PBA/PBW-16
MODEL
PBA300F-3R3
PBA300F-5
PBA300F-7R5
PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48
MAX OUTPUT WATTAGE[W] 198 300 300 324 330 336 324 336
DC OUTPUT
ACIN 100V
3.3V 60A 5V 60A 7.5V 40A 12V 27A 15V 22A 24V 14A 36V 9A 48V 7A
ACIN 200V
*3
3.3V 60A 5V 60A 7.5V 40A 12V 27A 15V 22A
24V 14(16.5)A
36V 9A 48V 7A
SPECIFICATIONS
MODEL
PBA300F-3R3
PBA300F-5
PBA300F-7R5
PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *4)
CURRENT[A]
ACIN 100V
3typ 4.1typ
ACIN 200V
1.6typ 2typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
68typ 74typ 76typ 78typ 78typ 79typ 81typ 79typ
ACIN 200V
71typ 77typ 79typ 81typ 81typ 82typ 84typ 82typ
POWER FACTOR
ACIN 100V
0.98typ (Io=100%)
ACIN 200V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More then 3 sec. to re-start)
ACIN 200V
40/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More then 3 sec. to re-start)
LEAKAGE CURRENT[mA] 0.45/0.75max (ACIN 100V/240V 60Hz,Io=100%,According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]
ACIN 100V
60 60 40 27 22 14 9 7
ACIN 200V
*3
60 60 40 27 22 14(16.5)97
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]
0 to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-20 - 0C
*1
140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]
0 to +50C
*1
120max 120max 150max 150max 150max 150max 200max 200max
-20 - 0C
*1
160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
40max 50max 75max 120max 150max 240max 360max 480max
-20 to +50C
60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV]
*2
12max 20max 30max 48max 60max 96max 144max 192max
START-UP TIME[ms]
300typ(ACIN 100/200V,Io=100%)*Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms] 20typ (ACIN 100/200V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.3 - 6.3 6.5 - 8.0 9.0 - 11.6 14.4 - 18.6 18.0 - 23.3 28.8 - 37.2 43.2 - 54.0 57.6 - 80.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Provided
REMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 102X42X170mm [4.02X1.65X6.69 inches] (without terminal block and screw)(
WXHXD)/1.0kg max
COOLING METHOD Forced cooling (internal fan)
*6
*1Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3() means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4 Derating is required.Consult us for details.
*5Please contact us about safety approvals for the model with option.
*6Please contact us about class C.
*A sound may occur from power supply at pulse loading.
PBA300F
AC-DC Power Supplies Enclosed Type
PB A 300 F -5 -O
Ordering information
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *5
C :with Coating
G:Low leakage current
U :Operation stop voltage
is set at a lower value
F3
:Reverse air exhaust
type
F4
:Low speed fan
N1
:with DIN rail
Refer to instruction manual
7.1.
R
123456
PBA/PBW
PBA/PBW-16
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
2-M4
4-M4
Mounting Hole
Name plate
CN1
Output voltage
adjustable potentiometer
LED
Terminal cover
CN2
CN3
Name plate
M4
M4
Output terminal(+)
Output terminal(-)
AC(N)
AC(L)
AIR FLOW
¶ Tolerance : ±1 [±0.04]
¶ Weight : 1.0kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [ ]= inches
¶ Mounting torque : 1.2N • m max
¶ Screw tightening torque : 1.6N • m max
¶ The housing for the remote sensing unused is mounted on CN1
170 6max
50.5 102
42
(14)
(15.5)
8.6
(23.5)
25max
(87)
(30)
28.5
[1.12]
[0.61]
[0.55]
[1.18]
[2.52]
[2.91][2.13]
[0.98]
[6.69] [0.24]
[1.65] [1.99]
[3.43]
[2.95]
[0.93]
[1.97]
[0.47]
[0.47]
[0.34]
[0.39][0.28]
[0.24]
[4.02] [0.79]
[0.47]
64±0.5
(6)
10 7
(50)
12
12
20
±
0.5
54 74±0.5
(75)
12
H
V.ADJ
¶ Please connect safety ground to FG terminal on the unit.
FG(
)
Mounting Hole
(Bottom side)
PBA/PBW
PBA/PBW-17
PBA300F
Block diagram
250V10A
INRUSH
CURRENT
LIMIT
RECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M
±S(REMOTE SENSING)
NOISE
FILTER
SWITCHING
DEVICE
CONTROL
RECTIFIER
AND
FILTER
RECTIFIER
AND
FILTER
VOLTAGE
SENSING
ACTIVE FILTER
VOLTAGE
SENSING CURRENT
SENSING
INVERTER
CONTROL
ALARMFAN
INTERNAL
REGULATOR
CONTROL
MASTER
SLAVE
CONTROL
THERMAL
PROTECTION
CURRENT
SENSING
AC IN
FG
FUSE
85
-
264V
OVER VOLTAGE
PROTECTION
External view
PBA/PBW
PB_E.indd 16 15.6.18 5:47:46 PM
PBA/PBW-17
MODEL
PBA300F-3R3
PBA300F-5
PBA300F-7R5
PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48
MAX OUTPUT WATTAGE[W] 198 300 300 324 330 336 324 336
DC OUTPUT
ACIN 100V
3.3V 60A 5V 60A 7.5V 40A 12V 27A 15V 22A 24V 14A 36V 9A 48V 7A
ACIN 200V
*3
3.3V 60A 5V 60A 7.5V 40A 12V 27A 15V 22A
24V 14(16.5)A
36V 9A 48V 7A
SPECIFICATIONS
MODEL
PBA300F-3R3
PBA300F-5
PBA300F-7R5
PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *4)
CURRENT[A]
ACIN 100V
3typ 4.1typ
ACIN 200V
1.6typ 2typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
68typ 74typ 76typ 78typ 78typ 79typ 81typ 79typ
ACIN 200V
71typ 77typ 79typ 81typ 81typ 82typ 84typ 82typ
POWER FACTOR
ACIN 100V
0.98typ (Io=100%)
ACIN 200V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More then 3 sec. to re-start)
ACIN 200V
40/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More then 3 sec. to re-start)
LEAKAGE CURRENT[mA] 0.45/0.75max (ACIN 100V/240V 60Hz,Io=100%,According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]
ACIN 100V
60 60 40 27 22 14 9 7
ACIN 200V
*3
60 60 40 27 22 14(16.5)97
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]
0 to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-20 - 0C
*1
140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]
0 to +50C
*1
120max 120max 150max 150max 150max 150max 200max 200max
-20 - 0C
*1
160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
40max 50max 75max 120max 150max 240max 360max 480max
-20 to +50C
60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV]
*2
12max 20max 30max 48max 60max 96max 144max 192max
START-UP TIME[ms]
300typ(ACIN 100/200V,Io=100%)*Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms] 20typ (ACIN 100/200V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.3 - 6.3 6.5 - 8.0 9.0 - 11.6 14.4 - 18.6 18.0 - 23.3 28.8 - 37.2 43.2 - 54.0 57.6 - 80.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Provided
REMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 102X42X170mm [4.02X1.65X6.69 inches] (without terminal block and screw)(
WXHXD)/1.0kg max
COOLING METHOD Forced cooling (internal fan)
*6
R
2-M4
4-M4
Mounting Hole
Name plate
CN1
Output voltage
adjustable potentiometer
LED
Terminal cover
CN2
CN3
Name plate
M4
M4
Output terminal(+)
Output terminal(-)
AC(N)
AC(L)
AIR FLOW
¶ Tolerance : ±1 [±0.04]
¶ Weight : 1.0kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [ ]= inches
¶ Mounting torque : 1.2N • m max
¶ Screw tightening torque : 1.6N • m max
¶ The housing for the remote sensing unused is mounted on CN1
170 6max
50.5 102
42
(14)
(15.5)
8.6
(23.5)
25max
(87)
(30)
28.5
[1.12]
[0.61]
[0.55]
[1.18]
[2.52]
[2.91][2.13]
[0.98]
[6.69] [0.24]
[1.65] [1.99]
[3.43]
[2.95]
[0.93]
[1.97]
[0.47]
[0.47]
[0.34]
[0.39][0.28]
[0.24]
[4.02] [0.79]
[0.47]
64±0.5
(6)
10 7
(50)
12
12
20
±
0.5
54 74±0.5
(75)
12
H
V.ADJ
¶ Please connect safety ground to FG terminal on the unit.
FG(
)
Mounting Hole
(Bottom side)
PBA/PBW
PBA/PBW-17
PBA300F
Block diagram
250V10A
INRUSH
CURRENT
LIMIT
RECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M
±S(REMOTE SENSING)
NOISE
FILTER
SWITCHING
DEVICE
CONTROL
RECTIFIER
AND
FILTER
RECTIFIER
AND
FILTER
VOLTAGE
SENSING
ACTIVE FILTER
VOLTAGE
SENSING CURRENT
SENSING
INVERTER
CONTROL
ALARMFAN
INTERNAL
REGULATOR
CONTROL
MASTER
SLAVE
CONTROL
THERMAL
PROTECTION
CURRENT
SENSING
AC IN
FG
FUSE
85
-
264V
OVER VOLTAGE
PROTECTION
External view
PBA/PBW
PB_E.indd 17 15.6.18 5:47:47 PM
PBA/PBW-18
MODEL
PBA600F-3R3
PBA600F-5
PBA600F-7R5
PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48
MAX OUTPUT WATTAGE[W] 396 600 600 636 645 648 648 624
DC OUTPUT
ACIN 100V
3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27A 36V 18A 48V 13A
ACIN 200V
*3
3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27(31)A 36V 18A 48V 13A
SPECIFICATIONS
MODEL
PBA600F-3R3
PBA600F-5
PBA600F-7R5
PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5)
CURRENT[A]
ACIN 100V
5.8typ 8.2typ
ACIN 200V
3typ 4.1typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
70typ 75typ 76typ 79typ 79typ 81typ 82typ 81typ
ACIN 200V
72typ 77typ 79typ 82typ 82typ 84typ 84typ 83typ
POWER FACTOR
ACIN 100V
0.98typ (Io=100%)
ACIN 200V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More than 3 sec. to re-start)
ACIN 200V
40/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More than 3 sec. to re-start)
LEAKAGE CURRENT[mA] 0.45/0.75max (ACIN 100V/240V 60Hz,Io=100%,According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]
ACIN 100V
120 120 80 53 43 27 18 13
ACIN 200V
*3
120 120 80 53 43 27(31)18 13
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]
0 to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-20 - 0C
*1
140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]
0 to +50C
*1
120max 120max 150max 150max 150max 150max 200max 200max
-20 - 0C
*1
160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
40max 50max 75max 120max 150max 240max 360max 480max
-20 to +50C
60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV]
*2
12max 20max 30max 48max 60max 96max 144max 192max
START-UP TIME[ms]
400typ(ACIN 100/200V,Io=100%)*Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms] 20typ (ACIN 100/200V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
*4
Vo+0.66 - 1.32
Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Provided
REMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 120X61X190mm [4.72X2.4X7.48 inches] (without terminal block and screw)(
WXHXD)/1.6kg max
COOLING METHOD Forced cooling (internal fan)
*7
*1Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3() means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage
protection circuit is please contact us for details.
*5 Derating is required.Consult us for details.
*6Please contact us about safety approvals for the model with option.
*7Please contact us about class C.
*A sound may occur from power supply at pulse loading.
PBA600F
AC-DC Power Supplies Enclosed Type
PB A 600 F -5 -O
Ordering information
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *6
C :with Coating
G:Low leakage current
U :Operation stop voltage
is set at a lower value
F1
:With Long-Life fan
F3
:Reverse air exhaust
type
F4
:Low speed fan
R
123456
PBA/PBW
PBA/PBW-18
Recommended EMI/EMC Filter
NAC-16-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
Refer to instruction manual
7.1.
(N)
(L) AC FG
AC
M5
LED
CN3
CN1
CN2
AC(N)
AC(L)
M4 Input terminal cover 4-M4
Mounting Hole
(Bottom side)
Output voltage
adjustable potentiometer
Output
terminal(+)
Output
terminal(-)
AIR FLOW
8-M4
Mounting Hole
(Both side)
Name plate
Name plate
Output terminal cover
¶ Tolerance : ±1 [±0.04]
¶ Weight : 1.6kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [ ]= inches
¶ Mounting torque : 1.2N · m(12.8kgf·cm)max
¶ Screw tightening torque : M4 1.6N • m(16.9kgf • cm)max
¶ The housing for the remote sensing unused is mounted on CN1
¶1 F1(Optional):190.5
61
17
10
(13.8)
[0.54]
[0.71] [0.98]
[7.48]
[5.91][0.94]
[0.94] [5.91]
[0.24]
[0.79]
[1.91]
[2.4]
[0.55]
[0.49] [1.5]
[0.55] [2.07]
[3.94]
[4.72]
[0.39]
[1.08]
[0.67]
[0.34]
[3.64]
[0.39][0.28] [0.24]
(18)
190 6max
¶1(F1:190.5)
120
24 150±0.5
24 150±0.5
12.5 38±0.5
25max
20max
8.7 (6)
7
14
14
27.5 (52.5)
(48.5)
(92.5)
10
100±0.5
FG(
)
¶ Please connect safety ground to FG terminal on the unit.
M5 2.5N • m(24.5kgf • cm)max
CN1
CN2
CN3
PBA/PBW
PBA/PBW-19
PBA600F
Block diagram
250V15A
INRUSH
CURRENT
LIMIT
RECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M
±S(REMOTE SENSING)
NOISE
FILTER
SWITCHING
DEVICE
CONTROL
RECTIFIER
AND
FILTER
RECTIFIER
AND
FILTER
VOLTAGE
SENSING
ACTIVE FILTER
VOLTAGE
SENSING CURRENT
SENSING
INVERTER
CONTROL
ALARMFAN
INTERNAL
REGULATOR
CONTROL
MASTER
SLAVE
CONTROL
THERMAL
PROTECTION
CURRENT
SENSING
AC IN
FG
FUSE
85
-
264V
OVER VOLTAGE
PROTECTION
External view
PBA/PBW
PB_E.indd 18 15.6.18 5:47:48 PM
PBA/PBW-19
MODEL
PBA600F-3R3
PBA600F-5
PBA600F-7R5
PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48
MAX OUTPUT WATTAGE[W] 396 600 600 636 645 648 648 624
DC OUTPUT
ACIN 100V
3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27A 36V 18A 48V 13A
ACIN 200V
*3
3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27(31)A 36V 18A 48V 13A
SPECIFICATIONS
MODEL
PBA600F-3R3
PBA600F-5
PBA600F-7R5
PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5)
CURRENT[A]
ACIN 100V
5.8typ 8.2typ
ACIN 200V
3typ 4.1typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
70typ 75typ 76typ 79typ 79typ 81typ 82typ 81typ
ACIN 200V
72typ 77typ 79typ 82typ 82typ 84typ 84typ 83typ
POWER FACTOR
ACIN 100V
0.98typ (Io=100%)
ACIN 200V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More than 3 sec. to re-start)
ACIN 200V
40/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More than 3 sec. to re-start)
LEAKAGE CURRENT[mA] 0.45/0.75max (ACIN 100V/240V 60Hz,Io=100%,According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]
ACIN 100V
120 120 80 53 43 27 18 13
ACIN 200V
*3
120 120 80 53 43 27(31)18 13
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]
0 to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-20 - 0C
*1
140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]
0 to +50C
*1
120max 120max 150max 150max 150max 150max 200max 200max
-20 - 0C
*1
160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
40max 50max 75max 120max 150max 240max 360max 480max
-20 to +50C
60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV]
*2
12max 20max 30max 48max 60max 96max 144max 192max
START-UP TIME[ms]
400typ(ACIN 100/200V,Io=100%)*Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms] 20typ (ACIN 100/200V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
*4
Vo+0.66 - 1.32
Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Provided
REMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 120X61X190mm [4.72X2.4X7.48 inches] (without terminal block and screw)(
WXHXD)/1.6kg max
COOLING METHOD Forced cooling (internal fan)
*7
R
(N)
(L) AC FG
AC
M5
LED
CN3
CN1
CN2
AC(N)
AC(L)
M4 Input terminal cover 4-M4
Mounting Hole
(Bottom side)
Output voltage
adjustable potentiometer
Output
terminal(+)
Output
terminal(-)
AIR FLOW
8-M4
Mounting Hole
(Both side)
Name plate
Name plate
Output terminal cover
¶ Tolerance : ±1 [±0.04]
¶ Weight : 1.6kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [ ]= inches
¶ Mounting torque : 1.2N · m(12.8kgf·cm)max
¶ Screw tightening torque : M4 1.6N • m(16.9kgf • cm)max
¶ The housing for the remote sensing unused is mounted on CN1
¶1 F1(Optional):190.5
61
17
10
(13.8)
[0.54]
[0.71] [0.98]
[7.48]
[5.91][0.94]
[0.94] [5.91]
[0.24]
[0.79]
[1.91]
[2.4]
[0.55]
[0.49] [1.5]
[0.55] [2.07]
[3.94]
[4.72]
[0.39]
[1.08]
[0.67]
[0.34]
[3.64]
[0.39][0.28] [0.24]
(18)
190 6max
¶1(F1:190.5)
120
24 150±0.5
24 150±0.5
12.5 38±0.5
25max
20max
8.7 (6)
7
14
14
27.5 (52.5)
(48.5)
(92.5)
10
100±0.5
FG(
)
¶ Please connect safety ground to FG terminal on the unit.
M5 2.5N • m(24.5kgf • cm)max
CN1
CN2
CN3
PBA/PBW
PBA/PBW-19
PBA600F
Block diagram
250V15A
INRUSH
CURRENT
LIMIT
RECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M
±S(REMOTE SENSING)
NOISE
FILTER
SWITCHING
DEVICE
CONTROL
RECTIFIER
AND
FILTER
RECTIFIER
AND
FILTER
VOLTAGE
SENSING
ACTIVE FILTER
VOLTAGE
SENSING CURRENT
SENSING
INVERTER
CONTROL
ALARMFAN
INTERNAL
REGULATOR
CONTROL
MASTER
SLAVE
CONTROL
THERMAL
PROTECTION
CURRENT
SENSING
AC IN
FG
FUSE
85
-
264V
OVER VOLTAGE
PROTECTION
External view
PBA/PBW
PB_E.indd 19 15.6.18 5:47:49 PM
PBA/PBW-20
MODEL
PBA1000F-3R3
PBA1000F-5
PBA1000F-7R5
PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48
MAX OUTPUT WATTAGE[W] 660 1000 1005 1056 1050 1056 1044 1056
DC OUTPUT
ACIN 100V
3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44A 36V 29A 48V 22A
ACIN 200V
*3
3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44(51)A 36V 29A 48V 22A
SPECIFICATIONS
MODEL
PBA1000F-3R3
PBA1000F-5
PBA1000F-7R5
PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5)
CURRENT[A]
ACIN 100V
9typ 13typ
ACIN 200V
5typ 7typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
74typ 79typ 80typ 82typ 82typ 84typ 84typ 84typ
ACIN 200V
76typ 81typ 83typ 84typ 84typ 86typ 86typ 86typ
POWER FACTOR
ACIN 100V
0.98typ (Io=100%)
ACIN 200V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More then 10 sec. to re-start)
ACIN 200V
40/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More then 10 sec. to re-start)
LEAKAGE CURRENT[mA] 0.5/1.0max (ACIN 100V/240V 60Hz,Io=100%,According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]
ACIN 100V
200 200 134 88 70 44 29 22
ACIN 200V
*3
200 200 134 88 70 44(51)29 22
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]
0 to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-20 - 0C
*1
140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]
0 to +50C
*1
120max 120max 150max 150max 150max 150max 200max 200max
-20 - 0C
*1
160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
40max 50max 75max 120max 150max 240max 360max 480max
-20 to +50C
60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV]
*2
12max 20max 30max 48max 60max 96max 144max 192max
START-UP TIME[ms]
400typ(ACIN 100/200V,Io=100%)*Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms] 20typ (ACIN 100/200V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
*4
Vo+0.66 - 1.32
Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Provided
REMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute,Cutoff current = 25mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 25mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 150X61X240mm [5.91X2.4X9.45 inches] (without terminal block and screw)(
WXHXD)/2.2kg max
COOLING METHOD Forced cooling (internal fan)
*7
*1Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within
150mm from the output terminal.
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3() means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage
protection circuit is please contact us for details.
*5 Derating is required.Consult us for details.
*6Please contact us about safety approvals for the model with option.
*7Please contact us about class C.
*A sound may occur from power supply at pulse loading.
PBA1000F
AC-DC Power Supplies Enclosed Type
PB A 1000 F -5 -O
Ordering information
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *6
C :with Coating
G:Low leakage current
U :Operation stop voltage
is set at a lower value
F1
:With Long-Life fan
F3
:Reverse air exhaust
type
F4
:Low speed fan
R
123456
PBA/PBW
PBA/PBW-20
Recommended EMI/EMC Filter
NAC-20-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
Refer to instruction manual
7.1.
CN1
CN3
CN2
AC(N)
AC(L)
M4
LED
8-M4
Mounting Hole
(Both side)
Name plate
Input terminal cover
Output voltage
adjustable potentiometer
Output terminal(+)
Output terminal(-)
¶ Tolerance : ±1 [±0.04]
¶ Weight : 2.2kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [ ]= inches
¶ Mounting torque : 1.2N • m(12.8kgf • cm)max
¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max
¶ The housing for the remote sensing unused is mounted on CN1
AIR FLOW
2-M4
2-º9
Name plate
AC
(L) FG
AC CN1
H
(N)
CN3
CN2
V.ADJ
Mounting Hole
(Bottom side)
4-M4
79
(18)
15.85
10
51.25
[2.02]
[0.39] [0.51][0.35]
[0.3]
[3.11]
[0.94] [4.12]
[4.33]
[5.91]
[2.4]
[1.5][0.45] [0.79]
[0.1]
[0.71]
[0.98]
[0.62] [0.98]
[1.14]
[1.38] [9.45] [0.24]
[6.5]
[1.14]
[0.51][0.28]
[6.5]
61
13
(25)
7
240 6max
150
25max
20
(35)
(7.5)
13 9
29 165±0.5
11.5 38±0.5
104.75
(24)
110±0.5
29 165±0.5
2.5
FG(
)
¶ Please connect safety ground to FG terminal on the unit.
[0.35]
PBA/PBW
PBA/PBW-21
PBA1000F
Block diagram
250V30A
INRUSH
CURRENT
LIMIT
RECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M
±S(REMOTE SENSING)
NOISE
FILTER
SWITCHING
DEVICE
CONTROL
RECTIFIER
AND
FILTER
RECTIFIER
AND
FILTER
VOLTAGE
SENSING
ACTIVE FILTER
VOLTAGE
SENSING CURRENT
SENSING
INVERTER
CONTROL
ALARMFAN
INTERNAL
REGULATOR
CONTROL
MASTER
SLAVE
CONTROL
THERMAL
PROTECTION
CURRENT
SENSING
AC IN
FG
FUSE
85
-
264V
OVER VOLTAGE
PROTECTION
External view
PBA/PBW
PB_E.indd 20 15.6.18 5:47:51 PM
PBA/PBW-21
MODEL
PBA1000F-3R3
PBA1000F-5
PBA1000F-7R5
PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48
MAX OUTPUT WATTAGE[W] 660 1000 1005 1056 1050 1056 1044 1056
DC OUTPUT
ACIN 100V
3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44A 36V 29A 48V 22A
ACIN 200V
*3
3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44(51)A 36V 29A 48V 22A
SPECIFICATIONS
MODEL
PBA1000F-3R3
PBA1000F-5
PBA1000F-7R5
PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5)
CURRENT[A]
ACIN 100V
9typ 13typ
ACIN 200V
5typ 7typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
74typ 79typ 80typ 82typ 82typ 84typ 84typ 84typ
ACIN 200V
76typ 81typ 83typ 84typ 84typ 86typ 86typ 86typ
POWER FACTOR
ACIN 100V
0.98typ (Io=100%)
ACIN 200V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More then 10 sec. to re-start)
ACIN 200V
40/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More then 10 sec. to re-start)
LEAKAGE CURRENT[mA] 0.5/1.0max (ACIN 100V/240V 60Hz,Io=100%,According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]
ACIN 100V
200 200 134 88 70 44 29 22
ACIN 200V
*3
200 200 134 88 70 44(51)29 22
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]
0 to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-20 - 0C
*1
140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]
0 to +50C
*1
120max 120max 150max 150max 150max 150max 200max 200max
-20 - 0C
*1
160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
40max 50max 75max 120max 150max 240max 360max 480max
-20 to +50C
60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV]
*2
12max 20max 30max 48max 60max 96max 144max 192max
START-UP TIME[ms]
400typ(ACIN 100/200V,Io=100%)*Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms] 20typ (ACIN 100/200V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
*4
Vo+0.66 - 1.32
Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Provided
REMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute,Cutoff current = 25mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 25mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 150X61X240mm [5.91X2.4X9.45 inches] (without terminal block and screw)(
WXHXD)/2.2kg max
COOLING METHOD Forced cooling (internal fan)
*7
R
CN1
CN3
CN2
AC(N)
AC(L)
M4
LED
8-M4
Mounting Hole
(Both side)
Name plate
Input terminal cover
Output voltage
adjustable potentiometer
Output terminal(+)
Output terminal(-)
¶ Tolerance : ±1 [±0.04]
¶ Weight : 2.2kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [ ]= inches
¶ Mounting torque : 1.2N • m(12.8kgf • cm)max
¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max
¶ The housing for the remote sensing unused is mounted on CN1
AIR FLOW
2-M4
2-º9
Name plate
AC
(L) FG
AC CN1
H
(N)
CN3
CN2
V.ADJ
Mounting Hole
(Bottom side)
4-M4
79
(18)
15.85
10
51.25
[2.02]
[0.39] [0.51][0.35]
[0.3]
[3.11]
[0.94] [4.12]
[4.33]
[5.91]
[2.4]
[1.5][0.45] [0.79]
[0.1]
[0.71]
[0.98]
[0.62] [0.98]
[1.14]
[1.38] [9.45] [0.24]
[6.5]
[1.14]
[0.51][0.28]
[6.5]
61
13
(25)
7
240 6max
150
25max
20
(35)
(7.5)
13 9
29 165±0.5
11.5 38±0.5
104.75
(24)
110±0.5
29 165±0.5
2.5
FG(
)
¶ Please connect safety ground to FG terminal on the unit.
[0.35]
PBA/PBW
PBA/PBW-21
PBA1000F
Block diagram
250V30A
INRUSH
CURRENT
LIMIT
RECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M
±S(REMOTE SENSING)
NOISE
FILTER
SWITCHING
DEVICE
CONTROL
RECTIFIER
AND
FILTER
RECTIFIER
AND
FILTER
VOLTAGE
SENSING
ACTIVE FILTER
VOLTAGE
SENSING CURRENT
SENSING
INVERTER
CONTROL
ALARMFAN
INTERNAL
REGULATOR
CONTROL
MASTER
SLAVE
CONTROL
THERMAL
PROTECTION
CURRENT
SENSING
AC IN
FG
FUSE
85
-
264V
OVER VOLTAGE
PROTECTION
External view
PBA/PBW
PB_E.indd 21 15.6.18 5:47:52 PM
PBA/PBW-22
MODEL
PBA1500F-3R3
PBA1500F-5
PBA1500F-7R5
PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48
MAX OUTPUT WATTAGE[W] 990 1500 1500 1500 1500 1680 1692 1680
DC OUTPUT
ACIN 100V
3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 65A 36V 42A 48V 32A
ACIN 200V
*3
3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 70(105)A 36V 47(70)A 48V 35A
SPECIFICATIONS
MODEL
PBA1500F-3R3
PBA1500F-5
PBA1500F-7R5
PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 7. option *5)
CURRENT[A]
ACIN 100V
15typ 19typ
ACIN 200V
8typ 10typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
72typ 77typ 81typ 81typ 83typ 84typ 84typ 84typ
ACIN 200V
75typ 81typ 83typ 84typ 86typ 87typ 87typ 87typ
POWER FACTOR
ACIN 100V
0.98typ (Io=100%)
ACIN 200V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More than 10 sec. to re-start)
ACIN 200V
40/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More than 10 sec. to re-start)
LEAKAGE CURRENT[mA] 0.9/1.5max (ACIN 100V/240V 60Hz,Io=100%,According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]
ACIN 100V
300 300 200 125 100 65 42 32
ACIN 200V
*3
300 300 200 125 100 70(105)47(70)35
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]
0 to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-20 - 0C
*1
140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]
0 to +50C
*1
120max 120max 150max 150max 150max 150max 200max 200max
-20 - 0C
*1
160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
40max 50max 75max 120max 150max 240max 360max 480max
-20 to +50C
60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV]
*2
12max 20max 30max 48max 60max 96max 144max 192max
START-UP TIME[ms] 600typ(ACIN 100/200V,Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 100/200V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
*4
Vo+0.66 - 1.32
Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Provided
REMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute,Cutoff current = 25mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 25mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE
Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B,additional EMI/EMC Filter required for meeting class B
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 178X61X268mm [7.01X2.4X10.55 inches] (without terminal block and screw)(
WXHXD)/3.4kg max
COOLING METHOD Forced cooling (internal fan)
*7
*1Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within
150mm from the output terminal.
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3() means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage
protection circuit is please contact us for details.
*5 Derating is required.Consult us for details.
*6Please contact us about safety approvals for the model with option.
*7Please contact us about class C.
*A sound may occur from power supply at pulse loading.
PBA1500F
AC-DC Power Supplies Enclosed Type
PB A 1500 F -5 -O
Ordering information
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *6
C :with Coating
G:Low leakage current
U :Operation stop voltage
is set at a lower value
F1
:With Long-Life fan
F3
:Reverse air exhaust
type
F4
:Low speed fan
R
123456
PBA/PBW
PBA/PBW-22
Recommended EMI/EMC Filter
NAC-20-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
Refer to instruction manual
7.1.
Name plate
(N)
V.ADJ
FGNC
AC
(L)
AC CN1
CN2
CN3
CN1
4-M4
2-º9
CN3
CN2
NC
AC(N)
AC(L)
¶ Tolerance : ±1 [±0.04]
¶ Weight : 3.4kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [ ]= inches
¶ Mounting torque : 1.2N • m(12.8kgf • cm)max
¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max
¶ The housing for the remote sensing unused is mounted on CN1
Output voltage
adjustable potentiometer
Name plate
AIR FLOW
8-M4
8-M4
Mounting Hole
(Both sides)
M4 Input terminal cover
Output terminal(+)
Output terminal(-)
LED
107
10 13 9 (7.5)
15.85
(25)(18)
15
10
4
(24) 132
171.5±0.5
19
152.4±0.5
268 6max
178
19 171.5±0.5
11.5 38±0.5
(45)
61
12.8
25max
51.25
FG(
)
¶ Please connect safety ground to FG terminal on the unit.
Mounting Hole
(Both sides)
[0.62]
[2.02]
[0.98]
[0.75]
[6.75]
[0.75]
[0.59][0.39]
[0.35]
[6.75]
[1.77] [0.24][10.55]
[4.21]
[5.2]
[6] [0.5]
[7.01]
[2.4]
[1.5][0.45]
[0.94]
[0.98]
[0.71]
[0.16]
[0.39]
[0.51][0.35]
[0.3]
PBA/PBW
PBA/PBW-23
PBA1500F
Block diagram
250V30A
INRUSH
CURRENT
LIMIT
RECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M
±S(REMOTE SENSING)
NOISE
FILTER
SWITCHING
DEVICE
CONTROL
RECTIFIER
AND
FILTER
RECTIFIER
AND
FILTER
VOLTAGE
SENSING
ACTIVE FILTER
VOLTAGE
SENSING CURRENT
SENSING
INVERTER
CONTROL
ALARMFAN
INTERNAL
REGULATOR
CONTROL
MASTER
SLAVE
CONTROL
THERMAL
PROTECTION
CURRENT
SENSING
AC IN
FG
FUSE
85
-
264V
OVER VOLTAGE
PROTECTION
External view
PBA/PBW
PB_E.indd 22 15.6.18 5:47:53 PM
PBA/PBW-23
MODEL
PBA1500F-3R3
PBA1500F-5
PBA1500F-7R5
PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48
MAX OUTPUT WATTAGE[W] 990 1500 1500 1500 1500 1680 1692 1680
DC OUTPUT
ACIN 100V
3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 65A 36V 42A 48V 32A
ACIN 200V
*3
3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 70(105)A 36V 47(70)A 48V 35A
SPECIFICATIONS
MODEL
PBA1500F-3R3
PBA1500F-5
PBA1500F-7R5
PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 7. option *5)
CURRENT[A]
ACIN 100V
15typ 19typ
ACIN 200V
8typ 10typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
72typ 77typ 81typ 81typ 83typ 84typ 84typ 84typ
ACIN 200V
75typ 81typ 83typ 84typ 86typ 87typ 87typ 87typ
POWER FACTOR
ACIN 100V
0.98typ (Io=100%)
ACIN 200V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More than 10 sec. to re-start)
ACIN 200V
40/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More than 10 sec. to re-start)
LEAKAGE CURRENT[mA] 0.9/1.5max (ACIN 100V/240V 60Hz,Io=100%,According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48
CURRENT[A]
ACIN 100V
300 300 200 125 100 65 42 32
ACIN 200V
*3
300 300 200 125 100 70(105)47(70)35
LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max
LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]
0 to +50C
*1
80max 80max 120max 120max 120max 120max 150max 150max
-20 - 0C
*1
140max 140max 160max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]
0 to +50C
*1
120max 120max 150max 150max 150max 150max 200max 200max
-20 - 0C
*1
160max 160max 180max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
40max 50max 75max 120max 150max 240max 360max 480max
-20 to +50C
60max 75max 120max 180max 180max 290max 440max 600max
DRIFT[mV]
*2
12max 20max 30max 48max 60max 96max 144max 192max
START-UP TIME[ms] 600typ(ACIN 100/200V,Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 100/200V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
*4
Vo+0.66 - 1.32
Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 Vo+4.8 - 12.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Provided
REMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute,Cutoff current = 25mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 25mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE
Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B,additional EMI/EMC Filter required for meeting class B
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 178X61X268mm [7.01X2.4X10.55 inches] (without terminal block and screw)(
WXHXD)/3.4kg max
COOLING METHOD Forced cooling (internal fan)
*7
R
Name plate
(N)
V.ADJ
FGNC
AC
(L)
AC CN1
CN2
CN3
CN1
4-M4
2-º9
CN3
CN2
NC
AC(N)
AC(L)
¶ Tolerance : ±1 [±0.04]
¶ Weight : 3.4kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [ ]= inches
¶ Mounting torque : 1.2N • m(12.8kgf • cm)max
¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max
¶ The housing for the remote sensing unused is mounted on CN1
Output voltage
adjustable potentiometer
Name plate
AIR FLOW
8-M4
8-M4
Mounting Hole
(Both sides)
M4 Input terminal cover
Output terminal(+)
Output terminal(-)
LED
107
10 13 9 (7.5)
15.85
(25)(18)
15
10
4
(24) 132
171.5±0.5
19
152.4±0.5
268 6max
178
19 171.5±0.5
11.5 38±0.5
(45)
61
12.8
25max
51.25
FG(
)
¶ Please connect safety ground to FG terminal on the unit.
Mounting Hole
(Both sides)
[0.62]
[2.02]
[0.98]
[0.75]
[6.75]
[0.75]
[0.59][0.39]
[0.35]
[6.75]
[1.77] [0.24][10.55]
[4.21]
[5.2]
[6] [0.5]
[7.01]
[2.4]
[1.5][0.45]
[0.94]
[0.98]
[0.71]
[0.16]
[0.39]
[0.51][0.35]
[0.3]
PBA/PBW
PBA/PBW-23
PBA1500F
Block diagram
250V30A
INRUSH
CURRENT
LIMIT
RECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M
±S(REMOTE SENSING)
NOISE
FILTER
SWITCHING
DEVICE
CONTROL
RECTIFIER
AND
FILTER
RECTIFIER
AND
FILTER
VOLTAGE
SENSING
ACTIVE FILTER
VOLTAGE
SENSING CURRENT
SENSING
INVERTER
CONTROL
ALARMFAN
INTERNAL
REGULATOR
CONTROL
MASTER
SLAVE
CONTROL
THERMAL
PROTECTION
CURRENT
SENSING
AC IN
FG
FUSE
85
-
264V
OVER VOLTAGE
PROTECTION
External view
PBA/PBW
PB_E.indd 23 15.6.18 5:47:54 PM
PBA/PBW-24
MODEL PBA1500T-5 PBA1500T-12 PBA1500T-24 PBA1500T-48
MAX OUTPUT WATTAGE[W] 1500 1500 1680 1680
DC OUTPUT
ACIN 200V
*3
5V 300A 12V 125A 24V 70(105)A 48V 35A
SPECIFICATIONS
MODEL PBA1500T-5 PBA1500T-12 PBA1500T-24 PBA1500T-48
INPUT
VOLTAGE[V] AC170 - 264 3f(AC100 Please refer to the instruction manual 7. option *5)
CURRENT[A]
ACIN 200V
6typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 200V
81typ 84typ 87typ 87typ
POWER FACTOR
ACIN 200V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 200V
40/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More than 10 sec. to re-start)
LEAKAGE CURRENT[mA] 1.5max (ACIN 240V 60Hz,Io=100%,According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 5 12 24 48
CURRENT[A]
ACIN 200V
*3
300 125 70(105) 35
LINE REGULATION[mV] 20max 48max 96max 192max
LOAD REGULATION[mV] 40max 100max 150max 300max
RIPPLE[mVp-p]
0 to +50C
*1
80max 120max 120max 150max
-20 - 0C
*1
140max 160max 160max 400max
RIPPLE NOISE[mVp-p]
0 to +50C
*1
120max 150max 150max 200max
-20 - 0C
*1
160max 180max 180max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
50max 120max 240max 480max
-20 to +50C
75max 180max 290max 600max
DRIFT[mV]
*2
20max 48max 96max 192max
START-UP TIME[ms]
300typ(ACIN 200V,Io=100%) *Start-up time is 500ms typ for less than 1 minute of applying input again from turning off the input voltage .
HOLD-UP TIME[ms] 20typ (ACIN 200V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
3.96 - 6.00 8.25 - 13.20 16.50 - 26.40 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V]
5.00 - 5.15 12.00 - 12.48 24.00 - 24.96 48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
*4
Vo+1.0 - 2.0 Vo+2.4 - 4.8 Vo+4.8 - 9.6 Vo+2.0 - 12.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Provided
REMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute,Cutoff current = 25mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 25mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE
Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B,additional EMI/EMC Filter required for meeting class B
OTHERS CASE SIZE/WEIGHT 178X61X268mm [7.01X2.4X10.55 inches] (without terminal block and screw)(
WXHXD)/3.4kg max
COOLING METHOD Forced cooling (internal fan)
*1Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within
150mm from the output terminal.
*2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3() means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage
protection circuit is please contact us for details.
*5 Derating is required.Consult us for details.
*6Please contact us about safety approvals for the model with option.
*A sound may occur from power supply at pulse loading.
PBA1500T
AC-DC Power Supplies Enclosed Type
PB A 1500 T -5 -O
Ordering information
1Series name
2Single output
3Output wattage
4Triple input phase
5Output voltage
6Optional *6
C :with Coating
G:Low leakage current
U :Operation stop voltage
is set at a lower value
F1
:With Long-Life fan
F3
:Reverse air exhaust
type
F4
:Low speed fan
R
123456
PBA/PBW
PBA/PBW-24
Recommended EMI/EMC Filter
TAC-10-683
Refer to instruction manual
7.1.
Name plate
(L2)
V.ADJ
FG(L3)
AC
(L1)
CN1
CN2
CN3
CN1
4-M4
2-º9
CN3
CN2
AC(L3)
AC(L2)
AC(L1)
¶ Tolerance : ±1 [±0.04]
¶ Weight : 3.4kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [ ]= inches
¶ Mounting torque : 1.2N • m(12.8kgf • cm)max
¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max
¶ The housing for the remote sensing unused is mounted on CN1
Output voltage
adjustable potentiometer
Name plate
AIR FLOW
8-M4
8-M4
Mounting Hole
(Both sides)
M4 Input terminal cover
Output terminal(+)
Output terminal(-)
LED
107
10 13 9 (7.5)
15.85
(25)(18)
15
10
4
(24) 132
171.5±0.5
19
152.4±0.5
268 6max
178
19 171.5±0.5
11.5 38±0.5
(45)
61
12.8
25max
51.25
FG(
)
¶ Please connect safety ground to unit in M4 holes.
Mounting Hole
(Both sides)
[0.62]
[2.02]
[4.21]
[0.39]
[0.51][0.35]
[0.3]
[0.98]
[0.75]
[6.75]
[1.77] [0.24][10.55]
[5.2]
[6] [0.5]
[7.01]
[0.94]
[0.16]
[0.75]
[0.59][0.39]
[0.35]
[6.75]
[2.4]
[1.5][0.45]
[0.98]
[0.71]
PBA/PBW
PBA/PBW-25
PBA1500T
Block diagram
AC250V16A
INRUSH
CURRENT
LIMIT
RECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M(MONITOR)
±S(REMOTE SENSING)
NOISE
FILTER
SWITCHING
DEVICE
CONTROL
RECTIFIER
AND
FILTER
RECTIFIER
AND
FILTER
VOLTAGE
SENSING
ACTIVE FILTER
VOLTAGE
SENSING CURRENT
SENSING
INVERTER
CONTROL
ALARMFAN
OPEN
PHASE
INTERNAL
REGULATOR
CONTROL
MASTER
SLAVE
CONTROL
THERMAL
PROTECTION
CURRENT
SENSING
AC IN
(3º)
FG
FUSE
170
-
264V
OVER VOLTAGE
PROTECTION
External view
PBA/PBW
PB_E.indd 24 15.6.18 5:47:56 PM
PBA/PBW-25
MODEL PBA1500T-5 PBA1500T-12 PBA1500T-24 PBA1500T-48
MAX OUTPUT WATTAGE[W] 1500 1500 1680 1680
DC OUTPUT
ACIN 200V
*3
5V 300A 12V 125A 24V 70(105)A 48V 35A
SPECIFICATIONS
MODEL PBA1500T-5 PBA1500T-12 PBA1500T-24 PBA1500T-48
INPUT
VOLTAGE[V] AC170 - 264 3f(AC100 Please refer to the instruction manual 7. option *5)
CURRENT[A]
ACIN 200V
6typ
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 200V
81typ 84typ 87typ 87typ
POWER FACTOR
ACIN 200V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 200V
40/40typ (Io=100%)(
Primary inrush current /Secondary inrush current)(
More than 10 sec. to re-start)
LEAKAGE CURRENT[mA] 1.5max (ACIN 240V 60Hz,Io=100%,According to IEC60950-1,DENAN)
OUTPUT
VOLTAGE[V] 5 12 24 48
CURRENT[A]
ACIN 200V
*3
300 125 70(105) 35
LINE REGULATION[mV] 20max 48max 96max 192max
LOAD REGULATION[mV] 40max 100max 150max 300max
RIPPLE[mVp-p]
0 to +50C
*1
80max 120max 120max 150max
-20 - 0C
*1
140max 160max 160max 400max
RIPPLE NOISE[mVp-p]
0 to +50C
*1
120max 150max 150max 200max
-20 - 0C
*1
160max 180max 180max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
50max 120max 240max 480max
-20 to +50C
75max 180max 290max 600max
DRIFT[mV]
*2
20max 48max 96max 192max
START-UP TIME[ms]
300typ(ACIN 200V,Io=100%) *Start-up time is 500ms typ for less than 1 minute of applying input again from turning off the input voltage .
HOLD-UP TIME[ms] 20typ (ACIN 200V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
3.96 - 6.00 8.25 - 13.20 16.50 - 26.40 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V]
5.00 - 5.15 12.00 - 12.48 24.00 - 24.96 48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
*4
Vo+1.0 - 2.0 Vo+2.4 - 4.8 Vo+4.8 - 9.6 Vo+2.0 - 12.0
OPERATING INDICATION LED (Green)
REMOTE SENSING Provided
REMOTE ON/OFF Provided
ISOLATION
INPUT-OUTPUT-RC AC3,000V 1minute,Cutoff current = 25mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 25mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-AUX AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +71C(Required Derating), 20 - 90%RH (Non condensing)3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing)9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS (At only AC input)
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN50178 Complies with DEN-AN
CONDUCTED NOISE
Complies with FCC Part15 classB,VCCI-B,CISPR22-B,EN55011-B,EN55022-B,additional EMI/EMC Filter required for meeting class B
OTHERS CASE SIZE/WEIGHT 178X61X268mm [7.01X2.4X10.55 inches] (without terminal block and screw)(
WXHXD)/3.4kg max
COOLING METHOD Forced cooling (internal fan)
R
Name plate
(L2)
V.ADJ
FG(L3)
AC
(L1)
CN1
CN2
CN3
CN1
4-M4
2-º9
CN3
CN2
AC(L3)
AC(L2)
AC(L1)
¶ Tolerance : ±1 [±0.04]
¶ Weight : 3.4kg max
¶ PCB Material/thickness : FR-4 / 1.6mm [0.06]
¶ Chassis material : Aluminum
¶ Dimensions in mm, [ ]= inches
¶ Mounting torque : 1.2N • m(12.8kgf • cm)max
¶ Screw tightening torque : 1.6N • m(16.9kgf • cm)max
¶ The housing for the remote sensing unused is mounted on CN1
Output voltage
adjustable potentiometer
Name plate
AIR FLOW
8-M4
8-M4
Mounting Hole
(Both sides)
M4 Input terminal cover
Output terminal(+)
Output terminal(-)
LED
107
10 13 9 (7.5)
15.85
(25)(18)
15
10
4
(24) 132
171.5±0.5
19
152.4±0.5
268 6max
178
19 171.5±0.5
11.5 38±0.5
(45)
61
12.8
25max
51.25
FG(
)
¶ Please connect safety ground to unit in M4 holes.
Mounting Hole
(Both sides)
[0.62]
[2.02]
[4.21]
[0.39]
[0.51][0.35]
[0.3]
[0.98]
[0.75]
[6.75]
[1.77] [0.24][10.55]
[5.2]
[6] [0.5]
[7.01]
[0.94]
[0.16]
[0.75]
[0.59][0.39]
[0.35]
[6.75]
[2.4]
[1.5][0.45]
[0.98]
[0.71]
PBA/PBW
PBA/PBW-25
PBA1500T
Block diagram
AC250V16A
INRUSH
CURRENT
LIMIT
RECTIFIER
DC OUT
RC(REMOTE ON / OFF)
VB(VOLTAGE BALANCE)
CB(CURRENT BALANCE)
PG(POWER GOOD)
AUX(12V 0.1A)
±M(MONITOR)
±S(REMOTE SENSING)
NOISE
FILTER
SWITCHING
DEVICE
CONTROL
RECTIFIER
AND
FILTER
RECTIFIER
AND
FILTER
VOLTAGE
SENSING
ACTIVE FILTER
VOLTAGE
SENSING CURRENT
SENSING
INVERTER
CONTROL
ALARMFAN
OPEN
PHASE
INTERNAL
REGULATOR
CONTROL
MASTER
SLAVE
CONTROL
THERMAL
PROTECTION
CURRENT
SENSING
AC IN
(3º)
FG
FUSE
170
-
264V
OVER VOLTAGE
PROTECTION
External view
PBA/PBW
PB_E.indd 25 15.6.18 5:47:56 PM
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Cosel:
PBA1000F-5-GU PBA1000F-5-U PBA1000F-7R5 PBA1000F-7R5-C PBA1000F-7R5-CF3 PBA1000F-7R5-CF4
PBA1000F-7R5-F1 PBA1000F-7R5-F3 PBA1000F-7R5-F4 PBA1000F-7R5-G PBA1000F-7R5-U PBA1500F-12
PBA1500F-12-C PBA1500F-12-CF3 PBA1500F-12-CF4 PBA1500F-12-D9 PBA1500F-12-F1 PBA1500F-12-F3
PBA1500F-12-F4 PBA1500F-12-G PBA1500F-12-U PBA1500F-15 PBA1500F-15-C PBA1500F-15-CF3 PBA1500F-
15-CF4 PBA1500F-15-F1 PBA1500F-15-F3 PBA1500F-15-F4 PBA1500F-15-G PBA1500F-15-U PBA1500F-24
PBA1500F-24-C PBA1500F-24-CF1 PBA1000F-5-G PBA1000F-5-F4 PBA1000F-5-F3 PBA1000F-5-F1 PBA1000F-
5-CF4 PBA1000F-5-CF3 PBA1000F-5-CF1 PBA1000F-5-C PBA1000F-5 PBA1000F-48-UF4 PBA1000F-48-UF1
PBA1000F-48-U PBA1000F-48-GU PBA1000F-48-G PBA1000F-48-F4 PBA1000F-48-F3 PBA1000F-48-F1
PBA1000F-48-D42 PBA1000F-48-CF4 PBA1000F-48-CF3 PBA1000F-48-C PBA1000F-48 PBA1000F-3R3-U
PBA1000F-3R3-G PBA1000F-3R3-F4 PBA1000F-3R3-F3 PBA1000F-3R3-F1 PBA1000F-3R3-CF4 PBA1000F-3R3-
CF3 PBA1000F-3R3-CF1 PBA1000F-3R3-C PBA1000F-3R3 PBA1000F-36-U PBA1000F-36-G PBA1000F-36-F4
PBA1000F-36-F3 PBA1000F-36-F1 PBA1000F-36-D28 PBA1000F-36-CF4 PBA1000F-36-CF3 PBA1000F-36-CF1
PBA1000F-36-C PBA1000F-36 PBA1000F-24-UF4 PBA1000F-24-UF3 PBA1000F-24-UF1 PBA1000F-24-U
PBA1000F-24-G PBA1000F-24-F4 PBA1000F-24-F3 PBA1000F-24-F1 PBA1000F-24-D18 PBA1000F-24-CF4
PBA1000F-24-CF3 PBA1000F-24-CF1 PBA1000F-24-C PBA1000F-24 PBA1000F-15-U PBA1000F-15-G
PBA1000F-15-F4 PBA1000F-15-F3 PBA1000F-15-F1 PBA1000F-15-CU PBA1000F-15-CF4 PBA1000F-15-CF3
PBA1000F-15-C PBA1000F-15