POWER
DA12-M Series
12 Watts
Total Power: 12 Watts
Input Voltage: 90 - 264 Vac
# of Outputs: Single
SPECIAL FEATURES
5 V and 12 V versions
Medical and ITE Safeties
Switching wallmount
power supply
Available in interchangeable &
xed ac plug congurations
CE Mark EMC, LVD & ErP 2011
Universal AC input
Fully regulated output
Overload and short circuit
protection
Thermal protection
Energy Star and CeC compliant
Efciency level V
Constant voltage
High MTBF
Built in EMI lter
(CISPR 22 Class B)
SAFETY
UL 60950, 60601-1
cUL 60950, 60601-1
TUV 60950-1, 60601-1
AS/NZS 60950-1, 60601-1
CB Certicate and report
CE EMC, LVD & ErP 2011
for EU & UK versions
PSE Denan
CCC <2000M, No Tropical
Electrical Specications
Input
Input range: 90 - 264 Vac (wide range)
Frequency: 47 - 63Hz
Inrush current: 28 A @ 264 Vac
Input current: 0.25 A rms @ 120 Vac; 0.15 A @ 240 Vac
EMI/RFI: FCC Part 15, Subpart B Class B & EN55022
(CISPR 22) Class B
Safety ground leakage current: 100 μA @ 50/60 Hz, 264 Vac input
Output
Voltage (Vo): 5.0 V and 12.0 V
Voltage regulation: ± 5% @ constant voltage mode
Maximum Power (Po): 12 W for 12 V models, 10 W for 5 V models
Hold-up time: 10 ms. typical at full load @ 230 Vac
Overvoltage protection: Non-latching type
Overload protection: Output shortcircuit protection auto recover
Overload protected @ 150% above maximum rating
Overtemperature protection: Auto recovery
Output cable/connector
barrel polarity:
DC cable with 2.5 mm x 5.5mm barrel plug, 2.1 mm x 5.5 mm
available on DC multi-plug version. For others please contact factory.
DC plug center +v
DC plug outer -v
Data Sheet
DA12-M Series Data Sheet
Environmental Specications
Operating temperature: 0 ° to +40 °C ambient
Storage temperature: -40 °C to +85 °C
Electromagnetic susceptibility: Designed to meet EN55024
Humidity: Operating; non-condensing 5% to 95% RH
Vibration:
Frequency/PSD: 5 - 350 Hz 0.0001 g2/Hz
350 - 500 Hz - 6dB/Oct.
500 Hz 0.00005 g2/Hz
Acceleration: 0.21 gRMS
Duration: 20 min per second
AC Plug Conguration for Fixed Plug
U.S. 2-prong US
Europe 2-prong EU
United Kingdom 3-prong UK
Australia 2-prong AU
AC Plug Conguration for Interchangeable Plug
U.S. 2-prong DA-US
Europe 2-prong DA-EU
United Kingdom 3-prong DA-UK
Australia 2-prong DA-AU
C8 - 2 receptacle DA-C8
Japan 2-prong DA-JP
China 2-prong DA-CH
Korea 2-prong DA-KR
DA12-M Series Data Sheet
Mechanical Drawings
2.36”
(60)
1.78”
(45,3)
1.99”
(50,6)
1.10”
(28) 2.65”
(67,3)
0.63”
(16)
CONNECTOR PIN-OUT DETAIL
(-)
(+)
59”
(1500)
CONNECTOR PIN-OUT DETAIL
(+)
(-)
2.36”
(60)
2.8”
(71,4)
2.14”
(54,3)
1.10”
(28
±
0,3)
0.67”
(17,1)
59
(1500)
DA12-XXXUS-M
DA12-XXXAU-M
DA12-M Series Data Sheet
Mechanical Drawings
59
(1500)
2.36”
(60)
3.22”
(82)
1.10”
(28)
0.685”
(17,4)
0.744”
(18,9)
CONNECTOR PIN-OUT DETAIL
(+)
(-)
CONNECTOR PIN-OUT DETAIL
(-)
(+)
2.36”
(60)
1.90”
(48,3)
0.893”
(22,7)
1.98”
(50.2)
59”
(1500)
DA12-XXXEU-M
DA12-XXXUK-M
DA12-M Series Data Sheet
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ± .02”.
3. Weight: 0.25 lb/0.114 kg
4. Warranty: 2 years
Mechanical Drawings
59”
(1500)
2.36
(60)
1.10”
(28)
2.06”
(52.22)
1.58”
(40.18)
DA-US DA-UK DA-EU DA-AU
DA-CH DA-JP DA-KR DA-C8
*Can be inserted straight or 90˚ *Can be inserted straight or 90˚
*Can be inserted straight or 90˚ *Can be inserted straight or 90˚
DA12-MP Interchangeable Plug Adapter
DA12-M Series Data Sheet
WORLDWIDE OFFICES
Americas
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
For more information: www.artesyn.com/power
For support: productsupport.ep@artesyn.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Artesyn
Embedded Technologies assumes no responsibility, and disclaims all liability for damages resulting from use of
this information or for any errors or omissions. Artesyn Embedded Technologies, Artesyn and the Artesyn
Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other
names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners.
© 2014 Artesyn Embedded Technologies, Inc.
www.artesyn.com
DA12-M Series-DS 11.13.14
Ordering Information - DA12 Adapter
Model Number Maximum Power Output Voltage Minimum Load Maximum Load Regulation2Ripple P/P
(PARD)3
DA12-120US-M 12 W 12.0 V 0.2 A 1.0 A ± 5% 120 mV
DA12-120EU-M 12 W 12.0 V 0.2 A 1.0 A ± 5% 120 mV
DA12-120UK-M 12 W 12.0 V 0.2 A 1.0 A ± 5% 120 mV
DA12-120AU-M 12 W 12.0 V 0.2 A 1.0 A ± 5% 120 mV
DA12-120MP-M* 12 W 12.0 V 0.2 A 1.0 A ± 5% 120 mV
DA12-120MP-M2.1** 12 W 12.0 V 0.2 A 1.0 A ± 5% 120 mV
DA12-050US-M 10 W 5.0 V 0.2 A 2.0 A ± 5% 50 mV4
DA12-050EU-M 10 W 5.0 V 0.2 A 2.0 A ± 5% 50 mV4
DA12-050UK-M 10 W 5.0 V 0.2 A 2.0 A ± 5% 50 mV4
DA12-050AU-M 10 W 5.0 V 0.2 A 2.0 A ± 5% 50 mV4
DA12-050MP-M* 10 W 5.0 V 0.2 A 2.0 A ± 5% 50 mV4
DA12-050MP-M2.1** 10 W 5.0 V 0.2 A 2.0 A ± 5% 50 mV4
DA12-050MP-M402*** 10 W 5.0 V 0.2 A 2.0 A ± 5% 50 mV
* Interchangeable version - AC Plugs must be purchased separately to be used with DA12-120MP-M and DA12-050MP-M
** 2.1 mm x 5.5 mm barrel plug
*** μ USB Connector
Ordering Information - DA12 Interchangeable Plug
Model Number
DA-US DA-C8
DA-EU DA-JP
DA-UK DA-CH
DA-AU DA-KR
DA-All (Includes DA-US, DA-EU, DA-UK, and DA-AU)
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 mHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
4. DA12-050XX model power supplies will operate with no-load, However under 0.1A Load Output ripple will exceed 50mV.