Molded Case Circuit Breakers List of products G-TWIN Standard Series (IEC/EN/GB/JIS conformed) Line protection Motor protection AC415V BW32 BW50 BW63 BW100 BW125 BW160 BW250 BW400 BW630 BW800 AC415V BW32 BW50 BW63 BW100 BW125 BW250 Icu Icu 1.5kA AAG AAG 2.5kA SAG EAG EAG AAG 7.5kA SAG SAG 10kA RAG RAG EAG 18kA EAG EAG 30kA JAG JAG JAG EAG 36kA SAG SAG SAG SAG EAG EAG RAG RAG RAG RAG RAG RAG HAG HAG HAG 50kA 65kA HAG* HAG* 1.5kA AAM 2.5kA SAM EAM EAM 7.5kA SAM SAM 10kA RAM EAM 18kA EAM 30kA JAM JAM 50kA RAM RAM HAG* 70kA Note: * There are no performance indications for GB standards for the BW50HAG, BW125HAG, and BW250HAG. G-TWIN Global Series (IEC/EN/GB/JIS/UL/CSA conformed) Line protection BW0 Series (IEC/EN/GB conformed) Line protection AC415V BW50 BW100 BW125 BW250 BW400 BW630 BW800 AC415V 100AF Icu Icu 10kA RAGU EAGU 250AF 18kA BW162E0 BW163E0 BW252E0 BW253E0 25kA BW162J0 BW163J0 BW252J0 BW253J0 BW162S0 BW163S0 BW252S0 BW253S0 15kA 18kA EAGU 30kA 160AF JAGU JAGU BW103E0 EAGU 36kA SAGU 50kA RAGU RAGU RAGU RAGU RAGU 70kA HAGU HAGU HAGU 30kA BW102S0 BW103S0 36kA S, H Series Line protection AC415V 50AF H Series Motor protection 100AF 225AF 400AF 600AF 800AF 1000AF 1200AF 1600AF Icu 65kA 06 AC415V 50AF Icu H52BA H53BA 85kA H102BA H103BA H202BA H203BA H103R H203R 125kA SA1003E SA1004E SA1203E SA1204E 65kA H53BAM SA1603E SA1604E H403R H603R H803R F Series Distribution Breakers AC240V 50AF 100AF Icu 3kA F51B F52B F53B F102B F103B Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/1 Molded Case Circuit Breakers G-TWIN series Type number nomenclature Type number nomenclature BW 250 EA G - 3P 225 X Series BW: G-TWIN series MCCB Frame size 32: 32AF 50: 50AF 63: 63AF 100: 100AF 125: 125AF 160: 160AF 250: 250AF 400: 400AF 630: 630AF 800: 800AF Breaking capacity Rated breaking capacity Icu (440V AC) 32AF 50AF 63AF 100AF 125AF 160AF 250AF 400AF 630AF 800AF AA EA JA SA RA HA 1.5kA 1.5kA - 1.5kA 1.5kA 2.5kA 2.5kA 10kA - - - - 2.5kA 7.5kA 7.5kA - - 10kA 10kA - - 65kA - - - - 30kA 36kA 50kA 65kA Model G: Line protection M: Motor protection G-TWIN series Blank: Standard U: Global No. of poles 2P: 2-pole 3P: 3-pole - 18kA 30kA 36kA 50kA - - 18kA 30kA 36kA 50kA 65kA - 30kA - 36kA 50kA 70kA - 36kA - - 50kA 70kA - 36kA - - 50kA 70kA 4P: 4-pole Rated current See page 06/29. Terminal combination (Global type) Terminal position Load Code Line Screw Blank Screw Flat teminal Blank Flat teminal Block terminal Block terminal SB Flat teminal Flat teminal SF Flat terminal Screw S3 Screw Flat teminal S4 Block terminal Screw S5 Block terminal Screw S6 Flat teminal Block terminal S7 Block terminal Flat terminal S8 06/2 Applicable breaker type BW50 BW100, 125, 250 - - - - - - - BW400, 630, 800 - - - - - - Mounting and connection * Standard type Blank: Front mounting front connection X: Front mounting rear connection E: Flush mounting rear connection Y: Flush mounting , top & buttom connection P: Plug-in mounting Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Type number nomenclature W K F R A Q2 M UC Enclosure UC: Standard UV: Dust-proof (IP40) UW: Rain-proof (IP54) With motor operating device (32 - 100AF) : DC100V AC100-110V AC200-220V Pad locking device Q2: Plate type Connection method (internal accessories) Blank: Lead-wire system A: Terminal block system Undervoltage trip device (External)* * 32/50/63/100AF : DC24V : DC100-110V : AC100V (50Hz) / AC100-110V (60Hz) : AC200V (50Hz) / AC200-220V (60Hz) : AC400V (50Hz) / AC400-440V (60Hz) Undervoltage trip device (Internal)* * 125/160/250AF * 400/630/800AF : DC24V AC/DC24V : DC48V AC/DC48V : DC100-110V AC/DC100-110V : DC125V AC120-130V / DC125V : AC100-110V AC200-240V / DC200-220V : AC110-130V AC277V : AC200-240V AC380-480V : AC277V : AC380-415V : AC440-480V Shunt trip device (Internal)* * 32/50/63/100AF : AC/DC24V : AC100-120V / DC100-110V : AC200-240V : AC380-450V Shunt trip device (Internal)* * 125/160/250AF * 400/630/800AF : AC/DC24V AC/DC24-48V : AC/DC48V AC100-240V / DC100-220V : AC100-120V / DC100-110V AC277V : AC120-130V AC380-550V : AC200-240V / DC200-220V : AC277V : AC380-440V : AC440-480V : AC500-550V Alarm switch* K: Standard SPDT J: Standard 2PDT 8: For low level circuit SPDT 9: For low level circuit 2PDT Auxiliary switch* W: Standard SPDT V: Standard 2PDT 1: For low level circuit SPDT 2: For low level circuit 2PDT * For the available configuration of accessory, see page 06/68. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/3 06 Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Standard Series Ampere frame 32A Type BW32AAG Pole 2 BW32SAG 3 2 Rated current Reference amb. temp. (40C) In(A) 3, 5, 10, 15, 20, 30, 32 Rated impulse withstand voltage Uimp(kV) 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 500 690 DC AC - 250*1 500V - 1.5/1 440V 1.5/1 2.5/2 415V 1.5/1 2.5/2 400V 1.5/1 2.5/2 380V 1.5/1 2.5/2 240V 2.5/2 5/3 230V 2.5/2 5/3 250V - 2.5/2*1 400V 1.5/1 2.5/2 230V 2.5/2 (TUV) 5/3 (TUV) Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 DC AC GB14048.2 Conforming to standards CE Marking 3 CCC certificate Electrical Appliance and Material Safety Law E*2 Dimensions (mm) a d c b a 50 b 100 100 c 60 60 d 84 Mass (kg) 0.4 Tripping device Hydraulic-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & bottom connection Y Plug-in mounting 50 75 84 0.5 0.4 0.5 - - - P IEC 35mm wide rail mounting Internal accessories No-mark Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type Operating handle V-type N V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier 75 Interphase BP Earth BL Handle locking cover L1 Flat terminal SS Block terminal SL - : Approved : Available -: Not available : Factory-mounted accessory Note: *1 Specify DC only when ordering circut breakers for DC circuit. 2 * Electrical Appliance and Material Safety Law of Japan 06/4 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Standard Series Ampere frame 50A Type BW50AAG BW50EAG BW50SAG BW50RAG BW50HAG Pole 2 2 2 2 2 3 3 3 3 Rated current Reference amb. temp. (40C) In(A) 5, 10, 15, 20, 30, 32, 40, 50 Rated impulse withstand voltage Uimp(kV) 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 500 690 690 690 690 DC AC - 250*1 250*1 250*1 250 500V - 1.5/1 5/3 7.5/4 25/7 440V 1.5/1 2.5/2 7.5/4 10/5 65/17 415V 1.5/1 2.5/2 7.5/4 10/5 65/17 400V 1.5/1 2.5/2 7.5/4 10/5 65/17 380V 1.5/1 2.5/2 7.5/4 10/5 65/17 240V 2.5/2 5/3 10/5 25/13 125/63 230V 2.5/2 5/3 10/5 25/13 125/63 250V - 2.5/2*1 5/3*1 5/3*1 40/20 400V 1.5/1 2.5/2 7.5/4 10/5 - 230V 2.5/2 (TUV) 5/3 (TUV) 10/5 (TUV) 25/13 (TUV) - Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 DC AC GB14048.2 Conforming to standards CE Marking 3 10, 15, 20, 30, 32, 40, 50 15, 20, 30, 40, 50 6 6 6 CCC certificate - Electrical Appliance and Material Safety Law E*2 Dimensions (mm) a d c b a 50 b 100 75 100 100 100 155 c 60 60 60 60 68 d 84 84 84 84 Mass (kg) 0.4 Tripping device Hydraulic-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC 35mm wide rail mounting Internal accessories 0.4 75 0.5 50 0.4 75 0.5 50 0.4 75 90 95 0.5 1.0 1.2 Thermal-magnetic No-mark - - - - - - Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Handle padlocking device Plate type Operating handle N-type Operating handle V-type Q1/QN Q2 N V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier 0.5 50 Interphase BP Earth BL Handle locking cover L1 Flat terminal SS Block terminal SL - - - - - - - - : Approved : Available -: Not available : Factory-mounted accessory Note: *1 Specify DC only when ordering circut breakers for DC circuit. 2 * Electrical Appliance and Material Safety Law of Japan Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/5 06 Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Standard Series Ampere frame 63A Type BW63EAG Pole 2 BW63SAG 3 2 BW63RAG 3 2 Rated current Reference amb. temp. (40C) In(A) 60, 63 Rated impulse withstand voltage Uimp(kV) 6 6 6 AC 690 690 690 DC AC 250*1 250*1 250*1 500V 1.5/1 5/3 7.5/4 440V 2.5/2 7.5/4 10/5 415V 2.5/2 7.5/4 10/5 400V 2.5/2 7.5/4 10/5 380V 2.5/2 7.5/4 10/5 240V 5/3 10/5 25/13 230V 5/3 10/5 25/13 250V 2.5/2*1 5/3*1 5/3*1 400V 2.5/2 7.5/4 10/5 230V 5/3 (TUV) 10/5 (TUV) 25/13 (TUV) Isolation compliant Rated insulation voltage Ui (V) Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 DC AC GB14048.2 Conforming to standards CE Marking 3 CCC certificate Electrical Appliance and Material Safety Law E*2 Dimensions (mm) a d c b a 50 b 100 75 100 100 c 60 60 60 d 84 84 Mass (kg) 0.4 Tripping device Hydraulic-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & bottom connection Y Plug-in mounting 75 50 75 84 0.4 0.5 0.4 0.5 - - - - P IEC 35mm wide rail mounting Internal accessories No-mark Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type Operating handle V-type N V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier 0.5 50 Interphase BP Earth BL Handle locking cover L1 Flat terminal SS Block terminal SL - - : Approved : Available -: Not available : Factory-mounted accessory Note: *1 Specify DC only when ordering circut breakers for DC circuit. 2 * Electrical Appliance and Material Safety Law of Japan 06/6 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Standard Series Ampere frame 100A Type BW100AAG Pole 2 BW100EAG 3 2 Rated current Reference amb. temp. (40C) In(A) 60, 63, 75, 100 50, 60, 63, 75, 100 Rated impulse withstand voltage Uimp(kV) 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 500 690 DC AC - 250*1 500V - 7.5/4 440V - 10/5 415V - 10/5 400V 1.5/1 10/5 380V 1.5/1 10/5 240V 5/3 25/13 230V 5/3 25/13 250V - 5/3*1 400V 1.5/1 10/5 230V 5/3 (TUV) 25/13 (TUV) Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 DC AC GB14048.2 Conforming to standards CE Marking 3 CCC certificate Electrical Appliance and Material Safety Law E*2 Dimensions (mm) a d c b a 50 b 100 100 c 60 60 d 84 Mass (kg) 0.4 Tripping device Thermal -magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & bottom connection Y Plug-in mounting 50 75 84 0.5 0.4 0.5 - - - 06 P IEC 35mm wide rail mounting Internal accessories No-mark Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type Operating handle V-type N V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier 75 Interphase BP Earth BL Handle locking cover L1 Flat terminal SS Block terminal SL - : Approved : Available -: Not available : Factory-mounted accessory Note: *1 Specify DC only when ordering circut breakers for DC circuit. 2 * Electrical Appliance and Material Safety Law of Japan Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/7 Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Standard Series Ampere frame 125A Type BW125JAG Pole 2 3 BW125SAG 4 2 3 BW125RAG 4 2 3 BW125HAG 4 2 3 Rated current Reference amb. temp. (40C) In(A) 15, 20, 30, 40, 50, 60, 75, 100, 125 Rated impulse withstand voltage Uimp(kV) 6 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 DC AC 250 250 250 250 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 DC AC GB14048.2 Conforming to standards 690V - - - - - 500V 5/3 8/4 10/5 10/5 25/7 440V 30/15 30/15 36/18 50/25 65/17 415V 30/15 30/15 36/18 50/25 65/17 400V 30/15 30/15 36/18 50/25 65/17 380V 30/15 30/15 36/18 50/25 65/17 240V 50/25 50/25 85/43 100/50 125/63 230V 50/25 50/25 85/43 100/50 125/63 250V 15/8 15/8 30/15 40/20 40/20 400V 30/15 30/15 36/18 50/25 - 230V 50/25 50/25 (TUV) 85/43 (TUV) 100/50 (TUV) - CE Marking CCC certificate - Electrical Appliance and Material Safety Law E*2 Dimensions (mm) a d c b (except for 125A) 90 b 155 155 155 155 c 68 68 68 68 d 95 95 95 Tripping device Thermal-magnetic Front mounting, front connection No-mark Front mounting, rear connection Flush mounting, front connection Plug-in mounting X E P Internal accessories 1.6 - 1.0 1.2 120 1.6 - 90 1.0 90 120 90 95 1.2 1.6 1.0 1.2 - Page 06/64 Alarm switch K Auxiliary switch W Undervoltage trip R - Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1 Handle padlocking device Plate type Q2 - Operating handle N-type Operating handle V-type N V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier 1.2 90 (except for 125A) 60 0.8 90 (except for 125A) a Mass (kg) 120 (except for 125A) Interphase Handle locking cover Flat terminal Block terminal BP L1 SS SL : Approved : Available -: Not available Note: * Electrical Appliance and Material Safety Law of Japan 06/8 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Standard Series Ampere frame 160A Type BW160EAG Pole 2 BW160JAG 3 2 3 BW160SAG 4 2 3 BW160RAG 4 2 Rated current Reference amb. temp. (40C) In(A) 125, 150, 160 Rated impulse withstand voltage Uimp(kV) 6 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 DC AC 250 250 250 250 690V - - - - 500V 5/3 8/4 10/5 10/5 440V 18/9 30/15 36/18 50/25 415V 18/9 30/15 36/18 50/25 400V 18/9 30/15 36/18 50/25 380V 18/9 30/15 36/18 50/25 240V 36/18 50/25 85/43 100/50 230V 36/18 50/25 85/43 100/50 250V 10/5 20/10 30/15 30/15 400V 18/9 30/15 36/18 50/25 230V 36/18 (TUV) 50/25 (TUV) 85/43 (TUV) 100/50 (TUV) Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 DC AC GB14048.2 Conforming to standards CE Marking 4 105 140 1.6 2.2 CCC certificate Electrical Appliance and Material Safety Law E* - Dimensions (mm) a d c b - b 165 165 165 165 c 68 68 68 68 d 95 95 95 Tripping device 1.6 105 1.4 105 1.6 140 2.2 105 - 105 1.4 105 - a Mass (kg) 1.4 105 140 105 95 1.6 2.2 1.4 Thermal-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Plug-in mounting P Internal accessories - - - Page 06/64 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1 Handle padlocking device Plate type Q2 Operating handle N-type Operating handle V-type N V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier 3 Interphase BP Handle locking cover L1 Flat terminal SS Block terminal SL : Approved : Available -: Not available Note: * Electrical Appliance and Material Safety Law of Japan Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/9 06 Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Standard Series Ampere frame 250A Type BW250EAG Pole Rated current Reference amb. temp. (40C) In(A) 2 3 2 175, 200, 225, 250 Rated impulse withstand voltage Uimp(kV) 6 6 6 6 6 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 690 DC AC 250 250 250 250 250 690V - - - - - 500V 5/3 8/4 10/5 10/5 25/7 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 DC AC GB14048.2 Conforming to standards BW250JAG BW250SAG 4 2 3 BW250RAG 4 2 3 BW250HAG 4 440V 18/9 30/15 36/18 50/25 65/17 18/9 30/15 36/18 50/25 65/17 400V 18/9 30/15 36/18 50/25 65/17 380V 18/9 30/15 36/18 50/25 65/17 240V 36/18 50/25 85/43 100/50 125/63 230V 36/18 50/25 85/43 100/50 125/63 40/20 250V 10/5 20/10 30/15 30/15 400V 18/9 30/15 36/18 50/25 - 230V 36/18 (TUV) 50/25 (TUV) 85/43 (TUV) 100/50 (TUV) - - - - - CE Marking CCC certificate Dimensions (mm) d c b a 105 b 165 105 105 105 140 165 105 105 140 165 105 105 140 165 105 165 c 68 68 68 68 68 d 95 95 95 95 95 Mass (kg) 1.4 Tripping device Thermal-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E P Internal accessories 3 - a Plug-in mounting 2 125,150,160,175 200,225,250 415V Electrical Appliance and Material Safety Law E* - 1.6 1.4 1.6 2.2 - 1.4 1.6 2.2 - 1.4 1.6 2.2 1.4 1.6 - Page 06/64 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1 Handle padlocking device Plate type Q2 Operating handle N-type Operating handle V-type N V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier 3 Interphase BP Handle locking cover L1 Flat terminal SS Block terminal SL : Approved : Available -: Not available Note: * Electrical Appliance and Material Safety Law of Japan 06/10 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Standard Series Ampere frame 400A Type BW400EAG Pole 2 BW400SAG 3 2 BW400RAG 3 2 3 BW400HAG 4 2 Rated current Reference amb. temp. (40C) In(A) 250, 300, 350, 400 Rated impulse withstand voltage Uimp(kV) 8 8 8 8 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 DC AC 250 250 250 250 690V - 10/5 15/8 15/8 500V 18/9 20/10 36/18 42/21 440V 30/15 36/18 50/25 70/35 415V 30/15 36/18 50/25 70/35 400V 30/15 36/18 50/25 70/35 380V 30/15 36/18 50/25 70/35 240V 50/25 85/43 100/50 125/63 230V 50/25 85/43 100/50 125/63 250V 20/10 20/10 40/20 40/20 400V 30/15 36/18 50/25 70/35 230V 50/25 (TUV) 85/43 (TUV) 100/50 (TUV) 125/63 (TUV) Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 DC AC GB14048.2 Conforming to standards CE Marking 4 140 185 5.6 7.4 CCC certificate Electrical Appliance and Material Safety Law E*1 - Dimensions (mm) a d c b - b 257 257 257 257 c 103 103 103 103 d 146 146 146 Tripping device 5.6 140 4.6 140 - 140 4.6 140 - a Mass (kg) 5.6 140 4.6 140 185 140 146 5.6 7.4 4.6 Thermal-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Plug-in mounting P Internal accessories - - Page 06/65 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type Operating handle V-type N V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier 3 Interphase BP Handle locking cover L1 Flat terminal SS Block terminal SL *2 *2 *2 *2 *2 *2 *2 *2 *2 *2 : Approved : Available -: Not available Note: *1 Electrical Appliance and Material Safety Law of Japan *2 Standard provided Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/11 06 Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Standard Series Ampere frame 630A Type BW630EAG BW630RAG BW630HAG BW800EAG 800A BW800RAG BW800HAG Pole 3 3 3 3 3 3 4 4 4 4 Rated current Reference amb. temp. (40C) In(A) 500, 600, 630 Rated impulse withstand voltage Uimp(kV) 8 8 8 8 8 8 Isolation compliant Rated insulation voltage Ui (V) AC 690 690 690 690 690 690 DC AC 250 250 250 250 250 250 690V - 15/8 15/8 - 15/8 15/8 600V - - - - - - 500V 18/9 36/18 42/21 18/9 36/18 42/21 440V 36/18 50/25 70/35 36/18 50/25 70/35 415V 36/18 50/25 70/35 36/18 50/25 70/35 400V 36/18 50/25 70/35 36/18 50/25 70/35 380V 36/18 50/25 70/35 36/18 50/25 70/35 240V 50/25 100/50 125/63 50/25 100/50 125/63 230V 50/25 100/50 125/63 50/25 100/50 125/63 250V 20/10 40/20 40/20 20/10 40/20 40/20 400V 36/18 50/25 70/35 36/18 50/25 70/35 230V 50/25 (TUV) 100/50 (TUV) 125/63 (TUV) 50/25 (TUV) 100/50 (TUV) 125/63 (TUV) - - 210 210 275 275 275 103 Rated breaking capacity Icu/Ics (kA) IEC 60947-2 EN 60947-2 JIS C 8201-2-1 DC AC GB14048.2 Conforming to standards CE Marking 700, 800 CCC certificate Electrical Appliance and Material Safety Law E*1 - Dimensions (mm) a d c b - - a 210 210 b 275 275 280 210 280 275 - c 103 103 103 103 103 d 146 146 146 146 146 Mass (kg) 7.8 7.8 8.3 8.3 Tripping device Thermal-magnetic Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Plug-in mounting P Internal accessories K Auxiliary switch W Undervoltage trip R Shunt trip - 10.3 - 280 146 11 8.3 - 11 - F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type Operating handle V-type Insulation barrier 7.8 210 Page 06/65 Alarm switch Terminal cover 10.3 280 Long Interphase N V BT L BP Handle locking cover L1 Flat terminal SS Block terminal SL *2 *2 *2 *2 *2 *2 : Approved : Available -: Not available Note: *1 Electrical Appliance and Material Safety Law of Japan *2 Standard provided 06/12 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Global Series Ampere frame Type Pole Rated current Reference amb. temp. (40C) Rated impulse withstand voltage Isolation compliant Rated insulation voltage Ui (V) Rated breaking IEC 60947-2 capacity EN 60947-2 JIS C 8201-2-1 Icu/Ics (kA) GB14048.2 Icu/Ics(kA) In(A) Uimp(kV) AC AC AC 500V 440V 415V 400V 380V 240V 230V 400V 230V 240V UL489 AC CAN/CSA C22.2 NO.5 (kA) Conforming to CE Marking standards CCC certificate UL Listed (NEMA AB1) Electrical Appliance and Material Safety Law E*1 Dimensions (inch(mm)) a a d c b b c d Mass (kg) Tripping device Connecting terminal Page 06/26 Screw S Flat Block Internal accessories Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 50A BW50RAGU 2 3 3, 5 10, 15, 20, 30, 32, 40, 50 3, 5 10, 15, 20, 30, 32, 40, 50 6 100A BW100EAGU 2 3 60, 63, 70, 75, 80, 90, 100 6 690 7.5/4 10/5 10/5 10/5 10/5 25/13 25/13 7/4 10/5 14/7 25/13 14 690 7.5/4 10/5 10/5 10/5 10/5 25/13 25/13 10/5 25/13 14 7/4 10/5 14/7 25/13 - (TUV) (TUV) 1.969 (50) 4.724 (120) 2.362 (60) 3.307 (84) 0.5 Hydraulic-magnetic 2.953 (75) - - 0.6 1.969 (50) 4.724 (120) 2.362 (60) 3.307 (84) 0.5 2.953 (75) 0.6 06 *2 : Approved : Available -: Not available Note: *1 Electrical Appliance and Material Safety Law of Japan 2 * Standard provided Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/13 Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Global Series Ampere frame Type Pole Rated current Reference amb. temp. (40C) Rated impulse withstand voltage Isolation compliant Rated insulation voltage Ui (V) Rated breaking capacity IEC 60947-2 EN 60947-2 JIS C 8201-2-1 Icu/Ics (kA) GB14048.2 Icu/Ics(kA) In(A) Uimp(kV) AC DC AC DC AC UL489 AC CAN/CSA C22.2 NO.5 (kA) 690 250 690V - 500V 15/8 440V 30/15 415V 30/15 400V 30/15 380V 30/15 240V 50/25 230V 50/25 250V 15/8 400V 30/15 230V 50/25 600V/Y 10 480V/ - 480V/Y 30 240V 50 125/250V 10 (TUV) DC CE Marking CCC certificate UL Listed (NEMA AB1) Electrical Appliance and Material Safety Law E* Dimensions (inch(mm)) a a d c b b c d Mass (kg) Tripping device Connecting terminal Page 06/26 Screw S Flat Block Internal accessories Page 06/64 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1 Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Operating handle F-type F Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 Conforming to standards 125A BW125JAGU 2 3 15, 20, 30, 40, 50, 60, 70, 75, 80, 90, 100, 125 6 (except for 125A) 2.362 (60) 6.732 (171) 2.677 (68) 3.740 (95) 0.8 Thermal-magnetic 3 6 690 250 5/3 36/18 50/25 50/25 50/25 50/25 100/50 100/50 40/20 50/25 100/50 18 50 50 100 10 (TUV) 10 30 30 50 10 3.543 (90) 1.2 BW125RAGU 2 (except for 125A) 3.543 (90) 6.732 (171) 2.677 (68) 3.740 (95) 1.0 1.2 - - - - : Approved : Available -: Not available Note: * Electrical Appliance and Material Safety Law of Japan 06/14 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Global Series Ampere frame Type Pole Rated current Reference amb. temp. (40C) Rated impulse withstand voltage Isolation compliant Rated insulation voltage Ui (V) Rated breaking capacity IEC 60947-2 EN 60947-2 JIS C 8201-2-1 Icu/Ics (kA) GB14048.2 Icu/Ics(kA) In(A) Uimp(kV) AC DC AC DC AC UL489 AC CAN/CSA C22.2 NO.5 (kA) 690 250 690V - 500V 10/5 440V 18/9 415V 18/9 400V 18/9 380V 18/9 240V 36/18 230V 36/18 250V 10/5 400V 18/9 230V 36/18 600V/Y - 480V/ - 480V/Y - 240V 22 125/250V 10 (TUV) DC CE Marking CCC certificate UL Listed (NEMA AB1) Electrical Appliance and Material Safety Law E* Dimensions (inch(mm)) a a d c b b c d Mass (kg) Tripping device Connecting terminal Page 06/26 Screw S Flat Block Internal accessories Page 06/64 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1 Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Operating handle F-type F Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 Conforming to standards 250A BW250EAGU BW250JAGU 2 3 2 125, 150, 160, 175, 200, 225, 250 6 6 - 4.134 (105) 7.126 (181) 2.677 (68) 3.740 (95) 1.4 1.6 Thermal-magnetic 3 BW250RAGU 2 3 6 690 250 - 18/9 30/15 30/15 30/15 30/15 50/25 50/25 20/10 30/15 50/25 10 30 30 50 10 (TUV) 690 250 5/3 36/18 50/25 50/25 50/25 50/25 100/50 100/50 40/20 50/25 100/50 25 50 50 100 10 (TUV) - 4.134 (105) 7.126 (181) 2.677 (68) 3.740 (95) 1.4 - 4.134 (105) 7.126 (181) 2.677 (68) 3.740 (95) 1.4 1.6 06 1.6 : Approved : Available -: Not available Note: * Electrical Appliance and Material Safety Law of Japan Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/15 Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Global Series Ampere frame Type Pole Rated current Reference amb. temp. (40C) Rated impulse withstand voltage Isolation compliant Rated insulation voltage Ui (V) Rated breaking capacity IEC 60947-2 EN 60947-2 JIS C 8201-2-1 Icu/Ics (kA) GB14048.2 Icu/Ics(kA) BW400SAGU 2 3 BW400RAGU 2 3 BW400HAGU 2 3 8 8 8 690 250 690V - 500V 18/9 440V 30/15 415V 30/15 400V 30/15 380V 30/15 240V 50/25 230V 50/25 250V 20/10 400V 30/15 230V 50/25 600V/ - 600V/Y - 480V/ - 690 250 10/5 20/10 36/18 36/18 36/18 36/18 85/43 85/43 20/10 36/18 85/43 - - 35 690 250 15/8 36/18 50/25 50/25 50/25 50/25 100/50 100/50 40/20 50/25 100/50 - - 50 480V/Y - 35 50 240V 22 125/250V 10 50 10 100 10 (TUV) 690 250 15/8 42/21 70/35 70/35 70/35 70/35 125/63 125/63 40/20 70/35 125/63 25 25 65 (With block terminal:50) 65 (With block terminal:50) 125 10 (TUV) - 5.512 (140) 10.12 (257) 4.055 (103) 5.748 (146) 4.6 5.6 - 5.512 (140) 10.12 (257) 4.055 (103) 5.748 (146) 4.6 5.6 In(A) Uimp(kV) AC DC AC DC AC UL489 AC CAN/CSA C22.2 NO.5 (kA) DC 400A BW400EAGU 2 3 250, 300, 350, 400 8 CE Marking CCC certificate UL Listed (NEMA AB1) Electrical Appliance and Material Safety Law E* Dimensions (inch(mm)) a a d c b b c d Mass (kg) Tripping device Connecting terminal Page 06/26 Flat Block Internal accessories Page 06/65 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Operating handle F-type F Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 (TUV) Conforming to standards - 5.512 (140) 10.12 (257) 4.055 (103) 5.748 (146) 4.6 5.6 Thermal-magnetic (TUV) - 5.512 (140) 10.12 (257) 4.055 (103) 5.748 (146) 4.6 5.6 : Approved : Available -: Not available Note: * Electrical Appliance and Material Safety Law of Japan 06/16 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide G-TWIN Global Series Ampere frame Type Pole Rated current Reference amb. temp. (40C) Rated impulse withstand voltage Isolation compliant Rated insulation voltage Ui (V) Rated breaking capacity IEC 60947-2 EN 60947-2 JIS C 8201-2-1 Icu/Ics (kA) GB14048.2 Icu/Ics(kA) In(A) Uimp(kV) AC DC AC DC AC UL489 AC CAN/CSA C22.2 NO.5 (kA) 630A BW630RAGU 3 500, 600, 630*1 8 690 250 690V 15/8 500V 36/18 440V 50/25 415V 50/25 400V 50/25 380V 50/25 240V 100/50 230V 100/50 250V 40/20 400V 50/25 230V 100/50 600V/ - 600V/Y - 480V/ 50 480V/Y - DC Conforming to standards 240V 100 125/250V 10 (TUV) CE Marking CCC certificate UL Listed (NEMA AB1) Electrical Appliance and Material Safety Law E*3 Dimensions (inch(mm)) a a d c b b c d Mass (kg) Tripping device Connecting terminal Page 06/26 Flat Block Internal accessories Page 06/65 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover BT L Insulation barrier Interphase BP Handle locking cover L1 BW630HAGU 3 8 690 250 15/8 42/21 70/35 70/35 70/35 70/35 125/63 125/63 40/20 70/35 125/63 25 25 65 (With block terminal:50) 65 (With block terminal:50) 125 10 (TUV) 800A BW800RAGU 3 700, 800*2 8 690 250 15/8 36/18 50/25 50/25 50/25 50/25 100/50 100/50 40/20 50/25 100/50 - - 50 50 100 10 (TUV) BW800HAGU 3 8 690 250 15/8 42/21 70/35 70/35 70/35 70/35 125/63 125/63 40/20 70/35 125/63 25 25 65 (With block terminal:50) 65 (With block terminal:50) 125 10 (TUV) 06 - 8.268 (210) 10.83 (275) 4.055 (103) 5.748 (146) 8.9 Thermal-magnetic - 8.268 (210) 10.83 (275) 4.055 (103) 5.748 (146) 8.9 - 8.268 (210) 10.83 (275) 4.055 (103) 5.748 (146) 9.4 - 8.268 (210) 10.83 (275) 4.055 (103) 5.748 (146) 9.4 : Approved : Available -: Not available Note: *1 Breakers for 630A cannot be manufactured with block terminals. *2 Block terminals are standard for Breakers for 800A. *3 Electrical Appliance and Material Safety Law of Japan Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/17 Molded Case Circuit Breakers G-TWIN series Quick reference guide Motor protection breakers Motors are nor mally controlled by MCCBs and magnetic starters. In this case the MCCB carries out overcurrent or short-circuit current protection while the starter deals with ON-OFF switching n G-TWIN of the motor and offers protection against sustained overload currents. These are the motor breakers which combine the two functions. FUJI motor breakers are designed to eliminate erroneous operations due to the rush current produced at the time of starting the motor. They will trip in the face of sustained overcurrent when the integrated bimetal relay has operated. Standard Series / Motor protection Ampere frame Type Pole Rated current Reference amb. temp. (40C) Rated impulse withstand voltage Isolation compliant Rated insulation voltage Ui (V) Rated breaking IEC 60947-2 capacity EN 60947-2 Icu/Ics (kA) JIS C 8201-2-1 GB14048.2 In(A) 32A BW32AAM 3 1.4, 2.6, 4, 8, 10, 16, 24, 32 BW32SAM 2 (2), (4), 5, 8, 10, 16 Uimp(kV) 6 6 3 0.7, 1.4, 2, 2.6, 4, 5, 8, 10, 12, 16, 24, 32 6 AC AC 500 - - 1.5/1 1.5/1 1.5/1 1.5/1 2.5/2 2.5/2 1.5/1 2.5/2 690 - 1.5/1 2.5/2 2.5/2 2.5/2 2.5/2 5/3 5/3 2.5/2 5/3 690 - 1.5/1 2.5/2 2.5/2 2.5/2 2.5/2 5/3 5/3 2.5/2 5/3 75 100 60 84 0.5 Hydraulic-magnetic 50 100 60 84 0.4 Hydraulic-magnetic 75 100 60 84 0.5 Hydraulic-magnetic - - - AC 690V 500V 440V 415V 400V 380V 240V 230V 400V 230V Conforming to standards CE Marking CCC certificate Electrical Appliance and Material Safety Law E*2 Dimensions (mm) a a d c b c b d Mass (kg) Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & buttom connection Y Plug-in mounting P IEC 35mm wide rail mounting Internal accessories Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Insulation barrier Earth BL Handle locking cover L1 Flat terminal SS Block terminal SL : Approved : Available -: Not available : Factory-mounted accessory Note: *1Specify DC only when ordering circuit breakers for DC circuit. *2Electrical Appliance and Material Safety Law of Japan 06/18 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide n G-TWIN Standard Series / Motor protection Ampere frame Type Pole Rated current Reference amb. temp. (40C) Rated impulse withstand voltage Isolation compliant Rated insulation voltage Ui (V) Rated breaking IEC 60947-2 capacity EN 60947-2 Icu/Ics (kA) JIS C 8201-2-1 GB14048.2 In(A) 50A BW50EAM 3 24, 32, 40, 45 Uimp(kV) 6 BW50SAM 3 0.7, 1.4, 2, 2.6, 4, 5, 8, 10, 12, 16, 24, 32, 40, 45 6 AC AC 500 - 1.5/1 2.5/2 2.5/2 2.5/2 2.5/2 5/3 5/3 2.5/2 5/3 690 - 5/3 7.5/4 7.5/4 7.5/4 7.5/4 10/5 10/5 7.5/4 10/5 690 - 7.5/4 10/5 10/5 10/5 10/5 25/13 25/13 10/5 25/13 75 100 60 84 0.5 Hydraulic-magnetic 75 100 60 84 0.5 Hydraulic-magnetic 75 100 60 84 0.5 Hydraulic-magnetic AC 690V 500V 440V 415V 400V 380V 240V 230V 400V 230V CE Marking CCC certificate Electrical Appliance and Material Safety Law E*2 Dimensions (mm) a a d c b c b d Mass (kg) Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & buttom connection Y Plug-in mounting P IEC 35mm wide rail mounting Internal accessories Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Insulation barrier Earth BL Handle locking cover L1 Flat terminal SS Block terminal SL BW50RAM 3 10, 12, 16, 24, 32, 40, 45 6 Conforming to standards 06 - - - : Approved : Available -: Not available : Factory-mounted accessory Note: *1Specify DC only when ordering circuit breakers for DC circuit. *2Electrical Appliance and Material Safety Law of Japan Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/19 Molded Case Circuit Breakers G-TWIN series Quick reference guide n G-TWIN Standard Series / Motor protection Ampere frame Type Pole Rated current Reference amb. temp. (40C) Rated impulse withstand voltage Isolation compliant Rated insulation voltage Ui (V) Rated breaking IEC 60947-2 capacity EN 60947-2 Icu/Ics (kA) JIS C 8201-2-1 GB14048.2 In(A) Uimp(kV) AC AC AC 690V 500V 440V 415V 400V 380V 240V 230V 400V 230V CE Marking CCC certificate Electrical Appliance and Material Safety Law E*2 Dimensions (mm) a a d c b c b d Mass (kg) Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & buttom connection Y Plug-in mounting P IEC 35mm wide rail mounting Internal accessories Page 06/63 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type QN Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Insulation barrier Earth BL Handle locking cover L1 Flat terminal SS Block terminal SL 63A BW63EAM 3 63 6 BW63SAM 3 63 6 100A BW100EAM 3 63, 75, 90 6 690 - 1.5/1 2.5/2 2.5/2 2.5/2 2.5/2 5/3 5/3 2.5/2 5/3 690 - 5/3 7.5/4 7.5/4 7.5/4 7.5/4 10/5 10/5 7.5/4 10/5 690 - 7.5/4 10/5 10/5 10/5 10/5 25/13 25/13 10/5 25/13 75 100 60 84 0.6 Hydraulic-magnetic 75 100 60 84 0.6 Hydraulic-magnetic 75 100 60 84 0.6 Hydraulic-magnetic Conforming to standards : Approved : Available -: Not available : Factory-mounted accessory Note: *1Specify DC only when ordering circuit breakers for DC circuit. *2Electrical Appliance and Material Safety Law of Japan 06/20 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Quick reference guide n G-TWIN Standard Series / Motor protection Ampere frame Type Pole Rated current Reference amb. temp. (40C) Rated impulse withstand voltage Isolation compliant Rated insulation voltage Ui (V) Rated breaking IEC 60947-2 capacity EN 60947-2 Icu/Ics (kA) JIS C 8201-2-1 GB14048.2 In(A) Uimp(kV) AC AC AC 690V 500V 440V 415V 400V 380V 240V 230V 400V 230V CE Marking CCC certificate Electrical Appliance and Material Safety Law E*2 a Dimensions (mm) a d c b c b d Mass (kg) Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, front connection E Flush mounting, top & buttom connection Y Plug-in mounting P IEC 35mm wide rail mounting Internal accessories Page 06/64 Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Page 06/66 Handle padlocking device Cap type Q1 Handle padlocking device Plate type Q2 Operating handle N-type N Operating handle V-type V Terminal cover Short BT S Terminal cover Long BT L Insulation barrier Interphase BP Handle locking cover L1 Flat terminal SS Block terminal SL 125A BW125JAM BW125RAM 3 3 16, 24, 32, 40, 45, 60, 75, 90 6 6 250A BW250EAM 3 125, 150, 175, 225 6 BW250JAM 3 BW250RAM 3 6 6 690 - 8/4 30/15 30/15 30/15 30/15 50/25 50/25 30/15 50/25 690 - 10/5 50/25 50/25 50/25 50/25 100/50 100/50 50/25 100/50 690 - 5/3 18/9 18/9 18/9 18/9 36/18 36/18 18/9 36/18 690 - 8/4 30/15 30/15 30/15 30/15 50/25 50/25 30/15 50/25 690 - 10/5 50/25 50/25 50/25 50/25 100/50 100/50 50/25 100/50 90 155 68 95 1.2 Thermal-magnetic 90 155 68 95 1.2 Thermal-magnetic - 105 165 68 95 1.6 Thermal-magnetic - 105 165 68 95 1.6 Thermal-magnetic - 105 165 68 95 1.6 Thermal-magnetic Conforming to standards 06 : Approved : Available -: Not available : Factory-mounted accessory Note: *1Specify DC only when ordering circuit breakers for DC circuit. 2 * Electrical Appliance and Material Safety Law of Japan Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/21 Molded Case Circuit Breakers G-TWIN series Mounting modifications n Mounting modifications * Standard series Standard type FUJI breakers are front mounting with front connections. The standard breaker can easily be modified to become front mounting rear connection type, flush mounting type and plug-in type. The additional parts such as insulation bases, barriers, covers and similar parts are added as required. Front mounting Front connection BASIC DESIGN Additional main parts Front mounting Rear connection (X type) Additional main parts Flush mounting Rear connection (E type) Additional main parts Plug-in mounting (P type) Bar stud terminal BW32 BW50 BW63 BW100 Bar stud terminal BW32 BW50 BW63 BW100 Bar stud terminal BW32 BW50 BW63 BW100 Bar stud terminal BW50HAG BW125 BW160 BW250 BW400 BW630 BW800 Bar stud terminal BW50HAG BW125 BW160 BW250 BW400 BW630 BW800 Round stud terminal BW50HAG BW125 Bar stud terminal Each stud can be turned by 90 06/22 Each stud can be turned by 90 Additional main parts Flush mounting Top and bottom connection (Y type) BW160 BW250 BW400 BW630 BW800 Decorative flush plate BW32 BW50 BW63 BW100 Each stud can be turned by 90 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Mounting modifications * Global series Front mounting Front connection BASIC DESIGN Screw Flat terminal Block terminal 06 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/23 Molded Case Circuit Breakers G-TWIN series Terminal connection n Terminal connection/Front mounting, front connection * 400AF to 800AF Front Front * 32AF to 100AF Flat terminal Self lifting screw Pan-head screw Breaker type Tightening torque (N*m) Size BW32 BW50 BW100* 2.3 to 2.8 M5 BW63 BW100 5.5 to 7.5 M8 Flat terminal Hexagonal head bolt 14 Breaker type Tightening torque (N*m) Size (mm) BW400 40 to 50 M12 35 BW630 BW800 40 to 50 M12 40 15 Type of connection/up to 250AF Front mounting front connection * Breaker of rated current : 50A Direct connection Front * 125AF to 250AF Flat terminal connection Flat terminals are required. Pan-head screw Hexagonal socket head bolt Breaker type Tightening torque (N*m) Size (mm) BW50HAG BW125 5.5 to 7.5 M8 16 BW160 BW250 8.0 to 13.0 M8 16 Flat terminal Flat bar studs/1-hole type Breaker type Pole Type of flat terminal BW32 BW50 2 3 BZ6S10C502 BZ6S10C503 BW63 BW100* 2 3 BZ6S10C1002 BZ6S10C1003 BW50HAG BW125 2 3 4 BW9SS0CA-2 BW9SS0CA-3 BW9SS0CA-4 BW160 BW250 2 3 4 BZ-S50B-2252 BZ-S50B-2253 BW9SS0GA-4 * BW100 breaker of rated current 50A: BZ6S10C502 or 503. 06/24 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Wire size and terminal n Wire size and crimp terminal The following is the size recommendations for crimp terminals. Ampere frame Breaker 32 BW32 50 63 Wire size(mm2) 1.04 2.63 | | 2.63 6.64 R2-5 R5.5-5 6.64 | 10.52 R8-5 10.52 | 16.78 R14-5 Crimp terminal R : JIS C2805 CB : JEM-1399 JST : Product of Japan Crimp Terminal Co., Ltd. 16.78 | 26.66 26.66 | 42.42 BW50AAG,EAG,SAG R2-5 R5.5-5 R8-5 R14-5 BW50HAG R2-8 R5.5-8 R8-8 R14-8 R22-8 BW63 R2-8 R5.5-8 R8-8 R14-8 JST22-S8 96.3 | 117.2 117.2 | 152.05 192.6 | 242.27 242.27 | 325 JST38-S8 CB60-8 100 BW100 R2-8 R5.5-8 R8-8 R14-8 JST22-S8 JST38-S8 125 160 250 400 BW125 BW160 BW250 BW400 R2-8 R5.5-8 R8-8 R14-8 R22-8 630 800 JST38-S8 CB60-8 R38-8 R60-8 CB100-8 R38-12 R60-12 R100-12 R150-12 R200-12 JST325-12 BW630 R100-12 R150-12 R200-12 JST325-12 BW800 R100-12 R150-12 R200-12 JST325-12 n Breaker R22-8 42.42 | 60.57 termination * Standard MCCB type Front connection Rear connection X Flush mounting E Y Plug-in mounting P BW32 BW50 06 Self-lifiting terminal BW63 BW100 BW50HAG BW125 Flat terminal BW160 BW250 Flat terminal BW400 BW630 BW800 Flat terminal 90 rotational stud Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 90 rotational stud 90 rotational stud 06/25 Molded Case Circuit Breakers G-TWIN series Wire size and terminal n Notes on wiring (global series) Notes on connecting wires (conductors) * Connect wires to the UL breaker according to NEC (National Electric Code) or CEC (Canadian Electrical Code) Part 1. * Use 75C copper wires for wiring. UL-certified or CSAcertified wires are recommended. * If a large current (for example, a short-circuit current) flows, it causes a huge electromagnetic force between wires. Therefore, be sure to secure the wires sufficiently. * Re-tighten terminal screws periodically. Code Blank Blank SB SF S3 S4 S5 S6 S7 S8 Terminal position Load Line Screw Screw Flat teminal Flat teminal Block terminal Block terminal Flat teminal Flat teminal Screw Flat terminal Flat teminal Screw Block terminal Screw Block terminal Screw Flat teminal Block terminal Block terminal Flat terminal Applicable breaker type BW50 BW100, 125, 250 - - BW400, 630, 800 - - - - - - - - - - - Block terminal connection * Choose from the stranded wires shown in Table. Wire size: AWG or MCM [mm2] 14 to 2 [2.1 to 33.6] 1 to 4/0 [42.4 to 107.2] 250 to 500 [127 to 250] No. of wires stranded 7 19 37 Values in [ ] are those converted from AWG or MCM sizes to mm2. * See the instruction manual that comes with the breaker for more details. Precautions * Two wires of different sizes cannot be connected to the same block terminal. * Be sure to use stranded wires according to Table "Number of wires stranded." * Multi-conductor wires cannot be connected. * Do not solder wires together. Wire size and crimp terminal * Crimp terminal connection MCCB Rated Applicable crimp terminal current 75C wire (A) J.S.T Mfg. Co., Ltd. Nichifu Co., Ltd. Connectable wire Tightening Type of size (AWG) torque screw head (N*m) and size Daido Solderless Terminal 75C wire (mm) Mfg. Co., Ltd. BW50RAGU 3 5 10 15 20 30 40 50 60 75 100 15 20 30 40 50 60 70 75 80 90 100 125 125 150 175 200 225 250 2-S5, 2-5 BW100EAGU BW125JAGU BW125RAGU BW250EAGU BW250JAGU BW250RAGU R2-5 R2-5M R2-5 14AWG 2.3-2.8 Cross/straight slotted pan-head screw M5 x 14 R5.5-5 R3.5-5S, R3.5-5L, 5.5-6N, 3.5-5, 5.5-S5, R5.5-5S, R5.5-5 5.5-5, 5.5-L5 R8-5 R8-5S, R8-5 8-S5, 8-5 12AWG 10AWG 8AWG R14-8 22-S8 38-S8 R2-8 5.5-S8, R5.5-8 8-8NS, R8-8 R14-8S, R14-8 R22-8S, R22-8 R38-8S R2-8 R3.5-8, R5.5-8 R5.5-8 R8-8 R14-S8, R14-8 R22-S8, 22-8 38-S8 2-8, 2-B8 3.5-8, 5.5-8 5.5-8 8-8 6AWG 4AWG 3AWG 14AWG 12AWG 10AWG 8AWG 14-8NS, 14-S8, R14-8 22-S8, R22-8, CB22-S8 R14-8S, R14-8 14-S8, 14-8 R22-8S, R22-8, CB22-8S 22-S8, 22-8, CB22-8 6AWG 4AWG 38-S8 R38-8S 3AWG 38-S8, R38-8 60-S8, R60-8 70-8 CB80-S8 CB100-S8 CB150-S8 R38-8S, R38-8 38-S8, 38-8 R60-8, CB60-8, CB60-8S 60-8, CB60-8 R70-8 70-8 CB80-8 CB100-8 CB150-8 CB150-8 38-S8 1AWG 1AWG 1/0AWG 2/0AWG 3/0AWG 4/0AWG 250MCM 5.5-7.5 Cross/straight slotted pan-head screw M8 x 15 5.8 (5.3-6.4) Cross/straight slotted pan-head screw 10.5 (8-13) Hexagon socket head bolt M8 x 16 M8 x 16 Notes: * AWG/MCM is the UL approved wire unit. * The allowable temperature of wire is 75C. (UL CSA approved) * Be sure to use UL-certified or CSA-certified crimp tools commercially available. 06/26 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Wire size and terminal * Flat terminal connection MCCB Rated Applicable crimp terminal current 75C wire (A) J.S.T Mfg. Co., Ltd. Nichifu Co., Ltd. BW50RAGU 3 5 10 15 20 30 40 50 60 75 100 15 20 30 40 50 60 70 75 80 90 100 125 125 150 175 200 225 250 250 300 350 400 BW100EAGU BW125JAGU BW125RAGU BW250EAGU BW250JAGU BW250RAGU BW400EAGU BW400SAGU BW400RAGU BW400HAGU BW630RAGU 500 BW630HAGU 600 630 BW800RAGU 700 BW800HAGU R2-5 R2-5M R2-5 Connectable Tightening torque wire size (AWG) (N*m) Daido Solderless 75C wire Wire MCCB Terminal Mfg. Co., Ltd. side side 2-S5, 2-5 14AWG 3.5 to 4.5 2.3 to 2.8 R3.5-5S, R3.5-5L, 5.5-6N. 3.5-5, 5.5-S5 R5.5-5S, R5.5-5 5.5-5, 5.5-L5 R8-5 R8-5S, R8-5 8-S5, 8-5 12AWG 10AWG 8AWG R14-8 22-S8 38-S8 R2-8 5.5-S8, R5.5-8 R14-8S, R14-8 R22-8S, R22-8 R38-8S R2-8 R3.5-8, R5.5-8 R5.5-8 R8-8 R14-S8, R14-8 R22-S8, 22-8 38-S8 2-8, 2-B8 3.5-8, 5.5-8 5.5-8 8-8 6AWG 4AWG 3AWG 14AWG 12AWG 10AWG 8AWG 14-8NS, 14-S8, R14-8 R14-8S, R14-8 14-S8, 14-8 22-S8, R22-8, CB22-S8 R22-8S, R22-8, CB22-8S 22-S8, 22-8, CB22-8 6AWG 4AWG 38-S8 3AWG 38-S8, R38-8 60-S8, R60-8 70-8 CB80-S8 CB100-S8 CB150-S8 150-12 180-12 325-12 325-12 R80-12 R150-12 180-12 325-12 325-12 R38-8S Hexagon socket head bolt M5 x 16 R5.5-5 8-8NS, R8-8 Type of screw head and size (mm) 38-S8 R38-8S, R38-8 38-S8, 38-8 R60-8, CB60-8, CB60-8S 60-8, CB60-8 R70-8 70-8 CB80-8 CB100-8 CB150-8 CB150-8 R150-12 R180-12 R325-12N R325-12N R80-12 R150-12 R180-12 R325-12N R325-12 R325-12 1AWG 1AWG 1/0AWG 2/0AWG 3/0AWG 4/0AWG 250MCM 250MCM 350MCM 500MCM 500MCM 3/0AWG(x2) 250MCM(x2) 350MCM(x2) 500MCM(x2) 500MCM(x2) 8 to 10 5.5 to 7.5 9 (8 to 10) Cross/straight 5.8 (5.3 to 6.4) slotted pan-head Hexagon socket head bolt M8 x 22 screw M8 x 16 06 9 (8 to 10) 10.5 (8 to 13) 45 (40 to 50) Hexagon head 43.5 (39.2 to 48) bolt M12 x 35 Hexagon socket head bolt M8 x 16 Hexagon head 47.04 47.04 (42.4 to 51.7) (42.4 to 51.7) bolt M12 x 40 Hexagon head 47.04 47.04 (42.4 to 51.7) (42.4 to 51.7) bolt M12 x 40 Notes: * AWG/MCM is the UL approved wire unit. * The allowable temperature of wire is 75C. (UL CSA approved) Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/27 Molded Case Circuit Breakers G-TWIN series Wire size and terminal * Block terminal connection MCCB Rated current (A) Connectable wire size (AWG) BW100EAGU 60 70 75 80 90 100 15 20 30 40 50 60 70 75 80 90 100 125 125 150 175 200 225 250 250 300 350 400 6AWG 4AWG 500 600 700 800 250MCM(x2) 350MCM(x2) 500MCM(x2) 300MCM(x3) BW125JAGU BW125RAGU BW250EAGU BW250JAGU BW250RAGU BW400EAGU BW400SAGU BW400RAGU BW400HAGU BW630RAGU BW630HAGU BW800RAGU BW800HAGU Tightening torque (N*m) Type of screw head and size (mm) 5.8 Slotted set screw (5.5 to 6.5) Figure 3AWG 14AWG 12AWG 10AWG 8AWG 5.8 (5.8 to 6.4) Slotted set screw 23 (23 to 25.3) Hexagon socket head setscrew: 8 mm (5/16 inch) 6AWG 4AWG 3AWG 1AWG 1AWG 1/0AWG 2/0AWG 3/0AWG 4/0AWG 250MCM 250MCM 350MCM 500MCM 3/0AWG(x2) Screw head size 43.5 (43.5 to 48) Hexagon socket head setscrew: 9.53 mm (3/8 inch) 31.9 (31.9 to 35.1) Hexagon socket head setscrew: 8 mm (5/16 inch) Hexagon socket head setscrew: 8 mm (5/16 inch) Hexagon socket head setscrew: 8 mm (5/16 inch) 31.1 (31.1 to 34.2) 31.1 (31.1 to 34.2) Notes: * AWG/MCM is the UL approved wire unit. * The allowable temperature of wire is 75C. (UL CSA approved) 06/28 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Type number/Line protection n Type l number, Standard series (Line protection) AAG series, 2-pole IEC/EN/GB/JIS conformed l EAG series, 2-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection Breaker Rated current Type ampere (A) frame : Available mounting and connection 32 Blank, X, E, Y, P 50 Blank, X, E, Y, P 50 3 5 10 15 20 30 32 5 10 15 20 30 32 40 50 BW32AAG-2P003 BW32AAG-2P005 BW32AAG-2P010 BW32AAG-2P015 BW32AAG-2P020 BW32AAG-2P030 BW32AAG-2P032 BW50AAG-2P005 BW50AAG-2P010 BW50AAG-2P015 BW50AAG-2P020 BW50AAG-2P030 BW50AAG-2P032 BW50AAG-2P040 BW50AAG-2P050 Blank, X, E, Y, P 63 100 160 Mounting Connection Front Front Flush Flush Plug-in Front Rear Rear Top and buttom Blank X E Y P 250 400 l BW50EAG-2P005 BW50EAG-2P010 BW50EAG-2P015 BW50EAG-2P020 BW50EAG-2P030 BW50EAG-2P032 BW50EAG-2P040 BW50EAG-2P050 BW63EAG-2P060 BW63EAG-2P063 BW100EAG-2P050 BW100EAG-2P060 BW100EAG-2P063 BW100EAG-2P075 BW100EAG-2P100 BW160EAG-2P125 BW160EAG-2P150 BW160EAG-2P160 BW250EAG-2P175 BW250EAG-2P200 BW250EAG-2P225 BW250EAG-2P250 BW400EAG-2P250 BW400EAG-2P300 BW400EAG-2P350 BW400EAG-2P400 Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, P Blank, X, E, P Blank, X, E, P JAG series, 2-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection 125 Blank, X, E, P 160 250 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 5 10 15 20 30 32 40 50 60 63 50 60 63 75 100 125 150 160 175 200 225 250 250 300 350 400 15 20 30 40 50 60 75 100 125 125 150 160 175 200 225 250 BW125JAG-2P015 BW125JAG-2P020 BW125JAG-2P030 BW125JAG-2P040 BW125JAG-2P050 BW125JAG-2P060 BW125JAG-2P075 BW125JAG-2P100 BW125JAG-2P125 BW160JAG-2P125 BW160JAG-2P150 BW160JAG-2P160 BW250JAG-2P175 BW250JAG-2P200 BW250JAG-2P225 BW250JAG-2P250 Blank, X, E, P Blank, X, E, P 06/29 06 Molded Case Circuit Breakers G-TWIN series Type number/Line protection l SAG series, 2-pole IEC/EN/GB/JIS conformed l RAG series, 2-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection* Breaker Rated current Type ampere (A) frame : Available mounting and connection* 32 Blank, X, E, Y, P 50 Blank, X, E, Y, P Blank, X, E, Y, P 63 50 63 125 160 250 400 l 3 5 10 15 20 30 32 5 10 15 20 30 32 40 50 60 63 15 20 30 40 50 60 75 100 125 125 150 160 175 200 225 250 250 300 350 400 BW32SAG-2P003 BW32SAG-2P005 BW32SAG-2P010 BW32SAG-2P015 BW32SAG-2P020 BW32SAG-2P030 BW32SAG-2P032 BW50SAG-2P005 BW50SAG-2P010 BW50SAG-2P015 BW50SAG-2P020 BW50SAG-2P030 BW50SAG-2P032 BW50SAG-2P040 BW50SAG-2P050 BW63SAG-2P060 BW63SAG-2P063 BW125SAG-2P015 BW125SAG-2P020 BW125SAG-2P030 BW125SAG-2P040 BW125SAG-2P050 BW125SAG-2P060 BW125SAG-2P075 BW125SAG-2P100 BW125SAG-2P125 BW160SAG-2P125 BW160SAG-2P150 BW160SAG-2P160 BW250SAG-2P175 BW250SAG-2P200 BW250SAG-2P225 BW250SAG-2P250 BW400SAG-2P250 BW400SAG-2P300 BW400SAG-2P350 BW400SAG-2P400 125 Blank, X, E, Y, P Blank, X, E, P 160 250 400 Blank, X, E, P l Blank, X, E, P Breaker Rated current Type ampere (A) frame : Available mounting and connection* 400 Blank, X, E, P * See page 06/29. 06/30 BW400HAG-2P250 BW400HAG-2P300 BW400HAG-2P350 BW400HAG-2P400 BW50RAG-2P010 BW50RAG-2P015 BW50RAG-2P020 BW50RAG-2P030 BW50RAG-2P032 BW50RAG-2P040 BW50RAG-2P050 BW63RAG-2P060 BW63RAG-2P063 BW125RAG-2P015 BW125RAG-2P020 BW125RAG-2P030 BW125RAG-2P040 BW125RAG-2P050 BW125RAG-2P060 BW125RAG-2P075 BW125RAG-2P100 BW125RAG-2P125 BW160RAG-2P125 BW160RAG-2P150 BW160RAG-2P160 BW250RAG-2P175 BW250RAG-2P200 BW250RAG-2P225 BW250RAG-2P250 BW400RAG-2P250 BW400RAG-2P300 BW400RAG-2P350 BW400RAG-2P400 Blank, X, E, Y, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P HAG series, 2-pole IEC/EN/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection* 50 Blank, X, E, P HAG series, 2-pole IEC/EN/GB/JIS conformed 250 300 350 400 10 15 20 30 32 40 50 60 63 15 20 30 40 50 60 75 100 125 125 150 160 175 200 225 250 250 300 350 400 125 250 15 20 30 40 50 15 20 30 40 50 60 75 100 125 125 150 160 175 200 225 250 BW50HAG-2P015 BW50HAG-2P020 BW50HAG-2P030 BW50HAG-2P040 BW50HAG-2P050 BW125HAG-2P015 BW125HAG-2P020 BW125HAG-2P030 BW125HAG-2P040 BW125HAG-2P050 BW125HAG-2P060 BW125HAG-2P075 BW125HAG-2P100 BW125HAG-2P125 BW250HAG-2P125 BW250HAG-2P150 BW250HAG-2P160 BW250HAG-2P175 BW250HAG-2P200 BW250HAG-2P225 BW250HAG-2P250 Blank, X, E, P Blank, X, E, P Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Type number/Line protection l AAG series, 3-pole IEC/EN/GB/JIS conformed l EAG series, 3-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection* Breaker Rated current Type ampere (A) frame : Available mounting and connection* 32 Blank, X, E, Y, P 50 Blank, X, E, Y, P 50 100 3 5 10 15 20 30 32 5 10 15 20 30 32 40 50 60 63 75 100 BW32AAG-3P003 BW32AAG-3P005 BW32AAG-3P010 BW32AAG-3P015 BW32AAG-3P020 BW32AAG-3P030 BW32AAG-3P032 BW50AAG-3P005 BW50AAG-3P010 BW50AAG-3P015 BW50AAG-3P020 BW50AAG-3P030 BW50AAG-3P032 BW50AAG-3P040 BW50AAG-3P050 BW100AAG-3P060 BW100AAG-3P063 BW100AAG-3P075 BW100AAG-3P100 Blank, X, E, Y, P 63 100 Blank, X, E, Y, P 160 250 400 630 800 l 5 10 15 20 30 32 40 50 60 63 50 60 63 75 100 125 150 160 175 200 225 250 250 300 350 400 500 600 630 700 800 BW50EAG-3P005 BW50EAG-3P010 BW50EAG-3P015 BW50EAG-3P020 BW50EAG-3P030 BW50EAG-3P032 BW50EAG-3P040 BW50EAG-3P050 BW63EAG-3P060 BW63EAG-3P063 BW100EAG-3P050 BW100EAG-3P060 BW100EAG-3P063 BW100EAG-3P075 BW100EAG-3P100 BW160EAG-3P125 BW160EAG-3P150 BW160EAG-3P160 BW250EAG-3P175 BW250EAG-3P200 BW250EAG-3P225 BW250EAG-3P250 BW400EAG-3P250 BW400EAG-3P300 BW400EAG-3P350 BW400EAG-3P400 BW630EAG-3P500 BW630EAG-3P600 BW630EAG-3P630 BW800EAG-3P700 BW800EAG-3P800 Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P JAG series, 3-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection* 125 Blank, X, E, P 160 250 15 20 30 40 50 60 75 100 125 125 150 160 175 200 225 250 BW125JAG-3P015 BW125JAG-3P020 BW125JAG-3P030 BW125JAG-3P040 BW125JAG-3P050 BW125JAG-3P060 BW125JAG-3P075 BW125JAG-3P100 BW125JAG-3P125 BW160JAG-3P125 BW160JAG-3P150 BW160JAG-3P160 BW250JAG-3P175 BW250JAG-3P200 BW250JAG-3P225 BW250JAG-3P250 Blank, X, E, P Blank, X, E, P * See page 06/29. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/31 06 Molded Case Circuit Breakers G-TWIN series Type number/Line protection l SAG series, 3-pole IEC/EN/GB/JIS conformed l RAG series, 3-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection* Breaker Rated current Type ampere (A) frame : Available mounting and connection* 32 Blank, X, E, Y, P 50 Blank, X, E, Y, P Blank, X, E, Y, P 63 50 63 125 160 250 400 3 5 10 15 20 30 32 5 10 15 20 30 32 40 50 60 63 15 20 30 40 50 60 75 100 125 125 150 160 175 200 225 250 250 300 350 400 BW32SAG-3P003 BW32SAG-3P005 BW32SAG-3P010 BW32SAG-3P015 BW32SAG-3P020 BW32SAG-3P030 BW32SAG-3P032 BW50SAG-3P005 BW50SAG-3P010 BW50SAG-3P015 BW50SAG-3P020 BW50SAG-3P030 BW50SAG-3P032 BW50SAG-3P040 BW50SAG-3P050 BW63SAG-3P060 BW63SAG-3P063 BW125SAG-3P015 BW125SAG-3P020 BW125SAG-3P030 BW125SAG-3P040 BW125SAG-3P050 BW125SAG-3P060 BW125SAG-3P075 BW125SAG-3P100 BW125SAG-3P125 BW160SAG-3P125 BW160SAG-3P150 BW160SAG-3P160 BW250SAG-3P175 BW250SAG-3P200 BW250SAG-3P225 BW250SAG-3P250 BW400SAG-3P250 BW400SAG-3P300 BW400SAG-3P350 BW400SAG-3P400 125 Blank, X, E, Y, P Blank, X, E, P 160 250 400 Blank, X, E, P Blank, X, E, P 630 800 Blank, X, E, P l 10 15 20 30 32 40 50 60 63 15 20 30 40 50 60 75 100 125 125 150 160 175 200 225 250 250 300 350 400 500 600 630 700 800 BW50RAG-3P010 BW50RAG-3P015 BW50RAG-3P020 BW50RAG-3P030 BW50RAG-3P032 BW50RAG-3P040 BW50RAG-3P050 BW63RAG-3P060 BW63RAG-3P063 BW125RAG-3P015 BW125RAG-3P020 BW125RAG-3P030 BW125RAG-3P040 BW125RAG-3P050 BW125RAG-3P060 BW125RAG-3P075 BW125RAG-3P100 BW125RAG-3P125 BW160RAG-3P125 BW160RAG-3P150 BW160RAG-3P160 BW250RAG-3P175 BW250RAG-3P200 BW250RAG-3P225 BW250RAG-3P250 BW400RAG-3P250 BW400RAG-3P300 BW400RAG-3P350 BW400RAG-3P400 BW630RAG-3P500 BW630RAG-3P600 BW630RAG-3P630 BW800RAG-3P700 BW800RAG-3P800 Blank, X, E, Y, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P HAG series, 3-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection* 400 Blank, X, E, P 630 800 250 300 350 400 500 600 630 700 800 BW400HAG-3P250 BW400HAG-3P300 BW400HAG-3P350 BW400HAG-3P400 BW630HAG-3P500 BW630HAG-3P600 BW630HAG-3P630 BW800HAG-3P700 BW800HAG-3P800 Blank, X, E, P Blank, X, E, P * See page 06/29. 06/32 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Type number/Line protection l JAG series, 4-pole IEC/EN/GB/JIS conformed l RAG series, 4-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection* Breaker Rated current Type ampere (A) frame : Available mounting and connection* 125 Blank, X, E 125 Blank, X, E Blank, X, E 160 Blank, X, E 250 160 250 15 20 30 40 50 60 75 100 125 125 150 160 175 200 225 250 BW125JAG-4P015 BW125JAG-4P020 BW125JAG-4P030 BW125JAG-4P040 BW125JAG-4P050 BW125JAG-4P060 BW125JAG-4P075 BW125JAG-4P100 BW125JAG-4P125 BW160JAG-4P125 BW160JAG-4P150 BW160JAG-4P160 BW250JAG-4P175 BW250JAG-4P200 BW250JAG-4P225 BW250JAG-4P250 400 l SAG series, 4-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection* 125 Blank, X, E 160 250 15 20 30 40 50 60 75 100 125 125 150 160 175 200 225 250 BW125SAG-3P015 BW125SAG-3P020 BW125SAG-3P030 BW125SAG-3P040 BW125SAG-3P050 BW125SAG-3P060 BW125SAG-3P075 BW125SAG-3P100 BW125SAG-3P125 BW160SAG-3P125 BW160SAG-3P150 BW160SAG-3P160 BW250SAG-3P175 BW250SAG-3P200 BW250SAG-3P225 BW250SAG-3P250 630 800 l Blank, X, E 15 20 30 40 50 60 75 100 125 125 150 160 175 200 225 250 250 300 350 400 500 600 630 700 800 BW125RAG-4P015 BW125RAG-4P020 BW125RAG-4P030 BW125RAG-4P040 BW125RAG-4P050 BW125RAG-4P060 BW125RAG-4P075 BW125RAG-4P100 BW125RAG-4P125 BW160RAG-4P125 BW160RAG-4P150 BW160RAG-4P160 BW250RAG-4P175 BW250RAG-4P200 BW250RAG-4P225 BW250RAG-4P250 BW400RAG-4P250 BW400RAG-4P300 BW400RAG-4P350 BW400RAG-4P400 BW630RAG-4P500 BW630RAG-4P600 BW630RAG-4P630 BW800RAG-4P700 BW800RAG-4P800 Blank, X, E Blank, X, E Blank, X, E Blank, X, E 06 Blank, X, E HAG series, 4-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection* 400 Blank, X, E Blank, X, E 630 800 250 300 350 400 500 600 630 700 800 BW400HAG-4P250 BW400HAG-4P300 BW400HAG-4P350 BW400HAG-4P400 BW630HAG-4P500 BW630HAG-4P600 BW630HAG-4P630 BW800HAG-4P700 BW800HAG-4P800 Blank, X, E Blank, X, E * See page 06/29. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/33 Molded Case Circuit Breakers G-TWIN series Type number/Line protection n Type l number, Global series (Line protection) EAGU series, 2-pole UL489 Listed l SAGU series, 2-pole UL489 Listed Breaker Rated current Type ampere (A) frame : Available mounting and connection Breaker Rated current Type ampere (A) frame : Available mounting and connection 100 Blank, SB, SF, S3 S4, S5, S6, S7, S8 400 Blank, SB, S7, S8 250 400 l 60 63 70 75 80 90 100 125 150 160 175 200 225 250 250 300 350 400 BW100EAGU-2P060 BW100EAGU-2P063 BW100EAGU-2P070 BW100EAGU-2P075 BW100EAGU-2P080 BW100EAGU-2P090 BW100EAGU-2P100 BW250EAGU-2P125 BW250EAGU-2P150 BW250EAGU-2P160 BW250EAGU-2P175 BW250EAGU-2P200 BW250EAGU-2P225 BW250EAGU-2P250 BW400EAGU-2P250 BW400EAGU-2P300 BW400EAGU-2P350 BW400EAGU-2P400 l Blank, SB, SF, S3 S4, S5, S6, S7, S8 : Available mounting and connection 125 Blank, SB, SF, S3 S4, S5, S6, S7, S8 250 15 20 30 40 50 60 70 75 80 90 100 125 125 150 160 175 200 225 250 BW125JAGU-2P015 BW125JAGU-2P020 BW125JAGU-2P030 BW125JAGU-2P040 BW125JAGU-2P050 BW125JAGU-2P060 BW125JAGU-2P070 BW125JAGU-2P075 BW125JAGU-2P080 BW125JAGU-2P090 BW125JAGU-2P100 BW125JAGU-2P125 BW250JAGU-2P125 BW250JAGU-2P150 BW250JAGU-2P160 BW250JAGU-2P175 BW250JAGU-2P200 BW250JAGU-2P225 BW250JAGU-2P250 50 Blank, SF, S3, S4 Blank, SB, SF, S3 S4, S5, S6, S7, S8 400 l : 06/34 : Available mounting and connection 250 Terminal combination Terminal position Code Line Blank Screw Blank Flat terminal SB Block terminal SF Flat terminal S3 Screw S4 Flat terminal S5 Screw S6 Block terminal S7 Flat terminal S8 Block terminal Breaker Rated current Type ampere (A) frame 125 Breaker Rated current Type ampere (A) frame Load Screw Flat terminal Block terminal Flat terminal Flat terminal Screw Block terminal Screw Block terminal Flat terminal Breaker type BW50 BW100,125,250 BW400,630,800 - - - - - - - - - - - - - BW400SAGU-2P250 BW400SAGU-2P300 BW400SAGU-2P350 BW400SAGU-2P400 RAGU series, 2-pole UL489 Listed Blank, SB, S7, S8 JAGU series, 2-pole UL489 Listed 250 300 350 400 3 5 10 15 20 30 32 40 50 15 20 30 40 50 60 70 75 80 90 100 125 125 150 160 175 200 225 250 250 300 350 400 BW50RAGU-2P003 BW50RAGU-2P005 BW50RAGU-2P010 BW50RAGU-2P015 BW50RAGU-2P020 BW50RAGU-2P030 BW50RAGU-2P032 BW50RAGU-2P040 BW50RAGU-2P050 BW125RAGU-2P015 BW125RAGU-2P020 BW125RAGU-2P030 BW125RAGU-2P040 BW125RAGU-2P050 BW125RAGU-2P060 BW125RAGU-2P070 BW125RAGU-2P075 BW125RAGU-2P080 BW125RAGU-2P090 BW125RAGU-2P100 BW125RAGU-2P125 BW250RAGU-2P125 BW250RAGU-2P150 BW250RAGU-2P160 BW250RAGU-2P175 BW250RAGU-2P200 BW250RAGU-2P225 BW250RAGU-2P250 BW400RAGU-2P250 BW400RAGU-2P300 BW400RAGU-2P350 BW400RAGU-2P400 Blank, SB, SF, S3 S4, S5, S6, S7, S8 Blank, SB, SF, S3 S4, S5, S6, S7, S8 Blank, SB, S7, S8 HAGU series, 2-pole UL489 Listed Breaker Rated current Type ampere (A) frame : Available mounting and connection 400 Blank, SB, S7, S8 250 300 350 400 BW400HAGU-2P250 BW400HAGU-2P300 BW400HAGU-2P350 BW400HAGU-2P400 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Type number/Line protection l EAGU series, 3-pole UL489 Listed l RAGU series, 3-pole UL489 Listed Breaker Rated current Type ampere (A) frame : Available mounting and connection* Breaker Rated current Type ampere (A) frame : Available mounting and connection* 100 Blank, SB, SF, S3 S4, S5, S6, S7, S8 50 Blank, SB, S3, S4 250 400 l 60 63 70 75 80 90 100 125 150 160 175 200 225 250 250 300 350 400 BW100EAGU-3P060 BW100EAGU-3P063 BW100EAGU-3P070 BW100EAGU-3P075 BW100EAGU-3P080 BW100EAGU-3P090 BW100EAGU-3P100 BW250EAGU-3P125 BW250EAGU-3P150 BW250EAGU-3P160 BW250EAGU-3P175 BW250EAGU-3P200 BW250EAGU-3P225 BW250EAGU-3P250 BW400EAGU-3P250 BW400EAGU-3P300 BW400EAGU-3P350 BW400EAGU-3P400 Blank, SB, SF, S3 S4, S5, S6, S7, S8 125 Blank, SB, S7, S8 JAGU series, 3-pole UL489 Listed Breaker Rated current Type ampere (A) frame : Available mounting and connection* 125 Blank, SB, SF, S3 S4, S5, S6, S7, S8 250 l 15 20 30 40 50 60 70 75 80 90 100 125 125 150 160 175 200 225 250 BW125JAGU-3P015 BW125JAGU-3P020 BW125JAGU-3P030 BW125JAGU-3P040 BW125JAGU-3P050 BW125JAGU-3P060 BW125JAGU-3P070 BW125JAGU-3P075 BW125JAGU-3P080 BW125JAGU-3P090 BW125JAGU-3P100 BW125JAGU-3P125 BW250JAGU-3P125 BW250JAGU-3P150 BW250JAGU-3P160 BW250JAGU-3P175 BW250JAGU-3P200 BW250JAGU-3P225 BW250JAGU-3P250 250 400 630 800 Blank, SB, SF, S3 S4, S5, S6, S7, S8 l : Available mounting and connection* 400 Blank, SB, S7, S8 250 300 350 400 BW400SAGU-3P250 BW400SAGU-3P300 BW400SAGU-3P350 BW400SAGU-3P400 BW50RAGU-3P003 BW50RAGU-3P005 BW50RAGU-3P010 BW50RAGU-3P015 BW50RAGU-3P020 BW50RAGU-3P030 BW50RAGU-3P032 BW50RAGU-3P040 BW50RAGU-3P050 BW125RAGU-3P015 BW125RAGU-3P020 BW125RAGU-3P030 BW125RAGU-3P040 BW125RAGU-3P050 BW125RAGU-3P060 BW125RAGU-3P070 BW125RAGU-3P075 BW125RAGU-3P080 BW125RAGU-3P090 BW125RAGU-3P100 BW125RAGU-3P125 BW250RAGU-3P125 BW250RAGU-3P150 BW250RAGU-3P160 BW250RAGU-3P175 BW250RAGU-3P200 BW250RAGU-3P225 BW250RAGU-3P250 BW400RAGU-3P250 BW400RAGU-3P300 BW400RAGU-3P350 BW400RAGU-3P400 BW630RAGU-3P500 BW630RAGU-3P600 BW630RAGU-3P630 BW800RAGU-3P700 BW800RAGU-3P800 Blank, SB, SF, S3 S4, S5, S6, S7, S8 Blank, SB, SF, S3 S4, S5, S6, S7, S8 Blank, SB, S7, S8 Blank, SB, S7, S8 Blank, SB, S7, S8 HAGU series, 3-pole UL489 Listed Breaker Rated current Type ampere (A) frame : Available mounting and connection* 400 Blank, SB, S7, S8 SAGU series, 3-pole UL489 Listed Breaker Rated current Type ampere (A) frame 3 5 10 15 20 30 32 40 50 15 20 30 40 50 60 70 75 80 90 100 125 125 150 160 175 200 225 250 250 300 350 400 500 600 630 700 800 630 800 250 300 350 400 500 600 630 700 800 BW400HAGU-3P250 BW400HAGU-3P300 BW400HAGU-3P350 BW400HAGU-3P400 BW630HAGU-3P500 BW630HAGU-3P600 BW630HAGU-3P630 BW800HAGU-3P700 BW800HAGU-3P800 Blank, SB, S7, S8 Blank, SB, S7, S8 * See page 06/34. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/35 06 Molded Case Circuit Breakers G-TWIN series Type number/Motor protection n Type l number, Standard series (Motor protection) SAM series, 2-pole IEC/EN/GB/JIS conformed l AAM series, 3-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection Breaker Rated current Type ampere (A) frame : Available mounting and connection 32 Blank, X, E, Y, P 32 Blank, X, E, Y, P 0.7 1.4 2.6 4 8 10 16 24 32 BW32SAM-2P0P7 BW32SAM-2P1P4 BW32SAM-2P2P6 BW32SAM-2P004 BW32SAM-2P008 BW32SAM-2P010 BW32SAM-2P016 BW32SAM-2P024 BW32SAM-2P032 l Mounting Connection Front Front Flush Flush Plug-in Front Rear Rear Top and buttom Blank X E Y P 1.4 2.6 4 8 10 16 24 32 EAM series, 3-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection 50 Blank, X, E, Y, P 63 100 250 l 24 32 40 45 63 63 75 90 125 150 175 225 BW50EAM-3P024 BW50EAM-3P032 BW50EAM-3P040 BW50EAM-3P045 BW63EAM-3P063 BW100EAM-3P063 BW100EAM-3P075 BW100EAM-3P090 BW250EAM-3P125 BW250EAM-3P150 BW250EAM-3P175 BW250EAM-3P225 Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, P JAM series, 3-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection 125 Blank, X, E, P 250 06/36 BW32AAM-3P1P4 BW32AAM-3P2P6 BW32AAM-3P004 BW32AAM-3P008 BW32AAM-3P010 BW32AAM-3P016 BW32AAM-3P024 BW32AAM-3P032 16 24 32 40 60 75 90 125 150 175 225 BW125JAM-3P016 BW125JAM-3P024 BW125JAM-3P032 BW125JAM-3P040 BW125JAM-3P060 BW125JAM-3P075 BW125JAM-3P090 BW250JAM-3P125 BW250JAM-3P150 BW250JAM-3P175 BW250JAM-3P225 Blank, X, E, P Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Type number/Motor protection l SAM series, 3-pole IEC/EN/GB/JIS conformed l RAM series, 3-pole IEC/EN/GB/JIS conformed Breaker Rated current Type ampere (A) frame : Available mounting and connection* Breaker Rated current Type ampere (A) frame : Available mounting and connection* 32 Blank, X, E, Y, P 50 Blank, X, E, Y, P 50 63 0.7 1.4 2.6 4 8 10 16 24 32 0.7 1.4 2 2.6 4 5 8 10 12 16 24 32 40 45 63 BW32SAM-3P0P7 BW32SAM-3P1P4 BW32SAM-3P2P6 BW32SAM-3P004 BW32SAM-3P008 BW32SAM-3P010 BW32SAM-3P016 BW32SAM-3P024 BW32SAM-3P032 BW50SAM-3P0P7 BW50SAM-3P1P4 BW50SAM-3P002 BW50SAM-3P2P6 BW50SAM-3P004 BW50SAM-3P005 BW50SAM-3P008 BW50SAM-3P010 BW50SAM-3P012 BW50SAM-3P016 BW50SAM-3P024 BW50SAM-3P032 BW50SAM-3P040 BW50SAM-3P045 BW63SAM-3P063 Blank, X, E, Y, P 125 250 Blank, X, E, Y, P 0.7 1.4 2 2.6 4 5 8 10 12 16 24 32 40 45 16 24 32 40 60 75 90 125 150 175 225 BW50RAM-3P0P7 BW50RAM-3P1P4 BW50RAM-3P002 BW50RAM-3P2P6 BW50RAM-3P004 BW50RAM-3P005 BW50RAM-3P008 BW50RAM-3P010 BW50RAM-3P012 BW50RAM-3P016 BW50RAM-3P024 BW50RAM-3P032 BW50RAM-3P040 BW50RAM-3P045 BW125RAM-3P016 BW125RAM-3P024 BW125RAM-3P032 BW125RAM-3P040 BW125RAM-3P060 BW125RAM-3P075 BW125RAM-3P090 BW250RAM-3P125 BW250RAM-3P150 BW250RAM-3P175 BW250RAM-3P225 Blank, X, E, P Blank, X, E, P * See page 06/36. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/37 06 Molded Case Circuit Breakers G-TWIN series Arc space n Arc space, mm D2 D3 B A F D1 C 06/38 Vertical distance Side plate distance C B 230V 230V 440V 440V 10 10 - - 15 30 20 30 10 10 - - 15 30 25 30 15 40 25 40 15 50 25 50 20 80 50 80 15 30 25 30 15 40 25 40 15 50 25 50 15 20 - - 15 50 25 50 20 50 25 50 20 60 25 60 20 60 25 60 20 80 50 80 15 50 50 50 20 60 50 60 20 80 50 80 20 80 50 80 15 50 50 50 20 60 50 60 20 80 50 80 20 80 50 80 60 80 60 80 20 80 50 100 20 80 50 100 40 80 80 100 40 80 80 100 40 80 80 100 40 80 80 100 40 100 80 120 40 80 80 100 40 80 80 100 40 100 80 120 Front plate distance Painted No painted F F 230V 440V 230V 440V 0 0 - - 0 0 0 0 0 0 - - 0 0 0 0 0 0 0 0 0 5 0 10 0 5 5 10 0 0 0 0 0 0 0 0 0 5 0 10 0 0 - - 0 5 0 10 0 5 0 10 0 5 5 10 0 5 5 10 0 5 5 10 0 5 0 10 0 5 0 10 0 10 5 10 0 10 5 10 0 5 0 10 0 5 0 10 0 10 5 10 0 10 5 10 0 10 5 10 0 5 0 10 0 5 0 10 0 10 5 20 0 10 5 20 0 5 0 10 0 10 5 20 0 10 5 20 0 5 0 10 0 10 5 20 0 20 5 20 Taping Crimp type Bus-bar terminal lug D1 D2 10 30 10 30 30 50 80 30 30 50 50 50 50 50 50 80 80 80 80 80 80 80 80 80 80 100 100 100 100 100 100 120 100 100 120 Exposed live part dimension +20 Ceiling distance Frame MCCB basic type size A 440V 230V - 32A BW32A 10 10 BW32S 10 - BW50A 50A 10 10 BW50E 10 30 BW50S 10 50 BW50R 25 60 BW50H 60 10 BW63E 63A 10 30 BW63S 10 50 BW63R 25 100A BW100A - 10 BW100E 50 25 125A BW125J 40 40 BW125S 40 40 BW125R 40 40 BW125H 60 60 160A BW160E 40 40 BW160J 40 40 BW160S 40 40 BW160R 40 40 250A BW250E 40 40 BW250J 40 40 BW250S 40 40 BW250R 40 40 BW250H 60 60 400A BW400E 100 80 BW400S 100 80 BW400R 100 80 BW400H 100 80 630A BW630E 100 80 BW630R 100 80 BW630H 120 100 800A BW800E 100 80 BW800R 100 80 BW800H 120 100 Barrier D3 10 30 10 30 30 50 80 30 30 50 50 50 50 50 50 80 80 80 80 80 80 80 80 80 80 100 100 100 100 100 100 120 100 100 120 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, front connection BW32 -2P, BW50 -2P 46 C L 2.5 Panel drilling Terminal section M4 or o5 50 Insulation barrier Detachable Front panel cutting Mounting hole CL 43 MCCB CL MCCB 17 R2 s es 10 l or 7 CL M5x14 24 52 or more CL C L 42 C L 84 50 84 100 40 ON .5 Max. 15 8 Trip button 25 47.5 50 4 51 60 8 o5 84 t 4 7 50 or more Insulation barriers Standard provided: BW50SAG, BW50RAG Optional: BW32AAG, BW32SAG, BW50EAG BW32 -3P, BW50 -3P 46 2.5 Panel drilling Terminal section 06 43 CL MCCB ss le 10 or 17 C L MCCB CL R2 Mounting hole 50 Insulation barrier Detachable Front panel cutting M4 or o5 7 CL M5x14 24 52 or more CL C L 42 C L 84 50 84 100 40 ON .5 Max. 15 8 50 72 75 Trip button 4 51 60 8 o5 74 or more 25 84 t 4 7 Insulation barriers Standard provided: BW50SAG, BW50RAG Optional: BW32AAG, BW32SAG, BW50EAG BW63 -2P 46 C L Panel drilling Front panel cutting Terminal section M4 or o5 Mounting hole CL 43 MCCB CL MCCB R2 17 50 Insulation barrier Detachable 2.5 le 10 or ss 7 ON CL 24 52 or more CL C L 42 C L 84 50 84 100 40 M8 x 15 25 47.5 50 Trip button 4 51 60 8 50 or more Max. 15 8 o9 t6 7 84 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/39 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, front connection BW63 -3P 46 2.5 Panel drilling Terminal section MCCB CL 43 CL MCCB ss le 10 or 17 C L R2 Mounting hole 50 Insulation barrier Detachable Front panel cutting M4 or o5 7 CL 24 52 or more CL C L 42 C L M8 x 15 84 50 84 100 40 ON 8 Max. 15 o9 50 72 75 Trip button 4 51 60 8 84 25 74 or more Panel drilling Front panel cutting t6 7 BW100 -2P 46 C L Terminal section M4 or o5 Mounting hole CL 43 MCCB CL MCCB R2 17 50 Insulation barrier Detachable 2.5 ss le 10 or 7 ON CL 24 52 or more CL C L 42 C L 84 50 84 100 40 M8 x 15 8 Max. 15 o9 25 47.5 50 Trip button 4 51 60 8 50 or more 84 t6 7 M5 x 14 for BW100EAG-2P050 BW100 -3P 46 2.5 Panel drilling Terminal section MCCB CL 43 CL MCCB s le 10 or 17 C L R2 Mounting hole 50 Insulation barrier Detachable Front panel cutting M4 or o5 s 7 CL 24 52 or more CL C L 42 C L M8 x 15 84 50 84 100 40 ON 8 Max. 15 o9 50 72 75 Trip button 4 51 60 8 84 74 or more 25 Insulation barriers Standard provided: BW100EAG Optional: BW100AAG 06/40 t6 7 M5 x 14 for BW100EAG-3P050 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, front connection Panel drilling MCCB Mounting hole 60 C L 4 Front panel cutting M4 or o5 C L R2 132 C L 10 M8 x 16 3.5 7 64 68 95 BW50HAG-2P, 3P, BW125JAG-3P, BW125SAG-2P, 3P, BW125RAG-2P, 3P BW125HAG-2P, 3P Panel drilling C L MCCB Mounting hole C L 60 Front panel cutting M4 or o5 C L 4 R2 22 52 or more 50 3.5 7 64 68 95 s 10 8.5 C L M8 x 16 o9 87 or more t<6 Note: 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. 8 Panel drilling MCCB Insulation barrier Detachable 60 132 R2 C L 52 or more 15 50 30 o8.2 155 135 102 Trip button C L MCCB 57 or Terminal section MCCB C L ON 38 Front panel cutting 4 Mounting hole 22 M4 or o5 17 C L C L les s 10 C L 8.5 M8 x 16 C L o4.5 50 BW125JAG-4P BW125SAG-4P BW125RAG-4P 06 les 30 60 85 90 MCCB 24 Trip button 57 C L Terminal section o4.5 38 132 C L o8.2 155 135 102 15 50 ON or t<6 8 17 50 Insulation barrier Detachable o9 Max. 16.5 50 58 or more 30 56 60 8.5 C L 24 Trip button 57 s o4.5 15 38 C L o8.2 C L MCCB les 52 or more ON 15 50 155 135 102 22 or Terminal section 73.5 or more 43.5 or more 24 50 Insulation barrier Detachable 17 BW125JAG-2P o9 132 50 117 or more 30 30 72.5 75 120 30 42.5 45 3.5 7 C L t<6 64 68 95 8 30 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 30 M4 or *5 For V, N-type hadle 06/41 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, front connection 60 4 M4 or o5 R2 CL 57 Trip button les s 10.5 CL 80 64 68 95 7 11 M8 x 16 102 or more 35 3.5 70 100 105 MCCB 24 o8.2 45.5 126 CL or Terminal section o4.5 C L CL 52 or more ON 15 50 165 144 102 22 CL MCCB Mounting hole Front panel cutting 25.5 C L 80 Panel drilling Insulation barrier Detachable Max. 25 BW160 -2P, 3P BW250 -2P, 3P Note: 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. o9 t<6 8 BW160 -4P BW250 -4P Insulation barrier Detachable Trip button M4 or o5 57 52 or more 126 CL or CL CL Terminal section MCCB les s 10.5 CL 11 M8 x 16 86 or more 51 or more 24 45.5 CL ON o8.2 C L MCCB R2 15 50 Mounting hole 4 Front panel cutting 25.5 60 o4.5 80 C L 22 165 144 102 Panel drilling 35 35 85 87.5 140 06/42 35 50 52.5 3.5 7 64 68 95 137 or more Max. 25 80 35 o9 t<6 8 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, front connection BW400 -2P, 3P 4 44 CL MCCB R2 84 60 or les s CL 215 CL CL 127 102 90 24.5 CL MCCB CL o7 52 257 225 215 Front panel cutting 94.5 4 Mounting hole Panel drilling 92 or more Insulation barrier Detachable o13.5 105 140 135 88 44 146 117.5 103 41.5 16 41.5 Trip button 105 25 M6 or o7 8 56 137 or more 44 M12 x 35 bolt Note: 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. 56 CL 06 BW400 -4P Insulation barrier Detachable Panel drilling Mounting hole 44 CL o7 MCCB 60 CL CL 215 127 102 90 24.5 CL CL R2 84 52 257 225 215 Front panel cutting 94.5 4 or MCCB les s 92 or more 146 117.5 103 4 o13.5 105 185 135 132 CL 88 44 CL 52.5 52.5 38.5 Insulation barrier (removable) 210 44 4 4 70 7 70 C L 84 70 52 127 102 90 24.5 C L 243 275 MCCB 243 8 146 117.5 103 94.5 o13.5 Mounting hole 70 137 or more 44 M12 x 35 bolt 25 52.5 105 87 32 15 M6 or o7 8 o7 16 105 41.5 41.5 Trip button 93 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to205change without Trip button notice M6 or #7 C L MCCB 06/43 Ma x.R 2 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, front connection BW630 -3P 146 Panel drilling Mounting hole 70 94.5 4 70 7 MCCB C L o7 70 Front panel cutting 84 70 R2 or les s CL 243 127 102 90 24.5 243 275 52 CL MCCB C L min.92 44 o13.5 105 87 8 32 15 4 Insulation barrier Detachable 210 117.5 103 93 207 or more Trip button M6 or o7 M12 x 40 Hexagon head bolt 87 105 205 7 38.5 BW630 -4P Mounting hole 70 38.5 10 4 MCCB C L R2 2 CL C L C L 87 8 M12 x 40 Hexagon headM12 boltx 40 Hexagon head bolt 15 ss C L M6 or o7 10 32 105 87 105 s le Trip button 205 M6 or o7 70 207 or more 7 41.5 06/44 or 207 or more Trip button 205 les CL 243 102 90 127 93 MCCB C L 35 or R 127 102 90 24.5 C L C L MCCB 84 275 243 243 MCCB C L 94.5 84 75.5 275 70 7 243 52 94.5 Front panel cutting o7 70 4 o13.5 70 Front panel cutting 92 or more Insulation barrier Mounting holeDetachable 44 Panel drilling Panel drilling 103 4 min.92 4 Insulation barrier Detachable 70 70 o13.5 105 87 105 8 32 15 70 o7 280 210 146 146 117.5 103 117.5 70 70 38.5 44 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 2o Trip button M6 or o7 M12 x 40 Hexagon head bolt 87 105 min.92 243 93 205 ss CL Circuit Breakers Molded Case G-TWIN series 207 or more Dimensions / Standard CL 127 102 90 24.5 r le 243 275 52 7 38.5 n Dimensions, mm Front mounting, front connection BW800 -3P 44 Mounting hole 4 94.5 Panel drilling 84 70 CL MCCB C L R2 127 102 90 24.5 275 243 52 MCCB C L or les s CL 243 70 Front panel cutting 70 10 o13.5 70 4 min.92 Insulation barrier Detachable o7 105 87 8 32 15 210 146 117.5 103 93 207 or more Trip button 205 M6 or o7 105 87 M12 x 40 Hexagon head bolt 10 41.5 06 BW800 -4P 146 280 Panel drilling 117.5 70 70 4 Insulation barrier Detachable 105 Front panel cutting 103 38.5 7 Mounting hole 94.5 o13.5 4 MCCB 35 C L 84 o7 243 C L C L 8 M12 x 40 Hexagon head bolt 32 87 R2 or le ss C L Trip button 205 105 102 90 127 243 275 75.5 C L C L MCCB 92 or more 70 M6 or o7 7 70 207 or more 15 38.5 70 70 44 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/45 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X) BW32 -2P, BW50 -2P CL Panel drilling Pannel Terminal cover Terminal cover CL M4 or o5 CL 3 Mounting hole 8 Trip button 50.5 50 o6.5 (M6 x 18 bolt) 59 4 8 o22 8 47.5 95 45 84 CL 110 C L 110 137 84 50 CL 100 ON 68 25 MCCB 14 25 92 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. BW32 -3P, BW50 -3P C L Terminal cover Panel drilling Pannel Terminal cover C L C L M4 or o5 3 Mounting hole 8 72 95 45 110 C L 84 C L 110 137 100 50 C L 84 ON 25 o22 Trip button 75 o6.5 (M6 x 18 bolt) 59 4 8 50 8 50.5 68 MCCB 14 25 25 92 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. BW63 -2P CL CL M4 or o5 CL 3 Mounting hole Panel drilling Pannel Terminal cover Terminal cover 8 Trip button 50.5 50 59 4 8 68 92 8 47.5 95 45 84 CL 110 C L 110 137 100 50 CL 84 ON o6.5 (M6 x 18 bolt) o22 25 MCCB 14 25 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. 06/46 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X) BW63 -3P C L Terminal cover Panel drilling Pannel Terminal cover C L C L M4 or o5 3 Mounting hole 25 8 o22 Trip button 75 50.5 o6.5 (M6 x 18 bolt) 59 4 8 50 8 72 95 45 84 C L 110 C L 110 100 137 50 C L 84 ON 68 MCCB 14 25 25 92 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. BW100 -2P Mounting hole Panel drilling Pannel Terminal cover Terminal cover CL M4 or o5 CL 06 3 CL 8 Trip button 50.5 50 o6.5 (M6 x 18 bolt) 59 4 8 o22 8 47.5 95 45 84 CL 110 C L 110 100 137 50 CL 84 ON 68 25 MCCB 14 25 92 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. BW100 -3P C L Terminal cover Panel drilling Pannel Terminal cover C L C L M4 or o5 3 Mounting hole 8 o22 Trip button 75 50.5 8 72 95 45 110 C L 84 C L 110 100 137 50 C L 84 ON o6.5 (M6 x 18 bolt) 59 4 8 68 25 50 MCCB 14 25 25 92 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/47 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X) BW125JAG-2P Mounting hole Panel drilling Terminal cover Pannel 37 CL 5 5 CL MCCB ON 22 132 135 Insulation tubu Trip button 16 o8.5 (M8 x 25 bolt) 64 56 60 5 CL 15 15 37 2.5 87 CL 135 CL 50 155 102 15 3.5 7 68 95 o18 30 30 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. BW50HAG-2P, 3P, BW125JAG-3P BW125SAG-2P, 3P, BW125RAG-2P, 3P BW125HAG-2P, 3P Mounting hole Panel drilling Terminal cover 37 Pannel MCCB CL 5 5 CL M4 or o5 o8.5 (M8 x 25 bolt) CL Trip button 16 Insulation tubu 3.5 7 68 95 BW125JAG-4P BW125SAG-4P BW125RAG-4P M4 or o5 30 60 o18 30 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. Panel drilling MCCB Mounting hole CL Terminal cover 37 CL Pannel 45 CL 5 5 30 132 135 5 o8.5 (M8 x 25 bolt) 64 85 90 CL 2.5 87 15 15 37 135 CL 132 135 ON 50 155 102 22 30 15 15 2.5 37 87 CL 135 CL 50 155 102 ON Insulation tubu 22 Trip button M4 or o5 30 90 o18 MCCB CL 72.5 120 42.5 45 64 3.5 7 68 95 o8.5 (M8 x 25 bolt) 45 30 30 30 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. 132 135 5 16 CL 30 o18 30 M4 or o5 30 90 For V, N-type handle 06/48 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X) BW160 -2P, 3P BW250 -2P, 3P CL Pannel MCCB CL 3.5 7 100 105 64 68 95 22 57.5 93.5 14 20 o9 (M8 x 25 bolt) Trip button 126 144 CL 144 CL 5 CL ON 50 165 102 37 5 5 Mounting hole 22 Panel drilling Terminal cover o24 Max. 6 35 35 M4 or o5 70 35 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. BW160 -4P BW250 -4P CL 37 Pannel MCCB 06 CL 5 5 Panel drilling Terminal Mounting cover hole 35 ON 5 85 140 50 52.5 22 3.5 7 64 68 95 Max. 6 35 35 o9 (M8 x 25 bolt) 35 14 20 Trip button CL 126 144 57.5 93.5 52.5 CL 144 CL 50 165 102 22 M4 or o5 o24 35 35 35 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/49 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X) BW400 -2P, 3P Angle mounting CL CL 225 15 CL 13 31 12 4.5 140 106.5 44 44 o35 16 4 115 4.5 Insulation tube 60 158 44 44 Angle 5 5 M12 x 35 bolt 27 15 CL M6 or o7 15 257 266 102 90 Angle CL 215 ON CL 5 Special nut (supplied) 51 MCCB 160 8 4.5 Panel drilling MCCB Live section cover 5 Panel 225 Mounting hole CL 108 o7 44 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. 110 BW400 -4P Panel drilling Panel MCCB 15 M6 or o7 M12 x 35 bolt 106.5 4.5 4 115 158 16 44 44 44 o35 44 44 44 Angle 44 54 108 15 27 15 13 31 4.5 185 12 5 Insulation tube 70.5 CL 160 CL 215 Angle CL 225 257 266 102 90 ON MCCB 5 Special nut (supplied) 51 CL CL 5 Live section cover 225 8 CL Angle mounting CL 5 4.5 Mounting hole 60 110 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. 06/50 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice o7 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard n Dimensions, mm Front mounting, rear connection (type X) BW630 -3P Panel Panel drilling Angle mounting C L 5 C L MCCB 10 15 MCCB 11 C L 10 Mounting hole 52 C L 210 70 140 M6 or o7 Trip button 8 32 12 C L 4 4 106.5 115 129.5 158 20 85*1 15 Angle 40X40X5 5 11 43 125 10 93 Live section cover C L 160 Angle C L 243 127 102 90 C L 243 413 24.5 275 297 ON o48 o7 178 o13 M12X40Bolt 98 180 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Specify the stud directions when ordering. Contact FUJI. *1 Connectable area. 06 Insulation barrier 70 70 BW630 -4P Panel drilling C L 70 5 C L C L 75.5 Live section Live section cover 35 cover 15 10 5 MCCB C L 160 C L C L 70 70 140 5 15 10 M6 or o7 70 o48 Angle 40 x 40 5 Angle o48 40X40X5 o7 248 5 125 45 8 32 20 12 o13 M12 x 40 bolt 106.5 85*1 8 32 20 12 115 o4 129.5 98 M12X40Bolt 106.5 4 85*1 158 180 115 4 129.5 98 180 158 70 160 C L 10 Trip button 4 4 43 125 11 11 C L 210 C LMCCB 178 15 Angle 243 Angle 128 93 280 C L 243 C L 413 C L Angle mounting ON 243 127 127 102 102 90 90 C C LL ON 243 413 205 24.5 24.5 275 275 297 297 52 M6 orMCCB o7 MCCB 10 C L 11.5 Trip button C L 10 Mounting hole 11 11 Mounting hole Angle mounting Panel drilling 15 Panel Panel o7 Note: Ex-works, are mounted on the MCCB unit shownininthe the figure figure for Note: Ex-works , studsstuds are mounted on the MCCB unit asasshown for side sideview. view. line terminal side terminal : Mounted horizontally. *Studs*Studs for lineforside : Mounted horizontally. for load-side terminal : Mounted vertically. *Studs*Studs for load-side terminal : Mounted vertically. thedirections stud directions when ordering. Contact FUJI. SpecifySpecify the stud when ordering. Contact FUJI. *1 Connectable area.area. *1 Connectable Insulation barrier 70 70 70 Insulation barrier 70 70 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/51 C L Live section cover 4 4 106.5 115 129.5 158 M12X40Bolt 85*1 98 Molded Case Circuit Breakers G-TWIN series Dimensions / Standard 180 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Specify the stud directions when ordering. Contact FUJI. *1 Connectable area. Insulation barrier 70 70 n Dimensions, mm Front mounting, rear connection (type X) Panel 11 Angle mounting C L MCCB 5 C L 11.5 Mounting hole Panel drilling MCCB C L 10 15 BW800 -3P 52 C L 45 15 5 Angle o48 40X40X5 70 M6 or o7 140 Trip button Live section cover 125 11 210 C L 10 93 160 243 Angle 413 297 C L 243 24.5 C L 275 127 102 90 ON 8 12 4 4 C L 106.5 115 129.5 158 32 20 85*1 o7 178 o4 M12X40Bolt 98 180 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Specify the stud directions when ordering. Contact FUJI. 1 * Connectable area. Insulation barrier 70 70 BW800 -4P Panel drilling C L 43 125 11 280 C L 12 4 4 75.5 C L 106.5 115 129.5 158 8 32 85*1 98 20 70 70 70 Angle 40 x 40 5 15 10 128 35 MCCB 160 243 Angle C L 5 C L Live section cover C L 10 10 70 ON 243 413 24.5 275 297 205 127 102 90 C L MCCB Angle mounting 5 C L 11 Mounting hole M6 or o7 15 Panel Trip button 248 o7 o48 o13 M12 x 40 bolt 180 Note: Ex-works, studs are mounted on the MCCB unit as shown in the figure for side view. *Studs for line side terminal : Mounted horizontally. *Studs for load-side terminal : Mounted vertically. Specify the stud directions when ordering. Contact FUJI. 1 * Connectable area. Insulation barrier 70 06/52 70 70 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Global n Dimensions, mm Front mounting, front connection BW50RAGU-2P Panel drilling Mounting hole Front panel cutting 43 M4 or o5 MCCB MCCB C L CL 40 R2 s 8 C L 84 C L C L 52 or more 100 84 les 9.8 42 24 50 C L or 48.5 ON 8.3 M5 x 14 50 or more 25 50 Terminal section 2.5 17 51 24 Terminal cover (Short type) 9.8 C L 51 Trip button 60 4 8 84 06 BW50RAGU-3P Panel drilling 43 M4 or o5 CL MCCB MCCB CL R2 48.5 or les s 8 8.3 CL M5 x 14 24 52 or more CL 84 100 C L 42 50 C L 84 40 ON Terminal section 17 C L Front panel cutting 2.5 9.8 Mounting hole 51 Terminal cover (Short type) 9.8 25 75 74 or more 51 50 60 Trip button 4 8 84 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/53 Molded Case Circuit Breakers G-TWIN series Dimensions / Global n Dimensions, mm Front mounting, front connection BW100EAGU-2P Panel drilling Mounting hole Front panel cutting 43 M4 or o5 MCCB MCCB C L CL R2 8 s C L 84 C L C L 52 or more 100 84 les 9.8 42 24 50 40 C L or 48.5 ON 8.3 M8 x 15 50 or more 25 50 Terminal section 2.5 17 51 24 Terminal cover (Short type) 9.8 C L 51 Trip button 60 4 8 84 BW100EAGU-3P Panel drilling 43 M4 or o5 CL MCCB MCCB CL R2 48.5 or 8 les s CL M8 x 15 24 52 or more CL 84 100 C L 8.3 42 50 C L 84 40 ON Terminal section 17 C L Front panel cutting 2.5 9.8 Mounting hole 51 Terminal cover (Short type) 9.8 25 75 74 or more 51 50 60 Trip button 4 8 84 06/54 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Global n Dimensions, mm Front mounting, front connection BW125 U-2P, 3P 2-pole 3-pole (2-pole) Insuration barrier Detachable 15 50 102 Trip button Trip button CL C L C L M4 or o5 MCCB 57 30 50 50 C L M4 or o5 C L 8 8 MCCB 132 50 38 38 4 3-pole (2-pole) ON CL o8.2 15 155 CL 135 22 15 50 102 60 132 8 135 22 155 Mounting hole CL 8 50 Insuration barrier Detachable Mounting hole Panel drilling 2-pole o4.5 CL 30 60 3.5 64 56 85 7 68 60 90 95 Front panel cutting s or C L Terminal section Max. 16.5 les MCCB 8.5 R2 les 52 or more or 52 or more R2 CL MCCB s 06 o9 t<6 C L 17 24 10 C L 8 M8 x 16 58 or more Note: 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. 87 or more BW250 U-2P, 3P 3-pole (2-pole) Panel drilling 80 Insuration barrier Detachable 4 MCCB CL R2 57 or MCCB les 52 or more 45.5 CL o4.5 C L 126 15 50 ON C L CL M4 or o5 Mounting hole 22 165 144 102 60 o8.2 8 C L Front panel cutting s CL 8 Trip button 102 or more 7 64 68 95 Terminal section Max. 25 3.5 11 70 100 105 o9 t<6 25.5 10.5 80 35 24 8 M8 x 16 Note: 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/55 Molded Case Circuit Breakers G-TWIN series Dimensions / Global n Dimensions, mm Front mounting, front connection BW400 U-2P, 3P Mounting hole 4 44 CL 52 Front panel cutting MCCB 60 CL CL 215 127 102 90 CL MCCB CL R2 84 24.5 257 225 215 Panel drilling 94.5 4 o7 Insulation barrier Detachable 146 117.5 103 o13.5 105 140 135 88 44 or les s 92 or more 3-Pole (2-pole) CL 41.5 16 41.5 Trip button 105 25 56 M6 or o7 8 137 or more 44 M12 x 35 bolt Note: 2-pole breaker is supplied in 3-pole frame with current carrying parts omitted from center pole. 56 CL BW630 U-3P Panel drilling 146 4 Insulation barrier Detachable 38.5 4 94.5 70 7 C L MCCB 84 70 R2 CL CL 243 127 102 90 24.5 275 243 52 CL C L or MCCB les s 92 or more Mounting hole 70 70 Front panel cutting 117.5 103 o7 44 o13.5 105 87 8 32 15 210 CL CL 93 105 87 205 207 or more Trip button M6 or o7 M12 x 40 Hexagon head bolt 7 38.5 06/56 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Dimensions / Global n Dimensions, mm Front mounting, front connection BW800 U-3P Panel drilling 146 4 Insulation barrier Detachable 4 70 94.5 70 8 C L MCCB 84 70 R2 CL CL 243 127 102 90 24.5 275 243 52 CL C L or MCCB les s 92 or more Mounting hole 70 o7 44 Front panel cutting 117.5 103 41.5 o13.5 105 87 8 32 15 210 CL CL 93 105 87 205 207 or more Trip button M6 or o7 M12 x 40 Hexagon head bolt 8 41.5 06 Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/57 Molded Case Circuit Breakers G-TWIN series Characteristic curves n Characteristic curves / Line protection BW32, 50, 63, 100 Rated current: 5, 10, 32, 40, 60, 63, 70, 75, 80, 90A 60 40 Minute 60 40 20 20 10 6 4 2 1 40 1 40 20 20 Operating time Operating time 10 6 4 2 2 Max. value Min. value Instantaneous tripping characteristic 960%-1440% 0.2 0.1 0.06 0.04 0.02 0.01 1 0.6 0.4 Max. value Min. value 0.2 0.1 0.06 0.04 0.01 3 4 5 6 78 10 15 20 30 4050 70 100 400 2 0.02 1 1.5 2 Reference temp. 40 10 6 4 Second 1 0.6 0.4 Temperature correction curve Operating time correction ratio (%) Minute 180 120 10 6 4 Second Rated current: 3, 15, 20, 30, 50,100A 180 120 Instantaneous tripping characteristic 800%-1200% 1 1.5 2 Muitiple of rated current 350 300 250 200 150 100 50 -10 3 4 5 6 78 10 15 20 30 4050 70 100 Muitiple of rated current 20 30 40 0 10 Ambient temperature ( ) 50 BW50HAG, BW125 * 15A * 20A 10 6 4 20 10 6 4 2 Max. value 20 10 6 4 2 Max. value 1 40 20 20 20 Max. total fault clearing time Min. value 2 1 0.6 0.4 0.2 Instantaneous tripping characteristic 500A100A 0.1 0.06 0.04 0.02 0.01 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 5060 80100 Muitiple of rated current 10 6 4 2 Min. value Max. total fault clearing time 1 0.6 0.4 0.2 0.1 0.06 0.04 0.02 0.01 Second 10 6 4 Instantaneous tripping characteristic 500A100A 1 1.5 2 3 4 5 6 7 8 10 15 20 Operating time 1 40 Operating time 1 40 Second Operating time 180 120 60 40 Minute 20 2 Second * 30A 180 120 60 40 Minute Minute 180 120 60 40 30 40 50 60 80 100 Muitiple of rated current Max. value 10 6 4 Min. value 2 Max. total fault clearing time 1 0.6 0.4 0.2 Instantaneous tripping characteristic 500A100A 0.1 0.06 0.04 0.02 0.01 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 5060 80 100 Muitiple of rated current Temperature correction curve * 15-30A Reference temp. 40C Rated current correction ratio (%) 150 100 50 -10 0 10 20 30 40 50 Ambient temp. (C) 06/58 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Characteristic curves n Characteristic curves / Line protection BW50HAG, BW125 * 40A * 50-125A Minute 180 120 60 40 10 6 4 1 40 20 20 10 6 4 Max. total fault clearing time Min. value 2 1 0.6 0.4 0.2 Instantaneous tripping characteristic 500A100A 0.1 0.06 0.04 0.02 0.01 1 1.5 2 3 4 5 6 7 8 10 15 20 * 40-125A Reference temp. 40C 150 10 6 4 Max. total fault clearing time Min. value 2 1 0.6 0.4 Instantaneous tripping characteristic 10In20% 0.2 0.1 0.06 0.04 0.02 0.01 30 40 50 60 80 100 Temperature correction curve Max. value 2 1 40 Operating time Operating time 10 6 4 Max. value 2 Second 20 1 1.5 2 Muitiple of rated current 3 4 5 6 78 10 15 20 30 40 50 60 80 100 Muitiple of rated current Rated current correction ratio (%) 20 Second Minute 180 120 60 40 100 50 -10 0 10 20 30 40 50 Ambient temp. (C) BW160, 250 Minute 180 120 60 40 06 20 10 6 4 Max. value 2 Temperature correction curve 20 Reference temp. 40C 150 10 6 4 Min. value Max. total fault clearing time 2 1 0.6 0.4 100 Instantaneous tripping characteristic 10In20% 0.2 0.1 0.06 0.04 Rated current correction ratio (%) Second Operating time 1 40 0.02 0.01 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 60 80 Muitiple of rated current 50 -10 100 0 10 20 30 40 50 Ambient temp. (C) BW400 Minute 180 120 60 40 20 10 6 4 Max. value 2 Temperature correction curve 20 Reference temp. 40C 10 6 4 150 Min. value 2 Max. total fault clearing time 1 0.6 0.4 100 Instantaneous tripping characteristic 10In20% 0.2 0.1 0.06 0.04 Rated current correction ratio (%) Second Operating time 1 40 0.02 0.01 1 1.5 2 3 4 5 6 78 10 15 20 30 40 5060 80 100 Muitiple of rated current 50 -10 0 10 20 30 40 50 Ambient temp. (C) Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/59 Molded Case Circuit Breakers G-TWIN series Characteristic curves n Characteristic curves / Line protection BW630 Minute 180 120 60 40 20 10 6 4 Max. value 2 Temperature correction curve 20 Reference temp. 40C 150 10 6 4 Min. value Max. total fault clearing time 2 1 0.6 0.4 100 Instantaneous tripping characteristic 10In20% 0.2 0.1 0.06 0.04 Rated current correction ratio (%) Second Operating time 1 40 0.02 0.01 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 60 80 Muitiple of rated current 100 50 -10 0 10 20 30 40 50 Ambient temp. (C) BW800 Minute 180 120 60 40 20 10 6 4 Max. value 2 Temperature correction curve 20 Reference temp. 40C 10 6 4 150 Min. value Max. total fault clearing time 2 1 0.6 0.4 Rated current correction ratio (%) Second Operating time 1 40 100 0.2 Instantaneous tripping characteristic 640-960% 0.1 0.06 0.04 0.02 0.01 1 1.5 2 3 4 5 6 7 8 10 15 20 30 405060 80100 Muitiple of rated current 06/60 50 -10 0 10 20 30 40 50 Ambient temp. (C) Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Characteristic curves n Characteristic curves / Motor protection BW32, 50, 63, 100 180 120 Minute 60 40 20 10 6 4 2 1 40 Reference temp. 40 10 6 4 400 2 Instantaneous tripping characteristic 960%-1440% Min. value 1 0.6 0.4 Operating time correction ratio (%) Operating time Second Temperature correction curve Max. value 20 0.2 0.1 0.06 0.04 0.02 0.01 1 1.5 2 350 300 250 200 150 100 50 -10 3 4 5 6 78 10 15 20 30 4050 70 100 Muitiple of rated current 20 30 40 0 10 Ambient temperature ( ) 50 BW125 * 16A * 24A 10 6 4 20 10 6 4 2 Max. value 10 6 4 2 Max. value 1 40 20 20 20 Min. value 2 1 0.6 0.4 0.2 Instantaneous tripping characteristic 500A100A 0.1 0.06 0.04 0.02 0.01 1 1.5 2 3 4 5 6 78 10 15 20 30 40 5060 80100 Max. total fault clearing time Min. value 2 1 0.6 0.4 0.2 Instantaneous tripping characteristic 500A100A 0.1 0.06 0.04 0.02 0.01 Second Max. total fault clearing time 10 6 4 Operating time 1 40 10 6 4 1 1.5 2 3 4 5 6 7 8 10 15 20 Muitiple of rated current 06 20 1 40 Operating time Operating time 180 120 60 40 Minute Minute 20 2 Second * 32A 180 120 60 40 Second Minute 180 120 60 40 30 40 50 6080 100 Max. value 10 6 4 Max. total fault clearing time Min. value 2 1 0.6 0.4 0.2 Instantaneous tripping characteristic 500A100A 0.1 0.06 0.04 0.02 0.01 1 1.5 2 3 4 5 6 7 8 10 15 20 Muitiple of rated current 30 40 5060 80 100 Muitiple of rated current * 40-90A 20 10 6 4 Temperature correction curve * 15-32A Max. value 2 * 40-125A Reference temp. 40C Reference temp. 40C 150 150 20 10 6 4 Max. total fault clearing time Min. value 2 1 0.6 0.4 Instantaneous tripping characteristic 1200-1800% 0.2 0.1 0.06 0.04 0.02 0.01 Rated current correction ratio (%) Second Operating time 1 40 100 50 -10 1 1.5 2 3 4 5 6 7 8 10 15 20 Rated current correction ratio (%) Minute 180 120 60 40 0 30 40 5060 80 100 Muitiple of rated current Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 10 20 30 Ambient temp. (C) 40 50 100 50 -10 0 10 20 30 40 50 Ambient temp. (C) 06/61 Molded Case Circuit Breakers G-TWIN series Characteristic curves n Characteristic curves / Motor protection BW250 Minute 180 120 60 40 20 10 6 4 Max. value 2 Temperature correction curve 1 40 Reference temp. 40C 150 10 6 4 Min. value Max. total fault clearing time 2 1 0.6 0.4 0.2 Instantaneous tripping characteristic 1040A-1560A 0.1 0.06 0.04 Rated current correction ratio (%) Second Operating time 20 100 0.02 0.01 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 5060 80 100 Muitiple of rated current 06/62 50 -10 0 10 20 30 40 50 Ambient temp. (C) Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Accessories n Variation of internal accessory * 32 to100AF Auxiliary switch (Type W) Alarm switch (Type K) Shunt trip device (Type F) This switch is used for indicator lamp or control circuit. See page 06/69. This switch can be connected to a warning lamp or buzzer to indicate when the breaker has been tripped. See page 06/69. The purpose of this accessory is to trip the breaker from a distance. See page 06/70. Undervoltage trip device (Type R) The device is designed to protect circuits from harmful voltage drops. It can also be used for remote control purposes. The trip operates when the voltage drops to less than 70% of nominal coil rating, and the breaker cannot be reset until the voltage recovers 85% of its normal rating. See page 06/70. Terminal block (Type A) A wiring terminal for internal accessories (Order with W, K or F) See page 06/71. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/63 06 Molded Case Circuit Breakers G-TWIN series Accessories n Variation of internal accessory * 125 to 250AF Auxiliary switch (Type W) Alarm switch (Type K) Shunt trip device (Type F) This switch is used for indicator lamp or control circuit. See page 06/69. This switch can be connected to a warning lamp or buzzer to indicate when the breaker has been tripped. See page 06/69. The purpose of this accessory is to trip the breaker from a distance. See page 06/70. Undervoltage trip device (Type R) The device is designed to protect circuits from harmful voltage drops. It can also be used for remote control purposes. The trip operates when the voltage drops to less than 70% of nominal coil rating, and the breaker cannot be reset until the voltage recovers 85% of its normal rating. See page 06/70. Terminal block (Type A) A wiring terminal for internal accessories (Factory-mounted) See page 06/71. 06/64 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Accessories n Variation of internal accessory * 400 to 800AF Alarm switch (Type K) Shunt trip device (Type F) This switch can be connected to a warning lamp or buzzer to indicate when the breaker has been tripped. See page 06/69. The purpose of this accessory is to trip the breaker from a distance. See page 06/70. Terminal block (Type A) Undervoltage trip device (Type R) 06 A wiring terminal for internal accessories (Factory-mounted) See page 06/71. Auxiliary switch (Type W) The device is designed to protect circuits from harmful voltage drops. It can also be used for remote control purposes. The trip operates when the voltage drops to less than 70% of nominal coil rating, and the breaker cannot be reset until the voltage recovers 85% of its normal rating. See page 06/70. This switch is used for indicator lamp or control circuit. See page 06/69. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/65 Molded Case Circuit Breakers G-TWIN series Accessories n Variation of external accessory External operating handles * N-type See page 06/79. Terminal cover Long type See page 06/90. Steel enclosures See page 06/88. Mechanical interlock device See page 06/75. * V-type See page 06/79. Interphase barrier See page 06/92. Motor-operating mechanism See page 06/74. * F-type See page 06/79. Handle locking cover (L1) See page 06/93. Terminal cover Short type See page 06/91. Padlocking device See page 06/93. * Cap type (Q1, QN) * Plate type (Q2) 06/66 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Internal accessories n Terminal blocks for auxiliary circuit * It indicates the terminal No. of internal accessory.The connection method of internal accessory is lead-wire system and terminal block system. * For the available configuration of internal accessory, see page 06/68. Lead-wire wiring * Terminal With terminal block number of internal accessory 32 - 250AF Left side mounting Accessory Auxiliary switch Right side mounting 400 - 800AF Left side mounting SPDT: W (1)* 11 12 14 AXcL AXbL AXaL 21 22 24 AXcR AXbR AXaR 11 12 14 AXcL AXbL AXaL 21 22 24 AXcR AXbR AXaR 11 AXc 12 AXb 14 AXa 11 AXc 12 AXb 14 AXa 21 AXc 22 AXb 24 AXa 2PDT: V (2)* Alarm switch 06 SPDT: K (8)* 91 92 94 ALcL ALbL ALaL 01 02 04 ALcR ALbR ALaR 91 ALc 92 ALb 94 ALa 91 92 94 ALcL ALbL ALaL 01 02 04 ALcR ALbR ALaR 91 ALc 92 ALb 94 ALa 01 ALc 02 ALb 04 ALa 2PDT: J (9)* Shunt trip device : F With 1NO contact to prevent coil burn-out C2 S2 C1 S1 Continuous rating C2 S2 Undervoltage trip device : R C1 S1 U< D2 P2 D1 P1 Note: * ( ) Code of Low level circuit Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/67 Molded Case Circuit Breakers G-TWIN series Internal accessories n Available configurations 2-pole 3-pole Right MCCB Right Left Handle 4-pole Right Left Handle Shunt trip: F Undervoltage trip: R (External) Handle BW32-2P BW50-2P BW63-2P BW100-2P Undervoltage trip: R (Internal) BW125JAG-2P BW125JAGU-2P BW32-3P BW50-3P BW63-3P BW100-3P BW125 BW160 BW250 Auxiliary switch: W Alarm switch: K Lead wire BW400 BW630 BW800 (Except for BW125JAG-2P, BW125JAGU-2P) Pole 2 3 2 2, 3 4 2, 3, 4 Auxliary switch SPDT: W (1)* Alarm switch SPDT: K (8)* Shunt trip: F Undervoltage trip: R *2 *2 W+K (1+8) Auxliary switch 2PDT: V (2) Alarm switch 2PDT: J (9) V+K (2+8) W+J (1+9) V+J (2+9) W+F (1+F) W+R (1+R) *2 *1 *2 *2 *1 *2 *2 *1 *2 K+F (8+F) K+R (8+R) W+K+F (1+8+F) W+K+R (1+8+R) V+F (2+F) V+R (2+R) *2 *1 *2 *1 *2 *1 *2 *1 J+F (9+F) J+R (9+R) V+K+F (2+8+F) V+K+R (2+8+R) W+J+F (1+9+F) W+J+R (1+9+R) V+J+F (2+9+F) V+J+R (2+9+R) *1 *2 *1 *1 Notes: *The above table is applied to front mounting type, rear mounting type, flush mounting type, and plug-in mounting type. * Terminal block is attached on the same side of the accessory. * ( ) Code of low level circuit :See page 06/2. *1 Configurations with terminal block are not available. *2 Flush mounting, rear contection type breakers of 100AF or less are not available. 06/68 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Internal accessories n Operation of auxiliary switches(W) and alarm switches(K) Accessory Handle position ON Auxiliary switch 11/AXcL SPDT: W (1) OFF Trip 14/AXaL 11/AXcL 14/AXaL 12/AXbL 12/AXbL 11/AXcL 2PDT: V (2) 14/AXaL 11/AXcL 14/AXaL 12/AXbL 21/AXcR 12/AXbL 24/AXaR 21/AXcR 24/AXaR 22/AXbR 22/AXbR Alarm switch 94/ALaL 91/ALcL SPDT: K (8) 91/ALcL 92/ALbL 92/ALbL 91/ALcL 94/ALaL 2PDT: J (9) 91/ALcL 92/ALbL 01/ALcR ( n 94ALaL 92/ALbL 04/ALaR 01/ALcL 02/ALbR Note: 94/ALaL 04/ALaL 06 02/ALbL Ring mark indication ) Code of low level circuit Ratings of auxiliary switches(W) and alarm switches(K) * 32-100AF IEC60947-5-1 Voltage (V) Standard type Low level circuit 125 AC 250 AC - 125 DC 250 DC - Make/break current (A) AC 15 5 5 - - - - NECA C4505 Voltage (V) DC 13 - - - 0.6 0.3 - Make/break current (A) Res. load 5 3 4 0.4 0.2 0.1 125 AC 250 AC 30 DC 125 DC 250 DC 30 DC Minimum load current 5V DC 160mA 30V DC 30mA 5V DC 1mA * 125-800AF Rated thermal current (A) Standard type 5 Low level circuit 0.1 Rated operational current (A) AC Rated operational Res. load Voltage (V) 5 24 5 48 5 125 3 250 0.1 30 Ind. load 5 5 3 2 - Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice DC Rated operational Voltage (V) 24 48 125 250 30 Minimum load current Res. load Ind. load 4 2.5 0.4 0.2 0.1 3 1 0.4 0.2 - 5V DC 160mA 30V DC 30mA 5V DC 1mA 06/69 Molded Case Circuit Breakers G-TWIN series Internal accessories n Rating of shunt trip (F) MCCB type BW32 BW50 BW63 BW100 BW125 BW160 BW250 BW400 BW630 BW800 AC V VA DC V W 100-120 150 100-110 150 200-240 380-450 24 24 48 100-120 150 200 150 50 50 50 - - 24 24 48 100-110 - - 150 50 50 50 120-130 200-240 50 50 - 200-220 - 50 277 380-440 440-480 500-550 24-48 100-240 50 50 50 50 2 3 - - - - 24-48 100-220 - - - - 2 3 277 380-550 3 4 Code - - Time rating of coil FAC100-120V/ Continuous (With 1NO DC100-110V contact to FAC200-240V prevent coil burn-out) FAC380-450V FAC/DC24V FAC/DC24V FAC/DC48V FAC100-120V/ DC100-110V FAC120-130V FAC200-240V/ DC200-220V FAC277V FAC380-440V FAC440-480V FAC500-550V FAC/DC24-48V Continuous FAC100-240V DC100-220V FAC277V FAC380-550V Opearting time (ms) 7-13 13-21 8-20 Note: The operating tripping voltage range for shunt trip devices is 70% to 110% of the rated operating voltage. n Rating of undervoltage trip (R) MCCB type BW32 *2 BW50 *2 BW63 *2 BW100 *2 Installation External BW125 *1 BW160 *1 BW250 *1 Internal BW400 *2 BW630 *2 BW800 *2 Internal AC V 100 (50Hz)/ 100-110(60Hz) 200 (50Hz)/ 200-220 (60Hz) 400 (50Hz)/ 400-440 (60Hz) - - - - - 100-110 110-130 200-240 277 380-415 440-480 24 48 100-110 120-130 200-240 277 380-480 VA 2.8 DC V - W - 3.4 - - 4.4 - - - 24 100-110 24 48 100-110 125 - - - - - - 24 48 100-110 125 200-220 - - 40 - - - - 5 5 5 5 5 5 2 2 3 3 3 3 4 Code 5 5 5 5 - - - - - - 2 2 3 3 3 - - RAC100(50Hz)/ 100-110V(60Hz) RAC200(50Hz)/ 200-220V(60Hz) RAC400(50Hz)/ 400-440V(60Hz) RDC24V RDC100-110V RDC24V RDC48V RDC100-110V RDC125V RAC100-110V RAC110V-130V RAC200-240V RAC277V RAC380-415V RAC440V-480V RAC/DC24V RAC/DC48V RAC/DC100-110V RAC120-130V/DC125V RAC200-240V/DC200-220V RAC277V RAC380-480V Notes: * The operating voltages of undervoltage tripping devices are as follows: Tripping voltage: 35% to 70% of rated voltage, closing voltage: 85% to 110% of rated voltage. *1 Reset-allowed type: When the breaker handle is in the OFF or RESET state, tripping does not occur even if the R coil is not energized. Turning ON with the R coil not energized causes normal tripping. *2 Reset-prohibited type: When the R coil is not energized, reset operation cannot reset the tripped breaker to the OFF state. 06/70 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Internal accessories n Lead wire specification AF 32 to 100AF 125 to 250AF Pole - 2P, 3P 4P 2P, 3P 4P 400 to 800AF n Terminal wire size 0.4mm2 (AWG22) 0.5mm2 (AWG20) Wire length Ca 500mm 0.5mm2 Ca 500mm Ca 400 to 450mm blocks 125AF, 160AF, 250AF 32AF, 50AF, 63AF, 100AF 48.5 36 23.5 7 12.5 7 CL 30.2 53.7 77.2 CL C L 30.2 53.7 77.2 94 C L 12.5 48 C L 9 M3.5 12 27 39.3 51.5 06 400AF, 630AF, 800AF 38 19 8 CL 8 C L 100.5 77 53.5 30.5 6.5 117.5 81.5 69 56.5 44 Line Notes: * If the chosen combination has more than 8 terminals, 2 terminal blocks are mounted. * Mount the terminal block on the surface on which the accessories are mounted. See the table of the combinations of internal accessories on pages 06/68. for information on the accessory mounting position. * Available wire: Solid wire: 1.6o Stranded wire: 2mm2 * Terminal blocks are available as factory mounted only. M3.5 9.5 80 11 Terminal block * (Left) n Undervoltage Load (Right) trip device 32AF, 50AF, 63AF, 100AF 68 100 3 C L C L 41.5 C L M3.5 45 10.5 61 75 25 24 41 51 60 77 Mass: 0.15kg Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/71 Molded Case Circuit Breakers G-TWIN series Internal accessories n Type number Internal accessories (Sold separately) * 32, 50, 63, 100AF IEC/EN/GB/JIS conformed Accessory Auxiliary switch Auxiliary switch (low level circuit) Alarm switch Alarm switch (low level circuit) Auxiliary switch + Alarm switch Auxiliary switch + Alarm switch (low level circuit) Shunt trip device Undervoltage trip device Type Lead wire system Left side Right side Terminal block system Left side Right side Operating voltge BZ6WL10C BZ6WR10C BZ6WL10CA BZ6WDL10C BZ6WDR10C BZ6WDL10CA BZ6WDR10CA BZ6KL10C BZ6KR10C BZ6KL10CA BZ6KR10CA BZ6KDL10C BZ6KDR10C BZ6KDL10CA BZ6KDR10CA BZ6WKL10C BZ6WKR10C BZ6WKL10CA BZ6WKR10CA BZ6WDKDL10C BZ6WDKDR10C BZ6WDKDL10CA BZ6WDKDR10CA - BZ6FA10C - BZ6FA10CA 100-120V AC/100-110V DC - BZ6FK10C - BZ6FK10CA 200-240V AC - BZ6FP10C - BZ6FP10CA 380-450V AC - BZ6FR10C - BZ6FR10CA 24V AC/DC - - - BZ6R210C 100V AC 50Hz/100-110V AC 60Hz - - - BZ6R110C 110V AC 50Hz/110-127V AC 60Hz - - - BZ6RW10C 200V AC 50Hz/200-220V AC 60Hz - - - BZ6R410C 220V AC 50Hz/220-240V AC 60Hz - - - BZ6R510C 230V AC 50Hz/230-240V AC 60Hz - - - BZ6R810C 240V AC 50Hz - - - BZ6R010C 380V AC 50Hz 380-415V AC 60Hz - - - BZ6R910C 400V AC 50Hz 400-440V AC 60Hz - - - BZ6RF10C 24V DC - - - BZ6RT10C 100-110V DC BZ6WR10CA * 50, 100AF IEC/EN/GB/JIS/UL/CSA conformed Accessory Auxiliary switch Auxiliary switch (low level circuit) Alarm switch Alarm switch (low level circuit) Auxiliary switch + Alarm switch Auxiliary switch + Alarm switch (low level circuit) Shunt trip device Undervoltage trip device 06/72 Type Operating voltge Lead wire system Left side Right side Terminal block system Left side Right side BZ6WL10CU BZ6WR10CU BZ6WL10CAU BZ6WDL10CU BZ6WDR10CU BZ6WDL10CAU BZ6WDR10CAU BZ6KL10CU BZ6KR10CU BZ6KL10CAU BZ6KR10CAU BZ6KDL10CU BZ6KDR10CU BZ6KDL10CAU BZ6KDR10CAU BZ6WKL10CU BZ6WKR10CU BZ6WKL10CA BZ6WKR10CAU BZ6WR10CAU BZ6WDKDL10CU BZ6WDKDR10CU BZ6WDKDL10CAU BZ6WDKDR10CAU - BZ6FA10CU - BZ6FA10CAU 100-120V AC/100-110V DC - BZ6FK10CU - BZ6FK10CAU 200-240V AC - BZ6FP10CU - BZ6FP10CAU 380-450V AC - - - BZ6R210CAU 100V AC 50Hz/100-110V AC 60Hz - - - BZ6RW10CAU 110V AC 50Hz/110-127V AC 60Hz - - - BZ6R910CAU 200V AC 50Hz/200-220V AC 60Hz Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series Internal accessories * 125, 160, 250AF IEC/EN/GB/JIS/UL/CSA conformed Accessory Auxiliary switch Auxiliary switch (low level circuit) Alarm switch Alarm switch (low level circuit) Auxiliary switch + Alarm switch Auxiliary switch + Alarm switch (low level circuit) Shunt trip device Undervoltage trip devics Type Lead wire system Left side Right side Operating voltge Terminal block system Left side Right side * - BW9W1SG0 BW9W1SG0-R BW9W1SG0-A - BW9W1DG0 BW9W1DG0-R -* BW9K1SG0 BW9K1SG0-R BW9K1SG0-A BW9K1DG0 BW9K1DG0-R -* BW9WKSG0 BW9WK1SG0-R BW9WKSG0-A BW9WKDG0 BW9WK1DG0-R -* BW9FRG0 BW9FRG0 BW9FRG0-A 24V AC/DC BW9FSG0 BW9FSG0 BW9FSG0-A 48V AC/DC BW9FAG0 BW9FAG0 BW9FAG0-A 100-120V AC/100-110V DC BW9F1G0 BW9F1G0 BW9F1G0-A 120-130V AC BW9FKG0 BW9FKG0 BW9FKG0-A 200-240V AC/200-220V DC BW9FBG0 BW9FBG0 BW9FBG0-A 277V AC BW9FPG0 BW9FPG0 BW9FPG0-A 380-440V AC BW9FHG0 BW9FHG0 BW9FHG0-A 440-480V AC BW9FJG0 BW9FJG0 BW9FJG0-A 500-550V AC BW9RGAR - BW9RGAR-A 24V DC BW9RGAS BW9RGAS-A 48V DC BW9RGAL BW9RGAL-A 100-110V DC BW9RGA5 BW9RGA5-A 125V DC BW9RGAA BW9RGAA-A 100-110V AC BW9RGAT BW9RGAT-A 110-130V AC BW9RGAK BW9RGAK-A 200-240V AC BW9RGAB BW9RGAB-A 277V AC BW9RGAP BW9RGAP-A 380-415V AC BW9RGAH BW9RGAH-A 440-480V AC 06 Note: * Factory-mounted * 400, 630, 800AF IEC/EN/GB/JIS/UL/CSA conformed Accessory Auxiliary switch x 1 Auxiliary switch x 2 Auxiliary switch (low level circuit) x 1 Auxiliary switch (low level circuit) x 2 Alarm switch x 1 Alarm switch x 2 Alarm switch (low level circuit) x 1 Alarm switch (low level circuit) x 2 Shunt trip device Undervoltage trip devics Type Lead wire system Left side Terminal block system * Operating voltge BW9W1SHA - - BW9W2SHA BW9W1DHA BW9W2DHA BW9K1SHA BW9K2SHA BW9K1DHA BW9K2DHA BW9FHA-R 24-48V AC/DC BW9FHA-A 100-240V AC/100-220V DC BW9FHA-B 277V AC BW9FHA-P 380-550V AC BW9RHA-R 24V AC/DC BW9RHA-S 48V AC/DC BW9RHA-A 100-110 AC/DC BW9RHA-1 120-130V AC/125V DC BW9RHA-K 200-240V AC/200-220V DC BW9RHA-B 277V AC BW9RHA-P 380-480V AC Note: * Factory-mounted Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/73 Molded Case Circuit Breakers G-TWIN series External accessories Motor-operated breakers n Description The breaker is fitted with a motor operating mechanism which enables ON, OFF and RESET operations to be carried out electronically by remote control. The breakers do not conform to IEC and EN standard. n Type and ratings Motor rating MCCB type BW32-3P M, BW50-3P M, BW63-3P M, BW100-3P M Power source Mass (kg) capacity Operating voltage Operating time Time rating 100V DC 100/110V AC 200/220V AC 0.1s 15s per on-off operation 500VA 1.2 1.3 n Ordering information Specify the following: 1. Type number 2. Motor operating voltage n Dimensions, mm / Front mounting, front connection BW32 -3P, BW50 -3P, BW63 -3P, BW100 -3P, Panel cutting Panel drilling Mounting hole o4.5 M4 or o5 C L MCCB CL Operating handle CL 84 75 C L CL or m or e CL 10 50 84 100 R2 CL 52 or more 50 Insulation barrier 25 70 Terminal cover 75 4 51 67 Trip button 135 139 25 74 or more Mass: 1.2kg (BW32 or BW50 type with motor operating mechanism) 1.3kg (BW63 or BW100 type with motor operating mechanism) Notes: * Trip button operation can be carried out at right side of the breaker. * IEC 35mm wide mounting rail is not available. n Wiring diagrams 100/110V AC, 200/220V AC, 100V DC DRIVE UNIT 5 4 CONTROL CIRCUIT 3 E 2 1 OFF ON Power supply (Non polarity) 06/74 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories Mechanical interlocking devices n Description These interlocking devices are mounted on the two separate breakers to prevent them from both being closed at the same time. A sliding mechanism that can be locked with a padlock is used. (The padlock is not included.) They are designed for use when changing over power supplies. These can be mounted to 3 types of breakers: front-mounting front-connection type, front-mounting rear-connection type (type X), and plug-in mounting type (type P). Interlock devices for flush mounting type breakers (type E, Y) are also available. M1 types n Type and applicable breakers Type BZ6M110C2 BZ6M110C3 BW9M1CA-2 BW9M1CA-3 BW9M1CA-4 BW9M1GA-3 BW9M1GA-4 BW9M1HA-3 BW9M1HA-4 BW9M1JA-3 Breaker type BW32AAG-2P, BW32SAG-2P BW50AAG-2P, BW50EAG-2P, BW50SAG-2P, BW50RAG-2P BW63EAG-2P, BW63SAG-2P, BW63RAG-2P BW100EAG-2P BW32AAG-3P, BW32SAG-3P BW50AAG-3P, BW50EAG-3P, BW50SAG-3P, BW50RAG-3P BW63EAG-3P, BW63SAG-3P, BW63RAG-3P BW100AAG-3P, BW100EAG-3P BW125JAG-2P BW125JAG-3P, BW125SAG-2P, BW125SAG-3P, BW125RAG-2P, BW125RAG-3P BW125JAG-4P, BW125SAG-4P, BW125RAG-4P BW160EAG-2P, BW160EAG-3P, BW160JAG-2P, BW160JAG-3P BW160SAG-2P, BW160SAG-3P, BW160RAG-2P, BW160RAG-3P BW250EAG-2P, BW250EAG-3P, BW250JAG-2P, BW250JAG-3P BW250SAG-2P, BW250SAG-3P, BW250RAG-2P, BW250RAG-3P BW160JAG-4P, BW160SAG-4P, BW160RAG-4P BW250JAG-4P, BW250SAG-4P, BW250RAG-4P BW400EAG-2P, BW400EAG-3P, BW400SAG-2P, BW400SAG-3P BW400RAG-2P, BW400RAG-3P, BW400HAG-2P, BW400HAG-3P BW400RAG-4P, BW400HAG-4P BW630EAG-3P, BW630RAG-3P, BW630HAG-3P BW800EAG-3P, BW800RAG-3P, BW800HAG-3P Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06 06/75 Molded Case Circuit Breakers G-TWIN series External accessories n Dimensions, mm * 32AF to 100AF Panel drilling A B BZ6M110C2 C 85 Breaker Breaker 45 Breaker mounting hole 68 11 26 56 68 100 C L of slider CL of breaker C L of breaker C L Padlock (Not supplied) C L C L 2-o4.5 mounting hole 35 13 BZ6M110C3 C L 2-o4.5 or M4 110 Breaker Breaker 88 68 100 45 Breaker mounting hole CL of breaker C L Type C L 9 C L Dimensions, mm A B C BZ6M110C2 85 BZ6M110C3 110 42.5 55 C L 2-o4.5 or M4 Mass (kg) 83 0.11 108 0.12 Notes: * BZ6M110C2 is not available for padlock. * Applicable padlock(o3.5) dimensions, mm * External installation forms F and R are not applicable to the MCCB on the left of the diagram. 14 9.5 20 06/76 o3.5 14 12 o3.5 25 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories n Dimensions, mm * 125AF to 250AF Panel drilling A P N 25 M4 or o5 B 2-M4 or o4.5 76 145 ON D 37.6 87 145 165 11.7 C L of slider C L of breaker C L Breaker 15 C L C L Mounting screw: M4 x 10 (x2) Padlock (Not supplied) C L C L of breaker Breaker Fig.1 2-M4 or o4.5 M4 or o5 35 o19 15 C L 145 D 70.6 93 76 C 06 C L C L Breaker C L Breaker C L of breaker Fig.2 2-M4 or o4.5 2-M4 or o4.5 C M4 or o5 C L Breaker C LC L of breaker Breaker 145 D D 145 76 76 C Breaker C L Handle Fig.3 Type Breaker Fig.4 Dimensions, mm C L Handle C L of breaker Panel Drilling P N A B C BW9M1CA-2 90 88 150 60 - 132 Fig.1 BW9M1CA-3 120 118 210 90 30 132 Fig.2 BW9M1CA-4 150 148 270 102 30 132 Fig.4 BW9M1GA-3 135 133 240 105 35 126 Fig.3 BW9M1GA-4 170 168 310 140 35 126 Fig.4 Mass(Kg) D Notes: * The dimensions and Breaker mounting holes for back surface mounting are different from those given above. Inquire for details. * If a padlock is required, use a commercially available padlock with the dimensions shown in the diagram at the right. * External installation forms F and R are not applicable to the MCCB on the left of the diagram. 9.5 o3.5 12 M4 or o5 20 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/77 Molded Case Circuit Breakers G-TWIN series External accessories n Dimensions, mm * 400AF to 800AF C Lofhandle A C Lofhandle Paneldrilling A F C E C Lofslider J Breaker H J Handle C L Breaker L G D B K C Lofslider C Lofbreaker C Lofbreaker J J M6oro7 Padlock Mountingscrew (Notsupplied) Dimensions, mm Mass(Kg) A (A') B C D E F G H J (J') K L BW9M1HA-3 355 (70) 257 215 20 94.5 132.5 54.5 171 44 (70) 215 38 BW9M1HA-4 470 (140) 257 260 20 94.5 132.5 54.5 216 44 (140) 215 38 BW9M1JA-3 500 (105) 275 290 20 94.5 132.5 54.5 220 70 (105) 243 38 Notes: * The dimensions and Breaker mounting holes for back surface mounting are different from those given above. Inquire for details. * If a padlock is required, use a commercially available padlock with the dimensions shown in the diagram at the right. * External installation forms F and R are not applicable to the MCCB on the left of the diagram. 9.5 o3.5 12 Type 20 06/78 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories External operating handles n Description Molded case circuit breaker handles are generally directly manual-operated but when mounted in motor control centers or on control panels they are sometimes required to be operated externally. To meet such applications FUJI offers the following three types of handles. N type handle This type has a knob handle directly attached to the breaker. It is easily fitted by cutting a hole in the panel, which is provided with a door interlock. They may be fitted to all breakers up to 800 ampere frame sizes. Conformed to EN60947-1 isolation function. Available for EN60204-1 power breaking device. Conformed to UL489 (File No.E93289) V type handle The V type handle may be fitted to breakers of up to 800AF. A separately sold extension shaft provides distance adjustment between the handle and breaker. Conformed to EN60947-1 isolation function. Available for EN60204-1 power breaking device. Conformed to UL489 (File No.E93289) F type handle The F type handle may be fitted to breakers of 125 to 400AF. It is a flange type handle, which is commonly used in the North American market. The drive section of the breaker and the external operating handle are connected with an optional cable. Positioning between the breaker and the external operating handle is not required. BW9N0CA N type handles BW9V0CA V type handle N type handles Breaker 06 Decorative plate N type handle on breaker V type handles Breaker V type handle on panel F type handles Conformed to UL489 (File No.E93289) Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/79 Molded Case Circuit Breakers G-TWIN series External accessories F type handles N type handles MCCB BW32 BW50 BW63 BW100 BW125 BW160 BW250 BW400 BW630 BW800 N type handle BZ6N10D MCCB BW125 BW250 BW400 N type handle BW9F0CA BW9F0GA BW9F0HA BW9N0CA BW9N0GA BW9N0HA BW9N0JA V type handles MCCB BW32 BW50 BW63 BW100 BW125 BW160 BW250 BW400 BW630 BW800 V type handle BZ6V10D BW9V0CA BW9V0GA BW9V0HA BW9V0JA n Type number nomenclature * N type handle * F type handle BW9F0 BW9N0CA - Mounting (For BZ6N10D, BW9N0HA, BW9N0JA) Blank:Front mounting, front connection X: Front mounting, rear connection P: Plug-in mounting Basic type A Breaker type C: BW125 U G: BW250 U H: BW400 U Basic type Cable (For F type) BW9FW * V type handle BW9V0CA - Mounting (For BZ6V10D, BW9V0HA, BW9V0JA) Blank:Front mounting, front connection X: Front mounting, rear connection P: Plug-in mounting Basic type A Cable length 15: 1.5m 20: 2.0m 30: 3.0m Breaker type C: BW125 U G: BW250 U H: BW400 U Basic type Terminal cover (For F type) Note: To order a V handle for front-mounting rear connection breakers, add "-X" to the type number; for plug-in mounting breakers, add "-P" to the type number. 06/80 A- BW9FBT A - L3 Breaker type C: BW125 U G: BW250 U H: BW400 U Basic type Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories n Dimensions, mm N type handle * BZ6N10D C L Door panel cutting Load o90 C L 49 50 75 78 Thickness:1.2 to 3.2 H Dust proof packing Provided Provided 85 104 110 85 200 Note: Align the center of the hole cut in the panel with the center of the breaker handle. Handle type BZ6N10D BZ6N10D-X BZ6N10D-P 6 14 2.5 12 16 23 5 o1 C L 2.5 8 105 C L BW32 BW50 BW63 BW100 Padlock size o4 to o8 78 4- MCCB 38 Panel Mounting H (mm) screw M4 x 85 103 Contact FUJI. 111 111 17 23 105 Line C L 200 Install the hinge in the shaded area. Mass (kg) 0.47 06 * BW9N0CA, BW9N0GA 108 Door panel cutting Dust proof packing(Optional) Panel Line 4-o15 MCCB C L Handle C/L Handle C/L 200 200 85 85 Padlock size o4 to o8 50 7 1 15 39 21 78 Thickness: 1.2 to 3.2 Load Max.65 o90 MCCB Handle C/L 78 105 MCCB handle C/LCL 4 49 36 28 52.5 H Install the hinge in the shaded area. Note: Align the center of the hole cut in the panel with the center of the breaker handle. MCCB BW125 BW160 BW250 Handle type BW9N0CA*1 BW9N0GA*2 Dust proof packing BZ-NP-1C BZ-NP-1C Mounting screw M4 x 85 M4 x 85 H (mm) 1032 1032 Mass (kg) 0.56 0.56 Handle C/L 4P 3P 2P Notes: * The handle lock bars do not hold the entire door. Obtain a support bracket for the panel separately. * Remove the handle lock bar before opening the door. (Turn the handle in the open direction.) The lock bar will be damaged if the door is opened with force while the lock bar is engaged. * Engage the door interlock securely before turning ON the power. 1 * The Terminal Cover and Handle cannot be attached at the same time for the BW125JAG-2P or BW125RAGU-2P. Select the BW125JAG-3P or BW125RAGU-3P to use a Handle. *2 The terminal cover will cover the mounting screws for the Breaker. When attaching the terminal cover, a portion of the terminal cover will need to be removed. Remove portion A in the following diagram. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/81 Molded Case Circuit Breakers G-TWIN series External accessories * BW9N0HA, BW9N0JA 150 Line Mounting screw Door panel cutting Panel 112 5 o1 4- 96 Decorative plate 8 Load MCCB handle C/L Lock plate Padlock size o4 to o8 (Up to 2 o8 padlocks can be mounted.) MCCB handle C/L Panel thickness: 1.6-3.2 17 96 150 112 o13 MCCB handle C/L 53 1572 Handle C/L X-type 1692 P-type 1712 400AF 1742 630AF 2192 800AF 100 Note: Align the center of the hole cut in the panel with the center of the breaker handle. 65 65 35 35 25 15 7.5 25 100 200 200 Install the door hinge in the shaded area. MCCB BW400 BW630 BW800 Handle type BW9N0HA BW9N0HA-X BW9N0HA-P BW9N0JA BW9N0JA-X BW9N0JA-P Dust proof packing BZ-NP-2 BZ-NP-2 Mounting screw M6 x 110 M6 x 115 Contact FUJI. M6 x 110 M6 x 115 Contact FUJI. Mass (kg) 1.9 1.9 Notes: * The handle lock bars do not hold the entire door. Obtain a support bracket for the panel separately. * Remove the handle lock bar before opening the door. (Turn the handle in the open direction.) The lock bar will be damaged if the door is opened with force while the lock bar is engaged. * Engage the door interlock securely before turning ON the power. *Not available for side mounting. 06/82 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories n Dimensions, mm V type handle * BZ6V10D Door hinge installation area Door panel cutting Padlock size o4 to o8 56 73 o90 MCCB Handle C/L 38 15 113 MCCB handle C L C/L C L Handle C/L 4-o15 20 Panel 78 113 Line C L Panel thickness: 1.2 to 3.2 H Load 62 78 Note: Align the center of the hole cut in the panel with the center of the breaker handle. 50 75 Optional shaft BZ6VS1D 60 200 X = H - 105 Handle C/L X 3P Install the door hinge in the shaded area. 2P * BW9V0CA, BW9V0GA Door hinge installation area Door panel cutting 68 MCCB 4-o15 120 120 49 1 8 27 78 Panel thickness: 1.2 to 3.2 Load C L 60 41 78 113 o90 MCCB Handle C/L 27 60 MCCB handle C/L 65 06 C/L Handle C/L Note: Align the center of the hole cut in the panel with the center of the breaker handle. H 15 Panel C L 30 113 Line Install the door hinge in the shaded area. 49 Handle C/L Padlock size o4 to o8 Optional shaft BW9VSG0 4P 3P 2P X = H - 95 Shaft X Latch (included with the handle) Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/83 Molded Case Circuit Breakers G-TWIN series External accessories MCCB Handle type Optional shaft Standard type H BW32 BW50 BW63 BW100 BZ6V10D BZ6VS1D Mounting screw Mass (kg) 1052 With the optional shaft (X=154) Area in which the hinge H with H can be installed 2502 140 to 250 M4 x 80 0.64 BZ6V10D-X 1132 2582 150 to 258 Contact FUJI. 0.64 BZ6V10D-P 1132 2582 150 to 258 Contact FUJI. 0.64 1052 2502 140 to 250 M4 x 85 0.67 1052 2502 140 to 250 M4 x 85 0.67 BW125 BW9V0CA BW160*2 BW250*2 BW9V0GA BW9VSG0 Notes: * The handle lock bars do not hold the entire door. Obtain a support bracket for the panel separately. * Remove the handle lock bar before opening the door. (Turn the handle in the open direction.) The lock bar will be damaged if the door is opened with force while the lock bar is engaged. * Engage the door interlock securely before turning ON the power. *Not available for side mounting. *1 The Terminal Cover and Handle cannot be attached at the same time for the BW125JAG-2P or BW125RAGU-2P. Select the BW125JAG-3P or BW125RAGU-3P to use a Handle. *2 The terminal cover will cover the mounting screws for the Breaker. When attaching the terminal cover, a portion of the terminal cover will need to be removed. Remove portion A in the following diagram. 06/84 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories * BW9V0HA, BW9V0JA 150 Line Door panel cutting 112 Panel 0 o1 4- Decorative plate 8 112 MCCB handle C/L 150 OFF 150 o13 MCCB handle C/L MCCB handle C/L Mounting screw Panel thickness: 1.6-3.2 63 Note: Align the center of the hole cut in the panel with the center of the breaker handle. Load Lock plate Padlock size o4 to o8 (Up to 2 o8 padlocks can be mounted.) Optional shaft (BZ-VS2) 30 55 10 H X When using the BZ-VS2 extension shaft to adjust dimension H, cut it according to the equation below. X=H-161.5 06 100 200 Install the door hinge in the shaded area. MCCB Handle type Optional shaft Standard type H BW400 BW9V0HA BW9V0HA-X BW9V0HA-P BW9V0JA BW9V0JA-X BW9V0JA-P BW9V0JA BW9V0JA-X BW9V0JA-P BZ-VS2 1902 2022 2042 1902 2022 2072 1902 2022 2522 BW630 BW800 With the optional shaft (X=154) H Area in which the hinge with H can be installed 2502 202 to 250 2622 214 to 262 2642 216 to 264 2502 202 to 250 2622 214 to 262 2672 219 to 269 2502 202 to 250 2622 214 to 262 3122 264 to 312 Mass (kg) 2.2 Notes: * The handle lock bars do not hold the entire door. Obtain a support bracket for the panel separately. * Remove the handle lock bar before opening the door. (Turn the handle in the open direction.) The lock bar will be damaged if the door is opened with force while the lock bar is engaged. * Engage the door interlock securely before turning ON the power. *Not available for side mounting. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/85 Molded Case Circuit Breakers G-TWIN series External accessories n Dimensions, mm F type handle * BW9F0CA Drive section Operation section 100 104 70 80 65 Terminal cover Mounting screw M4 x 90 Handle ON 27 Panel 57 29 45 Concave for ON lock*2 155 Panel Lock lever 60 132 117 90 Release lever 149 Insulation barrier 145 275 Max. 69 150 *1 OFF lock Protection cover Release screw Cable 57 To operation section o7 2- 28 or more 12.5 RESET * This product consists of a drive section and an operation section. * The operation section can be mounted either to the right or to the left on the panel depending on the mounting position of the release lever. * For the OFF lock, 3 o10 padlocks can be mounted; for the ON lock, 2 o10 padlocks. *1 Set the height to 20 or 30. Adjust the lock lever depending on the setting. *2 The ON lock can be realized by additionally creating a concave for the ON lock. 119 75 22 132 5.5 2-o 27.5 30 R6 .5 27.5 29 M4 or o5 13 Panel drilling * BW9F0GA Drive section Operation section 115 104 70 80 88 Mounting screw M4 x 90 Handle ON 27 Panel 57 29 45 Concave for ON lock*2 165 Panel 117 60 Release lever 149 90 132 Lock lever Insulation barrier 145 275 Max. 69 150 *1 OFF lock Release screw Protection cover Cable To operation section 57 o7 2- 28 or more 27.5 27.5 29 13 Panel drilling R6 .5 119 75 22 126 5.5 2-o M4 or o5 06/86 RESET 12.5 35 * This product consists of a drive section and an operation section. * The operation section can be mounted either to the right or to the left on the panel depending on the mounting position of the release lever. * For the OFF lock, 3 o10 padlocks can be mounted; for the ON lock, 2 o10 padlocks. *1 Set the height to 20 or 30. Adjust the lock lever depending on the setting. *2 The ON lock can be realized by additionally creating a concave for the ON lock. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories * BW9F0HA Drive section Operation section 155 Protection cover 80 Handle 108 190 Mounting screw M6 x 110 27 Panel 57 Insulation barrier ON 29 45 Concave for ON lock*2 275 Panel Lock lever 60 Release lever 145 Cable 57 M6 or o7 o7 2- RESET 27.5 12.5 28 or more 13 27.5 29 119 75 22 5.5 2-o 214 to 216 OFF lock Release screw 171 To operation section 44 149 140 132 275 Max. 69 150 *1 R6 .5 06 * This product consists of a drive section and an operation section. * The operation section can be mounted either to the right or to the left on the panel depending on the mounting position of the release lever. * For the OFF lock, 3 o10 padlocks can be mounted; for the ON lock, 2 o10 padlocks. 1 * Set the height to 20 or 30. Adjust the lock lever depending on the setting. *2 The ON lock can be realized by additionally creating a concave for the ON lock. Panel drilling MCCB * BW125JAGU-3P BW125RAGU-2P BW125RAGU-3P BW250EAGU-2P BW250EAGU-3P BW250JAGU-2P BW250JAGU-3P BW250RAGU-2P BW250RAGU-3P BW400EAGU-2P BW400EAGU-3P BW400SAGU-2P BW400SAGU-3P BW400RAGU-2P BW400RAGU-3P BW400HAGU-2P BW400HAGU-3P Handle type BW9F0CA BW9F0GA BW9F0HA Cable Type BW9FWCA-15A BW9FWCA-20A BW9FWCA-30A BW9FWGA-15A BW9FWGA-20A BW9FWGA-30A Length (m) 1.5 2.0 3.0 1.5 2.0 3.0 Terminal cover BW9FWHA-15A BW9FWHA-20A BW9FWHA-30A 1.5 2.0 3.0 BW9FBTCA-L3 BW9FBTGA-L3 BW9FBTHA-L3 Note: * Not available for BW125JAGU-2P Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/87 Molded Case Circuit Breakers G-TWIN series External accessories Steel enclosures Description Steel enclosures are available in three types -- two with V-type handle which allows the operation from the outside and other with the operating handle of the breaker extending from it to allow it to be directly switched ON or OFF from outside the enclosure. Enclosures with V-type handles are provided with a door interlocking mechanism which prevents the door from being opened in the ON condition. Knockout holes for wiring use are provided as shown in the diagram. Type Standard Dustproof AF96-175 Rainproof CP97-2636 of enclosures MCCB Enclosure Standard *1 With V-type handle Dustproof *1*2 BW9UVBA-3A *3 Rainproof *1*2 BW32 BW50 BW63 BZ6C10C2 *3 BZ6C10C3 BW9UWBA-3A *3 BW100 BZ6C25C2 *3 BZ6C25C3 *3 BW9UVBA-3B *3 BW9UWBA-3B *3 BW125 BW9UCCA-2 BW9UCCA-3 BW9UVCA-3 BW9UWCA-3 BW250 BW9UCGA-3 BW9UVGA-3 BW9UWGA-3 BW400 BZ-C60B BW9UVHA-3 BW9UWHA-3 BW630 BW800 BZ-C70B BW9UVJA-3 - *1 No models are available for four-pole products. *2 The appearance of dust-proof and rain-proof models differs from the photograph (400A frames and higher). *3 Combination with external accessories(R) is not possible. Ordering information Specify the following: 1. Type number of enclosures 06/88 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories Dimensions, mm Fig.1 Standard Fig.2 With V type handle BW9UVBA-3A, BW9UVBA-3B BW9UVCA-3, BW9UVGA-3 C 9 R3.5(o7) D A E C L R6.5(o13) F B CL P ON T SE RE F B OFF I TR MCCB J Neutral terminal (Special order) Mounting hole o7 E A oL lead hole C Mounting hole P 2-K lead hole H H 4-L lead hole J Earth terminal M6 G G Earth terminal M6 Fig3. With V type handle BW9UVHA-3, BW9UVJA-3 06 A E C L method diagrams a b LINE c F B Connection D C LINE LOAD Mounting hole P C L 2-K lead hole 4-L lead hole H LOAD LINE LOAD Earth terminal M6 G Type BZ6C10C2 BZ6C10C3 BZ6C25C2 BZ6C25C3 BW9UCCA-2 BW9UCCA-3 BW9UCGA-3 BZ-C60B BZ-C70B BW9UVBA-3A BW9UVBA-3B BW9UVCA-3 BW9UVGA-3 BW9UVHA-3 BW9UVJA-3 Connection a, b, c Fig. 1 A 135 B 225 C 95 D - E 90 F 170 G 65 H 40 J 25 K - L o35, o22 P - 200 320 95 - 120 240 80 40 25 - o45, o30 - 200 320 103 - 120 240 80 40 25 - o45, o30 - 400 360 750 175 - 300 280 650 200 45 80 100 - o55, o40 o106, o78, o63 - 2 180 250 300 400 114 142 178.5 206.5 207 100 170 220 320 70 110 40 50 - - - o23 o28, o35, o43 o35, o52, o63 o7 o9 3 400 750 206 269 300 650 200 80 - o28 o63, o78, o106 o12 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/89 Molded Case Circuit Breakers G-TWIN series External accessories Terminal covers Description These terminal covers are used as guards to prevent accidental touch with live line terminations. These terminal covers can be fitted to either line or load side. l Up to 400AF Short type: BW9BT A-S * Snap-on fitting Long type: BW9BT A-L * Crimp connection use n 630, 800AF Long type: BW9BTJA-L * Transparent l Short type Long type Long type Gray BW9BTAA-L2W 2 BW9BTAA-L3 BW9BTAA-L3W 2, 3 BW9BTCA-L2 BW9BTCA-L3 BW9BTCA-L2W BW9BTCA-L3W 2 2, 3 BW9BTCA-C3 - 2, 3 BW9BTCA-L4 BW9BTCA-L4W 4 BW9BTGA-L3 *1 BW9BTGA-L3W *1 2, 3 BW9BTGA-L4 *1 BW9BTGA-C3 BW9BTGA-L4W *1 4 - 2, 3 BW9BTGA-L3 *1 BW9BTGA-L3W *1 2, 3 BW9BTGA-L4 *1 BW9BTHA-L3 *2 BW9BTGA-L4W *1 4 BW9BTHA-L3W *1 2, 3 BW9BTHA-L4 *2 BW9BTJA-L3 - BW9BTJA-L3W 4 3 BW9BTJA-L4 BW9BTJA-L4W 4 06/90 No. of poles MCCB BW32 -2P BW50 -2P BW63 -2P BW100 -2P BW32 -3P BW50 -3P BW63 -3P BW100 -3P BW125JAG-2P BW50HAG-2P BW50HAG-3P BW125RAG-2P BW125HAG-2P BW125 -3P BW125RAG-2P BW125 -3P BW125JAG-4P BW125RAG-4P BW160 -2P BW160 -3P BW160 -4P BW250 -2P BW250 -3P BW250 -2P BW250 -3P BW250 -4P BW400 -2P BW400 -3P BW400 -4P BW630 -3P BW800 -3P BW630 -4P BW800 -4P Dimensions (mm) A B C 50 40 53 Packing quantity Appearance 2 * Preventing exposure of live section when amplifier's terminals are connected * Snap-on mounting 75 40 53 2 60 90 40 40 66.5 66.5 2 2 90 60 66.5 2 120 40 66.5 2 105 50 66.5 2 140 105 50 75 66.5 66.5 2 2 105 50 66.5 2 140 172 50 110 66.5 98 2 2 220 230 110 135 98 97.5 2 2 280 155 98 2 C A B Type Transparent BW9BTAA-L2 MCCB Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories Short type Gray BW9BTAA-S2W No. of poles MCCB 2 BW9BTAA-S3 BW9BTAA-S3W 2, 3 BW9BTCA-S2P20 BW9BTCA-S2WP20 2 BW9BTCA-S3P20 BW9BTCA-S3WP20 2, 3 BW9BTCA-S4P20 BW9BTCA-S4WP20 4 BW9BTGA-S3P20 *1 BW9BTGA-S3WP20 *1 2, 3 BW9BTGA-S4P20 *1 BW9BTGA-S4WP20 *1 4 BW9BTHA-S3 *3 BW9BTHA-S3W *2 2, 3 BW9BTHA-S4 *3 BW9BTHA-S4W *2 4 BW32 -2P BW50 -2P BW63 -2P BW100 -2P BW32 -3P BW50 -3P BW63 -3P BW100 -3P BW125JAG-2P BW50HAG-2P BW50HAG-3P BW125RAG-2P BW125HAG-2P BW125 -3P BW125JAG-4P BW125RAG-4P BW160 -2P BW160 -3P BW250 -2P BW250 -3P BW160 -4P BW250 -4P BW400 -2P BW400 -3P BW400 -4P Dimensions (mm) A B C 50 10 53 Packing Appearance quantity 75 10 53 2 60 90 8 8 66.5 66.5 2 2 120 8 66.5 2 105 8 66.5 2 140 8 66.5 2 140 65 98 2 185 65 98 2 2 * Preventing exposure of live section when amplifier's terminals are connected * Snap-on mounting C A B Type Transparent BW9BTAA-S2 MCCB Notes: * A gray-white terminal cover comes standard with the Global Series 125AF and 250AF. *1 When using the external operating handle, part of the terminal cover ( ) must be cut away. *2 Crimp terminals for 325 mm2 are not available. 3 * This type of cover can be mounted on the 400AF when flat terminals are not used. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06 06/91 Molded Case Circuit Breakers G-TWIN series External accessories Insulation barriers Description The interphase barriers are provided on frame size of 32AF to 800AF breakers for front mounting. The barriers are installed in the molded slots between terminals. The earth barrier is used to increase the insulation with the mounting plate surface when two crimp terminals are wired. Installation of these barriers after wiring is possible even when an external accessory is installed. n Earth barrier Interphase barrier Interphase barrier Interphase barrier B Packing quantity Mass (g) 4 23 BW9BPCA BW9BPGA 50 80 60 60 2 2 15 25 B-43A 105 95 4 130 Dimensions (mm) A B 100 43 (50, 75)*1 (30)*1 Packing quantity Mass (g) 1 33 125 43 (75, 100)*1 (30)*1 1 41 Breaker BW32 BW50AAG, EAG BW50SAG, RAG BW63 BW100 BW50HAG, BW125 BW160 BW250 BW400 BW630 BW800 Interphase barrier Type Dimensions (mm) A B BZ6B10C 50 49 A MCCB Earth barrier BW32 -2P BW50 -2P BW63 -2P BW100 -2P BW32 -3P BW50 -3P BW63 -3P BW100 -3P Earth barrier Type BZ6BL10C2 Earth barrier A B MCCB BZ6BL10C3 Breaker Note: *1 Can be cut to dimensions 06/92 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Molded Case Circuit Breakers G-TWIN series External accessories Padlocking device and handle locking cover Description * Padlocking device n These padlocking device lock the Breaker handle in the OFF position. Use a commercially available padlock with a shackle diameter of 3.5 to 5mm (5mm for the BZ6L10CA). * Handle locking covers (Order Separately) These simple handle locking covers can be easily installed by the user. Tripping is possible while the Breaker is locked ON. MCCB Padlocking device Q1: Cap type BZ6L10CA Padlocking device * Cap type Q1,QN Handle locking cover Handle locking cover QN: Scissors type - BW32 BW50AAG, EAG, SAG, RAG BW63 BW100 BW50HAG, BW125 BW9Q1CA *5 BW160 BW250 BW400 *1 BW630 BW800 BW9QNHA *2 Q2: Plate type 1 4 ** BZ6L10C BW9Q2CA *3 BW9Q2GA BW9L1CA BW9Q2HA BW9Q2JA BW9L1HA Notes: *1 Specify Locks when ordering the Breaker. (: Factory-mounted) *2 ON and OFF locking is possible. *3 Not applicable to the BW125JA -2P (models with a width of 60 mm). *4 If a padlock is required, use a commercially available padlock with the dimensions shown in the diagram at the right. *5 Three padlocks with shackles from 3.5 to 8 mm in diameter can be attached. 06 (20) o5 35 Padlocking device * Cap type Q1 Handle locking cover * Plate type Q2 Q1: BZ6L10CA (OFF-locking Padlocking device) MCCB 9.5 5 o4 o3.5 .5 OFF 12 29.5 22 3- C L 6 6 C L 46 21.8 20 Padlock 3.5 7.8 3.5 95 Padlock (Obtain a commercially available lock conforming to the diagram at the right.) Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 06/93