Series 160 Compact Protection For Higher Current Ratings
Single-Pole High
Performance
Qualified
To MIL-C-5809 and MS25361.
Protection For Heavy-Duty
Systems
Protects circuits from 50 to 100
amperes.
Heavy-Duty Construction
Breaker features large contacts
and wide terminals.
Not Sensitive To Frequency
May be used on either AC or DC
circuits.
Performance Rated Circuit
Breaker
The 160 series has the recogni-
tion of being the most specified
heavy-duty aircraft type circuit
breaker in the 50 to 100 ampere
rating range.
Designed to protect heavy-duty
aircraft and non-aircraft electrical
systems, this trip-free breaker
features separate, durable, over-
load and mechanical latches. In
addition, the overload latch is
designed for precise operation.
Extra heavy contacts are spring-
loaded to maintain high-contact
pressure and assure long life.
Contact material has high resist-
ance to arcing and the corrosive
action of moisture —thus assur-
ing low voltage drop throughout
the life of the breaker.
OOVVEERRLLOOAADD CCAALLIIBBRRAATTIIOONN DDAATTAA
Specification @ 25°C @ +71°C @ -40°C Test Time
Table MIN MAX MIN MAX MIN MAX Parameters
Must Hold 105 70 125 % For 1 Hour
Must Trip 138 125 165 % Within 1 Hour
200% Overload 15 65 Seconds
400% Overload 2 10 Seconds
600% Overload 1 4 Seconds
Trip curve available.
PPEERRFFOORRMMAANNCCEE DDAATTAA
Interrupting Capacity 6,000A at 30V, DC; 3,500A at 120V, 400 Hz., AC
Endurance At 120VAC, 400 Hz.: inductive load — 5,000 cycles; resistive load — 5,000 cycles;
at 30V, DC: inductive load — 2,500 cycles; resistive load — 5,000 cycles;
mechanical cycling, no load — 5,000 cycles
Overload Cycling 100 operations at 200% rated current and rated voltage
Dielectric Strength At sea level, 25°C 1,500V, AC. At 70,000 ft., 71°C 500V, AC
Insulation Resistance Not less than 100 megohms at 500V, DC
Voltage Drop 0.15V, maximum
Vibration Meets specification MIL-STD-202, Method 204, Condition A–10G, 10–500 Hz.
MS “V” type series (160-086) meets Condition B 15G, 10–2,000 Hz., and Condition C 10g
10-2,000 Hz. (Random vibration also available)
Shock Exceeds 30G’s, 11 Millisec (half-sine pulse) MIL-STD-202, Method 213 Test J
Acceleration Exceeds 10G’s
Weight 113 grams (0.25 lbs.)
MS APPROVAL
STATUS
MS Approved
MS Approved
MS Approved
MS Approved
MS Approved
MS Approved
MS Approved
AMPERE
RATING
50
60
70
75
80
90
100
VOLTAGE
DROP
MAX. *
0.15
0.15
0.15
0.15
0.15
0.15
0.15
STANDARD
OORRDDEERRIINNGG IINNFFOORRMMAATTIIOONN
MS P/N
MS25361-50
MS25361-60
MS25361-70
MS25361-75
MS25361-80
MS25361-90
MS25361-100
EATON MP
P/N
160-012-50
160-012-60
160-012-70
160-012-75
160-012-80
160-012-90
160-012-100
HIGH VIBRATION
MS P/N
MS25361-50V
MS25361-60V
MS25361-70V
MS25361-75V
MS25361-80V
MS25361-90V
MS25361-100V
EATON MP P/N
160-086-50
160-086-60
160-086-70
160-086-75
160-086-80
160-086-90
160-086-100
* AT RATED NOMINAL CURRENT
3 Phase variants are available as a 940 Series.
For other amperage ratings and configurations, consult the Business Unit.
12 EATON CORPORATION Aerospace TF300-1 December, 2003
Standard
EATON CORPORATION Aerospace TF300-1 December, 2003 13
Series 160
DDIIMMEENNSSIIOONNSS
TTRRIIPP CCUURRVVEE
.500 ± .005 DIA.
#28 (.140) DIA.
2 PLACES
.906 ± .005
1.812 ± .010
RECOMMENDED MOUNTING
.750
MAX.
AMPERE RATING
IN WHITE FIGURES
.906
100
1.812
.138-32UNC-2B INTEGRAL
SELF LOCKING NUTS
(2 REQUIRED)
.485 MIN.
CLOSED
MOUNTING PLATE
1.580
MAX.
.735
.090
45
1.470
2.189 MAX.
2.250
MAX.
LINE TERMINAL
.250-28UNF-2AX.500L
CAP SCREW WITH FLAT
WASHER MS35308-303
LOCKING NUTS
2.047
.250
BLACK SLEEVE
.480 DIA.
.330 DIA.
.410
DIA.
.750
TRIPPED
WHITE TRIP
INDICATOR
BLACK
ACTUATOR
Time To Open (Trip) In Seconds
Percentage Of Circuit Breaker ’s Rated Current
10000
1000
100
00.1 1.0 10 100 1000 10000
TYPICAL
TRIP
CURVE
AT 25°C
138%
105%