1
2018.7
36.4
Receptacle Plug
Ø13
8.9 mm max. (3 pos.)
Miniature Waterproof Shielded Connectors
LF Series
Fig. 1
Features
1. Ease of shielded termination and
connector assembly
All components are self-aligning and do not require
complex assembly tooling. The shield of the cable is
connected with the metal housing of the connector
using simple shielding clamp, supplied with the
connector. (Fig. 2)
2. Water and dust protected
The LF series is a rugged, waterproof connector
series that is IP67 and IP68 rated in the mated
condition.
IP67 : Left in water at a depth of 1 m for 30 minutes
IP68 : Left in water at a depth of 2 m for 14 days
3. Simplified assembly procedure
No use of screws makes wiring and mounting easier.
4. Bayonet lock
Short turn bayonet lock assures secure vibration
resistant mating of the connectors. (Fig. 3)
5. Acquired safety standard
4 pos. is 10A and meets safety standards (TÜV)
Also 3- and 4-pos. have acquired the UL standard.
6. High current rating capacity
Mated dimensions (Example : LF07)
No. of contacts
3
4
6, 12 and 20
11
Current rating
5A max.
10A max.
2A max.
10A max.
2A max.
Built-in shield
connection spring Cable shielding connection clamp
Cable
Shielding Connection - Plug
Fig. 2
M
at
i
n
g
:
I
nsert t
h
e p
l
u
g
, an
d
t
h
en turn t
h
e
l
oc
ki
n
g
co
ll
ar c
l
oc
k
w
i
se
,
as
i
n
di
cate
d
b
y t
h
e coup
li
n
g
di
rect
i
on mar
ki
n
g
.
Mating:
Insert the plug, and then turn the locking collar clockwise,
as indicated by the coupling direction marking.
Pl
u
g
Plug
L
oc
ki
n
g c
o
ll
ar
Locking collar
R
ec
ept
ac
l
e
Receptacle
Un-mating:
Turn the locking collar counter-clockwise
then pull off the plug.
ou
pli
ng
direction marki
ng
Coupling direction marking
C
ouplin
g
direction markin
g
Coupling direction marking
2
1
1
2
Short turn bayonet lock
Fig. 3
In cases where the application will demand a high level of reliability, such as automotive,
please contact a company representative for further information.
Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved.
2
LF SeriesMiniature Waterproof Shielded Connectors
Series name : LF
Shell size 07
10
13
Waterproof W : Waterproof type
Lock Mechanism B : Bayonet lock
Connector type P : Plug
R : Receptacle
J : Jack
(* : Form change zoning symbols in an identical class)
Product Specifi cations
Ratings
Voltage rating
125V AC, 175V DC (3 pos.)
125V AC, 125V DC (4 pos.)
30V AC, 42V DC (6 pos. , 12pos. , 20pos.)
125V AC, 125V DC (11 pos. A to D)
30V AC, 42V DC (11 pos. 1 to 7)
Current rating
5A max. (3 pos.)
10A max. (4 pos.)
2A max. (6 pos. , 12pos. , 20pos.)
10A(11 pos. A to D), 2A(11 pos. 1 to 7)
Operating temperature range –25ç to +85ç
Storage temperature range –10ç to +60ç
Item Specifi cations Conditions
1.Contact resistance
15mø max. (3, 6, 12, 20 pos.)
5mø max. (4 pos.)
5mø max. (A to D), 15mø max. (1 to 7)(11 pos.) 1A DC
2.Insulation resistance
1000Mø min. 500V DC (3, 4 pos.)
100V DC (6, 12, 20 pos.)
500V DC (A to D), 100V DC (1 to 7)(11pos.)
3.Withstanding voltage
No fl ashover or insulation breakdown.
1250V AC/1 minute (3, 4 pos.)
300V AC/1 minute (6, 12, 20 pos.)
1250V AC(A to D),300V AC(1 to 7) / 1 minute(11pos.)
4.Vibration
No electrical discontinuity for 10µs max. 10 55 10Hz /cycle, single amplitude of
0.75mm 5 minutes / cycle, three directions,
10 cycles for each direction.
5.Shock
No electrical discontinuity for 10µs max
Acceleration of 490m/s2, duration of 11ms, three
directions, three times for each direction.
6.Durability6.
(Mating/un-mating)
30mø max. (3, 6, 12, 20 pos.)
10mø max. (4 pos.)
10mø max.(A to D), 30mø max.(1 to 7)(11pos.) 1000 cycles
7.Temperature cycle
Insulation resistance : 100Mø min.
Temperature : -55ç Room temperature +85ç
Room temperature
Time : 30 2 to 3 30 2 to 3 (minutes) 5 cycles
8.Humidity Insulation resistance : 10Mø min. (at high humidity condition)
Insulation resistance : 100Mø min. (at dry condition)
96 hours at temperature of 40ç and humidity
of 90% to 95%.
9.
Water / dust protection
When mated with corresponding connector.
Complete dust protection. No water penetration
when submerged for 48 hours at the depth of 1.8 meter.
Materials / Finish
Components Material Finish / Color Remarks
Body / back shell Zinc alloy Nickel plated ––––––––––
Insulator PPS Black UL94V-0
Contacts Copper alloy Selective Gold plated ––––––––––
Packing Chloroprene rubber Black ––––––––––
Tightening collar PPS Brown UL94V-0
Product Number Structure
Refer to the chart below when determining the product specifications from the product number.
Please select from the product numbers listed in this catalog when placing orders.
LF 07 -WB P
*-6S(**)
❶❷ ❹❺
No. of contacts : 3, 4, 6, 11, 12, 20
Contact type P : Male contact
S : Female contact
Other specifications :
A two-digit character is added to
indicate other specifications as needed.
2 7
3
4
5
1 6
8
Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved.
3
LF SeriesMiniature Waterproof Shielded Connectors
Plugs
ØA
B
ØC (Cable dia.)
ØA
B
ØC(Cable dia.)
Lock ease type
Unit : mm
(Representative example.)
(Representative example.)
Unit : mm
Part No. HRS No. No. of contacts ØA B ØCØC Weight
LF07WBPD-6S(31)
LF10WBPD-4S(31)
LF10WBPD-4P(31)
LF10WBPD-12S(31)
LF10WBPD-12P(31)
136-0020-6 31
136-0014-3 31
136-0017-1 31
136-0015-6 31
136-0018-4 31
4
12
16.8 41.8 7.3 19g
Part No. HRS No. No. of contacts ØA B ØC Weight
LF07WBP-3S(31)
LF07WBP-3P(31)
LF07WBP-6S(31)
LF07WBP-6P(31)
LF10WBP-4S(31)
LF10WBP-4P(31)
LF10WBP-12S(31)
LF10WBP-12P(31)
LF13WBP-20S
LF13WBP-20P
LF13WBP-11S
LF13WBP-11P
136-0003-7 31
136-0004-0 31
136-0001-1 31
136-0002-4 31
136-0005-2 31
136-0006-5 31
136-0007-8 31
136-0008-0 31
136-0009-3
136-0010-2
136-0011-5
136-0012-8
3
6
4
12
20
11
12.3
14.8
17.9
35.8
41.8
51.9
5
7.3
8.7
11g
17g
16g
29g
6 14.3 35.8 5 12g
Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved.
4
LF SeriesMiniature Waterproof Shielded Connectors
E
ØA
ØB
D
C
F(HEX)
Receptacles
Front panel mount typeSolder Type
Unit : mm
Part No. HRS No. No. of contacts ØA ØB ØCC D E Weight
LF07WBR-3P
LF07WBR-3S
LF07WBR-6P
LF07WBR-6S
LF10WBR-4P
LF10WBR-4S
LF10WBR-12P
LF10WBR-12S
LF13WBR-20P
LF13WBR-20S
LF13WBR-11P
LF13WBR-11S
136-1003-2
136-1004-5
136-1001-7
136-1002-0
136-1005-8
136-1006-0
136-1007-3
136-1008-6
136-1009-9
136-1010-8
136-1011-0
136-1012-3
3
6
4
12
20
11
10.3
12.8
15.9
13
15.3
18.3 7.75
16.55
15.05
15.25
19.05
17.25
17.25
19.05
7.65
7.75
1M9∞0.75
M11∞0.75
M14∞0.75
4g
6g
5g
6g
9g
10g
9g
10g
F
11
13
17
(Representative example.)
(Representative example.)
Front panel mount typeThrough hole Type
ØA
ØB
D
C
E
F(HEX)
Unit : mm
Part No. HRS No. No. of contacts ØA ØB C DE F Weight
LF13WBR-20SD 136-1017-7 20 15.9 18.3 17.5 7.75 M14∞0.75 17 9g
Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved.
5
LF SeriesMiniature Waterproof Shielded Connectors
Rear panel mount type Through hole Type
ØA
C
E
ØB
Unit : mm
ØA
C
E
D(HEX)
ØB
Receptacles
Rear panel mount typeSolder Type
Jacks
ØA
ØB
C
ØD (Cable dia.)
Unit : mm
(Representative example.)
(Representative example.)
(Representative example.)
Part No. HRS No. No. of contacts ØA ØB C D E Weight
LF10WBRB-12PD 136-1015-1 12 12.8 18.3 17.5 17 M14∞0.75 9g
LF10WBRB-12SD 136-1016-4
Unit : mm
Part No. HRS No. No. of contacts ØA ØB C D E Weight
LF10WBRB-4P 136-1118-4 4
12.8 18.3
19.05
17 M14∞0.75 10g
LF10WBRB-12P 136-1013-6 12 17.25
LF10WBRB-12S 136-1014-9
LF13WBRB-20S 136-1018-0 20 15.9 21.5 19.25 20 M17∞0.75 16g
LF13WBRB-11S 136-1019-2 11
Part No. HRS No. No. of contacts ØA ØB C ØD Weight
LF07WBJ-3P 136-2003-8 3
10.3 11.5 36.3 5 11g
LF07WBJ-3S 136-2004-0
LF07WBJ-6P 136-2001-2 6
LF07WBJ-6S 136-2002-5
LF10WBJ-4P 136-2005-3 4
12.8 13.8 42.4 7.3 16g
LF10WBJ-4S 136-2006-6
LF10WBJ-12P 136-2007-9 12
LF10WBJ-12S 136-2008-1
LF13WBJ-20P 136-2009-4 20
15.9 16.9 52.4 8.7
29g
LF13WBJ-20S 136-2010-3 30g
LF13WBJ-11P 136-2011-6 11 29g
LF13WBJ-11S 136-2012-9 30g
D(HEX)
Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved.
6
LF SeriesMiniature Waterproof Shielded Connectors
CAP
For Receptacles
B
ØA
Unit : mm
(Representative example.)
Part No. HRS No. Applicable connector ØA B Weight
LF07WBR-C 136-3008-7
LF07WBR-6P
12.3
8.8
4g
LF07WBR-6S
LF07WBR-3P
LF07WBR-3S
LF10WBR-C 136-3001-8
LF10WBR-4P
14.8 5g
LF10WBR-4S
LF10WBR-12P
LF10WBR-12S
LF10WBRB-4P
LF10WBRB-12P
LF10WBRB-12S
LF10WBRB-12PD
LF10WBRB-12SD
LF13WBR-C 136-3003-3
LF13WBR-20P
17.9 7g
LF13WBR-20S
LF13WBR-11P
LF13WBR-11S
LF13WBR-20SD
LF13WBRB-20S
LF13WBRB-11S
Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved.
7
LF SeriesMiniature Waterproof Shielded Connectors
BContact position arrangement and specifications
Note 1 : The contact configuration as viewed from the female contact connector mating side.
Note 2 : The symbol indicates polarizing key position.
Note 3 : Withstanding voltages are test voltage values.
A
+0.05
0
Alignment guide
B+0.05
0
BPanel Cutout Unit : mm
13
2
1
2
34
5
61
2
3
4
1
2
3
4
5
6
7
8
9
10
1112 A
B
2
5 6
13
7
4
D
C32
1
876 9 10
4 5
1716
20
131211 14 15
18 19
BSolder termination fixture
Note : It is applicable regard less of given
alphabets or Numbers shown at *.
HRS No.Part No. Applicable connectors
150-0232-0
150-0233-3
150-0235-9
150-0236-1
150-0237-4
150-0238-7
LF07BP-T01
LF07BJ-T01
LF10BP-T01
LF10BJ-T01
LF13BP-T01
LF13BJ-T01
LF07WBP-**
LF07WBJ-**
LF10WBP-**
LF10WBJ-**
LF13WBP-**
LF13WBJ-**
(Representative example.) (Representative example.)
BApplicable tools
Part No.Description HRS No.
LF series Applicable cable dia.
HR10A-TC-02
LF-TC-01
Manual cable
clamp crimp
Note : Applicable cable dia. is only 5mm for LF series.
150-0041-2
150-0234-6
5 (Note)
7.3 · 8.7
Unit : mm
(Representative example.)
Shell size LF07 LF10 LF13
Contact arrangement
No. of contacts 3 6 4 12 11 20
Withstanding voltage 1250V AC 300V AC 1250V AC 300V AC 47 AC300V
AC1250V
AC300V
Current rating 5A 2A 10A 2A 47 2A
10A 2A
Insulation resistance 1000Mø
Contact resistance 15mø 5mø 15mø 47 15mø
5mø 15mø
Solder pot inner diameter
1.15mm 0.8mm 1.7mm 0.8mm 47 0.8mm
Ø1.7 Ø0.8
Shell size AB Weight
LF07WBR-** Ø9.05 8.1
0.7 to 2
LF10WBR-** Ø11.05 10.2
LF13WBR-** Ø14.05 13.1
LF10WBRB-**
LF13WBRB-** Ø17.05 16.1 0.7 to 4.8
Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved.
8
LF SeriesMiniature Waterproof Shielded Connectors
󱽧Termination and Assembly Instructions
22Thread the tightening collar, strain relief collar,
seal bushing and the backshell over the cable
as illustrated.
No. Illustration Operation
Solder termination fixture
1Plug 1
Plug disassembly
Insertion direction
Body / insulator assembly
Locking collar
Backshell
2
1
2
1
2
1
2
Solder termination fixture
Jack
Insertion direction
Body / insulator assembly
Backshell
Jack Disassembly
Insert the plug into securely held solder
termination fixture as shown.
Loosen the backshell turning it counter
clockwise and remove it from the body/
insulator assembly.
Insert the jack into the securely held solder
termination fixture as shown.
Loosen the backshell turning it
counterclockwise.
Notes
1
2Connector Assembly
(1)
(2)
(3)
Backshell
Threaded section
Tightening collar
Threaded section
1Apply a coating of Loctite 7649
(Manufactured by Henkel Japan, Ltd,) primer
to the threaded sections of the backshell and
the tightening collar. Completely dry the
coated surfaces.
Drying time at room temperature is
approximately 30 to 70 seconds.
Ensure sufficient ventilation of the area at
time of drying.
Take necessary steps to protect the coated
surfaces from contamination.
Fixture Part No.
Applicable connector
LF07BP-T01 LF07WBP-6S,6P,3S,3P
LF10BP-T01
LF13BP-T01
LF10WBP-4S,4P,12S,12P
LF13WBP-20S,20P,11S,11P
Fixture Part No.
Applicable connector
LF07BJ-T01 LF07WBJ-6S,6P,3S,3P
LF10BJ-T01
LF13BJ-T01
LF10WBJ-4S,4P,12S,12P
LF13WBJ-20S,20P,11S,11P
Tightening collar
Strain relief collar
Backshell
Gasket Cable
Cable preparation end
Note
Threading the components may not be
possible after the cable-end finishing process.
Note
When removing, assembling and wiring, be
sure to use a solder termination fixture.
Directly fixing the locking collar in place with
a vice etc.. could lead to damage,
deformation or lacuna of retaining ring.
Note
When removing, assembling and wiring, be
sure to use a solder termination fixture.
Directly fixing the body in place with a vice
etc.. could lead to damage or deformation.
Retaining ring
A Detail view
Note Vice fixed ban
Note Vice fixed ban
A
Vice
Vice
Vice
Vice
The connectors are delivered with pre-assembed condition and the disassembly as shown No.1.
Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved.
9
LF SeriesMiniature Waterproof Shielded Connectors
2– 2
2– 1
C mm
12
64
4
6
6
4
1to6
1to9
10to12
1to4
5to7
4
6
1to5,16to20
6to15
20
11
Table 3
Heat shrink tubing Dimensions
No. of
Conductors No. of contacts
3Cable preparation
Cable outer jacket
Shielding mesh
A
1
No.
1
Shielding mesh
(Folded back)
Wires Cable outer jacket 2
4 to 5mm
2
3
3
Table 2. Stripping Dimensions
Cable outer jacket
Wires
Shielding mesh
Cable outer jacket
B
Conductors
Wires
Stripping dimensions
Strip the cable’s outer jacket to the dimensions
illustrated in the table 1.
Fold back the shielding mesh over the cable’s
outer jacket assuring that it is uniform on its
diameter.
Strip the wires to the dimensions illustrated in
the Table 2.
Notes
(1)
(2)
Exercise caution not to damage the shielding
mesh.
Any damage to the cable’s outer jacket may
affect the waterproof performance of the
assembled connector.
Note
When stripping the wires exercise caution not
to damage it’s insulation, folded over
shielding mesh or cable’s outer jacket.
It may cause deffects in insulation,
conduction, and waterproof performance.
Illustration Operation
Table 1. Stripping Dimensions
No. of Conductors A mm
3
68 to 9
413 to 14
12
11
20
14 to 15
23 to 24
23 to 24 (No.1 to 7)
22 to 23 (No.A to D)
2±0.5
3±0.5
2±0.5
No. of Conductors B mm
3
6
2.5±0.5
4
12
11
20 2±0.5
2±0.5 (No.1 to 7)
3±0.5 (No.A to D)
Stripping dimensions
4Soldering
1Soldering conditions
Soldering iron tip temperature: 350±10ç
Soldering time: within 5 sec.
Notes
(1)
(2)
Assure that the solder compound is
sufficiently melted on the soldering iron tip.
When applying, make sure that the solder will
flow correctly at all the contact surfaces
between the conductor and the contact.
Insulator
Contact
Wire
C
Heat-shrink tubing
Solder
Insulator
0.5 mm min.
Wire insulation
Insulator wall
Contact
Insulator Insulator wall
Wire insulation
Contact
Place a heat-shrink tubing (inside diameter of
1.1 mm min.) over every other wire.
Perform the soldering of the contact and the
conductor, with the wire’s insulation touching
the contact as shown.
After soldering, slide the heat shrink tubing
over the soldered joint and shrink it. The
tubing should touch the insulator as shown.
Perform the soldering of the contact and the
conductor, with the wire’s insulation touching
the contact as illustrated.
When soldering, to maintain the insulation
between adjacent contacts. Make sure that
the wire’s insulation remains below the edge
of the insulator’s wall 0.5 mm min., as
illustrated.
– 2 3, 4, 11(No.AtoD) Conductors
2
(1)
(2)
2 – 1 6, 12, 11(No.1to7),20 Conductors
(1)
(2)
(3)
Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved.
10
LF SeriesMiniature Waterproof Shielded Connectors
No.
433
Shielding mesh
(Folded back)
DCable outer jacket After the soldering, keep a distance of D
between the contact end and the cable’s
outer jacket as illustrated.
Note
The distance of D is required in order to
assure correct assembly of the backshell.
Illustration Operation
No. of Conductors
3
6
D mm
6 to 7
4
18 to 19
12
10 to 11
13 to 14
11
20
Table 4. Wire Dimensions
2
1
3
Soldered joints
Cable outer jacket
Cable outer jacket
5 to 6mm
Cable outer jacket
Shielding mesh
Wires Copper tape
2 mm
max.
3
Copper tape
Copper tape
Wires
Copper tape
Overlap of the copper tape
Crimping of the Shielding Clamp
Solder termination fixture
Body / insulator assembly
2
1
1±0.5mm Cable outer jacket
Ground clamp
Shielding clamp
Shielding mesh
5
4
Commercially
available pliers
4
Overlap of the copper tape
E
Shielding clamp
After completion of the soldering operations
carefully remove (holding on the locking collar)
the body/insulator assembly from the solder
termination fixture.
Wrap the folded over shielding mesh with 5 to
6mm wide copper tape to assure that it will
not become loose.
Apply the copper tape so that the shielding
mesh does not protrude from under it.
Insert the “U” shaped shielding clamp over the
copper tape as shown on the illustration.
It is critical that the overlap of the copper tape
is located inside the shielding clamp as shown
on the illustration.
Using commercially available pliers bend the
open ends of the shielding clamp as illustrated,
assuring that it stays in place. The dimension
of E. between opposing edges of the shielding
clamp is necessary to assure correct final
crimp.
NoteExercise caution not to damage or deform the
solder joints.
Note
After wrapping the copper tape, the tape
should overlap itself by 2mm max.
Note
When the end of the copper tape wrapping is
positioned at the open side of the ground
fitting, the end portion of the copper tape
wrapping will no longer be covered by the
ground fitting when the ground fitting is
crimped.
Table 5
Shell size E
LF07
LF10
5mmmax.
7mmmax.
LF13
Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved.
11
LF SeriesMiniature Waterproof Shielded Connectors
No.
5
6
5
5
Note
It is critical that the protrusions are inside the
corresponding grooves.
It may cause breakage, when a tightening collar is assembled.
Forming cavity Crimping tool
5.3
7.0
Connector Assembly
12
,
Backshell
Threaded section
Wrench width : D
3
4
5
5
34
,
Tightening collar
Groove Protrusion
Strain relief collar
Gasket
Tightening collar
Threaded section
Both sides of the shielding clamp must be
placed in the forming cavity of the tool
(as shown on the illustration) and crimped
over the cable by closing the tool completely.
1Place the body/insulator assembly in the
applicable solder termination fixture.
Slide forward the gasket and insert it in
the backshell until fully seated.
Verify that the Locktite 7649 primer
(or equivalent) on the threaded sections of the
backshell and tightening collar are dry.
Apply the Locktite 263 compound to the
tightening collar’s threaded section and attach
it to the backshell.
Slide forward the strain relief collar and insert
it in the backshell, making sure that the
opposing protrusions fit inside the
corresponding grooves, as shown on the
illustration.
2Coat the thread section of the body/insulator
assembly with Loctite 263 compound
(manufactured by Henkel Japan, Ltd.) or
equivalent, tightening it with a torque
specified in the table 6.
Illustration Operation
Crimping tool
Forming cavity
Applicable
cable
diameter
Shielding clamp
diameter
after crimping
HR10A-TC-02
5.3 5mm
–––
7.3mm
8.7mm
5.3mm to
5.5mm
–––
7.9mm to
8.1mm
9.1mm to
9.3mm
7.0
LF-TC-01 7.9
9.1
Shell size Tightening torque Wrench width
LF07
LF10
10mm
1N·m to 1.5N·m
1N·m to 1.5N·m13mm
LF13 1.5N·m to 2N·m16mm
Table 6 (Recommend tightening torgue)
Fixture Part No. Applicable connector
Fixture Part No. Applicable connector
LF07BP-T01
LF10BP-T01
LF13BP-T01
LF07WBP-6S,6P,3S,3P
LF10WBP-4S,4P,12S,12P
LF13WBP-20S,20P,11S,11P
LF07BJ-T01
LF10BJ-T01
LF13BJ-T01
LF07WBJ-6S,6P,3S,3P
LF10WBJ-4S,4P,12S,12P
LF13WBJ-20S,20P,11S,11P
Locktite area
Wiring side 1 to 2 threaded portion
Body/insulator assembly
Notes
(1)
(2)
The applied loctite should not protrude out further
than the wiring side 1 to 2 threaded section. If it
does, it may affect waterproof performance and
locking. Please remove any protruding loctite
with a cloth or cotton swab. etc.
It is critical that the cable itself will not turn or
twist during this operation.
It may cause breakage at the soldered area.
For plug assembly
For jack assembly
Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved.
12
LF SeriesMiniature Waterproof Shielded Connectors
No.
66
6Remove the connector from the solder
termination fixture, holding it by the locking
collar. Do not pull on the cable.
It may cause breakage.
7
After connector assembly procedure is completed,
compress air in to the connector from the mating
side under 17.6 kPa for 30 seconds check that no
air leaks out of the connector.
Tightening collar
Illustration Operation
Shell size Tightening torque
Wrench width
LF07
LF10
LF13
10mm
0.8N·m to 1N·m
0.7N·m to 1N·m
1 N·m to 1.5 N·m
14mm
16mm
Wrench width
Recommended tightening torgue
Confirmation of Waterproof Performance
Remarks : The cable satisfies required specifications for UL specification.
Notes : The cable pull and twisting strength, waterproof tightness and other characteristics may differ, depending on the cable structure,
please confirm before the use.
󱽧Cable Specifications (Reference)
The characteristics and the specifications contained herein are for reference purpose. Please refer to the latest customer drawings prior to use.
The contents of this catalog are current as of date of 07/2018. Contents are subject to change without notice for the purpose of improvements.
2-6-3,Nakagawa Chuoh,Tsuzuki-Ku,Yokohama-Shi 224-8540,JAPAN
TEL: +81-45-620-3526 Fax: +81-45-591-3726
http://www.hirose.com
http://www.hirose-connectors.com
®
No. of contact 3 pos. 4 pos. 6 pos. 12 pos. 20 pos. 11 pos.
Conductor
Material Tin plated soft copper wire
Size (mm) Ø0.18 Ø0.26 Ø0.16 Ø0.16 Ø0.16 Ø0.26 Ø0.16
Construction
20 /Ø0.18 mm dia. 20 /Ø0.26 mm dia.
7 /Ø0.16 mm dia. 7 /Ø0.16 mm dia. 7 /Ø0.16 mm dia.
26 /Ø0.26 mm dia.
7 /Ø0.16 mm dia.
Size (AWG) 20 AWG 16 AWG 26 AWG 26 AWG 26 AWG 16 AWG 26 AWG
Sectional area
0.5 1.25 0.14 0.14 0.14 1.25 0.14
Diameter (mm)
Ø0.98 Ø1.5 Ø0.48 Ø0.48 Ø0.48 Ø1.5 Ø0.48
Insulator
Diameter (mm)
Ø1.5 (Standard) Ø2.1 (Standard) Ø0.88 (Standard) Ø0.9 (Standard) Ø0.9 (Standard)
Ø2.1 (Standard)
Ø0.95 (Standard)
Thickness (mm)
0.26 0.3 0.2 0.21 0.21 0.3 0.24
Shield
Material Tin plated soft copper wire
Density 85% 80% or more 85% 80% or more 80% or more 80% or more
Diameter (mm)
Ø3.6 Ø5.5 Ø3.4 Ø4.2 Ø5.1 Ø6.7
Jacket
Diameter (mm)
Ø5±0.2 Ø7.3±0.2 Ø5±0.2 Ø7.3±0.2 Ø8.7±0.2 Ø8.7±0.2
Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved.