PDU1064H data 3 delay devices, inc. 6-BIT, ECL-INTERFACED PROGRAMMABLE DELAY LINE (SERIES PDU1064H) FEATURES * * * * * PACKAGES Digitally programmable in 64 delay steps Monotonic delay-versus-address variation Precise and stable delays Input & outputs fully 10KH-ECL interfaced & buffered Fits 48-pin DIP socket GND ENB 1 48 GND 2 47 OUT A0 7 42 VEE 8 41 A1 A2 GND 9 40 GND PIN DESCRIPTIONS IN OUT A0-A5 ENB VEE GND Signal Input Signal Output Address Bits Output Enable -5 Volts Ground A3 15 34 VEE 16 33 A4 A5 GND 17 32 GND IN 19 VEE 24 N/C N/C OUT GND ENB N/C N/C N/C GND ENB N/C N/C N/C N/C N/C N/C N/C GND ENB IN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 N/C N/C A2 A1 VEE A0 N/C A5 A4 VEE A3 N/C N/C N/C N/C N/C N/C N/C VEE N/C PDU1064H-xxC5 SMD PDU1064H-xxMC5 Mil SMD PDU1064H-xx DIP PDU1064H-xxM Mil DIP FUNCTIONAL DESCRIPTION The PDU1064H-series device is a 6-bit digitally programmable delay line. The delay, TDA, from the input pin (IN) to the output pin (OUT) depends on the address code (A5-A0) according to the following formula: TDA = TD0 + TINC * A where A is the address code, TINC is the incremental delay of the device, and TD0 is the inherent delay of the device. The incremental delay is specified by the dash number of the device and can range from 0.5ns through 10ns, inclusively. The enable pin (ENB) is held LOW during normal operation. When this signal is brought HIGH, OUT is forced into a LOW state. The address is not latched and must remain asserted during normal operation. SERIES SPECIFICATIONS DASH NUMBER SPECIFICATIONS * Part Number PDU1064H-.5 PDU1064H-1 PDU1064H-2 PDU1064H-3 PDU1064H-4 PDU1064H-5 PDU1064H-6 PDU1064H-8 PDU1064H-10 * * * * * * Total programmed delay tolerance: 5% or 2ns, whichever is greater Inherent delay (TD0): 12ns typical Setup time and propagation delay: Address to input setup (TAIS): 3.6ns Disable to output delay (TDISO): 1.7ns typical Operating temperature: 0 to 70 C Temperature coefficient: 100PPM/C (excludes TD0) Supply voltage VEE: -5VDC 5% Power Dissipation: 925mw typical (no load) Minimum pulse width: 20% of total delay Incremental Delay Per Step (ns) 0.5 0.3 1.0 0.5 2.0 0.5 3.0 1.0 4.0 1.0 5.0 1.0 6.0 1.0 8.0 1.0 10.0 1.5 Total Delay (ns) 31.5 2.0 63 3.1 126 6.3 189 9.4 252 12.6 315 15.7 378 18.9 504 25.2 630 31.5 NOTE: Any dash number between .5 and 10 not shown is also available. 1997 Data Delay Devices Doc #97046 12/17/97 DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 1 PDU1064H APPLICATION NOTES possibility of spurious signals persists until the required TDISH has elapsed. ADDRESS UPDATE The PDU1064H is a memory device. As such, special precautions must be taken when changing the delay address in order to prevent spurious output signals. The timing restrictions are shown in Figure 1. INPUT RESTRICTIONS There are three types of restrictions on input pulse width and period listed in the AC Characteristics table. The recommended conditions are those for which the delay tolerance specifications and monotonicity are guaranteed. The suggested conditions are those for which signals will propagate through the unit without significant distortion. The absolute conditions are those for which the unit will produce some type of output for a given input. After the last signal edge to be delayed has appeared on the OUT pin, a minimum time, TOAX, is required before the address lines can change. This time is given by the following relation: TOAX = max { (Ai - A i-1) * TINC , 0 } where A i-1 and Ai are the old and new address codes, respectively. Violation of this constraint may, depending on the history of the input signal, cause spurious signals to appear on the OUT pin. The possibility of spurious signals persists until the required TOAX has elapsed. When operating the unit between the recommended and absolute conditions, the delays may deviate from their values at low frequency. However, these deviations will remain constant from pulse to pulse if the input pulse width and period remain fixed. In other words, the delay of the unit exhibits frequency and pulse width dependence when operated beyond the recommended conditions. Please consult the technical staff at Data Delay Devices if your application has specific high-frequency requirements. A similar situation occurs when using the ENB signal to disable the output while IN is active. In this case, the unit must be held in the disabled state until the device is able to "clear" itself. This is achieved by holding the ENB signal high and the IN signal low for a time given by: Please note that the increment tolerances listed represent a design goal. Although most delay increments will fall within tolerance, they are not guaranteed throughout the address range of the unit. Monotonicity is, however, guaranteed over all addresses. TDISH = Ai * TINC Violation of this constraint may, depending on the history of the input signal, cause spurious signals to appear on the OUT pin. The A5-A0 A i-1 Ai TOAX TAENS TAIS ENB TENIS PWIN TDISH IN TDA PWOUT TDISO OUT Figure 1: Timing Diagram Doc #97046 12/17/97 DATA DELAY DEVICES, INC. Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com 2 PDU1064H DEVICE SPECIFICATIONS TABLE 1: AC CHARACTERISTICS PARAMETER Total Programmable Delay Inherent Delay Disable to Output Low Delay Address to Enable Setup Time Address to Input Setup Time Enable to Input Setup Time Output to Address Change Disable Hold Time Absolute Input Period Suggested Recommended Absolute Input Pulse Width Suggested Recommended SYMBOL TDT TD0 TDISO TAENS TAIS TENIS TOAX TDISH PERIN PERIN PERIN PWIN PWIN PWIN MIN TYP 63 12.0 1.7 UNITS TINC ns ns ns ns ns 1.0 3.6 3.6 See Text See Text 16 40 200 8 20 100 % of TDT % of TDT % of TDT % of TDT % of TDT % of TDT TABLE 2: ABSOLUTE MAXIMUM RATINGS PARAMETER DC Supply Voltage Input Pin Voltage Storage Temperature Lead Temperature SYMBOL VEE VIN TSTRG TLEAD MIN -7.0 VEE - 0.3 -55 MAX 0.3 0.3 150 300 UNITS V V C C NOTES 10 sec TABLE 3: DC ELECTRICAL CHARACTERISTICS (0C to 75C) PARAMETER High Level Output Voltage Low Level Output Voltage High Level Input Voltage Low Level Input Voltage High Level Input Current Low Level Input Current Doc #97046 12/17/97 SYMBOL VOH VOL VIH VIL IIH IIL MIN -1.020 -1.950 TYP MAX -0.735 -1.600 -1.070 -1.480 475 0.5 UNITS V V V V A A DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 NOTES VIH = MAX,50 to -2V VIL = MIN, 50 to -2V VIH = MAX VIL = MIN 3 PDU1064H PACKAGE DIMENSIONS 48 47 42 41 40 34 33 32 .400 TYP. 1 2 7 8 9 15 16 17 19 24 2.450 TYP. .020 .320 TYP. MAX. .150 .030 .018 TYP. .100 .600 .700 .800 .012 TYP. .300 TYP. 1.400 1.500 1.600 1.800 2.300 .075 PDU1064H-xx (Commercial DIP) PDU1064H-xxM (Military DIP) .020 TYP. .040 TYP. .010.002 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 .882 .005 .710 .590 .005 MAX. 1 2 3 4 5 6 7 8 9 .007 .005 10 11 12 13 14 15 16 17 18 19 20 .090 .100 1.100 2.080.020 .280 MAX. .050 .010 PDU1064H-xxC5 (Commercial SMD) PDU1064H-xxMC5 (Military SMD) Doc #97046 12/17/97 DATA DELAY DEVICES, INC. Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com 4 PDU1064H DELAY LINE AUTOMATED TESTING TEST CONDITIONS INPUT: Ambient Temperature: 25oC 3oC Supply Voltage (Vcc): -5.0V 0.1V Input Pulse: Standard 10KH ECL levels Source Impedance: 50 Max. Rise/Fall Time: 2.0 ns Max. (measured between 20% and 80%) Pulse Width: PWIN = 1.5 x Total Delay Period: PERIN = 10 x Total Delay OUTPUT: Load: Cload: Threshold: 50 to -2V 5pf 10% (VOH + VOL) / 2 (Rising & Falling) NOTE: The above conditions are for test only and do not in any way restrict the operation of the device. REF PULSE GENERATOR OUT IN TRIG DEVICE UNDER TEST (DUT) OUT IN OSCILLOSCOPE TRIG ADDRESS SELECT Test Setup PERIN PWIN TRISE INPUT SIGNAL TFALL VIH 80% 50% 20% 80% 50% 20% TRISE OUTPUT SIGNAL VIL TFALL VOH 50% 50% VOL Timing Diagram For Testing Doc #97046 12/17/97 DATA DELAY DEVICES, INC. 3 Mt. Prospect Ave. Clifton, NJ 07013 5