Magnecraft Time Delay and Sensor Relays TM Catalog 2011 Contents MagnecraftTM Time Delay and Sensor Relays Series Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 820 Series Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 831 Series Voltage Sensing Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 841 Series Current Sensing Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 800 Series Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 TDR782 Series Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 TDR782 Series Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 TDRPRO Series Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 TDRSOX/SRX Series Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 TDRPRO/SOX/SRX Series Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Website Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 2 MagnecraftTM Time Delay and Sensor Relays Series Overview Magnecraft time delay and sensor relays are designed to provide cost effective solutions for your industrial timing and sensing needs. Available in a wide array of forms, fits and functions, Magnecraft timers offer the ultimate in flexibility and performance. Accurate adjustments, legible wiring diagrams and an interactive timer demo make selection quick and easy. Key Features Multiple timing functions Wide voltage range from 12 to 240 V Single timing range or from 100 ms to 10 days DIN or Panel mounting styles Conforms to international standards including UL, CSA, RoHS and CE Series Style 820 Relays Time delay relay DIN mount Rated Contact Timing Current Configuration Range Load (A) Number of Functions Function Type Input Voltage Range Page SPST 15 100 ms to 10 days 10 All 12 to 240 Vac/Vdc 4 DPDT 831 Voltage Sensing Relays Voltage Sensing DIN mount relay SPDT 15 100 ms to 10 sec 1 On Delay 120 Vac; 240 Vac 7 841 Current Sensing Relays Current sensing DIN mount relay SPDT 15 100 ms to 10 sec 1 On Delay 24 to 240 Vac 10 DPDT 5 TDR782 Relays Time delay relay Plug-in w/ Dial 100 ms to 10 hrs 1 On Delay 12, 24 Vdc; 24, 110, 230 Vac 14 10 All 12 to 240 Vac/Vdc 22 4PDT TDRPRO Relays Time delay relay Plug-in w/ 5 Digit Thumbwheel 3 SPDT 12 100 ms to 10 hrs DPDT 3 On Delay / Repeat Cycle / On Interval TDRSOX Relays Time delay relay Plug-in w/ Dial & DIP switches DPDT 12 100 ms to 10 hrs 2 On Delay Interval 12 to 120 Vac/Vdc; 240 Vac 25 TDRSRX Relays Time delay relay Plug-in w/ Dial & DIP switches DPDT 12 100 ms to 10 hrs 2 12 to 120 Off Delay Vac/Vdc; Retriggerable one shot 240 Vac 25 3 MagnecraftTM Time Delay and Sensor Relays Description 820 Series SPDT, 15 A; DPDT, 15 A Description The 820 Series Time Delay Relays are 35 mm DIN rail mountable products offering 10 different timing functions, ultra-wide timing range (10 ms to 10 days) and a universal voltage input (12-240 Vac/Vdc), all in a slim 17.5 mm (0.69 in) modular package. 822 Relay 821 Relay Input Voltage Functions Available (1) Feature Benefit Up to 10 functions 5 timing functions controlled via supply voltage 4 timing functions controlled via trigger input 1 function of memory latching Meets most timing requirements Contact configuration SPDT or DPDT Universal power supply 12 to 240 Vac/Vdc 2 LED status indicators Shows status at a glance Only 17.5 mm (0.69 in) wide Ideal for tight spaces DIN rail mountable Easy installation / Screwdriver required RoHS complaint Environmentally friendly Timing Range Contact Configuration Rated Current (A) Standard Part Number 12-240 Vac/Vdc A,B,C,D,E,F,G,H,I,J 10 ms - 10 days SPDT 15 821TD10H-UNI 12-240 Vac/Vdc A,B,C,D,E,F,G,H,I,J 10 ms - 10 days DPDT 15 822TD10H-UNI (1) For function descriptions, see pages 33 and 34. Part Number Explanation Series: 821 = SPDT 822 = DPDT Relay Style: TD = Time Delay 4 Input Voltage: UNI = 12 to 240 Vac/Vdc Number of Functions: 10H = 10 Functions MagnecraftTM Time Delay and Sensor Relays Specifications 820 Series SPDT, 15 A; DPDT, 15 A Specifications Part Number 821TD10H-UNI 822TD10H-UNI Input Voltage Range 12-240 Vac / Vdc 12-240 Vac / Vdc Operating Voltage (% of Nominal) 85% - 110% 85% - 110% Maximum Power Consumption 3 VA 1.7 W 3 VA 1.7 W Contact Configuration SPDT DPDT Output Current Rating 15 A 15 A Contact Material Silver Alloy Silver Alloy Switching Capability 15 A @ 240 Vac, 50/60 Hz, 24 Vdc 1/2 HP @ 120 Vac 1 HP @ 240 Vac Pilot Duty B300 15 A @ 240 Vac, 50/60 Hz, 24 Vdc 1/2 HP @ 120 Vac 1 HP @ 240 Vac Pilot Duty B300 Minimum Switching Requirement 100 mA 100 mA Functions Available (1) All All Time Scales 8 8 Time Ranges 100 ms to 1 sec 1 sec to 10 sec 0.1 min to 1 min 1 min to 10 min 1 hr to 10 hrs 0.1 hr to 1 hrs 1 day to 10 day 0.1 day to 1 day 100 ms to 1 sec 1 sec to 10 sec 0.1 min to 1 min 1 min to 10 min 1 hr to 10 hrs 0.1 hr to 1 hrs 1 day to 10 day 0.1 day to 1 day Tolerance 5% of Mechanical setting 5% of Mechanical setting Repeatability @ constant voltage and temperature 0.2% 0.2% Reset Time 150 ms maximum 150 ms maximum Trigger Pulse Length 50 ms minimum 50 ms minimum Electrical Life (operations at rated current) (2) 100,000 operations 100,000 operations Mechanical Life (Unpowered) (2) 10,000,000 operations 10,000,000 operations Dielectric Strength (Input to Contacts) 2500 Vac 2500 Vac Dielectric Strength (Between Open Contacts) 1000 Vac 1000 Vac Storage Temperature Range -30C (-22F) to +70C (+158F) -30C (-22F) to +70C (+158F) Operating Temperature Range -20C (-4F) to +55C (+131F) -20C (-4F) to +55C (+131F) Terminal Wire Capacity (Input and Output) 14 AWG (2.1 mm) maximum 14 AWG (2.1 mm) maximum Terminal Screw Torque 7.1 lb-in (0.8 N*m) maximum 7.1 lb-in (0.8 N*m) maximum Weight 65 g (2.29 oz) 65 g (2.29 oz) Input Indication Green LED Green LED Output Indication (Blinks = Timing or On = Energized) Red LED Red LED Enclosure Rating (according to IEC 60529 IP rating) IP20 IP20 Approvals cULus (file no. E234203), CE 61810-1, RoHS cULus (file no. E234203), CE 61810-1, RoHS Input Characteristics Output Characteristics Timing Characteristics General Characteristics (1) For function descriptions, see pages 33 and 34. (2) Actual product life will vary based on electrical load, duty cycle, application, and environmental conditions. 5 MagnecraftTM Time Delay and Sensor Relays Dimensions, Wiring Diagram 820 Series SPDT, 15 A; DPDT, 15 A Dimensions -- inches (millimeters) 1.35 (34.2) 0.63 (16) 3.5 (90) 2.6 (65) 0.7 (17.6) 0.6 (14.2) 0.13 (3.4) 0.2 (5) 1.8 (45.3) 1.4 (35) 0.7 (16.71) 2.7 (67.5) 0.3 (7.4) 0.236 (6) 0.6 (16) 1.3 (34) Wiring Diagram INPUT VOLTAGE + Un - A1 S A2 INPUT VOLTAGE EXTERNAL CONTROL SWITCH (DRY SWITCH ONLY) + Un - A1 S A2 R 25 26 28 R 15 16 18 821TD10H-UNI 6 R 15 16 18 822TD10H-UNI 15 - COMMON 16 - NORMALLY CLOSED 18 - NORMALLY OPEN 25 - COMMON 26 - NORMALLY CLOSED 28 - NORMALLY OPEN Description MagnecraftTM Time Delay and Sensor Relays 831 Series SPDT, 15 A Description Voltage sensing relay featuring a single phase AC voltage sensor capable of monitoring and reacting to over and under voltage conditions; all in a modular, FingersafeTM (according to IEC 60529 IP rating) package. 831 Relay Feature Benefit 3-state indication LEDs Indicates normal state and 2 types of faulted states Umax dial Used to set the upper trip-point for the voltage sensor Voltage Umin Used to set the upper trip-point as % of Umax Timing dial Adjustable delay 0-10 sec DIN mountable Mounts directly on DIN rail Nominal Input Voltage Sensing Voltage Range Timing Range Contact Configuration Rated Current (A) Standard Part Number 120 Vac Upper: 80 to 150 Vac Lower: 30 to 99% of upper 0 sec - 10 sec SPDT 15 831VS-120A 240 Vac Upper: 160 to 276 Vac Lower: 30 to 99% of upper 0 sec - 10 sec SPDT 15 831VS-240A Part Number Explanation Series: 831 = SPDT Relay Style: VS = Voltage Sensor Nominal Input Voltage: 120A = 120 Vac 240A = 240 Vac 7 MagnecraftTM Time Delay and Sensor Relays Specifications 831 Series SPDT, 15 A Specifications Part Number 831VS-120A 831VS-240A Nominal Input Voltage 120 Vac 240 Vac Absolute Input Voltage Maximum 200 Vac 280 Vac Maximum Power Consumption 1.2 VA 1.2 VA Contact Configuration SPDT SPDT Output Current Rating 15 A 15 A Contact Material Silver Alloy Silver Alloy Switching Capability 15A @ 240 Vac, 50/60 Hz, 24 Vdc 1/2 HP @ 120 Vac 1 HP @ 240 Vac Pilot Duty B300 15A @ 240 Vac, 50/60 Hz, 24 Vdc 1/2 HP @ 120 Vac 1 HP @ 240 Vac Pilot Duty B300 Minimum Switching Requirement 100 mA at 5 Vac or Vdc 100 mA at 5 Vac or Vdc Time Scales 1 1 Time Ranges 0 sec to 10 sec 0 sec to 10 sec Tolerance 5% of Mechanical setting 5% of Mechanical setting Repeatability @ constant voltage and temperature 1% 1% Upper Sensing Voltage Range 80 - 150 Vac 160 - 276 Vac Lower Sensing Voltage Range 30 to 99% of upper preset 30 to 99% of upper preset Electrical Life (operations at rated current) (1) 100,000 operations 100,000 operations Mechanical Life (Unpowered) (1) 10,000,000 operations 10,000,000 operations Dielectric Strength (Input to Contacts) 2500 Vac 2500 Vac Dielectric Strength (Between Open Contacts) 1000 Vac 1000 Vac Storage Temperature Range -30C (-22F) to +70C (+158F) -30C (-22F) to +70C (+158F) Operating Temperature Range -20C (-4F) to +55C (+131F) -20C (-4F) to +55C (+131F) Terminal Wire Capacity (Input and Output) 14 AWG (2.1 mm) maximum 14 AWG (2.1 mm) maximum Terminal Screw Torque 7.1 Lb-in (0.8 N*m) maximum 7.1 Lb-in (0.8 N*m) maximum Weight 71 g (2.50 oz) 71 g (2.50 oz) Input Indication Green LED Green LED Output Indication (Blinks = Timing or On = Energized) Red LED Red LED Enclosure Rating (according to IEC 60529 IP rating) IP20 IP20 Approvals cULus (File No. E234203), CE 61810-1, RoHS cULus (File No. E234203), CE 61810-1, RoHS Input Characteristics Output Characteristics Timing/Sensing Characteristics General Characteristics (1) Actual product life will vary based on electrical load, duty cycle, application, and environmental conditions. 8 MagnecraftTM Time Delay and Sensor Relays Dimensions, Wiring Diagram 831 Series SPDT, 15 A Dimensions -- inches (millimeters) 1.35 (34.2) 0.63 (16) 2.6 (65) 0.7 (17.6) 0.6 (14.2) 0.13 (3.4) 0.2 (5) 3.5 (90) 1.8 (45.3) 1.4 (35) 2.7 (67.5) 0.3 (7.4) 0.236 (6) 0.6 (16) Wiring Diagram INPUT VOLTAGE Un + - A1 A2 15 16 15 - COMMON 16 - NORMALLY CLOSED 18 - NORMALLY OPEN 18 9 Description MagnecraftTM Time Delay and Sensor Relays 841 Series SPDT, 15 A Description Current sensing relay which allows the user to monitor the current of one circuit (1 to 8 A) and switch another circuit in case of an over current or under current condition; all in a modular, FingersafeTM (according to IEC 60529 IP rating) package. 841 Relay Feature Benefit Current sensing adjustment knob Sense anywhere from 10% to 100% of the rated sensing current Input/ouput terminals Accepts up to a 14 AWG Wire Solid state circuitry Used for sensing and timing control Input/output indication Shows status at a glance DIN rail mountable Mounts directly on a DIN Rail Only 17.5 mm (0.69 in) wide Ideal for tight spaces Wide input range Enabled to work with common AC voltages. Input Voltage Sensing Current Range Timing Range Contact Configuration Rated Current (A) Standard Part Number 24 to 240 Vac 100 mA to 1 A 100 ms to 10 sec SPDT 15A 841CS1-UNI 24 to 240 Vac 200 mA to 2 A 100 ms to 10 sec SPDT 15A 841CS2-UNI 24 to 240 Vac 500 mA to 5 A 100 ms to 10 sec SPDT 15A 841CS5-UNI 24 to 240 Vac 800 mA to 8 A 100 ms to 10 sec SPDT 15A 841CS8-UNI Part Number Explanation Series: 841 = SPDT Relay Style: CS = Current Sensor 10 Sensing Range: 1 = 100 mA to 1 A 2 = 200 mA to 2 A 5 = 500 mA to 5 A 8 = 800 mA to 8 A Nominal Input Voltage: UNI = 24 to 240 Vac MagnecraftTM Time Delay and Sensor Relays Specifications 841 Series SPDT, 15 A Specifications Part Number 841CS1-UNI 841CS2-UNI 841CS5-UNI 841CS8-UNI Input Characteristics Input Voltage Range 24 to 240 Vac 24 to 240 Vac 24 to 240 Vac 24 to 240 Vac Maximum Power Consumption 1.2 VA 1.2 VA 1.2 VA 1.2 VA Output Characteristics Contact Configuration SPDT SPDT SPDT SPDT Output Current Rating 15 A 15 A 15 A 15 A Contact Material Silver Alloy Silver Alloy Silver Alloy Silver Alloy Switching Voltage 15A @ 240 Vac, 50/60 Hz, 24 Vdc 1/2 HP @ 120 Vac 1 HP @ 240 Vac Pilot Duty B300 15A @ 240 Vac, 50/60 Hz, 24 Vdc 1/2 HP @ 120 Vac 1 HP @ 240 Vac Pilot Duty B300 15A @ 240 Vac, 50/60 Hz, 24 Vdc 1/2 HP @ 120 Vac 1 HP @ 240 Vac Pilot Duty B300 15A @ 240 Vac, 50/60 Hz, 24 Vdc 1/2 HP @ 120 Vac 1 HP @ 240 Vac Pilot Duty B300 Minimum Switching Requirement 100 mA at 5 Vac or Vdc 100 mA at 5 Vac or Vdc 100 mA at 5 Vac or Vdc 100 mA at 5 Vac or Vdc Timing/Sensing Characteristics Time Scales 1 1 1 1 Time Ranges 0 sec to 10 sec 0 sec to 10 sec 0 sec to 10 sec 0 sec to 10 sec Tolerance 5% of Mechanical setting 5% of Mechanical setting 5% of Mechanical setting 5% of Mechanical setting Repeatability @ constant voltage and temperature 1% 1% 1% 1% Sensing Range 100 mA to 1 A 200 mA to 2 A 500 mA to 5 A 800 mA to 8 A General Characteristics Electrical Life (operations at rated current) (1) 100,000 operations 100,000 operations 100,000 operations 100,000 operations Mechanical Life (Unpowered) (1) 10,000,000 operations 10,000,000 operations 10,000,000 operations 10,000,000 operations Dielectric Strength (Input to Contacts) 2500 Vac 2500 Vac 2500 Vac 2500 Vac Dielectric Strength (Between Open Contacts) 1000 Vac 1000 Vac 1000 Vac 1000 Vac Storage Temperature Range -30C (-22F) to +70C (+158F) -30C (-22F) to +70C (+158F) -30C (-22F) to +70C (+158F) -30C (-22F) to +70C (+158F) Operating Temperature Range -20C (-4F) to +55C (+131F) -20C (-4F) to +55C (+131F) -20C (-4F) to +55C (+131F) -20C (-4F) to +55C (+131F) Terminal Wire Capacity (Input and Output) 14 AWG (2.1 mm) maximum 14 AWG (2.1 mm) maximum 14 AWG (2.1 mm) maximum 14 AWG (2.1 mm) maximum Terminal Screw Torque 7.1 Lb-in (0.8 N*m) maximum 7.1 Lb-in (0.8 N*m) maximum 7.1 Lb-in (0.8 N*m) maximum 7.1 Lb-in (0.8 N*m) maximum Weight 60 g (2.12 oz) 60 g (2.12 oz) 60 g (2.12 oz) 60 g (2.12 oz) Input Indication Green LED Green LED Green LED Green LED Output Indication (Blinks = Timing or On = Energized) Red LED Red LED Red LED Red LED Enclosure Rating (according to IEC 60529 IP rating) IP20 IP20 IP20 IP20 Approvals cULus (File No. E234203), CE 61810-1, RoHS cULus (File No. E234203), CE 61810-1, RoHS cULus (File No. E234203), CE 61810-1, RoHS cULus (File No. E234203), CE 61810-1, RoHS (1) Actual product life will vary based on electrical load, duty cycle, application, and environmental conditions. 11 MagnecraftTM Time Delay and Sensor Relays Dimensions, Wiring Diagram 841 Series SPDT, 15 A Dimensions -- inches (millimeters) 1.35 (34.2) 0.63 (16) 3.5 (90) 2.6 (65) 0.7 (17.6) 0.6 (14.2) 0.13 (3.4) 0.2 (5) 1.8 (45.3) 1.4 (35) 2.7 (67.5) 0.3 (7.4) 0.6 (16) 0.236 (6) Wiring Diagram Wiring for direct current sensing: Wiring for current sensing through current transformer: Input Voltage Input Voltage SENSING CIRCUIT A1 B1 A2 Ip INPUT VOLTAGE Is A1 B1 A2 15 - COMMON 16 - NORMALLY CLOSED 18 - NORMALLY OPEN 15 12 16 18 current transformer Ip: prima ry current Is: secondary current 15 16 18 MagnecraftTM Time Delay and Sensor Relays Accessories 800 Series Accessories DIN Rail, 16-700DIN; Panel Adapter, 16-788C1 Description The 16-700DIN DIN Rail provides quick removable and installations of most sockets and the 16-788C1 panel adapter provides a panel mounting option. 16-700DIN DIN Rail 16-788C1 Panel Adapter Shown with 841 Relay Shown with 822 Relay Description Function For Use With Relays Packaging Minimum Standard Part Number Metal DIN Rail Quick installation and removable 821, 822, 831, 841 10 16-700DIN Panel Adapter Provides additional panel mount option. 821, 822, 831, 841 10 16-788C1 Dimensions -- inches (millimeters) 16-700DIN Metal DIN Rail 39.3 (1000) 0.3 (7.5 +0.0/-0.4) 1.377 +0.011/-0.007 (35 0.3) 1.0 (25.5) 0.19 (5) NOTES: 1. THE LIPS AT BASE OF DIN RAIL MAY OR MAY NOT BE PRESENT ON DIN RAIL EXTRUSIONS. 0.39 (10) 0.99 (25) SEE NOTE 1 0.039 (1 0.04) 16-788C1 Panel Mount Adapter 0.06 TYP (1.4) 0.17 TYP (4.31) 0.256 (6.5) 0.12 (3.04) 1.39 MAX (35.3) 0.165 (4.19) 0.165 TYP (4.19) 1.7 (43.18) 0.585 (14.95) 1.4 MAX (35.5) 13 Description MagnecraftTM Time Delay and Sensor Relays TDR782 Series DPDT, 5 A; 4PDT, 3 A Description Miniature time delay relay that is single-function, single-voltage and socketcompatible. Ideal for tight spaces. Feature Benefit Time setting Select between 7 different time scales Socket compatible Mounts directly to DIN Rail or Panel Excellent immunity to interference Conforms to IEC 61812-1 / A11 Input/Output indication Shows status at a glance Time adjustment dial Fine tune the time setting IEC and NEMA Universal Socket Compatibility TDR782 Relay Input Voltage Functions Available (1) Timing Range Contact Configuration Rated Current (A) Standard Part Number 110 Vac A (On Delay) 100 ms to 100 hrs DPDT 5A TDR782XBXA-110A 24 Vac A (On Delay) 100 ms to 100 hrs DPDT 5A TDR782XBXA-24A 24 Vdc A (On Delay) 100 ms to 100 hrs DPDT 5A TDR782XBXA-24D 110 Vac A (On Delay) 100 ms to 100 hrs 4PDT 3A TDR782XDXA-110A 12 Vdc A (On Delay) 100 ms to 100 hrs 4PDT 3A TDR782XDXA-12D 230 Vac A (On Delay) 100 ms to 100 hrs 4PDT 3A TDR782XDXA-230A 24 Vac A (On Delay) 100 ms to 100 hrs 4PDT 3A TDR782XDXA-24A 24 Vdc A (On Delay) 100 ms to 100 hrs 4PDT 3A TDR782XDXA-24D (1) For function descriptions, see pages 33 and 34. Part Number Explanation Series: TDR782 = 782 Miniature Timer &RQWDFW&RQJXUDWLRQ XBX = DPDT XDX = 4PDT 14 )XQFWLRQV A = On Delay ,QSXWVROWDJH 12D = 12 Vdc 24D = 24 Vdc 24A = 24 Vac 110A = 110 Vac 230A = 230 Vac MagnecraftTM Time Delay and Sensor Relays Specifications TDR782 Series DPDT, 5 A; 4PDT, 3 A Specifications Part Number TDR782XBX TDR782XDX Input Voltage Range 24, 120, 230 Vac 12, 24 Vdc 24, 120, 230 Vac 12, 24 Vdc Operating Voltage (Vac) 85% to 115% of Nominal 85% to 115% of Nominal Operating Voltage (Vdc) 90% to 110% of Nominal 90% to 110% of Nominal Maximum Power Consumption 1.7 VA @ 24 Vac 2.6 VA @ 120 Vac 3 VA @ 230 Vac 1.5 W @ 12 Vdc 1.2 W @ 24 Vdc 1.7 VA @ 24 Vac 2.6 VA @ 120 Vac 3 VA @ 230 Vac 1.5 W @ 12 Vdc 1.2 W @ 24 Vdc Contact Configuration DPDT 4PDT Output Current Rating 5A 3A Contact Material Silver Alloy Silver Alloy Maximum inrush current 10A @ < 100 ms 10A @ < 100 ms Minimum Switching Requirement 100 mA at 5 Vac or Vdc 100 mA at 5 Vac or Vdc Functions Available (1) A (On Delay) A (On Delay) Time Scales 7 7 Time Ranges 100 ms to 1 sec 1 sec to 10 sec 0.1 min to 1 min 1 min to 10 min 0.1 hr to 1 hr 1 hr to 10 hrs 10 hr to 100 hrs 100 ms to 1 sec 1 sec to 10 sec 0.1 min to 1 min 1 min to 10 min 0.1 hr to 1 hr 1 hr to 10 hrs 10 hr to 100 hrs Tolerance 5% of Mechanical setting 5% of Mechanical setting Repeatability @ constant voltage and temperature 0.5% 0.5% Reset Time 50 ms maximum 50 ms maximum Temperature Drift 0.05 % / C 0.05 % / C Electrical Life (operations at rated current) (2) 100,000 operations 100,000 operations Mechanical Life (Unpowered) (2) 10,000,000 operations 10,000,000 operations Dielectric Strength (Input to Contacts) 2000 Vrms 2000 Vrms Storage Temperature Range -40C (-40F) to +70C (+158F) -40C (-40F) to +70C (+158F) Operating Temperature Range -20C (-4F) to +60C (+140F) -20C (-4F) to +60C (+140F) Weight 43 g (1.52 oz) 43 g (1.52 oz) Input Indication Green LED Green LED Output Indication (On = Energized) Amber LED Amber LED Enclosure Rating (according to IEC 60529 IP rating) IP50 IP50 Approvals cURus (File No. E191122), CSA (File No. 254373), CE 61810-1, RoHS cURus (File No. E191122), CSA (File No. 254373), CE 61810-1, RoHS Input Characteristics Output Characteristics Timing Characteristics General Characteristics (1) For function descriptions, see pages 33 and 34. (2) Actual product life will vary based on electrical load, duty cycle, application, and environmental conditions. 15 MagnecraftTM Time Delay and Sensor Relays Dimensions, Wiring Diagram TDR782 Series DPDT, 5 A; 4PDT, 3 A Dimensions -- inches (millimeters) 0.14 (3.5) 0.8 (21) 2.57 (65.28) 0.02 (0.48) 1.0 (27) 2.3 (59.4) Wiring Diagram 1 4 1 2 3 4 5 8 5 6 7 8 9 12 9 10 11 12 13 14 13 SPDT NEMA 16 14 DPDT NEMA MagnecraftTM Time Delay and Sensor Relays Description TDR782 Series Accessories Socket 70-782EL8, 70-782-EL14-1, 70-782E14-1, 70-782D14-1 Spring Clip 16-TDR782SC Description The TDR782 accessories create a complete system solution for all your application needs. The 70-782EL socket offers an alternate installation option for plug-in models. The 16-TDR782SC retention clip holds the relay securely in place while allowing quick and efficient installation and maintenance. 70-782EL8-1 Socket 70-782EL14-1 Socket 16-TDR782SC Spring Clip Relay Accessories Description Function For Use With Relays Packaging Minimum Standard Part Number Socket Mounts directly to DIN Rail or Panel TDR782XBX 10 70-782EL8-1 Socket Mounts directly to DIN Rail or Panel TDR782XDX 10 70-782EL14-1 Socket DIN/Panel Mount with Rising Elevator Box Terminals TDR782XDX 10 70-782E14-1 Socket DIN/Panel Mount with Screw Terminals & Clamping Plates TDR782XDX 10 70-782D14-1 Socket DIN/Panel Mount with Screw Terminals & Clamping Plates TDR782XDX 10 70-461-1 Socket Solder Terminals for Chassis mount TDR782XDX 10 70-378-1 Socket Printed Circuit Terminals TDR782XDX 10 70-379-1 Socket Accessories Description Function Coil Voltage For Use With Relays Packaging Minimum Standard Part Number Metal Holding Clip Helps secure relay in socket - TDR782 10 16-TDR782SC Metal DIN Rail Quick installation and removable of sockets - TDR782 10 16-700DIN Write-On Plastic Labels Allows for identification of circuits in mult-relay applications - TDR782 10 16-782FT-1 17 MagnecraftTM Time Delay and Sensor Relays Specifications TDR782 Series Accessories Socket 70-782EL8, 70-782-EL14-1, 70-782E14-1, 70-782D14-1 Spring Clip 16-TDR782SC Specifications Part Number 70-782EL8-1, 70-782EL14-1 70-782EL14-1 70-782E14-1 Contact Configuration DPDT 4PDT 4PDT Number of Terminals 8 14 14 Mounting Style Panel/DIN Rail Panel/DIN Rail Panel/DIN Rail Current Rating 12 A 10 A 10 A Nominal Voltage Rating 300 V 300 V 300 V Storage temperature Range -40C (-40F) to +105C (+221F) -40C (-40F) to +105C (+221F) -40C (-40F) to +105C (+221F) Protection Category (FingersafeTM) IP 20 IP 20 IP 20 Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Steel, Zinc Plated Steel, Zinc Plated Screw Style Combination Head Combination Head Combination Head Screw Size M3 M3 M3 Terminal Connection Elevator Elevator Elevator Terminal Layout Logic Logic Logic Wire Size Capacity Solid Cu 14 / 16 (2) AWG, 2.5 / 1.5 (2) mm Stranded Cu 14 / 16 (2) AWG, 2.5 / 1.5 (2) mm Solid Cu 14 / 16 (2) AWG, 2.5 / 1.5 (2) mm Stranded Cu 14 / 16 (2) AWG, 2.5 / 1.5 (2) mm Solid Cu 14 / 16 (2) AWG, 2.5 / 1.5 (2) mm Stranded Cu 14 / 16 (2) AWG, 2.5 / 1.5 (2) mm DIN Rail Mounting, EN 60715 35 mm (1.38 in) 35 mm (1.38 in) 35 mm (1.38 in) Maximum Screw Torque 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) Flammability Rating 94V-0 Class 94V-0 Class 94V-0 Class Body Color Light Gray Light Gray Light Gray DIN Locking Method Red Plastic Locking Clip Red Plastic Locking Clip Metal Compression Spring Product Certifications cURus (File No. E70550), CSA (File No. 40787), CE 60947-1, RoHS cURus (File No. E70550), CSA (File No. 40787), CE 60947-1, RoHS cURus (File No. E70550), CSA (File No. 40787), CE 60947-1, RoHS Part Number 70-379-1 70-378-1 70-461-1, 70-782D14-1 Contact Configuration 4PDT 4PDT 4PDT Number of Terminals 14 14 14 Mounting Style PCB Chassis Panel/DIN Rail Current Rating 5A 5A 10A Nominal Voltage Rating 300 V 300 V 300 V Storage temperature Range -40C (-40F) to +105C (+221F) -40C (-40F) to +105C (+221F) -40C (-40F) to +105C (+221F) Protection Category (FingersafeTM) - - IP 20 (for 70-782D14-1) Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Steel, Zinc Plated Screw Style - - Combination Head Screw Size - - M3 mm Terminal Connection PCB Solder Screw Clamping Terminal Layout Non Logic Non Logic Non-Logic Wire Size Capacity - Solid Cu 14 / 16 (2) AWG, 2.5 / 1.5 (2) mm Stranded Cu 14 / 16 (2) AWG, 2.5 / 1.5 (2) mm Solid Cu 14 / 16 (2) AWG, 2.5 / 1.5 (2) mm Stranded Cu 14 / 16 (2) AWG, 2.5 / 1.5 (2) mm DIN Rail Mounting, EN 60715 - - 35 mm (1.38 in) Maximum Screw Torque - - 7 lb-in (0.8 N*m) Flammability Rating 94V-0 Class 94V-0 Class 94V-0 Class Body Color Light Gray Light Gray Light Gray DIN Locking Method - - Red Plastic Locking Clip Product Certifications cURus (File No. E70550), CSA (File No. 97899), CE 60947-1, RoHS cURus (File No. E70550), CSA (File No. 97899), CE 60947-1, RoHS 70-461-1: cURus (File No. E70550), CSA (File No. 97899), CE 60947-1, RoHS 70-782D14-1: cURus (File No. E70550), CSA (File No. 40787), CE 60947-1, RoHS 18 MagnecraftTM Time Delay and Sensor Relays Dimensions TDR782 Series Accessories Socket 70-782EL8, 70-782-EL14-1, 70-782E14-1, 70-782D14-1 Spring Clip 16-TDR782SC Dimensions -- inches (millimeters) 70-782EL8-1: Mounts directly to DIN Rail or Panel 70-782EL14-1 Mounts directly to DIN Rail or Panel 2.4 (61.0) 1.06 (26.9) 0.9 (22) 0.74 (19.0) 3.34 (85.0) 0.2 (5.6) 2.4 (61.0) 0.74 (19.0) 41 11 41 31 21 12 44 9 14 12 11 10 9 44 34 24 14 8 5 42 12 4 1 3.34 (85.0) A2 IEC: NEMA: 14 70-782E14-1 DIN/Panel Mount with Rising Elevator Box Terminals 7 6 5 32 22 12 4 3 2 1 0.67 (17.0) INPUT 1.49 (38.0) A1 A2 A1 NEMA: 14 INPUT 13 13 1.57 (40.0) 1.0 (25.5) 0.14 (3.8) 0.74 (19.0) 44 34 24 14 34 7 24 6 8 7 6 5 44 14 42 32 22 12 4 3 2 1 3.11 (79.0) 0.12 (3.0) A1 A2 INPUT 2.4 (61.0) 3.3 (84.0) IEC: NEMA: 14 IEC: 70-782D14-1 DIN/Panel Mount with Screw Terminals and Clamping Plates 0.86 (22.0) 1.06 (26.9) 1.57 (40.0) 8 3.11 (79.0) 1.49 (38.0) 3.12 (79.0) 11 42 0.2 (5.6) 3.11 (79.0) 1.69 (43.0) 0.9 (22) 1.06 (25.4) 8 5 42 32 22 12 4 3 2 1 1.55 (39.5) 0.14 (3.8) 11 A2 A1 INPUT INPUT 14 13 41 31 21 11 12 11 10 9 13 41 31 21 12 11 10 0.82 (21.0) 1.18 (30.0) 9 0.25 (6.4) 19 MagnecraftTM Time Delay and Sensor Relays Dimensions (continued) TDR782 Series Accessories Socket 70-782EL8, 70-782-EL14-1, 70-782E14-1, 70-782D14-1 Spring Clip 16-TDR782SC Dimensions -- inches (millimeters) 70-378-1 Solder Terminals for Chassis Mount 70-461-1 DIN/Panel Mount with Screw Terminals and Clamping Plates 0.708 (18) 0.44 (11.1) 0.86 (21.8) 0.375 (9.52) 6 5 1 0.105 (2.67) 0.10 (2.54) 2 7 3 8 4 2.51 (64.0) 1.14 (28.5) 2.71 (69.0) 1.25 (32.0) 1 3 1 4 1 2 1.0 (25.4) 1 1 1 0 0.17 (4.32) DIA. TYP. 0.015 (0.381) 1.01 (25.7) RECOMMENDED CHASSIS CUTOUT TOP VIEW 0.75 (19.0) 0.105 (2.66) 0.015 (0.381) 0.1875 (4.76) 0.674 (17.0) 0.06 (1.52) 0.625 (15.8) 0.07 DIA. (1.77) 20 0.16 (4.06) 0.25 (6.35) 0.25 (6.35) 0.095 (2.4) 14 PLACES 0.102 (2.6) 0.16 DIA. (4.06) 0.30 (7.82) GROUND LUG 0.08 (2.03) 0.44 (11.1) 0.061 (1.54) 0.525 (13.3) 0.145 (3.68) DIA. 0.07 (1.78) DIA. 1.0 (25.4) 0.15 (3.81) 0.375 (9.5) 0.12 (3.04) 0.10 (2.5) RECOMMENDED CIRCUIT BOARD LAYOUT TOP VIEW 0.44 (11.1) 0.05 (1.27) GROUND LUG 0.375 (9.52) 0.102 (2.59) 70-379-1 Printed Circuit Terminals 0.375 (9.52) 0.05 (1.27) 0.16 (4.06) 0.89 (22.7) 1.2 (30.7) 0.35 (8.89) 0.175 (4.44) 0.16 DIA. (4.06) 0.078 (1.98) 0.86 (21.5) 0.44 (11.17) 0.145 (3.68) 0.39 (9.9) 0.65 (16.5) 0.07 (17.7) 9 0.18 (4.57) 0.10 (2.54) 0.15 (3.81) 0.07 DIA. (1.77) 0.125 (3.17) MagnecraftTM Time Delay and Sensor Relays Wiring Diagrams TDR782 Series Accessories Socket 70-782EL8, 70-782-EL14-1, 70-782E14-1, 70-782D14-1 Spring Clip 16-TDR782SC Wiring Diagrams 70-782EL8-1 70-782EL14-1 70-782E14-1 41 12 11 9 41 12 31 21 11 11 10 9 44 8 14 5 44 8 42 4 12 1 42 4 34 7 32 3 4 1 8 5 12 9 14 13 INPUT 14 5 22 12 1 2 4 3 2 1 8 7 6 5 N.C. N.O. COM 24 6 12 11 10 9 14 13 INPUT 13 A1 NEMA IEC 44 8 34 7 24 6 14 5 42 4 32 22 2 12 4 3 2 1 8 7 6 5 12 11 10 9 14 A2 12 41 1 22 12 2 1 COM 14 MODULE INPUT 2 22 6 24 3 32 7 34 4 42 8 44 N.C. N.O. 9 10 11 12 11 21 31 COM 12 1 22 5 41 A2 COM NEMA IEC 2 11 32 6 24 14 9 A1 9 11 INPUT 13 A1 12 11 10 41 31 21 1 12 5 14 N.O. 10 21 INPUT 9 11 24 6 14 5 22 2 12 1 4 3 2 1 8 7 6 5 12 11 10 9 14 13 N.C. N.O. COM INPUT MODULE INPUT 9 14 13 11 A2 A1 INPUT 12 11 10 41 31 21 NEMA IEC 70-379-1 14 13 A1 COM NEMA IEC 13 INPUT N.C. N.O. 13 14 A2 32 3 42 4 8 7 6 5 12 11 10 9 INPUT 13 A1 N.C. 13 INPUT 11 31 42 32 4 3 34 7 44 8 5 N.C. N.O. 70-378-1 14 14 NEMA IEC 70-461-1 3 24 6 4 3 2 1 MODULE INPUT 14 A2 70-782D14-1 34 7 INPUT MODULE INPUT 14 A2 44 8 GROUND LUG 4 N.C. 8 N.O. 44 11 31 12 A2 A1 NEMA IEC COM 41 14 13 INPUT 42 7 34 10 21 3 INPUT GROUND LUG NEMA IEC 21 MagnecraftTM Time Delay and Sensor Relays Description TDRPRO Series SPDT, 12 A; DPDT, 12 A Description Time delay relays that are programmable, multi-function, multi-voltage, and socketcompatible - offering the user the ultimate in design flexibility. The thumb wheel adjustment dials result in no mechanical deviation for supreme accuracy. TDRPRO Relay Feature Benefit Up to 10 functions 5 Timing functions controlled via supply voltage 4 Timing functions controlled via trigger input 1 function of memory latching Broad timing range 0.1 Seconds to 999 hours Panel mount adapter Panel mountable Dust cover Retains settings / keeps dust out Universal power supply 12 - 240 Vac/Vdc Thumb wheel adjustment for function / timing Helps ensure accuracy and reduces timing deviations 2 LED status inicators Indicate coil power / timing out / output state RoHS compliant Environmentally friendly Input Voltage Functions Available (1) Timing Range Contact Configuration Rated Current (A) Standard Part Number 12 to 240 Vac/Vdc A,B,C,D,E,F,G,H,I,J 100 ms to 9990 hrs DPDT 12 TDRPRO-5100 12 to 240 Vac/Vdc A,B,C,D,E,F,G,H,I,J 100 ms to 9990 hrs SPDT 12 TDRPRO-5101 12 to 240 Vac/Vdc A,B,C 100 ms to 9990 hrs DPDT 12 TDRPRO-5102 (1) For function descriptions, see pages 33 and 34. Part Number Explanation Series: TDRPRO = 48x48 Time Delay Relay 22 &RQWDFW&RQJXUDWLRQRI)XQFWLRQV 5100 = DPDT, 10 Functions 5101 = SPDT, 10 Functions 5102 = DPDT, 3 Functions MagnecraftTM Time Delay and Sensor Relays Specifications TDRPRO Series SPDT, 12 A; DPDT, 12 A Specifications Part Number TDRPRO-5100 TDRPRO-5101 TDRPRO-5102 Input Voltage Range 12 to 240 Vac/Vdc 12 to 240 Vac/Vdc 12 to 240 Vac/Vdc Operating Voltage 85% to 115% of Nominal 85% to 115% of Nominal 85% to 115% of Nominal Maximum Power Consumption (AC) 2.5 VA 2.5 VA 2.5 VA Maximum Power Consumption (DC) 2W 2W 2W Contact Configuration DPDT SPDT DPDT Output Current Rating 12 A 12 A 12 A Contact Material Silver Alloy Silver Alloy Silver Alloy Switching Capabilties 240 Vac, 50/60 Hz, 30 Vdc 1/3 HP @ 120 Vac 1/2 HP @ 240 Vac Pilot Duty B300 240 Vac, 50/60 Hz, 30 Vdc 1/3 HP @ 120 Vac 1/2 HP @ 240 Vac Pilot Duty B300 240 Vac, 50/60 Hz, 30 Vdc 1/3 HP @ 120 Vac 1/2 HP @ 240 Vac Pilot Duty B300 Minimum Switching Requirement 100 mA 100 mA 100 mA Functions Available (1) A,B,C,D,E,F,G,H,I,J A,B,C,D,E,F,G,H,I,J A,B,C Time Scales 7 7 7 Time Ranges 0 0 0 0 0 0 0 Repeatability of the time delay @ constant voltage and temperature 0.1% 0.1% 0.1% Reset Time 150 ms 150 ms 150 ms Operate Time 25 ms maximum 25 ms maximum 25 ms maximum Release Time 25 ms maximum 25 ms maximum 25 ms maximum Electrical Life (operations at rated current) (2) 100,000 operations 100,000 operations 100,000 operations Mechanical Life (Unpowered) (2) 10,000,000 operations 10,000,000 operations 10,000,000 operations Dielectric Strength (Input to Contacts) 2500 Vrms 2500 Vrms 2500 Vrms Storage Temperature Range -30C (-22F) to +70C (+158F) -30C (-22F) to +70C (+158F) -30C (-22F) to +70C (+158F) Operating Temperature Range -20C (-4F) to +60C (+140F) -20C (-4F) to +60C (+140F) -20C (-4F) to +60C (+140F) Weight 133 g (4.69 oz) 133 g (4.69 oz) 133 g (4.69 oz) Input Indication Green LED Green LED Green LED Output Indication (Blinks = Timing or On = Energized) RED LED RED LED RED LED Enclosure Rating (according to IEC 60529 IP rating) IP40 IP40 IP40 Approvals cURus (File No. E43641), CE 61810-1, RoHS, cULus (UL Listed [File No. E43641] when used with Magnecraft socket 70-465) cURus (File No. E43641), CE 61810-1, RoHS, cULus (UL Listed [File No. E43641] when used with Magnecraft socket 70-464) cURus (File No. E43641), CE 61810-1, RoHS, cULus (UL Listed [File No. E43641] when used with Magnecraft socket 70-464) Input Characteristics Output Characteristics Timing Characteristics to to to to to to to 999 999 999 999 999 999 999 by by by by by by by 0.1 sec sec 0.1 min min 0.1 hr hr 10 hr 0 0 0 0 0 0 0 to to to to to to to 999 999 999 999 999 999 999 by by by by by by by 0.1 sec sec 0.1 min min 0.1 hr hr 10 hr 0 0 0 0 0 0 0 to to to to to to to 999 999 999 999 999 999 999 by by by by by by by 0.1 sec sec 0.1 min min 0.1 hr hr 10 hr General Characteristics (1) For function descriptions, see pages 33 and 34. (2) Actual product life will vary based on electrical load, duty cycle, application, and environmental conditions. 23 MagnecraftTM Time Delay and Sensor Relays Dimensions, Wiring Diagrams TDRPRO Series SPDT, 12 A; DPDT, 12 A Dimensions -- inches (millimeters) 1.9 (48) 0.23 (6) 2.8 (72) 1.9 (48) 0.25 (6.35) 0.06 (1.52) 3.15 (80.0) Wiring Diagrams EXTERNAL CONTROL SWITCH 4 6 5 7 3 2 24 1 11 8 9 10 DRY SWITCH ONLY 4 5 6 3 7 2 1 8 INPUT INPUT TDRPRO-5100 TDRPRO-5101 EXTERNAL CONTROL SWITCH DRY SWITCH ONLY 4 5 6 3 2 7 1 8 INPUT TDRPRO-5102 MagnecraftTM Time Delay and Sensor Relays Description TDRSOX/SRX Series DPDT, 12 A Description Time delay relays that are dual-function, dual-voltage and socket-compatible. The integrated DIP switching allows the user to easily adjust a wide timing range. Octal and square base available. Feature Benefit Integrated DIP switch Simplifies the programming of the functions and timing Output and input indication Red and green LED for status check Removable knob Tamper resistance Optional side and top flange mounting Flexibility in mounting techniques Socket compatible Makes for easy installation and replacement TDRSOXB Relay TDRSRXP Relay Input Voltage Functions Available (1) Timing Range Contact Configuration Rated Current (A) Base Type Standard Part Number 120 Vac/Vdc A, C 100 ms to 10 hrs DPDT 12 8 Blade Square Base TDRSOXB-120V 12 Vac/Vdc A, C 100 ms to 10 hrs DPDT 12 8 Blade Square Base TDRSOXB-12V 24 Vac/Vdc A, C 100 ms to 10 hrs DPDT 12 8 Blade Square Base TDRSOXB-24V 120 Vac/Vdc A, C 100 ms to 10 hrs DPDT 12 8 Pin Octal Base TDRSOXP-120V 12 Vac/Vdc A, C 100 ms to 10 hrs DPDT 12 8 Pin Octal Base TDRSOXP-12V 24 Vac/Vdc A, C 100 ms to 10 hrs DPDT 12 8 Pin Octal Base TDRSOXP-24V 120 Vac/Vdc D, E 100 ms to 10 hrs DPDT 12 11 Blade Square Base TDRSRXB-120V 12 Vac/Vdc D, E 100 ms to 10 hrs DPDT 12 11 Blade Square Base TDRSRXB-12V 24 Vac/Vdc D, E 100 ms to 10 hrs DPDT 12 11 Blade Square Base TDRSRXB-24V 120 Vac/Vdc D, E 100 ms to 10 hrs DPDT 12 11 Pin Octal Base TDRSRXP-120V 12 Vac/Vdc D, E 100 ms to 10 hrs DPDT 12 11 Pin Octal Base TDRSRXP-12V 24 Vac/Vdc D, E 100 ms to 10 hrs DPDT 12 11 Pin Octal Base TDRSRXP-24V (1) For function descriptions, see pages 33 and 34. Part Number Explanation Series: TDR = Time Delay Relay Terminal Style: P = Pins Octal B = Blade Square Functions: SOX = On Delay/Interval SRX = Off Delay/Retriggerable One Shot Input Voltage: 12V = 12 Vac/Vdc 24V = 24 Vac/Vdc 120V = 120 Vac/Vdc 240V = 240 Vac/Vdc 25 MagnecraftTM Time Delay and Sensor Relays Specifications TDRSOX/SRX Series DPDT, 12 A Specifications Part Number TDRSOX TDRSRX Input Voltage Range 12, 24, 120 Vac/Vdc 240 Vac 12, 24, 120 Vac/Vdc 240 Vac Operating Voltage 80% to 110% of Nominal 80% to 110% of Nominal Maximum Power Consumption (AC) 2.5 VA 2.5 VA Maximum Power Consumption (DC) 2.5 W 2.5 W Contact Configuration DPDT DPDT Output Current Rating 12 A 12 A Contact Material Silver Alloy Silver Alloy Switching Capabilties 240 Vac, 50/60 Hz, 30 Vdc 1/3 HP @ 120 Vac 1/2 HP @ 240 Vac Pilot Duty B300 240 Vac, 50/60 Hz, 30 Vdc 1/3 HP @ 120 Vac 1/2 HP @ 240 Vac Pilot Duty B300 Minimum Switching Requirement 100 mA at 5 Vac or Vdc 100 mA at 5 Vac or Vdc Functions Available (1) A,C D,E Time Scales 8 8 Time Ranges 0.1 sec to 1 sec 1 sec to 10 sec 10 sec to 100 sec 0.1 min to 1 min 1 min to 10 min 10 min to 100 min 0.1 hr to 1 hr 1 hr to 10 hr 0.1 sec to 1 sec 1 sec to 10 sec 10 sec to 100 sec 0.1 min to 1 min 1 min to 10 min 10 min to 100 min 0.1 hr to 1 hr 1 hr to 10 hr Tolerance 10% of Mechanical setting 10% of Mechanical setting Repeatability @ constant voltage and temperature 1% 1% Reset Time 150 ms 150 ms Trigger Pulse Length N/A 50 ms minimum Electrical Life (operations at rated current) (2) 100,000 operations 100,000 operations Mechanical Life (Unpowered) (2) 10,000,000 operations 10,000,000 operations Dielectric Strength (Input to Contacts) 2500 Vrms 2500 Vrms Storage Temperature Range -30C (-22F) to +70C (+158F) -30C (-22F) to +70C (+158F) Operating Temperature Range -20C (-4F) to +60C (+140F) -20C (-4F) to +60C (+140F) Weight 133 g (4.69 oz) 133 g (4.69 oz) Input Indication Green LED Green LED Output Indication RED LED RED LED Enclosure Rating (according to IEC 60529 IP rating) IP40 IP40 Approvals cULus (UL Listed [File No. E43641] when used with Magnecraft sockets), cURus (File No. E43641), RoHS cULus (UL Listed [File No. E43641] when used with Magnecraft sockets), cURus (File No. E43641), RoHS Input Characteristics Output Characteristics Timing Characteristics General Characteristics (1) For function descriptions, see pages 33 and 34. (2) Actual product life will vary based on electrical load, duty cycle, application, and environmental conditions. 26 MagnecraftTM Time Delay and Sensor Relays Dimensions, Wiring Diagrams, Selecting Time Range and Function TDRSOX/SRX Series DPDT, 12 A Dimensions -- inches (millimeters) TDR(SOX/SRX)P TDR(SOX/SRX)B 1.42 (36) 2.6 (65) 0.8 (2) 3.0 (77) 1.4 (36) 0.7 (17) 1.73 (44) 3.4 (86) 2.6 (65) 0.8 (2.0) 0.7 (17) 1.73 (44) 0.13 (3.3) 0.13 (3.3) Wiring Diagrams EXTERNAL CONTROL SWITCH EXTERNAL CONTROL SWITCH 1 2 3 12 4 14 32 5 34 22 6 1 12 4 14 24 7 9 11 A A1 21 B A2 3 22 6 24 7 11 A A1 OFF DELAY 6 5 4 7 8 9 3 9 21 B A2 2 1 11 DRY SWITCH ONLY 4 5 6 3 2 10 7 1 8 INPUT INPUT ON DELAY NEMA IEC NEMA IEC OFF DELAY ON DELAY SRXB SOXB SRXP SOXP cULus Listed with 70-750DL11-1 or 70-750E11-1 or 70-465-1 cULus Listed with 70-750DL8-1 or 70-750E8-1 or 70-464-1 cULus Listed with 70-788EL11-1 or 70-463-1 sockets Selecting Function Selecting Time Range Time Range Digital Switch Position Function SOX (1) Digital Switch Position II III IV On Delay OFF 0.1 sec - 1 sec OFF OFF OFF Interval ON 1 sec - 10 sec OFF OFF ON Function SRX 10 sec - 100 sec OFF ON OFF On Delay OFF 0.1 min - 1 min OFF ON ON Interval ON 1 min - 10 min ON OFF OFF 10 min - 100 min ON OFF ON 0.1 hr - 1 hr ON ON OFF 1hr - 10 hr ON ON ON Digital Switch Position (1) For function descriptions, see pages 33 and 34. 27 MagnecraftTM Time Delay and Sensor Relays Description TDRPRO/SOX/SRX Series Accessories DIN Rail 16-700DIN, Socket 70-750 Series, Spring Clip 16-TDRPROSC Description The TDRPRO accessories create a complete system solution for all your application needs. The 70-750DL socket offers an alternate installation option for plug-in models. The 16-TDRPROSC retention clip holds the relay securely in place while allowing quick and efficient installation and maintenance. 70-750DL8-1 Socket 70-750E8-1 Socket 16-TDRPROSC Spring Clip 16-700DIN DIN Rail Relay Accessories Description Function For Use With Relays Packaging Minimum Standard Part Number Socket Mounts directly to DIN Rail or Panel TDRPRO-5101, TDRPRO-5102, TDRSOX 10 70-750DL8-1 Socket Mounts directly to DIN Rail or Panel TDRPRO-5100, TDRSRX 10 70-750DL11-1 Socket DIN/Panel Mount with Elevator Terminals TDRPRO-5101, TDRPRO-5102, TDRSOX 10 70-750E8-1 Socket DIN/Panel Mount with Elevator Terminals TDRPRO-5100, TDRSRX 10 70-750E11-1 Socket DIN/Panel Mount with Screw Terminals & Clamping Plates TDRPRO-5100, TDRSRX 10 70-465-1 Socket DIN/Panel Mount with Screw Terminals & Clamping Plates TDRPRO-5101, TDRPRO-5102, TDRSOX 10 70-464-1 Socket Panel Mount with Screw Terminals & Clamping Plates TDRPRO-5100, TDRSRX 10 70-170-1 Socket Panel Mount with Screw Terminals & Clamping Plates TDRPRO-5101, TDRPRO-5102, TDRSOX 10 70-169-1 Socket Accessories Description Function Coil Voltage For Use With Relays Packaging Minimum Standard Part Number Metal Holding Clip Helps secure relay in socket - TDRPRO 10 16-TDRPROSC Metal DIN Rail Quick installation and removable of sockets - TDRSOX/SRX 10 16-700DIN Write-On Plastic Labels Allows for identification of circuits in mult-relay applications - TDRSOX/SRX 10 16-782FT-1 28 MagnecraftTM Time Delay and Sensor Relays Specifications TDRPRO/SOX/SRX Series Accessories DIN Rail 16-700DIN, Socket 70-750 Series, Spring Clip 16-TDRPROSC Specifications Part Number 70-750DL8-1 70-750DL11-1 70-750E8-1 70-750E11-1 Contact Configuration DPDT 3PDT DPDT 3PDT Number of Terminals 8 11 8 11 Mounting Style Panel / DIN rail Panel / DIN rail Panel / DIN rail Panel / DIN rail Current Rating 16 A 5A 12 A 12 A Nominal Voltage Rating 300 V 600 V 600 V 300 V Temperature Storage Range -40C (-40F) to +105C (+221F) -40C (-40F) to +105C (+221F) -40C (-40F) to +105C (+221F) -40C (-40F) to +105C (+221F) IP 20 IP 20 IP 20 Protection Category according to IP 20 IEC 60529 IP rating (FingersafeTM) Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Steel, Zinc Plated Steel, Zinc Plated Steel, Zinc Plated Screw Style Combination Head Combination Head Combination Head Combination Head Screw Size M3.5 mm M3.5 mm M3.5 mm M3.5 mm Maximum Screw Torque 9 lb-in (1.0 N*m) 9 lb-in (1.0 N*m) 9 lb-in (1.0 N*m) 9 lb-in (1.0 N*m) Terminal Connection Screw Clamping Screw Clamping Elevator Elevator Terminal Layout Non-Logic Non-Logic Logic Logic Maximum Wire Size Solid Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Stranded Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Solid Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Stranded Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Solid Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Stranded Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Solid Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Stranded Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm DIN Rail Mounting, EN 60715 35 mm (1.38 in) 35 mm (1.38 in) 35 mm (1.38 in) 35 mm (1.38 in) Chassis Mount Screw Torque 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) Flammability Rating 94V-0 Class 94V-0 Class 94V-0 Class 94V-0 Class Body Color Light Gray Light Gray Light Gray Light Gray DIN Locking Method Red Plastic Locking Clip Red Plastic Locking Clip Red Plastic Locking Clip Red Plastic Locking Clip Agency Approvals cURus (File No. E70550), CSA (File No. 40787), CE 60947-1, RoHS cURus (File No. E70550), CSA (File No. 40787), CE 60947-1, RoHS cURus (File No. E70550), CSA (File No. 40787), CE 60947-1, RoHS cURus (File No. E70550), CSA (File No. 40787), CE 60947-1, RoHS Part Number 70-169-1 70-170-1 70-464-1 70-465-1 Contact Configuration DPDT 3PDT DPDT 3PDT Number of Terminals 8 11 8 11 Mounting Style Panel Panel Panel / DIN rail Panel / DIN rail Current Rating 15 A 15 A 15/10 A 15/5 A 300/600 V Nominal Voltage Rating 300 V 600 V 300/600 V Temperature Storage Range -40C (-40F) to +105C (+221F) -40C (-40F) to +105C (+221F) -40C (-40F) to +105C (+221F) -40C (-40F) to +105C (+221F) Internal Metal Tracks Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Copper Alloy, Zinc Plated Screw Terminals Steel, Zinc Plated Steel, Zinc Plated Steel, Zinc Plated Steel, Zinc Plated Screw Style Combination Head Combination Head Combination Head Combination Head Screw Size M3.5 mm M3.5 mm M3.5 mm M3.5 mm Maximum Screw Torque 9 lb-in (1.0 N*m) 9 lb-in (1.0 N*m) 9 lb-in (1.0 N*m) 9 lb-in (1.0 N*m) Terminal Connection Screw Clamping Screw Clamping Screw Clamping Screw Clamping Terminal Layout Non-Logic Non-Logic Non-Logic Non-Logic Maximum Wire Size Solid Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Stranded Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Solid Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Stranded Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Solid Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Stranded Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Solid Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm Stranded Cu 12 / 14 (2) AWG, 4 / 2.5 (2) mm DIN Rail Mounting, EN 60715 35 mm (1.38 in) 35 mm (1.38 in) 35 mm (1.38 in) 35 mm (1.38 in) Chassis Mount Screw Torque 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) 7 lb-in (0.8 N*m) Flammability Rating 94V-0 Class 94V-0 Class 94V-0 Class 94V-0 Class Body Color Light Gray Light Gray Light Gray Light Gray DIN Locking Method - - Red Plastic Locking Clip Red Plastic Locking Clip Product Certifications cURus (File No. E70550), CSA (File No. 97877), CE 60947-1, RoHS cURus (File No. E70550), CSA (File No. 97877), CE 60947-1, RoHS cURus (File No. E70550), CSA (File No. 97877), CE 60947-1, RoHS cURus (File No. E70550), CSA (File No. 97877), CE 60947-1, RoHS 29 MagnecraftTM Time Delay and Sensor Relays Dimensions TDRPRO/SOX/SRX Series Accessories DIN Rail 16-700DIN, Socket 70-750 Series, Spring Clip 16-TDRPROSC Dimensions -- inches (millimeters) 70-750DL8-1 Mounts directly to DIN Rail or Panel 1.42 (36) 70-750DL11-1 Mounts directly to DIN Rail or Panel 1.45 (37) 1.42 (36) 1.1 (27.9) 22 11 12 5 1 4 24 21 14 6 8 3 3.0 (77.5) 1.5 (38) 1.1 (27.9) 3.02 (76.8) 2.86 (72.7) 1.58 (40) 24 22 8 7 5 14 9 3 A2 INPUT 10 A1 INPUT 7 2 70-750E8-1 DIN/Panel Mount with Elevator Terminals 70-750E11-1 DIN/Panel Mount with Elevator Terminals 0.86 (22) 0.86 (22) 22 6 2.95 (75) 30 4 5 9 3 INPUT A2 7 2 IEC: NEMA: A2 21 7 7 1.49 (38) 11 8 0.12 (30) 1 2 INPUT A2 3 4 INPUT A1 10 10 1.06 (27) 14 12 5 7 8 A2 A2 A1 22 0.12 (3.1) 1.45 (37) INPUT A1 24 32 34 14 2.95 (75) A2 1.06 (27) 12 0.12 (3.1) 1.45 (37) A1 INPUT 2 1.35 (34.2) 1.2 (30) 24 1 6 IEC: NEMA: A2 INPUT 31 10 1.49 (38) 4 34 1.58 (40) IEC: NEMA: 12 11 21 31 11 3.19 (81) 0.15 (3.8) 32 2 IEC: NEMA: 11 A1 21 11 6 0.12 (30) 1 2 0.15 (3.8) MagnecraftTM Time Delay and Sensor Relays Dimensions (continued) TDRPRO/SOX/SRX Series Accessories DIN Rail 16-700DIN, Socket 70-750 Series, Spring Clip 16-TDRPROSC Dimensions -- inches (millimeters) 9 8 7 6 1.29 (33) 8 1 2 0.16 (4.2) 4 3 2 2.12 (54) 1.68 (42.8) 6 2.02 (51) 2.0 (50) 0.625 (16) 0.25 (6.3) 7 0.59 (15) 1 70-169-1 Panel Mount with Screw Terminals & Clamping Plates 5 1.6 (40) 11 0.17 DIA. (4.3) 70-464-1 DIN/Mount with Screw Terminals & Clamping Plates 0.97 (24.6) 1.29 (32) 3 5 2.16 (54.8) 3 4 5 6 2.25 (57) 7 1.12 (28) 1.01 (25.6) 2.59 (65) 2 10 10 1.02 (25) 2 9 3 4 2.05 (52) 11 4 1 0.25 (6.3) 8 1.6 DIA. (40) 2.06 (52) 7 0.97 (24.6) 2.5 (64) 2.2 (56) 0.629 (16) 6 2.32 (59) 70-170-1 Panel Mount with Screw Terminals & Clamping Plates 5 70-465-1 DIN/Mount with Screw Terminals & Clamping Plates 8 1 0.17 DIA. (4.3) 31 MagnecraftTM Time Delay and Sensor Relays Wiring Diagrams (continued) TDRPRO/SOX/SRX Series Accessories DIN Rail 16-700DIN, Socket 70-750 Series, Spring Clip 16-TDRPROSC Wiring Diagrams 70-750E8-1 32 8 34 9 70-750E11-1 22 5 24 7 6 7 12 4 14 3 32 8 34 9 8 10 5 11 1 11 6 21 31 1 MODULE INPUT 1 2 11 A1 INPUT 10 10 A2 A2 INPUT NEMA IEC 12 32 8 5 1 4 24 21 14 6 8 3 11 6 21 31 1 2 11 A1 INPUT 7 2 7 14 3 70-464-1 11 31 21 6 1 11 A1 10 2 INPUT 1 INPUT 11 2 5 6 6 21 NEMA IEC 32 2 1 8 7 INPUT 1 2 7 3 6 4 7 INPUT 8 8 7 24 32 3 4 5 6 14 12 22 24 NEMA IEC 1 Coil Bus Jumper 10 2 INPUT A2 2 A1 NEMA IEC A1 70-169-1 21 6 24 7 32 8 10 A2 INPUT 2 MODULE INPUT 6 7 22 5 22 5 12 4 5 8 5 4 11 INPUT 9 34 3 5 3 1 24 6 3 10 2 11 11 31 1 1 11 NEMA IEC 12 4 5 3 2 7 3 14 2 A1 INPUT 7 A2 INPUT 14 3 4 6 4 9 8 5 22 9 A2 9 4 4 34 21 10 3 12 A2 11 1 14 6 7 11 10 70-170-1 A1 4 31 NEMA IEC 70-465-1 7 9 Coil Bus Jumper A2 12 5 8 3 MODULE INPUT NEMA IEC 22 11 9 6 8 24 34 4 5 2 MODULE INPUT 10 10 A2 A2 INPUT 11 3 10 2 70-750DL11-1 4 9 3 11 6 22 12 4 14 3 8 4 9 22 5 24 7 7 5 70-750DL8-1 8 2 1 8 21 1 11 NEMA IEC A1 INPUT Application Data MagnecraftTM Time Delay and Sensor Relays Time Delay Relay Functions: Power Trigger Function Description On Delay (A) When the input voltage U is applied, timing delay T begins. Relay contacts R change state after time delay is complete. Contacts R return to their shelf state when input voltage U is removed. Trigger switch is not used in this function. U Repeat Cycle: Starting Open (B) When input voltage U is applied, time delay T begins. When time delay T is complete, relay contacts R change state for time delay T. This cycle will repeat until input voltage U is removed. Trigger switch is not used in this function. U Interval (C) When input voltage U is applied, relay contacts R change state immediately and timing cycle begins. When time delay T is complete, contacts return to shelf state. When input voltage U is removed, contacts will also return to their shelf state. Trigger switch is not used in this function. Repeat Cycle: Starting Closed (F) When input voltage U is applied, relay contacts R change state immediately and time delay T begins. When time delay T is complete, contacts return to their shelf state for time delay T. This cycle will repeat until input voltage U is removed. Trigger switch is not used in this function. Pulse Generator (G) Upon application of input voltage U, a single output pulse of 0.5 seconds is delivered to relay after time delay T. Power must be removed and reapplied to repeat pulse. Trigger switch is not used in this function. Timing Chart Relays T R R time T T T T OFF ON OFF ON time U T R U R U R time T T T T ON OFF ON OFF 821, 822, TDR782, TDRPRO-5100, TDRPRO-5101, TDRPRO-5102, TDRSOX 821, 822, TDRPRO-5100, TDRPRO-5101, TDRPRO-5102, TDRSOX 821, 822, TDRPRO-5100, TDRPRO-5101, TDRPRO-5102 821, 822, TDRPRO-5100, TDRPRO-5101 time T 821, 822, TDRPRO-5100, TDRPRO-5101 Pulse time Timing Chart Key U = Input voltage (Power supply) R = Relay contacts T = Setting time 33 Application Data (continued) MagnecraftTM Time Delay and Sensor Relays Time Delay Relay Functions: SwitchTrigger Function Description Off Delay (D) Input voltage U must be applied continuously. When trigger switch S is closed, relay contacts R change state. When trigger switch S is opened, delay T begins. When delay T is complete, contacts R return to their shelf state. If trigger switch S is closed before time delay T is complete, then time is reset. When trigger switch S is opened, the delay begins again, and relay contacts R remain in their energized state. If input voltage U is removed, relay contacts R return to their shelf state. Retriggerable One Shot (E) One Shot (H) On and Off Delay (I) Upon application of input voltage U, the relay is ready to accept trigger signal S. Upon application of the trigger signal S, the relay contacts R transfer and the preset time T begins. At the end of the preset time T, the relay contacts R return to their normal condition unless the trigger switch S is opened and closed prior to time out T (before preset time elapses). ontinuous cycling of the trigger switch S at a rate faster than the preset time will cause the relay contacts R to remain closed. If input voltage U is removed, relay contacts R return to their shelf state. Upon application of input voltage U, the relay is ready to accept trigger signal S. Upon application of the trigger signal S, the relay contacts R transfer and the preset time T begins. uring time-out the trigger signal S is ignored. The relay resets by applying the trigger switch S when the relay is not energized. Input voltage U must be applied continuously. When trigger switch S is closed, time delay T begins. When time delay T is complete, relay contacts R change state and remain transferred until trigger switch S is opened. If input voltage U is removed, relay contacts R return to their shelf state. Timing Chart Relays U 821, 822, S T TDRSRX R U - 100 - 101 - 10 time T T 821, 822, S TDRSRX R - 100 - 101 - 10 time U T T 821, 822, S R U time T T 821, 822, S R - 100 - 101 - 100 - 101 time U Memory Latch (J) Input voltage U must be applied continuously. Output changes state with every trigger switch S closure. If input voltage U is removed, relay contacts R return to their shelf state. R Timing Chart Key U = nput oltage ( ower supply) S = Switch trigger (Control switch) R = Relay contacts T = Setting time 34 821, 822, S time - 100 - 101 Application Data (continued) MagnecraftTM Time Delay and Sensor Relays Definition A time delay is defined as the controlled period between the functioning of two events. A time delay relay is a combination of an electromechanical output relay and a control circuit. The control circuit is comprised of solid state components that control operation of the relay and timing range. Typical time delay functions include On-Delay, Repeat cycle (starting off), Interval, Off-Delay, Retriggerable One Shot, Repeat cycle (starting on), Pulse Generator, One Shot, On/Off Delay, and Memory Latch. Each function is explained in the table below. Time delay relays have a broad choice of timing ranges from less than one second to many days. There are many choices of timing adjustments from calibrated external knobs, DIP switches, thumbwheel switches, or recessed potentiometer. Principle of Operation Time delay relays are simply control relays with a time delay built in. Their purpose is to control an event based on time. The difference between relays and time delay relays is when the output contacts open & close: on a control relay, it happens when voltage is applied and removed from the coil; on time delay relays, the contacts will open or close before or after a pre-selected, timed interval. Typically, time delay relays are initiated or triggered by one of two methods: application of input voltage (On Delay, Interval On, Flasher, Repeat Cycle, Delayed Interval & Interval/Flasher). opening or closing of a trigger signal (Off Delay, Single Shot & Watchdog). These trigger signals can be one of two designs: a control switch (dry contact), i.e., limit switch, push button, float switch, etc. voltage (commonly known as a power trigger). Definitions: Input Voltage: Control voltage applied to the input terminals (see wiring diagrams below). Depending on the function, input voltage will either initiate the unit or make it ready to initiate when a trigger signal is applied. Trigger Signal: On certain timing functions, a trigger signal is used to initiate the unit after input voltage has been applied. As noted above, this trigger signal can either be a control switch (dry contact switch) or a power trigger (voltage). Output (Load): Every time delay relay has an internal relay (usually mechanical) with contacts that open & close to control the load. They are represented by the dotted lines in the wiring diagrams. Note that the user must provide the voltage to power the load being switched by the output contacts of the time delay relay. 35 Application Data (continued) MagnecraftTM Time Delay and Sensor Relays Applications Magnecraft time delay and sensor relays are designed to provide cost effective solutions for your industrial timing and sensing needs. Available in a wide array of forms, fits and functions; Magnecraft timers offer flexibility and performance for process control and industrial building applications. Typical Examples of Timer Applications 36 Automation Panels Food & Beverage Process controls, motor controls, emergency lighting Commercial/industrial cooking equipment, filtration systems, bottling, chillers, convection ovens Packaging Machinery Lighting Control Conveyor motors, food processors, product/shrink wrap, solenoid controls Traffic signal systems, motorway information systems, theatrical lighting, ballast lighting Power Supplies Material Handling Universal power supplies, battery backup systems Motor control, conveyor controls HVAC & Refrigeration Appliances Anti-condensation equipment, compressor controls, blower controls, motorized duct/vent controls Air conditioners, water heaters, portable heaters, spa controls, water pumps Website Guide MagnecraftTM Time Delay and Sensor Relays The Magnecraft website (www.serelays.com) is designed to enable users to easily find the proper relay to fit design requirements and to help simplify and shorten workflow. Easily find the proper relay to fit design requirements n Online Catalog Find the right product by choosing specifications, compare products side-byside, and view technical specifications, 2D and 3D drawings, and associated accessories. n Cross Reference Search Search our comprehensive database to identify products by manufacturer and part number, and link directly to part specifications. n 3D CAD Library View, email, download, or insert a file directly into your open CAD software. There are 18 different file formats to choose from. 3D Models n Order Free Samples Magnecraft offers free samples as a courtesy to individuals and companies evaluating our products for their designs and applications. Sample orders are subject to approval. Simplify and shorten workflow n Interactive Tools View interactive demonstrations; such as our Time Delay Relay Interactive Demo (left) which visually demonstrates the ten different timing functions offered on Magnecraft time delay relays. n Distributor Inventory Search Search authorized distributors' current Magnecraft inventory and buy online. (Buy online not available for all distributors). Time Delay Relay Demo 37 MagnecraftTM Time Delay and Sensor Relays Index 16-700DIN 16-788C1 13 17 28 17 28 13 16-TDR782SC 17 16-TDRPROSC 28 70-169-1 28 70-170-1 28 70-378-1 17 70-379-1 17 70-461-1 70-465-1 17 28 28 70-750DL11-1 28 70-750DL8-1 28 70-750E11-1 28 70-750E8-1 28 70-782D14-1 17 70-782E14-1 17 70-782EL14-1 17 70-782EL8-1 17 16-782FT-1 821TD10H-UNI 4 822TD10H-UNI 4 831VS-120A 7 831VS-240A 7 841CS1-UNI 10 841CS2-UNI 10 841CS5-UNI 10 841CS8-UNI 10 TDR782XBXA-110A 14 TDR782XBXA-24A 14 TDR782XBXA-24D 14 TDR782XDXA-110A 14 TDR782XDXA-12D 14 TDR782XDXA-230A 14 TDR782XDXA-24A 14 TDR782XDXA-24D 14 TDRPRO-5100 22 TDRPRO-5101 22 TDRPRO-5102 22 TDRSOXB-120V 25 TDRSOXB-12V 25 TDRSOXB-24V 25 TDRSOXP-120V 25 TDRSOXP-12V 25 TDRSOXP-24V 25 TDRSRXB-120V 25 TDRSRXB-12V 25 TDRSRXB-24V 25 TDRSRXP-120V 25 TDRSRXP-12V 25 TDRSRXP-24V 25 38 www.serelays.com Schneider Electric USA, Inc. 1300 S. Wolf Rd. Des Plaines, IL 60018 Tel: 847-441-2540 The information and dimensions in this catalog are provided for the convenience of our customers. While this information is believed to be accurate, Schneider Electric reserves the right to make updates and changes without prior notification and assumes no liability for any errors or omissions. Design: Schneider Electric Photos: Schneider Electric (c) 2011 Schneider Electric. All Rights Reserved 8501CT1104 November 2011