Product Data Sheet
4312/17MT
The engineer's choice
Product Data Sheet 4312/17MT
08/12/2014 page 2 of 11
4312/17MT
INDEX
1 General ...................................................................................................................................................................... 3
2 Mechanics ................................................................................................................................................................. 3
2.1 General .............................................................................................................................................................. 3
2.2 Connections....................................................................................................................................................... 3
3 Operating Data ......................................................................................................................................................... 4
3.1 Operating Data - Electrical Interface - Input ...................................................................................................... 4
3.2 Electrical Operating Data .................................................................................................................................. 5
3.3 Operating Data - Electrical Interface -Output .................................................................................................... 6
3.4 Electrical Features ............................................................................................................................................. 7
3.5 Aerodynamic...................................................................................................................................................... 8
3.6 Sound Data........................................................................................................................................................ 9
4 Environment ............................................................................................................................................................. 9
4.1 General .............................................................................................................................................................. 9
4.2 Climatic requirements*) ..................................................................................................................................... 9
5 Safety ...................................................................................................................................................................... 10
5.1 Electrical Safety ............................................................................................................................................... 10
5.2 Approval Tests ................................................................................................................................................ 10
6 Reliability ................................................................................................................................................................ 10
6.1 General ............................................................................................................................................................ 10
Product Data Sheet 4312/17MT
08/12/2014 page 3 of 11
1 General
Fan type Fan
Rotational direction looking at rotor clockwise
Airflow direction Air outlet over struts
Bearing system Ball bearing
Mounting position any
2 Mechanics
2.1 General
Width 119,0 mm
Height 119,0 mm
Depth 32,0 mm
Weight 0,200 kg
Housing material Plastic
Impeller material Plastic
Max. torque when mounted across both mounting
flanges wire outlet corner: 20 Ncm
remaining corners: 20 Ncm
Screw size ISO 4762 - M4 degreased, without an additional
brace and without washer
2.2 Connections
Electrical connection Wires
Length of lead wire L = 310 mm
Tolerance +- 10,0 mm
Wire gauge (AWG) 24
Insulation diameter 1,55 mm
Contact see drawing
Colour Operation
Wire 1 red + UB
Wire 2 blue - GND
Wire 3 violet NTC
Wire 4 white Alarm
The auxilliaries shown on the schematic diagram (which are required for the intended use) are not part of our delivery.
Product Data Sheet 4312/17MT
08/12/2014 page 4 of 11
3 Operating Data
3.1 Operating Data - Electrical Interface - Input
Control input cExternal Temperature Sensor
Features
Characteristics
Schematics
Product Data Sheet 4312/17MT
08/12/2014 page 5 of 11
3.2 Electrical Operating Data
Measurement
conditions: Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0: corresp. to free air flow (see section 3.5)
I: corresp. to arithm. mean current value
Name
Condition
TU 0001 TU: >= 50 °C
NTC 0001 NTC <= 34 kOhm
Features
Condition
Symbol
Voltage range p = 0 U 8,0 V 15,0 V
Nominal voltage p = 0 U
N
12,0 V
Power consumption p = 0
TU / NTC
0001
P
1,3 W 3,3 W 5,6 W
Tolerance +- 25,0 % +- 25,0 % +- 25,0 %
Current consumption p = 0
TU / NTC
0001
I
160 mA 275 mA 370 mA
Tolerance +- 25,0 % +- 25,0 % +- 25,0 %
Speed p = 0
TU / NTC
0001
n
1.500 1/min 2.300 1/min 2.800 1/min
Tolerance +- 15,0 % +- 15,0 % +- 15,0 %
Starting current
consumption 1.200 mA
Name
Condition
TU 0002 TU: <= 25 °C
NTC 0002 NTC >= 100 kOhm
Features
Condition
Symbol
Voltage range p = 0 U 8,0 V 15,0 V
Nominal voltage p = 0 U
N
12,0 V
Power consumption p = 0
TU / NTC
0002
P
0,65 W 1,1 W 1,4 W
Tolerance +- 25,0 % +- 25,0 % +- 25,0 %
Current consumption p = 0
TU / NTC
0002
I
80 mA 90 mA 95 mA
Tolerance +- 25,0 % +- 25,0 % +- 25,0 %
Speed p = 0
TU / NTC
0002
n
1.100 1/min 1.100 1/min 1.100 1/min
Tolerance +- 15,0 % +- 15,0 % +- 15,0 %
Product Data Sheet 4312/17MT
08/12/2014 page 6 of 11
3.3 Operating Data - Electrical Interface -Output
Tacho type None
Alarm type /17 (high = ok, Open collector)
Features
Note
Alarm operating voltage (UBA) <= 60 V
Alarm signal Low *) I sink: 2 mA <= 0,4 V
Alarm signal High *) I source: 0 mA 60 V
Maximum sink current 20 mA
External resistor External resistor Ra from
UBA to UA required. All
voltage measured to GND.
Alarm start-up delay time (t2) <= 15 s
Alarm trip speed limit (nG) 850 1/min
Tolerance +- 100 1/min
Alarm at sense failure No
Alarm latch No
Alarm isolated from motor No
Product Data Sheet 4312/17MT
08/12/2014 page 7 of 11
3.4 Electrical Features
Electronic function Speed-Controlled
Reversed polarity protection Rectifying diode
Max. residual current at Un IF <= 10 mA
Locked rotor protection Auto restart
Locked rotor current at Un approx. 1.200 mA
Clock signal t3/t4 at locked rotor Typical: 1,0 s / 10 s
Product Data Sheet 4312/17MT
08/12/2014 page 8 of 11
3.5 Aerodynamic
Measurement
conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m.
The information is only valid under the specified test conditions and may be changed by the
installation conditions. If there are deviations from the standard test conditions, the
characteristic values must be checked under the installed conditions.
a.) Operation condition:
2.300 1/min at free air flow TU >= 50 °C
NTC <= 34 kOhm
Max. free-air flow (p = 0 /
= max.) 138,0 m3/h
Max. static pressure (p = max. /
=0) 54 Pa
Product Data Sheet 4312/17MT
08/12/2014 page 9 of 11
3.6 Sound Data
Measurement
conditions: Sound pressure level: 1 Meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see section 3.5
a.) Operation condition:
2.300 1/min at free air flow TU >= 50 °C
NTC <= 34 kOhm
Optimal operating point 118,0 m3/h @ 9 Pa
Sound power level at the optimal operating
point 5,3 bel(A)
Sound pressure level at free air flow,
measured in rubber bands 39,0 dB(A)
4 Environment
4.1 General
Min. permitted ambient temperature TU min. -20 °C
Max. permitted ambient temperature TU max. 65 °C
Min. permitted storage temperature TL min. -40 °C
Max. permitted storage temperature TL max. 80 °C
4.2 Climatic requirements*)
Humidity requirements humid heat, constant; according to DIN EN 60068-2-
78, 14 days
Water exposure None
Dust requirements None
Salt fog requirements None
*) Permittet application area:
The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly
exposure to water must be avoided.
Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.Please
require severity levels and specification parameters from the responsible development departments
Product Data Sheet 4312/17MT
08/12/2014 page 10 of 11
5 Safety
5.1 Electrical Safety
Dielectric strength
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE
0700)
A.) Type test
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C.
No arcing or breakdown is allowed!
All connections together to ground.
500 VAC / 1 Min.
B.) Routine test
Measuring conditions: At indoor climate.
No arcing or breakdown is allowed!
All connections together to ground.
500 VAC / 1 Sec.
Isolation resistance
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C measured with U=500 VDC for 1 min.
RI > 10 MOhm
clearance / creepage distance 1,0 mm / 1,2 mm
Protection class III
5.2 Approval Tests
CE Yes
UL Yes / UL507, Electric Fans
VDE Yes / Approval acc. to EN 60950 (VDE 0805) - Information
technology equipment
CSA Yes / C22.2 No. 113 Fans and Ventilators
CCC No
6 Reliability
6.1 General
Life expectancy L10 at TU = 40 °C 70.000 h
Life expectancy L10 at TU max. 40.000 h
Life expectancy L10 Delta (40 °C) 142.500 h