Basic Force Sensors TBF Series, Compensated/Unamplified 1 bar to 10 bar | 100 kPa to 1 MPa | 15 psi to 150 psi Millivolt Analog Output 32315675 Issue A Datasheet FEATURES * Cost-effective sensor with many options * Compensated/unamplified * Wide operating temperature range (0 C to 50 C [32 F to 122 F]) * Low power consumption allows for potential use in battery operated applications * Stable offset voltage * Not sensitive to mounting orientation * Small package size [7 mm x 7 mm x 3,89 mm] * RoHS2 compliance POTENTIAL APPLICATIONS DESCRIPTION Honeywell's TBF Series Force Sensors are small flush diaphragm pressure sensors designed for customers who require a simple device for applications where media compatibility and low trapped volume are important. The TBF Series has a precisely controlled diaphragm height, making these products useful in applications where force is applied by a flexible membrane to the sensor, such as infusion pumps. The sensor is internally unamplified, providing infinite resolution and allowing customers to do their own amplification in order to make use of the maximum resolution of the bare sensor output, leveraging any algorithm needed for the application. The sensor is internally temperature compensated and calibrated. VALUE TO CUSTOMERS * Smallest package size in its class (7 mm x 7 mm x 3,89 mm) simplifies placement on crowded PCBs * Widest pressure (1 bar to 10 bar |100 kPa to 1 MPa | 15 psi to 150 psi) enables choice of optimum pressure range to maximize sensitivity * Many different pressure ranges improve resolution and system accuracy * Tight accuracy specification of 0.15 %FSS provides user with enhanced accuracy in the application * Reliable supply chain * Fast response for quotes and samples * Designed to Six Sigma standards * Manufacturing excellence * Supports Lean manufacturing Sensing and Productivity Solutions Medical * Drug delivery systems * Infusion pumps * Kidney dialysis machines * Robotics * Syringe pumps * Wearables PORTFOLIO The TBF Series joins the 1865 Series, FSG Series, FSS Series, FSS-SMT Series and FSA Series. Basic Force Sensors, TBF Series, Compensated/Unamplified Table 1. Absolute Maximum Ratings1 Characteristic Min. Max. Unit Supply voltage (Vsupply)2 -12.0 12.0 Vdc -40 [-40] 125 [257] C [F] Storage temperature Soldering time peak reflow temperature 10 s max. at 240 C [464 F] Absolute maximum ratings are the extreme limits the device will withstand without damage. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure. 1 2 Table 2. Operating Specifications Characteristic Min. Typ. Max. Unit 1.5 5.0 12.0 Vdc - 0.6 1 mA Operating temperature range3 0 [32] -- 50 [122] C [F] Compensated temperature range4 0 [32] -- 50 [122] C [F] -- 2.5 - kOhm Supply voltage (Vsupply)1, 2 Supply current (at 5.0 Vdc supply) Output resistance Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage. 2 Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure. 3 Operating temperature range: The temperature range over which the sensor will produce an output proportional to force. 4 Compensated temperature range: The temperature range over which the sensor will produce an output proportional to force within the specified performance limits. 1 Table 3. Environmental Specifications Characteristic Parameter Humidity 0 %RH to 95 %RH, non-condensing Vibration 15 g, 10 Hz to 2 kHz Shock 100 g, 6 ms duration Life1 Solder reflow 1 million pressure cycles min. J-STD-020-D, MSL 1 (unlimited shelf life when stored at less than 30 C and 85 %RH) Life may vary depending on specific application in which sensor is utilized. 1 CAUTION PRODUCT SENSING SURFACE DAMAGE * The sensing surface of the sensor is composed of a tough silicone gel. Ensure that the sensing surface is not used with media incompatible with silicones. * Ensure that the sensing surface does not come into contact with sharp or hard objects. Failure to comply with these instructions may result in product damage. NOTICE In order for the TBF Series sensors to provide a linear and repeatable output, ensure the entire top surface of the gel is exposed to a uniform pressure. The silicone gel allows direct contact with many liquids or the gel may be protected with a thin, compliant membrane. 2 Sensing and Productivity Solutions Basic Force Sensors, TBF Series, Compensated/Unamplified Table 4. Sensor Pressure Type Pressure Type Description Output is proportional to the difference between applied pressure and atmospheric (ambient) pressure. Reference pressure is atmospheric pressure. Gage Table 5. Material Composition Component Description Cover high temperature polyamide Substrate not exposed - protected by silicone gel Sensing surface silicone gel Pmin. Pmax. Full Scale Span3 (mV/V) Offset2 (mV/V) Unit Pressure Accuracy1 (%FSS) Pressure Range Overpressure Pressure Range Order Code (see Figure 1) Table 6. Pressure Range Specifications for 1 bar to 10 bar Thermal Effect on Offset4 (%FSS) Thermal Effect on Span5 (%FSS) Min. Nom. Max. 0 C to 50 C 0 C to 50 C Gage 001BG 0 1 bar 4 0.5 0.3 4.90 5.10 5.30 1.0 1.0 1.6BG 0 1.6 bar 4 0.5 0.3 7.84 8.15 8.48 1.0 1.0 2.5BG 0 2.5 bar 8 0.5 0.15 6.10 6.35 6.59 1.0 0.75 004BG 0 4 bar 10 0.5 0.075 5.57 5.80 6.04 1.0 0.75 006BG 0 6 bar 17 0.5 0.075 5.08 5.30 5.54 0.75 0.75 010BG 0 10 bar 17 0.5 0.075 8.47 8.85 9.22 0.50 0.75 Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 C [77 F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 2 Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as "null" or "zero". 3 Full Scale Span: The algebraic difference between the output signal measured at the maximum and minimum limits of the pressure range (see Figure 1). 4 Thermal effect on offset: The deviation in offset due to changes in temperature over the compensated temperature range, relative to offset measured at 25 C. 5 Thermal effect on span: The deviation in full scale span due to changes in temperature over the compensated temperature range, relative to full scale span measured at 25 C. 1 Sensing and Productivity Solutions 3 Basic Force Sensors, TBF Series, Compensated/Unamplified Pmin. Pmax. Pressure Accuracy1 (%FSS) Unit Full Scale Span3 (mV/V) Offset2 (mV/V) Pressure Range Overpressure Pressure Range Order Code (see Figure 1) Table 7. Pressure Range Specifications for 100 kPa to 1 MPa Min. Thermal Effect on Offset4 (%FSS) Thermal Effect on Span5 (%FSS) Nom. Max. 0 C to 50 C 0 C to 50 C Gage 100KG 0 100 kPa 400 0.5 0.3 4.90 5.10 5.30 1.0 1.0 160KG 0 160 kPa 400 0.5 0.3 7.84 8.15 8.48 1.0 1.0 250KG 0 250 kPa 800 0.5 0.15 6.10 6.35 6.59 1.0 0.75 400KG 0 400 kPa 1000 0.5 0.075 5.57 5.80 6.04 1.0 0.75 600KG 0 600 kPa 1700 0.5 0.075 5.08 5.30 5.54 0.75 0.75 001GG 0 1 MPa 1.70 0.5 0.075 8.47 8.85 9.22 0.50 0.75 Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 C [77 F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 2 Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as "null" or "zero". 3 Full Scale Span: The algebraic difference between the output signal measured at the maximum and minimum limits of the pressure range (see Figure 1). 4 Thermal effect on offset: The deviation in offset due to changes in temperature over the compensated temperature range, relative to offset measured at 25 C. 5 Thermal effect on span: The deviation in full scale span due to changes in temperature over the compensated temperature range, relative to full scale span measured at 25 C. 1 Full Scale Span3 (mV/V) Offset2 (mV/V) Pressure Accuracy1 (%FSS) Pmin. Pmax. Overpressure Pressure Range Unit Pressure Range Order Code (see Figure 1) Table 8. Pressure Range Specifications for 15 psi to 150 psi Min. Thermal Effect on Offset4 (%FSS) Thermal Effect on Span5 (%FSS) Nom. Max. 0 C to 50 C 0 C to 50 C Gage 015PG 0 15 psi 60 0.5 0.3 5.06 5.25 5.49 1.0 1.0 030PG 0 30 psi 115 0.5 0.15 5.05 5.25 5.45 1.0 0.75 060PG 0 60 psi 145 0.5 0.075 5.76 6.00 6.24 1.0 0.75 100PG 0 100 psi 245 0.5 0.075 5.83 6.10 6.36 0.75 0.75 150PG 0 150 psi 245 0.5 0.075 8.65 9.15 9.55 0.50 0.75 Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 C [77 F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 2 Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as "null" or "zero". 3 Full Scale Span: The algebraic difference between the output signal measured at the maximum and minimum limits of the pressure range (see Figure 1). 4 Thermal effect on offset: The deviation in offset due to changes in temperature over the compensated temperature range, relative to offset measured at 25 C. 5 Thermal effect on span: The deviation in full scale span due to changes in temperature over the compensated temperature range, relative to full scale span measured at 25 C. 1 4 Sensing and Productivity Solutions Basic Force Sensors Series, Compesated/Unamplified BasicTBF Force Sensors, TBF Series, Compensated/Unamplified Product Nomenclature Figure 1. Nomenclature and Order Guide For example, TBFLPNS150PGUCV defines a TBF Series Basic Force Sensor, Leadless SMT package, low-profile pressure port, silicone gel interface, 0 psi to 150 psi gage pressure range, unamplified output, compensated, constant supply voltage. TBF L PN S 150PG U C V Supply Voltage Series V Constant TBF Basic force sensor Compensation Package L Leadless SMT (Surface Mount Technology) C Compensated Output Pressure Port PN Low-profile U Unamplified port Pressure Range 1 bar to 10 bar Gage 100 kPa to 1 MPa Gage 15 psi to 150 psi Gage 100KG 0 kPa to 100 kPa 015PG 0 psi to 15 psi 1.6BG 0 bar to 1.6 bar 160KG 0 kPa to 160 kPa 030PG 0 psi to 30 psi 001BG 0 bar to 1 bar Gel Coating Option 2.5BG 0 bar to 2.5 bar 250KG 0 kPa to 250 kPa 060PG 0 psi to 60 psi 004BG 0 bar to 4 bar S Silicone gel interface 400KG 0 kPa to 400 kPa 100PG 0 psi to 100 psi 600KG 0 kPa to 600 kPa 150PG 0 psi to 150 psi 010BG 0 bar to 10 bar 001GG 0 MPa to 1 MPa 006BG 0 bar to 6 bar Figure 2. Leadless SMT Package Dimensional Drawings (For reference only: mm [in].) Sensor 7 [0.276] Mounting Pad Layout 1 [0.039] 3,89 [0.153] 6,5 [0.26] 7 [0.276] 1 6 3,5 [0.138] 2,54 [0.100] 5 2,5 Typ. [0.098] 2 2,50 [0.098] 3 1,27 [0.050] 008302-1-EN IL50 January 2016 Copyright (c) 2016 Honeywell International Inc. All Rights Reserved. 4 Function analog 7,62 [0.300] 1,02 [0.040] 3,5 [0.138] Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Vs NC Vo- GND NC Vo+ Sensing and Productivity Solutions 5 ADDITIONAL INFORMATION The following associated literature is available at sensing.honeywell.com: * Product Range Guide * Product Line Guide WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. * Product Installation Instructions * Technical Information: - Output Signal Adjustment and Temperature Compensation for Honeywell Basic Force Sensors, TBF Series, Compensated/Unamplified WARNING MISUSE OF DOCUMENTATION * * The information presented in this datasheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Warranty/Remedy Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. To learn more about Honeywell Sensing and Productivity Solutions' products, call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Sensing and Productivity Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 32315675-A-EN IL50 January 2016 (c) 2016 Honeywell International Inc. All rights reserved.