971-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
SWS300A-600 Series
Features
u Lower Cost
u Active Power Factor Correction
u Universal Input (85 - 265VAC)
u Input Transient Protected IEC61000-4
u Enclosed
u Global safety Approvals
u Level B EMI
Single Output General Purpose Power Supplies
Model SWS300A SWS600
Input Voltage range (1) - 85 - 265VAC (47 - 63Hz) or 120 - 370VDC
Inrush Current (115 / 230VAC) A 20 / 40
Power Factor - Meets EN61000-3-2
Input Current (100/200VAC) A 3.6 / 1.8A 7.2 / 3.6A
Temperature Coeffi cient - <0.02%/°C
Overcurrent Protection - >105%, Constant current style
Overvoltage Protection V Yes, cycle AC to reset
Overtemperature Protection - Yes, cycle AC to reset
Hold Up Time (Typ) ms 20ms at 115/230VAC
Leakage Current (max) mA SWS300: 0.75mA , SWS600: 1.5mA
Remote Sense - None Yes
Parallel Connection - None Yes
Remote On/Off - None Yes
AC Fail Signal - None Yes, open collector output
LED Indicator - Green LED = On
Operating Temperature °C -10 to +65°C (See table for derating - model specifi c)
Storage Temperature °C -30 to +85°C
Humidity (non condensing) - 30 - 90% RH operating, 10 - 95%RH non operating
Storage Humidity (non condensing) - 10 - 95% RH
Cooling - Internal fan
Withstand Voltage - I/P to Grnd 2kVAC, I/P to O/P 3kVAC, O/P to Grnd 500VAC, O/P to CNT 100VAC for 1 min
Isolation Resistance - >100M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating) - 10 - 55Hz (sweep for 1 min)19.6m/s2 constant X, Y, Z 1 hour each plane)
Immunity - EN61000-4-2, -3, -4, -5, -6, -8, -11
Safety Agency Approvals - UL60950, CSA60950, EN60950, EN50178, CE Mark
Conducted & Radiated EMI - EN55011 / EN55022-B, FCC Class B
Recommended EMI Filter - RSAL2006 RSAN2010
Weight (Typ) g 950 2000
Size (WxHxD) in 2.05 x 4.01 x 7.8” 3.62 x 4.72 x 7.48”
Warranty yrs Two Years
(1) Derate linearly to 85% load from 115VAC to 85VAC input (derate to 90% load for SWS600-3 & -5)
Specifi cations
Key Market Segments & Applications