Table 1. Specifications
Characteristic North America EMEA (Europe)
Product type Honeywell general purpose LS limit switch,
compact and plug-in
Honeywell general purpose LS-4 limit switch,
compact and plug-in
Acutators side rotary, side rotary (maintained) top pin plunger, top roller plunger, wobble coil spring,
wobble aluminum rod, wobble cat whisker, wobble sst coil spring
Circuitry single pole double throw (SPDT) double break, single pole double throw (SPDT) double break
Electrical 10 A (see Table 2) AC 15, A300; DC 13, P300
Housing material compact: epoxy coated zinc die cast
plug-in: epoxy coated aluminum die cast epoxy coated aluminum die cast
Conduit 0.5 – 14 NPT 20 mm or PG13,5
Housing seal rating NEMA 1,3,4, 6 and 13 IP67, NEMA 1,4 and 13
Operating temperature standard: -29 °C to 71 °C [-20 °F to 160 °F]
high temp.: -29 °C to 120 °C [-20 °F to 248 °F]
standard: -30 °C to 70 °C [-22 °F to 158 °F]
high temp.: -30 °C to 120 °C [-22 °F to 248 °F]
Agency certifications Compact with –L sufx UL le 12252, CSA le 57325 CE, EN60947-5-41, IEC60947-5-4
Table 2. Electrical Ratings
Electrical
Code
Electrical Ratings
A 10 A, 120, 240 or 480 Vac; 1/3 hp 120 Vac; 3/4 hp 240 Vac; 0.8 amp, 115 Vdc;
0.4 amp, 230 Vdc; 0.1 amp, 550 Vdc, Pilot Duty, 600 Vac max.
B10 A, 120, 240 or 480 Vac; 1/4 hp 120 Vac; 1/2 hp 240 Vac; Pilot Duty, 600 Vac max.
C10 A, 1/3 hp 120 Vac
D10 A, 120, 240 or 480 Vac; 1/4 hp 120 Vac; 1/2 hp 240 Vac; 0.8 amp, 115 Vdc; 0.4 amp, 230 Vdc;
0.1 amp, 550 Vdc, Pilot Duty, 600 Vac max.
E10 A, 120, 240 or 480 Vac; 1/3 hp 120 Vac; 3/4 hp 240 Vac; Pilot Duty, 600 Vac max.
F5 A, 6 V; 1 A, 24 V; 0.4 A, 220 V
GUL & CSA; 10 A, 125, 250 or 480 Vac; 1/3 hp 125 Vac; 3/4 hp 250 Vac; 0.8 amp, 115 Vdc; 0.4 amp, 230 Vdc
HUL & CSA; 10 A, 125, 250 or 480 Vac; 1/4 hp 125 Vac; 1/2 hp 250 Vac; 0.8 amp, 115 Vdc; 0.4 amp, 230 Vdc
J
EN60947-5-1, IEC 60947-5-1
Designation &
Category
Thermal Current,
It(Amps)
Rated Operational
Voltage, Ue
Rated Operational
Amps, Ie VA rating Make VA rating Break
ac
AC15, A300 10 120 6 7200 720
AC15, A300 10 240 3 7200 720
dc
DC13, P300 5 125 1.1 138 138
DC13, P300 5 250 0.55 138 138