Embedded Power for
Business-Critical Continuity
Ordering Information
MMooddeell
NNuummbbeerr
OOuuttppuutt
VVoollttaaggee
MMiinniimmuumm
LLooaadd
MMaaxxiimmuumm LLooaadd wwiitthh
CCoonnvveeccttiioonn CCoooolliinngg
MMaaxxiimmuumm LLooaadd
wwiitthh 3300CCFFMM
ffoorrcceedd AAiirrPPeeaakk LLooaadd 11RReegguullaattiioonn 22
RRiippppllee PP//PP
((PPAARRDD))33
LPS41(-T) 3.3V 0A 8A 11A 12A ±2% 50 mV
LPS42(-T) 5V 0A 8A 11A 12A ±2% 50 mV
LPS43(-T) 12V 0A 3.3A 4.5A 5A ±2% 120 mV
LPS44(-T) 15V 0A 2.6A 3.6A 4A ±2% 150mV
LPS45(-T) 24V 0A 1.7A 2.3A 2.5A ±2% 240mV
LPS48(-T) 48V 0A 0.9A 1.2A 1.3A ±2% 480 mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and
load ranges.
4. (-T) indicates Terminal Block option for input and output (instead of Molex type)
Rev. 02.05.07
LPS40 Series
2of 3
Operating temperature: 0° to 50°C ambient. Derate each output 2.5% per degree from
50° to 70°C, -20°C start up.
Storage temperature: -40°C to +85°C
Temperature coefficient: ±0.4% per °C
Electromagnetic
susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing 5% to 95% RH
Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at
four major resonances 0.75G peak 5Hz to 500Hz, operational
MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions
Environmental Specifications