Under development New product GH04125A2A Blue violet Laser Diode High Power Blue violet Laser Diode Outline Dimensions Features Unitmm (1) Wavelength : 406 nm(Typ.) 0.40.1 X 902 10.15 (2) Optical power output : (3) 5.6mm CAN package 2 CW 125mW Y 0.40.1 Applications emission point 5.6+0 -0.025 (1) 406nm band light source C 0.1MAX. (3) other application 0.250.03 4.4MAX. (2) Laser sensor 3.550.1 1.0MIN. 2 Optical power output(CW) Reverse voltage Laser Photo diode Ratings unit Po 150 mW Vrl 2 V Vrd 30 V Topc(c) -10 +70 Storage temperature Tstg -40 +85 Soldering temperature Tsld Operatings temperature(case temp.) 3 Symbol 1 Tc : Case temperature 2 CW :Continuous Wave Operation reference plane 0.6MIN. 1.670.08 1.2MAX. 3-0.450.1 , [ Terminal connection ] Stem 350 Soldering position is 1.6mm apart from bottom edge of the case. (Immersion time: 3s) ) 0.1MA Parameter 1 0.5MIN. 0.5MAX. (Tc=25 6.50.5 Absolute Maximum Ratings 1.20.1 2.70.5 Z Photo diode Laser diode Notice In the absence of confirmation by device specification sheets. SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. Specifications are subject to change without notice for improvement. As of July, 2008 ET-080804 Specifications Symbol Conditions MIN. Threshold current Ith - - Operating current Iop - Operating voltage Vop - 5.4 6.4 V p 400 406 413 nm 6 9.5 12 Parameter Wavelength Half intensity angle 3 4 Misalignment angle 4 Parallel Perpendicular Po=125mW Parallel Perpendicular Differential efficiency d 115mW I(125mW)-I(10mW) Monitor Photo diode current Im Po=125mW, Vrd=5V TYP. MAX. unit 35 50 mA 125 155 mA 16 19 24.5 -2.5 - 2.5 -3.0 - 3.0 0.9 1.3 - mW/mA 0.1 0.3 0.5 mA Tc : Case temperature Initial value, Continuous Wave Operation. Initial value is measured by the standard Laser tester of the sharp possession. Angle of 50% peak intensity.(Full angle at half-maximum) Paralel to the junction plane.(X-Z plane) Perpendicular to the junction plane.(Y-Z plane) Notice In the absence of confirmation by device specification sheets. SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. Specifications are subject to change without notice for improvement. As of July, 2008 ET-080804 Forward voltage - Forward current Optical power output - Forward current 7 6 Forward voltage VF (V) Optical power output Po (mW) 150 100 Condition CW -10 0 25 50 70 50 5 4 Condition CW 3 -10 0 25 50 70 2 1 0 0 0 50 100 150 200 0 250 50 100 150 200 250 Forward current IF (mA) Forward current IF (mA) Case temperature dependence of threshold current(Ith) Case temperature dependence of operating current(Iop) 2.0 2.0 Relative operating current Relative threshold current Po=125mW(CW) 1.5 1.0 0.5 1.5 1.0 0.5 The value of Tc=25 is 1.0 The value of Tc=25 is 1.0 0.0 0.0 -20 0 20 40 60 80 -20 0 Case temperature Tc ( ) 20 40 60 80 Case temperature Tc ( ) Case temperature dependence of operating voltage(Vop) Case temperature dependence of monitor PD current(Im) 2.0 1.50 Po=125mW(CW) Relative monitor PD current Relative operating voltage Po=125mW(CW) 1.5 1.0 0.5 1.25 1.00 0.75 The value of Tc=25 is 1.0 The value of Tc=25 is 1.0 0.50 0.0 -20 0 20 40 Case temperature Tc ( ) 60 80 20 30 40 50 60 70 Case Temperature Tc ( ) Note) Characteristics shown in diagrams are typical values.(not assurance value) As of July, 2008 ET-080804 80 Case temperature dependence of wavelength Optical power dependence of Lasing spectrum 416 Relative optical power output Wavelength p (nm) Tc=25 Po=125mW(CW) 414 412 410 408 406 404 402 125mW 50mW 10mW 1mW 400 20 30 40 50 60 70 80 Case Temperature Tc ( ) 402 403 404 405 406 407 408 Wavelength p (nm) Far field pattern (FFP) Relative optical power output (Tc=25, Po=125mW) -40 -30 -20 // -10 0 10 20 30 40 Angle () Note) Characteristics shown in diagrams are typical values.(not assurance value) As of July, 2008 ET-080804 CAUTION 1. These technical sheets include materials protected under the copyright of Sharp Corporation ("Sharp"). Please do not reproduce or cause anyone to reproduce them without Sharp's consent. 2. When using this product, please observe the absolute maximum ratings and the instructions for use outlined in these technical sheets, as well as the precautions mentioned below. Sharp assumes no responsibility for any damage resulting from use of the product which does not comply with the absolute maximum ratings and the instructions included in these technical sheets, and the precautions mentioned below. (Precautions) (1) This products is designed for use in the following application areas; * OA equipment * Audio visual equipment * Home appliance * Telecommunication equipment (Terminal) * Measuring equipment * Tooling machines * Computers If the use of the product in the above application areas is for equipment listed in paragraphs (2) or (3), please be sure to observe the precautions given in those respective paragraphs. (2) Appropriate measures, such as fail-safe design and redundant design considering the safety design of the overall system and equipment, should be taken to ensure reliability and safety when this product is used for equipment which demands high reliability and safety in function and precision, such as ; * Transportation control and safety equipment (aircraft, train, automobile etc.) * Traffic signals * Gas leakage sensor breakers * Rescue and security equipment * Other safety equipment (3) Please do not use this product for equipment which require extremely high reliability and safety in function and precision, such as ; * Space equipment * Telecommunication equipment (for trunk lines) * Nuclear power control equipment * Medical equipment (4) Please contact and consult with a Sharp sales representative if there are any questions regarding interpretation of the above three paragraphs. 3. Please contact and consult with a Sharp sales representative for any questions about this product. Notice In the absence of confirmation by device specification sheets. SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. Specifications are subject to change without notice for improvement. As of July, 2008 ET-080804