www.clare.com
DS-LCA110L-R03 1
LCA110L
RoHS
2002/95/EC e3
Pb
Single Pole, Normally Open
OptoMOS® Relay
Applications
Features
Parameter Ratings Units
Blocking Voltage 350 VP
Load Current 120 mA
Max RON 35
Built-in Current Limiting
3750Vrms Input/Output Isolation
Low Drive Power Requirements
(TTL/CMOS Compatible)
No Moving Parts
High Reliability
Arc-Free With No Snubbing Circuits
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Small 6-Pin Package
Flammability Classification Rating: V-0
Surface Mount, Tape & Reel Version Available
Telecommunications
Telecom Switching
Tip/Ring Circuits
Modem Switching (Laptop, Notebook, Pocket Size)
Hook Switch
Dial Pulsing
Ground Start
Ringing Injection
Instrumentation
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
Medical Equipment—Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
Description
Pin Configuration
Switching Characteristics of
Normally Open (Form A) Devices
The LCA110L is a normally open (1-Form-A) solid
state relay that uses optically coupled MOSFET
technology to provide 3750Vrms of input to output
isolation. Its efficient MOSFET switches and
photovoltaic die use Clare’s patented OptoMOS
architecture. A highly efficent, optically coupled
GaAIAs infrared LED controls the output.
Use the LCA110L to replace mechanical relays,
and gain the superior reliability associated with
semiconductor devices, which, because they have no
moving parts, can offer faster, bounce-free switching
in a more compact surface mount or through-hole
package.
Approvals
Ordering Information
Part # Description
LCA110L 6 Pin DIP (50/Tube)
LCA110LS 6 Pin Surface Mount (50/Tube)
LCA110LSTR 6 Pin Surface Mount (1000/Reel)
Form-A
IF
ILOAD
10%
90%
ton toff
1
3
2
4
5
6
+ Control
– Control
NC
Load
Do Not Use
Load
AC/DC Configuration
+ Load
– Load
1
3
2
4
5
6
+ Control
– Control
NC
DC Only Configuration
UL Recognized Component: File E76270
CSA Certified Component: Certificate 1175739
EN/IEC 60950-1 Certified Component:
TUV Certificate B 09 07 49410 004
www.clare.com
2R03
LCA110L
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Ratings Units
Blocking Voltage 350 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
Isolation Voltage, Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / °C
2 Derate linearly 6.67 mW / °C
Absolute Maximum Ratings @ 25°C
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current, Continuous
AC/DC Configuration -I
L--
120 mA
DC Configuration 200
Load Current Limiting, AC/DC Configuration IF=2mA, VL=8V ICL 130 170 210 mA
On-Resistance 1
AC/DC Configuration IL=120mA RON -19 35
DC Configuration IL=200mA 7 10
Off-State Leakage Current VL=350VPILEAK -- 1µA
Switching Speeds
Turn-On IF=5mA, VL=10V ton --3
ms
Turn-Off toff -3
Output Capacitance VL=50V, f=1MHz COUT -25 - pF
Input Characteristics
Input Control Current IL=120mA IF- 1.1 2 mA
Input Dropout Current - IF0.4 1.0 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics
Input to Output Capacitance - CI/O -3 -pF
1 Measurement taken within 1 second of on-time.
Electrical Characteristics @ 25°C
LCA110L
www.clare.com 3
R03
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
Typical LED Forward Voltage Drop
(N=50, IF=5mA, TA=25ºC)
35
30
25
20
15
10
5
0
1.17 1.19 1.21 1.23 1.25
LED Forward Voltage Drop (V)
Device Count (N)
Typical Turn-On Time
(N=50, IF=5mA, IL=120mADC, TA=25ºC)
0.15 0.35 0.55 0.750.25 0.45 0.65
Turn-On (ms)
Device Count (N)
25
20
15
10
5
0
0.025 0.125
0.225
0.1750.075
Turn-Off (ms)
Device Count (N)
25
20
15
10
5
0
Typical Turn-Off Time
(N=50, IF=5mA, IL=120mADC, TA=25ºC)
Typical IF for Switch Operation
(N=50, IL=120mADC, TA=25ºC)
0.75 1.35 1.950.45 1.05 1.65 2.25
LED Current (mA)
Device Count (N)
25
20
15
10
5
0
Typical IF for Switch Dropout
(N=50, IL=120mADC, TA=25ºC)
25
20
15
10
5
0
0.75 1.35 1.950.45 1.05 1.65 2.25
LED Current (mA)
Device Count (N)
Typical On-Resistance Distribution
(N=50, IF=2mA, IL=120mADC, TA=25ºC)
35
30
25
20
15
10
5
0
17.0 17.8 18.6 19.417.4 18.2 19.0
On-Resistance (:)
Device Count (N)
Typical Blocking Voltage Distribution
(N=50, TA=25ºC)
35
30
25
20
15
10
5
0
376.3 389.3 402.3 415.3382.8 395.8 408.8
Blocking Voltage (VP)
Device Count (N)
Typical LED Forward Voltage Drop
vs. Temperature
Temperature (ºC)
LED Forward Voltage Drop (V)
1.8
1.6
1.4
1.2
1.0
0.8
-40 -20 0 20 40 60 80 120100
I
F
=50mA
I
F
=30mA
I
F
=20mA
I
F
=10mA
I
F
=5mA
Typical Turn-On
vs. LED Forward Current
(IL=120mADC)
LED Forward Current (mA)
Turn-On (ms)
05 1015202530354045
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
50
Typical Turn-Off
vs. LED Forward Current
(IL=120mADC)
LED Forward Current (mA)
Turn-Off (ms)
05 1015202530354045
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0
50
www.clare.com
4R03
LCA110L
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
Typical Turn-On vs. Temperature
(IL=120mADC)
Temperature (ºC)
IF=10mA
IF=20mA
Turn-On (ms)
-40
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
-20 0 20 40 60 80 100
IF=5mA
IF=2mA
Typical Turn-Off vs. Temperature
(IF=120mADC)
Temperature (ºC)
Turn-Off (ms)
-40
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
-20 0 20 40 60 80 100
IF=5mA
IF=2mA
Typical Load Current vs. Temperature
Temperature (ºC)
Load Current (mA)
180
160
140
120
100
80
60
40
20
0
-40 -20 0 20 40 60 80 120100
IF=10mA
IF=2mA
IF=5mA
Typical IF for Switch Operation
vs. Temperature
(IL=120mADC)
Temperature (ºC)
LED Current (mA)
-40
3.0
2.5
2.0
1.5
1.0
0.5
0
-20 0 20 40 60 80
Typical IF for Switch Dropout
vs. Temperature
(IL=120mADC)
Temperature (ºC)
LED Current (mA)
-40
3.0
2.5
2.0
1.5
1.0
0.5
0
-20 0 20 40 60 80 100
Typical On-Resistance vs. Temperature
(IF=2mA, IL=120mADC)
Temperature (ºC)
On-Resistance (:)
-40
60
50
40
30
20
10
0
-20 0 20 40 60 80 100
Typical Load Current vs. Load Voltage
(IF=2mA, TA=25ºC)
Load Voltage (V)
Load Current (mA)
150
100
50
0
-50
-100
-150
-3 -2 -1 0 1 2 3
Typical Blocking Voltage
vs. Temperature
Temperature (ºC)
Blocking Voltage (VP)
-40
420
410
400
390
380
370
360
-20 0 20 40 60 80 100
Typical Leakage vs. Temperature
Measured across Pins 4 & 6
Temperature (ºC)
Leakage (nA)
-40
16
14
12
10
8
6
4
2
0
-20 0 20 40 60 80 100
Typical Current Limiting
vs. Temperature
(IF=2mA)
Temperature (ºC)
Current (mA)
-40
250
200
150
100
50
0
-20 0 20 40 60 80 100
350
300
LCA110L
www.clare.com 5
R03
Manufacturing Information
Moisture Sensitivity
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. Clare classified all
of its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry
standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of our products to the
maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled according
to the limitations and information in that standard as well as to any limitations set forth in the information or standards
referenced below.
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced
product performance, reduction of operable life, and/or reduction of overall reliability.
This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according to
the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.
Device Moisture Sensitivity Level (MSL) Rating
LCA110L / LCA110LS MSL 1
ESD Sensitivity
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.
Reflow Profile
This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020
must be observed.
Device Maximum Temperature x Time
LCA110L / LCA110LS 250ºC for 30 seconds
Board Wash
Clare recommends the use of no-clean flux formulations. However, board washing to remove flux residue is acceptable.
Since Clare employs the use of silicone coating as an optical waveguide in many of its optically isolated products,
the use of a short drying bake may be necessary if a wash is used after solder reflow processes. Chlorine-based or
Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy should not be
used.
RoHS
2002/95/EC e3
Pb
www.clare.com
6R03
LCA110L
MECHANICAL DIMENSIONS
LCA110L
LCA110LS
Dimensions
mm
(inches)
PCB Land Pattern
0.254 ± 0.0127
(0.010 ± 0.0005)
7.620 ± 0.254
(0.300 ± 0.010)
0.635 ± 0.127
(0.025 ± 0.005)
3.302 ± 0.051
(0.130 ± 0.002)
4.445 ± 0.254
(0.175 ± 0.010)
2.54
(0.10)
8.90
(0.3503)
1.65
(0.0649)
0.65
(0.0255)
8.382 ± 0.381
(0.330 ± 0.015) 2.54 ± 0.127
(0.100 ± 0.005)
9.524 ± 0.508
(0.375 ± 0.020) 6.350 ± 0.127
(0.250 ± 0.005)
0.457 ± 0.076
(0.018 ± 0.003)
1.651 ± 0.254
(0.065 ± 0.010)
1.651 ± 0.254
(0.065 ± 0.010)
Dimensions
mm
(inches)
PCB Hole Pattern
6.350 ± 0.127
(0.250 ± 0.005)
2.540 ± 0.127
(0.100 ± 0.005)
7.620 ± 0.127
(0.300 ± 0.005)
5.080 ± 0.127
(0.200 ± 0.005)
6 - 0.800 DIA.
(6 - 0.031 DIA.)
0.254 ± 0.0127
(0.010 ± 0.0005)
9.144 ± 0.508
(0.360 ± 0.020)
7.239 TYP
(0.285 TYP)
7.620 ± 0.254
(0.300 ± 0.010)
3.302 ± 0.051
(0.130 ± 0.002) 4.064 TYP
(0.160 TYP)
0.457 ± 0.076
(0.018 ± 0.003)
8.382 ± 0.381
(0.330 ± 0.015) 2.54 ± 0.127
(0.100 ± 0.005)
6.350 ± 0.127
(0.250 ± 0.005)
1.651 ± 0.254
(0.065 ± 0.010)
Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and
product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of Sale,
Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for
a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications
intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare,
Inc. reserves the right to discontinue or make changes to its products at any time without notice.
Specification: DS-LCA110L-R03
©Copyright 2011, Clare, Inc.
OptoMOS® is a registered trademark of Clare, Inc.
All rights reserved. Printed in USA.
5/25/2011
For additional information please visit our website at: www.clare.com
7
LCA110L
MECHANICAL DIMENSIONS
LCA110LS Tape & Reel
NOTES:
1. All dimensions carry tolerances of EIA Standard 481-2
2. The tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2
Dimensions
mm
(inches)
Embossment
Embossed
Carrier
330.2 Dia
(13.00 Dia)
Top Cover
Tape Thickness
0.102 Max
(0.004 Max)
W=16.00
(0.63)
B0 = 10.10
(0.398)
A0 = 10.10
(0.398)
P = 12.00
(0.472)
K1 = 3.80
(0.15)
K0 = 4.90
(0.19)
User Direction of Feed