[0] D9. D[14] G13. DREQ_ L1. BR_ P5. AD[21]
A6. A[25] D10. D[12] G14. A[0] L2. BB_/BGACK_ P6. AD[16]
A7. A[21] D11. A[12] G15. A[2] L3. N/C P7. FRAME#
A8. A[20] D12. A[10] G16. A[1] L4. BURST_/TIP_ P8. PCLK
A9. A[16] D13. N/C H1. TMODE[1] L5. VDD P9. AD[15]
A10. D[17] D14. D[7] H2. HS_LED L6. VSS P10. AD[11]
A1 1. D[13] D15. D[4] H3. SCL L7. VSS P11. AD[9]
A12. A[14] D16. D[3] H4. IMSEL L8. VSS P12. AD[7]
A13. A[13] E1. A[29] H5. VDD L9. VSS P13. EXT_REQ[4]#
A14. TEST2 E2. N/C H6. VSS L10. VSS P14. AD[6]
A15. A[9] E3. A[27] H7. VSS L11. VSS P15. AD[3]
A16. VH E4. A[28] H8. VSS L12. VDD P16. CSPCI_
B1. D[28] E5. VDD H9. VSS L13. TC3 R1. EXT_GNT[1]#
B2. VH E6. VDD H10. VSS L14. TC1 R2. AD[24]
B3. D[26] E7. VDD H11. VSS L15. BERR_/TEA_ R3. AD[25]
B4. D[24] E8. VDD H12. VDD L16. AS_ R4. EXT_GNT[2]#
B5. DP[2] E9. VDD H13. TCK M1. HALT_/TRETRY_ R5. EXT_GNT[5]#
B6. D[20] E10. VDD H14. TRST_ M2. RST# R6. AD[19]
B7. A[22] E11. VDD H15. ENID M3. GNT# R7. IRDY#
B8. A[18] E12. VDD H16. QINT_ M4. REQ# R8. DEVSEL#
B9. D[18] E13. D[6] J1. PME# M5. VDD R9. CBE[1]
B10. D[15] E14. D[2] J2. HS_SWITCH M6. VDD R10. AD[12]
B11. A[15] E15. D[1] J3. TMODE[0] M7. VDD R11. CBE[0]
B12. TEST1 E16. A[5] J4. RESETI_ M8. VDD R12. EXT_REQ[2]#
B13. N/C F1. DSACK1_/TA_ J5. VDD M9. VDD R13. EXT_REQ[6]#
B14. D[10] F2. A[31] J6. VSS M10. VDD R14. N/C
B15. D[11] F3. A[30] J7. VSS M11. VDD R15. VH
B16. A[7] F4. SIZ[1] J8. VSS M12. VDD R16. N/C
C1. A[26] F5. VDD J9. VSS M13. CSREG_ T1. AD[23]
C2. D[31] F6. VSS J10. VSS M14. INT# T2. CBE[3]
C3. D[27] F7. VSS J11. VSS M15. SERR# T3. EXT_GNT[3]#
C4. PCI_ARB_EN F8. VSS J12. VDD M 16 . TC[2 ] T4. EXT_GNT[6]#
C5. DP[1] F9. VSS J13. DACK_/SDACK_ N1. VH T5. AD[18]
C6. A[24] F10. VSS J14. BM_EN/FIFO_RDY_ N2. AD[31] T6. AD[17]
C7. A[19] F11. VSS J15. DONE_ N3. AD[27] T7. STOP#
C8. D[19] F12. VDD J16. TMS N4. AD[28] T8. AD[14]
C9. D[16] F13. D[5] K1. RESETO_ N5. AD[22] T9. AD[13]
C10. DS_ F14. A[3] K2. TS_ N6. AD[20] T10. AD[8]
C11. A[11] F15. D[0] K3. PCI_DIS N7. CBE[2] T 11. EXT_REQ[1]#
C12. TEST3 F16. A[4] K4. HS_HEALTHY_ N8. TRDY# T12. EXT_RE Q[5 ]#
C13. A[6] G1. SDA K5. VDD N9. PERR# T13. AD[5]
C14. A[8] G2. SIZ[0] K6. VSS N10. PAR T14. AD[4]
C15. D[9] G3. DSACK0_ K7. VSS N11. AD[10] T15. N/C
C16. D[8] G4. ENUM# K8. VSS N12. IDSEL T16. AD[2]
D1. R/W_ G5. VDD K9. VSS N13. EXT_REQ[3]#
D2. D[30] G6. VSS K10. VSS N14. AD[1]
D3. D[29] G7. VSS K11. VSS N15. AD[0]
D4. DP[3] G8. VSS K12. VDD N16. TC[0]
Chapter 17: Signals and DC Characteristics
QSpan II User Manual 191
May 16, 2013
Table 66: Pinout of 27x27 mm Package
A1. VSS C13. A[14] H1. DSACK1_/TA_ P17 . N/C V13. AD[12]
A2. D[26] C14. A[11] H2. A[31] P18. TC[0] V14. AD[8]
A3. D[22] C15. TEST3 H3. A[30] P19. TC[1] V15. N/C
A4. DP[2] C16. A[10] H4. VSS P20. TC[2] V16. EXT_REQ[2]#
A5. VDD C17. A[6] H17. VSS R1. BB_/BGACK_ V17. EXT_REQ[6]#
A6. A[24] C18. D[8] H18. N/C R2. BR_ V18. AD[5]
A7. A[22] C19. VDD H19. VSS R3. VH V19. AD[3]
A8. VSS C20. D[4] H20. N/C R4. VDD V20. AD[0]
A9. A[17] D1. VSS J1. SDA R17. VDD W1. AD[28]
A10. QCLK D2. VDD J2. SIZ[0] R18. N/C W2. AD[27]
A1 1. D[17] D3. D[29] J3. SIZ[1] R19. N/C W3. AD[24]
A12. VSS D4. VSS J4. DSACK0_ R20. CSPCI_ W4. CBE[3]
A13. DS_ D5. D[24] J17. DREQ_ T1. HALT_/TRETRY_ W5. EXT_GNT[2]#
A14. A[13] D6. VDD J18. ENID T2. VDD W6. EXT_GNT[6]#
A15. N/C D7. D[21] J19. QINT_ T3. REQ# W7. VSS
A16. N/C D8. VSS J20. TCK T4. AD[31] W8. AD[19]
A17. N/C D9. A[19] K1. ENUM# T17. VSS W9. AD[16]
A18. A[8] D10. A[16] K2. N/C T18. INT# W10. FRAME#
A19. D[11] D11. VDD K3. SCL T19. CSREG_ W11. PCLK
A20. D[9] D12. D[12] K4. VDD T20. N/C W12. CBE[1]
B1. D[28] D13. VSS K17. DONE_ U1. VSS W13. AD[13]
B2. VDD D14. TEST2 K18. TRST_ U2. GNT# W14. AD[10]
B3. D[25] D15. VDD K19. DACK_/SDACK_ U3. AD[29] W15. CBE[0]
B4. PCI_ARB_EN D16. VDD K20. TMS U4. VSS W16. N/C
B5. DP[1] D17. VSS L 1. IMSEL U5. AD[23] W17. EXT_REQ[3]#
B6. D[20] D18. D[5] L2. HS_LED U6. VDD W18. AD[6]
B7. A[23] D19. VSS L3. TMODE[1] U7. EXT_GNT[5]# W19. VSS
B8. A[20] D20. VDD L4. HS_SWITCH U8. VSS W20. AD[2]
B9. N/C E1. A[27] L17. VDD U9. AD[17] Y1. AD[26]
B10. D[18] E2. VDD L18. TDI U10. VDD Y2. AD[25]
B11. D[15] E3. A[26] L19. N/C U11. PERR# Y3. N/C
B12. D[14] E4. D[31] L20. VSS U12. VDD Y4. N/C
B13. A[15] E17. D[3] M1. TMODE[0] U13. VSS Y5. EXT_GNT[3]#
B14. A[12] E18. D[2] M2. PME# U14. AD[7] Y6. N/C
B15. TEST1 E19. D[1] M3. RESETI_ U15. VDD Y7. AD[21]
B16. A[9] E20. A[4] M4. PCI_DIS U16. EXT_REQ[5]# Y8. AD[18]
B17. A[7] F1. VSS M17. BDIP_ U17. VSS Y9. CBE[2]
B18. D[10] F2. A[28] M18. BG_ U18. AD[1] Y10. TRDY#
B19. D[7] F3. N/C M19. TDO U19. VDD Y11. DEVSEL#
B20. D[6] F4. VDD M20.BM_EN/FIFO_RDY U20. SERR# Y12. PAR
C1. D[30] F17. VDD N1. RESETO_ V1. VSS Y13. AD[14]
C2. D[27] F18. D[0] N2.HS_HEALTHY_ V2. AD[30] Y14. AD[11]
C3. N/C F19. A[3] N3. BURST_/TIP_ V3. VDD Y15. AD[9]
C4. D[23] F20. A[2] N4. VSS V4. N/C Y16. IDSEL
C5. DP[3] G1. N/C N17. VSS V5. EXT_GNT[1]# Y17. EXT_REQ[1]#
C6. DP[0] G2. A[29] N18. TC[3] V6. EXT_GNT[4]# Y18. EXT_REQ[4]#
C7. A[25] G3. R/W_ N19. BERR_/TEA_ V7. AD[22] Y19. VDD
C8. A[21] G4. N/C N20. AS_ V8. AD[20] Y20. AD[4]
C9. A[18] G17. A[5] P1. N/C V9. VSS
C10. D[19] G18. VDD P2. TS_ V10. IRDY#
C11. D[16] G19. A[1] P3. VSS V11. STOP#
C12. D[13] G20. A[0] P4. RST# V12. AD[15]
Chapter 17: Signals and DC Characteristics
QSpan II User Manual192 May 16, 20 13
QSpan II User Manual 193
May 16, 2013
Appendix A: Registers
This Appendix describes the QSpan II’s registers . The following topics are discusse d:
“Register Map” on page 195
“Registers” on page 200
A.1 Overview
The 4 Kbytes of QSpan II Control and Status Registers (QCSRs) promotes ho st sy stem
configuration and allows the user to control QSpan II operational characteristics. The
QCSRs are divided into two functional groups: the PCI Configuration Registers and the
QSpan II Device Specific Registers. All of the QCSR space is accessible from both the
PCI bus and the QBus.
The QSpan II (CA91C862A) is backwards software compatible with the
QSpan (CA91C860B, CA91L860B). However, some register dif ferences
will be experienced (for example, device ID changes from one version to
the other).
Appendix A: Registers
QSpan II User Manual194 May 16, 20 13
A.2 Terminology
G_RST General reset. Active when either RST# or RESETI_ is driven
low or HS_HEALTHY_ is driven high.
N/A Not applicable
PCI_RST PCI Reset driven low (RST#) or HS_HEALTHY_ driven high.
0x Hexadecimal prefix (binary numbers have no prefix)
R Read Only. Writes have no effect.
R/W Read/Write from PCI or QBus.
R/W/E Read/W rite from PCI or QBus. Loadable from EEPROM after
PCI_RST.
R/WQ Read/Write from QBus only.
R/WP Read/Write from PCI only.
R/WQ/E Read/Write from QBus only. Loadable from EEPROM after
PCI_RST.
The bit combinations listed as “Reserved” must not be set to 1. All bits
listed as “Reserved” must read back a value of 0.
Appendix A: Registers
QSpan II User Manual 195
May 16, 2013
A.3 Register Map
Table 67: Register Map
Address Offset
(Hexidecimal) Register Description See
0x000 PCI_ID PCI Configuration Space ID Register Table 69 on
page 200
0x004 PCI_CS PCI Configuration Space Control and Status Register Table 70 on
page 201
0x008 PCI_CLASS PCI Configuration Class Register Table 71 on
page 204
0x00C PCI_MISC0 PCI Configuration Miscellaneous 0 Register Table 72 on
page 205
0x010 PCI_BSM/
I20_BAR PCI Configuration Base Address for Memory Register / I20
Base Address Register (when I20 operation is enabled) Table 73 on
page 206
0x014 PCI Unimplemented -
0x018 PCI_BST0/
PCI_BSM PCI Configuration Base Address for Target 0 Register/PCI
Configuration Base Address for Memory Register (when
I20 operation is enabled)
Table 75 on
page 208
0x01C PCI_BST1 PCI Configuration Base Address for Target 1 Register Table 77 on
page 210
0x020 PCI Unimplemented -
0x024 PCI Unimplemented -
0x02C PCI_SID PCI Configuration Subsystem ID Register Table 79 on
page 212
0x030 PCI_BSROM PCI Configuration Expansion ROM Base Address Register Table 80 on
page 213
0x034 PCI_CP PCI Capabilities Pointer Register Table 82 on
page 215
0x038 PCI Reserved -
0x03C PCI_MISC1 PCI Configuration Miscellaneous 1 Register Table 83 on
page 216
0x040–0x0DB PCI Unimplemented -
0x0DC PCI_PMC PCI Power Management Capabilities Register Table 84 on
page 217
0x0E0 PCI_PMCS PCI Power Management Control and Status Register Table 85 on
page 218
0x0E4 CPCI_HS CompactPCI Hot Swap Register Table 86 on
page 219
Appendix A: Registers
QSpan II User Manual196 May 16, 20 13
0x0E8 PCI_VPD PCI Vital Product Data (VPD) Register Table 88 on
page 221
0x0EC VPD_DATA PCI VPD Data Register Table 88 on
page 221
0x0F0–0x0FF PCI Unimplemented -
0x100 PBTI0_CTL PCI Bus Target Image 0 Control Register Table 89 on
page 222
0x104 PBTI0_ADD PCI Bus Target Image 0 Address Register Table 90 on
page 224
0x108–10F Reserved -
0x110 PBTI1_CTL PCI Bus Target Image 1 Control Register Table 92 on
page 226
0x114 PBTI1_ADD PCI Bus Target Image 1 Address Register Ta ble 93 on
page 228
0x118–0x13B Reserved -
0x13C PBROM_CTL PCI Bus Expansion ROM Control Register Table 95 on
page 230
0x140 PB_ERRCS PCI Bus Error Control and Status Register Table 9 7 on
page 232
0x144 PB_AERR PCI Bus Address Error Log Register Table 98 on
page 234
0x148 PB_DERR PCI Bus Data Error Log Register Table 99 on
page 235
0x14C–1FF Reserved -
0x200 I20_CS I20 Control and Status Register Table 100 on
page 236
0x204 IIF_TP I20 Inbound Free_List Top Pointer Register Table 101 on
page 238
0x208 IIF_BP I20 Inbound Free_List Bottom Pointer Register Table 102 on
page 239
0x20C IIP_TP I20 Inbound Post_List Top Pointer Register Table 103 on
page 240
0x210 IIP_BP I20 Inbound Post_List Bottom Pointer Register Table 104 on
page 241
0x214 IOF_TP I20 Outbound Free_List Top Pointer Register Table 105 on
page 242
Table 67: Register Map (Conti nu ed )
Address Offset
(Hexidecimal) Register Description See
Appendix A: Registers
QSpan II User Manual 197
May 16, 2013
0x218 IOF_BP I20 Outbound Free_List Bottom Pointer Register Table 106 on
page 243
0x21C IOP_TP I20 Outbound Post_List Top Pointer Register Table 107 on
page 244
0x220 IOP_BP I20 Outbound Post_List Bottom Pointer Register Table 108 on
page 245
0x224–3FF Reserved -
0x400 IDMA/DMA_CS IDMA/DMA Control and Status Register Table 109 on
page 246
0x404 IDMA/DMA_PADD IDMA/DMA PCI Address Register Table 110 on
page 249
0x408 IDMA/DMA_CNT IDMA/DMA Transfer Count Register Table 111 on
page 250
0x40C DMA_QADD DMA QBus Address Register Table 112 on
page 251
0x410 DMA_CS DMA Control and Status Register Table 113 on
page 252
0x414 DMA_CPP DMA Command Packet Pointer Register Table 114 on
page 255
0x418–0x4FF Reserved -
0x500 CON_ADD Configuration Address Register Table 115 on
page 256
0x504 CON_DATA Configuration Data Register Table 117 on
page 258
0x508 IACK_GEN IACK Cycle Generator Register Table 118 on
page 259
0x50C–0x5FF Reserved -
0x600 INT_STAT Interrupt Status Register Table 119 on
page 260
0x604 INT_CTL Interrupt Control Register Table 120 on
page 263
0x608 INT_DIR Interrupt Direction Control Register Table 121 on
page 266
0x60C INT_CTL2 Interru pt Control Register 2 Table 122 on
page 269
0x610–0x6FF Reserved -
Table 67: Register Map (Continued)
Address Offset
(Hexidecimal) Register Description See
Appendix A: Registers
QSpan II User Manual198 May 16, 20 13
0x700 MBOX0 Mailbox 0 Register Table 123 on
page 270
0x704 MBOX1 Mailbox 1 Register Table 124 on
page 271
0x708 MBOX2 Mailbox 2 Register Table 125 on
page 272
0x70C MBOX3 Mailbox 3 Register Table 126 on
page 273
0x710–0x7FF Reserved -
0x800 MISC_CTL Miscellaneous Control and Status Register Table 127 on
page 274
0x804 EEPROM_CS EEPROM Control and Status Register Table 129 on
page 277
0x808 MISC_CTL2Miscellaneous Control 2 Register Table 130 on
page 278
0x810 PARB_CTL PCI Bus Arbiter Control Register Table 131 on
page 281
0x814–0xEFF Reserved -
0xF00 QBSI0_CTL QBus Slave Image 0 Control Register Table 133 on
page 283
0xF04 QBSI0_AT QBus Slave Image 0 Address Translation Register Ta ble 138 on
page 285
0xF08–0xF0F Reserved -
0xF10 QBSI1_CTL QBus Slave Image 1 Control Register Table 140 on
page 287
0xF14 QBSI1_AT QBus Slave Image 1 Address Translation Register Ta ble 145 on
page 289
0xF18–0xF7F Reserved -
0xF80 QB_ERRCS QBus Error Log Control and Status Register Table 147 on
page 291
0xF84 QB_AERR QBus Address Error Log Register Table 148 on
page 292
0xF88 QB_DERR QBus Data Error Log Register Table 149 on
page 293
0xF8C–0xFFF Reserved -
Table 67: Register Map (Conti nu ed )
Address Offset
(Hexidecimal) Register Description See
Appendix A: Registers
QSpan II User Manual 199
May 16, 2013
Table 68: I2O Memory Map — Lower 4K
Address Offset Register Description Page
0x000–0x02F Reserved -
0x030 I2O_OPIS I20 Outbound Post_List Interrupt Status Register Table 150 on
page 294
0x034 I2O_OPIM I20 Outbound Post_List Interrupt Mask Register Table 151 on
page 295
0x038–0x03C Reserved -
0x040 I2O_INQ I20 Inbound Queue Register Table 152 on
page 296
0x044 I2O_OUTQ I20 Outbound Queue Register Table 153 on
page 297
0x048–0xFFF Reserved -
Appendix A: Registers
QSpan II User Manual200 May 16, 20 13
A.4 Registers
Table 69: PCI Configuration Space ID Register
Register Name: PCI_ID Register Offset: 000
Bits Function
31–24 DID
23–16 DID
15–08 VID
07–00 VID
PCI_ID Description
Name Type Reset By Reset
State Function
DID[15:0] R/WQ/E G_RST 0x0862 Device ID
IDT allocated Device Identifier.
VID[15:0] R/WQ/E G_RST 0x10E3 Vendor ID
PCI SIG allocated vendor Identifier for Tundra.
Note: IDT acquired Tundra Semiconductor.
Appendix A: Registers
QSpan II User Manual 201
May 16, 2013
Table 70: PCI Configuration Space Control and Status Register
Register Name: PCI_CS Register Offset: 004
Bits Function
31–24 D_PE S_SERR R_MA R_TA S_TA DEVSEL MD_PED
23–16 TFBBC Reserved DEV66 CAP_L PCI Reserved
15–08 PCI Reserved MFFBC SERR_EN
07–00 WAIT PERESP VGAPS MWI_EN SC BM MS IOS
PCI_CS Description
Name Type Reset By Reset
State Function
D_PE R/Write 1
to Clear PCI_RST 0 Detected Parity Error
0 = No parity error
1 = Parity error
This bit is set by the QSpan II whenever: the PCI Master
Module detects a data parity error, or the PCI Target
Module detects address or data parity errors.
S_SERR R/W rite 1
to Clear PCI_RST 0 Signaled SERR#
0 = SERR# not asserted
1 = SERR# asserted
The QSpan II as PCI target sets this bit when it asserts
SERR# to signal an address parity error. SERR_EN must
be set before SERR# can be asserted.
R_MA R/Write 1
to Clear PCI_RST 0 Received Master-Abort
0 = QSpan II did not generate Master-Abort
1 = QSpan II generated Master-Abort
The QSpan II sets this bit when a transaction it initiated
had to be terminated with a Master-Abort.
R_T A R/Write 1
to Clear PCI_RST 0 Received Target-Abort
0 = Master did not detect Target-Abort
1 = Master detected Target-Abort
The QSpan II sets this bit when a transaction it initiated
was terminated with a Target-Abort.
S_T A R/Write 1
to Clear PCI_RST 0 Signaled Target-Abort
0 = Ta rget did not terminate transaction with Target-Abort
1 = Ta rget terminated transaction with Ta rget-Abort
DEVSEL[1:0] R N/A 01 Device Select
Device Select Timing
The QSpan II is a medium-speed device.
Appendix A: Registers
QSpan II User Manual202 May 16, 20 13
MD_PED R/Write 1
to Clear PCI_RST 0 Master Data Parity Error Detected
0 = Master Module did not detect/generate data parity
error
1 = Master Module detected/generated data parity error
The QSpan II sets this bit if the PERESP bit is set and
either (a) it is the master of transaction in which it asserts
PERR#, or (b) the addressed target asserts PERR#.
TFBBC R N/A 1 Target Fast Back-to-Back Capable
QSpan II can accept fast back-to-back transactions from
different agents.
DEV66 R N/A 0 De vice 66 MHz Capable
The QSpan II is not capable of running at 66 MHz: it is a
33 MHz capable device.
CAP_L R N/A 1 Capabilities List
The QSpan II implements the new Capabilities List. The
capabilities pointer at offset 34h is a pointer to a linked list
of new capabilities.
MFBBC R N/A 0 Master Fast Back-to-Back Enable
QSpan II does not generate fast back-to-back transfers.
SERR_EN R/W PCI_RST 0 SERR# Enable
0 = Disable SERR# driver
1 = Enable SERR# driver
Setting this and PERESP allows the QSpan II to report
address parity errors with SERR# as PCI target.
WAIT R N/A 0 Wait Cycle Control
0 = No address/data stepping
PERESP R/W PCI_RST 0 Parity Error Response
0 = Disable
1 = Enable
Controls the QSpan II response to data and address parity
errors. When enabled, PERR# is asserted and the
MD_PED bit is set in response to data parity errors. When
this bit and SERR_EN are set, the
QSpan II reports address parity errors on SERR#. QSpan
II parity generation (for example., its assertion of PAR#) is
unaffected by this bit.
VGAPS R N/A 0 VGA Palette Snoop
0 = Disable
1 = Enable
PCI_CS Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual 203
May 16, 2013
The following status bits can generate an external interrupt: D_PE, S_SERR, R_MA,
R_TA, S_TA, and MD_PED (for more information, see “Interrupt Generation due to
PCI Configuration Register Status Bits” on page 118).
MWI_EN R PCI_RST 0 M emory Write and Invalidate Enable
0 = Disable
1 = Enable
The QSpan II generates Memory Write and Invalidate
command as PCI master during IDMA/DMA transfers
(CMD bit set in IDMA/DMA_CS).
SC R N/A 0 Spe cial Cycles
0 = Disable
1 = Enable
The QSpan II never responds to special cycles as PCI
target.
BM R/W PCI_RST Powerup
Option Bus Master
0 = Disable
1 = Enable
Enables the QSpan II to become PCI bus master.
This can be set as a reset option.
MS R/W PCI_RST 0 Memory Space
0 = Disable
1 = Enable
Enables the QSpan II target to accept Memory space
accesses.
IOS R/W PCI_RST 0 IO Space
0 = Disable
1 = Enable
Enables the QSpan II target to accept I/O space accesses.
PCI_CS Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual204 May 16, 20 13
Table 71: PCI Configuration Class Register
Register Name: PCI_CLASS Register Offset: 008
Bits Function
31–24 BASE
23–16 SUB
15–08 PROG
07–00 RID
PCI_CLASS Description
Name Type Reset By Reset
State Function
BASE[7:0] R/WQ/E PCI_RST 0x06 Base Class Code.
06 - Bridge Device
0Eh = I20 Controller
SUB[7:0] R/WQ/E PCI_RST 0x80 Sub Class Code.
80 - Other Bridge Device (if BASE = 06),
00 - I20 device (if BASE = 0E)
PROG[7:0] R/WQ/E PCI_RST 0x00 Programming Interface.
00 = Other Bridge Device (if BASE = 06),
00 = I20 Inbound and Outbound FIFOs at 40h and 44h (if
BASE = 0E),
01 = I20 Inbound and Outbound FIFOs at 40h and 44h, and
Interrupt Status and Mask registers at 30h and 34h (if BASE =
0E)
RID[7:0] R PCI_RST See
Right Revision ID
0x00 = QSpan II Prototype
0x01 = QSpan II Production Part
Appendix A: Registers
QSpan II User Manual 205
May 16, 2013
The latency timer supports an increment of two PCI bus clocks. The minimum value is
eight PCI bus clocks. The default value corresponds to eight PCI clock cycles.
CLINE[1:0] determines how the PCI Target module accepts burst write data (see
“Acceptance of Burst W rites by the PCI Target Module” on page 72). It also determines
how the IDMA/DMA Channel sinks data on and sources data from the PCI bus. If
CLINE[1:0] is set to 00, the QSpan II treats it as if it were set to 01.
Table 72: PCI Configuration Miscellaneous 0 Register
Register Name: PCI_MISC0 Register Offset: 00C
Bits Function
31–24 BISTC SBIST PCI Reserved CCODE
23–16 MFUNCT LAYOUT
15–08 LTIMER 0
07–00 0 0 0 0 CLINE 0 0
PCI_MISC0 Description
Name Type Reset By Reset
State Function
BISTC R N/A 0 BIST Capable
0 = Device not BIST capable
SBIST R N/A 0 Start BIST
0 = Device not BIST capable
CCODE[3:0] R N/A 0 Completion Code
0 = Device not BIST capable
MFUNCT R N/A 0 Multifunction Device
0 = QSpan II is not a multi-function Device
LAYOUT[6:0] R N/A 0 Configuration Space Layout
LTIMER[7:1] R/W PCI_RST 0 Latency Timer
Number of PCI bus clocks before transaction is terminated.
CLINE[1:0] R/W PCI_RST 0 CacheLine Size
00b = treated as 01
01b = 4 x 32-bit word
10b = 8 x 32-bit word
All other combinations written to this entry will return a
value of zero.
Appendix A: Registers
QSpan II User Manual206 May 16, 20 13
This register is at this location when the I20 messaging unit in the QSpan II is not used:
the I20_EN bit is set to 0 in the I2O_CS register. If the I20 messaging unit is enabled,
this register is moved to offset 018, and PCI_BST0 register from offset 018 is moved to
this offset and renamed I2O_BAR.
This register specifies the 4 Kbyte aligned base address of the QSpan II register space
on PCI in Memory Space. The QSpan II register space is 4 Kbytes, therefore the PCI
address lines [11:0] are used to select the QSpan II register.
A write must occur to this register before the QSpan II register space can be accessed
from the PCI bus. This write can be performed with a PCI configuration transaction or a
QBus register access.
Table 73: PCI Configuration Base Address for Memory Register
Register Name: PCI_BSM Register Offset: 010
Bits Function
31–24 BA
23–16 BA
15–08 BA 0 0 0 0
07–00 0 0 00000SPACE
PCI_BSM Description
Name Type Reset By Reset
State Function
BA[31:12] R/W PCI_
RST 0 Base Address
SPACE R N/A 0 PCI Bus Address Space
0 = Memory Space
Appendix A: Registers
QSpan II User Manual 207
May 16, 2013
This register is at this location when the I2O messaging unit in the QSpan II is enabled:
the I2O_EN bit is set to 1 in I2O_CS register . When the I2O_EN bit is set, the first Base
address register must provide a window to the QBus memory space. Essentially, the
PCI_BST0 register is moved from register offset 018 to 010 (see Table 75 for more
information about the programming options).
The lower 4K of this space is reserved. The region above this space provides a window
to the QBus memory.
Table 74: I20 Base Address Register
Register Name: I2O_BAR Register Offset: 010
Bits Function
31–24 BA
23–16 BA
15–08 0 0 000000
07–00 0 0 00000SPACE
I2O_BAR Description
Name Type Reset By Reset
State Function
BA[31:12] R/W NONE 0 Base Address
SPACE R N/A 0 PCI Bus Address Space
0 = Memory Space
Appendix A: Registers
QSpan II User Manual208 May 16, 20 13
This register is enabled if the state of the SDA pin or ENID pin is latched as high during
PCI reset and bit 5 of byte 7 of the EEPROM is 1 (for information, see “Mapping of
EEPROM Bits to QSpan II Registers” on page 124). This register is also enabled if the
power -up option PCI_DIS is latched high du ring Reset. If this register is not enabl ed —
for example, there is no EEPROM or bit 5 of byte 7 of the EEPROM is 0 — the entire
register is read only, and reads return all 0s.
If enabled, this register specifies the Base Address and PCI Bus Address Space settings
for PCI Bus Target Image 0. The Base Address is used during transaction decoding; it
specifies the contiguous PCI bus address line values compared by the QSpan II during
PCI bus address phases. The number of address lines compared for this image is based
on the value of the Block Size field in the PBTI0_CTL register (see Table 89 on
page 222 and “Transactio n Decod ing ” on page 59 for more information).
If this register is enabled, the number of writable bits in BA[31:16] i s determined by the
Block Size field of the PBTI0_CTL register. After power-up the serial EEPROM
contents are loaded and a PCI host can write all 1s to the BA field of this register. The
number of 1s that are read back can be used to compute the block size of the image
(Block Size = 64Kbytes * 2). For example, if the Block Size is 64 Kbytes (BS=0000)
then the BA field will be 0xFFFF. If the Block Size is 2 Gbytes (BS = 1111) then the BA
field will be 0x8000.
Table 75: PCI Configuration Base Address for Target 0 Register
Register Name: PCI_BST0 Register Offset: 018
Bits Function
31–24 BA
23–16 BA
15–08 0 0 0 0 0 0 0 0
07–00 0 0 0 0 PREF 0 0 PAS
PCI_BST0 Description
Name Type Reset By Reset
State Function
BA[31:16] See
Below PCI_RST 0 Base Address of PCI bus Target Image 0
PREF R/WQ/E PCI_RST See
Below Prefetchable
0 = Not Prefetchable
1 = Prefetchable (reads have no side effects)
PAS R PCI_RST See
Below PCI Bus Address Space
0 = Memory Space
1 = I/O Space
Appendix A: Registers
QSpan II User Manual 209
May 16, 2013
The PREF bit can be loaded from the EEPROM, or programmed from QBus. This bit
does not enable prefetching on the QBus. The PREN bit in PBTI0_CTL register must
be set to enable prefetching on QBus.
Table 76: PCI Address Lines Compared as a Function of Block Size
BS Block Size Address Lines Compared
0000 64 Kbyte s AD31–AD16
0001 128 Kbytes AD31–AD17
0010 256 Kbytes AD31–AD18
0011 512 Kbytes AD31–AD19
0100 1 Mbyte AD31–AD20
0101 2 Mbytes AD31–AD21
0110 4 Mbytes AD31–AD22
0111 8 Mbytes AD31–AD23
1000 16 Mbytes AD31–AD24
1001 32 Mbytes AD31–AD25
1010 64 Mbytes AD31–AD26
1011 128 Mbytes AD31–AD27
1100 256 Mbytes AD31–AD28
1101 512 Mbytes AD31–AD29
1110 1 Gbyte AD31–AD30
1111 2 Gbytes AD31
Appendix A: Registers
QSpan II User Manual210 May 16, 20 13
This register is enabled if the state of the SDA or ENID pin is latched as high during
PCI reset and bit 7 of byte 8 of the EEPROM is 1. This register is also enabled if the
power-up option PCI_DIS is latched high during Reset. If this register is not enabled
(for example, there is no EEPROM or bit 7 of byte 8 of the EEPROM is 0), the entire
register is read only, and reads return all zeros.
If enabled this register specifies the Base Address and PAS fields for PCI Bus Target
Image 1. The Base Address is used during transaction decoding; it specifies the
contiguous PCI bus address line values compared by the QSpan II during PCI bus
address phases. The number of address lines compared for this image is base d on the
value of the Block Size field in the PBTI1_CTL register. (see “Transaction Decoding”
on page 59).
If this register is enabled, the number of writable bits in BA[31:16] i s determined by the
Block Size field of the PBTI1_CTL register (see Table 92 on page 226). After power -up
the serial EEPROM contents are loaded and a PCI host can write all 1s to the BA field
of this register. The number of 1s that are read ba ck can be used to compute the block
size of the image (Block Size = 64Kbytes * 2). For example, if the Block Size is 64
Kbytes (BS=0000) then the BA field will be 0xFFFF. If the Block Size is 2 Gbytes (BS
= 1111), then the BA fi eld will be 0x8000.
Table 77: PCI Configuration Base Address for Target 1 Register
Register Name: PCI_BST1 Register Offset: 01C
Bits Function
31–24 BA
23–16 BA
15–08 0 0 0 0 0 0 0 0
07–00 0 0 0 0 PREF 0 0 PAS
PCI_BST1 Description
Name Type Reset By Reset
State Function
BA[31:16] See
Below PCI_RST 0 Base Address of PCI Target Image 1
PREF R/WQ/E PCI_RST See
Below Prefetchable
0 = Not Prefetchable
1 = Prefetchable (reads have no side effects)
PAS R PCI_RST See
Below PCI Bus Address Space of PCI Target Image 1
0 = Memory Space
1 = I/O Space
Appendix A: Registers
QSpan II User Manual 211
May 16, 2013
The PREF bit can be loaded from the EEPROM, or written from the QBus. The PREN
bit in PBTI1_CTL register must be set to enable QSpan II to perform prefetched reads
on the QBus.
Table 78: PCI Address Lines Compared as a Function of Block Size
BS Block Size Address Lines Compared
0000 64 Kbytes AD31–AD16
0001 128 Kbytes AD31–AD17
0010 256 Kbytes AD31–AD18
0011 512 Kbytes AD31–AD19
0100 1 Mbyte AD31–AD20
0101 2 Mbytes AD31–AD21
0110 4 Mbytes AD31–AD22
0111 8 Mbytes AD31–AD23
1000 16 Mbytes AD31–AD24
1001 32 Mbytes AD31–AD25
1010 64 Mbytes AD31–AD26
1011 128 Mbytes AD31–AD27
1100 256 Mbytes AD31–AD28
1101 512 Mbytes AD31–AD29
1110 1 Gbyte AD31–AD30
1111 2 Gbytes AD31
Appendix A: Registers
QSpan II User Manual212 May 16, 20 13
The Subsystem ID and the Subsystem Vendor ID is loaded from an external serial
EEPROM at the end of the PCI bus reset (RST#); if the state of the SDA pin or ENID
pin is latched as high during the reset. If the state of the SDA pin or ENID pin is latched
as low, the reset state of the register will be all zeros.
Writes to the PCI_SID register from the QBus will propagate to its contents, except
while the QSpan II is updating its contents from the EEPROM. Writes to the PCI_SID
register from the PCI bus do not affect its contents.
Table 79: PCI Configuration Subsystem ID Register
Register Name: PCI_SID Register Offset: 02C
Bits Function
31–24 SID
23–16 SID
15–08 SVID
07–00 SVID
PCI_SID Description
Name Type Reset By Reset
State Function
SID[15:0] R/WQ/E PCI_RST See
Below Subsystem ID
Values for Subsystem ID are vendor specific.
SVID[15:0] R/WQ/E PCI_RST Se e
Below Subsystem Vendor ID
Subsystem Vendor IDs are obtained from the PCI SIG and
are used to identify the vendor of the add-in board or
subsystem.
Appendix A: Registers
QSpan II User Manual 213
May 16, 2013
The number of writable bits in BA[31:16] determines the size of the external QBus
Expansion ROM (for more information, see the PCI Local Bus Specification 2.2).
The number of bits itself is determined by the Block Size field of the PCI Expansion
ROM Control register (see “PBRO M_CTL” on page 230). After power-up a PCI host
can write all 1s to the BA field of this register. The number of 1s that are read-back will
indicate the size of the Expansion ROM of the QSpan II.
This register is enabled if bit 7 of byte 5 of the EEPROM is latched as 1 (see Table 44
on page 125). If the state of this bit is 0 or if the state of the SDA pin or ENID pin is
latched as low during PCI reset, then all bits in the entire register will be set to 0 and
will be read only.
Table 80: PCI Configuration Expansion ROM Base Address Register
Register Name: PCI_BSROM Register Offset: 030
Bits Function
31–24 BA
23–16 BA
15–08 0 0 0 0 0 0 0 0
07–00 0 0 0 0 0 0 0 EN
PCI_BSROM Description
Name Type Reset By Reset
State Function
BA[31:16] See
Below PCI_RST See
Below Expansion ROM Base Address
EN See
Below PCI_RST 0 Enable Address Decode
0 = Disable
1 = Enable
Appendix A: Registers
QSpan II User Manual214 May 16, 20 13
The PCI Expansion ROM Base Address register can be written from either bus, if write
enabled, except while the QSpan II is loading data from an external serial EEPROM.
Writes to bits in the PCI Expansion ROM Base Address register that are not write
enabled will have no effect.
Table 81: Writable BA bits as a function of Block Size
BS Block Size Read/Write Bits
000 64 Kbytes BA31–BA16
001 128 Kbytes BA31–BA17
010 256 Kbytes BA31–BA18
011 512 Kbytes BA31–BA19
100 1 Mbyte B A31–BA20
101 2 Mbytes BA31–BA21
110 4 Mbytes BA31–BA22
111 8 Mbytes BA31–BA23
Appendix A: Registers
QSpan II User Manual 215
May 16, 2013
Table 82: PCI Capabilities Pointer Register
Register Name: PCI_CP Register Offset: 034
Bits Function
31–24 PCI Reserved
23–16 PCI Reserved
15–08 PCI Reserved
07–00 CAP_PT
PCI_CP Description
Name Type Reset By Reset
State Function
CAP_PT[7:0] R PCI_RST 0xDC Capabilities Pointer
Points to the first entry of the linked list of new capabilities
implemented by QSpan II.
Appendix A: Registers
QSpan II User Manual216 May 16, 20 13
The INT_PIN[0] can be loaded from the serial EEPROM or written from the QBus,
before configuration by an external Host. A value of 1 indicates that the QSpan II uses a
single PCI interrupt (INT#). A value of 0 indicates that the QSpan II does not use any
PCI interrupts.
When QSpan II is setup to not use any PCI i nterrupts, it is up to an external agent to set
the INT_LINE to the appropriate value.
Table 83: PCI Configuration Miscellaneous 1 Register
Register Name: PCI_MISC1 Register Offset: 03C
Bits Function
31–24 MAX_LAT
23–16 MIN_GNT
15–08 INT_PIN
07–00 INT_LINE
PCI_MISC1 Description
Name Type Reset By Reset
State Function
MAX_LAT[7:0] R/WQ/E PCI_RST 0 Maximum Latency
MIN_GNT[7:0] R/WQ/E PCI_RST 0 Minimum Grant
INT_PIN[7:1] R PCI_RST 0 Interrupt Pin (7 to 1)
INT_PIN[0] R/WQ/E PCI_RST See below Interrupt Pin 0
INT_LINE[7:0] R/W PCI_RST 0x00 Interrupt Line
Appendix A: Registers
QSpan II User Manual 217
May 16, 2013
Table 84: PCI Power Management Capabilities Register
Register Name: PCI_PMC Register Offset: 0DC
Bits Function
31–24 PME_SP D2_SP D1_SP Reserved
23–16 Reserved DSI APS PME_CLK PM_VER
15–08 NXT_IP
07–00 CAP_ID
PCI_PMC Description
Name Type Reset By Reset
State Function
PME_SP[4:0] R/WQ/E PCI_RST 0 PME_Support
Indicates the power states in which QSpan II asserts PME#.
0X001b = PME# can be asserted from D0
0100Xb = PME# can be asserted from D3hot
Bits 4, 2 and 1 are set to 0, since QSpan II never asserts
PME# when in D3cold, D2 or D1.
D2_SP R PCI_RST 0 D2 Support
Set to 0 to indicate that D2 power state is not supported.
D1_SP R PCI_RST 0 D1 Support
Set to 0 to indicate that D1 power state is not supported.
DSI R/WQ/E PCI_RST 0 Device-Specific Initialization.
APS R PCI_RST 0 Auxiliary Power Source
Set to 0, since PME# is not supported from D3cold.
PME_CLK R PCI_RST 0 PME Clock
Set to 1 to indicate that a clock is required to assert PME#
when any of the PME_SP bits are set to 1. Set to 0 when all
the PME_SP bits are 0.
PM_VER[2:0] R/WQ/E PCI_RST 001 Power Management Version
A value of 001 indicates that this device complies with
Revision 1.0 of the PCI Power Management Interface
Specification 1.1.
NXT_IP[7:0] R PCI_RST 0xE4 Next Item Pointer
Set to 0xE4 to indicate that the next item in the QSpan II
capabilities list (Compact PCI Hot Swap) is located at
offset E4h.
CAP_ID[7:0] R PCI_RST 0x01 Capability ID
Set to 0x01 to identify the linked list item as PCI Power
Management Register.
Appendix A: Registers
QSpan II User Manual218 May 16, 20 13
Table 85: PCI Power Management Contr ol and Status Register
Register Name: PCI_PMCS Register Offset: 0E0
Bits Function
31–24 Reserved
23–16 P2P_BSE
15–08 PME_ST Reserved PME_EN
07–00 Reserved PWR_ST
PCI_PMCS Description
Name Type Reset By Reset
State Function
P2P_BSE[7:0] R PCI_RST 0x00 PCI to PCI Bridge Support Extensions
PME_ST R/Write 1
to clear PCI_RST 0 PME_Status
This bit is set when QSpan II would normally assert PME#,
regardless of PME_EN bit.
PME_EN R/W PCI_RST 0 PME Enable
0 = Disable
1 = Enable
Enables the QSpan II to assert PME#.
PWR_ST[1:0] R/W PCI_RST 0 Power State
This field is used to both determine the current power state
and set the QSpan II into a new power state. If an
unimplemented power state is written to this register, the
QSpan II completes the write, but ignores the write data.
D0 and D3hot are the only states implemented.
00b: D0
11b: D3hot
Appendix A: Registers
QSpan II User Manual 219
May 16, 2013
If the QSpan II is enabled for Vital Product Data (VPD) access, the next pointer will
point to the VPD register (NXT_IP = 0xE8). Otherwise NXT_IP will be set to 0x00,
which indicates that it is the last item in the Capabilities Linked List.
Table 86: CompactPCI Hot Swap Re gist er
Register Name: CPCI_HS Register Offset: 0E4
Bits Function
31–24 Reserved
23–16 INS EXT Reserved Reserved LOO Reserved EIM Reserved
15–08 NXT_IP
07–00 CAP_ID
CPCI_HS Description
Name Type Reset By Reset
State Function
INS R/Write 1
to clear PCI_RST 0 ENUM# Status Insertion
0 = Not asserted
1 = ENUM# asserted
The QSpan II sets this bit when EEPROM load is
completed and PCI Disable bit (PCI_DIS in MISC_CTL2)
is cleared.
EXT R/Write 1
to clear PCI_RST 0 ENUM# Status Extraction
0 = Not asserted
1 = ENUM# asserted
The QSpan II sets this bit when HS_SWITCH is sampled
high and RST# is negated.
LOO R/W PCI_RST 0 LED On/Off
0 = LED off
1 = LED on
EIM R/W PCI_RST 0 ENUM# Interrupt Mask
0 = Enable Interrupt
1 = Mask Interrupt
NXT_IP[7:0] R/W PCI_RST See
Below Next Item Pointer
CAP_ID[7:0] R/W PCI_RST 0x06 Capability ID
Set to 0x06 to identify the linked list item as Compact PCI
Hot Swap Register.
Appendix A: Registers
QSpan II User Manual220 May 16, 20 13
Table 87: PCI Vital Product Data Register
Register Name: PCI_VPD Register Offset: 0E8
Bits Function
31–24 VPD_F Reserved
23–16 VPD_ADDR
15–08 NXT_IP
07–00 CAP_ID
PCI_VPD Description
Name Type Reset By Reset
State Function
VPD_F R/W PCI_RST 0 VPD Flag
Initiates a VPD serial EEPROM access and indicates
completion.
When written with a 1, QSpan II writes the 4 bytes in
VPD_DATA to the EEPROM. QSpan II sets VPD_F to 0,
when the write is complete.
When written with a 0, QSpan II reads the 4 bytes from
the EEPROM and store them in VPD_DATA. QSpan II
sets VPD_F to 1, when the read is complete.
VPD_ADDR
[7:0] R/W PCI_RST 0 x00 VPD Address
4 byte aligned byte address of the VPD to be accessed.
NXT_IP[7:0] R PCI_RST 0 x00 Next Item Pointer
This is the last item in the linked list, so the pointer is set
to 0.
CAP_ID[7:0] R PCI_RST 0x03 Capability ID
Set to 0x03 to indicate that this linked list register supports
the Vital Product Data access.
Appendix A: Registers
QSpan II User Manual 221
May 16, 2013
Table 88: PCI VPD Data Register
Register Name: VPD_DATA Register Offset: 0EC
Bits Function
31–24 VPD_DATA
23–16 VPD_DATA
15–08 VPD_DATA
07–00 VPD_DATA
PCI_VPD Description
Name Type Reset By Reset
State Function
VPD_DATA
[31:0] R/W PCI_RST 0 VPD Data
This contains the VPD read or write data. On a read, this
register will be valid, after the read was initiated and the
QSpan II sets the VPD_F bit to 1. On a write, the data
should be written to this field before the write is initiated
by writing to the PCI_VPD register.
VPD_DATA[7:0] will contain the byte specified by the
VPD_ADDR.
Appendix A: Registers
QSpan II User Manual222 May 16, 20 13
Table 89: PCI Bus Target Image 0 Control Registe r
Register Name: PBTI0_CTL Register Offset: 100
Bits Function
31–24 EN Reserved BS
23–16 PREN BRSTWREN Reserved INVEND Reserved
15–08 TC DSIZE Reserved
07–00 PWEN PAS Reserved
PBTI0_CTL Description
Name Type Reset By Reset
State Function
EN R/W G_RST 0 Image Enable
0 = Disable
1 = Enable
BS[3:0] See
Below PCI_RST See
Below Block Size (64 Kbyte*2BS)
PREN R/W G_RST 0 Prefetch Read Enable
0 = Disable
1 = Enable
BRSTWREN R/W G_RST 0 Burst Write Enable
0 = Disable
1 = Enable
INVEND R/W G_RST 0 Invert Endianness from QB_BOC Setting in MISC_CTL
0 = Use QB_BOC setting
1 = Invert QB_BOC setting
TC[3:0] R/W G_RST 0 QBus Transaction Code
User Defined
DSIZE R/W G_RST 0 QBus Destination Port Size
00b = 32-bit
01b = 8-bit
10b = 16-bit
11b = Reserved
PWENaR/W G_RST 0 Posted Write Enable
0 = Disable
1 = Enable
PAS See
Below PCI_RST See
Below PCI Bus Address Space
0 = PCI Bus Memory Space
1 = PCI Bus I/O Space
a. Only PCI bus memory space transactions can be posted.
Appendix A: Registers
QSpan II User Manual 223
May 16, 2013
The BS[3:0] and PAS fields can be loaded from an external serial EEPROM (see
“Mapping of EEPROM Bits to QSpan II Registers” on page 124). There are three cases:
1. If the fields are loaded from the EEPROM, then the EEPROM determines their
reset state, and they become read only (except as described in (3)). In this case, the
PAS bit has the same value as the bit of the same name in the PCI_BST0 register
(see Table 75 on page 208).
2. If the BS[3:0] and PAS fields are not loaded from the EEPROM, their reset state is
0, and they are writable. Note that in this case the PCI_BST0 register is disabled.
3. If the power-up option (PCI_DIS) is set high during reset, then BS[3:0] and PAS
fields are writable from the QBus, even if they were loaded from the EEPROM.
Appendix A: Registers
QSpan II User Manual224 May 16, 20 13
The Base Address specifies the contiguous PCI bus address line values compared by the
QSpan II during PCI bus address phases. The number of address lines compared for this
image is based on the Block Size (programmed in the PBTI0_CTL register on Table 89
on page 222).
The Translation Addre ss specifies the values of the address lines substituted when
generating the address for the transaction on the QBus. If no translation is to occur, the
Translation Address must be programmed with the same value as that of the Base
Address (see “T ransaction Decoding” on page 59 and “Address Translation” on page 40
for more details).
Table 90: PCI Bus Target Image 0 Address Register
Register Name: PBTI0_ADD Register Offset: 104
Bits Function
31–24 BA
23–16 BA
15–08 TA
07–00 TA
PBTI0_A DD Descripti on
Name Type Reset By Reset
State Function
BA[31:16] See
Below PCI_RST See below Base Address
TA[31:16] R/W G_RST 0 Translation Address
Appendix A: Registers
QSpan II User Manual 225
May 16, 2013
The read/write type and reset value of the BA[31:16] field depends on whether the
PCI_BST0 register (see Table 75 on page 208) is “enabled” (for example, whether bit 5
of byte 7 of the EEPROM is 1 or po wer-up pin PCI_DIS is latched high during PCI
reset). There are two cases:
1. If the EEPROM bit is 1 or PCI_DIS is latched high, the BA field of PBTI0_ADD is
read only and has the same value as the PCI_BST0 register from reset onwards.
2. If one of the following occurs then the entire BA field of PBTI0_ADD is readable
and writable: the EEPROM bit was 0, the SDA pin and ENID pins are 0 at PCI
reset, or PCI_DIS is latched low. A read from this field after reset returns all 0s. In
this case, the BA field of this register is independent of the PCI_BST0 register (the
PCI_BST0 register does not exist).
The presence of EEPROM does not affect TA[31:16].
Table 91: PCI Address Lines Compared as a Function of Block Size
BS Block Size Address Lines
Compared/Translated
0000 64 Kbytes AD31–AD16
0001 128 Kbytes AD31–AD17
0010 256 Kbytes AD31–AD18
0011 512 Kbytes AD31–AD19
0100 1 Mbyte AD31–AD20
0101 2 Mbytes AD31–AD21
0110 4 Mbytes AD31–AD22
0111 8 Mbytes AD31–AD23
1000 16 Mbytes AD31–AD24
1001 32 Mbytes AD31–AD25
1010 64 Mbytes AD31–AD26
1011 128 Mbytes AD31–AD27
1100 256 Mbytes AD31–AD28
1101 512 Mbytes AD31–AD29
1110 1 Gbyte AD31–AD30
1111 2 Gbytes AD31
Appendix A: Registers
QSpan II User Manual226 May 16, 20 13
Table 92: PCI Bus Target Image 1 Control Registe r
Register Name: PBTI1_CTL Re gister Offset: 110
Bits Function
31–24 EN Reserved BS
23–16 PREN BRSTWREN Reserved INVEND Reserved
15–08 TC DSIZE Reserved
07–00 PWEN PAS Reserved
PBTI1_CTL Description
Name Type Reset By Reset
State Function
EN R/W G_RST 0 Image Enable
0 = Disable
1 = Enable
BS[3:0] See
Below PCI_RST See
Below Block Size (64 Kbyte*2BS)
PREN R/W G_RST 0 Prefetch Read Enable
0 = Disable
1 = Enable
BRSTWREN R/W G_RST 0 Burst Write Enable
0 = Disable
1 = Enable
INVEND R/W G_RST 0 Invert Endia n-ness from QB_BOC Setting in MISC_CTL
0 = Use QB_BOC setting
1 = Invert QB_BOC setting
TC[3:0] R/W G_RST 0 QBus Transaction Code
User Defined
DSIZE[1:0] R/W G_RST 0 QBus Destination Port Size
00b = 32-bit
01b = 8-bit
10b = 16-bit
11b = Reserved
PWENaR/W G_RST 0 Posted Write Enable
0 = Disable
1 = Enable
PAS See
Below PCI_RST See
Below PCI Bus Address Space
0 = PCI Bus Memory Space
1 = PCI Bus I/O Space
a. Only PCI bus Memory Space transactions can be posted.
Appendix A: Registers
QSpan II User Manual 227
May 16, 2013
The BS[3:0] and PAS fields can be loaded from an external serial EEPROM. (see
“Mapping of EEPROM Bits to QSpan II Registers” on page 124) for more details).
There are three cases:
1. If the BS[3:0] and PAS fields are loaded from the EEPROM, then the EEPROM
determines their reset state and they become read only; except as described in 3. In
this case, the PAS bit has the same value as the bit of the same name in the
PCI_BST1 register (see Table 77 on page 210).
2. If the fields are not loaded from the EEPROM, their reset state is 0, and they are
writable. Note that in this case the PCI_BST1 register is disabled.
3. If the power-up option (PCI_DIS) is set high during reset, then BS[3:0] and PAS
fields are writable from the QBus, even if they were loaded from the EEPROM.
Appendix A: Registers
QSpan II User Manual228 May 16, 20 13
The Base Address specifies the contiguous PCI bus address line values compared by the
QSpan II during PCI bus address phases. The number of address lines compared for this
image is based on the Block Size (programmed in the PBTI1_CTL register on Table 92
on page 226).
The Translation Addre ss specifies the values of the address lines substituted when
generating the address for the transaction on the QBus. If no translation is to occur, the
Translation Address must be programmed with the same value as that of the Base
Address (see “T ransaction Decoding” on page 59 and “Address Translation” on page 40
for more details).
Table 93: PCI Bus Target Image 1 Address Register
Register Name: PBTI1_ADD Register Offset: 114
Bits Function
31–24 BA
23–16 BA
15–08 TA
07–00 TA
PBTI1_A DD Descripti on
Name Type Reset By Reset
State Function
BA[31:16] See
Below PCI_RST See
Below Base Address
See Note
TA[31:16] R/W G_RST 0 Translation Address
Appendix A: Registers
QSpan II User Manual 229
May 16, 2013
The read/write type of this register depends on whether the PCI_BST1 register (see
Table 77 on page 210) is enabled. For example, whether bit 7 of byte 9 of the EEPROM
is 1 or power-up pin PCI_DIS is latched high during PCI reset. There are two cases:
1. If the EEPROM bit is 1 or PCI_DIS pin is latched high, the BA field of
PBTI1_ADD is read only and has the same value as the PCI_BST1 register from
reset onwards.
2. If the EEPROM bit is 0 (or the SDA pin and ENID pins are 0 at PCI reset) or
PCI_DIS pin is latched low, then the entire BA field of PBTI1_ADD is readable
and writable. A read from this field after reset returns a 16-bit vector of 0s. In this
case, the BA field of this register is independent of the PCI_BST1 register (the
PCI_BST1 register does not exist).
The presence of EEPROM does not affect TA[31:16].
Table 94: PCI Address Lines Compared as a Function of Block Size
BS Block Size Address lines Compared/Translated
0000 64 Kbytes AD31–AD16
0001 128 Kbytes AD31–AD17
0010 256 Kbytes AD31–AD18
0011 512 Kbytes AD31–AD19
0100 1 Mbyte AD31–AD20
0101 2 Mbytes AD31–AD21
0110 4 Mbytes AD31–AD22
0111 8 Mbytes AD31–AD23
1000 16 Mbytes AD31–AD24
1001 32 Mbytes AD31–AD25
1010 64 Mbytes AD31–AD26
1011 128 Mbytes AD31–AD27
1100 256 Mbytes AD31–AD28
1101 512 Mbytes AD31–AD29
1110 1 Gbyte AD31–AD30
1111 2 Gbytes AD31
Appendix A: Registers
QSpan II User Manual230 May 16, 20 13
The PCI Bus Expansion ROM Control Register is loaded from an external serial
EEPROM at the conclusion of the PCI bus reset (RST#) if the state of the SDA I/O pin
or ENID is latched as high during the reset and bit 7 of byte 5 o f the EEPROM is a 1
(see “Mapping of EEPROM Bits to QSpan II Registers” on page 124). Otherwise the
reset state of the register will be zero and the register will be write disabled.
The PCI Expansion ROM Base Address register specifies the address line values that
are compared during the address decoding. The number of address lines that are
compared is based upon the value of Block Size value in the PCI Expansion ROM
Control register.
The Translation Addre ss field specifies the values of the address lines that are
substituted when generating the address for the QBus. If no translation is to occur, the
Translation Address field is programmed with the same value as that of the PCI
Configuration Expansion ROM Base Address register.
Table 95: PCI Bus Expansion ROM Control Register
Register Name: PBROM_CTL Register Offset: 13C
Bits Function
31–24 Reserved DSIZE
23–16 0 BS TC
15–08 TA
07–00 TA
PBROM_CTL Description
Name Type Reset By Reset
State Function
DSIZE[1:0] See
Below PCI_RST See below QBus Destination Port Size
00b = 32-bit
01b = 8-bit
10b = 16-bit
11b = reserved
BS[2:0] See
Below PCI_RST See below Block Size (64 Kbyte*2BS)
TC[3:0] See
Below PCI_RST See below QBus T ransaction Code
User Defined
TA[31:16] See
Below PCI_RST See below Translation Address
See below
Appendix A: Registers
QSpan II User Manual 231
May 16, 2013
Table 96: PCI Address Lines Compared as a Function of Block Size
BS Block Size A ddress Lines Compared/translated
000 64 Kbytes A31–A16
001 128 Kbytes A31–A17
010 256 Kbytes A31–A18
011 512 Kbytes A31–A19
100 1 Mbyte A31–A20
101 2 Mbytes A31–A21
110 4 Mbytes A31–A22
111 8 Mbytes A31–A23
Appendix A: Registers
QSpan II User Manual232 May 16, 20 13
The PCI Master Module sets the ES bit if one of the following occu rs:
a posted write transaction results in a Target-Abort
a posted write transaction results in a Master-Abort
The assertion of the ES bit can be mapped to the QSpan II's interrupt pins by
programming the Interrupt Control and Interrupt Direction Control registers. The
mapping of interrupts can only occur if the EN bit in the PCI Bus Error Log register is
set.
To disable the PCI Error Logging after it has been enabled, the ES bit must not be set. If
ES is set, it can be cleared (by writing a 1) at the same time as a 0 is written to the EN
bit.
Table 97: PCI Bus Error Log Control and Status Register
Register Name: PB_ERRCS Register Offset: 140
Bits Function
31–24 EN Reserved ES
23–16 UNL_QSC Reserved
15–08 Reserved
07–00 CMDERR BE_ERR
PB_ERRCS Description
Name Type Reset By Reset
State Function
EN R/W G_RST 0 Enable PCI Error Log
0 = disable error logging
1 = enable error logging
ES R/W rite 1
to Clear G_RST 0 Error Status
0 = no error currently logged,
1 = error currently logged
UNL_QSC R/W G_RST 0 Unlock QBus Slave Channel
0 = Transfers in QBus Slave Channel are suspended when
ES bit is set
1 = T ransfers in QBus Slave Channel continue while ES bit
is set
CMD_ERR
[3:0] R N/A 0111 PCI Command Error Log
BE_ERR[3:0] R G_RST 0 PCI Byte Enable Error Log
0 = byte enable active
1 = byte enable inactive
Appendix A: Registers
QSpan II User Manual 233
May 16, 2013
The BE_ERR field only contains valid in formation when the ES bit is set. At all other
times these fields return all zeros when read.
Setting the UNL_QSC enables the QBus Master to service the QBus Slave Channel
while the ES bit is set and the Error log is frozen. The ES bit must be cleared to log a
new error. If error logging is enabled, it recommended that the UNL_QSC bit be set to
1.
Appendix A: Registers
QSpan II User Manual234 May 16, 20 13
The QSpan II as PCI master will log errors if a posted write transaction results in a
Target-Abort, or a posted write transaction results in a Master-Abort.
This register logs the PCI bus address information. Its content are qualified by bit ES of
the PCI Bus Error Log Control and Status Register (see Table 97). The PAERR field
contains valid information when the ES bit is set. At all other times a read of this
register will return all zeros.
Table 98: PCI Bus Address Error Log Register
Register Name: PB_AERR Register Offset: 144
Bits Function
31–24 PAERR
23–16 PAERR
15–08 PAERR
07–00 PAERR
PB_AERR Description
Name Type Reset By Reset
State Function
PAERR[31:0] R G_RST 0 PCI Address Error Log
Appendix A: Registers
QSpan II User Manual 235
May 16, 2013
The QSpan II as PCI master will log errors if a posted write transaction results in a
Target-Abort, or a posted write transaction results in a Master-Abort.
This register logs the PCI bus data information. Its content are qualified by bit ES of the
PCI Bus Error Log Control and Status register (see Table 97). The PDERR field
contains valid information when the ES bit is set. At all other times, a read of this
register will return all zeros.
Table 99: PCI Bus Data Err or Log Register
Register Name: PB_DERR Register Offset: 148
Bits Function
31–24 PDERR
23–16 PDERR
15–08 PDERR
07–00 PDERR
PB_DERR Description
Name Type Reset By Reset
State Function
PDERR[31:0] R G_RST 0 PCI Data Error Log
Appendix A: Registers
QSpan II User Manual236 May 16, 20 13
Table 100: I2O Control and Status Register
Register Name: I2O_CS Register Offset: 200
Bits Function
31–24 QIBA
23–16 QIBA Reserved
15–08 IF_E IP_E OF_E OP_E IF_F IP_F OF_F OP_F
07–00 Reserved FIFO_SIZE Reserved Reserved RR_BP I2O_EN
I2O_CS Description
Name Type Reset By Reset
State Function
QIBA[31:20] R/W G_RST 0 QBus I2O Base Address
Base address of the block of memory that contains the four
FIFOs in QBus memory. The four FIFOs (two Inbound and
two Outbound) are of equal size, but need not be in contiguous
memory locations. QIBA is aligned to a 1-Mbyte address
boundary.
IF_E R G_RST 1 Inbound Free_List FIFO Empty
0 = Not Empty
1 = Empty
IP_E R G_RST 1 Inbound Post_List FIFO Empty
0 = Not Empty
1 = Empty
OF_E R G_RST 1 Outbound Free_List FIFO Empty
0 = Not Empty
1 = Empty
OP_E R G_RST 1 Outbound Post_List FIFO Empty
0 = Not Empty
1 = Empty
IF_F R G_RST 0 Inbound Free_List FIFO Full
0 = Not Full
1 = Full
IP_F R G_RST 0 Inbound Post_List FIFO Full
0 = Not Full
1 = Full
OF_F R G_RST 0 Outbound Free_List FIFO Full
0 = Not Full
1 = Full
Appendix A: Registers
QSpan II User Manual 237
May 16, 2013
OP_F R G_RST 0 Outbound Post_List FIFO Full
0 = Not Full
1 = Full
FIFO_SIZE [2:0] R/W G_RST 0 This field specifies the size of the circular FIFO. All four
FIFOs are the same size and queue 32-bit entries. Total FIFO
memory allocation is four times the single FIFO size.
000b = 256 entries (1 Kbyte FIFO size)
001b = 1K entries (4 Kbyte FIFO size)
010b = 4K entries (16 Kbyte FIFO size)
011b = 16K entries (64 Kbyte FIFO size)
100b = 64K entries (256 Kbyte FIFO size)
others = Reserved
RR_BP R/W G_RST 0 Register Read of Bottom Pointer
0 = Register read of bottom pointer will return value of bottom
pointer
1 = same as 0, except when the top and bottom pointers are
equal, returns 0xFFFFFFFF
I2O_EN R/W G_RST 0 I2O Enable
0 = accesses to I2O Inbound and Outbound Queue are enabled
1 = accesses to I2O Inbound and Outbound Queue are
disabled. W rites are accepted but ignored, reads return 0xFFFF
FFFF. All pointer initialization and frame allocation should be
completed before enabling this bit.
I2O_CS Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual238 May 16, 20 13
Table 101: I2O Inbound Free_List Top Pointer Register
Register Name: IIF_TP Register Offset: 204
Bits Function
31–24 QIBA
23–16 QIBA IF_TP
15–08 IF_TP
07–00 IF_TP Reserved
IIF_TP Description
Name Type Reset By Reset
State Function
QIBA [31:20] R G_RST 0 QBus I2O Base Address (specified in I2O_CS)
IF_TP [19:2] R/W G_RST 0 Inbound Free_List Top Pointer
This pointer gives the address offset for the Inbound
Free-List Top Pointer. This register is initialized and
maintained by the QBus Host.
Appendix A: Registers
QSpan II User Manual 239
May 16, 2013
Table 102: I2O Inbound Free_List Bottom Pointer Register
Register Name: IIF_BP Register Offset: 208
Bits Function
31–24 QIBA
23–16 QIBA IF_BP
15–08 IF_BP
07–00 IF_BP Reserved
IIF_BP Description
Name Type Reset By Reset
State Function
QIBA [31:20] R G_RST 0 QBus I2O Base Address (specified in I2O_CS)
IF_BP [19:2] R/W G_RST 0 Inbound Free_List Bottom Pointer
This pointer gives the address offset for the Inbound
Free-List Bottom Pointer. This register is initialized by the
QBus Host, but is maintained by QSpan II and is
incremented by four (modulo boundary of FIFO_SIZE).
Appendix A: Registers
QSpan II User Manual240 May 16, 20 13
Table 103: I2O Inbound Post_List Top Pointer Register
Register Name: IIP_TP Register Offset: 20C
Bits Function
31–24 QIBA
23–16 QIBA IP_TP
15–08 IP_TP
07–00 IP_TP Reserved
IIP_TP Description
Name Type Reset By Reset
State Function
QIBA [31:20] R G_RST 0 QBus I2O Base Address (specified in I2O_CS)
IP_TP [19:2] R/W G_RST 0 Inbound Post_List Top Pointer
This pointer gives the address offset for the Inbound
Post-List Top Pointer. This register is initialized by the
QBus Host, but is maintained by QSpan II and is
incremented by four (modulo boundary of FIFO_SIZE).
Appendix A: Registers
QSpan II User Manual 241
May 16, 2013
Table 104: I2O Inbound Post_List Bottom Pointer Register
Register Name: IIP_BP Register Offset: 210
Bits Function
31–24 QIBA
23–16 QIBA IP_BP
15–08 IP_BP
07–00 IP_BP Reserved
IIP_BP Description
Name Type Reset By Reset
State Function
QIBA [31:20] R G_RST 0 QBus I2O Base Address (specified in I2O_CS)
IP_BP [19:2] R/W G_RST 0 Inbound Post_List Bottom Pointer
This pointer gives the address offset for the Inbound
Post-List Bottom Pointer. This register is initialized and
maintained by the QBus Host.
Appendix A: Registers
QSpan II User Manual242 May 16, 20 13
Table 105: I2O Outbound Free_List Top Pointer Register
Register Name: IOF_TP Register Offset: 214
Bits Function
31–24 QIBA
23–16 QIBA OF_TP
15–08 OF_TP
07–00 OF_TP Reserved
IOF_TP Description
Name Type Reset By Reset
State Function
QIBA [31:20] R G_RST 0 QBus I2O Base Address (specified in I2O_CS)
OF_TP [19:2] R/W G_RST 0 Outbound Free_List Top Pointer
This pointer gives the address offset for the Outbound
Free-List Top Pointer. This register is initialized by the
QBus Host, but is maintained by the QSpan II and is
incremented by four (modulo boundary of FIFO_SIZE).
Appendix A: Registers
QSpan II User Manual 243
May 16, 2013
Table 106: I2O Outbound Free_List Bottom Pointer Register
Register Name: IOF_BP Register Offset: 218
Bits Function
31–24 QIBA
23–16 QIBA OF_BP
15–08 OF_BP
07–00 OF_BP Reserved
IOF_BP Description
Name Type Reset By Reset
State Function
QIBA [31:20] R G_RST 0 QBus I2O Base Address (specified in I2O_CS)
OF_BP [19:2] R/W G_RST 0 Outbound Free_List Bottom Pointer
This pointer gives the address offset for the Outbound
Free-List Bottom Pointer. This register is initialized and
maintained by the QBus Host.
Appendix A: Registers
QSpan II User Manual244 May 16, 20 13
Table 107: I2O Outbound Post_List Top Pointer Register
Register Name: IOP_TP Register Offset: 21C
Bits Function
31–24 QIBA
23–16 QIBA OP_TP
15–08 OP_TP
07–00 OP_TP Reserved
IOP_TP Description
Name Type Reset By Reset
State Function
QIBA [31:20] R G_RST 0 QBus I2O Base Address (specified in I2O_CS)
OP_TP [19:2] R/W G_RST 0 Outbound Post_List Top Pointer
This pointer gives the address offset for the Outbound
Post-List Bottom Pointer. This register is initialized and
maintained by the QBus Host.
Appendix A: Registers
QSpan II User Manual 245
May 16, 2013
Table 108: I2O Outbound Post_List Bottom Pointer Register
Register Name: IOP_BP Register Offset: 220
Bits Function
31–24 QIBA
23–16 QIBA OP_BP
15–08 OP_BP
07–00 OP_BP Reserved
IOP_BP Description
Name Type Reset By Reset
State Function
QIBA [31:20] R G_RST 0 QBus I2O Base Address (specified in I2O_CS)
OP_BP [19:2] R/W G_RST 0 Outbound Post_List Bottom Pointer
This pointer gives the address offset for the Outbound
Post-List Bottom Poi n te r. This register is init i al iz ed by t he
QBus Host, but is maintained by QSpan II and is incremented
by four (modulo boundary of FIFO_SIZE).
Appendix A: Registers
QSpan II User Manual246 May 16, 20 13
Table 109: IDMA Control and Status Register
Register Name: IDMA/DMA_CS Register Offset: 400
Bits Function
31–24 GO IRST_REQ Reserved
23–16 ACT IRST DONE IPE IQE CMD Reserved
15–08 IWM [3:0] TC[3:0]
07–00 TC_EN CHAIN DMA DIR IMODE QTERM STERM PORT16
IDMA/DMA_CS Description
Name Type Reset By Reset
State Function
GO W/Read 0
Always G_RST 0 IDMA/DMA Go
0 = No effect
1 = Enable IDMA/DMA transfers
IRST_REQ W/Read 0
Always G_RST 0 IDMA/DMA Reset Request
0 = No effect
1 = Request reset of IDMA/DMA control
ACT R G_RST 0 IDMA/DMA Active Status
0 = No IDMA/DMA transfer is active,
1 = IDMA/DMA transfer in progress
IRST R/Write 1
to Clear G_RST 0 IDMA/DMA Reset Status
0 = Not reset
1 = Reset
DONE R/Write 1
to Clear G_RST 0 IDMA/DMA Done Status
0 = Not done
1 = Done
IPE R/Write 1
to Clear G_RST 0 IDMA/DMA PCI Bus Error Status
0 = No error occurred
1 = Error occurred on the PCI bus during IDMA/DMA
transfer
IQE R/Write 1
to Clear G_RST 0 IDMA/DMA QBus Error Status
0 = No error occurred
1 = Error occurred on the QBus during IDMA/DMA
transfer
CMD R/W G_RST 0 PCI Command Option for IDMA/DMA PCI Transaction
0 = PCI Memory Write or Memory Read
1 = PCI Memory Write Invalidate or Memory Read Line
Appendix A: Registers
QSpan II User Manual 247
May 16, 2013
IWM [3:0] R/W G_RST 0 Programmable I-FIFO Watermark (for IDMA transfers)
0000 = use the value programmed into the CLINE[1:0]
field of the PCI_MISC0 register
x = when 16x bytes have been queued in the I-FIFO, the
IDMA channel will request the PCI bus. Watermark can be
set to a maximum of 240 bytes.
TC [3:0] R/W G_RST 0 Programmable TC Encoding with MPC860 IDMA
Program to the value expected on the QSpan II’s TC[3:0]
lines during an IDMA transfer. The intent of this field is to
allow users to use the TC lines to encode an IDMA
transaction for the QSpan II (add a qualifier for SDACK
assertion).
TC_EN R/W G_RST 0 TC Encoding Enable (IDMA transfers only)
0 = QSpan II does not decode TC[3:0] for IDMA accesses
1 = QSpan II decodes TC[3:0] for IDMA accesses
CHAIN R/W G_RST 0 DMA chaining
0 = Direct Mode DMA
1 = Linked List Mode DMA
DMA R/W G_RST 0 DMA
0 = QSpan II does an IDMA transfer
1 = QSpan II does a DMA transfer
DIR R/W G_RST 0 Direction
0 = Transfer from PCI Bus to QBus
1 = Transfer from QBus to PCI bus
IMODE R/W G_RST 0 IDMA Mode
0 = IDMA transfer is MC68360
1 = IDMA transfer is MPC860
QTERM R/W G_RST 0 Termination Mode
0 = QSpan II uses normal termination during MC68360
dual address IDMA transfers
1 = QSpan II uses fast termination during MC68360 dual
address IDMA transfers
STERM R/W G_RST 0 Slave Termination Mode
0 = External slave uses normal termination mode during
MC68360 single address IDMA transfers
1 = External slave uses fast termination during MC68360
single address IDMA transfers
PORT16 R/W G_RST 0 QBus Port 16
0 = Source/destination on QBus is a 32-bit port
1 = Source/destination on QBus is a 16-bit port
IDMA/DMA_CS Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual248 May 16, 20 13
The QTERM bit is important when the QSpan II is operating as an MC68360 IDMA
peripheral device during dual address IDMA transfers. During all other conditions this
bit does not affect the QSpan II’s operation.
The STERM bit is important when the QSpan II is operating as an MC68360 IDMA
peripheral device during single address IDMA transfers. During all other conditions this
bit does not affect the QSpan II’s operation.
The IDMA/DMA Channel can be reset from either bus while it is in progress by writing
1 to the IRST_REQ bit (see “IDMA Errors, Resets, and Interrupts” on page 89). If the
ACT bit is 0, then setting IRST_REQ to 1 has no effect.
The DONE bit is set by the QSpan II if its transfer count expires in the IDMA/DMA
Transfer Count register, or the DONE_ signal is asserted by the MC68360 during
IDMA transfers. Under either condition the QSpan II's IDMA controller will return to
the idle state, which is indicated by the ACT bit.
The IRST, DONE, IPE and IQE events can be mapped to the interrupt pins on either bus
using the QSpan II’s Interrupt Control Registers (see Table 120 on page 263). See
Chapter 5: “The IDMA Channel” on page 83 for more information.
The programmable I-FIFO Watermark (IWM[3:0]) must be programmed
with a value less than or equal to the value programmed in the IDMA
Transfer Count Register.
Appendix A: Registers
QSpan II User Manual 249
May 16, 2013
The ADDR field must be programmed with the absolute PCI address for an
IDMA/DMA transaction. This address is aligned to a 4-byte boundary. An IDMA/DMA
transfer wraps-around at the A24 boundary. If an IDMA/DMA transfer is required to
cross an A24 boundary, it must be programmed as two separate transactions. This field
is incremented by the QSpan II during a transfer. Progress of the IDMA/DMA trans f er
on the PCI bus can be monitored by reading the IDMA/DMA_CNT register (see
Table 111 on page 250).
This register can be programmed from either bus, or by the DMA controller when it
loads a command packet from QBus or PCI memory.
Table 110: IDMA/DMA PCI Ad dress Regist e r
Register Name: IDMA/DMA_PADD Register Offset: 404
Bits Function
31–24 ADDR
23–16 ADDR
15–08 ADDR
07–00 ADDR 0 0
IDMA/DMA_PADD Description
Name Type Reset By Reset
State Function
ADDR[31:2] R/W G_RST 0 PCI Bus Address for IDMA/DMA transfers
Appendix A: Registers
QSpan II User Manual250 May 16, 20 13
CNT[23:2] indicates the number of bytes left to transfer in an IDMA/DMA transaction
(see Table 111 on page 250). The QSpan II decreases this transfer counter by four with
every 32-bit transfer on the PCI bus. (The IDMA/DMA Channel on the PCI Interface
transfers 32-bit data.) The amount of data th at can be transferred within an IDMA/DMA
transaction is 16 Mbytes (for example, 222 32-bit transfers).
The CNT[23:2] field must be programmed with a minimum value of 0x000010
(corresponding to 16 bytes) otherwise the IDMA/DMA channel will not start when the
GO bit is set. The CNT field must initially be programmed with the same value as the
processors IDMAs Byte Count register when IDMA transfers are initiated.
This register can be programmed from either bus, or is programmed by the DMA
controller when it loads a command packet from QBus or PCI memory. The command
packet only contains CNT[19:2], making the maximum Linked List transfer size 1
Mbyte.
Table 111: IDMA/DMA Transfer Count Register
Register Name: IDMA/DMA_CNT Register Offset: 408
Bits Function
31–24 Reserved
23–16 CNT
15–08 CNT
07–00 CNT 0 0
IDMA/DMA_CNT Descriptiona
Name Type Reset By Reset
State Function
CNT[23:2] R/W G_RST 0 IDMA/DMA Transfer Count
Number of Bytes to Transfer (Max = 222 * 4 bytes)
a. The IDMA/DMA_CNT should not be programmed to be less than the specified value in the watermark field,
IWM.
Appendix A: Registers
QSpan II User Manual 251
May 16, 2013
The Q_ADDR[31:2] field must be programmed with the absolute QBus address for the
DMA transaction. This address is aligned to a 4-byte boundary. A DMA transfer
wraps-around at an A24 boundary. If a DMA transfer is required to cross an A24
boundary, it must be programmed as two separate transactions. This field is not
incremented by the QSpan II during a transfer: progress of the DMA transfer on the PCI
bus can be monitored by reading the IDMA/DMA_CNT register (see Table 111 on
page 250).
This register can be programmed from either bus, or is programmed by the DMA
controller when it loads a command packet from QBus or PCI memory.
Table 112: DMA QBus Address Register
Register Name: DMA_QADD Register Offset: 40C
Bits Function
31–24 Q_ADDR
23–16 Q_ADDR
15–08 Q_ADDR
07–00 Q_ADDR 0 0
DMA_QADD Description
Name Type Reset By Reset
State Function
Q_ADDR[31:2] R/W G_RST 0 QBus Address for DMA transfers
Appendix A: Registers
QSpan II User Manual252 May 16, 20 13
Table 113: DMA Control and Status Register
Register Name: DMA_CS Register Offset: 410
Bits Function
31–24 TC DIR DSIZE INVEND
23–16 IWM Reserved Q_OFF
15–08 BURST_4 BRSTEN Reserved MDBS CP_LOC
07–00 STOP STOP_
STAT Reserved
DMA_CS Description
Name Type Reset By Reset
State Function
TC[3:0] R/W G_RST 0 QBus Transaction Code (for DMA transfers)
User Defined
DIR R G_RST 0 DMA Direction
0 = Transfer from PCI Bus to QBus
1 = T ransfer from QBus to PCI bus (read-only copy of DIR
bit in IDMA/DMA_CS)
DSIZE[1:0] R/W G_RST 0 QBus Destination Port Size
00 = 32-bit
01 = 8-bit
10 = 16-bit
11 = reserved
INVEND R/W G_RST 0 Invert Endia n-ness from QB_BOC Setting in MISC_CTL
0 = Use QB_BOC setting
1 = Invert QB_BOC setting
IWM[3:0] R/W G_RST 0 Programmable I-FIFO Watermark
0000 = use the value programmed into the CLINE[1:0]
field of the PCI_MISC0 register
x = when 16x bytes have been queued in the I-FIFO, the
DMA channel will request the PCI bus. Watermark can be
set to a maximum of 128 bytes (1000)
others = Reserved
Appendix A: Registers
QSpan II User Manual 253
May 16, 2013
The generation of burst cy cles is supported when the QSpan II is powered up in
MPC860 Master mode. The DMA QBus OFF counter is activated when a DMA
transfer crosses a 256-byte address boundary on the QBus. For example, the counter is
active after each 256-byte transfer on the QBus when MDBS = 0, otherwise 64-byte
boundary is used.
A DMA transfer in progress can be stopped by setting the STOP bit. The DMA transfer
is stopped once any active transfer is completed. The STOP_STAT is set when the
DMA is stopped. To restart the DMA, a 0 must be written to the STOP bit.
Q_OFF R/W G_RST 0 DMA QBus Off Counter
000b = 0
001b = 64
010b = 128
011b = 256
100b = 512
101b = 1024
others = Reserved
The DMA controller will not request the QBus until the
programmed number of QCLKs expires.
BURST_4 R/W G_RST 0 QBus Burst Four Dataphases
0 = QSpan II will generate partial QBus burst (2 or 3
dataphases)
1 = QSpan II will only generate QBus burst with 4
dataphases
BRSTEN R/W G_RST 0 QBus Burst Enable
0 = Disable
1 = Enable
MDBS R/W G_RST 0 Maximum DMA Burst Size on QBus
0 = 256 Bytes
1 = 64 Bytes
CP_LOC R/W G_RST 0 Command Packet Locatio n
0 = PCI Bus
1 = QBus
STOP R/W G_RST 0 DMA Stop
0 = Resume DMA transfer
1 = Stop DMA transfer
STOP_STAT R G_RST 0 DMA Stop Status
0 = DMA transfer is not stopped
1 = DMA transfer is stopped
DMA_CS Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual254 May 16, 20 13
This register can be programmed from either bus. The upper 12 bits [31:20 ] can al so b e
loaded from a command packet when in Linked List mode.
The CP_LOC indicates the location of the command packet in either QBus or PCI Bus
memory. All the command packets in a linked list must be in either PCI or QBus
memory, and not both.
Appendix A: Registers
QSpan II User Manual 255
May 16, 2013
This register contains the pointer to the next command packet. Initially it is
programmed to the starting packet of the Linked List, and is updated with the address to
the next command packet when a command packet is loaded from memory. The packets
must be aligned to a 16-byte address.
Table 11 4: DMA Command Packet Pointer Register
Register Name: DMA_CPP Register Offset: 414
Bits Function
31–24 CPP
23–16 CPP
15–08 CPP
07–00 CPP Reserved
DMA_CPP Description
Name Type Reset By Reset
State Function
CPP[31:4] R/W G_RST 0 DMA Command Packet Pointer
Appendix A: Registers
QSpan II User Manual256 May 16, 20 13
An access to the PCI Configuration Data Register (see Table 1 17 on page 258) from the
QBus Interface performs a corresponding Configuration cycle on the PCI bus. The type
of configuration cycle generated by the QSpan II is a function of the TYPE bit.
If the TYPE bit set to 1, an access of the PCI Configuration Data register from the QBus
interface performs a corresponding Configuration Type 1 cycle on the PCI bus. During
the address phase of the Configuration Type 1 cycle on the PCI bus, the PCI address
lines carry the values encoded in the Configuration Address Register
(AD[31:0] = CON_ADDR[31:0]).
Table 115: Configuration Address Register
Register Name: CON_ADD Register Offset: 500
Bits Function
31–24 0 0 0 0 0 0 0 0
23–16 BUS_NUM
15–08 0 DEV_NUM FUNC_NUM
07–00 REG_NUM 0 TYPE
CON_ADD Description
Name Type Reset By Reset
State Function
BUS_NUM
[7:0] R/W G_RST 0 Bus Number
DEV_NUM
[3:0] R/W G_RST 0 Device Number
FUNC_NUM
[2:0] R/W G_RST 0 Function Number
REG_NUM
[5:0] R/W G_RST 0 Register Number
TYPE R/W G_RST 0 Configuration Cycle Type
0 = Type 0
1 = Type 1
The QSpan II cannot perform a Type 0 Configuration cycle to a PCI
tar get that has its IDSEL input connected to one of the AD[15..1 1] signals
— bit 15 of the CON_ADD register is hardcoded as 0. Therefore, for host
bridging applications the hardware designer must choose to drive each
PCI target's IDSEL input from one of the AD[31..16] signals.
Appendix A: Registers
QSpan II User Manual 257
May 16, 2013
If the TYPE bit set to 0, an access of the PCI Configuration Data register from the QBus
interface performs a corresponding Configuration Type 0 cycle on the PCI bu s.
Programming the Device Number causes one of the upper address lines, AD[31:16], to
be asserted during the address phase of the Configuration Type 0 cycle. (Table 115
shows which PCI address line is asserted as a function of the DEV_NUM[3:0] field.)
The remaining address lines during the address phase of the Configuration cycle are
controlled by the Function Number and Register Number:
AD[15:11] = 00000
AD[10:8] = FUNC_NUM[2 :0]
AD[7:2] = REG_NUM[5:0]
AD[1:0] = 00
Table 116: PCI AD[31:16] lines asserted as a function of DEV_NUM field
DEV_NUM[3:0] AD[31:16]
0000 0000 0000 0000 0001
0001 0000 0000 0000 0010
0010 0000 0000 0000 0100
0011 0000 0000 0000 1000
0100 0000 0000 0001 0000
0101 0000 0000 0010 0000
0110 0000 0000 0100 0000
0111 0000 0000 1000 0000
1000 0000 0001 0000 0000
1001 0000 0010 0000 0000
1010 0000 0100 0000 0000
1011 0000 1000 0000 0000
1100 0001 0000 0000 0000
1101 0010 0000 0000 0000
1110 0100 0000 0000 0000
1111 1000 0000 0000 0000
Appendix A: Registers
QSpan II User Manual258 May 16, 20 13
A write to the PCI Configuration Data register from the PCI bus has no effect. A read
from the PCI bus always returns all zeros. A write to the Configuration Data register
from the QBus causes a Configuration Write Cycle to be generated on the PCI as
defined by the Configuration Address register (see Table 115). A read of this register
from the QBus causes a Configuration Read Cycle to be generated on the PCI bus. The
PCI bus Configuration cycles generated by accessing the Configuration Data register
are processed as delayed transfers.
The QSpan II does not perform byte swapping of data in the Register Channel
regardless of whether the QBus is configured as big or little endian. Bit 31 in the
register is bit 31 on the QBus regardless of the QB_BOC bit in the MISC_CTL register
(see Table 127 on page 274). Therefore, software on the QBus may need to swap the
data when performing configuration cycles.
Table 117: Configuration Data Register
Register Name: CON_DATA Register Offset: 504
Bits Function
31–24 CDATA
23–16 CDATA
15–08 CDATA
07–00 CDATA
CON_DATA Description
Name Type Reset By Reset
State Function
CDATA[31:0] R/W G_RST 0 Configuration Data
The QSpan II generates a bus error upon a register access to the
CON_DATA register if the bus master (BM) bit in the PCI_CS register is
not set.
Appendix A: Registers
QSpan II User Manual 259
May 16, 2013
This register generates an Interrupt Acknowledge cycle originating on the QBus.
Reading this register from the QBus causes an IACK cycle to be generated on the PCI
bus. The byte lanes enabled on the PCI bus are determined by SIZ[1:0] and A[1:0] of
the QBus read. The address on the QBus used to access the IACK_GEN register is
passed to the PCI bus during the PCI IACK cycle. Address information, however, is
ignored during PCI IACK cycles, so this has no effect.
Reads from this register act as delayed transfers. This means that the QBus master is
retried until the read data is latched from the PCI target. When the IACK cycle
completes on the PCI bus, the IACK_VEC[31:0] field is returned as read data when the
QBus master returns after the retry.
W riti ng to this register from the QBus or PC I bus has no effect. Reads from the PCI bus
return all zeros.
The QSpan II does not perform byte swapping of data in the Register Channel
regardless of whether the QBus is configured as big or little endian. Bit 31 in the
register is bit 31 on the QBus regardless of the QB_BOC bit in the MISC_CTL register
(see Table 127 on page 274). Therefore, software on the QBus may need to swap the
data when performing IACK cycles.
Table 118: IACK Cycle Generator Register
Register Name: IACK_GEN Register Offset: 508
Bits Function
31–24 IACK_VEC
23–16 IACK_VEC
15–08 IACK_VEC
07–00 IACK_VEC
IACK_GEN Description
Name Type Reset By Reset
State Function
IACK_VEC
[31:0] RGEN_RST 0 PCI IACK Cycle Vector
QSpan II generates a bus error upon register access to the IACK_GEN
register if the bus master (BM) bit in the PCI_CS register is not set.
Appendix A: Registers
QSpan II User Manual260 May 16, 20 13
Table 119: Interrupt Status Register
Register Name: INT_STAT Register Offset: 600
Bits Function
31–24 PEL_IS QEL_IS MDPED_IS PCSR_IS IQE_IS IPE_IS IRST_IS DONE_IS
23–16 INT_IS PERR_IS SERR_IS QINT_IS MB3_IS MB2_IS MB1_IS MB0_IS
15–08 QDPE_S PSC_IS OPNE_S IPN_IS IFE_S OFE_S IPF_S OFF_S
07–00 Reserved SI3_IS SI2_IS SI1_IS SI0_IS
INT_STAT Description
Name Type Reset By Reset
State Function
PEL_IS R/W rite 1
to Clear G_RST 0 PCI Bus Error Log Interrupt Status
QEL_IS R/Write 1
to Clear G_RST 0 QBus Error Log Interrupt Status
MDPED_IS R/Write 1
to Clear G_RST 0 PCI Master Data Parity Detected Interrupt Status
PCSR_IS R/Write 1
to Clear G_RST 0 PCI_CS Register Interrupt Status
IQE_IS R/Write 1
to Clear G_RST 0 IDMA/DMA QBus Error Interrupt Status
IPE_IS R/Write 1
to Clear G_RST 0 IDMA/DMA PCI Error Interrupt Status
IRST_IS R/W rite 1
to Clear G_RST 0 IDMA/DMA Reset Interrupt Status
DONE_IS R/Write 1
to Clear G_RST 0 IDMA/DMA Done Interrupt Status
INT_IS R/Write 1
to Clear G_RST 0 Status of PCI interrupt input to QBus interrupt output
PERR_IS R/Write 1
to Clear G_RST 0 Status of PCI bus PERR# input to QBus interrupt output
SERR_IS R/Write 1
to Clear G_RST 0 Status of PCI bus SERR# input to QBus interrupt output
QINT_IS R/Write 1
to Clear G_RST 0 Status of QBus interrupt input to PCI interrupt output
MB3_IS R/Write 1
to Clear G_RST 0 MailBox3 Interrupt Status
Appendix A: Registers
QSpan II User Manual 261
May 16, 2013
Interrupt status bits are set upon the assertion of the interrupt condition. Each interrupt
status bit in the Interrupt Stat us register will remain set unti l a 1 is written to it. Clearing
of the interrupt status bit will not clear the source status bit that may have caused the
interrupt to be asserted. As part of the interrupt handling routine, a separate register
transaction to the corresponding status register must occur.
MB2_IS R/Write 1
to Clear G_RST 0 MailBox2 Interrupt Status
MB1_IS R/Write 1
to Clear G_RST 0 MailBox1 Interrupt Status
MB0_IS R/Write 1
to Clear G_RST 0 MailBox0 Interrupt Status
QDPE_S R/Write 1
to Clear G_RST 0 QBus Data Parity Error Status
PSC_IS R/Write 1
to Clear G_RST 0 Power State Changed Interrupt Status
OPNE_S R G_RST 0 Outbound Post_List Not Empty Status
This bit is set when the Outbound Post_List is not empty.
IPN_IS R/Write 1
to Clear G_RST 0 Inbound Post_List New Entry Interrupt Status
This bit is set when a new entry is posted into the Inbound
Post_List.
IFE_S R G_RST 1 Inbound Free_List Empty Status
This bit is set when the Inbound Free_List is empty.
OFE_S R G_RST 1 Outbound Free_List Empty Status
This bit is set when the Outbound Free_List is empty.
IPF_S R G_RST 0 Inbound Post_List Full Status
This bit is set when the Inbound Post_List is full.
OFF_S R G_RST 0 Outbound Free_List Full Status
This bit is set when the Outbound Free_List is full.
SI3_IS R/Write 1
to Clear G_RST 0 Software Interrupt 3 Status
SI2_IS R/Write 1
to Clear G_RST 0 Software Interrupt 2 Status
SI1_IS R/Write 1
to Clear G_RST 0 Software Interrupt 1 Status
SI0_IS R/Write 1
to Clear G_RST 0 Software Interrupt 0 Status
INT_STAT Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual262 May 16, 20 13
For instance, the MDPED_IS bit is set — if it is enabled — when the MD_PED bit in
the PCI Configuration Control and Status Register is set. To clear this interrupt, clear
both status bits.
I2O related status bits (OPNE_S, IFE_S, OFE_S, IPF_S, OFF_S) are set regardless of
the corresponding interrupt enable bit in INT_CTL register. Only IPN_IS status bit is
set when the interrupt enable bit (IP N_EN in INT_CTL) is set and a new entry (MFA) is
posted into the Inbound Post_List FIFO.
Appendix A: Registers
QSpan II User Manual 263
May 16, 2013
Table 120: Interrupt Control Register
Register Name: INT_CTL Register Offset: 604
Bits Function
31–24 PEL_EN QEL_EN MDPED_EN PCSR_EN IQE_EN IPE_EN IRST_EN DONE_EN
23–16 INT_EN PERR_EN SERR_EN QINT_EN MB3_EN MB2_EN MB1_EN MB0_EN
15–08 QDPE_EN PSC_EN OPNE_EN IPN_EN IFE_EN OFE_EN IPF_EN OFF_EN
07–00 Reserved SI1 SI0
INT_CTL Description
Name Type Reset By Reset
State Function
PEL_EN R/W G_RST 0 PCI Bus Error Log Interrupt Enable
0 = Disable mapping of PCI error log interrupt
1 = Enable mapping of interrupt
QEL_EN R/W G_RST 0 QBus Error Log Interrupt Enable
0 = Disable mapping of QBus error log interrupt
1 = Enable mapping of interrupt
MDPED_EN R/W G_RST 0 PCI Master Data Parity Detected Interrupt Enable
0 = Disable mapping of Master Data Parity Detected
interrupt
1 = Enable mapping of interrupt
PCSR_EN R/W G_RST 0 PCI_CS Register status bit set Interrupt Enable
0 = Disable mapping of PCI_CS Register status bit set
interrupt
1 = Enable mapping of interrupt
IQE_EN R/W G_RST 0 IDMA/DMA QBus Error Interrupt Enable
0 = Disable mapping of IDMA QBus error interrupt
1 = Enable mapping of interrupt
IPE_EN R/W G_RST 0 IDMA/DMA PCI Error Interrupt Enable
0 = Disable mapping of IDMA PCI error interrupt
1 = Enable mapping of interrupt
IRST_EN R/W G_RST 0 IDMA/DMA Reset Interrupt Enable
0 = Disable mapping of IDMA reset interrupt
1 = Enable mapping of IDMA reset interrupt
DONE_EN R/W G_RST 0 IDMA/DMA Done Interrupt Enable
0 = Disable mapping of IDMA done interrupt
1 = Enable mapping of interrupt
Appendix A: Registers
QSpan II User Manual264 May 16, 20 13
INT_EN R/W G_RST 0 Map PCI bus Interrupt Input to QBus Interrupt Output
Enable
0 = Disable mapping
1 = Enable mapping of interrupt
PERR_EN R/W G_RST 0 Map Parity Error on PCI bus to QBus Interrupt Output
Enable
0 = Disable mapping
1 = Enable mapping of interrupt
SERR_EN R/W G_RST 0 Map SERR# Input to QBus Interrupt Output Enable
0 = Disable mapping
1 = Enable mapping of interrupt
QINT_EN R/W G_RST 0 Map QBus Interrupt Input to PCI Bus Interrupt Output
Enable
0 = Disable mapping
1 = Enable mapping of interrupt
MB3_EN R/W G_RST 0 MailBox3 Interrupt Enable
0 = Disable mapping
1 = Enable mapping of interrupt
MB2_EN R/W G_RST 0 MailBox2 Interrupt Enable
0 = Disable mapping
1 = Enable mapping of interrupt
MB1_EN R/W G_RST 0 MailBox1 Interrupt Enable
0 = Disable mapping
1 = Enable mapping of interrupt
MB0_EN R/W G_RST 0 MailBox0 Interrupt Enable
0 = Disable mapping
1 = Enable mapping of interrupt
QDPE_EN R/W G_RST 0 QBus Data Parity Error Interrupt Enable
0 = Disable mapping
1 = Enable mapping of interrupt
PSC_EN R/W G_RST 0 Power State Changed Interrupt Enable
0 = Disable mapping
1 = Enable mapping of interrupt
OPNE_EN R G_RST 0 Outbound Post_List Not Empty Interrupt Enable
(read-only copy based on OP_IM in I2O_OPIM register)
0 = Disable interrupt
1 = Enable interrupt when Outbound Post List is not empty
INT_CTL Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual 265
May 16, 2013
IPN_EN R/W G_RST 0 Inbound Post_List New Entry Interrupt Ena ble
0 = Disable interrupt
1 = Enable interrupt when a new entry is posted into
Inbound Post_List
IFE_EN R/W G_RST 0 Inbound Free_List Empty Interrupt Enable
0 = Disable interrupt
1 = Enable interrupt when Inbound Free_List Empty Status
is set
OFE_EN R/W G_RST 0 Outbound Free_List Empty Interrupt Enable
0 = Disable interrupt
1 = Enable interrupt when Outbound Free_List Empty
Status is set
IPF_EN R/W G_RST 0 Inbound Post_List Full Interrupt Enable
0 = Disable interrupt
1 = Enable interrupt when Inbound Post_List Full Status is
set
OFF_EN R/W G_RST 0 Outbound Free_List Full Interrupt Enable
0 = Disable interrupt
1 = Enable interrupt when Outbound Free_List Full Status
is set
SI1 W/Read 0
Always G_RST 0 Software Interrupt 1
0 = No effect
1 = Sets SI1_IS status bit
SI0 W/Read 0
Always G_RST 0 Software Interrupt 0
0 = No effect
1 = Sets SI0_IS status bit
INT_CTL Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual266 May 16, 20 13
Table 121: Interrupt Direction Register
Register Name: INT_DIR Register Offset: 608
Bits Function
31–24 PEL_DIR QEL_DIR MDPED_DIR PCSR_DIR IQE_DIR IPE_DIR IRST_DIR DONE_DIR
23–16 INT_DIR PERR_DIR SERR_DIR QINT_DIR MB3_DIR MB2_DIR MB1_DIR MB0_DIR
15–08 QDPE_DIR PSC_DIR OPNE_DIR IPN_DIR IFE_DIR OFE_DIR IPF_DIR OFF_DIR
07–00 Reserved SI3_DIR SI2_DIR SI1_DIR SI0_DIR
INT_DIR Description
Name Type Reset By Reset
State Function
PEL_DIR R/W G_RST 0 PCI Error Log Interrupt Direction
0 = Map PCI error log interrupt to the QBus
1 = Map interrupt to the PCI bus
QEL_DIR R/W G_RST 0 QBus Error Log Interrupt Direction
0 = Map QBus error log interrupt to the QBus
1 = Map interrupt to the PCI bus
MDPED_DIR R/W G_RST 0 PCI Master Data Parity Detected Interrupt Direction
0 = Map Master Data Parity Detected interrupt to the QBus
1 = Map interrupt to the PCI bus
PCSR_DIR R/W G_RST 0 PCI_CS Register status bit set Interrupt Direction
0 = Map PCI_CS Register status bit set interrupt to the QBus
1 = Map interrupt to the PCI bus
IQE_DIR R/W G_RST 0 IDMA\DMA QBus Error Interrupt Direction
0 = Map IDMA\DMA QBus error interrupt to the QBus
1 = Map interrupt to the PCI bus
IPE_DIR R/W G_RST 0 IDMA\DMA PCI Error Interrupt Direction
0 = Map IDMA\DMA PCI error interrupt to the QBus
1 = Map interrupt to the PCI bus
IRST_DIR R/W G_RST 0 IDMA\DMA Reset Interrupt Direction
0 = Map IDMA\DMA reset interrupt to the QBus
1 = Map interrupt to the PCI bus
DONE_DIR R/W G_RST 0 IDMA\DMA Done Interrupt Direction
0 = Map IDMA done interrupt to the QBus
1 = Map IDMA done interrupt to the PCI bus
INT_DIR R G_RST 0 PCI Interrupt mapping Direction
Always mapped to QBus.
PERR_DIR R G_RST 0 PCI Parity Error mapping Direction
Always mapped to the QBus.
Appendix A: Registers
QSpan II User Manual 267
May 16, 2013
SERR_DIR R G_RST 0 PCI SERR# mapping Direction
Always mapped to QBus.
QINT_DIR R G_RST 1 QBus Interrupt mapping Direction
Always mapped to PCI Bus.
MB3_DIR R/W G_RST 0 MailBox3 Interrupt Direction
0 = Map MailBox3 interrupt to the QBus
1 = Map MailBox3 interrupt to the PCI bus
MB2_DIR R/W G_RST 0 MailBox2 Interrupt Direction
0 = Map MailBox2 interrupt to the QBus,
1 = Map MailBox2 interrupt to the PCI bus
MB1_DIR R/W G_RST 0 MailBox1 Interrupt Direction
0 = Map MailBox1 interrupt to the QBus
1 = Map MailBox1 interrupt to the PCI bus
MB0_DIR R/W G_RST 0 MailBox0 Interrupt Direction
0 = Map MailBox0 interrupt to the QBus,
1 = Map MailBox0 interrupt to the PCI bus
QDPE_DIR R/W G_RST 0 QBus Data Parity Error Interrupt Direction
0 = Map QBus Data Parity Error interrupt to the QBus,
1 = Map interrupt to the PCI bus
PSC_DIR R G_RST 0 Power State Changed Interrupt Direction
Always mapped to QBus.
OPNE_DIR R G_RST 1 Outbound Post_List Not Empty Interrupt Direction
Always mapped to PCI Bus.
IPN_DIR R G_RST 0 Inbound Post_List New Entry Interrupt Direction
Always mapped to QBus.
IFE_DIR R/W G_RST 0 Inbound Free_List Empty Interrupt Direction
0 = Map Inbound Free_List Empty interrupt to QBus
1 = Map interrupt to the PCI bus
OFE_DIR R/W G_RST 0 Outbound Free_List Empty Interrupt Direction
0 = Map Outbound Free_List Empty interrupt to QBus
1 = Map interrupt to the PCI bus
IPF_DIR R/W G_RST 0 Inbound Post_List Full Interrupt Direction
0 = Map Inbound Post_List Full interrupt to QBus
1 = Map interrupt to the PCI bus
OFF_DIR R/W G_RST 0 Outbound Free_List Full Interrupt Direction
0 = Map Outbound Free_List Full interrupt to QBus
1 = Map interrupt to the PCI bus
INT_DIR Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual268 May 16, 20 13
SI3_DIR R/W G_RST 0 Software Interrupt 3 Direction
0 = Map software interrupt to the QBus
1 = Map interrupt to the PCI bus
SI2_DIR R/W G_RST 0 Software Interrupt 2 Direction
0 = Map software interrupt to the QBus
1 = Map interrupt to the PCI bus
SI1_DIR R/W G_RST 0 Software Interrupt 1 Direction
0 = Map software interrupt to the QBus
1 = Map interrupt to the PCI bus
SI0_DIR R/W G_RST 0 Software Interrupt 0 Direction
0 = Map software interrupt to the QBus
1 = Map interrupt to the PCI bus
In order for an interrupt to be mapped to either bus, it must also have its
corresponding interrupt enable set in the Interrupt Control Register (see
Table 120 on page 263).
INT_DIR Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual 269
May 16, 2013
Table 122: Interrupt Control Register 2
Register Name: INT_CTL2 Register Offset: 60C
Bits Function
31–24 Reserved
23–16 Reserved
15–08 Reserved
07–00 Reserved SI3 SI2 Reserved
INT_CTL2 Description
Name Type Reset By Reset
State Function
SI3 W/Read 0
Always G_RST 0 Software Interrupt 3
0 = No effect
1 = Sets SI3_IS status bit
SI2 W/Read 0
Always G_RST 0 Software Interrupt 2
0 = No effect
1 = Sets SI2_IS status bit
Appendix A: Registers
QSpan II User Manual270 May 16, 20 13
Ta ble 123: Mailbox 0 Register
Register Name: MBOX0 Register Offset: 700
Bits Function
31–24 MB_DATA
23–16 MB_DATA
15–08 MB_DATA
07–00 MB_DATA
MBOX0 Description
Name Type Reset By Reset
State Function
MB_DATA
[31:0] R/W GEN_RST 0 MailBox Data
Appendix A: Registers
QSpan II User Manual 271
May 16, 2013
Ta ble 124: Mailbox 1 Register
Register Name: MBOX1 Register Offset: 704
Bits Function
31–24 MB_DATA
23–16 MB_DATA
15–08 MB_DATA
07–00 MB_DATA
MBOX1 Description
Name Type Reset By Reset
State Function
MB_DATA
[31:0] R/W GEN_RST 0 MailBox Data
Appendix A: Registers
QSpan II User Manual272 May 16, 20 13
Ta ble 125: Mailbox 2 Register
Register Name: MBOX2 Register Offset: 708
Bits Function
31–24 MB_DATA
23–16 MB_DATA
15–08 MB_DATA
07–00 MB_DATA
MBOX2 Description
Name Type Reset By Reset
State Function
MB_DATA
[31:0] R/W GEN_RST 0 MailBox Data
Appendix A: Registers
QSpan II User Manual 273
May 16, 2013
Ta ble 126: Mailbox 3 Register
Register Name: MBOX3 Register Offset: 70C
Bits Function
31–24 MB_DATA
23–16 MB_DATA
15–08 MB_DATA
07–00 MB_DATA
MBOX3 Description
Name Type Reset By Reset
State Function
MB_DATA
[31:0] R/W GEN_RST 0 MailBox Data
Appendix A: Registers
QSpan II User Manual274 May 16, 20 13
Table 127: Miscellaneous Control and Status Register
Register Name: MISC_CTL Register Offset: 800
Bits Function
31–24 SW_RST Reserved
23–16 Reserved S_BG S_BB 0 QB_BOC
15–08 Reserved MA_BE_D Reserved QFIFO_B
LK8 QFIFO_M
ODE
07–00 PRCNT[5:0] MSTSLV
MISC_CTL Description
Name Type Reset By Reset
State Function
SW_RST R/W G_RST 0 QBus Software Reset Control
0 = software reset not active
1 = software reset active
S_BG R/W G_RST See below Synchronous Bus Grant
0 = BG_ input is asynchronous to QCLK
1 = BG_ input is synchronous to QCLK
S_BB R/W G_RST See below Synchronous Bus Grant Acknowledge
0 = BG_ input is asynchronous to QCLK
1 = BG_ input is synchronous to QCLK
QB_BOC R/W G_RST 0 QBus Byte Ordering Control
0 = QBus uses Big-Endian byte ordering
1 = QBus uses PCI Little-Endian byte ordering
MA_BE_DaR/W G_RST 0 Master-Abort - Bus Error Mapping Disable
Applies to delayed transfers.
0 = When QSpan II issues a PCI Master-Abort, it maps this
termination to the QBus as a bus error (behaves in the same
manner as previous QSpan designs)
1 = When QSpan II receives a PCI Master-Abort it maps
this as a normal termination on the QBus. On writes, data is
flushed from the channel, and on reads the QSpan II returns
all ones. In order to comply with the PCI 2.2 Specification,
the MA_BE_D bit should be set to 1 before any PCI
configuration cycles are performed, if the QSpan II is being
used as a host bridge.
QFIFO_BLK8 R/W G_RST 0 This bit must be set to 0.
QFIFO_MODE R/W G_RST 0 This bit must be set to 0.
Appendix A: Registers
QSpan II User Manual 275
May 16, 2013
The SW_RST bit allows the QBus reset output (RESETO_) to be controlled in software
from the PCI bus. When 1 is written to this bit, the QSpan II asserts RESETO_. There
are three ways to cause the QSpan II to terminate the software reset state:
1. Clear the SW_RST bit by writing 0 to it. In this case, RESET O_ is immediately
negated.
2. Assert RESETI_. In this case, the SW_RST bit is immediately cleared (set to 0)
and RESETO_ is immediately negated.
3. Assert RST#. In this case, SW_RST is immediately cleared (set to 0), however
RESETO_ continues to be asserted until RST# is negated.
The reset state of S_BG and S_BB depends on the master mode of the QSpan II (see
Table 127). If the Master Mode is MC68360, then the reset state of S_BG and S_BB is
0. If the Master Mode i s MPC860 or M680 40, then the reset state of S_BG and S_BB is
1.
The QB_BOC bit affects the transfer of data onto the QBus Interface in cases where the
data passes through the QBus Slave Channel, the PCI Target Channel, or the
IDMA/DMA Channel. There are two situations to be aware of:
1. The PBTIx_CTL and DMA_CS registers contain an INVEND bit which causes the
QSpan II to use the logical inversion of the QB_BOC.
2. The QB_BOC bit does not affect the presentation of data on the QBus Interface in
the case where the Register Channel is accessed.
PRCNT[5:0] R/W G_RST 000001 Prefetch Read Byte Co unt
This field controls how much data the QSpan II prefetches
on the QBus. The number of bytes prefetched is four times
the number programmed into this register (for example,
001100b is 48 bytes)
MSTSLV[1:0] R G_RST See
Table 128 Master/Slave Mode
a. If you want to map a PCI Target-Abort as an Error on the QBus — and the MA_BE_D bit is set — the TA_BE_EN
bit in MISC_CTL2 register must also be set.
Unexpected results can occur if the output RESETO_ on the QBus
Interface of the QSpan II is used to generate the input RESETI_.
MISC_CTL Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual276 May 16, 20 13
With the second situation, the QSpan II does not perform byte swapping of data in the
Register Channel regardless of whether the QBus is configured as Big or Little endian;
this applies to all QBus register accesses, including the CON_DATA and IACK
registers. Bit 31 in any QSpan II register is presented on bit 31 of the QBus (and bit 31
of the PCI bus) regardless of the QB_BOC bit.
The MSTSLV field indicates the Master and Slave modes of the QSpan II. The first bit
of this field is determined by the value of BDIP_ at reset. The second bit is determined
by the value of SIZ[1] at reset. The MSTSLV field is described in Table 127.
Table 128: Master/Slave Mode — MSTSLV field
MSTSLV field M aster Mode Slave Mode
00 MC68360 MC68360 and M68040
01 MC68360 MC68360 and MPC860
10 M68040 MC68360 and M68040
11 MPC860 MC68360 and MPC860
Appendix A: Registers
QSpan II User Manual 277
May 16, 2013
This register is provided for users to read to, or write from the EEPROM through the
QBus or the PCI bus. This register accepts reads or writes when the ACT bit is 0,
therefore the ACT bit might need to be polled before a write is attempted. The ACT bit
is 1 when the QSpan II is loading data from the EEPROM, or is in the process of
completing a read or write to the EEPROM caused by an access to this register.
W rites complete on the QBus or the PCI bus regardless of the state of the ACT bit (and,
therefore, regardless of whether the write to the DATA field was effective).
It there is no EEPROM (the SDA pin and ENID pin are low at PCI reset), then this
register is read-only and reads return all zeros (see “Programming the EEPROM from
the QBus or PCI Bus” on page 127 for more information). Access to EEPROM can be
enabled after power-up using the EEPROM_ACC bit in the MISC_CTL2 register (see
“EEPROM Access” on page 128).
Table 129: EEPROM Control and Status Register
Register Name: EEPROM_CS Register Offset: 804
Bits Function
31–24 ADDR[7:0]
23–16 DATA[7:0]
15–08 Reserved
07–00 ACT READ Reserved
EEPROM_CS Description
Name Type Reset By Reset
State Function
ADDR[7:0] See Below PCI_RST See Belo w EEPROM read and write address
DATA[7:0] See Below PCI_RST See Below EEPROM read and write data
ACT R PCI_RST 0EEPROM Active
0 = No
1 = Yes
READ R/W PCI_RST 0 EEPROM Read bit
0 = Write to EEPROM
1 = Read to EEPROM
Appendix A: Registers
QSpan II User Manual278 May 16, 20 13
Table 130: Miscellaneous Control 2 Regi ster
Register Name: MISC_CTL2 Register Offset: 808
Bits Function
31–24 PCI_DIS Reserved
23–16 PTP_IB KEEP_BB MAX_RTRY PTC_PD TA_BE_
EN BURST_4 PR_
SING
15–08 PRCNT2 REG_AC QSC_PW
07–00 Reserved QBUS_
PAR EEPROM
_ACC NOTO PSC_
QRST QINT_
PME
MISC_CTL2 Description
Name Type Reset By Reset
State Function
PCI_DIS R/W G_RST See below PCI Access Disabled
0 = Access from PCI interface is enabled
1 = All access to QSpan II from PCI interface is retried
PTP_IB R/W G_RST 0 PCI Target Channel Prefetch Count Image Based
0 = Prefetch count is not image based (use PRCNT in
MISC_CTL)
1 = Prefetch count is image based
(PRCNT = Image 0, PRCNT2 = Image 1)
KEEP_BB R/W G_RST 0 Keep Bus Busy (BB_) asserted for back-to-back cycles
This bit applies to all QSpan II PCI target cycles.
0 = Bus Busy is negated after each cycle; allows change
of Bus mastership
1 = Bus Busy is kept asserted for multiple cycles
Note: Do not set this bit when the QSpan II DMA
channel is used with the PowerQUICC memory
controller (UPM).
MAX_RTRY
[1:0] R/W G_RST 0 Maximum Number of Retries completed by QSpan II as
a master on the PCI Bus
00b = Forever
01b = 128
10b = 256
11b = 384
PTC_PD R/W G_RST 0 PCI Target Channel Prefetch Disconnect
0 = TRDY# is negated between databeats until the next
data is available
1 = Cycle is terminated with Disconnect if the TRDY# is
going to be negated for more than eight PCI clocks.
Appendix A: Registers
QSpan II User Manual 279
May 16, 2013
TA_BE_EN R/W G_RST 0 PCI Target-Abort - Bus Error Mapping Enable
0 = When QSpan II receives a PCI Target-Abort it maps
this as a normal termination on the QBus (if MA_BE_D
bit in MISC_CTL is set to 1). If MA_BE_D is set to 0,
then both PCI Master-Abort and Target-Abort
terminations are translated to a Bus Error on QBus for
delayed cycles.
1 = When the QSpan II receives a PCI Target-Abort it
maps it to a Bus Error termination on the QBus for
delayed cycles.
BURST_4 R/W G_RST 0 QBus Burst 4 Data phases (for PCI target channel write
transfers)
0 = QSpan II will generate partial burst on QBus (2 or 3
data phases)
1 = QSpan II will only generate QBus burst with 4 data
phases (required for use with MPC860’s memory
controller)
PR_SING R/W G_RST 0 QBus Prefetch Single Dataphase
0 = QSpan II will prefetch using burst cycles as an
MPC860 master
1 = QSpan II will generate single cycles to prefetch data
as an MPC860 master
PR_CNT2[5:0] R/W G_RST 000001 Prefetch Read Byte Count 2
This field controls how much data the Qspan II
prefetches on the QBus for an access through the PCI
target image 1 (when above PTP_IB bit is set). The
number of bytes prefetched is 4 times the number
programmed into this field (for example, 001100 is 48
bytes)
QSC_PW R/W G_RST 0 QBus Slave Channel Posted Write
0 = Default mode (for QSpan (CA91C860B,
CA91L860B) backward compatibility)
1 = Improves the dequeuing of posted writes in the QBus
Slave Channel
REG_AC R/W G_RST 0 Register Access Control
0 = Normal Mode, register access defaults to PCI bus
1 = Register Access port is parked at the last bus to
access the register block
QBUS_PAR R/W G_RST 0 QBus Parity Encoding
0 = Even Parity
1 = Odd Parity
MISC_CTL2 Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual280 May 16, 20 13
If an EEPROM is only used for storing Vital Product Data (VPD), access to EEPROM
can be enabled after power-up — SDA and ENID low during Reset — by setting the
EEPROM_ACC bit.
To maximize the performance impro vements of the QSpan II, set the following bits to
1: BURST_4, PWEN bit in PBTIx_CTL, REG_AC, QSC_PW, and NOTO. This will
maximize performance if there are no ordering requirements between transactions in the
PCI Target Channel and the QBus Slave Channel.
QSpan II can be setup to retry all PCI access while the QBus processor is used to
configure the PCI configuratio n registers. This can be accomplished using the PCI_DIS
bit in MISC_CTL2. The power-up pin, PCI_DIS, must be pulled high during PCI reset
to set the PCI_DIS bit to 1. The PCI_DIS bit can be set to 0 by the QBus processor
when it completes programming the QSpan II register s. Once completed, this w ill then
allow the QSpan II to respond to PCI configuration cycles.
The PCI_DIS bit can also be programmed from the EEPROM, in this case after the
QSpan II registers are loaded from EEPROM, the registers can be modified by the
QBus processor before the external Host configures the QSpan II.
EEPROM_
ACC R/W G_RST 0 EEPROM Access after Power-up
0 = EEPROM access is disabled, if powered up without
EEPROM (SDA and ENID low at power-up)
1 = EEPROM access is enabled, if powered up without
EEPROM
NOTO R/W G_RST 0 No Transaction Ordering
0 = Enable T ransaction Ordering between the PCI Target
Channel and QBus Slave Channel
1 = Disable T ransaction Ordering between the PCI T arget
Channel and QBus Slave Channel
PSC_QRST R/W G_RST 0 Power State Change (D3hot to D0) causes QBus reset
0 = Power State Change from D3hot to D0, does not
cause a QBus reset
1 = Power State Change from D3hot to D0 (initiated by
the Host), causes an internal QSpan II reset and
RESETO_ to be asserted
QINT_PME R/W G_RST 0 QINT_ assertion in D3hot Power State generates PME#
0 = QINT_ assertion does not generate PME#
1 = QINT_ assertion in D3hot Power State can generate
PME# (if enabled by PME_SP in PCI_PMC register)
MISC_CTL2 Description (Continued)
Name Type Reset By Reset
State Function
Appendix A: Registers
QSpan II User Manual 281
May 16, 2013
Table 131: PCI Bus Arbiter Control Register
Register Name: PARB_CTL Register Offset: 810
Bits Function
31–24 Reserved
23–16 Reserved
15–08 M7_PRI M6_PRI M5_PRI M4_PRI M3_PRI M2_PRI M1_PRI QS_PRI
07–00 PCI_
ARB_EN Reserved PARK BM_PARK
PARB_CTL Description
Name Type Reset By Reset
State Function
Mx_PRI R/W G_RST 0 Arbitration Level for PCI Master Device x
0 = Low priority
1 = High priority
QS_PRI R/W G_RST 0 Arbitration Level for Qspa n II
0 = Low priority
1 = High priority
PCI_ARB_EN R G_RST See
Below QSpan II’s PCI Bus Arbiter
0 = Disabled
1 = Enabled
PARK R/W G_RST 0 PCI Bus Parking Scheme
0 = Last Master
1 = Select Master based on BM_PARK
BM_PARK[2:0] R/W G_RST 0 Select Master for PCI Bus Parking
Appendix A: Registers
QSpan II User Manual282 May 16, 20 13
QSpan II’s internal PCI Bus arbiter is e nabled by a power-up option. If the
PCI_ARB_EN pin is sampled high at the negation of Reset, the QSpan II arbiter is
enabled. When disabled, an external arbiter is used and REQ#/GNT# are used by the
QSpan II to arbitrate for access to the PCI Bus. If the internal arbiter is used, the
REQ#/GNT# lines can be used by an external Bus master to arbitrate for the PCI Bus.
Table 132: Parked PCI Master
BM_PARK [2:0] Parked PCI Master External Pins
000 Qspan II None
001 M1 EXT_REQ#[1]/EXT_GNT#[1]
010 M2 EXT_REQ#[2]/EXT_GNT#[2]
011 M3 EXT_REQ#[3]/EXT_GNT#[3]
100 M4 EXT_REQ#[4]/EXT_GNT#[4]
101 M5 EXT_REQ#[5]/EXT_GNT#[5]
110 M6 EXT_REQ#[6]/EXT_GNT#[6]
111 M7 REQ#/EXT_GNT#
Appendix A: Registers
QSpan II User Manual 283
May 16, 2013
The QBSI0 slave image is used when QSpan II is selected by the assertion of CSPCI_
and IMSEL (Image Select) is 0. It indicates, among other things, that the QSpan II does
not burst to PCI I/O space and responds to such attempts by generating a bus error on
the QBus (see “Transaction Decoding and QBus Slave Images” on page 37.
Tables 134 to 137 indicate how the QSpan II Slave module responds to QBus masters as
a function of the PWEN and PAS bits settings.
Values in this register (except PREN) can be programmed from a serial EEPROM (for
more information, see Chapter 9: “The EEPROM Channel” on page 121). If they are
not, their reset state is 0.
Table 133: QBus Slave Image 0 Control Register
Register Name: QBSI0_CTL Register Offset: F00
Bits Function
31–24 PWEN Reserved PAS
23–16 PREN Reserved
15–08 Reserved
07–00 Reserved
QBSI0_CTL Description
Name Type Reset By Reset
State Function
PWEN R/W/E PCI_RST See
Below Posted Write Enable
0 = Disable
1 = Enable
PAS R/W/E PCI_RST See
Below PCI Bus Address Space
0 = PCI Bus Memory Space
1 = PCI Bus I/O Space
PREN R/W PCI_RST See
Below Prefetch Read Enable
0 = Disable
1 = Enable
Appendix A: Registers
QSpan II User Manual284 May 16, 20 13
Table 134: QSpan II Response to a Single-Read Cycle Access
PREN PAS Read Cycle (R/W_ negated)
0 0 Delayed Read
0 1 Delayed Read
1 0 Delayed Prefetched Read
1 1 Delayed Read
Table 135: QSpan II Response to a Burst-Read Cycle Access
PREN PAS Read Cycle (R/W_ negated)
0 0 Delayed Read
01 Bus Error
1 0 Delayed Read
11 Bus Error
Table 136: QSpan II Response to a Single-Write Cycle Access
PWEN PAS Write Cycle (R/W_ asserted)
0 0 Delayed Write
0 1 Delayed Write
1 0 Posted Write
1 1 Delayed Write
Table 137: QSpan II Response to a Burst-Write Cycle Access
PWEN PAS Write Cycle (R/W_ asserted)
0 0 Posted Write
01 Bus Error
1 0 Posted Write
11 Bus Error
Appendix A: Registers
QSpan II User Manual 285
May 16, 2013
Table 138: QBus Slave Image 0 Address Translation Register
Register Name: QBSI0_AT Register Offset: F04
Bits Function
31–24 TA
23–16 TA
15–08 Reserved
07–00 BS Reserved EN
QBSI0_AT Description
Name Type Reset By Reset
State Function
TA[31:16] R/W/E PCI_RST See
Below Translation Address
BS[3:0] R/W/E PCI_RST See
Below Block Size (64 Kbyte*2BS)
EN R/W/E PCI_RST See
Below Enable Address Translation
0 = Disable
1 = Enable
Appendix A: Registers
QSpan II User Manual286 May 16, 20 13
The Translation Addre ss specifies the values of the address lines substituted when
generating the address for the transaction on the PCI bus. Address translation is enabled
by setting the EN bit. Block Size is used to determine which address lines are translated
(see Table 139 and “Mapping of EEPROM Bits to QSpan II Registers” on page 124).
Otherwise, their reset state is 0.
Table 139: Address Lines Translated as a Function of Block Size
BS Block Size Address Lines Translated
0000 64 Kbytes A31–A16
0001 128 Kbytes A31–A17
0010 256 Kbytes A31–A18
0011 512 Kbytes A31–A19
0100 1 Mbyte A31–A20
0101 2 Mbytes A31–A21
0110 4 Mbytes A31–A22
0111 8 Mbytes A31–A23
1000 16 Mbytes A31–A24
1001 32 Mbytes A31–A25
1010 64 Mbytes A31–A26
1011 128 Mbytes A31–A27
1100 256 Mbytes A31–A28
1101 512 Mbytes A31–A29
1110 1 Gbyte A31–A30
1111 2 Gbytes A31
Appendix A: Registers
QSpan II User Manual 287
May 16, 2013
This slave image definition is used when QSpan II is selected by the assertion of
CSPCI_ and IMSEL (Image Select) is 1. It indicates, among other things, that the
QSpan II does not burst to PCI I/O space and responds to such attempts by generating a
bus error on the QBus. Single posted writes to I/O space are treated as delayed writes
(see “Transaction Decoding and QBus Slave Images” on page 37).
Tables 141 to 144 indicate how the QSpan II Slave module responds to QBus masters as
a function of the PWEN and PAS bits setting.
Unlike Slave Image 0, this register cannot be programmed with a serial EEPROM.
Table 140: QBus Slave Image 1 Control Register
Register Name: QBSI1_CTL Register Offset: F10
Bits Function
31–24 PWEN Reserved PAS
23–16 PREN Reserved
15–08 Reserved
07–00 Reserved
QBSI1_CTL Description
Name Type Reset By Reset
State Function
PWEN R/W G_RST 0 Posted Write Enable
0 = Disable
1 = Enable
PAS R/W G_RST 0 PCI Bus Address Space
0 = PCI Bus Memory Space
1 = PCI Bus I/O Space
PREN R/W G_RST 0 Prefetch Read Enable
0 = Disable
1 = Enable
Appendix A: Registers
QSpan II User Manual288 May 16, 20 13
Table 141: QSpan II Response to a Single-Read Cycle Access
PREN PAS Read Cycle (R/W_ negated)
0 0 Delayed Read
0 1 Delayed Read
1 0 Delayed Prefetched Read
1 1 Delayed Read
Table 142: QSpan II Response to a Burst-Read Cycle Access
PREN PAS Read Cycle (R/W_ negated)
0 0 Delayed Read
01 Bus Error
1 0 Delayed Read
11 Bus Error
Table 143: QSpan II Response to a Single-Write Cycle Access
PWEN PAS Write Cycle (R/W_ asserted)
0 0 Delayed Write
0 1 Delayed Write
1 0 Posted Write
1 1 Delayed Write
Table 144: QSpan II Response to a Burst-Write Cycle Access
PWEN PAS Write Cycle (R/W_ asserted)
0 0 Posted Write
01 Bus Error
1 0 Posted Write
11 Bus Error
Appendix A: Registers
QSpan II User Manual 289
May 16, 2013
The Translation Addre ss specifies the values of the address lines substituted when
generating the address for the transaction on the PCI bus. Address translation is enabled
by setting the EN bit. The Block Size determ ines which address lines are translated (see
Table 146).
Unlike Slave Image 0, this register cannot be programmed with a serial EEPROM.
Table 145: QBus Slave Image 1 Address Translation Register
Register Name: QBSI1_AT Register Offset: F14
Bits Function
31–24 TA
23–16 TA
15–08 Reserved
07–00 BS Reserved EN
QBSI1_AT Description
Name Type Reset By Reset
State Function
TA[31:16] R/W G_RST 0 Translation Address
See below
BS[3:0] R/W G_RST 0 Block Size (64 Kbyte*2BS)
EN R/W G_RST 0 Enable Address Translation
0 = Disable
1 = Enable
Appendix A: Registers
QSpan II User Manual290 May 16, 20 13
Table 146: QBus Address Lines Compared as a function of Block Size
BS Block Size Address Lines Translated
0000 64 Kbytes A31–A16
0001 128 Kbytes A31–A17
0010 256 Kbytes A31–A18
0011 512 Kbytes A31–A19
0100 1 Mbyte A31–A20
0101 2 Mbytes A31–A21
0110 4 Mbytes A31–A22
0111 8 Mbytes A31–A23
1000 16 Mbytes A31–A24
1001 32 Mbytes A31–A25
1010 64 Mbytes A31–A26
1011 128 Mbytes A31–A27
1100 256 Mbytes A31–A28
1101 512 Mbytes A31–A29
1110 1 Gbyte A31–A30
1111 2 Gbytes A31
Appendix A: Registers
QSpan II User Manual 291
May 16, 2013
The QBus Master Module logs errors when a posted write transaction from the Px-FIFO
results in a bus error. The assertion of the ES bit can be mapped to the QSpan II's
interrupt pins by programming the Interrupt Control Register and the Interrupt
Direction Register (see Table 1 20 on page 263 and Table 121 on page 266,
respectively). The mapping of interrupts occurs if the EN bit in the QBus Error Log
Control and Status Register is set.
To disable the QBus Error Logging after it is enabled, the ES bit must not be set. If the
ES bit is set, it can be cleared by writing a 1 at the same time as a 0 is written to the EN
bit.
The TC_ERR and SIZ_ERR fields contain valid information when the ES bit is set. At
all other times these fields will return all zeros when read.
Table 147: QBus Error Log Control and Status Register
Register Name: QB_ERRCS Register Offset: F80
Bits Function
31–24 EN Reserved ES
23–16 Reserved
15–08 Reserved
07–00 TC_ERR Reserved SIZ_ERR
QB_ERRCS Description
Name Type Reset By Reset
State Function
EN R/W G_RST 0 Enable QBus Error Log
0 = Disable error logging
1 = Enable error logging
ES R/W rite 1
to Clear G_RST 0 QBus Error Status
0 = No error currently logged
1 = Error currently logged
TC_ERR[3:0] R G_RST 0 QBus Transaction Code Error Log
SIZ_ERR[1:0] R G_RST 0 QBus SIZ Field Error Log
Appendix A: Registers
QSpan II User Manual292 May 16, 20 13
The QBus Master Module will log errors when a posted write transaction results in a
bus error.
This register logs the QBus address information. Its contents are qualified by bit ES of
the QBus Error Log Control and Status Register (see Table 147 on page 291). The
QAERR field contains valid information when ES is set. At all other times, a read of
this register will return all zeros.
Table 148: QBus Address Error Log
Register Name: QB_AERR Register Offset: F8 4
Bits Function
31–24 QAERR
23–16 QAERR
15–08 QAERR
07–00 QAERR
QB_AERR Description
Name Type Reset By Reset
State Function
QAERR[31:0] R G_RST 0 QBus Address Error Log
Appendix A: Registers
QSpan II User Manual 293
May 16, 2013
The QBus Master Module will log errors when a posted write transaction results in a
bus error.
This register logs the QBus data information. Its contents are qualified by bit ES of the
QBus Error Log Control and Status register (see Table 147 on page 291).
Table 149: QBus Data Error Log
Register Name: QB_DERR Register Offset: F88
Bits Function
31–24 QDERR
23–16 QDERR
15–08 QDERR
07–00 QDERR
QB_DERR Description
Name Type Reset By Reset
State Function
QDERR[31:0] R G_RST 0 QBus Data Error Log
Appendix A: Registers
QSpan II User Manual294 May 16, 20 13
Table 150: I20 Outbound Post_List Interrupt Status Register
Register Name: I2O_OPIS Register Offset: 030
Bits Function
31–24 Reserved
23–16 Reserved
15–08 Reserved
07–00 Reserved OP_ISR Reserved
I2O_OPIS Description
Name Type Reset By Reset
State Function
OP_ISR R/W G_RST 0 Outbound Post_List Interrupt Service Re quest
0 = Outbound Post_List FIFO is empty
1 = Outbound Post_List FIFO is not empty. The value of
the interrupt mask bit does not affect this bit.
Appendix A: Registers
QSpan II User Manual 295
May 16, 2013
Table 151: I20 Outbound Post_List Interrupt Mask Register
Register Name: I2O_OPIM Register Offset: 034
Bits Function
31–24 Reserved
23–16 Reserved
15–08 Reserved
07–00 Reserved OP_IM Reserved
I2O_OPIM Description
Name Type Reset By Reset
State Function
OP_IM R G_RST 1 Outbound Post_List Interrupt Mask
0 = Outbound Post_List Interrupt is enabled
1 = Outbound Post_List Interrupt is masked
Appendix A: Registers
QSpan II User Manual296 May 16, 20 13
Table 152: I2O Inbound Queue Register
Register Name: I2O_INQ Register Offset: 040
Bits Function
31–24 IN_Q
23–16 IN_Q
15–08 IN_Q
07–00 IN_Q
I2O_INQ Description
Name Type Reset By Reset
State Function
IN_Q[31:0] R/WP G_RST 0 I2O Inbound Queue
This register controls the access to the inbound queue. The
32-bit value written into this register is written by QSpan
II to the Inbound Post_List FIFO which is located in Qbus
memory at the address specified by the Inbound Post_List
Top Pointer. Accesses to this register result in retries from
the time of the PCI write until the write completes on the
QBus.
PCI reads to this register return data from the Inbound
Free_List FIFO, located in Qbus memory on the QBus at
the address specified by the Inbound Free_List Bottom
Pointer. A value of 0xFFFF FFFF is returned if the
Inbound Free_List FIFO is empty.
Appendix A: Registers
QSpan II User Manual 297
May 16, 2013
Table 153: I2O Outbound Queue Register
Register Name: I2O_OUTQ Register Offset: 044
Bits Function
31–24 OUT_Q
23–16 OUT_Q
15–08 OUT_Q
07–00 OUT_Q
I2O_OUTQ Description
Name Type Reset By Reset
State Function
OUT_Q[31:0] R/WP G_RST 0 I2O Outbound Queue
This register controls the host processor access to the
outbound queue. The 32-bit value written into this register
is written by
QSpan II to the Outbound Post_List FIFO which is located
in Qbus memory at the address specified by the Outbound
Post_List Top Pointer. Accesses to this register result in
retries from the time of the PCI write until the write
completes on the QBus.
PCI reads to this register return data from the Outbound
Free_List FIFO, located in Qbus memory on the QBus at
the address specified by the Outbound Free_List Bottom
Pointer. A value of 0xFFFF FFFF is returned if the
Outbound Free_List FIFO is empty.
Appendix A: Registers
QSpan II User Manual298 May 16, 20 13
QSpan II User Manual 299
May 16, 2013
Appendix B: Timing
This appendix provides timing information for the QBus interface. PCI interface timing
is not detailed since the QSpan II is PCI 2.2 Specification compliant. T iming parameters
for all processors are listed first, followed by the timing diagrams.
The following topics are discussed:
“Ti ming Parameters” on page 300
“Wait State Insertion — QBus Slave Module” on page 314
“Timing Diagrams” on page 315
B.1 Overview
The timing tables described in this appendix include the following:
Table 154, “Timing Parameters for MC68360 Interface” on page 301
Table 155, “Timing Parameters for MPC860 Interface” on page 306
Table 156, “Timing Parameters for M68040 Interface” on page 310
Table 157, “Timing Parameters for Interrupts and Resets” on page 313
Table 158, “Timing Parameters for Reset Options” on page 313
The sets of diagrams described in this appendix include the following:
“QBus Interface — MC68360” on page 315
“QBus Interface — MPC860” on page 330
“QBus Interface — M68040” on page 345
“Interrupts and Resets” on page 355
“Reset Options” on page 357
Appendix B: Timing
QSpan II User Manual300 May 16, 20 13
B.2 Timing Parameters
Test conditions for timing parameters in Table 154 to Table 158 are:
Test Conditions for 3.3V
Commercial (C): 0ºC to 70ºC, 3.3V±5%
Industrial (I): -40ºC to 85ºC, 3.3V±5%
Use the following figure as a reference when reading the timing diagrams in this
appendix.
Figure 24: Refere nce Voltages for AC Timing Specification
In order to condense the diagrams and tables, certain multifunctional
QBus signals are presented in their bus specific forms (for example,
DSACK1_/TA_ is referred to as TA_ in th e MPC860 and M68040
sections).
DC
D
C
A
B
A
B
A - Max Output Delay
B - Min Output Hold
C - Min Input Setup
D - Min Input Hold
0ns 50ns 100ns 150ns
QCLK
Outputs
Output
Inputs
Input
2.0V 0.8V 0.8V 2.0V
2.0V
0.8V
2.0V
0.8V
2.0V
0.8V
2.0V
0.8V
2.0V
0.8V
2.0V
0.8V
2.0V
0.8V
2.0V
0.8V
Appendix B: Timing
QSpan II User Manual 301
May 16, 2013
Table 154: Timing Parameters for MC68360 Interface
Timing
Parameter Description
Frequency/Te mperature Options
Units Note
50Cx/50Ix 40Cx
Min Max Min Max
t200 QCLK Frequency - 33 - 25 MHz -
t201 Period 30 - 40 - ns -
t202 Clock Pulse Width (Low) 14 - 19 - ns -
t204 Clock Pulse Width (High) 14 - 19 - ns -
t205 Clock Rise Time (tr) -2-2ns-
t206 Clock Fall Time (tf)-2-2ns-
t210a A asserted from QCLK (positive
edge) - 9.6 - 10.7 ns 2
t210b BERR_ asserted from QCLK
(positive edge) - 9.2 - 10.2 ns 2
t210c DSACK0_, DSACK1_ asserted
from QCLK (positive edge) - 9.4 - 10.4 ns 2
t210d HALT_ asserted from QCLK
(positive edge) -8.9-9.9ns2
t210e R/W_ asserted from QCLK
(positive edge) -8-8.9ns2
t210f SIZ asserted from QCLK (positive
edge) -7.9-8.8ns2
t210g TC asserted from QCLK (positive
edge) -8.4-9.3ns2
t211a BGACK_ asse rted from QCLK
(positive edge) - 9.2 - 10.2 ns 1
t211b BR_ asserted from QCLK (positive
edge) -7.4-8.2ns2
t212a DSACK0_, DSACK1_ tristated
from QCLK (negative edge) - 9.4 - 10.4 ns -
t212b BERR_ tristated from QCLK
(negative edge) - 9.6 - 10.6 ns -
t212c HALT_ tristated from QCLK
(negative edge) - 9.1 - 10.1 ns -
t213 D asserted (slave reads) from
QCLK (negative edge) - 14.8 - 16.4 ns 1
Appendix B: Timing
QSpan II User Manual302 May 16, 20 13
t214 D tristated (slave reads) from
QCLK (positive edge) - 13.7 - 15.2 ns -
t215a AS_ asserted from QCLK (negative
edge) -8-8.9ns1
t215b DS_ asserted from QCLK (negative
edge) -7.8-8.7ns-
t216a AS_ tristated from QCLK (positive
edge) -7.9-8.8ns-
t216b DS_ tristated from QCLK
(positive edge) -8.1- 9ns-
t217a BERR_ setup to QCLK (negative
edge) 0-0-ns-
t217b BG_ setup to QCLK (negative
edge) -0.9 - -1.0 - ns -
t217c BGACK_ setup to QCLK (negative
edge) 0-0-ns-
t217d DSACK0_, DSACK1_ setup to
QCLK (negative edge) 0-0-ns-
t217e HALT_ setup to QCLK (negative
edge) 0-0-ns-
t218a BERR_ hold from QCLK (negative
edge) 0-0-ns-
t218b BG_ hold from QCLK (negative
edge) 0-0-ns-
t218c BGACK_ hold from QCLK
(negative edge) 1.4 - 1.5 - ns -
t218d DSACK0_, DSACK1_ hold from
QCLK (negative edge) 0-0-ns-
t218e HALT_ hold from QCLK (negative
edge) 0-0-ns-
t219a A setup to QCLK (negative edge) 7 - 7.8 - ns -
t219b AS_ setup to QCLK (negative edge) 3.4 - 3.8 - ns -
t219c CSPCI_ setup to QCLK (negative
edge) 2.8 - 3.1 - ns -
Table 154: Timing Parameters for MC68360 Interface (Continued)
Timing
Parameter Description
Frequency/Te mperature Options
Units Note
50Cx/50Ix 40Cx
Min Max Min Max
Appendix B: Timing
QSpan II User Manual 303
May 16, 2013
t219d CSREG_ setup to QCLK (negative
edge) 7 - 7.8 - ns -
t219e IMSEL setup to QCL K (negative
edge) 3 - 3.3 - ns -
t219f R/W_ setup to QCLK (n eg a t iv e
edge) 3.2 - 3.6 - ns -
t219g SIZ setup to QCLK (negative edge) 6.6 - 7.3 - ns -
t219h TC setup to QCLK (negative edge) 4.5 - 5 - ns -
t220a A hold from QCLK (negative edge) 0.1 - 0.1 - ns -
t220b AS_ hold from QCLK (negative
edge) 0.5 - 0.5 - ns -
t220c CSPCI_ hold from QCLK (negative
edge) 0.9 - 1 - ns -
t220d CSREG_ hold from QCLK
(negative edge) 1.5 - 1.7 - ns -
t220e IMSEL hold from QCLK (negative
edge) 0-0-ns-
t220f R/W_ hold from QCLK (negative
edge) 0.9 - 1 - ns -
t220g SIZ hold from QCLK (negative
edge) 0-0-ns-
t220h TC hold from QCLK (negative
edge) 0-0-ns-
t221 D setup (master reads) to QCL K
(negative edge) 0-0-ns-
t222 D hold (master reads) from QCLK
(negative edge) 2.1 - 2.3 - ns -
t223 D setup (slave writes) to QCLK
(positive edge) 0-0-ns-
t224 D hold (slave writes) from QCLK
(positive edge) 1.8 - 2 - ns -
t225 D asserted (master writes) from
QCLK (positive edge) - 9.8 - 10.9 ns 1
Table 154: Timing Parameters for MC68360 Interface (Continued)
Timing
Parameter Description
Frequency/Te mperature Options
Units Note
50Cx/50Ix 40Cx
Min Max Min Max
Appendix B: Timing
QSpan II User Manual304 May 16, 20 13
t226 D tristated (master writes) from
QCLK (positive edge) 3.9 9.8 4.3 10.9 ns -
t234 BGACK_ tristated from QCLK
(negative edge) - 9.2 10.2 ns -
t235a BGACK_ negated from QCLK
(positive edge) 3.2 7.4 3.6 8.2 ns 2
t235b BR_ negated from QCLK (positive
edge) 3.2 7.3 3.5 8.1 ns 1
t236a A tristated or negated from QCLK
(positive edge) 3.8 9.6 4.3 10.7 ns 1
t236b BERR_ tristated or negated from
QCLK (positive edge) 3.7 9.2 4.1 10.2 ns 1
t236c DSACK0_, DSACK1_ tristated or
negated from QCLK (positive edge) 3.3 9.4 3.7 10.4 ns 1
t236d HALT_ tristated or negated from
QCLK (positive edge) 3.5 8.9 3.9 9.9 ns 1
t236e R/W_ tristated or negated from
QCLK (positive edge) 3.2 8 3.6 8.9 ns 1
t236f SIZ tristated or negated from QCLK
(positive edge) 3.1 7.9 3.5 8.8 ns 1
t236g TC tristated or negated from QCLK
(positive edge) 3.3 8.4 3.7 9.3 ns 1
t250 DREQ_ asserted (or negated) from
QCLK (negative edge) 4 9.3 4.4 10.4 ns 2
t251 D asserted (valid) from DACK_
(negative edge) - 12.5 - 13.9 ns 1
t252 D tristated from DACK_ (positive
edge) 3.9 12.5 4.4 13.9 ns -
t253a AS_ setup to QCLK (negative edge) 3.4 - 3.8 - ns -
t253b CSPCI_ setup to QCLK (negative
edge) 2.8 - 3.1 - - -
t254 DACK_ setup to QCLK (negative
edge) 2.5 - 2.8 - ns -
Table 154: Timing Parameters for MC68360 Interface (Continued)
Timing
Parameter Description
Frequency/Te mperature Options
Units Note
50Cx/50Ix 40Cx
Min Max Min Max
Appendix B: Timing
QSpan II User Manual 305
May 16, 2013
1. Minimum output hold time specified for load of 10 pF. Maximum output delay specified for load of 50 pF.
t255 DSACK0_, DSACK1_ setup to
QCLK (negative edge) 0.6 - 0.6 - ns -
t256 BERR_ setup to QCLK (negative
edge) 3 - 3.3 - ns -
t257 HALT_ setup to QCLK (negative
edge) 2 - 2.2 - ns -
t258 D setup to QCLK (negative edge) 0 - 0 - n s -
t259a AS_ hold from QCLK (negative
edge) 0.5 - 0.5 - ns -
t259b CSPCI_ hold from QCLK (negative
edge) 0.9 - 1 - ns -
t259c D hold from QCLK (negative edge) 2.1 - 2.4 - ns -
t259d DACK_ hold from QCLK (negative
edge) 0.6 - 0.7 - ns -
t259e DSACK0_, DSACK1_ hold from
QCLK (negative edge) 0.7 - 0.8 - ns -
t259f BERR_ hold from QCLK (negative
edge) 0.5 - 0.6 - ns -
t259g HALT_ hold from QCLK (negative
edge) 1.2 - 1.3 - ns -
t260 DONE_ setup to QCLK (negative
edge) 0.1 - 0.1 - ns -
t261 DONE_ hold from QCLK (negative
edge) 1.8 - 2 - ns -
t262a AS_ negated from QCLK (negative
edge) 3.4 8 3.8 8.9 ns 1
t262b DS_ negated from QCLK (negative
edge) 3.4 7.8 3.8 8.7 ns 1
Table 154: Timing Parameters for MC68360 Interface (Continued)
Timing
Parameter Description
Frequency/Te mperature Options
Units Note
50Cx/50Ix 40Cx
Min Max Min Max
Appendix B: Timing
QSpan II User Manual306 May 16, 20 13
2. Minimum output hold time specified for load of 10 pF. Maximum output delay specified for load of 35 pF.
During IDMA fast termination cycles the maximum MC68360 QCLK
frequency is 30 MHz. This applies to every variant of QSpan II.
Table 155: Timing Parameters for MPC860 Interface
Frequency/Temperature Options
Units Note
Timing
Parameter Description
50Cx/50Ix 40Cx
Min Max Min Max
t300 QCLK Frequency - 50 - 40 MHz -
t301 Period 20 - 25 - ns -
t302 Clock Pulse Width (Low) 8 - 10 - ns -
t304 Clock Pulse Width (High) 8 - 10 - ns -
t305 Clock Rise Time (tr)-2-2ns-
t306 Clock Fall Time (tf)-2-2ns-
t310a A asserted from QCLK (positive edge) - 8.9 - 10.7 ns 1
t310b BB_ asserted from QCLK (positive edge) - 8.2 - 9.8 ns 1
t310c BURST_ asserted from QCLK (positive
edge) -7.5-9.6ns1
t310d R/W_ asserted from QCLK (positive edge) - 6.9 - 8.9 ns 1
t310e SIZ asserted from QCLK (positive edge) - 6.9 - 8.8 ns 1
t310f TA_ asserted from QCLK (positive edge) - 8.2 - 10.5 ns 1
t310g TC asserted from QCLK (positive edge) - 7.3 - 9.3 ns 1
t310h TEA_ asserted from QCLK (positive edge) - 8.0 - 9.6 ns 1
t310i TRETRY_ asserted from QCLK (positive
edge) -8-10.2ns1
t310j TS_ asserted from QCLK (positive edge) - 7.3 - 9.4 ns 1
t310k BDIP_ asserted from QCLK (positive edge) - 7.6 - 9.8 ns 1
t311 BR_ asserted (or negated) from QCLK
(positive edge) 2.8 6.4 3.6 8.2 ns 2
t312a BB_ tristated from QCLK (negative edge) - 8 - 10.2 ns -
t312b TS_ tristated from QCLK (negative edge) - 7.5 - 9.6 ns -
t313a BB_ setup to QCLK (positive edge) 4.5 - 5.8 - ns -
Appendix B: Timing
QSpan II User Manual 307
May 16, 2013
t313b BDIP_ setup to QCLK (positive edge) 2.4 - 3 - ns -
t313c BG_ setup to QCLK (positive edge) 4.7 - 6 - ns -
t313d BURST_ setup to QCLK (positive edge) 4.4 - 5.6 - ns -
t313e D setup to QCLK (positive edge) 6 - 7.7 - ns 3
t313f IMSEL setup to QCLK (positive edge) 3.9 - 5 - ns -
t313g TA_ setu p to QCLK (positive edge) 5 .5 - 7 - ns -
t313h TEA_ setup to QCLK (positive edge) 6 - 7.6 - ns -
t313i TRETRY_ setup to QCLK (positive edge) 5.3 - 6.8 - ns -
t314 D valid (slave reads) from QCLK (positive
edge) 3 9.5 3.9 12.2 ns 1,3
t315a A_ hold from QCLK (positive edge) 0.7 - 0.8 - ns -
t315b BB_ hold from QCLK (positive edge) 0 - 0 - ns -
t315c BDIP_ hold from QCLK (positive edge) 0.6 - 0.7 - ns -
t315d BG_ hold from QCLK (positive edge) 0 - 0 - ns -
t315e BURST_ hold from QCLK (positive edge) 0.5 - 0.6 - ns -
t315f CSPCI_ hold from QCLK (positive edge) 0.4 - 0.5 - ns -
t315g CSREG_ hold from QCLK (positive edge) 0.5 - 0.6 - ns -
t315h D hold from QCLK (positive edge) 1.6 - 2 - ns 3
t315i IMSEL hold from QCLK (positive edge) 0 - 0 - ns -
t315j R/W_ hold from QCLK (positive edge) 0.6 - 0.7 - ns -
t315k SIZ hold from QCLK (positive edge) 0.9 - 1.1 - ns -
t315l TA_ hold from QCLK (p ositive edge) 0.2 - 0.2 - ns -
t315m TC hold from QCLK (positive edge) 1.8 - 2.2 - ns -
t315n TEA_ hold from QCLK (positive edge) 0.3 - 0.4 - ns -
t315o TRETRY_ hold from QCLK (positive edge) 0.3 - 0.3 - ns -
t315p TS_ hold from QCLK (positive edge) 0.6 - 0.8 - ns -
t316 D tristated from QCLK (positive edge) 3.4 12.0 4.3 15.2 ns 3
t317 D enabled from QCLK (positive edge) - 12.0 - 15.2 ns 3
Table 155: Timing Parameters for MPC860 Interface (Continued)
Frequency/Temperature Options
Units Note
Timing
Parameter Description
50Cx/50Ix 40Cx
Min Max Min Max
Appendix B: Timing
QSpan II User Manual308 May 16, 20 13
t334 D valid (master writes) from QCLK
(positive edge) -8.5-10.9ns1,3
t335a TA_ tristated from QCLK (negative edge) - 8.2 - 10.5 ns -
t335b TEA_ tristated from QCLK (negative edge) - 8.1 - 10.4 ns -
t335c TRETRY_ tristated from QCLK (negative
edge) -7.8-10ns-
t336a A negated from QCLK (positive edge) - 8.4 - 10.7 ns 1
t336b BB_ negated from QCLK (positive edge) 2.7 6.4 3.5 8.1 ns 1
t336c BURST_ negated from QCLK (positive
edge) -7.8-10ns1
t336d R/W_ negated from QCLK (positive edge) - 6.9 - 8.9 ns 1
t336e SIZ negated from QCLK (positive edge) - 6.9 - 8.8 ns 1
t336f TA_ negated from QCLK (positive edge) 2.8 7.3 3.7 9.3 ns 1
t336g TC negated from QCLK (positive edge) - 8.2 - 10.5 ns 1
t336h TEA_ negated from QCLK (positive edge) 3.2 9.3 4 .1 11.9 ns 1
t336i TRETRY_ negated from QCLK (po sitive
edge) 3 8.1 3.8 10.3 ns 1
t336j TS_ negated from QCLK (positive edge) 3.5 6.4 4 .6 8.2 ns 1
t336k BDIP_ negated from QCLK (positive edge) - 7.8 - 10 ns 1
t337a A setup to QCLK (positive edge) 5.3 - 6.8 - ns -
t337b CSPCI_ setup to QCLK (positive edge) 3.4 - 4.4 - ns -
t337c CSREG_ setup to QCLK (positive edge) 5.3 - 6.8 - ns -
t337d R/W_ setup to QCLK (positive edge) 3.6 - 4.6 - ns -
t337e SIZ setup to QCLK (positive edge) 4.9 - 6.3 - ns -
t337f TC setup to QCLK (positive edge) 5 - 7.1 - ns -
t337g TS_ setup to QCLK (positive edge) 3.7 - 4.7 - ns -
t350 DREQ_ asserted (or negated) from QCLK
(positive edge) 3.7 9.2 4.8 11.8 ns 2
t351 D asserted (valid) from SDACK_ (negative
edge) 10.8 - 13.9 ns 1,3
Table 155: Timing Parameters for MPC860 Interface (Continued)
Frequency/Temperature Options
Units Note
Timing
Parameter Description
50Cx/50Ix 40Cx
Min Max Min Max
Appendix B: Timing
QSpan II User Manual 309
May 16, 2013
1. Minimum output hold time specified for load of 10 pF. Maximum output delay specified for load of 50 pF.
2. Minimum output hold time specified for load of 10 pF. Maximum output delay specified for load of 35 pF.
3. QSpan II’s DP[3:0] signals have the same timing as the data bus (D[31:0]).
t352 D tristated from TA_ (positive edge) 4.1 12.4 5.3 15.9 ns 3
t353a CSPCI_ setup to QCLK (positive edge) 3.5 - 4.4 - ns -
t353b TS_ setup to QCLK (positive edge) 4.1 - 5.2 - ns -
t354 SDACK_ setup to QCLK (positive edge) 0 - 0 - ns -
t355a TA_ setu p to QCLK (positive edge) 3.1 - 3 .9 - ns -
t355b TEA_ setup to QCLK (positive edge) 3.5 - 4.5 - ns -
t356 TRETRY_ setup to QCLK (positive edge) 3.1 - 4 - ns -
t357a TA_ asserted to SDACK_ (positive edge) 2 - 2 - ns -
t357b TEA_ asserted to SDACK_ (positive edge) 2 - 2 - ns -
t357c TRETRY_ asserted to SDACK_ (positive
edge) 2 - 2 - ns -
t359a CSPCI_ hold from QCLK (positive edge) 0.8 - 1 - ns -
t359b D hold from QCLK (positive edge) 1.6 - 2 - ns -
t359c SDACK_ hold from QCLK (positive edge) 0 - 0 - ns -
t359d TA_ hold from QCLK (p ositive edge) 0.7 - 0.8 - ns -
t359e TEA_ hold from QCLK (positive edge) 0 - 0 - ns -
t359f TRETRY_ hold from QCLK (positive edge) 0 - 0 - ns -
t359g TS_ hold from QCLK (positive edge) 0.2 - 0.2 - ns -
t360 TC setup to QCLK (positive edge) 5.0 - 7.1 - - -
t361 TC hold from QCLK (positive edge) 0.4 - 0 .4 - - -
Table 155: Timing Parameters for MPC860 Interface (Continued)
Frequency/Temperature Options
Units Note
Timing
Parameter Description
50Cx/50Ix 40Cx
Min Max Min Max
Appendix B: Timing
QSpan II User Manual310 May 16, 20 13
Table 156: Timing Parameters for M68040 Interface
Timing
Parameter Description
40Cx
Units NoteMin Max
t400 QCLK Frequency - 40 MHz -
t401 Period 25 - ns -
t402 Clock Pulse Width (Low) 12 - ns 3
t404 Clock Pulse Width (H igh) 10 - ns 3
t405 Clock Rise T ime (tr)-3ns-
t406 Clock Fall Time (tf)-3ns-
t409a TA_ tristated from QCLK (negative edge) - 11.4 ns -
t409b TEA_, tristated from QCLK (negative edge) - 10.4 ns -
t410a A asserted from QCLK (positive edge) - 10.7 ns 1
t410b BB_ asserted from QCLK (positive edge) - 9.8 ns 1
t410c R/W_ asserted from QCLK (positive edge) - 8.9 ns 1
t410d SIZ asserted from QCLK (positive edge) - 8.8 ns 1
t410e TA_ asserted from QCLK (positive edge) - 11.4 ns 1
t410f TC asserted from QCLK (positive edge) - 9.3 ns 1
t410g TEA_ asserted from QCLK (positive edge) - 1 1.9 ns 1
t410h BURST_/TIP_ asserted from QCLK (positive edge) - 9.6 ns 1
t410i TS_ asserted from QCLK (positive edge) - 9.4 ns 1
t411 BR_ asserted from QCLK (positive edge) 3.6 8.2 ns 2
t412a BB_ tristated from QCLK (negative edge) - 10.2 ns -
t412b TS_ tristated from QCLK (negative edge) - 9.6 ns -
t413a BB_ setup to QCLK (positive edge) 5.8 - ns -
t413b BG_ setup to QCLK (positive edge) 6.0 - ns -
t413c D setup to QCLK (positive edge) 7.7 - ns -
t413d IMSEL setup to QCLK (positive edge) 5.0 - ns -
t413e TA_ setup to QCLK (positive edge ) 7.0 - ns -
t413f TEA_ setup to QCLK (positive edge) 7.6 - ns -
t413g BURST_/TIP_ setup to QCLK (positive edge) 5.6 - ns -
Appendix B: Timing
QSpan II User Manual 311
May 16, 2013
t414 D valid from QCLK (positive edge) (master writes) 4.3 10.9 ns 1
t415a A hold from QCLK (positive edge) 0.8 - ns -
t415b BB_ hold from QCLK (positive edge) 0 - ns -
t415c BG_ hold from QCLK (positive edge) 0 - ns -
t415d BURST_/TIP_ hold from QCLK (positive edge) 0.6 - ns -
t415e CSPCI_ hold from QCLK (positive edge) 0.5 - ns -
t415f CSREG_ hold from QCLK (positive edge) 0.6 - ns -
t415g D hold from QCLK (positive edge) 2.0 - ns -
t415h IMSEL hold from QCLK (positive edge) 0.0 - ns -
t415i R/W_ hold from QCLK (positive edge) 0.7 - ns -
t415j SIZ hold from QCLK (positive edge) 1.1 - ns -
t415k TA_ hold from QCLK (positive edge) 0.2 - ns -
t415l TC hold from QCLK (positive edge) 2.2 - ns -
t415m TEA_ hold from QCLK (positive edge) 0.4 - ns -
t415n TRETRY_ hold from QCLK (positive edge) 0.3 - ns -
t415o TS_ hold from QCLK (positive edge) 0.8 - ns -
t416 D tristated from QCLK (positive edge) 4.3 15.2 ns -
t417 D valid from QCLK (positive edge) (slave reads) - 12.2 ns 1
t418 D hold from QCLK (positive edge) 3.9 - ns -
t419a A setup to QCLK (positive edge) 6.8 - ns -
t419b CSPCI_ setup to QCLK (positive edge) 4.4 - ns -
t419c CSREG_ setup to QCLK (positive edge) 6.8 - ns -
t419d R/W_ setup to QCLK (positive edge) 4.6 - ns -
t419e SIZ setup to QCLK (positive edge) 6.3 - ns -
t419f TC setup to QCLK (positive edge) 6.4 - ns -
t419g TS_ setup to QCLK (positive edge) 4.7 - ns -
t436a A negated from QCLK (positive edge) - 10.7 ns 1
t436b BB_ negated from QCLK (positive edge) - 7.8 ns 1
Table 156: Timing Parameters for M68040 Interface (Continued)
Timing
Parameter Description
40Cx
Units NoteMin Max
Appendix B: Timing
QSpan II User Manual312 May 16, 20 13
1. Minimum output hold time specified for load of 10 pF. Maximum output delay specified for load of 50 pF.
2. Minimum output hold time specified for load of 10 pF. Maximum output delay specified for load of 35 pF.
3. Measured at 1.5 volts.
t436c R/W_ negated from QCLK (positive edge) - 8.8 ns 1
t436d SIZ negated from QCLK (positive edge) - 7.8 ns 1
t436e TA_ nega ted from QCLK (positive edge) 4.3 11.4 ns 1
t436f TC negated from QCLK (positive edge) - 9.3 ns 1
t436g TEA_ negated from QCLK (positive edge) 4.1 11.3 ns 1
t436h BURST_/TIP_ negated from QCLK (positive edge) - 9.9 ns 1
t436i TS_ negated from QCLK (positive edge) - 7.9 ns 1
Table 156: Timing Parameters for M68040 Interface (Continued)
Timing
Parameter Description
40Cx
Units NoteMin Max
Appendix B: Timing
QSpan II User Manual 313
May 16, 2013
Table 157: Timing Parameters for Interrupts and Resets
Timing
Parameter Description
3.3V
Units NoteMin Max
t001 RST# asserted to RESETO_ asserted - 10.8 ns -
t002 RST# negated to RESETO_ tristated - 10.8 ns -
t003 RESETO_ asserted from PCLK (rising edge) - 10.1 ns -
t004 RESETO_ tristated from PCLK (rising edge) - 10.1 ns -
t005 QINT_ asserted from PCLK (rising edge) - 10.7 ns -
t006 QINT_ tristated from PCLK (rising edge) - 10.7 ns -
Table 158: Timing Parameters for Reset Options
Timing
Parameter Description
All Parts
Units NoteMin Max
t007 SIZ[1] setup to RESETI_ or RST# (rising edge) 1 - ns 1
t008 TMODE[1] setup to RESETI_ or RST# (rising edge) 2.5 - ns 1
t009 TMODE[0] setup to RESETI_ or RST# (rising edge) 2.5 - ns 1
t010 BDIP_ setup to RESETI_ or RST# (rising edge) 2.0 - ns 1
t011 BM_EN setup to RESETI_ or RST# (rising edge) 1.5 - ns 1
t012 SDA setup to RESETI_ or RST# (rising edge) 2.25 - ns 1
t013 SIZ[1] hold from RESETI_ or RST# (rising edge) 1.75 - n s 1
t014 TMODE[1] hold from RESETI_ or RST# (rising edge) 2.75 - ns 1
t015 TMODE[0] hold from RESETI_ or RST# (rising edge) 2.75 - ns 1
t016 BDIP hold from RESETI or RST# (rising edge) 2.0 - ns 1
t017 BM_EN hold from RESETI_ or RST# (rising edge) 1.5 - ns 1
t018 SDA hold from RESETI_ or RST# (rising edge) 2.75 - ns 1
t019a RST# or RESETI_ pulse width (asserted) @ 25MHz 40 - ns -
t019b RST# or RESETI_ pulse width (asserted) @ 33MHz 30 - ns -
t019c RST# or RESETI_ pulse width (asserted) @ 50MHz 20 - ns -
t020 ENID setup to RESETI_ or RST# (rising edge) 2.5 - ns -
t021 ENID hold from RESETI_ or RST# (rising edge) 2.75 - ns -
t022 PCI_DIS setup to RESETI_ or RST# (rising edge) 2.5 - ns -
Appendix B: Timing
QSpan II User Manual314 May 16, 20 13
B.3 Wait State Insertion — QBus Slave Module
QSpan II as QBus slave inserts wait states as follows:
One wait state for all retried cycles
One wait state for burst writes
One wait states for single posted writes
Two wait states for complete delayed reads and writes
One wait state for complete delayed burst reads
See the following section for register accesses.
When the QBus processor is accessing the QSpan II’s registers, the maximum number
of retries the QSpan II asserts is two. The minimum response time for successful
(non-retried) QBus accesses from TS_ (or AS_) asserted to TA_ (or DSACKx_)
asserted is three QCLKs (including two wait states) for reads, and six for writes.
Use Figure 24 when reading the timing diagrams in this Appendix.
t023 PCI_DIS hold from RESETI_ or RST# (rising edge) 2.75 - ns -
t024 PCI_ARB_EN setup to RESETI_ or RST# (rising edge) 2.5 - ns -
t025 PCI_ARB_EN hold from RESETI_ or RST# (rising edge) 2.75 - ns -
1. These setup and hold times also apply to the falling edge of HS_HEALTHY_.
The following wait-state list does not apply to IDMA transfers.
Table 158: Timing Parameters for Reset Options (Continued)
Timing
Parameter Description
All Parts
Units NoteMin Max
Appendix B: Timing
QSpan II User Manual 315
May 16, 2013
B.4 Timing Diagrams
B.4.1 QBus Interface — MC68360
Figure 25: QCLK Input Timing — MC68360 CLKO1
The timing parameters t005 and t006 are measured between 0.8 and 2 Volts. The timing
parameters t005 and t006 can be found in Table 154 on page 301.
B.4.2 QBus Master Cycles — MC68360
Figur e 26 : QBus Arbitratio n — MC6836 0
This figure depicts timing in the case where the QSpan II requests ownership of the
QBus while another QBus master currently owns the bus (BB_/BGACK_ asserted by
the other master). QSpan II obtains own ership of the bus after the other master negates
BB_/BGACK_.
t204
t201 t204t202t202 t201
0ns 25ns 50ns 75ns
QCLK
t234
t235at211at218c
t218b
t235bt211b
t217c
t217b
t201t201
0ns 250ns 500ns
QCLK
BR_
BG_
BGACK_
Appendix B: Timing
QSpan II User Manual316 May 16, 20 13
Figure 27: Single Read — QSpan II as MC68360 Master
Wait states are not required by the QSpan II.
t216b
t262bt215b
t216a
t262at215a
t236et210e
t236ft210f
t236gt210g
t236at210a
t234
t235at211a
t235bt211b
t218a
t217a
t218d
t217d
t218d
t217d
t218e
t217e
t218a
t217a
t218d
t217d
t218d
t217d
t218d
t217d
t218d
t217d
t222
t221
t218bt217b
t201t201
a. Normal
b. Retry
c. Bus Error
0ns 250ns 500ns
QCLK
BR_
BG_
BGACK_
A[31:0]
TC[3:0]
SIZ[1:0]
D[31:0]
R/W_
DS_
AS_
DSACK0
_a
DSACK1
_a
BERR
_a
HALT
_a
DSACK0
_b
DSACK1
_b
BERR
_b
HALT
_b
DSACK0
_c
DSACK1
_c
BERR
_c
HALT
_c
Appendix B: Timing
QSpan II User Manual 317
May 16, 2013
Figure 28: Single Write — QSpan II as MC68360 Master
Wait states are not required by the QSpan II.
t216b
t262bt215b
t216a
t262at215a
t236et210e
t226t225
t236ft210f
t236gt210g
t236at210a
t234
t235at211a
t235bt211b
t218at217a
t218dt217d
t218dt217d
t218et217e
t218at217a
t218dt217d
t218dt217d
t218dt217d
t218dt217d
t218bt217b
t201t201
c. Bus Error
b. Retry
a. Normal
0ns 250ns 500ns
QCLK
BR_
BG_
BGACK_
A[31:0]
TC[3:0]
SIZ[1:0]
D[31:0]
R/W_
DS_
AS_
DSACK0_a
DSACK1_a
BERR_a
HALT_a
DSACK0_b
DSACK1_b
BERR_b
HALT_b
DSACK0_c
DSACK1_c
BERR_c
HALT_c
Appendix B: Timing
QSpan II User Manual318 May 16, 20 13
B.4.2.1 QBus Slave Cycles — MC68360
Figure 29: Delayed Single Read — QSpan II as MC6836 0 Slave
t212b
t236bt210b
t212a
t236ct210c
t212a
t236ct210c
t212c
t236dt210d
t212b
t236bt210b
t212a
t236ct210c
t212a
t236ct210c
t212a
t236ct210c
t212a
t236ct210c
t214t213
t220bt219b
t220ft219f
t220gt219g
t220ht219h
t220at219a
t220et219e
t220ct219c
t201t201
a. Normal
b. Retry
c. Bus Error
0ns 100ns 200ns 300ns 400ns
QCLK
CSPCI_
IMSEL
A[31:0]
TC[3:0]
SIZ[1:0]
D[31:0]
R/W_
AS_
DSACK0
_a
DSACK1
_a
BERR
_a
HALT
_a
DSACK0
_b
DSACK1
_b
BERR
_b
HALT
_b
DSACK0
_c
DSACK1
_c
BERR
_c
HALT
_c
Appendix B: Timing
QSpan II User Manual 319
May 16, 2013
Figure 30: Single Write — QSpan II as MC68360 Sl ave
t212b
t236bt210b
t212a
t236ct210c
t212a
t236ct210c
t212c
t236dt210d
t212b
t236bt210b
t212a
t236ct210c
t212a
t236ct210c
t212a
t236ct210c
t212a
t236ct210c
t220bt219b
t220ft219f
t224
t223
t220gt219g
t220ht219h
t220at219a
t220et219e
t220ct219c
t201t201
a. Norm al
b. Retry
c. Bus E r ror
0ns 100ns 200ns 300ns 400ns
QCLK
CSPCI_
IMSEL
A[31:0]
TC[3:0]
SIZ[1:0]
D[31:0]
R/W_
AS_
DSACK0
_a
DSACK1
_a
BERR
_a
HALT
_a
DSACK0
_b
DSACK1
_b
BERR
_b
HALT
_b
DSACK0
_c
DSACK1
_c
BERR
_c
HALT
_c
Appendix B: Timing
QSpan II User Manual320 May 16, 20 13
Figur e 31 : Re gister Read — QSpan II as MC68360 Slav e
t212c
t236dt210d
t212b
t236bt210b
t212a
t236ct210c
t212a
t236ct210c
t212a
t236ct210c
t212a
t236ct210c
t214t213
t219b
t220bt219b
t220ft219f
t220gt219g
t220ht219h
t220at219a
t220ct219d
t201t201
a. Normal
b. Retry
0ns 100ns 200ns 300ns
QCLK
CSREG_
A[31:0]
TC[3:0]
SIZ[1:0]
D[31:0]
R/W_
AS_
DSACK0_a
DSACK1_a
BERR_a
HALT_a
DSACK0_b
DSACK1_b
BERR_b
HALT_b
Appendix B: Timing
QSpan II User Manual 321
May 16, 2013
Figure 32: Register Write — QSpan II as MC68360 Slave
t212c
t236dt210d
t212b
t236bt210b
t212a
t236ct210c
t212a
t236ct210c
t212a
t236ct210c
t212a
t236ct210c
t219b
t220bt219b
t220ft219f
t224t223
t219g
t220ht219h
t220at219a
t220dt219d
t220gt201t201
a.Normal
b.Retry
0ns 100ns 200ns 300ns
QCLK
CSREG_
A[31:0]_
TC[3:0]
SIZ[1:0]
D[31:0]
R/W_
AS_
DSACK0_a
DSACK1_a
BERR_a
HALT_a
DSACK0_b
DSACK1_b
BERR_b
HALT_b
Appendix B: Timing
QSpan II User Manual322 May 16, 20 13
B.4.2.2 QBus IDMA Cycles — MC68360
Figure 33: MC68360 DREQ_ Timing
Terminology
Standard termination is used in the following figures in contrast to fast termination.
Normal termination as opposed to abnormal terminations, such as bus errors and
retries. Thus, some standard terminations are abnormal terminations (for example, bus
errors with non-fast termination).
Table 159: Directiona of QBus Signals During MC68360 IDMA Cycles
a. I = Input; O = Output; N/A = Not Applicable.
Signal
Single Address Dual Address
Standard Termination Fast Termination Standard Termination Fast Termination
CSPCI_ I
(negated) I
(negated) I
(asserted) I
(asserted)
AS_ IIII
D I (write)/O (read) I (write)/O (read) I (write)/O (read) I (write)/O (read)
DACK_ IIII
DONE_ IIII
DREQ_ OOOO
DSACK0_b
b. DSACK0_ is not applicable to IDMA transfers when the QBus is a 16-bit port.
I N/AON/A
DSACK1_ I N/AON/A
BERR_ I N/A N/A N/A
HALT_ I N/A N/A N/A
t250t250
t201t201
0ns 100ns 200ns 300ns 400ns
QCLK
DREQ_
Appendix B: Timing
QSpan II User Manual 323
May 16, 2013
Figure 34: MC68360 IDMA Read — Single Address, Standard Terminations
A[31:0] is depicted for completeness. It is not examined by t he QS pan II d uring IDMA
transfers; however, it can be used to drive CSPCI_. If the Port16 bit of IDMA_CS is
disabled, DSACK0_ is not asserted. CSPCI_ is negated during single address IDMA
cycles.
t252t251
t259gt257
t259ft256
t259et255
t259et255
t259gt257
t259ft256
t259et255
t259et255
t259gt257
t259ft256
t259et255
t259et255
t259dt254
t259at253a
t259bt253b
t201t201
a. Normal
b. Bus Error
c. Retry
0ns 50ns 100ns 150ns 200ns 250ns
QCLK
CSPCI_
AS_
A[31:0]
D[31:0]
DACK_
DONE_
DSACK0_a
DSACK1_a
BERR_a
HALT_a
DSACK0_b
DSACK1_b
BERR_b
HALT_b
DSACK0_c
DSACK1_c
BERR_c
HALT_c
Appendix B: Timing
QSpan II User Manual324 May 16, 20 13
Figure 35: MC68360 IDMA Write — Single Address, Standard Terminations
t259gt257
t259ft256
t259et255
t259et255
t259gt257
t259ft256
t259et255
t259et255
t259gt257
t259ft256
t259et255
t259et255
t259dt254
t259c
t258
t259at253a
t259bt253b
t201t201
a. Norm al
b. Bus Error
c. Retry
0ns 50ns 100ns 150ns 200ns 250ns
QCLK
CSPCI_
AS_
A[31:0]
D[31:0]
DACK_
DONE_
DSACK0_a
DSACK1_a
BERR_a
HALT_a
DSACK0_b
DSACK1_b
BERR_b
HALT_b
DSACK0_c
DSACK1_c
BERR_c
HALT_c
Appendix B: Timing
QSpan II User Manual 325
May 16, 2013
Figure 36: MC68360 IDMA Read — Single Address, Fast Termination
During IDMA fast termination cycles the maximum MC68360 QCLK frequency is
30 MHz.
Figure 37: MC68360 IDMA Write — Single Address, Fast Terminatio n
t252t251
t259dt254
t259a
t253a
t259bt253b
t201t201
0ns 25ns 50ns 75ns 100ns 125ns
QCLK
CSPCI_
AS_
A[31:0]
D[31:0]
DACK_
DONE_
t259d
t254
t259c
t258
t259a
t253a
t259bt253b
t201t201
0ns 25ns 50ns 75ns 100ns 125ns
QCLK
CSPCI_
AS_
A[31:0]
D[31:0]
DACK_
DONE_
Appendix B: Timing
QSpan II User Manual326 May 16, 20 13
Figure 38: MC68360 IDMA Read — Dual Address, Standard Termination
QSpan II does not issue retries or bus errors during dual address IDMA cycles.
t212a
t236ct210c
t212a
t236ct210c
t252t251
t259dt254
t259at253a
t259bt253b
t201t201
0ns 50ns 100ns 150ns 200ns 250ns
QCLK
CSPCI_
AS_
A[31:0]
D[31:0]
DACK_
DONE_
DSACK0_
DSACK1_
Appendix B: Timing
QSpan II User Manual 327
May 16, 2013
Figure 39: MC68360 IDMA Write — Dual Address, Standard Termination
t212a
t236ct210c
t212a
t236ct210c
t259dt254
t259c
t258
t259at253a
t259bt253b
t201t201
0ns 50ns 100ns 150ns 200ns 250ns
QCLK
CSPCI_
AS_
A[31:0]
D[31:0]
DACK_
DONE_
DSACK0_
DSACK1_
Appendix B: Timing
QSpan II User Manual328 May 16, 20 13
Figure 40: MC68360 IDMA Read — Dual Address, Fast Termination
During IDMA fast termination cycles the maximum MC68360 QCLK frequency is
30 MHz.
t252t251
t259d
t254
t259a
t253a
t259bt253b
t201t201
0ns 25ns 50ns 75ns 100ns 125ns
QCLK
CSPCI_
AS_
A[31:0]
D[31:0]
DACK_
DONE_
Appendix B: Timing
QSpan II User Manual 329
May 16, 2013
Figure 41: MC68360 IDMA Read — Dual Address, Fast Termination
t259d
t254
t259c
t258
t259a
t253a
t259bt253b
t201t201
0ns 25ns 50ns 75ns 100ns 125ns
QCLK
CSPCI_
AS_
A[31:0]
D[31:0]
DACK_
DONE_
Appendix B: Timing
QSpan II User Manual330 May 16, 20 13
B.4.3 QBus Interface — MPC860
B.4.3.1 QBus Master Cycles — MPC860
Figur e 42 : QB us Arbitratio n — MPC860
This figure depicts timing in the case where the QSpan II requests ownership of the
QBus while another QBus master currently owns the bus (BB_/BGACK_ asserted by
the other master). QSpan II obtains own ership of the bus after the other master negates
BB_/BGACK_.
t312a
t336b
t310b
t311t311
t315bt313a
t315dt313c
t301t301
0ns 250ns 500ns
QCLK
BR_
BG_
BB_
Appendix B: Timing
QSpan II User Manual 331
May 16, 2013
Figure 43: Single Read — QSpan II as MPC860 Master
t312b
t336jt310j
t336dt310d
t336gt310g
t336et310e
t336ct310c
t336at310a
t312a
t336bt310b
t311t311
t315n
t313h
t315o
t313i
t315l
t313g
t315h
t313e
t315dt313c
t301t301
a. Normal
b. Retry
c. Bus Error
0ns 100ns 200ns 300ns
QCLK
BR_
BG_
BB_
A[31:0]
BURST_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TRETRY_a
TA_b
TEA_b
TRETRY_b
TA_c
TEA_c
TRETRY_c
Appendix B: Timing
QSpan II User Manual332 May 16, 20 13
Figure 44: Single Write — QSpan II as MPC860 Master
t316t334
t312b
t336jt310j
t336dt310d
t336gt310g
t336et310e
t336ct310c
t336at310a
t312a
t336bt310b
t311t311
t315n
t313h
t315o
t313i
t315l
t313g
t315dt313c
t301t301
a. Normal
b. Retry
c. Bus Error
0ns 100ns 200ns 300ns
QCLK
BR_
BG_
BB_
A[31:0]
BURST_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TRETRY_a
TA_b
TEA_b
TRETRY_b
TA_c
TEA_c
TRETRY_c
Appendix B: Timing
QSpan II User Manual 333
May 16, 2013
Figure 45: Burst Read — QSpan II as MPC860 Master
t312b
t336jt310j
t336dt310d
t336gt310g
t336et310e
t336kt310k
t336ct310c
t336at310a
t312a
t336bt310b
t311t311
t315n
t313h
t315o
t313i
t315lt313g
t315h
t313e
t315h
t313e
t315h
t313e
t315h
t313e
t315dt313c
t301t301
a. Normal
b. Retry
c. Bus Error
0ns 100ns 200ns 300ns 400ns
QCLK
BR_
BG_
BB_
A[31:0]
BURST_
BDIP_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TRETRY_a
TA_b
TEA_b
TRETRY_b
TA_c
TEA_c
TRETRY_c
Appendix B: Timing
QSpan II User Manual334 May 16, 20 13
Figure 46: Aligned Burst Write — QSpan II as MPC860 Master
t316t334t334t334t334
t312b
t336jt310j
t336dt310d
t336gt310g
t336et310e
t336kt310k
t336ct310c
t336at310a
t312a
t336bt310b
t311t311
t315n
t313h
t315o
t313i
t315lt313g
t315dt313c
t301t301
a. Normal
b. Retry
c. Bus Error
0ns 100ns 200ns 300ns 400ns
QCLK
BR_
BG_
BB_
A[31:0]
BURST_
BDIP_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TRETRY_a
TA_b
TEA_b
TRETRY_b
TA_c
TEA_c
TRETRY_c
Appendix B: Timing
QSpan II User Manual 335
May 16, 2013
B.4.3.2 QBus Slave Cycle — MPC860
Figure 47: Single Read — QSpan II as MPC860 Slave
t335b
t336ht310h
t335c
t336it310i
t335a
t336ft310f
t316
t314
t314
t315p
t337g
t315jt337d
t315mt337f
t315kt337e
t315et313d
t315it313f
t315ft337b
t315at337a
t301t301
a. Normal
b. Retry
c. Bus Error
0ns 50ns 100ns 150ns 200ns 250ns
QCLK
A[31:0]
CSPCI_
IMSEL
BURST_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TRETRY_a
TA_b
TEA_b
TRETRY_b
TA_c
TEA_c
TRETRY_c
Appendix B: Timing
QSpan II User Manual336 May 16, 20 13
Figure 48: Single Write — QSpan II as MPC860 Slave
t335b
t336ht310h
t335c
t336it310i
t335a
t336ft310f
t315ht313e
t315p
t337g
t315jt337d
t315mt337f
t315kt337e
t315et313d
t315it313f
t315ft337b
t315at337a
t301t301
a. Normal
b. Retry
c. Bus Error
0ns 100ns 200ns 300ns
QCLK
A[31:0]
CSPCI_
IMSEL
BURST_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TRETRY_a
TA_b
TEA_b
TRETRY_b
TA_c
TEA_c
TRETRY_c
Appendix B: Timing
QSpan II User Manual 337
May 16, 2013
Figure 49: Burst Read — QSpan II as MPC860 Slave
Data 1 Data 2 Data 3 Data 4
t335a
t336ft310f
t316t314t314t314t314
t315p
t337g
t315jt337d
t315mt337f
t315kt337e
t315ct313b
t315et313d
t315it313f
t315f
t337b
t315at337a
t301t301
0ns 100ns 200ns 300ns
QCLK
A[31:0]
CSPCI_
IMSEL
BURST_
BDIP_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_
TEA_
TRETRY_
Appendix B: Timing
QSpan II User Manual338 May 16, 20 13
Figure 50: Burst Wr ite — QSpan II as MPC860 Slave
A minimum of one wait state is inserted if starting address is not aligned to a 16-byte
boundary.
DATA1 DATA2 DATA3 DATA4
t335a
t336ft310f
t315h
t313e
t315h
t313e
t315h
t313e
t315h
t313e
t315p
t337g
t315jt337d
t315mt337f
t315kt337e
t315ct313b
t315et313d
t315it313f
t315f
t337b
t315at337a
t301t301
0ns 50ns 100ns 150ns 200ns 250ns
QCLK
A[31:0]
CSPCI_
IMSEL
BURST_
BDIP_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_
TEA_
TRETRY_
Appendix B: Timing
QSpan II User Manual 339
May 16, 2013
Figur e 51: Register Read — QSpan II as MPC860 Slave
t335c
t336it310i
t335a
t336ft310f
t316
t314
t314t317
t315p
t337g
t315jt337d
t315mt337f
t315kt337e
t315et313d
t315gt337c
t315at337a
t301t301
a. Normal
b. Retry
0ns 100ns 200ns 300ns
QCLK
A[31:0]
CSREG_
BURST_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TRETRY_a
TA_b
TEA_b
TRETRY_b
Appendix B: Timing
QSpan II User Manual340 May 16, 20 13
Figure 52: Register Write — QSpan II as MPC860 Slave
Due to internal synchronization, the number of wait states may vary.
t335c
t336it310i
t335a
t336ft310f
t315ht313e
t315p
t315p
t337g
t315jt337d
t315mt337f
t315kt337e
t315et313d
t315gt337c
t315at337a
t301t301
a. Normal
b. Retry
0ns 100ns 200ns 300ns
QCLK
A[31:0]
CSREG_
BURST_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TRETRY_a
TA_b
TEA_b
TRETRY_b
Appendix B: Timing
QSpan II User Manual 341
May 16, 2013
B.4.3.3 QBus IDMA Cycles — MPC860
Figur e 53 : MPC 8 60 DREQ_ Timing
Table 160: Directiona of QBus Signals During MPC860 IDMA Cycles
a. I = Input; O = Output; N/A = Not Applicable.
Signal Single Address Dual Address
CSPCI_ I
(negated) I
(asserted)
TC_[3:0] N/A I
TS_ I I
D I (write)/
O (read) I (write)/
O (read)
SDACK_ I I
DONE_b
b. QSpan II ignores DONE_ during MPC860 IDMA cycles
N/A N/A
DREQ_ O O
TA_ I O
TEA_ I N/A
TRETRY_ I N/A
t350t350
t301t301
0ns 50ns 100ns 150ns 200ns 250ns
QCLK
DREQ_
Appendix B: Timing
QSpan II User Manual342 May 16, 20 13
Figure 54: MPC860 IDMA Read — Single Address
A[31:0] is depicted for completeness. It is not examined by the QSpan II durin g IDMA
transfer; however, it can be used to drive CSPCI_.
t352t351
t359et355b
t359f
t356
t359dt355a
t359ct354
t359gt353b
t359at353a
t359b
t301t301
a. Normal
b. Retry
c. Bus E r ror
0ns 50ns 100ns 150ns 200ns
QCLK
A[31:0]
CSPCI_
TS_
D[31:0]
SDACK_
TA_a
TEA_a
TRETRY_a
TA_b
TEA_b
TRETRY_b
TA_c
TEA_c
TRETRY_c
Appendix B: Timing
QSpan II User Manual 343
May 16, 2013
Figure 55: MPC860 IDMA Write — Single Address
A[31:0] is depicted for completeness. It is not examined by t he QS pan II d uring IDMA
transfers; however, it can be used to drive CSPCI_.
t359e
t355b
t359f
t356
t359d
t355a
t359c
t354
t359b
t313e
t359gt353b
t359at353a
t301t301
a. Normal
b. Retry
c. Bus Error
0ns 50ns 100ns 150ns 200ns
QCLK
A[31:0]
CSPCI_
TS_
D[31:0]
SDACK_
TA_a
TEA_a
TRETRY_a
TA_b
TEA_b
TRETRY_b
TA_c
TEA_c
TRETRY_c
Appendix B: Timing
QSpan II User Manual344 May 16, 20 13
Figure 56: MPC860 IDMA Read — Dual Address
A[31:0] is depicted for completeness. It is not examined by the QSpan II durin g IDMA
transfers; however, it can be used to drive CSPCI_.
t335at336ft310f
t352t351
t359ct354
t361t360
t359gt353b
t359at353a
t301t301
0ns 50ns 100ns 150ns 200ns
QCLK
A[31:0]
CSPCI_
TS_
TC[3:0]
D[31:0]
SDACK_
TA_
Appendix B: Timing
QSpan II User Manual 345
May 16, 2013
Figure 57: MPC860 IDMA Write — Dual Address
QSpan II does not issue retries or bus errors during dual address IDMA cycles
B.4.4 QBus Interface — M68040
Figure 58: QCLK Input Timing — M68040 BCLK
The timing parameters t405 and t406 are measured between 0.8 and 2 Volts. The timing
parameters t405 and t406 can be found in Table B.4
t335at336ft310f
t359c
t354
t359b
t313e
t361t360
t359g
t353b
t359at353a
t301t301
0ns 50ns 100ns 150ns 200ns
QCLK
A[31:0]
CSPCI_
TS_
TC[3:0]
D[31:0]
SDACK_
TA_
t404
t401 t404t402t402 t401
0ns 25ns 50ns 75ns 100ns 125ns
QCLK
Appendix B: Timing
QSpan II User Manual346 May 16, 20 13
B.4.4.1 QBus Master Cycles — M68040
Figure 59: QBus Arbitration — M68040
This figure depicts timing in the case where the QSpan II requests ownership of the
QBus while another QBus master currently owns the bus (BB_/BGACK_ asserted by
the other master). QSpan II obtains own ership of the bus after the other master negates
BB_/BGACK_.
t412a
t436b
t410b
t411t411
t415bt413a
t415ct413b
t401t401
0ns 250ns 500ns 750ns 1000ns
QCLK
BR_
BG_
BB_
Appendix B: Timing
QSpan II User Manual 347
May 16, 2013
Figure 60: Single Read — QSpan II as M68040 Master
t412b
t436it410i
t436ct410c
t436ft410f
t436dt410d
t436ht410h
t436at410a
t412a
t436bt410b
t411t411
t415m
t413f
t415m
t413f
t415k
t413e
t415k
t413e
t415g
t413c
t415ct413b
t401t401
a. Normal
b. Retry
c. Bus Error
0ns 100ns 200ns 300ns
QCLK
BR_
BG_
BB_
A[31:0]
BURST_/TIP_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TA_b
TEA_b
TA_c
TEA_c
Appendix B: Timing
QSpan II User Manual348 May 16, 20 13
Figure 61: Single Write — QSpan II as M68040 Master
t418
t416t414
t412b
t436it410i
t436ct410c
t436ft410f
t436dt410d
t436ht410h
t436at410a
t412a
t436bt410b
t411t411
t415m
t413f
t415m
t413f
t415k
t413e
t415k
t413e
t415ct413b
t401t401
a. Normal
b. Retry
c. Bus Error
0ns 100ns 200ns 300ns
QCLK
BR_
BG_
BB_
A[31:0]
BURST_/TIP_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TA_b
TEA_b
TA_c
TEA_c
Appendix B: Timing
QSpan II User Manual 349
May 16, 2013
B.4.4.2 QBus Slave Cycles — M68040
Figure 62: Single Read — QSpan II as M68040 Slave
t409b
t436gt410g
t409b
t436gt410g
t409a
t436et410e
t409a
t436et410e
t416
t417 t418
t415o
t419g
t415it419d
t415lt419f
t415jt419e
t415dt413g
t415ht413d
t415et419b
t415at419a
t401t401
a. Norm al
b. Retry
c. Bus Error
0ns 100ns 200ns 300ns
QCLK
A[31:0]
CSPCI_
IMSEL
BURST_/TIP_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TA_b
TEA_b
TA_c
TEA_c
Appendix B: Timing
QSpan II User Manual350 May 16, 20 13
Figure 63: Single Write — QSpan II as M68040 Slave
t409b
t436gt410g
t409b
t436gt410g
t409a
t436et410e
t409a
t436et410e
t415g
t413c
t415o
t419g
t415it419d
t415lt419f
t415jt419e
t415dt413g
t415ht413d
t415et419b
t415at419a
t401t401
a. Normal
b. Retry
c. Bus E r ror
0ns 100ns 200ns 300ns
QCLK
A[31:0]
CSPCI_
IMSEL
BURST_/TIP_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TA_b
TEA_b
TA_c
TEA_c
Appendix B: Timing
QSpan II User Manual 351
May 16, 2013
Figure 64: Delayed Burst Read — QSpan II as M68040 Slave
Wait states are inserted if the starting address is not aligned to 16-byte boundary.
t409a
t410et410e
t417
t418
t417
t418
t417
t418
t417
t418
t417
t415o
t419g
t415it419d
t415lt419f
t415jt419e
t415dt413g
t415ht413d
t415e
t419b
t415at419a
t401t401
0ns 250ns
QCLK
A[31:0]
CSPCI_
IMSEL
BURST_/TIP_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_
TEA_
Appendix B: Timing
QSpan II User Manual352 May 16, 20 13
Figure 65: Posted Burst Write — QSpan II as M68040 Slave
Wait states are be inserted if the starting address is not aligned to 16-byte boundary.
D1 D2 D3 D4
t409a
t436et410e
t415g
t413c
t415g
t413c
t415g
t413c
t415g
t413c
t415o
t419g
t415it419d
t415lt419f
t415jt419e
t415dt413g
t415ht413d
t415e
t419b
t415at419a
t401t401
0ns 250ns
QCLK
A[31:0]
CSPCI_
IMSEL
BURST_/TIP_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_
TEA_
Appendix B: Timing
QSpan II User Manual 353
May 16, 2013
Figure 66: Register Reads — QSpan II as M68040 Slave
t409b
t436gt410g
t409a
t436et410e
t409a
t436et410e
t416t418t417
t415o
t419g
t415it419d
t415lt419f
t415jt419e
t415dt413g
t415ft419c
t415at419a
t401t401
a. Normal
b. Retry
0ns 100ns 200ns 300ns 400ns
QCLK
A[31:0]
CSREG_
BURST_/TIP_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TA_b
TEA_b
Appendix B: Timing
QSpan II User Manual354 May 16, 20 13
Figure 67: Register Write — QSpan II as M68040 Slave
t409b
t436gt410g
t409a
t436et410e
t409a
t436et410e
t415at413c
t415o
t419g
t415it419d
t415lt419f
t415jt419e
t415dt413g
t415ft419c
t415at419a
t401t401
a. Norm al
b. Retry
0ns 250ns 500ns
QCLK
A[31:0]
CSREG_
BURST_/TIP_
SIZ[1:0]
TC[3:0]
R/W_
TS_
D[31:0]
TA_a
TEA_a
TA_b
TEA_b
Appendix B: Timing
QSpan II User Manual 355
May 16, 2013
B.4.5 Interrupts and Resets
Figure 68: Reset from PCI Interface — RST# related to RESETO_
Figur e 69 : So ft w are Reset
Figure 70: INT# Interrupt to QINT_ Interrupt
Figure 71: PERR# Interrupt
t002t001
0ns 100ns 200ns 300ns 400ns
RST#
RESETO_
t004t003
0ns 100ns 200ns 300ns 400ns
PCLK
RESETO_
t006t005
0ns 50ns 100ns 150ns 200ns
PCLK
QINT_
INT#
t006t005
0ns 25ns 50ns 75ns 100ns 125ns
PCLK
QINT_
PERR#
Appendix B: Timing
QSpan II User Manual356 May 16, 20 13
Figur e 72: SERR# Interrupt
Figure 73: QINT_ Interrupt to INT# Interrupt
t006t005
0ns 25ns 50ns 75ns 100ns 125ns
PCLK
QINT_
SERR#
t006t005
0ns 50ns 100ns 150ns 200ns
PCLK
QINT_
INT#
Appendix B: Timing
QSpan II User Manual 357
May 16, 2013
B.4.6 Reset Options
The parameters for the following figure are in Table 1 58 on page 313.
Figure 74: Rese t Opt ions
t025t024
t023t022
t021t020
t018t012
t017t011
t016t010
t015t009
t014t008
t013t007
t019ct019c
0ns 25ns 50ns
RESETI_ or RST#
SIZ[1]_
TMODE[0]
TMODE[1]
BDIP_
BM_EN
SDA
ENID
PCI_DIS
PCI_ARB_EN
Appendix B: Timing
QSpan II User Manual358 May 16, 20 13
QSpan II User Manual 359
May 16, 2013
Appendix C: Typical Applications
This appendix describes how to connect the QSpan II to the following Motorola-based
buses: MC68360 (QUICC), MPC860 (PowerQUICC), and M68040. Glue logic is not
required for any of these applications.
The following topics are discussed:
“MC68360 Interface” on page 359
“MPC860 Interface” on page 365
“M68040 Interface” on page 372
C.1 MC68360 Interface
This section describes how the QSpan II can be connected to the MC68360
communications controller.
C.1.1 Hardware Interface
C.1.1.1 Clocking
QSpan II must be clocked by the CLKO1 output from the MC68360 processor. All of
the AC timing waveforms for the QSpan II/MC68360 interface are based on CLKO1.
Appendix C: Typical Applications
QSpan II User Manual360 May 16, 20 13
Figure 75: MC68360 Interface
C.1.1.2 Resets
There are three reset situations depending upon the use of the QSpan II in your
application: PCI adapter card bridge, PCI Host bridge, or CompactPCI adapter card
supporting Hot Swap.
A[31:0]
D[31:0]
SIZ[1:0]
DSACK[1]_
R/W_
AS_
DS_
BR_
BG_
BGACK_
BERR_
HALT_
CSPCI_
CSREG_
IMSEL
DACK_
DONE_
DREQ_
IRQ[7:1]
FC[3:0] TC[3:0]
QINT_
IDMA
RESETO_RESETH_
QSpan IIMC68360
The QSpan II is an
autovector interrupter so
the MC68360 must be
configured to generate AVEC_
to terminate the IACK cycle
SDA and ENID control the
EEPROM port at reset.
TS_
SDA
BB_/BGACK_
BURST_/TIP_
HALT_/RETRY_
Oscillator
EXTAL
QCLK
CLKO1
BDIP_
Memory
Controller
BDIP must be pulled low for
360 master mode
DSACK1_/TA_
DSACK[0]_ DSACK0_
BERR_/TEA_
ENID
Reset Strategy for Host
Bridging Applications
Reset Strategy for PCI
Adapter Applications
RST#RESETH_
RESETI_
RESETO_
Connects to
PCI bus RST#
RESETI_
Appendix C: Typical Appl ications
QSpan II User Manual 361
May 16, 2013
For a PCI adapter card application, use the following reset configuration: connect the
QSpan II's reset output (RESETO_) to the hard reset input (RESETH_) on the
MC68360. This enables the QSpan II to reset the MC68360 when PCI RST# is asserted,
or when the software reset bit is asserted (SW_RST bit in the MISC_CTL register on
Table 127 on page 274). QSpan II’s reset input (RESETI_) is typically unused and
should be pulled high through a resistor. HS_HEALTHY_ should be left open as it has
an internal pull-down resistor.
For a PCI Host bridge application, use the following reset configuration: the QSpan II’s
PCI RST# (global reset for the QSpan II) input is connected to the hardware reset signal
(RESETH_) on the MC68360. QSpan II’s reset output (RESETO_) can be connected to
the PCI RST# inputs of the other PCI devices (the QSpan II’s RST# input is not
connected to the PCI bus RST# signal). Therefore, at power-up the MC68360’s
power-on-reset circuitry will assert RESETH_, which fully resets the QSpan II device.
QSpan II will assert RESETO_ to reset the agents on the PCI bus when RST# is active.
The reset example described in the previous paragraph also allows the MC68360
processor to reset all of the PCI agents under software control. The MC68360 can write
to the software reset bit in the QSpan II’s MISC_CTL regis ter, which will cause the
QSpan II to assert its RESETO_ signal. QSpan II's reset input (RESETI_) is typically
unused and should be pulled hi gh throug h a resistor (for more information about resets,
see Chapter 14: “Reset Options” on page 153). HS_HEALTHY_ should be left open as
it has an internal pull-down resistor.
For a CompactPCI adapter card that supports Hot Swap, use the following reset
configuration: the QSpan II’s HS_HEALTHY_ input should be connected to the Hot
Swap Controller’s HEALTHY_ output. Also, connect the QSpan II's reset output
(RESETO_) to the hard reset input (RESETH_) on the MC68360. This enables the
QSpan II to reset the MC68360 when PCI RST# is asserted, or when the software reset
bit is asserted (SW_RST bit in the MISC_CTL register on Table 127 on page 274).
QSpan II's reset input (RESETI_) is typically unused and should be pulled high through
a resistor.
C.1.1.3 Memory Controller
QSpan II requires that two chip selects be generated in order to access the registers
(CSREG_) and the PCI bus (CSPCI_). This is accomplished by using two of the chip
select outputs from the memory controller within the MC68360. There are two QBu s
slave images in the QSpan II which are used to access the PCI bus. The image that is
selected when the PCI chip select is asserted depends upon the state of the Image Select
signal (IMSEL). If IMSEL is low then QBus slave image 0 is selected; otherwise, QBus
slave image 1 is selected. IMSEL is typically generated directly from one of the
high-order address lines on the QBus (for example, dependent on the processors
memory map).
An alternative method is to use a spare I/O port pin on the MC68360 processor to
control the QSpan II’s IMSEL input pin. When the opposite QBus slave image must to
be accessed, the MC68360 will first perform a write to change the state of this I/O port
pin.
Appendix C: Typical Applications
QSpan II User Manual362 May 16, 20 13
C.1.1.4 QBus Direct Connects
All other QBus interface signals can be directly connected to the appropriate MC68360
signal. External pull-up resistors should be connected to all bus control signals —
excluding SIZ[1] and BDIP_ which are reset options and should be p ulled to the desired
state — to ensure that they are held in the inactive state. See Figure 75 to determine
which signals require external pull-ups.
C.1.1.5 Interrupts
QSpan II device can pass interrupts between the PCI bus and the QBus. For host
bridging applications, the QSpan II can accept INT# as an input and assert QINT_ as an
output. QSpan II's interrupt output (QINT_) should be connected to one of the seven
possible interrupt inputs (IRQ[7:1]) on the MC68360 processor. When the MC68360 is
acknowledging a QSpan II interrupt, it must be programmed to generate the cycle
termination. QSpan II is an autovector interrupter and does not have the ability to assert
AVEC_ during the interrupt acknowledge cycle.
For PCI adapter card applications, the QSpan II can accept interrupts from the QBus on
the QINT_ pin and pass them through the QSpan II to its PCI INT# output. See
Chapter 8: “The Interrupt Channel” on page 113 for more information about interrupts.
C.1.1.6 PCI Signals
QSpan II’s PCI signals can be directly connected to the appropriate PCI signal on the
motherboard or the PCI connector. Pull-up resistors may be required to be added to the
PCI bus control signals depending on the application. If you are designing a local PCI
bus on a motherboard then pull-up resistors are required (for more information, see the
PCI 2.2 Specification).
For host bridging applications, possible implementations for the QSpan II’s IDSEL
signal include the following:
connect it to a spare AD signal (AD[31:12])
connect it to ground through a resistor if the host is not required to respond to PCI
configuration cycles
The QSpan II supports both 5V and 3.3V I/O signaling environments.
C.1.1.7 EEPROM Interface
A serial EEPROM may be required for applications which must support a Plug and Play
environment (for more information about EEPROM reset options, see “Reset Options”
on page 363). QSpan II also allows that QBus processor to initialize the QSpan II to
support a Plug and Play environment (for more information, see “EEPROM
Configuration and Plug and Play Compatibility” on page 123).
VH (Highest I/O voltage) must be connected to the highest voltage level
the QSpan II I/Os will observe on either the QBus or the PCI bus.
Appendix C: Typical Appl ications
QSpan II User Manual 363
May 16, 2013
C.1.1.8 Reset Options
A number of reset options exist with the QSpan II device. The following signals are
sampled on the rising edge of both RST# and RESETI_, and the falling edge of
HS_HEALTHY_ to determine the QSpan II’s mode of operation:
The BDIP_ signal must be pulled low at reset to enable the QSpan II to perform as
an MC68360 master. QSpan II responds to MC68360-style slave cycles
independent of the state of the SIZ[1] signal at reset (see Chapter 14: “Reset
Options” on page 153).
The SDA and ENID signals should be pulled high if the EEPROM is used. The
SDA signal should be pulled low if the serial EEPROM is not used in this design.
The ENID signal can be left open if the serial EEPROM is not used as there is an
internal weak pull-down resistor.
The TMODE[1:0] signals can be left open as the re a r e internal pull-down res is t o rs
on these pins within the QSpan II. If an in-circuit tester is used during the board
manufacturing process then these two signals should be brought out as test points.
This allows the in-circuit tester to place the QSpan II in a tri-state/NAND TREE
test mode.
If the BM_EN/FIFO_RDY_ signal is sampled high while RST# is asserted, the
QSpan II sets the Bus Master (BM) bit in the PCI_CS register (see Table 70 on
page 201). This enables the QSpan II as a PCI bus master. This pin can be left as a
no-connect as there is an internal weak pull-down resistor.
If the PCI_ARB_EN signal is sampled high on the negation of a reset event then
the PCI bus arbiter within the QSpan II is enabled. There is an internal pull-down
resistor on this pin to maintain backward compatibility.
If the PCI_DIS signal is sampled high on the negation of a reset event then the
QSpan II’s PCI interface is disabled. QSpan II will retry any attempted PCI target
accesses until the PCI_DIS status bit in the MISC_CTL2 register is cle ared (see
Table 130 on page 278). There is an internal pull-down resistor on this pin to
maintain backward compatibility.
Reset options are described in Chapter 14: “Reset Options” on page 153.
C.1.1.9 Unused Inputs Requiring Pull-Ups
The TS_ and BURST_/TIP_ signals are unused inputs when the QSpan II is interfaced
with an MC68360, and therefore, must be pulled high.
C.1.1.10 No Connects
The BM_EN/FIFO_RDY_ signal can be left as a no-connect as there is an internal weak
pull-down resistor. In this case, in order for the QSpan II to become a PCI bus master a
write to the PCI_CS register is required.
C.1.1.11 JTAG Signals
QSpan II supports JTAG. QSpan II’s JTAG signals should be connected to the JTAG
controller or to the JTAG signals of another device if devices are to be chained toge ther.
If JTAG will not be supported then the JTAG signals can be left open as the inputs have
internal pull-up resistors.
Appendix C: Typical Applications
QSpan II User Manual364 May 16, 20 13
C.1.1.12 Address Multiplexing for DRAM
If DRAM is used on the QBus, external address multiplexing is required. This is
described in Motorola’s MC68360 User Manual.
C.1.2 Software Issues
When using the MC68360 with the QSpan II there are register bits which must be
altered from the MC68360’s default reset state. The register bits should be set as
follows:
Set the Bus Synchronous Timing Mode (BSTM) bit to 1 in the MCR register
because the QSpan II is a synchronous bus master.
Set the Arbitration Synchronous Timing Mode (ASTM) bit to 0 in the MCR
register because the QSpan II is not able to meet the MC68360’s set-up
requirements.
C.1.3 MC68360 Slave Mode Interface
If the MC68360 operates in Slave mode — its processor core is disabled — an external
QBus arbiter must be used to support arbitration between the MC68360 and the
QSpan II. QSpan II’s arbitration interface does not support the use of the MC68360’s
internal bus arbiter when the processing core is disabled. If the processing core is
disabled, the external arbiter receives bus requests (BR) from both the MC68360 and
QSpan II, and then issues bus grants (BG) back to the appropriate device.
If the MC68360 operates in Slave mode, set the MC68360’s SYNC bit to 0 in the GMR
register.
Setting the S_BG and S_BB bits to 1 was a requirement for the QSpan
(CA91C860B, CA91L860B) devices. This setting is not required for the
QSpan II. However, setting these bits to a 1 will save one clock cycle. If
both these bits are set to 1, the QSpan II will synchronously sample the
MC68360’s arbitration outputs, and the MC68360 will asynchronously
sample the QSpan II’s arbitration outputs.
Appendix C: Typical Appl ications
QSpan II User Manual 365
May 16, 2013
C.2 MPC860 Interface
This section describes how the QSpan II can be connected to the MPC860
communications controller (and other MPC8xx devices).
Figur e 76 : MPC 8 60 Interface
A[0:31]
D[0:31]
TSIZ[0:1]
R/W_
BDIP_
BURST_
BR_
BG_
TEA_
RETRY_
SDACK_
DREQ_
IRQ[7:1]
AT[0:3] TC[3:0]
IDMA
QSpan II
MPC860
DS_ can be no-connect
DSACK0
_
SDA
BDIP_ must be pulled up for 860
master mode
TA_
QINT_
TS_
BB_
DACK_
HALT_/RETRY_
DONE
_
BURST_/TIP_
Oscillator
CLKOUT
A[31:0]
D[31:0]
SIZ[1:0]
IMSEL
CSPCI_
CSREG_
QCLK
EXTCLK
TMODE[1:0]
Memory
Controller
BB_/BGACK_
BERR_/TEA_
DSACK1_/TA_
AS
_
RESETO_RESETH_
RESETI_
Reset Strategy for Host
Bridging Applications
Reset Strategy for PCI
Adapter Applications
ENID
SDA and ENID control the EEPROM
port at reset.
RST#RESETH_
RESETI_
RESETO_
Connects to
PCI bus RST#
Appendix C: Typical Applications
QSpan II User Manual366 May 16, 20 13
C.2.1 Hardware Interface
C.2.1.1 Clocking
The QSpan II’s QCLK input must be derived from the MPC860’s CLKOUT signal. All
of the AC timing waveforms for the QSpan II are based on this clock output. It is
recommended, however, to buffer the CLKOUT signal to the QSpan II with a low skew
PLL-based clock buffer because of the low drive strength of the CLKOUT signal.
Clocking the QSpans QCLK Input with a PLL Clock Buffer Chip
QSpan II does not tolerate external bus cycles occurring on the QBus when it does not
have a stable clock input.
In the MPC860/QSpan II application shown in Figure 77, the QSpan II may not respond
to a register or PCI access if MPC860 bus cycles are occurring when the QSpan II does
not have a stable clock.
In this example, the XTAL clock input to the MPC860 is only 4 MHz. The MPC860’s
PLPRCR register can be written to increase the clock’s frequency. When the frequency
is increased the MPC860 will stop generating a CLKOUT signal for a period of time
while the PLL is locking to this higher frequency. The MPC860 will then continue
executing instructions once the CLKOUT signal is stable at this higher frequency.
However, the QSpan II will not yet have a stable QCLK input due to the PLL locking
requirement of the external PLL Clock buffer chip — the PLL locking time is
dependent on the selected clock buffer chip but is typically around 1 ms. During this
period while the external PLL is locking, the MPC860 must not perform any cycles on
the bus or the QSpan II will not respond to the next register or PCI access.
Figur e 77 : MPC 8 60 /QSpa n II Clocking Scheme Example
If an external PLL clock buffer generates the QSpan II’s QCLK input,
care must be taken to ensure the QSpan II’s set-up and hold times are not
violated while the PLL clock buffer is locking.
MPC860 PLL CLK
Buffer QSpan II
4 MHz
XTAL
CLKOUT QCLK
Appendix C: Typical Appl ications
QSpan II User Manual 367
May 16, 2013
This issue can be eliminated by having the MPC860 execute a delay loop from its
instruction cache during this time period. This will prevent the MPC860 from asserting
the cycle on the external bus (that is, TS_ will not be asserted). An example of how this
code could be implemented is in Figure 78.
C.2.1.2 Resets
There are three reset scenarios depending on the use of the QSpan II in your application:
PCI adapter card bridge, PCI Host bridge, or CompactPCI adapter card supporting Hot
Swap.
For a PCI adapter card application use the following reset configuration: connect the
QSpan II's reset output (RESETO_) to the hard reset input (RESETH_) on the MPC860.
This enables the QSpan II to reset the MPC860 when PCI RST# is asserted or when the
software reset bit is asserted (SW_RST bit in the MISC_CTL register on Table 127 on
page 274). QSpan II's reset input (RESETI_) is typically unused and should be pulled
high through a resistor. HS_HEALTHY_ should be left open as it has an internal
pull-down resistor.
Figure 78: Example Code for Executing an MPC860 Delay Loop
# R4 Contains IMMR value
bl icache_unlock_all # ICache Unlock All
bl icache_invalidate_all # ICache Invalidate All
bl icache_enable # ICache Enable
# prefetch wait_delay subroutine into instruction cache
li r1, 0x1 # set delay counter for wait_delay subroutine
bl wait_delay
li r5,0xA0 # multiply factor from 4MHZ
b aligned
.align 4 # align address to 16-bytes boundary
aligned:
sth r5,PLPRCR(r4) # set the PLL register
isync
# delay allows for QSpan II to receive a stable QCLK before external bus
cycles begin
# the actual delay value required is dependent on the PLL clock buffer
device’s locking time
li r1, 0x7FFF # set delay counter for wait_delay subroutine
bl wait_delay
# Simple delay routine, (R1 delay counter input parameter)
wait_delay:
#
# execute required delay with R1 parameter
#
blr
Appendix C: Typical Applications
QSpan II User Manual368 May 16, 20 13
For a PCI Host bridge application use the following reset configuration: the QSpan II’s
PCI RST# (global reset for the QSpan II) input is connected to the hardware reset
(RESETH_) on the MPC860. QSpan II’s reset output (RESETO_) can be connected to
the PCI RST# inputs of the other PCI devices (the QSpan II’s RST# input is not
connected to the PCI bus RST# signal). Therefore, at power-up the MPC860’s
power-on-reset circuitry will assert RESETH_ which fully resets the QSpan II.
QSpan II will, in turn, assert RESETO_ to reset the agents on the PCI bus when RST# is
active.
This reset example also allows the MPC860 processor to reset all of the PCI agents
under software control. The MPC860 can write to the software reset bit in the QSpan
II’s MISC_CTL register, which will cause the QSpan II to assert its RESETO_ signal.
QSpan II's reset input (RESETI_) is typically unused and should be pulled high through
a resistor. Resets are described in Chapter 14: “Reset Options” on page 153.
HS_HEALTHY_ should be left open as it has an internal pull-down resistor.
For a CompactPCI adapter card that supports Hot Swap, use the following reset
configuration: the QSpan II’s HS_HEALTHY_ input should be connected to the Hot
Swap Controllers HEALTHY_ output. Also, connect the QSpan II's reset output
(RESETO_) to the hard reset input (RESETH_) on the MPC860. This enables the
QSpan II to reset the MPC860 when PCI RST# is asserted, or whe n the softwa re reset
bit is asserted (SW_RST bit in the MISC_CTL register on Table 127 on page 274).
QSpan II's reset input (RESETI_) is typically unused and should be pulled high through
a resistor.
C.2.1.3 Memory Controller
QSpan II requires that two chip selects be generated in order to access the registers
(CSREG_) and the PCI bus (CSPCI_). This can be accomplished by using two of the
chip select outputs from the memory controller within the MPC860. There are two
QBus slave images within the QSpan II which are used to access the PCI bus. The
image that is selected when the PCI chip select is asserted is dependent on the state of
the Image Select signal (IMSEL). If IMSEL is low then QBus slave image 0 is selected;
otherwise, QBus slave image 1 is selected. IMSEL is typically generated directly from
one of the high order address lines on the QBus (for example, dependent on the
processors memory map).
An alternative method is to use a spare I/O port pin on the MPC860 processor to control
the QSpan II’s IMSEL input pin. If the opposite QBus slave image is desired to be
accessed, the MPC860 first performs a write to change the state of this I/O port pin.
C.2.1.4 QBus Direct Connects
The bus interface signals can be directly connected together. External pull-up resistors
should be connected to all bus control signals — including SIZ[1] and BDIP_ which are
reset options and should be pulled high to supp ort MPC860 mode — to ensure that they
are held in the inactive state (see Figure 76 to determine which signals require external
pull-ups).
Appendix C: Typical Appl ications
QSpan II User Manual 369
May 16, 2013
C.2.1.5 Interrupts
QSpan II can pass interrupts between the PCI bus and the QBus. For host bridging
applications, the QSpan II can accept INT# as an input and assert QINT_ as an output.
QSpan II’s interrupt output QINT_) should be connected to one of the seven possible
interrupt inputs (IRQ[7:1]) on the MPC860 processor.
For PCI adapter card applications, the QSpan II can accept interrupts from the QBus on
the QINT_ pin and pass them through the QSpan II to its PCI INT# output. Interrupts
are described in Chapter 8: “The Interrupt Channel” on page 113.
C.2.1.6 PCI Signals
QSpan II’s PCI signals can be directly connected to the appropriate PCI signal on the
motherboard or the PCI connector. Pull-up resistors may be required to be added to the
PCI bus control signals depending on the application. If you are designing a local PCI
bus on a motherboard then pull-up resistors will be required (for more information, see
the PCI Specification 2.2).
For host bridging applications, possible implementations for the QSpan II’s IDSEL
signal are as follows:
connect it to a spare AD signal (AD[31:12])
connect it to ground through a resistor if the host is not required to respond to PCI
configuration cycles
The QSpan II supports both 5V and 3.3V I/O signaling environments.
C.2.1.7 EEPROM Interface
A serial EEPROM may be required for applications which must support a Plug and Play
environment (for more information about EEPROM reset options see “Reset Options”
on page 363). QSpan II also allows that QBus processor to initialize the QSpan II to
support a Plug and Play environment (for more information, see “EEPROM
Configuration and Plug and Play Compatibility” on page 123).
C.2.1.8 Reset Options
A number of reset options exist with the QSpan II device. The following signals are
sampled on the rising edge of both RST# and RESETI_ and the falling edge of
HS_HEALTHY_ to determine the QSpan II’s mode of operation:
The BDIP_ and SIZ[1] signals must be pulled high at reset to enable the QSpan II
to perform as an MPC860 master an d slave (see Chapter 14: “Reset Options”
on page 153).
The SDA and ENID signals should be pulled high if the EEPROM is used. The
SDA signal should be pulled low if the serial EEPROM is not used in this design.
The ENID signal can be left open if the serial EEPROM is not used as there is an
internal weak pull-down resistor.
VH (Highest I/O voltage) must be connected to the highest voltage level
the QSpan II I/Os will observe on either the QBus or the PCI bus.
Appendix C: Typical Applications
QSpan II User Manual370 May 16, 20 13
The TMODE[1:0] signals can be left open as the re a r e internal pull-down res is t o rs
on these pins within the QSpan II. If an in-circuit tester is used during the board
manufacturing process then these two signals should be brought out as test points.
This allows the in-circuit tester to place the QSpan II in a tri-state/NAND TREE
test mode.
If the BM_EN/FIFO_RDY_ signal is sampled high while RST# is asserted, the
QSpan II sets the Bus Master (BM) bit in the PCI_CS register (see Table 70 on
page 201). This enables the QSpan II as a PCI bus master. This pin can be left as a
no-connect as there is an internal weak pull-down resistor.
If the PCI_ARB_EN signal is sampled high on the negation of a reset event then
the PCI bus arbiter within the QSpan II is enabled. There is an internal pull-down
resistor on this pin to maintain backward compatibility.
If the PCI_DIS signal is sampled high on the negation of a reset event then the
QSpan II’s PCI interface is disabled. QSpan II will retry any attempted PCI target
accesses until the PCI_DIS status bit in the MISC_CTL2 register is cle ared (see
Table 130 on page 278). There is an internal pull-down resistor to maintain
backward compatibility.
Reset options are described in Chapter 14: “Reset Options” on page 153.
C.2.1.9 Unused Inputs Requiring Pull-Ups
The AS_, DSACK0_ and DONE_ signals are unused inputs when the QSpan II is
interfaced with an MPC860, and therefore, must be pulled high.
C.2.1.10 No Connects
The DS_ output from the QSpan II should be left as a no connect when the QSpan II is
interfaced with an MPC860.
The BM_EN/FIFO_RDY_ can be left as a no-connect as there is an internal weak
pull-down resistor. In this case, in order for the QSpan II to become a PCI bus master a
write to the PCI_CS register is required.
C.2.1.11 JTAG Signals
QSpan II supports JTAG. QSpan II’s JTAG signals should be connected to the JTAG
controller or to the JTAG signals of another device if devices are to be chained toge ther.
If JTAG will not be supported then the JTAG signals can be left open as the inputs have
internal pull-up resistors.
C.2.1.12 Bused Signals
This manual adopts the convention that the most significant bit (address, data, size and
transaction codes) is always the largest number. When interfacing the MPC860 to the
QSpan II, designers must ensure that they connect the signals accordingly (for example,
pin A[31] on the QSpan II connects to pin A[0] on the MPC860).
C.2.1.13 Address Multiplexing for DRAM
Whenever DRAM is used on the QBus, external address multiplexing is required. This
is described in the MPC860 UM/AD (REV1).
Appendix C: Typical Appl ications
QSpan II User Manual 371
May 16, 2013
C.2.1.14 Software Issues
When using the MPC860 with the QSpan II there are a few register bits that must be
changed from the MPC860’s default reset state. These register bits include the
following:
The MLRC bits in the MPC860’s SIUMCR register must be changed to 10 state.
This configures the KR/RETRY/IRQ4/SPKROUT pin to function as a RETRY
input.
The SEME bit in the MPC860’s SIUMCR register must be set to a 1 because the
QSpan II is a synchronous external master.
The SETA bit in the MPC860’s Option register must be set to a 1 for the two
QSpan II chip selects (CSREG_ and CSPCI_). QSpan II will always provide the
cycle termination to the MPC860.
The BIH bit in the MPC860’s Option register must be set to 1 for the QSpan II’s
register chip select (CSREG_). QSpan II’s PCI chip select (CSPCI_) pin supports
burst accesses when using the MPC860’s GPCM. Therefore, the BIH bit can be set
to either state. The MPC860 Users Manual states that the GPCM machine does not
support burst accesses, however, with the QSpan II’s architecture it will function
correctly for the CSPCI_ chip select.
Appendix C: Typical Applications
QSpan II User Manual372 May 16, 20 13
C.3 M68040 Interface
This section describes how the QSpan II can be connected to the M68040.
Figur e 79 : M6 8040 Interface
A[31:0]
D[31:0]
SIZ[1:0]
TS_
R/W_
BURST_/TIP_
BR_
BG_
BB_
TEA_
IPL[2:0] QINT_
AS_, DACK_, DONE_, DSACK0_, BDIP_, RETRY_
QSpan IIM68040
The QSpan is an
autovector interrupter
soexternal logic will be
required to assert AVEC
to the M68040
SIZ[1] must be pulled
down. SIZ[0] pulled up.
DREQ_ and DS_ can be no-connects
TT[1:0], TM[2:0] TC[3:0] If not used TC should be
pulled-up.
TA_
Separate pull-ups
M68040 master mode if
SIZ[1] = 0 and BDIP_ = 1
at reset
BR_
BG_
BB_
TIP_
CSPCI
_
CSREG
_
IMSEL
External Address
Decode Logic
BCLK QCLK
BERR
_
/TEA
_
DSACK1
_
/TA
_
Oscillator
Arbiter
Interrupt
Prioritizing Logic
SDA and ENID control the
EEPROM port at reset.
SDA
ENID
RSTI
_
RESETI_
RESETO Reset Stratedgy for PCI
Adapter Card Applications
RSTO
_
RESETI_
RESETO
_
Reset Circuitry Reset Stratedgy for Host
Bridging Application
RSTI
_
RST#
PCI Bus RST# Signal
Generates the PCI bus
RST# signal
Appendix C: Typical Appl ications
QSpan II User Manual 373
May 16, 2013
C.3.1 Hardware Interface
C.3.1.1 Clocking
QSpan II's QCLK input and the M68040's BCLK input should be clocked from the
same clock source. The AC timing waveforms for the QSpan II are based on this
assumption.
C.3.1.2 Resets
There are three reset scenarios depending on the use of the QSpan II in your application:
PCI adapter card bridge, PCI Host bridge, or CompactPCI adapter card supporting Hot
Swap.
For a PCI Adapter card application, use the following reset configuration: connect the
QSpan II's reset output (RESETO_) to the external reset lo gic to the reset input (RSTI_)
on the M68040. This enables the QSpan II to reset the M68040 processor when PCI
RST# is asserted, or when the software reset bit is asserted (SW_RST bit in the
MISC_CTL register on Table 127 on page 274). QSpan II's reset input (RESETI_) is
normally unused and should be pulled high through a resistor.
For a PCI Host bridge application, use the following reset configuration: the QSpan II’s
PCI RST# (global reset for the QSpan II) input is connected to the reset output (RSTO_)
on the M68040. QSpan II’s reset output (RESETO_) can be connected to the PCI RST#
inputs of the other PCI devices (the QSpan II’s RST# input is not connected to the PCI
bus RST# signal). Therefore, at power-up the M68040’s power-on-reset circuitry will
assert RSTO_ which fully resets the QSpan II device. QSpan II will assert RESETO_ to
reset the agents on the PCI bus when RST# is active.
This reset example also allows the M68040 processor to reset all of the PCI agents
under software control. The M68040 can write to the software reset bit in the QSpan II’ s
MISC_CTL register which will cause the QSpan II to assert its RESETO_ signal.
QSpan II's reset input (RESETI_) is normally unused and should b e pulled high through
a resistor (for more information about resets, see Chapter 14: “Reset Options”
on page 153).
For a CompactPCI adapter card application that supports Hot Swap, the QSpan II’s
HS_HEALTHY_ signal should be connected to the Hot Swap contr oller’s HEALTHY_
signal.
QSpan II is compatible with all M68040 variants in lar ge buffer mode up
to 40 MHz. QSpan II is compatible with all M68040 variants in small
buffer mode up to 33 MHz.
Appendix C: Typical Applications
QSpan II User Manual374 May 16, 20 13
C.3.1.3 Address Decoder
QSpan II requires two chip selects and an image select signal (IMSEL) to be generated
in order to access the registers (CSREG_) and the PCI bus (CSPCI_). There is no
internal memory controller within the M68040 and therefore an external address
decoder must be implemented. The IMSEL signal determines which QBus slave image
is accessed when CSPCI_ is asserted to the QSpan II. If IMSEL is low then QBus slave
image 0 is selected; otherwise QBus slave image 1 is selected. IMSEL is typically
dependent on the processor’s memory map and is generated directly from one of the
high order address lines.
An alternative method is to use a registered output which resides on the QBus. When
the opposite slave image must be accessed, the M68040 would first perform a write to
change the state of this registered output.
C.3.1.4 QBus Direct Connects
All other bus interface signals can be connected directly together. External pull-up
resistors should be connected to all bus control signals — exclud ing SIZ[1 ] and BDIP_
which are power-up options and shou ld be pulled to the desired state — to ensure that
they are held in the inactive state (see Figure 79 to determine which signals require
external pull-ups).
Depending on the version and speed of the M6 8040 device selected for a design, an
extra wait state may need to be inserted on the transfer start signal (TS_). This may be
required because the external address decoding circuitry may not be able to generate the
chip selects to the QSpan II to meet the input setup requirements.
An alternate solution is to use large output buffer mode in the M68040 to eliminate the
need for this wait state. The M68040’s output propagation delays are much quicker in
this mode and therefore there is more timing margin available for interfacing the
QSpan II. However, if large output buffer mode is chosen, it must be used in an
unterminated method as the QSpan II's output drivers do not have the ability to drive a
50 ohm transmission line terminated at 2.5V.
QSpan II has four transaction code TC[3:0] signals which can be connected to any four
of the five following sign als on the M68040: TT[1:0] and TM[2:0].
C.3.1.5 Interrupts
QSpan II device can pass interrupts between the PCI bus and the QBus. For host
bridging applications, the QSpan II can accept INT# as an input and assert QINT_ as an
output. QSpan II's interrupt output (QINT_) should be connected to the interrupt
prioritizing logic which is connected to the IPL[2:0] lines on the M68040 processor.
When the M68040 is acknowledging a QSpan II interrupt there must be external logic
to terminate the cycle. External logic is required because the QSpan II is an autovector
interrupter which does not have the ability to assert AVEC_ or TA_ during the interrupt
acknowledge cycle.
For PCI adapter card applications, the QSpan II can accept interrupts from the QBus on
the QINT_ pin and pass them through the QSpan II to its PCI INT# output (see
Chapter 8: “The Interrupt Channel” on page 113 for more information about interrupts).
Appendix C: Typical Appl ications
QSpan II User Manual 375
May 16, 2013
C.3.1.6 PCI Signals
QSpan II’s PCI signals can be connected directly to the appropriate PCI signal on the
motherboard or the PCI connector. Pull-up resistors may be required to be added to the
PCI bus control signals depending on the application. If you are designing a local PCI
bus on a motherboard then pull-up resistors will be required (for more information, see
the PCI 2.2 Specification).
For host bridging applications, possible implementations for the QSpan II’s IDSEL
signal are as follows:
connect it to a spare AD signal (AD[31:12])
connect it to ground through a resistor if the host is not required to respond to PCI
configuration cycles
The QSpan II supports both 5V and 3.3V I/O signaling environments.
C.3.1.7 EEPROM Interface
A serial EEPROM may be required for applications which must support a Plug and Play
environment (for more information about EEPROM reset options, see “Reset Options”
on page 363). QSpan II also allows that QBus processor to initialize the QSpan II to
support a Plug and Play environment (for more information, see “EEPROM
Configuration and Plug and Play Compatibility” on page 123).
C.3.1.8 Reset Options
QSpan II supports a number of reset options. The following signals are sampled on the
rising edge of both RST# and RESETI_ to determine the QSpan II’s mode of operation.
The BDIP_ signal must be pulled high and SIZ[1] pulled low at reset to enable the
QSpan II to perform as an M68040 mast er. The SIZ[1] signal must be pulled low at
reset in order for the QSpan II to decode an M68040 cycle
The SDA and ENID signals should be pulled high if the EEPROM is used. The
SDA signal should be pulled low if the serial EEPROM is not used in this design.
The ENID signal can be left open if the serial EEPROM is not used as there is an
internal weak pull-down resistor.
The TMODE[1:0] signals can be left open as the re a r e internal pull-down res is t o rs
on these pins within the QSpan II. If an in-circuit tester will be used during the
board manufacturing process then these two signals should be brought out as test
points. This would allow the in-circuit tester to place the QSpan II in a
tri-state/NAND TREE test mode.
If the BM_EN/FIFO_RDY_ signal is sampled high while RST# is asserted, the
QSpan II sets the Bus Master (BM) bit in the PCI_CS register (see Table 70 on
page 201). This enables the QSpan II as a PCI bus master. This pin can be left as a
no-connect as there is an internal weak pull-down resistor.
VH (Highest I/O voltage) must be connected to the highest voltage level
the QSpan II I/Os will observe on either the QBus or the PCI bus.
Appendix C: Typical Applications
QSpan II User Manual376 May 16, 20 13
If the PCI_ARB_EN signal is sampled high on the negation of a reset event then
the PCI bus arbiter within the QSpan II is enabled. There is an internal pull-down
resistor on this pin to maintain backward compatibility.
If the PCI_DIS signal is sampled high on the negation of a reset event then the
QSpan II’s PCI interface is disabled. QSpan II will retry any attempted PCI target
accesses until the PCI_DIS status bit in the MISC_CTL2 register is cle ared (see
Table 130 on page 278). There is an internal pull-down resistor to maintain
backward compatibility.
Reset options are described in Chapter 14: “Reset Options” on page 153.
C.3.1.9 Unused Inputs Requiring Pull-Ups
The AS_, DSACK0_, HALT_/TRETRY_, DONE_ and DACK_ signals are unused
inputs when the QSpan II is interfaced with a M68040 and therefore must be pulled
high.
C.3.1.10 No Connects
The DS_ and DREQ_ outputs from the QSpan II should be left as no connects when the
QSpan II is interfaced with a M68040.
The BM_EN/FIFO_RDY_ can be left as a no-connect as there is an internal weak
pull-down resistor. In this case, in order for the QSpan II to become a PCI bus master a
write to the PCI_CS register is required.
C.3.1.11 JTAG Signals
QSpan II supports JTAG. QSpan II’s JTAG signals should be connected to the JTAG
controller or to the JTAG signals of another device if devices are to be chained toge ther.
If JTAG will not be supported then the JTAG signals can be left open as the inputs have
internal pull-up resistors.
QSpan II User Manual 377
May 16, 2013
Appendix D: Software Initialization
This appendix explains how to initialize the QSpan II. It describes which registers must
be configured before you can initiate a transaction through the QSpan II’s channels.
This appendix also recommends how to set QSpan II’s register bits in order to achieve
maximum performance.
This appendix discusses the following topics:
“Miscellaneous Control Register Configuration” on page 378
“QBus Slave Channel Initialization” on page 380
“Register Access from the PCI Bus” on page 381
“PCI Target Channel Initialization” on page 381
“Error Logging of Posted Transactions” on page 383
“IDMA/DMA Channel Initialization” on page 384
“Interrupt Initialization” on page 384
“Generation of PCI Configuration and IACK Cycles” on page 385
“EEPROM and VPD Initialization” on page 386
“I2O Messaging Unit Initialization” on page 386
“PCI Expansion ROM Implementation” on page 387
Appendix D: Software Initialization
QSpan II User Manual378 May 16, 20 13
D.1 Miscellaneous Control Register Configuration
QSpan II has two general purpose control registers, MISC_CTL and MISC_CTL2,
which must be configured for the appropriate application (for example, MPC860
(PowerQUICC), MC68360 (QUICC), and M68040 processors). For more information
about the control registers, see Tables 161 and 162.
QSpan II’s MISC_CTL2 register bits which affect the device’s performance or
initialization are shown in Table 162.
Table 161: Summary of the QSpan II’s Miscellaneous Control Register
Register Field Description
MISC_CTL MSTSLV[1:0] This field determines the types of cycles the QSpan II Slave Module
accepts, and the type of cycles the Master Module generates. Rea d this
field to verify that the QSpan II has powered up in the correct mode of
operation.
QB_BOC This bit determines whether the QSpan II generates Little-endian or
Big-endian QBus cycles (see also INVEND bit in PCI target and DMA
control registers).
S_BG If using the MPC860’s arbiter, use default settings.
If using the MC68360’s arbiter, then these bits may be altered from
their default settings (for example, set to 1). This will improve the
performance by saving a clock cycle during arbitration.
S_BB
SW_RST This bit controls the assertion of RESETO_. Depending on the
hardware design, this output can be used to reset the QBus processor.
MA_BE_D This bit controls the QSpan II’s response to the QBus processor when a
Master-Abort occurs on the PCI bus. Set this bit to 1 before the
QSpan II performs any PCI Configuration cycles.
PRCNT This field controls the amount of data that is prefetched when a PCI
burst read occurs to the QSpan II’s PCI Target Channel.
If the PCI Initiators perform burst read cycles then prefetching should
be enabled to improve the system’ s performance. For more information,
see the PCI Target Channel’s control registers in Appendix A:
“Registers” on page 193.
Appendix D: Software Initialization
QSpan II User Manual 379
May 16, 2013
Table 162: Summary of the QSpan II’s Miscellaneous Control Register 2
Register Field Description
MISC_CTL2 PCI_DIS This bit must be cleared before any PCI Target accesses will complete
successfully.
PTP_IB This field allows the PCI Target Channel Prefetch Count to be Image
Based. Enable this feature if the PCI Initiators have dif ferent PCI
bursting requirements.
KEEP_BB This bit allows the QSpan II to hold onto the QBus for back-to-back
cycles. Setting this bit will improve the performance through the QSpan
II, however, it will sometimes increase the latency for the QBus
processor to obtain the QBus.
Note: Do not set this bit when the QSpan II DMA channel is used with
the PowerQUICC memory controller (UPM).
MAX_RTRY[1:0] This field can be set to a non-zero value to allow the QBus processor to
detect a cycle which has not completed successfully on the PCI bus.
PTC_PD This bit can be set to 1 to allow the QSpan II to signal a PCI disconnect
if TRDY# has been negated for more than eight PCI clocks.
TA_BE_EN Set this bit to 1 so that the QSpan II will signal a bus error to the QBus
processor if a PCI Target-Abort occurs.
BURST_4 Set this bit to 1 to enable the QSpan II to perform burst cycles in
MPC860 applications. For MC68360 and M68040 applications, this bit
can be left cleared. Used in conjunction with the BRSTWREN bit in the
PBTIx_CTL register (see Table 8 9 on page 222 and Table 92 on
page 226).
PR_SING Set this bit to 1 if the memory on the QBus does not support burst
accesses. This bit is only applicable when the QSpan II is configured as
an MPC860 QBus master.
PR_CNT2[5:0] This field controls the amount of data that is prefetched when a PCI
burst read occurs through PCI Target Channel 1 of the QSpan II. If the
PCI Initiators perform burst read cycles then prefetching should be
enabled to improve the system’s performance. For more information
about the PCI Target Channel control registers, see Appendix A:
“Registers” on page 193.
REG_AC Set this bit to 1 to improve the system’s perfo rmance if QSpan II
register accesses are occurring from both the QBus and PCI bus.
NOTO Set this bit to 1 to improve the system’s performance by disabling the
PCI transaction ordering rules between the QBus Slave and PCI Target
Channels (see “Transaction Ordering Disable Option” on page 76).
QSC_PW Set this bit to 1 to improve the posted write performance in the QBus
Slave Channel.
Appendix D: Software Initialization
QSpan II User Manual380 May 16, 20 13
The PCI Arbiter Control Register (PCI_ARB) should be initialized if the QSpan II is
the PCI Host and its arbiter was enabled at power-up (see the following table).
D.2 QBus Slave Channel Initialization
To support two QBus (processor) slave images you must program QBus slave image 0
and 1 registers. Once these registers are programmed, the QBus processor can read and
write data from the PCI bus.
Table 163: PCI Arbiter Control Register Summary
Register Field Description
PARB_CTL Mx_PRI This bit selects low or high priority for each PCI master.
QS_PRI This bit selects the QSpan II’s priority.
PCI_ARB_EN Read this status bit to verify whether the QSpan II has powered up with
the correct setting for enabling the arbiter.
PARK This bit allows you to park the PCI bus at different masters.
BM_PARK[2:0] 3-bit encoded field to select the master at which to park the bus (see
“Bus Parking” on page 142).
Table 164: QBus Slave Channel Programming Summary
Register Field Description
QBSI0_CTL
and/or
QBSI1_CTL
PWEN Set this bit to 1 to allow write transactions to be posted; this will
improve system throughput.
PAS Sets the PCI bus address space to either Memory or I/O space.
Typically, only Memory Space accesses are implemented
PREN Enables the QSpan II to perform a burst read on the PCI bus. Set this bit
if the QBus processor is often reading from consecutive PCI addresses.
QBSI0_AT
and/or QBSI1_AT EN This bit enables address translation when set to 1.
BS[3:0] Block Size of slave image: af fects number of address lines translated, if
address translation is enabled
TA[31:16] This field allows for independent memory maps to be created for the
PCI bus and QBus (EN bit must be set to 1).
PCI_CS BM This bit must be set before the QSpan II will initiate any transaction on
the PCI bus.
Appendix D: Software Initialization
QSpan II User Manual 381
May 16, 2013
D.3 Register Access from the PCI Bus
QSpan II’s PCI Configuration registers are accessible from the PCI Bus in PCI
Configuration or Memory Space. QSpan II device specific registers are only accessible
in Memory Space. QSpan II’s PCI Configuration Registers are accessible without any
software initialization requirements. To access the QSpan II device specific registers in
PCI Memory Space, configure the bits listed in the following table.
D.4 PCI Target Channel Initialization
There are two possible memory ranges on the PCI bus which can be used to gain access
to QBus memory. These two ranges and the associated registers wh ich need to be
programmed to access them are referred to as “target images.” Each PCI target image
can have independent features as described in the following table. To support two PCI
target images, you must program both PCI Target Image 0 and Image 1 registers.
Table 165: Register Access
Register Field Description
PCI_CS MS Set this bit for the QSpan II to be able to respond to PCI Memory space
cycles. (This is a global bit, the PAS bit of each specific image also
needs to be set.)
PCI_BSM BA Specifies the base address of the PCI memory image for access
registers (size of image is 4K)
Table 166: PCI Target Image Programming Summary
Register Field Description
PCI_CS MS Set this bit to allow the QSpan II to respond to PCI Memory space
cycles. This is a global bit, the PAS bit of each specific image also
needs to be set.
IOS Set this bit to allow the QSpan II to respond to PCI I/O space cycles.
This is a global bit, the PAS bit of each specific image also needs to be
set.
Appendix D: Software Initialization
QSpan II User Manual382 May 16, 20 13
Once the target images are programmed, PCI masters can read from and write to the
QBus address space.
PBTI0_CTL
and/or
PBTI1_CTL
EN Set this bit to enable the Target image.
PWEN Set this bit to 1 to allow write transactions to be posted; this improves
system throughput.
PREN Set this bit if the PCI Initiator is attempting to perform PCI burst reads.
This bit is used in conjunction with the PRCNTx field in the
MISC_CTL and MISC_CTL2 registers.
BRSTWREN Set this bit to enable the QSpan II to perform burst transactions when
configured as an MPC860 QBus master . See also the BURST_4 bit in
the MISC_CTL2 register on Table 130 on page 278.
INVEND This bit Inverts the endian state from the state of the QB_BOC bit.
BS[3:0] Block Size of Target Image (affects number of address lines translated).
PAS This bit allows the PCI Target Image to respond to a Memory or I/O
cycle. Typically, only Memory Space is implemented.
TC[3:0] This field determines how the TC[3:0] lines of the QSpan II are driven.
DSIZE[1:0] This field specifies the size of the destination port/memory on the
QBus.
PBTI0_ADDa
and/or
PBTI1_ADD
BA[31:16] This field specifies the base address of the PCI memory image which
the QSpan II monitors (see “Address Translation” on page 62).
TA[31:16] This field specifies part of the value for the translated local address (see
“Address Tr anslation” on page 62).
a. See also PCI_BST0 and PCI_BST1 registers in Appendix A: “Registers” on page 193.
Table 166: PCI Target Image Programming Summary (Continued)
Register Field Description
Appendix D: Software Initialization
QSpan II User Manual 383
May 16, 2013
D.5 Error Logging of Posted Transactions
QSpan II has registers which allow the processor to recover from a failed write cycle
from either the Px-FIFO or Qx-FIFO. This section discusses posted writes; delayed
reads and delayed writes are treated differently. QSpan II has the ability to log the failed
posted write cycle and generate an interrupt back to the PCI master or the QBus
processor. See “Terminations of Posted Writes” on page 82 for an explanation of error
recording in the PCI Target channel.
Similarly, error logging can be enabled for the QBus Slave Channel (see the following
table).
Table 167: QBus Error Logging Programming Summary
Register Field Description
QB_ERRCS ES Indicates if a failed cycle is currently logged.
EN Enable s error logging.
TC_ERR[3:0] Logs the status of the TC[3:0]of the failed cycle.
SIZ_ERR[1:0] Logs the SIZ[1:0] field of the failed cycle.
QB_AERR QAERR[31:0] Logs the 32-bit address of the failed transaction.
QB_DERR QDERR[31:0] Logs the 32-bits of data for the failed transaction.
Table 168: PCI Bus Error Logging Programming Summary
Register Field Description
PB_ERRCS ES Indicates if a failed cycle is currently logged.
EN Enable s error logging.
UNL_QSC Allows the PCI Interface to serve the QBus Slave Channel after an error
is logged.
CMD_ERR[3:0] Logs the PCI command for the failed cycle.
BE_ERR[3:0] Logs the status of the Byte Enables for the failed cycle.
PB_AERR PAERR[31:0] Logs the 32-bit address of the failed transaction.
PB_DERR PDERR[31:0] Logs the 32-bits of data for the failed transaction.
Appendix D: Software Initialization
QSpan II User Manual384 May 16, 20 13
D.6 IDMA/DMA Channel Initialization
The IDMA/DMA Channel has a single FIFO which can perform burst writes or burst
reads on the PCI Bus. During an IDMA cycle, the QSpan II is an IDMA peripheral
while either the MC68360 or the MPC860 is the bus master of the cycle. The MC68360
or the MPC860 must program three registers in order to initiate an IDMA transfer.
During DMA transfers, the QSpan II is the master on both the QBus and the PCI Bus.
See Chapter 5: “The IDMA Channel” on page 83 and Chapter 6: “The DMA Channel”
on page 93 for more information about register programming.
Interrupts can be generated based on different IDMA or DMA event types. The status
bits in the IDMA_CS or DMA_CS regis te r will cause an interrupt if enabled in the
INT_CTL register (see Chapter 8: “The Interrupt Channel” on page 113)
D.7 Interrupt Initialization
QSpan II has many different interrupting capabilities (See Chapter 8: “The Interrupt
Channel” on page 113 for a detailed discussion). These interrupt capabilities include:
software doorbells, mailboxes, error conditions, DMA completion, I2O, power
management, and hard ware interrupt sources. There are enable bits for each interrupt
source (INT_CTL register), interrupt direction (QBus or PCI) bits for each source
(INT_DIR register), and interrupt status bits for each source in the INT_STAT register.
Table 169: IDMA/DMA Channel Programming Summary
Register Field Description
IDMA/
DMA_PADD ADDR[31:2] The starting address of the IDMA/DMA transaction on the PCI bus.
IDMA/
DMA_CNT CNT[23:2] This register specifies the number of bytes which will be transferred.
IDMA/
DMA_CS (various) Fields in this register should be set according to the transaction
requirements (see Table 109 on page 246.)
DMA_QADD Q_ADDR[31:2] The starting address of the DMA transaction on the QBus.
DMA_CS (various) Fields in this register should be set according to the transaction
requirements (see Table 113 on page 252).
PCI_CS BM Enables the QSpan II to become the PCI bus master
Appendix D: Software Initialization
QSpan II User Manual 385
May 16, 2013
D.8 Generation of PCI Configuration and IACK Cycles
QSpan II can generate PCI Configuration cycles through a QBus master accessing
QSpan II registers. In order to generate a PCI Configuration read or write cycle, two
registers must be accessed. First, the Configuration Address register must be
programmed. Second, a write to the CON_DATA register is performed which causes
the PCI configuration write cycle to occur on the bus. In order to generate a PCI
Configuration read the QBus master should perform a read of the CON_DATA Register
(see “PCI Configuration Cycles Generated from the QBus” on page 108).
In order to generate a PCI IACK Cycle, the QBus processor should perform a read of
the IACK Cycle Generator Register (see “IACK_GEN” on page 259).
Table 170: PCI Configuration and IACK Cycle Programming Summary
Register Field Description
CON_ADD BUS_NUM[7:0] See the PCI 2.2 Specification and the QSpan II register descriptions.
DEV_NUM[3:0]
FUNC_NUM[2:0]
REG_NUM[5:0]
TYPE Determines whether the Configuration cycle generated is Type 0 or
Type 1.
CON_DATA CDATA[31:0] When this register is written to its contents are driven onto the PCI data
bus during a Configuration write cycle. The QBus master is retried until
the write completes on the PCI bus (for example, writes are delayed
transactions). A read of this register initiates a PCI Configuration read
cycle. The value returned from the PCI target is stored temporarily in
this register while waiting for the QBus master to perform an additional
read to obtain the data (for example, reads are also implemented as
delayed transactions).
MISC_CTL MA_BE_D This bit should be set to 1 so that when a PCI Master-Abort occurs
during a PCI Configuration cycle a normal data acknowledgement is
signaled to the QBus processor.
IACK_GEN IACK_VEC When the register is read, the QSpan II will perform a PCI IACK Cycle.
The QBus master is retried until the cycle completes on the PCI Bus.
The value from the PCI IACK is stored temporarily in this register
while waiting for the QBus master to perform an additional read to
obtain the vector.
Appendix D: Software Initialization
QSpan II User Manual386 May 16, 20 13
D.9 EEPROM and VPD Initialization
Many of the QSpan II’s operating parameters can be set by a serial EEPROM (see
Chapter 9: “The EEPROM Channel” on page 121). It is possible to program the serial
EEPROM by accessing a QSpan II register (EEPROM_CS). It is possible to program
Vital Product Data (VPD) information into the serial EEPROM by writing to the
PCI_VPD register. For additional programming details about EEPROM and VPD, see
Chapter 9: “The EEPROM Channel” on page 121.
D.10 I2O Messaging Unit Initialization
To initialize the I2O Messaging Unit, complete the following steps:
1. Start the QSpan II in PCI disable mode by setting the PCI_DIS bit to 1 in the
MISC_CTL2 register (see Table 130 on page 278).
2. Set the PCI_CLASS register from the EEPROM or the QBus processor (see
Table 71 on page 204).
3. Set the I2O_EN bit to 1 in the I2O_CS register (see Table 1 00 on page 236).
This bit moves the PCI_BSM register to offset 018h.
4. Clear the I20_EN bit.
5. Enable PCI access by clearing the PCI_DIS bit in the MISC_CTL2 register.
This allows the PCI Host to create the PCI memory map.
6. The QBus processor initializes the I2O Messaging Unit.
7. Set the I2O_EN bit to 1.
Appendix D: Software Initialization
QSpan II User Manual 387
May 16, 2013
D.11 PCI Expansion ROM Implementation
An Expansion ROM can be implemented on the QBus which will contain additi onal
information for the PCI host. In order for the PCI host to be able to read from this ROM,
the base address of this image must be programmed. This address can be programmed
from an external serial EEPROM.
Table 171: PCI Expansion ROM programming
Register Field Description
PCI_CS MS Set this bit before accessing the ROM.
PCI_BSROM BA[31:16] This field defines the base address for the expansion ROM.
EN Set this bit in order to use the expansion ROM image.
PBROM_CTL DSIZE[1:0] This field defines the size of the Expansion ROM (read only field,
programmed by serial EEPROM.
BS[2:0] This field defines the block size of the Expa nsion ROM image (read
only, programmed by serial EEPROM.
TC[3:0] This field defines how the QSpan II drives the TC lines (read only,
programmed by serial EEPROM.
TA[31:16] This field defines the Translation Address field (read only,
programmed by serial EEPROM.
Appendix D: Software Initialization
QSpan II User Manual388 May 16, 20 13
QSpan II User Manual 389
May 16, 2013
Appendix E: Endian Mapping
This appendix explains Endian Mapping for the QSpan II and Motorola processors. The
following topics are discussed:
“Big-Endian System” on page 390
“Little-Endian System” on page 39 1
“Endian Mapping Methods” on page 392
E.1 Overview
The PCI bus and the Motorola processors have some differences because of their unique
evolutionary histories. PCI was born in the Intel world, making it Little-Endian, while
the Motorola processors used Big-Endian.
Appendix E: Endian Mapping
QSpan II User Manual390 May 16, 20 13
E.2 Big-Endian System
In a Big-Endian system, the most significan t byte is located at the lowest address in
memory. When data is moved to the data bus, the least significant byte is moved to the
lowest byte lane (Byte 3 in lowest byte lane) and the most significant byte is moved to
the highest byte lane (Byte 0 in highest byte lan e). The follo wing figure sho ws a 4-byte
operand being moved to the data bus in a Big-Endian system.
Figure 80: Big-Endian System
Byte LanesMemory Organization
Byte 3
(LSB)
B(3)
03
Byte 2 Byte 0
(MSB)
Byte 1 Byte 3
(LSB)
Byte 0
(MSB)
Byte 1
Byte 2
B(0)
00
B(1)
01
B(2)
02
00
04
08
0C
07:00
31:24
23:16
15:08
Appendix E: Endian Mapping
QSpan II User Manual 391
May 16, 2013
E.3 Little-Endian System
In a Little-Endian system, the most significant byte is located at the highest address
location. When data is moved to the data bus, the least significant byte is moved to the
lowest byte lane (Byte 0 in lowest byte lane) and the most significant byte is moved to
the highest byte lane (Byte 3 in highest byte lane). It is important that the PCI bridge
provides flexibility in how endian systems are mapped across the interface. The
following figure shows a 4-byte operand bein g moved to the data bus in a Littl e-Endian
system.
Figure 81: Little-Endian System
Some host bus adapters (for example, SCSI) for the PCI environment expect their
descriptor blocks to be stored in main memory in Little-Endian format. This means that
a PCI-to-Motorola bridge must provide a flexible endian mapping scheme to allow for
PCI adapter control information to be stored in Motorola memory.
Byte 3
(MSB)
Memory Organization Byte Lanes
B(3)
03
Byte 2 Byte 0
(LSB)
Byte 1 Byte 0
(LSB)
Byte 3
(MSB)
Byte 2
Byte 1
B(0)
00
B(1)
01
B(2)
02
00
04
08
0C
07:00
31:24
23:16
15:08
Appendix E: Endian Mapping
QSpan II User Manual392 May 16, 20 13
E.4 Endian Mapping Methods
There are two standard approaches to endian mapping in a PCI-to-Motorola bridge:
address invariance and data invariance. A third approach involves using a combination
of both methods.
E.4.1 Address Invariance
With addre ss invariance, the addressing of the bytes in memory is preserved. The
following figure shows that by performing byte-lane swapping, the bytes appear in the
same address but their relative significance is not preserved. This method works for text
information but scrambles operands.
Figure 82: Address Invariant Mapping
Byte LanesMotorola Big Endian
B(3)
03
(MSB)(LSB) Byte 3
(LSB)
Byte 0
(MSB)
Byte 1
Byte 2
B(0)
00
B(1)
01
B(2)
02
00
04
08
0C
07:00
31:24
23:16
15:08
Byte 3
(MSB)
PCI Little Endian
B(3)
03
Byte 2 Byte 0
(LSB)
Byte 1Byte 3 Byte 2 Byte 0Byte 1
B(0)
00
B(1)
01
B(2)
02
00
04
08
0C
Byte 0
(LSB)
Byte 3
(MSB)
Byte 2
Byte 1
07:00
31:24
23:16
15:08
Appendix E: Endian Mapping
QSpan II User Manual 393
May 16, 2013
E.4.2 Data Invariance
The second approach is data invariance, which preserves the relative byte significance
but translates the byte addressing. The following figure shows that with data invariance,
Byte 0 is still the most significant byte in the data structure but is now located at address
03 in memory rather than address 00.
Figure 83: Data Invariant Mapping
E.4.3 Combined Method
By enforcing certain constraints on the system, it is possible to implement both options
in a PCI-to-Motorola bridge. By assuming that all data structures are 32-bit int egers, the
bridge could be powered up in either of these mapping modes. In address invariant
mode, byte lanes would be swapped (independent o f the data path width) assuming that
the bytes are part of a 32-bit word. In data invariant mode, the byte lanes would be
passed straight through assuming that the bytes are again part of a 32-bit word.
Byte Lanes
Byte 3
(LSB)
Motorola Big Endian
B(3)
03
Byte 2 Byte 0
(MSB)
Byte 1 Byte 3
(LSB)
Byte 0
(MSB)
Byte 1
Byte 2
B(0)
00
B(1)
01
B(2)
02
00
04
08
0C
07:00
31:24
23:16
15:08
Byte 0
(MSB)
PCI Little Endian
B(3)
03
Byte 1 Byte 3
(LSB)
Byte 2
B(0)
00
B(1)
01
B(2)
02
00
04
08
0C
Byte 3
(LSB)
Byte 0
(MSB)
Byte 1
Byte 2
07:00
31:24
23:16
15:08
Appendix E: Endian Mapping
QSpan II User Manual394 May 16, 20 13
QSpan II User Manual 395
May 16, 2013
Chapter 18: Operating and Storage Conditions
This appendix discusses operating and storage conditions for the QSpan II. The
following topics are discussed:
“Power Dissipation” on pa ge 395
“Operating Conditions” on page 396
“Thermal Characteristics” on page 396
18.1 Power Dissipation
Table 172: Power Dissipation
QCLKa
a. PCI clock always runs at 33 MHz.
Minimum Typical Maximum
25 MHz 0.28W 0.50W 0.63W
40 MHz 0.33W 0.58W 0.75W
50 MHz 0.38W 0.63W 0.90W
Chapter 18: Operating and Storage Conditions
QSpan II User Manual396 May 16, 20 13
18.2 Operating Conditions
18.3 Thermal Characteristics
The maximum ambient temperature of the QSpan II can be calculated as follows:
Ta Tj - ja* P
Where,
Ta = Ambient temperature (°C)
Tj = Maximum QSpan II Junction temperature (°C) = 125°C
ja = Junction to Ambient Thermal Impedance (°C / Watt) see Table 175.
P = QSpan II power consumption (Watts), see Table 172.
Table 173: 3.3 Volt Absolute Maximum Ratings
Symbol Parameter Rating Units
VDD DC Supply Voltage -0.5 to 7.0 V
VIN DC Input Voltage -0.3 to 5.3a b
a. Power available on VIO without power to VDD (VIN) can result in reliability impact.
b. QSpan II is 5V tolerant on all pins.
V
IIN DC Input Current 10 mA
TSTG Storage Temperature -40 to +125 °C
Ta ble 174: 3.3 Volt Recommended Operating Conditions
Symbol Parameter Rating Units
VDD DC Supply Voltage 3.0 to 3.6 V
TCCommercial Temperature 0 to 70 °C
TIIndustrial Temperature -40 to 85 °C
Chapter 18: Operating and Storage Conditions
QSpan II User Manual 397
May 16, 2013
The junction to ambient thermal impedance (ja) is dependent on the air flow in meters
per second over the QSpa n II (see Table 175).
Table 175: Junction to Ambient Characteristics
Wind Speed (m/s)
Package
Unit27 mm 17 mm
0 35.0 29.7 ja °C/W
1 32.4 25.8 ja °C/W
2 29.9 24.2 ja °C/W
Chapter 18: Operating and Storage Conditions
QSpan II User Manual398 May 16, 20 13
QSpan II User Manual 399
May 16, 2013
Appendix F: Mechanical Information
This appendix discusses mechanical (packaging) information for the QSpan II.
F.1 Mechanical Information
The following mechanical information is discussed:
QSpan II PBGA: 256-ball configuration, 17 mm package
QSpan II PBGA: 256-ball configuration, 27 mm package
F.1.1 256 PBGA — 17 mm
Table 176: 256 PBGA — 17 mm Packaging Features
Feature Description
Package Type 2 layer, 256 terminal Plastic Ball Grid Array (PBGA)
Package Body Size 17 X 17 mm
JEDEC Specification MO-151 Variation AAF-1
Appendix F: Mechanical Information
QSpan II User Manual400 May 16, 20 13
Figure 84: 256 PBGA, 17 mm — Top and Side Views
F.1.1.1 PBGA Notes — 17 mm
1. All dimensions conform to ANSI Y14.5-1994. Dim in millimeters (mm).
2. Measured at the maximum solder ball diameter parallel to primary datum Z.
3. Primary datum Z and seating plane are defined by the spherical crowns of the
solder balls.
4. A1 Corner is identified by chamfer , i nk mark, metallized mark, indentation or other
feature of the package body or lid.
5. Reference Specification: QSpan II conforms to Jedec Registered Outline drawing
MO-151 Variation AAF-1, except for these dimensions.
6. Ball pad is 0.4 mm diameter. IDT recommends customers PCB pad have same
diameter.
Appendix F: Mechanical Information
QSpan II User Manual 401
May 16, 2013
Figure 85: 256 PBGA, 17 mm — Bottom View
F.1.2 256 PBGA — 27 mm
Table 177: 256 PBGA — 27 mm Packaging Features
Feature Description
Package Type 256 terminal Plastic Ball Grid Array (PBGA),
(1) power and (1) ground plane
Package Body Size 27 X 27 mm
JEDEC Specification MO-151 Variation BAL-2
Appendix F: Mechanical Information
QSpan II User Manual402 May 16, 20 13
Figure 86: 256 PBGA, 27 mm — Top and Side Views
F.1.2.1 PBGA Notes — 27 mm
1. All dimensions conform to ANSI Y14.5-1994. Dim in millimeters (mm).
2. Measured at the maximum solder ball diameter parallel to primary datum Z.
3. Primary datum Z and seating plane are defined by the spherical crowns of the
solder balls.
4. A1 Ball Corner ID. Marked in ink for plate mold. Indent if Automold.
5. A1 Corner is identified by chamfer , i nk mark, metallized mark, indentation or other
feature of the package body or lid.
6. Reference Specification: QSpan II conforms to Jedec Registered Outline drawing
MO-151.
7. Ball pad is 0.60 mm diameter. IDT recommend’s customers PCB pad has same
diameter.
Appendix F: Mechanical Information
QSpan II User Manual 403
May 16, 2013
Figure 87: 256 PBGA, 27 mm — Bottom View
Appendix F: Mechanical Information
QSpan II User Manual404 May 16, 20 13
QSpan II User Manual 405
May 16, 2013
Appendix G: Ordering Information
This appendix discusses ordering information for the QSpan II.
G.1 Ordering Information
Table 178: Ordering Information
Part Number Frequencya
a. The QSpan II is compatible with all M68040 variants in large buffer mode up to 40 MHz. The QSpan is
compatible with all M68040 variants in small buffer mode up to 33 MHz.
Voltageb
b. The QSpan II supports universal PCI (3.3/5V tolerant inputs and 3.3/5V compliant output signaling).
Temperature Package
CA91L862A-50IL 33MHz MC68360
50MHz MPC860 3.3V -40° to 85°C 17 mm PBGA
CA91L862A-50ILV 33MHz MC68360
50MHz MPC860 3.3V -40° to 85°C 17 mm PBGA
CA91L862A-50IE 33MHz MC68360
50MHz MPC860 3.3V -40° to 85°C 27 mm PBGA
CA91L862A-50IEV 33MHz MC68360
50MHz MPC860 3.3V -40° to 85°C 27 mm PBGA
Appendix G: Ordering Information
QSpan II User Manual406 May 16, 20 13
G.2 Part Numbering Information
The IDT “CA” part numbering system is explained as follows.
( ) – Indicates optional characters.
CA – IDT product identifier.
NNNNNNN – Product number
SS(S) – Maximum operating frequency of the fastest interface in MHz. If the speed
of this interface exceeds 999 MHz then the number will be followed by a G, for
GHz (for example, a 10-GHz part would be marked as 10G).
E – Operating environment in which the product is guaranteed. This code may be
one of the following characters:
C - Commercial temperature range (0 to +70°C)
I - Industrial temperature range (-40 to +85°C)
E - Extended temperature range (-55 to +125°C)
J - Junction rated temperature range (0 to 105°C)
K - Junction rated extended temperature range (-40 to 105°C)
P – The Package type of the product:
B - Ceramic ball grid array (CBGA)
E - Plastic ball grid array (PBGA)
G - Ceramic pin grid array (CPGA)
J - Ultra ball grid array (EBGA), 1 mm pitch
K - Ultra ball grid array (EBGA), 1.27 mm pitch
L - Plastic ball grid array (PBGA), 1 mm pitch
M - Small outline integrated circuit (SOIC)
Q - Plastic quad flatpack
CA NNNNNNN - SS(S) E P G (Z#)
IDT “CA” product identifier
Product number
Operating frequency
Operating environment
Package type
Prototype version status
RoHS/Green compliance
Appendix G: Ordering Information
QSpan II User Manual 407
May 16, 2013
G – IDT “CA” products fit into one of three RoHS-compliance categories:
Y - RoHS Compliant (6of6) – These products contai n none of the six restricted
substances above the limits set in the EU Directive 2002/95/EC.
Y - RoHS Compliant (Flip Chip) – These products contain only one of the six
restricted substances: Lead (Pb). These flip-chip products are RoHS compliant
through the Lead exemption for Flip Chip technology, Commission Decision
2005/747/EC, which allows Lead in solders to complete a viable electrical
connection between semiconductor die an d carrier within integrated circuit
Flip Chip packages.
V - RoHS Compliant/Green - These products follow the above definitions for
RoHS Compliance and are de noted as Green as they contain no Halogens.
Z# – Prototype version stat us (optional). If a product is released as a proto type then
a “Z” is added to the end of the part number. Further revisions to the prototype
prior to production release would add a sequential numeric digit. For example, the
first prototype version of device would have a “Z,” a second version would have
“Z1,” and so on. The proto t ype version code is dropped once the product reaches
production status.
Appendix G: Ordering Information
QSpan II User Manual408 May 16, 20 13
QSpan II User Manual 409
May 16, 2013
Glossary
CompactPCI CompactPCI is an ad aptation of the PCI Specification for Industrial and
embedded applications requiring a more robust mechanical form factor than
desktop PCI.
Cycle Cycle refers to a single data beat; a transaction is composed of one or more
cycles.
DMA Direct Memory Access. A pr ocess for transferr ing data from main memory to
a device without passing it through the Host processor.
Master Master (initiator) is the owner of the PCI bus. It is used for both the QBus and
the PCI bus.
QBus QBus is a generic term which refers to the interface between the QSpan II and
the Host process or bu s to which QSpan I I is connected.
Slave Slave (target) i s the device whic h is accessed by the bus master. I t is reserved
for addresses ac cessed by PCI masters .
Slave Image Slave image is a memory range which is mapped on the QBus (Host processor
bus). Two slave images reside in the QSpan II QBus Slave Channel.
Target image Target image is a memory range which is mapped on the PCI bus. Two target
images reside in the QSpan II PCI Target Channel.
Glossary
QSpan II User Manual410 May 16, 20 13
QSpan II User Manual 411
May 16, 2013
Index
Numerics
17 x 17 mm package 399
27 x 27 mm package 401
A
A[31:0] 161, 165, 169, 181
ACT bit
EEPROM_CS Register 277
IDMA/DMA_CS Register 246
AD[31:0] 172, 181
ADDR field
EEPROM_CS Register 277
IDMA/DMA_PADD Register 249, 384
Address Phase
Configuration Cycle 109, 256
IDMA Channel 85, 87
QBus 37–41
Address Translation
PCI Target Channel 62
QBus Slave Channel 40
APS bit
PCI_PMC Register 217
Arbitration
PCI bus 40
QBus 76–78, 162, 165
Register Channel 103
Arbitration Scheme
PCI Bus Arbiter 140
AS_ 37, 39, 161, 181, 322
Assigning the Base Address 59, 62
AT[0:3] 165
AVEC_ 362, 374
B
BA bit
PCI_BSM Register 381
BA field
I2O_BAR Register 207
PBTI0_ADD Register 224, 382
PBTI1_ADD Register 228, 382
PCI_BSM Register 206
PCI_BSROM R eg is t er 213, 387
PCI_BST0 Register 208
PCI_BST1 Register 210
BASE field
PCI_CLASS Register 204
BB_/BGACK_ 78, 79, 161, 165, 169, 181
BDIP_ 57, 73, 156, 161, 165, 169, 181, 363,
368
BE_ERR field
PB_ERRCS Register 232, 383
BERR_/TEA_ 79, 162, 165, 169, 181
BG_ 76, 77, 78, 162, 165, 170, 181
BGACK_ 161
BISTC bit
PCI_MISC0 Register 205
BM bit
PCI_CS Register 108, 203, 384
BM_EN/FIFO_RDY_ 162, 166, 170, 181,
363
BM_PARK field
PARB_CTL Register 281, 380
Boundary scan support 25
BR_ 76, 77, 78, 162, 166, 170, 181
BRSTEN bit
DMA_CS Register 253
BRSTWEN bit
PBTI0_CTL Register 382
PBTI1_CTL Register 382
BRSTWREN bit
Bursting on the QBus 73
PBTI0_CTL Register 222
PBTI1_CTL Register 226
BS field
PBROM_CTL Register 230, 387
PBTI0_CTL Register 222, 382
Index
QSpan II User Manual412 May 16, 20 13
PBTI1_CTL Register 226, 382
QBSI0_AT Register 285, 380
QBSI1_AT Register 289, 380
Burst Transfer
PCI Target Channel 72–76
target-disconnect 80, 81
QBus Slave Channel 39, 51, 284, 287,
288
translation 44
write 47
BURST_/TIP_ 166, 170, 181
BURST_4 bit
DMA_CS Register 253
MISC_CTL2 Register 279, 379
Bus Error 32
burst 284, 288
IDMA 89, 89–91, 246, 260
INT_CTL register 263
INT_DIR register 266
INT_STAT register 260
logging (PCI Target Channel) 82
logging (QBus Slave Channel) 54
PB_DERR register 235
PB_ERRCS register 232
PCI Master Module 53
QB_ERRCS register 291
QBus Master Module 79
QBus Slave Module 51, 284, 288
burst 47, 48
signaling 52
QBus Slave Module (signaling) 52
translation (PCI Target Channel) 82
Bus Parking 40, 142
PCI Bus Arbiter 142
Bus Request 181
PCI bus 40, 174, 183
QBus 76, 162, 165
BUS_NUM field
CON_ADD Register 256, 385
Byte Lane (EEPROM) 127
C
C/BE[1] 181
C/BE[2] 181
C/BE[3] 181
C/BE#[3:0] 43, 172, 181
Cacheline 72, 81
CAP_ID field
CPCI_HS Register 219
PCI_PMC Register 217
PCI_VPD Reg i st er 220
CAP_L bit
PCI_CS Register 202
CAP_PT field
PCI_CP Register 215
Capacitors 158
CCODE field
PCI_MISC0 Register 205
CDATA field
CON_DATA Register 258, 385
CHAIN bit
IDMA/DMA_CS Register 247
Chip Select 162, 166, 170, 173
CLINE field
PCI_MISC0 Register 205
CLKO1 359
Clocking
M68040 373
PowerQUICC 366
QUICC 359
CMD bit
IDMA/DMA_CS Register 246
CMD_ERR field
PB_ERRCS Register 232, 383
CNT field
IDMA/DMA_CNT Register 250, 384
CompactPCI Hot Swap
Card Extraction 147
Card Insertion 145
CompactPCI Hot Swap Friendly 143
CON_ADD Register 256
DEV_NUM field 109
FUNC_NUM field 109
REG_NUM field 109
TYPE bit 109
CON_DATA Reg i s ter 258
CDATA field 109
Configuration Space
from PCI bus 62
from PCI bus (how to access) 385
from QBus 30, 37, 43, 47
from QBus (how to access) 108–110
IDMA Channel 84
PCI Target Channel 105
Register Channel 103
CP_LOC bit
Index
QSpan II User Manual 413
May 16, 2013
DMA_CS Register 253
CPCI_HS Register 219
CPP field
DMA_CPP 255
CSPCI_ 162, 166, 170, 181
CSREG_ 107, 162, 166, 170, 181
Customer Support Information 28
Cycle Termination
PCI Target Channel 78
QBus Slave Channel 51, 54
D
D_PE bit
PCI_CS Register 201
D[31:0] 162, 166, 170, 181
D1_SP bit
PCI_PMC Register 217
D2_SP bit
PCI_PMC Register 217
DACK_/SDACK_ 162, 166, 181
DATA field
EEPROM_CS Register 277
Data Packing/Unpacking 68
IDMA Channel 86, 87, 91
PCI Target Channel 68, 72
QBus Slave Channel 47
Data packing/unpacking
IDMA Channel 92
Data Parity Error (see Parity)
Data Phase
PCI Configuration Cycle 110
PCI Interface
and PAR 50
PCI Target Channel
burst 72
DC Characteristics 177
Decoupling Capacitors 158
Delayed Transfer
Configuration Cycles 32
PCI Target Channel 82
PCI Transaction Ordering 75
PWEN bit 72
single write 72, 73
write 81
QBus Slave Channel 30, 52
burst read 48
delayed write 51
PCI Transaction Ordering 49
single write 51
DEV_NUM field
CON_ADD Register 256, 385
DEV66 bit
PCI_CS Register 202
DEVSEL field
PCI_CS Register 201
DEVSEL# 44, 62, 81, 172, 181
DID field
PCI_ID Register 200
DIR bit
DMA_CS Register 252
IDMA/DMA_CS Register 247
Direct Mode
DMA Channel 94
discard timer 48
DMA Channel 31
Burst Cycles 96
description 93
Direct Mode 94, 97
DMA Cycles on QBus 97
Linked-List Mode 94, 98
Registers 95
DMA Registers 95
DMA_CPP Register 255
DMA_CS Register 252
DMA_QADD Register 251
Document Conventions
Bit Ordering 27
Document Status 28
Numeric Co nventions 27
Signals 27
Symbols 28
Typograhic Conventions 27
DONE bit
IDMA/DMA_CS Register 246
DONE_ 163, 166, 182
DONE_DIR bit
INT_DIR Register 266
DONE_EN bit
INT_CTL Register 263
DONE_IS bit
INT_STAT Register 260
DP_D bit
PCI_CS Register 116
DPNE_DIR bit
INT_DIR Register 267
DREQ_ 86, 163, 166, 182
Index
QSpan II User Manual414 May 16, 20 13
DS_ 163, 182
DSACK0_ 163, 182
DSACK1_/TA_ 163, 167, 170, 182
DSI bit
PCI_PMC Register 217
DSIZE bit
PBTI0_CTL Register 222
DSIZE field
DMA_CS Register 252
PBROM_CTL Register 230, 387
PBTI0_CTL Register 382
PBTI1_CTL Register 226, 382
Dual Address Cycle 85, 87, 322, 341
termination mode 248
timing 247, 326, 328
E
EEPROM
channel description 121–128
Control and Status Register 198
PCI_BST0 register enab led 208
PCI_BST1 register enab led 210
programming 127
SCL signal 175
SDA signal 175
EEPROM_CS Register 277
ADDR field 128
EIM bit
CPCI_HS Register 219
EN bit
PB_ERRCS Register 232, 383
PBTI0_CTL Register 222, 382
PBTI1_CTL Register 226, 382
PCI_BSROM Register 213, 387
QB_ERRCS Register 291, 383
QBSI0_AT Register 285, 380
QBSI1_AT Register 289, 380
Endian Issues
PCI Target Channel 66–71, 226, 252
QBus Slave Channel 44–45
Register Channel 108
Endian Mapping 389
ENID 175, 176, 182
ENUM# 174, 182
ES bit
PB_ERRCS Register 232, 383
QB_ERRCS Register 291, 383
Expansion ROM 213, 214, 230
EXT bit
CPCI_HS Register 219
EXT_GNT# 182
EXT_GNT#[6:1] 172
EXT_REQ# 182
EXT_REQ#[6:1] 173
F
FIFO_SIZE field
I2O_CS Register 237
FRAME# 62, 173, 182, 187
Frequency
PCLK 173
QCLK
M68040 171, 310
PowerQUICC 167, 306
QUICC 164, 301
IDMA fast termination 306, 325,
328
QUICC IDMA fast termination 164
FUNC_NUM field
CON_ADD Register 256, 385
Functional Diagram
QSpan II 30
G
GNT# 173, 182
GO bit
IDMA/DMA_CS Register 246
H
HALT_/TRETRY_ 163, 167, 182
Hot Swap Friendly 143
HS_HEALTHY_ 174, 182
HS_LED 174, 182
HS_SWITCH 174, 182
I
I/O Read 43, 44, 62
I/O Space
IDMA Channel 84
PCI Target Channel
burst 80
image programming 60, 62
QBus Slave Channel 30, 38
burst 47, 48, 51
image programming 38
I/O Write 43, 44, 62
Index
QSpan II User Manual 415
May 16, 2013
I2OInbound Messaging 132
Interrupts 137
Operation 134
Outbound Messaging 133
I2O Messaging Unit 131
I2O_BAR Register 207
I2O_CS Register 236
I2O_INQ Register 296
I2O_OPIM Register 295
I2O_OPIS Register 294
I2O_OUTQ Register 297
IACK_GEN Register 259
IACK_VEC field 119
IACK_VEC bit
IACK_GEN Register 385
IACK_VEC field
IACK_GEN Register 259
IDMA Channel
Endian issues 91–92
error (see Bus Error/IDMA)
interrupt (see Interrupt/IDMA)
port size 85, 86, 87, 247
reset 89, 246, 248
status 89
IDMA signals (direction) 322, 341
IDMA_ADD Register
ADDR field 85, 87
IDMA_CNT Register
IDMA_CNT field 86, 87, 88
IDMA_CS Register
ACT bit 89
DIR bit 85, 87
DONE bit 86, 87, 88, 89, 90, 116
GO bit 86, 87
IMODE bit 85
IPE bit 86, 87, 89, 90, 91, 116
IQE bit 89, 90, 91, 116
IRST bit 86, 87, 89, 90, 91, 115, 116
IRST_REQ bit 86, 88, 91
PORT16 bit 85, 87
QTERM bit 85, 87
STERM bit 85, 87
IDMA/DMA_CNT Register 250
IDMA/DMA_CS Register 246
IDMA/DMA_PADD Register 249
IDSEL 105, 173, 182
IF_BP field
IIF_BP Register 239
IF_E bit
I2O_CS Register 236
IF_F bit
I2O_CS Register 236
IF_TP field
IIF_TP Register 238
IFE_DIR bit
INT_DIR Register 267
IFE_EN bit
INT_CTL Register 265
IFE_S bit
INT_STAT Register 261
I-FIFO Watermark 87
IIF_BP Register 239
IIF_TP Register 238
IIP_BP Register 241
IIP_TP Register 240
IMODE bit
IDMA/DMA_CS Register 247
IMSEL 163, 167, 170, 182, 374
IN_Q field
I2O_INQ Register 296
INS bit
CPCI_HS Register 219
INT_CTL Register 263
DONE_EN bit 89, 90, 116
DPD_EN bit 50, 116
IPE_EN bit 90, 116
IQE_EN bit 89, 90, 116
IRST_EN bit 89, 90, 116
PEL_EN bit 54
QEL_EN bit 82, 116
SI0 bit 118
SI1 bit 118
INT_CTL2 Register 269
INT_DIR bit
INT_DIR Register 266
INT_DIR Register 266
DPD_DIR bit 116
IPE_DIR bit 90, 116
IQE_DIR bit 90, 116
IRST_DIR bit 90, 116
PEL_DIR bit 54
QEL_DIR bit 82, 116
SI0_DIR bit 118
SI1_DIR bit 118
INT_EN bit
Index
QSpan II User Manual416 May 16, 20 13
INT_CTL Register 264
INT_IS bit
INT_STAT Register 260
INT_LINE field
PCI_MISC1 Register 216
INT_PIN field
PCI_MISC1 Register 216
INT_STAT Register 260
DONE_IS bit 90, 116
DPD_IS bit 116
IPE_IS bit 90, 116
IQE_IS bit 90, 116
IRST_IS bit 90, 116
QEL_IS bit 116
SI0_IS bit 118
SI1_IS bit 118
INT# 115, 173, 182
Interrupt Acknowledge Cycle 43, 119
Interrupt Channel 32
address parity 75
description 113
IDMA Channel 89
interrupt enabling 116
interrupt mapping 116
interrupt sources 116
PCI Target Module posted writes 82
QBus slave module posted writes 54
INVEND bit
DMA_CS Register 252
PBTI0_CTL Register 222, 382
PBTI1_CTL Register 226, 382
IOF_BP Register 243
IOF_TP Register 242
IOP_BP Register 245
IOP_TP Register 244
IOS bit
PCI_CS Register 203, 381
IP_BP field
IIP_BP Register 241
IP_E bit
I2O_CS Register 236
IP_F bit
I2O_CS Register 236
IP_TP field
IIF_TP Register 240
IPE bit
IDMA/DMA_CS Register 246
IPE_DIR bit
INT_DIR Register 266
IPE_EN bit
INT_CTL Register 263
IPE_IS bit
INT_STAT Register 260
IPF_DIR bit
INT_DIR Register 267
IPF_EN bit
INT_CTL Register 265
IPF_S bit
INT_STAT Register 261
IPL[2:0] 374
IPN_DIR bit
INT_DIR Register 267
IPN_EN bit
INT_CTL Register 265
IPN_IS bit
INT_STAT Register 261
IQE bit
IDMA/DMA_CS Register 246
IQE_DIR bit
INT_DIR Register 266
IQE_EN bit
INT_CTL Register 263
IQE_IS bit
INT_STAT Register 260
IRDY# 173, 182
IRQ[7:1] 362, 369
IRST bit
IDMA/DMA_CS Register 246
IRST_DIR bit
INT_DIR Register 266
IRST_EN bit
INT_CTL Register 263
IRST_IS bit
INT_STAT Register 260
IRST_REQ bit
IDMA/DMA_CS Register 246
IWM field
DMA_CS Register 252
IDMA/DMA_CS Register 247
J
JTAG 25
K
KEEP_BB bit 73
MISC_CTL2 Register 278, 379
Index
QSpan II User Manual 417
May 16, 2013
L
LAYOUT field
PCI_MISC0 Register 205
Linear address incrementing 72
Linked-List Mode
DMA Channel 94
LOCK 56
LOO bit
CPCI_HS Register 219
LTIMER field
PCI_MISC0 Register 205
M
M68040 29, 156
bus arbitration 78
Compatibility of QSpan with variants of
373, 405
cycle termination 79
Interface 372
master and slave modes 156
signals 169
MA_BE_D bit
MISC_CTL Register 274, 378, 385
Mailbox Registers 112
Master-Abort 44, 51, 53, 54, 75
Master-Completion 51, 82
MAX_LAT field
PCI_MISC1 Register 216
MAX_RTRY field
MISC_CTL2 Register 278, 379
MB_DATA field
MBOX0 Register 270
MBOX1 Register 271
MBOX2 Register 272
MBOX3 Register 273
MB0_DIR bit
INT_DIR Register 267
MB0_EN bit
INT_CTL Register 264
MB0_IS bit
INT_STAT Register 261
MB1_DIR bit
INT_DIR Register 267
MB1_EN bit
INT_CTL Register 264
MB1_IS bit
INT_STAT Register 261
MB2_DIR bit
INT_DIR Register 267
MB2_EN bit
INT_CTL Register 264
MB2_IS bit
INT_STAT Register 261
MB3_DIR bit
INT_DIR Register 267
MB3_EN bit
INT_CTL Register 264
MB3_IS bit
INT_STAT Register 261
MBOX0 Register 270
MBOX1 Register 271
MBOX2 Register 272
MBOX3 Register 273
MC68302 24
MD_PED bit
PCI_CS Register 202
MDBS bit
DMA_CS Register 253
MDPED_DIR bit
INT_DIR Register 266
MDPED_EN
INT_CTL 263
MDPED_IS bit
INT_STAT Register 260
Mechanical Information 399
Memory Controller
M68040 374
PowerQUICC 368
QUICC 361
Memory Read 62
Memory Read Line 43, 62
Memory Read Multiple 43, 62
Memory Space
IDMA Channel 84
PCI Target Channel
image programming 60
QBus Slave Channel
burst 47, 48
image programming 38
Memory Write 43, 44, 62
Memory Write and Invalidate 43, 62
MFBBC bit
PCI_CS Register 202
MFUNCT bit
PCI_MISC0 Register 205
MIN_GNT field
Index
QSpan II User Manual418 May 16, 20 13
PCI_MISC1 Register 216
MISC_CTL Register 35, 274
MSTSLV field 35, 57, 156
QB_BOC bit 44, 66, 91
S_BB bit 77, 78
S_BG bit 77, 78
SW_RST bit 154
MISC_CTL register
QB_BOC bit 61
MISC_CTL2 Register 278
MS bit
PCI_CS Register 203, 381, 387
MSTSLV field
MISC_CTL Register 275, 378
MWI_EN bit
PCI_CS Register 203
Mx_PRI bit
PARB_CTL Register 281, 380
N
NOTO bit
MISC_CTL2 Register 379
NXT_IP field
CPCI_HS Register 219
PCI_PMC Register 217
PCI_VPD Register 220
O
OF_BP field
IOF_BP Register 243
OF_E bit
I2O_CS Register 236
OF_F bit
I2O_CS Register 236
OF_TP field
IOF_TP Register 242
OFE_DIR bit
INT_DIR Register 267
OFE_EN bit
INT_CTL Register 265
OFE_S bit
INT_STAT Register 261
OFF_DIR bit
INT_DIR Register 268
OFF_EN bit
INT_CTL Register 265
OFF_S bit
INT_STAT Register 262
OP_BP field
IOP_BP Register 245
OP_E bit
I2O_CS Register 236
OP_F bit
I2O_CS Register 237
OP_IM bit
I2O_OPIM Register 295
OP_ISR bit
I2O_OPIS Register 294
OP_TP field
IOP_TP Register 244
Open Drain Output 182, 183
OPNE bit
INT_STAT Register 261
OPNE_EN bit
INT_CTL Register 264
Ordering Information 405
OUT_Q field
I2O_OUTQ Register 297
P
P2P_BSE field
PCI_PMCS Register 218
PAERR field
PB_AERR Register 234, 383
PAR 50, 75, 173, 182
PARB_CTL Register 281
Parity
PCI Master Module
address parity 50
data parity 50
PCI Target Module
address parity 62, 75
data parity 75
register bits 50, 75, 201, 202, 266
summary 116
PARK bit
PARB_CTL Register 281, 380
PAS bit
PBTI0_CTL Register 222, 382
PBTI1_CTL Register 226, 382
PCI_BSIO Register 208
PCI_BST1 Register 210
QBSI0_CTL Register 283, 380
QBSI1_CTL Register 287, 380
PB_AERR Register 234
PAERR field 54
Index
QSpan II User Manual 419
May 16, 2013
PB_DERR 54
PB_DERR Register 235
PB_ERRCS 54
PB_ERRCS Register 232
BE_ERR field 54
CMDERR field 54
EN bit 53, 54
ES bit 54
PBROM_CTL Register 230
PBTI0_ADD Register 224
PBTI0_CTL Register 222
PBTI1_ADD Register 228
PBTI1_CTL Register 226
PBTIx_ADD
BA field 59
TA field 60
PBTIx_CTL Register
BS field 59
DSIZE field 57, 60, 66
EN bit 60
PAS bit 60
PWEN bit 60
TC field 60, 64
PCI Bus Arbiter 139
Arbitration Scheme 140
Bus Parking 142
PCI Interface 29
cycle types 43
PCI Master Module
defined 36
PCI Power Management Support 151
PME# 151
PCI Target Image
base address 59
block size 59
enabling 60
PCI address space 60
port size 60
posted write enabling 60
registers 224–229
transaction code 60
translation address 60
PCI Target Image 62
PCI Target Module 56
PCI Target Prefetch Disconnect 80
PCI_ARB_EN 175, 183
Reset Options 156
PCI_ARB_EN bit
PARB_CTL Register 281, 380
PCI_BSM Register 206
BA field 106
PCI_BSROM R eg is t er 213
PCI_BST0 Register 208
PCI_BST1 Register 210
PCI_BSTx Register
BA field 65, 66
PAS bit 65–66
PCI_CLASS Register 204
PCI_CP Register 215
PCI_CS Register 201
BM bit 108, 155, 162, 166, 170, 380
D_PE bit 50
DEVSEL field 62
DP_D bit 50, 116
MS bit 106
PERESP bit 50, 75
S_SERR bit 75
SERR_EN bit 75
PCI_DIS 175, 183
Reset Options 156
PCI_DIS bit
MISC_CTL2 Register 278, 379
PCI_ID Register 200
PCI_MISC0 Register 205
CLINE field 81, 85, 87, 90
PCI_MISC1 Register 216
PCI_PMC Register 217
PCI_PMCS Register 218
PCI_SID Register 212
SID field 125
SVID field 125
PCI_VPD Reg i st er 220, 221
PCLK 173, 183
PCSR_DIR bit
INT_DIR Register 266
PCSR_EN bit
INT_CTL Register 263
PCSR_IS bit
INT_STAT Register 260
PDERR field
PB_DERR Register 235, 383
PEL_DIR bit
INT_DIR Register 266
PEL_EN bit
INT_CTL Register 263
PEL_IS Register
Index
QSpan II User Manual420 May 16, 20 13
INT_STAT Register 260
PERESP bit
PCI_CS Register 202
PERR_DIR bit
INT_DIR Register 267
PERR_EN bit
INT_CTL Register 264
PERR_IS bit
INT_STAT Register 261
PERR# 50, 173, 183
P-FIFO 57
Pin-Out
17x17 mm Package 190, 191
Plug and Play 25
PM_VER field
PCI_PMC Register 217
PME_CLK bit
PCI_PMC Register 217
PME_EN bit
PCI_PMCS Register 218
PME_SP field
PCI_PMC Register 217
PME_ST bit
PCI_PMCS Register 218
PME# 151, 175, 183
Port Size
IDMA Channel 85, 86, 87
IDMA_CS register 85, 247
PBROM_CTL register 230
PBTI0_CTL register 222
PBTI1_CTL register 226, 252
PCI Target Image 60
PORT16 bit
IDMA/DMA_CS Register 247
Posted Write
error 54, 82
PCI Target Channel 72
enabling 60, 72
error logging 82
PCI transaction ordering 49–50
QBus Slave Channel 46–47
enabling 38
PCI transaction ordering 49
transaction ordering 50
Posted Write Termination
QBus Slave Channel
error logging 53
Power Dissipation 395
PowerQUICC 24, 29
Bus Arbitration 77
Connection Caution 41
cycle termination 52, 79
DONE signal 86
master and slave modes 156
signals 165
PowerQUICC Interface 365
Power-Up Options 153, 157
PR_CNT2 bit
MISC_CTL2 Register 379
PR_CNT2 field
MISC_CTL2 Register 279
PR_SING bit
MISC_CTL2 Register 61, 279, 379
PRCNT bit
MISC_CTL Register 378
PRCNT field
MISC_CTL Register 275
PREF bit
PCI_BSIO Register 208
PCI_BST1 Register 210
PREN bit
PBTI0_CTL Register 222, 382
PBTI1_CTL Register 226, 382
QBSI0_CTL Register 283, 380
QBSI1_CTL Register 287, 380
PROG field
PCI_CLASS Register 204
PSC_DIR bit
INT_DIR Register 267
PSC_EN bit
INT_CTL Register 264
PSC_IS bit
INT_STAT Register 261
PSC_QRST bit
MISC_CTL2 Register 280
PTC_PD bit
MISC_CTL2 Register 278, 379
PTP_IB bit
MISC_CTL2 Register 278, 379
Pull-Downs 157
Pull-Up
M68040 signals 374, 376
PowerQUICC signals 368
QUICC signals 52, 362, 363, 370
Pull-Ups 160
PWEN bit
Index
QSpan II User Manual 421
May 16, 2013
PBTI0_CTL Register 222, 382
PBTI1_CTL Register 226, 382
QBSI0_CTL Register 283, 380
QBSI1_CTL Register 287, 380
PWR_ST field
PCI_PMCS Register 218
Q
Q_ADDR field
DMA_CS Register 384
DMA_QADD Register 251
Q_OFF bit
DMA_CS Register 253
QAERR field
QB_AERR Register 292, 383
QB_AERR Register 292
QAERR field 82
QB_BOC bit
MISC_CTL Register 258, 259, 274, 378
QB_DERR Register 293
QDERR field 82
QB_ERRCS Register 291
EN bit 82
ES bit 82
SIZ_ERR field 82
TC_ERR field 82
QBSI0_AT Register 285
QBSI0_CTL Register 283
QBSI1_AT Register 289
QBSI1_CTL Register 287
QBSIx_AT Register
BS field 38, 40, 42, 59, 126
EN bit 38, 40
TA field 38, 40, 125
QBSIx_CTL Register
PAS bit 38, 43, 44, 47, 125
PWEN bit 38, 46, 47, 125
QBus
Bursting on the QBus 73
QBus (defined) 29
QBus Data Parity 35, 58
QBus Master Mode 57
QBus Master Module 57
QBus Slave Image 37–38
enable address translation 38
PCI address space 38
posted write enabling 38
registers 289
QBus Slave Mode 35, 57
QBus Slave Module 35
QCLK 164, 167, 171, 183
QDERR field
QB_DERR Register 293, 383
QDPE_DIR bit
INT_DIR Register 267
QDPE_EN bit
INT_CTL Register 264
QDPE_S bit
INT_STAT Register 261
QEL_DIR bit
INT_DIR Register 266
QEL_EN bit
INT_CTL Register 263
QEL_IS bit
INT_STAT Register 260
QIBA field
I2O_CS Register 236
IIF_BP Register 239
IIF_TP Register 238
IIP_BP Register 241
IIP_TP Register 240
IOF_BP Register 243
IOF_TP Register 242
IOP_BP Register 245
IOP_TP Register 244
QINT_ 115, 164, 167, 171, 183, 362, 374
QINT_DIR bit
INT_DIR Register 267
QINT_EN bit
INT_CTL Register 264
QINT_IS bit
INT_STAT Register 261
QINT_PME bit
MISC_CTL2 Register 280
QS_PRI bit
PARB_CTL Register 281, 380
QSC_PW bit
MISC_CTL2 Register 379
QSpan II Device Specific Registers 193
QTERM bit
IDMA/DMA_CS Register 247
QUICC
bus arbitration 76
cycle termination 78
master and slave modes 156
signals 161
Index
QSpan II User Manual422 May 16, 20 13
QUICC Interface 359
R
R_MA bit
PCI_CS Register 201
R_TA bit
PCI_CS Register 201
R/W_ 164, 167, 171, 183
READ bit
EEPROM_CS Register 277
Read Transactions 74
REG_AC bit
MISC_CTL2 Register 279, 379
REG_NUM field
CON_ADD Register 256, 385
Register Channel 31, 103–110
from PCI bus 105
from QBus 107–110
Register Map 195, 199
Related Documentation 28
REQ# 40, 174, 183
Reset
EEPROM 121
from PCI bus 174
options 153
QBus 164, 167
QSpan from QBus 167, 171
QSpan II from PCI bus 153
QSpan II from QBus 164
QSpan II through sofware 154
timing parameters 313
RESETH_ 373
RESETI_ 153, 164, 167, 171, 183
RESETO_ 153, 164, 167, 171, 183
Resets 153
IDMA Channel 89
RESETS_ 367
RID field
PCI_CLASS Register 204
RR_BP bit
I2O_CS Register 237
RST# 153, 174, 183
RSTI_ 373
S
S_BB bit
MISC_CTL Register 274, 378
S_BG bit
MISC_CTL Register 274, 378
S_SERR bit
PCI_CS Register 201
S_TA bit
PCI_CS Register 201
SBIST bit
PCI_MISC0 Register 205
SBO# 56
SC bit
PCI_CS Register 203
SCL 123, 157, 175, 183
SDA 123, 175, 183
SDACK_ 183
SDONE 56
SERR_DIR bit
INT_DIR Register 267
SERR_EN bit
INT_CTL Register 264
PCI_CS Register 202
SERR_IS bit
INT_STAT Register 261
SERR# 75, 174, 183
SI0 bit
INT_CTL Register 265
SI0_DIR bit
INT_DIR Register 268
SI0_IS bit
INT_STAT Register 262
SI1 bit
INT_CTL Register 265
SI1_DIR bit
INT_DIR Register 268
SI1_IS bit
INT_STAT Register 262
SI2 bit
INT_CTL2 Register 269
SI2_DIR bit
INT_DIR Register 268
SI2_IS bit
INT_STAT Register 262
SI3 bit
INT_CTL2 Register 269
SI3_DIR bit
INT_DIR Register 268
SI3_IS bit
INT_STAT Register 262
SID field
PCI_SID Register 212
Index
QSpan II User Manual 423
May 16, 2013
SIZ_ERR field
QB_ERRCS Register 291, 383
SIZ[1:0] 92, 119, 164, 168, 171, 183
size encoding (M6804 0) 172
size encoding (QUICC and PowerQUICC)
169
SIZ[1] 183
SIZ[3:0] 362
Software Initialization 377
EEPROM and VPD 386
Error Logging of Posted Transactions 383
Generation of PCI Configuration and IACK
Cycles 385
I2O Messaging Unit 386
IDMA/DMA Channel 384
Interrupt Initialization 384
Miscellaneous Control Register
Configuration 378
PCI Expansion ROM Implementation 387
PCI Target Channel 381
QBus Slave Channel 380
Register Access from the PCI Bus 381
SPACE bit
I2O_BAR Register 207
PCI_BSM Register 206
Special Cycle 43
STERM bit
IDMA/DMA_CS Register 247
STOP bit
DMA_CS Register 253
STOP_STAT bit
DMA_CS Register 253
STOP# 80, 81, 174, 183
SUB field
PCI_CLASS Register 204
SVID field
PCI_SID Register 212
SW_RST bit
MISC_CTL Register 274, 378
T
TA bit
PBTI1_ADD Register 382
TA field
PBROM_CTL Register 230, 387
PBTI0_ADD Register 224, 382
PBTI1_ADD Register 228
QBSI0_AT Register 285, 380
QBSI1_AT Register 289, 380
TA_ 168, 171, 183, 341
TA_BE_EN bit
MISC_CTL2 Register 279, 379
Target-Abort 51, 53, 80, 81, 82
defined 81
Target-Disconnect 51, 72, 80
defined 80
Target-Retry 51, 80
defined 81
TC field
DMA_CS Register 252
IDMA/DMA_CS Register 247
PBROM_CTL Register 230, 387
PBTI0_CTL Register 222, 382
PBTI1_CTL Register 226, 382
TC_EN bit
IDMA/DMA_CS Register 247
TC_ERR field
QB_ERRCS Register 291, 383
TC[1] 183
TC[2] 183
TC[3:0] 164, 168, 171, 183
TC[3] 183
TCK 176, 184
TDI 176, 184
TDO 176, 184
TEA_ 168, 172
Termination Mode (IDMA) 85, 87, 247
TEST1 175, 184
TEST2 175, 184
TEST3 175, 184
Test-Mode Operation 157
TFBBC bit
PCI_CS Register 202
TIP_ 172, 184
TM[2:0] 374
TMODE[0] 184
TMODE[1:0] 157, 175
TMODE[1] 184
TMS 184
Transaction Decoding
PCI Target Module 59, 66
QBus Slave Module 37
Transaction Ordering 49–50, 75–76
TRDY# 80, 81, 174, 184
TRETRY_ 168
TRST_ 176, 184
Index
QSpan II User Manual424 May 16, 20 13
TS_ 37, 39, 168, 184
TT[1:0] 374
TYPE bit
CON_ADD Register 256, 385
Typical Applications 359
U
UNL_QSC bit
PB_ERRCS Register 232
V
VGAPS bit
PCI_CS Register 203
VH 175
VID field
PCI_ID Register 200
Vital Product Data 128
VPD
Reading VPD Data 129
Writing VPD Data 129
VPD_ADDR field
PCI_VPD Register 220
VPD_DATA field
PCI_VPD Register 221
VPD_F bit
PCI_VPD Register 220
W
WAIT bit
PCI_CS Register 202
CORPORATE HEADQUARTERS
6024 Silver Creek Valley Road
San Jose, CA 95138
for SALES:
800-345-7015 or 408-284-8200
fax: 408-284-2775
www.idt.com
for Tech Support:
email: EHBhelp@idt.com
May 2013
DISCLAIMER Inte gr at ed Device Technol ogy, Inc. (IDT) and it s sub s id i ari es r ese rve th e r i ght to m o dify the products and/or specifica ti on s de scri b ed he re in at any time and a t ID T’ s sole di scr etion . All information in th i s do cum en t, i nclu di ng de scriptions of
product features and performance, is subject to change without notice. Performance specifications and the operating parameters of the described produ cts ar e d ete rm i ne d in the independe nt sta te a nd a re not gua ra nte ed t o pe rfo r m th e sam e way w he n
installed in cust omer p roduc ts. The in form ation co nta ined her ein is pro vided withou t represe ntat ion or warrant y of any kin d, wh ether expr ess or implied , includ ing, but n ot limited to, the sui tability of IDT’s products for any particu lar purp ose, an im plied
warranty of merchantability, or non-in fringement of the intellectual property rights of others. This document is presented only as a guide and does not convey any license under intellectual property rights of IDT or any third parties.
IDT’s products are not intended for use in life support systems or similar devices where the failure or malfunction of an IDT product can be reasonably expected to significantly affect the health or safety of users. Anyone using an IDT product in such a
manner does so at their own risk, absent an express, written agreement by IDT.
Integrated Device Technology, IDT and the IDT logo are registered trademarks of IDT. Other trademarks and service marks used herein, including protecte d names, logos and designs, are the property of IDT or their respective third pa rty owners.
Copyright May 2013. All rights reserved.