ACDC
Specification
150500 Watts
•Single Output Industrial Supplies
•High Efficiency
•Low Cost
•150 W Convection Cooled
•300 W & 500 W with Internal Fans
•Outputs from 12 V to 48 V
•3 Year Warranty
LCL Series
Input
Input Voltage • 85-264 VAC (127-370 VDC) (see note 1)
Input Frequency • 47-63 Hz
Input Current • 2.1 A max for LCL150, 4.5 A max for
LCL300, 6.6 A max for LCL500
Inrush Current • 40 A max for LCL150,
60 A max for LCL300 & 500
cold start at 25 °C, 230 VAC
Power Factor • >0.9
Earth Leakage Current • <2 mA at 264 VAC, 60 Hz
Input Protection • LCL150: T3.15 A/250 V,
LCL300: T6.3A/250 V,
LCL500: T10A/250 V,
internal fuse fitted in line
Output
Output Voltage • See tables
Output Voltage Trim • See tables
Initial Set Accuracy • ±100 mV at 50% load
Minimum Load • None required
Start Up Delay • 2 s max for LCL150, 1.5 s max for LCL300,
0.8 s max for LCL500
Start Up Rise Time • 50 ms max for LCL150,
35 ms max for LCL300 & LCL500
Hold Up Time • 10 ms min at 115 VAC and full load
Line Regulation • ±0.5% max for LCL150,
±0.3% for LCL300 & LCL500
Load Regulation • ±1% max
Transient Response • 4% max deviation recovery to within 1%
in 500 µs for a 50% load change
Ripple & Noise • See tables
Overvoltage Protection • 110-140%, recycle input to reset
Overtemperature • Output turns off when OTP triggered,
Protection measured internally, auto recovery
Overload Protection • 110-150% of rated output power. Delayed
by 1 s min to allow for peak loads.
Short Circuit Protection • Trip and restart (hiccup mode),
auto recovery
Remote Sense • Fitted to LCL500 only, compensates for
0.25 V max each line
Remote On/Off • Fitted on LCL500 only,
On = logic low or open circuit,
Off = logic high
xppower.com
General
Efficiency • 88% typical at full load & 230 VAC
Isolation • 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Switching Frequency • 90-110 kHz main converter & 45-190 kHz
PFC for LCL150, 80-190 kHz main converter
& 62-65 kHz PFC for LCL300 & 500
Power Density • 2.7 W/in3LCL150, 4.4 W/in3LCL300,
4.9 W/in3LCL500
MTBF • LCL150: >489 kHrs,
LCL300: >235 kHrs,
LCL500: >211 kHrs to MIL-HBK-217F at
25 °C, GB
Environmental
Operating Temperature • -10 °C to +70 °C, derate from 100% load
at 50 °C to 50% load at 70 °C
Cooling • LCL150 convection cooled, LCL300 &
LCL500 have internal fans
Operating Humidity • 5% to 90% non condensing
Storage Temperature • -40 °C to +85 °C
Operating Altitude • 3000 m
Vibration • 10-500 Hz, 2 g, 10 mins per cycle on
3 axes
EMC & Safety
Emissions • EN55022 level B conducted,
level A radiated
Harmonic Currents • EN61000-3-2 class A
LCL150: EN61000-3-2 class C for loads ≥40%
LCL300 & LCL500: EN61000-3-2 class C
for loads ≥20%
Voltage Flicker • EN61000-3-3
ESD Immunity • EN61000-4-2, ±4 kV contact,
±8 kV air discharge, Performance Criteria A
Radiated Immunity • EN61000-4-3, level 2 Perf Criteria A
EFT/Burst • EN61000-4-4, level 2 Perf Criteria A
Surge • EN61000-4-5,
installation class 3, Perf Criteria A
Conducted Immunity • EN61000-4-6, level 2 Perf Criteria A
Magnetic Field • EN61000-4-8, 1 A/m Perf Criteria A
Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals • EN60950-1, UL60950-1, CSA60950
No 22.2