FULL-SIZE DIP 32.768kHz CRYSTAL CLOCK OSCILLATOR ACOW Pb ESD Sensitive RoHS/RoHS II compliant 20.2 x 12.6 x 8.0 mm Moisture Sensitivity Level (MSL) - Through-hole part, MSL doesn't apply. FEATURES: * RoHS compliant * 32.768 kHz APPLICATIONS: * Computers, Modems, Microprocessors * Communication, Test equipment * CMOS/TTL output * Tri-state function STANDARD SPECIFICATIONS: Parameters Minimum +70 +125 +100 5.25 Units kHz C C ppm V 15 mA 60 % @ 1/2Vdd Rise and Fall Time (Tr/Tf) 250 ns Output Load 5 15 LS TTL pF V V @ 10% to 90% of output waveform Frequency Operating Temperature Storage Temperature Overall Frequency Stability Supply Voltage (Vdd) 0 -55 -100 4.75 Typical 32.768 5.0 Input Current Symmetry 40 Output Voltage Tri-state Function (Option A) VOH VOL 0.9*Vdd VIH 0.7*Vdd Maximum 0.1*Vdd V VIL 0.3*Vdd V Notes See options See options "1" or Open: Oscillation "0": Output disable (Hi Z) OPTIONS & PART IDENTIFICATION: (Left blank if standard) Table (1) ACOW-32.768kHz- Tri-state A: Tri-state on pin 1 Codes Pin form G: Gull Wing QXX for trimmed leads * (*) Note: see table 1 Q45 Q40 Q35 Q30 Q25 Q20 Q15 Q10 Trimmed Length (inch(mm)) 0.45 (11.43) 0.40 (10.16) 0.35 (8.89) 0.30 (7.62) 0.25 (6.35) 0.20 (5.08) 0.15 (3.81) 0.10 (2.54) Note: Use appropriate code numbers for other trimmed lengths not listed. (Ex: Q14 for 0.14 inch (3.55 mm)) ABRACON IS ISO9001:2008 CERTIFIED LLC 2 Faraday, Suite# B | Irvine | CA 92618 Revised:04.01.15 Ph. 949.546.8000 | Fax. 949.546.8001 Visit www.abracon.com for Terms and Conditions of Sale FULL-SIZE DIP 32.768kHz CRYSTAL CLOCK OSCILLATOR ACOW Pb ESD Sensitive RoHS/RoHS II compliant 20.2 x 12.6 x 8.0 mm STANDARD SPECIFICATIONS: PIN 1 7 8 14 FUNCTION NC or E/D Tri -state GND/Case Output Vdd Dimensions: inches (mm) Packaging 25pcs /tube ATTENTION: Abracon Corporation's products are COTS - Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications. Abracon's products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment, written consent and authorization from Abracon Corporation is required. Please contact Abracon Corporation for more information. ABRACON IS ISO9001:2008 CERTIFIED LLC 2 Faraday, Suite# B | Irvine | CA 92618 Revised:04.01.15 Ph. 949.546.8000 | Fax. 949.546.8001 Visit www.abracon.com for Terms and Conditions of Sale Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: ABRACON: ACOW-32.768KHZ-A