All specifications are subject to change without notice.
(1/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
This is an ultra-thin, high-performance standard power supply that
is both energy efficient and environmentally friendly. Utilizing
TDK’s unique material, mounting, noise reduction and thermal
analysis simulation technologies, these products have been
reduced by 50% and 60% in volume and weight respectively com-
pared to existing TDK products. All components are lead-free and
compatible with the environmental assessment program.
Highly efficient 5V, 100W type products deliver 83% efficiency
(with 100V input)
FEATURES
Conforms to EN61000E-3-2 regulations for high harmonic cur-
rents.
Wide input (AC.100-200) No toggling required.
Conforms to EMS standards EN61000-4-2, 3, 4, 5, 6, 8 and 11.
Conforms to FCC-B and VCCI-B regulations for radiating and
transmission noise.
•CE certified.
Approved by safety standards (UL, CSA and TÜV). Conforms to
the Electrical Appliance and Material Safety Law.
5-year limited warrantee.
Life span of electrolytic capacitor: 60,000hrs. or more.
Lead-free.
Does not use designated bromine flameproof material (PBPEs
and PBBs).
Available in 1U and 2U rack sizes.
These are particularly suited for situations that call for thin prod-
ucts. They are designed so that they can be attached on both
sides.
The remote control feature (which was optional in previous prod-
ucts) is now standard and can be used by toggling an internal
switch.
APPLICATIONS
Semiconductor fabrication equipment
LED displays
Wire and wireless communication equipment
Other industrial equipment
PART NUMBERS AND RATINGS
50W TYPE
100W TYPE
1 L-type product without top-facing terminal block cover.
2 3.3V, 15V and 28V products are scheduled for December 2003.
3 Without cover and L type products are scheduled for January 2004.
Output voltage
(V)
Current
(A)
Part No.
Without cover3With cover L type1, 3
3.3212.5 RTW03-12R RTW03-12RC RTW03-12RL
5 10 RTW05-10R RTW05-10RC RTW05-10RL
12 4.3 RTW12-4R3 RTW12-4R3C RTW12-4R3L
1523.5 RTW15-3R5 RTW15-3R5C RTW15-3R5L
24 2.2 RTW24-2R2 RTW24-2R2C RTW24-2R2L
2821.8 RTW28-1R8 RTW28-1R8C RTW28-1R8L
48 1.1 RTW48-1R1 RTW48-1R1C RTW48-1R1L
Output voltage
(V)
Current
(A)
Part No.
Without cover3With cover L type1, 3
3.3225 RTW03-25R RTW03-25RC RTW03-25RL
5 20 RTW05-20R RTW05-20RC RTW05-20RL
12 8.4 RTW12-8R4 RTW12-8R4C RTW12-8R4L
1526.7 RTW15-6R7 RTW15-6R7C RTW15-6R7L
24 4.2 RTW24-4R2 RTW24-4R2C RTW24-4R2L
2823.6 RTW28-3R6 RTW28-3R6C RTW28-3R6L
48 2.1 RTW48-2R1 RTW48-2R1C RTW48-2R1L
All specifications are subject to change without notice.
(2/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
RTW50W TYPE
SPECIFICATIONS AND STANDARDS
1Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
2Multiply by 1.5 for use at 100 MHz in a temperature range of –10 to 0°C.
3There will be a decrease in output voltage during cold starts in a temperature range of –20 to 0°C. It may take up to three seconds for the voltage to
stabilize.
Part No.
Without cover RTW03-12R RTW05-10R RTW12-4R3 RTW15-3R5 RTW24-2R2 RTW28-1R8 RTW48-1R1
With cover RTW03-12RC RTW05-10RC RTW12-4R3C RTW15-3R5C RTW24-2R2C RTW28-1R8C RTW48-1R1C
L type RTW03-12RL RTW05-10RL RTW12-4R3L RTW15-3R5L RTW24-2R2L RTW28-1R8L RTW48-1R1L
Rated output voltage and current13.3V • 12A 5V • 10A 12V4.3A 15V • 3.5A 24V • 2.2A 28V • 1.8A 48V • 1.1A
Maximum output power W 41.2 50 51.6 52.5 52.8 50.4 52.8
Input conditions
Input voltage Eac V 85 to 265[Rated: 100-240]
Input frequency Hz 47 to 66[Rated: 50-60](Single phase)
Input current A 0.7max./0.4max.[AC.100-120/200-240V](3.3V: 0.6max./0.3max.)
Fuse rating A 2[Built-in]
Surge current A 14typ./28typ.[AC.100/200V, 1st surge current, 25°C, cold start]
Leakage current mA 0.45max./0.6max.[AC.100(Electrical Appliance and Material Safety Law)/240V(UL, IEC)]
Power factor 0.99/0.94typ.[AC.100/240V]
Efficiency % 100V 75typ. 80typ. 81typ. 82typ. 82typ. 82typ. 82typ.
% 200V 77typ. 82typ. 83typ. 85typ. 85typ. 85typ. 85typ.
Output characteristics
Output voltage Edc V 3.3 5 12 15 24 28 48
Voltage variable range Edc V 2.6 to 4.0 4.0 to 5.8 9.6 to 13.2 12.0 to 16.5 19.2 to 26.4 22.4 to 30.8 38.4 to 52.8
Maximum output current A 12.5 10 4.3 3.5 2.2 1.8 1.1
Minimum output current A 0 0 0 0 0 0 0
Overvoltage threshold2V 4.2 to 5.2 6.0 to 6.9 13.7 to 15.7 17.0 to 19.0 27.0 to 30.5 32.0 to 35.0 55.0 to 60.0
Overcurrent threshold A 13.2 to 15.6 10.5 to 12.5 4.5 to 5.4 3.68 to 4.38 2.3 to 2.75 1.9 to 2.25 1.15 to 1.38
Voltage
stability
Source effect % 0.2max.(0.1typ.)[Within the input voltage range]
Total effect±1.8max.(±0.9typ.)Load effect % 0.4max.(0.2typ.)[0 to 100% load]
Temperature effect % 1.0max.(0.5typ.)[Ambient temperature: –10 to +71°C]
Drift(Time effect) % 0.5max.(0.2typ.)[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Recovery % ±4max.[50 to 100% sudden load change, tr, tf 50µs]
Ripple Ep-p2mV 80max. 80max. 100max. 100max. 150max. 150max. 200max.
Ripple noise Ep-p2mV 120max. 120max. 150max. 150max. 200max. 200max. 300max.
Start up time3ms 500max.(400typ.)/300max.(200typ.)[AC.100/240V]
Hold up time ms 20min.(30typ.)
Maximum load capacitor µF 10000
Auxiliary functions
Indicator display LED(Green) indicates when voltage output is ON.
Overvoltage protection Output voltage shut-down type, recovers upon reset(interval approx.30s)
Overcurrent protection Rectangular type, automatic recovery.
Remote ON-OFF Yes(An internal switch for toggling between on and off is provided.)
Remote sensing Yes
Parallel operation Impossible
Series operation Possible
Current balance No
Output voltage external variable function No
Master slave operation No
Standards
Safety standards UL60950, CSA 60950(C-UL), EN60950(TÜV) approved, Electrical Appliance and Material Safety Law
("DENAN") meet.
Noise terminal voltage FCC-Class B, VCCI-Class B, EN55011-B, EN55022-B meet.
Immunity EN50082-2, EN50082-2, EN61000-4-2, 3, 4, 5, 6, 8, 11 meet.
Input harmonics current requirement EN61000-3-2 meet.
Radiation field intensity FCC-Class FCC-Class B, VCCI-Class B, EN55011-B, EN55022-B meet.
Constructions
External dimensions mm 82×22×124[H×W×L]
Weight g 290max.
Mounting method Can be attached to 2 sides, 3 directions
Case material Frame: Aluminum, circuit board: CEM-3
All specifications are subject to change without notice.
(3/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
RTW50W
WITH COVER TYPE
SHAPES AND DIMENSIONS
Do not insert installation screws more than 6mm into the power supply.
TERMINAL DESIGNATIONS AND FUNCTIONS
Terminal No. Designations and functions
1 AC input terminal(N) Connect to AC.100 to 120V or AC. 200 to 240V input line.
2 AC input terminal(L) Connect to AC.100 to 120V or AC. 200 to 240V input line.
3 Frame ground terminal(G) Connect to earth ground. This is connected to the case.
4 Remote ON-OFF terminals(+RC, –RC) The output voltage can be turned on and off from an external source by inputting the external signal
between these terminals. RC terminals are floating.
5 Remote sensing terminals(+S, –S) These terminals are used to compensate voltage loss from the output terminal to a load.
DC output terminals are shorted with a metal bar.
6 DC output terminal(+, –) Connect to load.
7 Output voltage adjustment trim(V.ADJ)Adjusts output voltage.
Turn clockwise to increase the voltage.
8 Operation indicator LED(Green) This Green LED becomes indicated when voltage is output.
9 Remote ON-OFF switch Turn the remote on/off switch located at the center of the power supply to "Y" (clockwise) to enable
the remote control.
15max. 124
Cover
Label
Cover
82
67.5±0.5
98.5±0.5 6
For mounting 2-M4×0.7
For mounting 2-M3×0.5
105.6±0.5 5
Label
Frame
P.W.B.
Short block
8.5
22
12.8
2-M4×6L
Short piece
(16.9)
(10.7)
(13.1)
(8.4)
(7.62)(6.62)(
39.1)(
8.62)(10.2)
(78.3)
(82)
(77.52)
(22)
7-M3×6L Label
+S
+
S
+RC
RC
G
L
N
Dimensions in mm
±1mm : without specified dimensions
+S
+
S
+RC
RC
G
L
N
1
2
3
4
5
6
7
89
All specifications are subject to change without notice.
(4/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
RTW50W
WITHOUT COVER TYPE
SHAPES AND DIMENSIONS
Do not insert installation screws more than 6mm into the power supply.
TERMINAL DESIGNATIONS AND FUNCTIONS
Terminal No. Designations and functions
1 AC input terminal(N) Connect to AC.100 to 120V or AC. 200 to 240V input line.
2 AC input terminal(L) Connect to AC.100 to 120V or AC. 200 to 240V input line.
3 Frame ground terminal(G) Connect to earth ground. This is connected to the case.
4 Remote ON-OFF terminals(+RC, RC) The output voltage can be turned on and off from an external source by inputting the external signal
between these terminals. RC terminals are floating.
5 Remote sensing terminals(+S, S) These terminals are used to compensate voltage loss from the output terminal to a load.
DC output terminals are shorted with a metal bar.
6 DC output terminal(+, ) Connect to load.
7 Output voltage adjustment trim(V.ADJ)Adjusts output voltage.
Turn clockwise to increase the voltage.
8 Operation indicator LED(Green) This Green LED becomes indicated when voltage is output.
9 Remote ON-OFF switch Turn the remote on/off switch located at the center of the power supply to "Y" (clockwise) to enable
the remote control.
15max. 124
98.5±0.5 6
2-M4×0.7
2-M3×0.5
LabelLabel
Label
105.6±0.5 5
82
67.5±0.5
8.5
22
12.8
+S
+
S
+RC
RC
G
L
N
Label
2-M4×6L
Short piece
Short block
(10.7)
(78.43)
7-M3×6L
(22)
(13.1)
(8.4)
(7.62)(6.62)(
39.1)(
8.62)(10.2)
(82)
(78.98)
P.W.B.
Frame
Dimensions in mm
±1mm : without specified dimensions
+S
+
S
+RC
RC
G
L
N
1
2
3
4
5
6
7
89
All specifications are subject to change without notice.
(5/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
RTW50W
L TYPE(WITHOUT TOP-FACING TERMINAL BLOCK COVER)
SHAPES AND DIMENSIONS
Do not insert installation screws more than 6mm into the power supply.
TERMINAL DESIGNATIONS AND FUNCTIONS
Terminal No. Designations and functions
1 AC input terminal(N) Connect to AC.100 to 120V or AC. 200 to 240V input line.
2 AC input terminal(L) Connect to AC.100 to 120V or AC. 200 to 240V input line.
3 Frame ground terminal(G) Connect to earth ground. This is connected to the case.
4 Remote ON-OFF terminals(+RC, RC) The output voltage can be turned on and off from an external source by inputting the external signal
between these terminals. RC terminals are floating.
5 Remote sensing terminals(+S, S) These terminals are used to compensate voltage loss from the output terminal to a load.
DC output terminals are shorted with a metal bar.
6 DC output terminal(+, ) Connect to load.
7 Output voltage adjustment trim(V.ADJ)Adjusts output voltage.
Turn clockwise to increase the voltage.
8 Operation indicator LED(Green) This Green LED becomes indicated when voltage is output.
9 Remote ON-OFF switch Turn the remote on/off switch located at the center of the power supply to "Y" (clockwise) to enable
the remote control.
4max. 134.5
98.5±0.5 6
2-M4×0.7
2-M3×0.5
LabelLabel
Label
105.6±0.5 5
82
67.5±0.5
8.5
22
12.8
(7)
(7.62)(6.68)(
39.1)(
8.62)(10.2)
(79.21)
(77.9)
UP
+S
+
S
+RC
RC
G
L
N
Label
P.W.B.
Frame
Short piece
Short block
7-M3×6L
2-M4×6L
Dimensions in mm
±1mm : without specified dimensions
+S
+
S
+RC
RC
G
L
N
1
2
3
4
5
6
8
79
All specifications are subject to change without notice.
(6/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
RTW100W TYPE
SHAPES AND DIMENSIONS
1Current rating(maximum output current) is determined for 10 to +40°C. Derating is required when used outside this temperature range.
2Multiply by 1.5 for use at 100 MHz in a temperature range of 10 to 0°C.
3There will be a decrease in output voltage during cold starts in a temperature range of 20 to 0°C. It may take up to three seconds for the voltage to
stabilize.
Part No.
Without cover RTW03-25R RTW05-20R RTW12-8R4 RTW15-6R7 RTW24-4R2 RTW28-3R6 RTW48-2R1
With cover RTW03-25RC RTW05-20RC RTW12-8R4C RTW15-6R7C RTW24-4R2C RTW28-3R6C RTW48-2R1C
L type RTW03-25RL RTW05-20RL RTW12-8R4L RTW15-6R7L RTW24-4R2L RTW28-3R6L RTW48-2R1L
Rated output voltage and current13.3V 25A 5V 20A 12V 8.4A 15V 6.7A 24V 4.2A 28V 3.6A 48V 2.1A
Maximum output power W 82.5 100 100.8 100.5 100.8 100.8 100.8
Input conditions
Input voltage Eac V 85 to 265[Rated: 100-240](AC.90V max.: Derating is 90percent)
Input frequency Hz 47 to 66[Rated: 50-60](Single phase)
Input current A 1.5max./0.75max.[AC.100-120/200-240V](3.3V: 1.2max./0.6max.)
Fuse rating A 3.15[Built-in]
Surge current A 14typ./28typ.[AC.100/240V, 1st surge current, 25°C, cold start]
Leakage current mA 0.45max./0.6max.[AC.100(Electrical Appliance and Material Safety Law)/240V(UL, IEC)]
Power factor 0.99typ./0.93typ.[AC.100/240V]
Efficiency % 100V 79typ. 83typ. 84typ. 85typ. 85typ. 85typ. 85typ.
% 200V 81typ. 85typ. 86typ. 87typ. 87typ. 87typ. 88typ.
Output characteristics
Output voltage Edc V 3.3 5 12 15 24 28 48
Voltage variable range Edc V 2.6 to 4.0 4.0 to 5.8 9.6 to 13.2 12.0 to 16.5 19.2 to 26.4 22.4 to 30.8 38.4 to 52.8
Maximum output current A 25 20 8.4 6.7 4.2 3.6 2.1
Minimum output current A 0 0 0 0 0 0 0
Overvoltage threshold V 4.2 to 5.2 6.0 to 6.9 13.7 to 15.7 17.0 to 19.0 27.0 to 30.5 32.0 to 35.0 55.0 to 60.0
Overcurrent threshold A 26.2 to 33.7 21 to 25 8.8 to 10.5 7.03 to 9.04 4.41 to 5.25 3.78 to 4.86 2.2 to 2.62
Voltage
stability
Source effect % 0.2max.(0.1typ.)[Within the input voltage range](3.3V: 10mV max./5mV typ.)
Total effect±1.8max.(±0.9typ.)Load effect % 0.4max.(0.2typ.)[0 to 100% load](3.3V: 20mV max./10mV typ.)
Temperature effect % 1.0max.(0.5typ.)[Ambient temperature: 10 to +71°C]
Drift(Time effect) % 0.5max.(0.2typ.)[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Recovery % ±4max.[50 to 100% sudden load change, tr, tf 50µs]
Ripple Ep-p2mV 80max. 80max. 100max. 100max. 150max. 150max. 200max.
Ripple noise Ep-p2mV 120max. 120max. 150max. 150max. 200max. 200max. 300max.
Start up time3ms 500max.(420typ.)/300max.(210typ.)[AC.100/240V]
Hold up time ms 20min.(30typ.)/30min.(40typ.)[AC.100/240V]
Maximum load capacitor µF 10000
Auxiliary functions
Indicator display LED(Green) indicates when voltage output is ON.
Overvoltage protection Output voltage shut-down type, recovers upon reset(interval approx.30s)
Overcurrent protection Winker operation, automatic recovery.
Overheat protection No
Remote ON-OFF Yes(An internal switch for toggling between on and off is provided.)
Remote sensing Yes
Parallel operation Impossible
Series operation Possible
Current balance No
Output voltage external variable function No
Master slave operation No
Standards
Safety standards UL60950, CSA 60950(C-UL), EN60950(TÜV) approved, Electrical Appliance and Material Safety Law
("DENAN") meet.
Noise terminal voltage FCC-Class B, VCCI-Class B, EN55011-B, EN55022-B meet.
Immunity EN50082-2, EN50082-2, EN61000-4-2, 3, 4, 5, 6, 8, 11 meet.
Input harmonics current requirement EN61000-3-2 meet.
Radiation field intensity FCC-Class FCC-Class B, VCCI-Class B, EN55011-B, EN55022-B meet.
Constructions
External dimensions mm 82×25×160[H×W×L]
Weight g 450max.
Mounting method Can be attached to 2 sides, 3 directions
Case material Frame: Aluminum, circuit board: CEM-3
All specifications are subject to change without notice.
(7/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
RTW100W
WITH COVER TYPE
SHAPES AND DIMENSIONS
Do not insert installation screws more than 6mm into the power supply.
TERMINAL DESIGNATIONS AND FUNCTIONS
Terminal No. Designations and functions
1 AC input terminal(N) Connect to AC.100 to 120V or AC. 200 to 240V input line.
2 AC input terminal(L) Connect to AC.100 to 120V or AC. 200 to 240V input line.
3 Frame ground terminal(G) Connect to earth ground. This is connected to the case.
4 Remote ON-OFF terminals(+RC, RC) The output voltage can be turned on and off from an external source by inputting the external signal
between these terminals. RC terminals are floating.
5 Remote sensing terminals(+S, S) These terminals are used to compensate voltage loss from the output terminal to a load.
DC output terminals are shorted with a metal bar.
6 DC output terminal(+, ) Connect to load.
7 Output voltage adjustment trim(V.ADJ)Adjusts output voltage.
Turn clockwise to increase the voltage.
8 Operation indicator LED(Green) This Green LED becomes indicated when voltage is output.
9 Remote ON-OFF switch Turn the remote on/off switch located at the center of the power supply to "Y" (clockwise) to enable
the remote control.
15max. 160
Label
Cover
Frame
Short block
Label
82
69.7±0.5
135.3±0.5 7.6
For mounting 2-M4×0.7
For mounting 2-M3×0.5
121.7±0.5 20.5
Label
P.W.B.
6.3
25
12.1
+S
+
S
+RC
RC
G
L
N
Short piece
2-M4×6L
(17.1)
(10.7)
(8.4)
(7.62)(6.12)(
39.1)(
8.62)(10.2)
(6.4)
(78.3)
(78.55)
(13.1)
7-M3×6L
TDK
Dimensions in mm
±1mm : without specified dimensions
+S
+
S
+RC
RC
G
L
N
TDK
8
7
9
1
2
3
4
5
6
All specifications are subject to change without notice.
(8/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
RTW100W
WITHOUT COVER TYPE
SHAPES AND DIMENSIONS
Do not insert installation screws more than 6mm into the power supply.
TERMINAL DESIGNATIONS AND FUNCTIONS
Terminal No. Designations and functions
1 AC input terminal(N) Connect to AC.100 to 120V or AC. 200 to 240V input line.
2 AC input terminal(L) Connect to AC.100 to 120V or AC. 200 to 240V input line.
3 Frame ground terminal(G) Connect to earth ground. This is connected to the case.
4 Remote ON-OFF terminals(+RC, RC) The output voltage can be turned on and off from an external source by inputting the external signal
between these terminals. RC terminals are floating.
5 Remote sensing terminals(+S, S) These terminals are used to compensate voltage loss from the output terminal to a load.
DC output terminals are shorted with a metal bar.
6 DC output terminal(+, ) Connect to load.
7 Output voltage adjustment trim(V.ADJ)Adjusts output voltage.
Turn clockwise to increase the voltage.
8 Operation indicator LED(Green) This Green LED becomes indicated when voltage is output.
9 Remote ON-OFF switch Turn the remote on/off switch located at the center of the power supply to "Y" (clockwise) to enable
the remote control.
15max. 160
135.3±0.5 7.6
2-M4×0.7
2-M3×0.5
LabelLabel
LabelLabel
121.7±0.5 20.5
82
69.7±0.5
6.3
24.2
12.1
+S
+
S
+RC
RC
G
L
N
Short block
FrameP.W.B.
2-M4×6L
Short piece
(17.1)
(10.7)
(78.55)
(13.1)
(8.4)
(7.62)(6.12)(
39.1)(
8.62)(10.2)
(78.3)
7-M3×6L
Dimensions in mm
±1mm : without specified dimensions
+S
+
S
+RC
RC
G
L
N
8
7
9
1
2
3
4
5
6
All specifications are subject to change without notice.
(9/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
RTW100W
L TYPE(WITHOUT TOP-FACING TERMINAL BLOCK COVER)
SHAPES AND DIMENSIONS
Do not insert installation screws more than 6mm into the power supply.
TERMINAL DESIGNATIONS AND FUNCTIONS
Terminal No. Designations and functions
1 AC input terminal(N) Connect to AC.100 to 120V or AC. 200 to 240V input line.
2 AC input terminal(L) Connect to AC.100 to 120V or AC. 200 to 240V input line.
3 Frame ground terminal(G) Connect to earth ground. This is connected to the case.
4 Remote ON-OFF terminals(+RC, RC) The output voltage can be turned on and off from an external source by inputting the external signal
between these terminals. RC terminals are floating.
5 Remote sensing terminals(+S, S) These terminals are used to compensate voltage loss from the output terminal to a load.
DC output terminals are shorted with a metal bar.
6 DC output terminal(+, ) Connect to load.
7 Output voltage adjustment trim(V.ADJ)Adjusts output voltage.
Turn clockwise to increase the voltage.
8 Operation indicator LED(Green) This Green LED becomes indicated when voltage is output.
9 Remote ON-OFF switch Turn the remote on/off switch located at the center of the power supply to "Y" (clockwise) to enable
the remote control.
UP
4max. 171.5
135.3±0.5
7.6
2-M4×0.7
2-M3×0.5
LabelLabel
LabelShort piece
7-M3×6L
2-M4×6L
121.7±0.5 20.5
82
69.7±0.5
6.3
24.2
12.1
+S
+
S
+RC
RC
G
L
N
(7)
(7.62)(6.16)(
39.1)(
8.62)(10.2)
(78.75)
(78.15)
Short block
Label
P.W.B.
Frame
Dimensions in mm
±1mm : without specified dimensions
+S
+
S
+RC
RC
G
L
N
7
8
9
1
2
3
4
5
6
All specifications are subject to change without notice.
(10/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
BLOCK DIAGRAMS
COMMON SPECIFICATIONS
INSTALLATIONS
Temperature and humidity
Temperature range
Operating(°C) 10 to +71
Operating available(°C) 20 to 10
Storage(°C) 30 to +75
Humidity range Operating(%)RH 10 to 95[Maximum wet-bulb temperature: 35°C, without dewing]
Storage(%)RH
Vibration and shock
Vibration 5 to 10Hz All amplitude 10mm[3 directions, each 1h, Sweep time 10min]
10 to 200Hz Acceleration 19.6m/s2(2G)[3 directions, each 1h, Sweep time 10min]
Shock Acceleration
50W: 392m/s2(40G)[3 directions, each 3 times, Non-operation]
100W: 196m/s2(20G)[A instllation]
100W: 588m/s2(60G)[B, C instllation]
Pulse duration 11±5ms
Withstand voltage and insulation resistance
Withstand voltage
Input terminal to ground(G) Eac: 2.0kV, 1min[Normal temperature, normal humidity, cutout current 10mA]
Input terminal to output terminal Eac: 3.0kV, 1min[Normal temperature, normal humidity, cutout current 10mA]
Output terminal to ground(G) Eac: 500V, 1min[Normal temperature, normal humidity, cutout current 20mA]
Insulation resistance
Input terminal to ground(G)
Edc: 500V, 100M min. [Normal temperature, normal humidity]Input terminal to output terminal
Output terminal to ground(G)
L
N
+S
S
DC output
Output rectifying
and smoothing
circuit
Enable/disable
switch
Input
filter
circuit
Input
rectifier
circuit
Surge
current
limiting
circuit
Power
switching
circuit
Overcurrent
detection
circuit
Control circuit
Boost-up
circuit
PFC control
circuit
Overvoltage
detection
circuit
+RC
RC
Output
voltage
detection
circuit
+
AC input
(A) (B)(
C)
All specifications are subject to change without notice.
(11/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
OUTPUT POWER-AMBIENT TEMPERATURE(DERATINGS)
50W WITH COVER TYPE
50W WITHOUT COVER, L TYPE
100W WITH COVER TYPE
100W WITHOUT COVER, L TYPE
INPUT VOLTAGE DERATING
INSTALLATIONS
There are (B), (C), (D), and (E) besides standard installation
method (A) when the power supply is mounted on the device.
Because heat shuts oneself up internally in the power supply, the
installation of (D) and (E) cannot be used.
Please use the installation of (A), (B), and (C) within the range of
DERATING CURVE.
20
10
40
60
80
100
Ambient temperature(˚C)
Output power(%)
–20 –10 0 10 20 30 40 50 60 71
(A)
(B), (C)
Available operating range
(outside of warranty)
10 10 20 30 40 50 60 7120 0
100
80
70
60
40
0
20
Output power(%)
Ambient temperature(˚C)
(B),(C) (A)
Available operating range
(outside of warranty)
20
10
40
60
80
100
Ambient temperature(˚C)
Output power(%)
50
20 10 0 10 20 30 40 50 60 71
(A)
(B), (C)
Available operating range
(outside of warranty)
10 10 20 30 40 50 60 65 7120 0
100
80
60
40
0
20
Output power(%)
Ambient temperature(˚C)
(B),(C)
(A)
Available operating range
(outside of warranty)
100 110 120 130 140 26585 90
100
80
90
60
40
0
20
Output power(%)
Input voltage Eac(V)
(B),(C)
(A)
(B)(E)
(A) Standard installation
(C)(
D)
All specifications are subject to change without notice.
(12/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
REMOTE SENSING
Remote Sensing compensates to provide stability at the load ter-
minal when voltage drop in the line between the power supply and
the load causes instability. Remote sensing is possible if the volt-
age drop per wire between the output and load terminals is 0.25V
max. for 5.0V models and 0.4V max. for 12 to 48V models.
Make sure that the power supplys output voltage and power
remains within the range of the output specifications. Pulse loads
and other situations where sudden changes in the load can occur
may not conform to the dynamic load change specifications.
Take out the short-circuit plates of the +S/+ terminal and the S/
terminal and wire them as shown in the figure below. The sensing
lines must be either shielded or twisted (The recommended length
is 5m (max.)).
In case of parasitic oscillation or overvoltage protection malfunc-
tion too easily, install an external electrolytic capacitor, rated 470µF
min. between the +OUT, +S and OUT, S terminals.
REMOTE ON-OFF
Turn the remote on/off switch located at the center of the power
supply to "Y" (clockwise) to enable the remote control.
The output voltage can be turned on and off from an external
source by inputting the signal indicated below between the remote
on/off terminals (+RC and RC).
Output voltage is turned on when the level is high between the
+RC and RC terminals (external voltage application of 4.5 to
24.5V).
Output voltage is turned off when the level is low between the +RC
and RC terminals (short or terminal voltage of 0 to 0.8V).
Use an external resistor (1.5k) when applying an external volt-
age of 12.5-24.5V.
±RC terminals are insulated from AC input terminals and the DC
output terminals.
Insulation between the ±RC terminals and the output conforms to
the common specifications (Output to case). Withstand voltage
between AC input terminals and ±RC terminals conforms to the
common specifications (Input to case).
INSULATION AND WITHSTAND VOLTAGE TESTS
The insulation and withstand voltage tests may cause deteriora-
tion. Care must be taken for execution of the tests. The potential
must be equal among input, output, and FG (frame ground) termi-
nals. It is preferable to use testers which gently start up at the test-
ON and automatically discharge charging energy at the test-OFF.
Manual discharging after the tests should be through a resistor
around 100k to 1M (Do not perform discharging at low imped-
ance. It may cause deterioration.).
In any case, take full countermeasures for electric-shock preven-
tion.
POWER SUPPLY TERMINAL CONNECTION AT INSULATION
AND WITHSTAND VOLTAGE TESTS
Short output or input terminals.
CONNECTIONS BETWEEN TESTERS AND POWER SUPPLY
AT INSULATION AND WITHSTAND VOLTAGE TESTS
For connections between the testers and the power supply body,
couple the tester terminals at the corresponding locations listed
below before executing the tests.
Twisted(Stranded wire)
+
+
+
+S
S
Load
+S
+
S
+RC
RC
G
L
N
Input and output terminals
Turn the internal switch to "Y."
RSW
NY
External
voltage
Test conditions Withstand voltage tester Insulation tester
+ terminal terminal + terminal terminal
Input-to-output
withstand voltage 13——
Input-to-FG
withstand voltage 12——
Output-to-FG
withstand voltage 32——
Input-to-FG
insulation ——12
Input-to-output
insulation ——13
Output-to-FG
insulation ——32
+S
+
S
+RC
RC
G
L
N
3 Output terminal
2 FG
1 Input termina
All specifications are subject to change without notice.
(13/13)
001-03 / 20031126 / ea111_rtw.fm
Power Supplies R Series RTW(50 to 100W)
AC Input
Single Output, General-Purpose UL/CSA/TÜV Approved
PRECAUTIONS
When using this unit, make sure that the ambient temperature of
the power supply is within the operating temperature range. The
"ambient temperature of the power supply" refers to the temper-
ature near the power supply inside the device in which the unit is
installed.
If natural cooling is used, install the unit in such a way that a
thermal convection is created. Additionally, space the power
supply at least 10 mm away from other components on all sides.
Make sure to choose input/output wiring and noise filters that
can safely accommodate their respective current capacities.
If the power supply is not used for extended periods of time, we
recommend that you apply input voltage for about one hour
every two years to maintain the capacitors performance.
When power supplies are used serially, the rated current will be
limited by the power supply with the lowest rated current. Also
make sure to connect a reverse voltage protection diode (With-
stand voltage: twice that of the combined output voltage. For-
ward current: twice that of the output current. Forward voltage
drop: as small as possible) to prevent damage to the interior
components caused by reverse voltage.
The materials used in these products are free of designated bro-
mine flameproof materials (PBDPEs and PBBs).
Specific ODS has not been used in the production of these prod-
ucts.