Ultrasonic Sensors Compact 18 mm Diameter Digital FEATURES 1 Sensing distance up to 1,5 meters 1 18 mm diameter housing 940 Series 1 IP 67 sealing 1 High output current 1 High power transducer 1 Microprocessor controlled ORDER GUIDE Sensor Package Style Sensing Range* mm (in.) Digital Output Termination Catalog Listing 18 mm dia. 200 - 1500 PNP, N.O. Cable 940-F4Y-2D-001-180E PBTB Plastic (7.87 - 59.05) NPN, N.O. Cable 940-F4Y-2D-002-180E PNP, N.O. Connector cable 940-F4X-2D-001-180E NPN, N.O. Connector cable 940-F4X-2D-002-180E 150 - 700 PNP, N.O. Cable 940-F4Y-2D-001-300E (5.9 - 27.5) NPN, N.O. Cable 940-F4Y-2D-002-300E PNP, N.O. Connector cable 940-F4X-2D-001-300E NPN, N.O. Connector cable 940-F4X-2D-002-300E * Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam. SPECIFICATIONS Catalog Listings 940-F4Y-2D-001-180E 940-F4X-2D-001-180E 940-F4X-2D-002-180E 940-F4Y-2D-001-300E 940-F4Y-2D-002-300E 940-F4X-2D-001-300E 940-F4X-2D-002-300E Max. Sensing Distance 1500 mm (59.05 in.) 700 mm (27.5 in.) Min. Sensing Distance 200 mm (7.87 in.) 150 mm (5.91 in.) Beam Angle 8 8 www.DataSheet4U.com940-F4Y-2D-002-180E POWER SUPPLY Supply Voltage Supply Current 19 - 30 VDC <25 mA without load Circuit Protection <35 mA without load Reverse polarity OUTPUT CHARACTERISTICS Load Current 0 - 500 mA Switching Frequency 8 Hz 25 Hz Hysteresis 2% of setpoint 2.5% of setpoint Repeatability 1 mm Setpoint Adjustment 4-turn potentiometer Circuit Protection Short circuit ENVIRONMENTAL Operating Temperature - 15 to 70C (5 to 158F) Storage Temperature - 25 to 85C (- 13 to 185F) Sealing IP 67 SPECIAL FEATURES Hold Input Stops transmission and reception when input is connected to 0 VDC. Last output will be stored until input is disconnected Synchronization Input Avoids mutual interference from several sensors by interconnecting the hold input from each sensor. LED Indicator Illuminates when sensor detects target B82 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Sensors Compact 18 mm Diameter Digital 940 Series WIRING DIAGRAM 940-F4X/Y-20-001/2-300E Versions only 4-pin DC Micro (M12 x 1) Pin Color 1 BRN 2 PINK 3 BLU 4 BLK *Normal operation with no connection MOUNTING DIMENSIONS (For reference only) 940-F4X/Y-20-001/2-180E 940-F4X/Y-2D-001/2-300E ACCESSORIES www.DataSheet4U.com Catalog Listing Feature 43178389-018 Allows mounting to a flat surface Beam deflector 43192871-003 Allows right angle mounting (Approx. dim. 50 x 170 mm) Focusing beam deflector 43192871-004 Reduces beam angle by approximately 1/2 (Approx. dim. 35 x 52 mm) Straight connector w/o cable 66195044-001 Connector has screw terminals for wiring connection Right angle connector w/o cable 66195045-001 Connector has screw terminals for wiring connection 24 VDC Power supply, Relay output, 110 VAC input FF-MADB24RB See page B102 for more information 24 VDC POwer supply, On/Off delay, 110 VAC input FF-MADC24RB See page B102 for more information Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Proximity Mounting clamp B83 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Sensors 30 mm Diameter Analog 940 Series FEATURES 1 Measuring range up to 2000 mm (78.74 in.) 1 High repeatability ORDER GUIDE Sensor Package Style Sensing Range* mm (in.) 30 mm dia. Stainless Steel Analog Output Termination Catalog Listing 300 - 2000 (11.81 - 78.74) 1.5 - 10 V Cable 940-A4Y-AD-1C0-130E 150 - 1200 1.25 - 10 V Cable 940-A4Y-AD-1C0 Connector 940-A4V-AD-1C0 (5.90 - 47.24) * Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam. SPECIFICATIONS Catalog Listings www.DataSheet4U.com Max. Sensing Distance 940-A4Y-AD-1C0 940-A4V-AD-1C0 940-A4Y-AD-1C0-130E Max. Range Max. Rate Max. Range Max. Rate 2000 mm (78.74 in.) 1000 mm (39.37 in.) 1200 mm (47.2 in.) 600 mm (23.6 in.) Min. Sensing Distance Beam Angle 300 mm (11.8 in.) 150 mm (5.91 in.) 8 10 POWER SUPPLY Supply Voltage 19 - 30 VDC Supply Current <20 mA without load Circuit Protection Reverse polarity OUTPUT CHARACTERISTICS Load Current Switching Frequency Repeatability 10 mA max. 6 Hz 11 Hz 2 mm 1 mm Linearity <0.2% Output Adjustment Output Mode 4 Turn Potentiometer Max. Range or Max. Rate selected by wiring terminal connection Circuit Protection Short Circuit ENVIRONMENTAL Operating Temperature 0 to 50C (32 to 122F) Storage Temperature 0 to 70C (32 to 158F) Sealing IP 65 SPECIAL FEATURES Hold Input Stops transmission and reception of sensor when input is connected to 0 VDC. Analog output would be zero. Synchronization Input Avoids mutual interference from several ultrasonic sensors (external synchronization unit required; see Accessories) LED Indicator Illuminates when sensor detects a target B84 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Sensors 30 mm Diameter Analog 940 Series CONNECTOR VERSION ONLY WIRING DIAGRAM Pin 1 2 3 4 5 Color BRN WHT BLU BLK GRAY *Normal operation with connection +19-30 VDC 940-A4Y-AD-1C0-130E 940-A4Y-AD-1C0 MOUNTING DIMENSIONS (For reference only) 940-A4V-AD-1C0 www.DataSheet4U.com Proximity ACCESSORIES Catalog Listing Feature Mounting clamp, 30 mm sensor 43178389-030 Allows mounting to a flat surface Beam deflector 43192871-001 Allows right angle mounting (Approx. dim. 50 x 170 mm) Focusing beam deflector 43192871-002 Reduces beam angle by approximately 1/2 Compact deflector 66195116-001 Allows right angle mounting (Approx. dim. 35 x 52 mm) 2 meter cable, Straight connector RKT5-612/2M Used for wiring to connector version 5 meter cable, Straight connector RKT5-612/5M Used for wiring to connector version 2 meter cable, Right angle connector RKWT5-612/2M Used for wiring to connector version 5 meter cable, Right angle connector RKWT5-612/5M Used for wiring to connector version Synchronization unit 55000001 Controls up to 100 sensors Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada B85 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Sensors Compact 30 mm Diameter Analog and Digital, RS232/RS485 Interface FEATURES 1 Programmable 1 RS232 or RS485 interface 942 Series 1 0 - 10 VDC/4 - 20 mA output 1 Two N.O. PNP outputs or one N.O. PNP/one N.C. PNP output ORDER GUIDE Sensor Package Style Sensing Range* mm (in.) Analog Output 30 mm dia. 300 - 3000 0 - 10 V PNP, N.O./N.C. RS232 942-A4N-2D-1C1-130E Stainless Steel (11.8 - 118) 4 - 20 mA PNP, N.O./N.C. RS232 942-A4N-2D-1D1-130E 272,1g (9.6 oz) Digital Output Interface Catalog Listing 0 - 10 V PNP, N.O./N.C. RS485 942-A4N-2D-1E1-130E 4 - 20 mA PNP, N.O./N.C. RS485 942-A4N-2D-1F1-130E 150 - 1500 0 - 10 V PNP, N.O./N.C. RS232 942-A4N-2D-1C1-220S (5.9 - 59.1) 4 - 20 mA PNP, N.O./N.C. RS232 942-A4N-2D-1D1-220S 100 - 600 (3.94 - 23.6) 0 - 10 V PNP, N.O./N.C. RS485 942-A4N-2D-1E1-220S 4 - 20 mA PNP, N.O./N.C. RS485 942-A4N-2D-1F1-220S 0 - 10 V PNP, N.O./N.C. RS232 942-A4N-2D-1C1-300E * Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam. www.DataSheet4U.com SPECIFICATIONS Catalog Listings 942-A4N-2D-1C1-130E 942-A4N-2D-1D1-130E 942-A4N-2D-1E1-130E 942-A4N-2D-1F1-130E 942-A4N-2D-1C1-220S 942-A4N-2D-1D1-220S 942-A4N-2D-1E1-220S 942-A4N-2D-1F1-220S 942-A4N-2D-1C1-300E Max. Sensing Distance 3000 mm (118 in.) 1500 mm (59.1 in.) 600 mm (23.6 in.) Min. Sensing Distance 300 mm (11.8 in.) 150 mm (5.91 in.) 100 mm (3.94 in.) Beam Angle 8 10 8 POWER SUPPLY Supply Voltage 19 - 30 VDC Supply Current < 30 mA without load Circuit Protection Reverse Polarity OUTPUT CHARACTERISTICS (DIGITAL) Load Current 0 - 100 mA Hysteresis Programmable (0 - 255 mm) Switching Frequency Programmable 5-30 Hz Programmable 5-30 Hz Repeatability Programmable 5-50 Hz 2 mm or 0.4% of reading Setpoint Adjust Programmable within sensing range Circuit Protection Short circuit OUTPUT CHARACTERISTICS (ANALOG) Switching Frequency Programmable 5-30 Hz Programmable 5-30 Hz Repeatability Programmable 5-50 Hz 2 mm or 0.4% of reading Linearity 3 mm or 0.5% Output Adjust Programmable Circuit Protection Short circuit ENVIRONMENTAL Operating Temperature - 15 to 70C (5 to 150F Storage Temperature - 25 to 85C (- 13 to 185F) Sealing IP 65 SPECIAL FEATURES Hold Input Stops transmission and reception when input is connected to 0 VDC. Analog output would be zero. Synchronization input Avoids mutual interference from several sensors by interconnecting the Hold input from each sensor. LED Indicator Illuminates when sensor detects target Programmable Parameters Analog Output: Span, Offset, Positive or Negative slope Digital Output: Hysteresis, N.O./N.C. B86 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Sensors Compact 30 mm Diameter Analog and Digital, RS232/RS485 Interface 942 Series WIRING DIAGRAM *Normal operation with no connection MOUNTING DIMENSIONS (For reference only) www.DataSheet4U.com Proximity ACCESSORIES Mounting clamp Catalog Listing Features 43178389-030 Allows mounting to flat surface Beam deflector 43192871-001 Allows right angle mounting (approx. dim. 50 x 170 mm) Focusing beam deflector 43192871-002 Reduces beam angle by approximately 50% Compact deflector 66195116-001 Allows right angle mounting (approx. dim. 35 x 52 mm) Programming adapter 55000005-002 Allows sensor programming via RS232 interface RS232/RS485 converter 55000003-001 Converts RS232 interface to RS485 interface 24 VDC Power supply, relay output, 110 VAC input FF-MADB24RB See page B102 more information 24 VDC Power supply, On/Off delay, 110 VAC input FF-MADC24RB See page B102 more information Software package (disk, manual, cable + 1 sub min D9 connector) 55195101-101 Allows programming of sensor Software package (disk, manual, cable + 2 sub min D9 connectors) 55195101-102 Allows programming of sensor Straight connector 66195126-001 Used for wiring to connector 2 meter cable with straight connector 55195126-001 Used for wiring to connector Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada B87 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Sensors 2-Piece 30 mm Diameter Precision Switching, Analog, Digital BCD, Hexadecimal Outputs FEATURES 1 Background suppression 1 Sensor sealed to IP 65 1 Amplifier sealed to IP 54 1 DIN rail mounting 942 Series 1 Compensated over 0 to 50C (32 to 120F) 1 Amplifier provides analog, digital switching, BCD or hexadecimal outputs ORDER GUIDE Sensor Package Style Sensing Range* mm (in.) Digital Output** 30 mm (1.18 in.) Stainless steel sensor head 150 - 1500 (5.9 - 59.0) Two PNP N.O. or N.C. Multiplex Digital Output BCD/HEX Analog Output Catalog Listing*** 0 - 10 VDC 4 - 20 mA 942-M3A-2D-1G1-220S *Standard target: 120 mm thick square of mild steel perpendicular to ultrasonic beam. **N.O./N.C. output selectable ***Includes stainless steel sensor head, cable, straight connector and amplifier. 272g (9.6 oz) www.DataSheet4U.com SPECIFICATIONS Max. Sensing Distance 1500 mm (59.1 in.) Min. Sensing Distance 150 mm (5.91 in.) Beam Angle 10/5 POWER SUPPLY Supply Voltage 19-30 VDC Supply Current <130 mA without load Circuit Protection Reverse polarity OUTPUT CHARACTERISTICS (DIGITAL) Load Current 0-100 mA Hysteresis 1% of setpoint Switching Frequency 8 Hz Repeatability 1 mm or 0.2% of reading Setpoint Adjustment Digital switches Output Adjustment Beam angle 10 w/max. sensitivity or beam angle 5 w/min. sensitivity Circuit Protection Short circuit OUTPUT CHRACTERISTICS (MULTIPLEX DIGITAL) Resolution 1 mm Information Output Bit Parallel/Word Serial Setpoint Adjustment Beam angle 10 w/max. sensitivity or beam angle 5 w/min. sensitivity OUTPUT CHARACTERISTICS (ANALOG) Switching Frequency Repeatability Linearity 8 Hz 1 mm or 0.2% of reading 2 mm or 0.3% Output Range Adjustment Output Adjustment Min. Load Resistance (VDC) Max. Load Resistance (mA) Slope of Output Digital switches Beam angle 10 w/max. sensitivity or beam angle 5 w/min. sensitivity 1000 Ohms (0-10 VDC output) 250 Ohms (4-20 mA output) Positive or Negative via switch ENVIRONMENTAL Operating Temperature Storage Temperature Sealing Sensor head: 0 to 70C (32 to 158F)/Amplifier: 0 to 50C (32 to 122F) Sensor head/Amplifier: - 25 to 85C (- 13 to 185F) Sensor Head: IP 65/Amplifier: IP 54 SPECIAL FEATURES LED Indicators RED - Under Range/ RED - Over Range: illumination dependent on analog range chosen and target position with respect to sensor YELLOW - Setpoint: illuminates when target reaches setpoint 1 or setpoint 2 Hold Input Stops transmission and reception when input is connected to 0 VDC. Last output stored until input is disconnected Synchronization Input Avoids mutual interference from several sensors by interconnecting the hold input from each sensor B88 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Sensors 2-Piece 30 mm Diameter Precision Switching, Analog, Digital BCD, Hexadecimal Outputs WIRING DIAGRAM PWS 1 19-30 V 2 GND Sensor head 3 19-30 V 4 GND 5 STA 6 STO 7 SEN 8 TEM RM CO 9 GND 10 HLD Outputs 11 GND 12 ORA 13 URA 14 SP1 15 SP2 Analog out 16 V 17 GND 18 I Digital out www.DataSheet4U.com 103 102 101 100 23 22 21 20 External supply terminals MOUNTING DIMENSIONS (For reference only) 19-30 V supply 0 V line Sensor head terminals +Vs supply voltage 0 V line Signal transmit command Stop signal, echo received Receive sensitivity Temperature sensor Transmit control 0 V line Transmit inhibit, synchronize Switching outputs 0 V line No echo, out of range Under range, target too close Switching output 1 Switching output 2 Analog outputs V out, 0-10 V 0 V line Current out, 4-20 mA Multiplexed digital outputs 1000 decade strobe 100 decade strobe 10 decade strobe 1 decade strobe 8 BCD/HEX 4 BCD/HEX 2 BCD/HEX 1 BCD/HEX Proximity 23 24 25 26 27 28 29 30 942 Series ACCESSORIES Mounting clamp Catalog Listing Features 43178389-030 Allows mounting to flat surface Beam deflector 43192871-001 Allows right angle mounting (approx. dim. 50 x 170 mm) Focusing beam deflector 43192871-002 Reduces beam angle by approximately 50% Compact deflector 66195116-001 Allows right angle mounting (approx. dim. 35 x 52 mm) REPLACEMENT LISTINGS Sensor Head 942A4M-2D-K220S Amplifier 942-M0A-2D-1G1-220S Straight Connector (cable not included) 66195074-001 942 SERIES ULTRASONIC CROSS REFERENCE Obsolete Listing Replacement Listing Comments 942-M88 942-M88-LF 942-M96 Sensor head, includes connector 942-M3A-2D-1G1 942-M0A-2D-1G1-220S Amplifier Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada B89 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Temperature Sensors Platinum RTDs HRTS Series FEATURES 1 Resistance interchangeable 1 Accurate 1 Linear 1 Fast 1 Laser trimmed 1 Bolt, cement-on or strap-on models TYPICAL APPLICATIONS 1 HVAC - room, duct and refrigerant equipment 1 OEM assemblies 1 Electronic assemblies - semiconductor protection, temperature compensation 1 Process control - temperature regulation www.DataSheet4U.com ORDER GUIDE HRTS-5760-B Miniature, ceramic body, 28 ga TFE Teflon insulated leads (2-wire only) HRTS-61 Bolt-on, nickel plated copper alloy body, 24 ga fiberglass insulated leads, SST braid, TFE overwrap, spiral armor -T -U The HRTS is designed to measure surface temperatures from -200 to +480C (-320 to +900F) in printed circuit, temperature probe, or other applications. HRTS surface temperature sensors are fully assembled elements, ready to use, without the need for fragile splices to extension leads. A thin layer of platinum is deposited on an alumina substrate and laser trimmed to a resistance interchangeability of 0.2% with 0.5C accuracy or 0.1% with 0.3C accuracy. The sensor chip is then glassed, wired and potted or ceramic fired to result in a cylindrical alumina package with either Teflon or fiber glass insulated lead wires. Fig. 1: Wheatstone Bridge 2-Wire Interface 100V, 0.00385 V/V/C, 3-wire leads, DIN specification 1000V, 0.00375 V/V/C, 2-wire leads -0 0.2% Resistance Trim (Standard) -1 0.1% Resistance Trim (Optional) -12 Standard length, HRTS-5760-B -24 Standard length, HRTS-61 Fig. 2: Linear Output Voltage MOUNTING DIMENSIONS (for reference only) HRTS-5760-B Fig. 3: Adjustable Point (Comparator) Interface Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Temperature HRTS-61 93 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Temperature Sensors Platinum RTDs HRTS Series FUNCTIONAL BEHAVIOR RT J R0(1+AT+BT2-100CT3+CT4) RT J Resistance (V) at temperature T (C) R0 J Resistance (V) at 0C T J Temperature in C AJa+ ad BJ -ad CT<0 J - a b 100 1002 1004 ACCURACY VS TEMPERATURE HRTS platinum RTDs are available in two base resistance trim tolerances: 0.2% or 0.1%. The corresponding resistance interchangeability and temperature accuracy for these tolerances are: Tolerance Standard 0.2% Optional 0.1% Temperature (C) DR* (V) DT (C) DR* (V) DT (C) -200 6.8 1.6 5.1 1.2 CONSTANTS -100 2.9 0.8 2.4 0.6 0 2.0 0.5 1.0 0.3 1.4999 0.007 100 2.9 0.8 2.2 0.6 0.10863 200 5.6 1.6 4.3 1.2 300 8.2 2.4 6.2 1.8 -5.775x10-7 400 11.0 3.2 8.3 2.5 -4.183x10 500 12.5 4.0 9.6 3.0 600 15.1 4.8 10.4 3.3 Alpha, a (C-1) 0.00375 0.000029 0.003850 0.000010 Delta, d (C) 1.605 0.009 Beta, b (C) 0.16 A (C ) 3.81x10 B (C-2) -6.02x10-7 C (C ) -6.0x10 -1 3.908x10 -3 -4 -12 Both b J 0 and C J 0 for T>0C www.DataSheet4U.com -3 -12 *1000V RTD. Divide DR by 10 for 100V RTD. RESISTANCE VS TEMPERATURE CURVE CAUTION PRODUCT DAMAGE The inherent design of this component causes it to be sensitive to electrostatic discharge (ESD). To prevent ESD-induced damage and/or degradation, take normal ESD precautions when handling this product. SPECIFICATIONS Sensor Type Thin film platinum RTD: Ro J 1000 V @ 0C; alpha J 0.00375 V/V/C Ro J 100 V @ 0C; alpha J 0.00385 V/V/C Temperature Range HRTS-5760-B: -200 to +260C (-320 to +500F) HRTS-61: -75 to +425C (-100 to +800F) Temperature Accuracy 0.5C or 0.8% of temperature @ 0.2% Ro Trim 0.3C or 0.6% of temperature @ 0.1% Ro Trim Optional Time Constant, 1/e HRTS-5760-B: Typically 0.6 sec. on metal surfaces HRTS-61: Typically 20 sec. On metal surfaces Operating Current 2 mA max. for self-heating errors of 1C 1 mA recommended Self-Heating 0.3 mW/C Lead Material Nickel coated stranded copper, Teflon or Fiberglass insulated 94 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Sensors Precision Digital 18 mm Diameter FEATURES 1 Background suppression 1 Sealed to IP 65 1 Fixed or adjustable setpoint control 945 Series 1 Temperature compensation over 0 to 50C (32 to 122F) 1 Inhibit/synchronization input 1 Stainless steel or plastic housings ORDER GUIDE Sensor Package Style Sensing Range* mm (in.) Setpoint Output Type Catalog Listing 18 mm dia. 100 - 500 Fixed @ 400 mm (15.75 in.) 20 mm** PNP, N.O. 945-F4Y-AD-001 Plastic (3.9 - 19.68) NPN, N.O. 945-F4Y-AD-002 100 - 200 Fixed @ 200 mm (7.87 in.) 20 mm** (3.9 - 7.87) PNP, N.O. 945-N4Y-AD-001 NPN, N.O. 945-N4Y-AD-002 200 - 500 (7.87 - 19.68) Setpoint adjustment within sensing range PNP, N.O. 945-F4Y-AD-001-180E 70 - 180 (2.76 - 7.09) Setpoint adjustment within sensing range PNP, N.O. 945-F4Y-AD-001-300E 18 mm dia. 100 - 500 Setpoint adjustment within sensing range PNP, N.O. 945-L4Y-AD-001 Stainless Steel (3.9 - 19.68) 90,7 g (3.2 oz.) 100 - 200 www.DataSheet4U.com Setpoint adjustment within sensing range (3.9 - 7.87) NPN, N.O. 945-L4Y-AD-002 PNP, N.O. 945-S4Y-AD-001 NPN, N.O. 945-S4Y-AD-002 136 g (4.8 oz.) * Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam. **External setpoint adjustment wiring possible. SPECIFICATIONS SENSING CHARACTERISTICS Catalog Listings 945-F4Y-AD-001 945-F4Y-AD-002 945-L4Y-AD-001 945-L4Y-AD-002 945-N4Y-AD-001 945-N4Y-AD-002 945-S4Y-AD-001 945-S4Y-AD-002 945-F4Y-AD-001-180E 945-F4Y-AD-001-300E Max. Sensing Distance Min. Sensing Distance 500 mm (19.66 in.) 200 mm (7.87 in.) 500 mm (19.66 in.) 180 mm (7.09 in.) 100 mm (3.9 in.) 100 mm (3.9 in.) 200 mm (7.87 in.) Beam Angle 70 mm (2.76 in.) 10 10 8 8 POWER SUPPLY Supply Voltage Supply Current 19 - 30 VDC <30 mA without load <25 mA without load Circuit Protection Reverse polarity OUTPUT CHARACTERISTICS Load Current 0 - 100 mA Hysteresis 10 mm Switching Frequency 30 Hz Repeatability 0.5 mm or 0.3% or reading Setpoint Adjustment 60 Hz 25 Hz 60 Hz 0.2 mm or 0.2% or reading (Fixed or External Circuit) or 4 Turn Potentiometer Circuit Protection Short Circuit ENVIRONMENTAL Operating Temperature 0 to 50C (32 to 122F) Storage Temperature 0 to 70C (32 to 150F) Sealing IP 65 SPECIAL FEATURES Hold Input Stops transmission and reception when input is connected to 0 VDC. Last output will be stored until input is disconnected Synchronization Input Avoids mutual interference from several sensors. (External synchronization unit is required. See Accessories) LED Indicator Illuminates when sensor detects target B90 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Sensors Precision Digital 18 mm Diameter 945 Series WIRING DIAGRAMS 945-F/N Series 945-L/S Series *Normal operation with no connection *Normal operation with no connection MOUNTING DIMENSIONS (For reference only) 945-F/N Series plastic Housing 945-L/S Series Stainless Steel Housing www.DataSheet4U.com Proximity ACCESSORIES Catalog Listing Features 24 VDC Power supply, relay output, 110 VAC input FF-MADB24RB See page B102 for more information 24 VDC Power supply, ON/OFF delay, 110 VAC input FF-MADC24RB See page B102 for more information Synchronization unit 55000001 Controls up to 100 sensors Mounting clamp, 18 mm housing 43178389-018 Allows mounting to a flat surface Beam deflector 43192871-003 Allows right angle mounting (approx. dim. 50 x 170 mm) Focusing beam deflector 43192871-004 Reduces beam angle by approximately 50% Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada B91 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Sensors Precision Analog 18 mm Diameter FEATURES 1 Background suppression 1 Sealed to IP 65 1 Adjustable sensitivity 945 Series 1 Temperature compensation over 0 to 50C (32 to 122F) 1 Inhibit/synchronization input 1 Stainless steel or plastic housings ORDER GUIDE Sensor Package Style Sensing Range* mm (in.) 18 mm dia. Plastic Analog Output Catalog Listing 150 - 600 (5.9 - 23.6) 1.5 - 6 V 945-F4Y-AD-1C0-180E 60 - 200 (2.36 - 7.87) 1.8 - 6 V 945-F4Y-AD-1C0-300E 100 - 600 (3.9 - 23.6) 1-6V 945-L4Y-AD-1C0 18 mm dia. Plastic with Stainless Steel or Plastic External 150 - 600 (5.9 - 23.6) 1.5 - 6 V Head 945-E3Y-AD-1C0-180E (M18 x 1 stainless steel sensor head) 30 - 150 (1.18 - 5.9) 0.9 - 4.5 V 945-G3Y-AD-1C0-300E (M12 x 1 plastic sensor head) 90,7 g (3.2 oz.) 18 mm dia. Stainless Steel www.DataSheet4U.com 136 g (4.8 oz.) SPECIFICATIONS Catalog Listings 945-F4Y-AD-1C0-180E 945-F4Y-AD-1C0-300E 945-L4Y-AD-1C0 945-E3Y-AD-1C0-180E 945-G3Y-AD-1C0-300E Max. Sensing Distance 600 mm (23.6 in.) 200 mm (7.87 in.) 600 mm (23.6 in.) 600 mm (23.6 in.) 150 mm (5.9 in.) Min. Sensing Distance 150 mm (5.9 in.) 60 mm (2.36 in.) 100 mm (3.9 in.) 150 mm (5.9 in.) 30 mm (1.18 in.) Beam Angle 8 8 10 8 8 10 Hz 20Hz POWER SUPPLY Supply Voltage 19 - 30 VDC Supply Current <20 mA without load Circuit Protection Reverse polarity OUTPUT CHARACTERISTICS Load Current Switching Frequency 10 mA max. 10 Hz 20 Hz Repeatability 10 Hz < 0.3% of reading Linearity <0.2% Output Adjustment 4 turn potentiometer Circuit Protection Short Circuit ENVIRONMENTAL Operating Temperature 0 to 50C (32 to 122F) Storage Temperature 0 to 70C (32 to 158F) Sealing IP 65 SPECIAL FEATURES Hold Input Stops transmission and reception of sensor when input is connected to 0 VDC. Analog output would be zero VDC Synchronous Input Avoids mutual interference from several ultrasonic sensors (external synchronization unit is required; see accessories) LED Indicator Illuminates when sensor detects a target B92 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Sensors Precision Analog 18 mm Diameter 945 Series WIRING DIAGRAMS 945-F/L, 945-E/G Series *Normal operation with connection to 19-30 VDC MOUNTING DIMENSIONS (For reference only) 945-F/L Series Housing 945-E/G Series with External Head www.DataSheet4U.com Proximity ACCESSORIES Catalog Listing Features Synchronization unit 55000001 Controls up to 100 sensors Mounting clamp, 18 mm housing 43178389-018 Allows mounting to flat surface Beam deflector 43192871-003 Allows right angle mounting (approx. dim. 50 x 170 mm) Focusing beam deflector 43192871-004 Reduces beam angle by approximately 50% Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada B93 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 94X Series (942-O4N-2D-1A1/1A2-80E, 943-O4V-2D-001/002/1C0/1D0-80E, 947-O4V-2D-1C0/1D0-80E) www.DataSheet4U.com Ultrasonic Distance Sensors DESCRIPTION This collection of ultrasonic devices offers enhanced sensing range capability in a square plastic housing. Available sensor types include programmable, Teach-In, and analogue and fixed output versions. FEATURES * * POTENTIAL APPLICATIONS Non contact distance sensing for use in non invasive * Level measurement measurement * Presence/absence detection Reduced sensitivity to light intensity/reflectivity/opacity of * Distance measurement target for enhanced flexibility and certainty of measurement * Detects over much longer distance than other detection methods reducing the need for close proximity to the target * Extremely long sensing distance (up to 6 m [19.65 ft]) reducing the need for close proximity measurement which can be critical for some applications Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 943 Series (942-O4N-2D-1A1/1A2-80E, 943-O4V-2D-001/002/1C0/1D0-80E, 947-O4V-2D-1C0/1D0-80E) Specifications Parameter 942-O4N-2D1A1-80E Max. sensing distance Min. sensing distance Expected response time 90% of final value Beam angle Switching frequency Linearity error Hysteresis Repeatability of measured distance Temperature range Temperature compensation Operating voltage Expected current consumption Analogue output www.DataSheet4U.com Analogue output selection by load Switching outputs Expected output current Adjustment Alignment LED Status switching output 1 Status switching output 2 Control input Inhibit connect to: Synchronisation connect to: Enable connect to: Interface Plastic housing Sealing* Connector 942-O4N-2D1A2-80E 943-O4V-2D001-80E 943-O4V-2D002-80E 250 ms/prog 6000 mm [236.22 in] 600 mm [23.62 in] - 7 Hz/prog <0.3% prog 0.2% 8 0.5 Hz - ~1% - 943-O4V-2D1C0-80E 943-O4V-2D1D0-80E 700 ms 947-O4V-2D947-O4V-2D1C0-80E 1D0-80E 5000 mm [196.85 in] 500 mm [19.69 in] 400 ms 10 7 Hz/prog <0.5 % - 0.2% 2 mm [0.08 in] 0.2% -15 C to 70 C [-5 F to 158 F] yes 12 Vdc to 30 Vdc 15 Vdc to 30 Vdc <80 mA <35 mA - 0 V to 10 V 4 mA to 20 mA - 15 Vdc to 30 Vdc 100 mA 0 V to 10 V/4 mA to 20 mA load >2 kOhm Uout load <500 Ohm Iout 2 PNP NO/NC 2 NPN NO/NC 2 PNP NO/NC 2 NPN NO/NC 100 mA max. 500 mA max. programming Teach-In green (1) yellow (2) yellow (3) - Pin 6 0 V Pin 6 Pin 6 Pin 6 NC RS232 - 24 Vdc 20% <40 mA 0 V to 10 V 4 mA to 20 mA - - - - Pin 2 0 V Pin 2 Pin 2 Pin 2 NC - PBPT IP65 8 pin M16x0.75 5 pin M12x1 *Attention! Do not expose sensor head to hot water >50 C or steam vapour. Accessories: 942-O4N-2D-1A1/1A2-80E Catalog Listing Description 66195126-001 Mating connector straight 55000005-002 Programming adaptor 55000010-001 Software programming adaptor and PC connection cable 55000018-001 Programming cable Accessories: 943-O4V-2D-001/002-80E, 943-O4V-2D-1C0/1D0-80E, 947-O4V-2D-1C0/1D0-80E Catalog Listing Description 66195044-001 Mating connector straight 66195045-001 Mating connector angled 66195214-001 Straight cable/connector 2 m 66195216-001 Right-angle cable/connector 2 m 2 www.honeywell.com/sensing Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Distance Sensors Mounting Dimensions (For reference only. mm/[in]) 942-O4N-2D-1A1/1A2-80E 943-O4V-2D-001/002/1C0/1D0-80E, 947-O4V-2D-1C0/1D0-80E www.DataSheet4U.com Wiring P42-O4N-2D-1A1/1A2-80E View to solder pins of connector 943-O4V-2D-001-80E Pin 1: + 24 Vdc 5 3 2 Pin 5 Teach-In 4 Switching output SP1 3 5 Pin 2 Pin 4: SP1 6 +24 Vdc Pin 4 Pin 3: U/I 1 8 7 Pin 2: GND 4 Pin 1 Switching output SP2 Pin 5: SP2 1 R 2 R Pin 3 Pin 6: Hld/Sync 0V Pin 7: RxD Pin 8: TxD 943-O4V-2D-002-80E 943-O4V-2D-1C0/1D0-80E Pin 1 Pin 2 Pin 4 +24 Vdc Switching output 2 Pin 1 Load 4 Switching output 1 3 1 Teach-In Pin 3 2 Pin 5 Teach-In Pin 3 0 V/GND 947-O4V-2D-1C0-80E Pin 1 +24 Vdc Pin 4 Analogue output Pin 3 Analogue 5 2 0V 947-O4V-2D-1C0/1D0-80E Pin 2 3 4 Pin 4 1 5 Pin 5 +24 V Load 947-O4V-2D-1D0-80E 20 mA 10 V Enable Synchronisation Inhibit 4 3 1 2 4 mA 0V 500 mm 5000 mm 500 mm 5000 mm 0V Honeywell Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Detection Range 942-O4N-2D-1A1/1A2-80E, 943-04V-2D-001/002/1C0/1D0-80E 947-04V-2D-1C0/1D0-80E +600 +1000 mm mm -600 -1000 0 600 0 6000 mm 500 mm 5000 Enhanced detection of a target 100 mm x 100 mm Enhanced detection of a target 100 mm x 100 mm Possible detection of a large target Possible detection of a large target WARNING WARNING PERSONAL INJURY MISUSE OF DOCUMENTATION DO NOT USE these products as safety or emergency stop * devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in www.DataSheet4U.com death or serious injury. The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. * Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of SALES AND SERVICE defective materials and faulty workmanship. Honeywell's Honeywell serves its customers through a worldwide network standard product warranty applies unless agreed to otherwise of sales offices, representatives and distributors. For by Honeywell in writing; please refer to your order application assistance, current specifications, pricing or name acknowledgement or consult your local sales office for specific of the nearest Authorized Distributor, contact your local sales warranty details. If warranted goods are returned to Honeywell office or: during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The E-mail: info.sc@honeywell.com foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of Internet: www.honeywell.com/sensing merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, Phone and Fax: or indirect damages. Asia Pacific +65 6355-2828 While we provide application assistance personally, through Europe +44 (0) 1698 481481 +65 6445-3033 Fax our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax application. USA/Canada +1-800-537-6945 Specifications may change without notice. The information we +1-815-235-6847 supply is believed to be accurate and reliable as of this +1-815-235-6545 Fax printing. However, we assume no responsibility for its use. Automation and Control Solutions Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, MN 55422 www.honeywell.com/sensing 004451-1-EN IL50 GLO Printed in USA February 2006 Copyright (c) 2006 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 943 Series Ultrasonic Distance Sensors The new 943 series industrial sensors are the latest addition to our product range. They have improved scanning ranges, remote teach in of the switching or analog outputs, as well as new advanced features, such as window and hysteresis modes. M30 CONNECTOR www.DataSheet4U.com 11,2 M30 x 1,5 5,0 CABLE 123,5 0,5 90 0,5 2000 100 Analogue voltage output 0-10 V and 4-20 mA 2 switching outputs PNP NO and NPN NO Beam angle: Supply voltage: Sealing: 8 12 to 30 V IP67 Beam angle: Supply voltage: Sealing: 8 15 to 30 V IP67 M30 M30 Housing: M30 x 1,5 mm plastic (PBTB) Max. sensing distance: 3500 mm Min. sensing distance: 300 mm Switching frequency: 1.0 Hz Repeatability: 0,2 % or 2 mm Housing: M30 x 1,5 mm plastic (PBTB) Max. sensing distance: 3500 mm Min. sensing distance: 300 mm Response time: 400 ms Repeatability: 0,2 % or 2 mm OUTPUT PNP, 2 NO/NC PNP, 2 NO/NC NPN, 2 NO/NC NPN, 2 NO/NC OUTPUT 0-10 V 0-10 V 4-10 mA 4-20 mA TERMINATION Connector Cable Connector Cable REFERENCE 943-T4V-2D-001-130E 943-T4Y-2D-001-130E 943-T4V-2D-002-130E 943-T4Y-2D-002-130E TERMINATION Connector Cable Connector Cable REFERENCE 943-T4V-2D-1C0-130E 943-T4Y-2D-1C0-130E 943-T4V-2D-1D0-130E 943-T4Y-2D-1D0-130E M30 x 1,5 5,0 OPTIONS AND ORDER GUIDE M18 CONNECTOR 3,5 CABLE M18 Housing: M18 x 1,0 mm plastic (PBTB) Max. sensing distance: 2000 mm Min. sensing distance: 200 mm Switching frequency: 1.2 Hz Repeatability: 0,2 % or 2 mm Housing: M18 x 1,0 mm plastic (PBTB) Max. sensing distance: 2000 mm Min. sensing distance: 200 mm Switching frequency: 250 ms Repeatability: 0,2 % or 2 mm OUTPUT PNP, 2 NO/NC PNP, 2 NO/NC NPN, 2 NO/NC NPN, 2 NO/NC OUTPUT 0-10 V 0-10 V 4-10 mA 4-20 mA TERMINATION Connector Cable Connector Cable Max. sensing distance: Min. sensing distance: Switching frequency: Repeatability: OUTPUT PNP, 2 NO/NC PNP, 2 NO/NC NPN, 2 NO/NC NPN, 2 NO/NC M18/M30 Termination: ! M18 Connector Cable M12 x 1 Preleaded 2 m WARNING MISUSE OF DOCUMENTATION * The information presented in this product sheet (or catalogue) is for reference only. DO NOT USE this document as product installation information. * Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. TERMINATION Connector Cable Connector Cable Max. sensing distance: Min. sensing distance: Switching frequency: Repeatability: OUTPUT PNP, 2 NO/NC PNP, 2 NO/NC NPN, 2 NO/NC NPN, 2 NO/NC ! TERMINATION Connector Cable Connector Cable REFERENCE 943-F4V-2D-001-180E 943-F4Y-2D-001-180E 943-F4V-2D-002-180E 943-F4Y-2D-002-180E 800 mm 100 mm 4.7 Hz 0,2 % or 1 mm REFERENCE 943-F4V-2D-001-300E 943-F4Y-2D-001-300E 943-F4V-2D-002-300E 943-F4Y-2D-002-300E 500 mm 60 mm 4.7 Hz 0,2 % or 1 mm REFERENCE 943-F4V-2D-001-330E 943-F4Y-2D-001-330E 943-F4V-2D-002-330E 943-F4Y-2D-002-330E TERMINATION Connector Cable Connector Cable REFERENCE 943-F4V-2D-1C0-180E 943-F4Y-2D-1C0-180E 943-F4V-2D-1D0-180E 943-F4Y-2D-1D0-180E Max. sensing distance: Min. sensing distance: Switching frequency: Repeatability: 800 mm 100 mm 100 ms 0,2 % or 1 mm OUTPUT 0-10 V 0-10 V 4-10 mA 4-20 mA TERMINATION Connector Cable Connector Cable REFERENCE 943-F4V-2D-1C0-300E 943-F4Y-2D-1C0-300E 943-F4V-2D-1D0-300E 943-F4Y-2D-1D0-300E Max. sensing distance: Min. sensing distance: Switching frequency: Repeatability: 500 mm 60 mm 100 ms 0,2 % or 1 mm OUTPUT 0-10 V 0-10 V 4-10 mA 4-20 mA TERMINATION Connector Cable Connector Cable REFERENCE 943-F4V-2D-1C0-330E 943-F4Y-2D-1C0-330E 943-F4V-2D-1D0-330E 943-F4Y-2D-1D0-330E WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Warranty/Remedy Sales and Service Honeywell warrants goods of its manufacture as being free of defective material and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during that period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. While we provide application assistance, personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change at any time without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorised Distributor, contact your local sales office or: INTERNET: www.honeywell.com/sensing E-mail: info.sc@honeywell.com ASIA PACIFIC NORTH AMERICA EUROPE Control Products Asia Pacific Headquarters Phone: +(65) 6355-2828 FAX: +(65) 6445-3033 South Korea Honeywell Korea Co Ltd Phone: +(822) 799-6167 FAX: +(822) 792-9013 Austria Honeywell Austria GmbH Phone: +(43) 1 727 80 366/246 FAX: +(43) 1 727 80 337 Italy Honeywell S.p.A. Phone: +(39) 02 92146 450/456 FAX: +(39) 02 92146 490 Spain Honeywell S.A. Phone: +(34) 91 313 6100 FAX: +(34) 91 313 6129 Australia Honeywell Limited Phone: +(61) 2-9370-4500 FAX: +(61) 2-9370-4525 Toll Free 1300-36-39-36 Toll Free Fax: 1300-36-04-70 Malaysia Honeywell Engineering Sdn Bhd Phone: +(60-3) 7958-4988 FAX: +(60-3) 7958-8922 Belgium Honeywell SA/NV Phone: +(32) 2 728 2522 FAX: +(32) 2 728 2502 The Netherlands Honeywell B.V. Phone: +(31) 20 565 69 11 FAX: +(31) 20 565 66 00 Sweden Honeywell AB Phone: +(46) 8 775 55 00 FAX: +(46) 8 775 56 00 New Zealand Honeywell Limited Phone: +(64-9) 623-5050 FAX: +(64-9) 623-5060 Toll Free (0800) 202-088 Bulgaria Honeywell EOOD Phone: +(359) 2 979 00 23 FAX: +(359) 2 979 00 24 Norway Honeywell A/S Phone: +(47) 66 76 20 00 FAX: +(47) 66 76 20 90 Switzerland Honeywell AG Phone: +(41) 1 855 24 40 FAX: +(41) 1 855 24 45 Czech Republic Honeywell spol. s.r.o. Phone: +(420) 242 442 111 FAX: +(420) 242 442 182 Poland Honeywell Sp. zo.o Phone: +(48) 606 09 64 FAX: +(48) 606 09 01 Turkey Honeywell Turkey A.S. Phone: +(90) 216 5756620 FAX: +(90) 216 5756637 Denmark Honeywell A/S Phone: +(45) 39 55 55 55 FAX: +(45) 39 55 55 58 Portugal Honeywell Portugal Lda Phone: +(351 21) 424 50 00 FAX: +(351 21) 424 50 99 Ukraine Honeywell Phone: +(380) 44 201 44 74 FAX: +(380) 44 201 44 75 Finland Honeywell OY Phone: +(358) 9 3480101 FAX: +(358) 9 34801375 Romania Honeywell Bucharest Phone: +(40) 21 231 64 37/38 FAX: +(40) 21 231 6439 United Kingdom Honeywell Control Systems Ltd Phone: +(44) 1698 481481 FAX: +(44) 1698 481676 France Honeywell SA Phone: +(33) 1 60 19 80 40 FAX: +(33) 1 60 19 81 73 Commonwealth of Independent States (CIS) Z.A.O. Honeywell Phone: +(7 095) 796 98 36 FAX: +(7 095) 797 99 06 www.DataSheet4U.com China - PRC - Beijing Honeywell China Inc. Phone: +(86-10) 8458-3280 FAX: +(86-10) 8458-3102 China - PRC - Shanghai Honeywell China Inc. Phone: (86-21) 6237-0237 FAX: (86-21) 6237-1237 Philippines Honeywell Systems (Philippines) Inc. Phone: +(63-2) 636-1661/1662 FAX: +(63-2) 638-4013 China - Hong Kong S.A.R. Honeywell Ltd. Phone: +(852) 2953-6412 FAX: +(852) 2953-6767 Singapore Honeywell South East Asia Phone: +(65) 6355-2828 FAX: +(65) 6445-3033 Indonesia Honeywell Indonesia Pte Ltd. Phone: +(62) 21-535-8833 FAX: +(62) 21-5367 1008 Thailand Honeywell Systems (Thailand) Ltd. Phone: +(662) 693-3099 FAX: +(662) 693-3085 India TATA Honeywell Ltd. Phone: +(91) 20 6870 445/446 FAX: +(91) 20 681 2243/ 687 5992 Taiwan R.O.C. Honeywell Taiwan Ltd. Phone: +(886-2) 2245-1000 FAX: +(886-2) 2245-3241 Japan Honeywell Inc Phone: +(81) 3 5440 1425 FAX: +(81) 3 5440 1368 Germany Honeywell AG Phone: +(49) 69 8064 444 FAX: +(49) 69 8064 442 Hungary Honeywell Kft. Phone: +(361) 451 43 00 FAX: +(361) 451 43 43 Slovak Republic Honeywell s.r.o. Phone: +(421 2) 58 247 403 FAX: +(421 2) 58 247 415 South Africa (Republic of) Honeywell Southern Africa Honeywell S.A. Pty. Ltd Phone: +(27) 11 695 8000 FAX +(27) 11 805 1504 Mediterranean & African Distributors Honeywell SpA Phone: +(39) 2 921 46 232 FAX: +(39) 2 921 46 233 Middle East Headquarters Honeywell Middle East Ltd. Phone: +(9712) 443 2119 FAX +(9712) 443 2536 USA/Canada Honeywell Sensing and Control Phone: 1-800-537-6945 1-815-235-6847 FAX: 1-815-235-6545 E-mail: info.sc@honeywell.com LATIN AMERICA Honeywell Latin America Headquarters Phone: 1-305-805-8188 FAX: 1-305-883-8257 Argentina Honeywell S.A.I.C. Phone: +(54-11) 4383-3627 FAX: +(54-11) 4325-6470 Brazil Honeywell Do Brasil & Cia Phone: +(55-11) 4166-1900 FAX: +(55-11) 4166-1901 Chile Honeywell Chile, S.A. Phone: +(56-2) 425-8400 FAX: +(56-2) 425-8410 Mexico Honeywell S.A. de C.V. Phone: +(52) 55 5081-0200 FAX: +(52) 55 5081-0202 Puerto Rico, Caribbean Honeywell Inc. Phone: +(787) 792-7075 FAX: +(787) 792-0053 Venezuela Honeywell C.A. Phone: +(58-212) 273-0511 FAX: +(58-212) 273-0599 This publication does not constitute a contract between Honeywell and its customers. The contents may be changed at any time without notice. It is the customer's responsibility to ensure safe installation and operation of the products. Detailed mounting drawings of all products illustrated are available on request. Copyright 2004 Honeywell International Inc. All Rights Reserved. Sensing and Control www.honeywell.com/sensing Honeywell Control Systems Ltd Newhouse Industrial Estate Motherwell, Lanarkshire ML1 5SB Scotland, UK 100464-EN Issue 1 02/04 UK07 GLO Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 943 Series (943F4V/F4Y-2D001/002/1C0/1D0-360E) www.DataSheet4U.com Ultrasonic Distance Sensors DESCRIPTION The new 943-F4V (connector) and 943-F4Y (cable) Series industrial sensors are the latest additions to our range of ultrasonic distance sensors. They offer improved scanning ranges and remote Teach-In of the switching or analog outputs, in addition to new, advanced features, such as Window and Hysteresis modes. The devices are Teach-In compatible and have an M18 plastic housing. FEATURES * * * * POTENTIAL APPLICATIONS Non contact distance sensing for use in non invasive * Reel diameter measurement measurement * Tank level measurement Reduced sensitivity to light intensity/reflectivity/opacity of * Presence/absence of an object target for enhanced flexibility and certainty of measurement * Loop control Detects over much longer distance than other detection * Product height measurement methods reducing the need for close proximity to the target * Tire manufacturing Presence absence, tank fill level and diameter measurement provides an extremely robust and flexible measurement method * Short distance (in ultrasonic terms) for enhanced accuracy, repeatability (material independent) measurement to 30 mm [1.18 in]. * Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 943 Series (943-F4V/F4Y-2D-001/002/1C0/1D0-360E) Specifications Parameter 943-F4V-2D001-360E 943-F4V-2D002-360E 943-F4V-2D1C0-360E 943-F4V-2D943-F4Y-2D- 943-F4Y-2D1D0-360E 001-360E 002-360E 400 mm [15.75 in] 30 mm [1.18 in] 60 ms - 943-F4Y-2D1C0-360E 943-F4Y-2D1D0-360E Max. sensing distance Min. sensing distance Expected response - 60 ms time 90% of final value Beam angle 8 Switching frequency 15 Hz - 15 Hz - Linearity error - <0.5% - <0.5% Hysteresis 1% - 1% - Repeatability of 1 mm [0.039 in] 0.2% measured distance Temperature range -15 C to 70 C [-5 F to 158 F] Temperature yes compensation Operating voltage 12 Vdc to 30 Vdc 15 Vdc to 30 Vdc 12 Vdc to 30 Vdc 15 Vdc to 30 Vdc Possible min. supply - 12 Vdc - 12 Vdc Expected current <80 mA <40 mA <80 mA <40 mA www.DataSheet4U.com consumption Output 2X PNP NO/NC 2X NPN NO/NC 0 V to 10 V 4 mA to 20 mA 2X PNP NO/NC 2X NPN NO/NC 0 V to 10 V 4 mA to 20 mA Expected output 500 mA max. - 500 mA max. - current Adjustment set point Teach-In - Teach-In - Teach-In input pin 5 pink wire - Teach-In - Teach-In Sensitivity Teach-In: P1/P2 determines output position Plastic housing PBPT M18x1 Sealing* IP65 Connector M12x1 - Cable connection - 2 m [6.56 ft] *Attention! Do not expose sensor head to hot water >50 C or steam vapour. Accessories: 943-F4V-2D-001/002/1CO/1DO-360E Catalog Listing Description 66195044-001 Mating connector straight 66195045-001 Mating connector angled 66195214-001 Straight cable/connector 2 m 66195216-001 Right-angle cable/connector 2 m 43178389-018 Mounting clamp 43192871-003 Beam deflector 43192871-004 Focusing beam deflector Accessories: 943-F4Y-2D-001/002/1CO/1DO-360E Catalog Listing Description 43178389-018 Mounting clamp 43192871-003 Beam deflector 43192871-004 Focusing beam deflector 2 www.honeywell.com/sensing Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Distance Sensors Mounting Dimensions Continued (For reference only. mm/[in]) 943-F4V-2D-001/002/1C0/1D0-360E 943-F4Y-2D-001/002/1C0/1D0-360E www.DataSheet4U.com Wiring 943-F4V-2D-001-360E 943-F4V-2D-002-360E Pin 1 Pin 5 Pin 4 Pin 1 +24 Vdc R Teach-In 5 Pin 2 Switching output SP2 1 R Pin 4 Switching output SP1 Pin 2 Switching output SP2 R 2 1 Pin 5 943-F4V-2D-1C0/1D0-360E Pin 1 0V 943-F4Y-2D-001/002-360E Brown +24 V 4 Pin 4 Analogue Pin 5 Teach-In +24 Vdc 3 R R 5 1 Pin 3 2 Teach-In Pin 3 0V 3 5 R Pin 3 4 3 4 Switching output SP1 +24 Vdc Black SP1 2 Grey SP2 0 V/GND Pink Teach-In Blue 943-F4Y-2D-1C0/1D0-360E 0V Detection Range Brown +24 V Black Analogue Pink Teach-In +130 mm -130 Blue 0 V/GND 0 30 mm 400 Enhanced detection of a target 100 mm x 100 mm Possible detection of a large target Honeywell Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com WARNING WARNING PERSONAL INJURY MISUSE OF DOCUMENTATION DO NOT USE these products as safety or emergency stop * devices or in any other application where failure of the The information presented in this product sheet is for reference only. Do not use this document as a product product could result in personal injury. installation guide. Failure to comply with these instructions could result in death or serious injury. * Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of death or serious injury. defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise SALES AND SERVICE by Honeywell in writing; please refer to your order Honeywell serves its customers through a worldwide network acknowledgement or consult your local sales office for specific of sales offices, representatives and distributors. For warranty details. If warranted goods are returned to Honeywell application assistance, current specifications, pricing or name during the period of coverage, Honeywell will repair or replace, of the nearest Authorized Distributor, contact your local sales at its option, without charge those items it finds defective. The office or: warranties, expressed or implied, including those of E-mail: info.sc@honeywell.com www.DataSheet4U.com foregoing is buyer's sole remedy and is in lieu of all other merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. Internet: www.honeywell.com/sensing Phone and Fax: While we provide application assistance personally, through Asia Pacific +65 6355-2828 Europe +44 (0) 1698 481481 +65 6445-3033 Fax our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the +44 (0) 1698 481676 Fax application. Latin America +1-305-805-8188 Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Automation and Control Solutions Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, MN 61032 www.honeywell.com/sensing 004452-1-1-EN IL50 GLO Printed in USA February 2006 Copyright (c) 2006 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 943 Series (943-G4V2G-001/002-400E) Ultrasonic Distance Sensors www.DataSheet4U.com DESCRIPTION The new 943-G4V series industrial sensors are the latest addition to our range of ultrasonic distance sensors. They offer improved scanning ranges and remote Teach-In of the switching or analogue outputs, in addition to new, advanced features, such as Window and Hysteresis modes. The devices are Teach-In compatible and have an M12 stainless steel housing for the 943 G4V. FEATURES * * * * POTENTIAL APPLICATIONS Non contact distance sensing for use in non invasive * Reel diameter measurement measurement * Tank level measurement Reduced sensitivity to light intensity/reflectivity/opacity of * Presence/absence of an object target for enhanced flexibility and certainty of measurement * Loop control Detects over much longer distance than other detection * Product height measurement methods reducing the need for close proximity to the target * Tire manufacturing Short distance (in ultrasonic terms) for accuracy, repeatability (material independent) measurement to 25 mm [0.98 in]. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 943 Series (943-G4V-2G-001/002-400E) Specifications Parameter 943-G4V-2G-001-400E 943-G4V-2G-002-400E Max. sensing distance 250 mm [9.84 in] Min. sensing distance 25 mm [0.98 in] Switching frequency 30 Hz Hysteresis 1% Beam angle 8 Repeatability 0,3 mm [0.012 in] Temperature range -20 C to 70 C [-4 F to 158 F] Operating voltage 10 Vdc to 30 Vdc Expected current consumption <100 mA Output PNP NO/NC NPN NO/NC Expected output current 100 mA max. www.DataSheet4U.com Adjustment set point Teach-In Stainless steel housing M12x1 Sealing* IP65 Connector M12x1 *Attention! Do not expose sensor head to hot water >50 C or water vapour. Accessories Catalog Listing 66195044-001 66195045-001 Description Mating connector straight Mating connector angled Mounting Dimensions (For reference only. mm/[in]) 2 www.honeywell.com/sensing Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Distance Sensors Wiring Pin 1 +24 V R Pin 4 Pin 2 www.DataSheet4U.com Teach-In Pin 3 4 3 1 2 0V Detection Range +15 mm - 15 0 25 mm 200 Enhanced detection of a target 100 mm x 100 mm Possible detection of a large target Honeywell Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com WARNING WARNING PERSONAL INJURY MISUSE OF DOCUMENTATION DO NOT USE these products as safety or emergency stop * devices or in any other application where failure of the The information presented in this product sheet is for reference only. Do not use this document as a product product could result in personal injury. installation guide. Failure to comply with these instructions could result in death or serious injury. * Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of death or serious injury. defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise SALES AND SERVICE by Honeywell in writing; please refer to your order Honeywell serves its customers through a worldwide network acknowledgement or consult your local sales office for specific of sales offices, representatives and distributors. For warranty details. If warranted goods are returned to Honeywell application assistance, current specifications, pricing or name during the period of coverage, Honeywell will repair or replace, of the nearest Authorized Distributor, contact your local sales at its option, without charge those items it finds defective. The office or: warranties, expressed or implied, including those of E-mail: info.sc@honeywell.com www.DataSheet4U.com foregoing is buyer's sole remedy and is in lieu of all other merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. Internet: www.honeywell.com/sensing Phone and Fax: While we provide application assistance personally, through Asia Pacific +65 6355-2828 Europe +44 (0) 1698 481481 +65 6445-3033 Fax our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the +44 (0) 1698 481676 Fax application. Latin America +1-305-805-8188 Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Automation and Control Solutions Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, MN 55422 www.honeywell.com/sensing 004449-1-EN IL50 GLO Printed in USA February 2006 Copyright (c) 2006 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 943 Series (943-K4U2G-001/002/1C0-400E) Ultrasonic Distance Sensors www.DataSheet4U.com DESCRIPTION The new 943-K4U series industrial sensors are the latest addition to our range of ultrasonic distance sensors. They offer improved scanning ranges and remote Teach-In of the switching or analogue outputs, in addition to new, advanced features, such as Window and Hysteresis modes. The devices are Teach-In compatible and have a plastic housing. FEATURES * * * * POTENTIAL APPLICATIONS Non contact distance sensing for use in non invasive * Level measurement in small containers/test tubes measurement * Small object detection in narrow environments Reduced sensitivity to light intensity/reflectivity/opacity of * Presence detection target for enhanced flexibility and certainty of measurement * Winding/unwinding control Detects over much longer distance than other detection * Height/thickness measurement methods reducing the need for close proximity to the target * Parts counting Presence absence, tank fill level and diameter measurement provide an extremely robust and flexible measurement method * Miniature form factor device fits into the smallest mounting positions * Two mounting methods provide flexibility of mounting options to suit the application Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 943 Series (943-K4U-2G-001/002/1C0-400E) Specifications Parameter Max. sensing distance Min. sensing distance Switching frequency Linearity error Hysteresis Repeatability of measured distance 943-K4U-2G-001-400E 943-K4U-2G-002-400E 250 mm [9.84 in] 25 mm [0.98 in] 25 Hz - 2% - 943-K4U-2G-1C0-400E - <0.3% - 0.2 mm [0.008 in] 0.2% Beam angle 8 Temperature range -25 C to 70 C [-13 F to 158 F] Temperature compensation yes Operating voltage 10 Vdc to 30 Vdc 12 Vdc to 30 Vdc www.DataSheet4U.com Expected current consumption <100 mA Output PNP NO/NC NPN NO/NC 0 V to 10 V Expected output current 100 mA max. - Adjustment set point Teach-In - Adjustment - Teach-In Housing material plastic Sealing* IP67 Connector M8 *Attention! Do not expose sensor head to hot water >50 C or steam vapour. Mounting Dimensions (For reference only. mm/[in]) 2 www.honeywell.com/sensing Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Distance Sensors Wiring 943-K4U-2G-001-400E Pin 1 943-K4U-2G-002-400E Pin 1 +24 V 2 4 R 3 1 Pin 2 Teach-In Pin 4 Switching output 0V Pin 1 Pin 2 Teach-In Pin 3 0V +24 V 2 4 1 Pin 4 R Pin 3 943-K4U-2G-1C0-400E +24 V 3 R 2 4 1 Pin 4 Pin 2 Teach-In Pin 3 0V 3 Detection Range www.DataSheet4U.com +15 mm - 15 0 25 mm 250 Enhanced detection of a target 100 mm x 100 mm Possible detection of a large target Honeywell Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com WARNING WARNING PERSONAL INJURY MISUSE OF DOCUMENTATION DO NOT USE these products as safety or emergency stop * devices or in any other application where failure of the The information presented in this product sheet is for reference only. Do not use this document as a product product could result in personal injury. installation guide. Failure to comply with these instructions could result in death or serious injury. * Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of death or serious injury. defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise SALES AND SERVICE by Honeywell in writing; please refer to your order Honeywell serves its customers through a worldwide network acknowledgement or consult your local sales office for specific of sales offices, representatives and distributors. For warranty details. If warranted goods are returned to Honeywell application assistance, current specifications, pricing or name during the period of coverage, Honeywell will repair or replace, of the nearest Authorized Distributor, contact your local sales at its option, without charge those items it finds defective. The office or: warranties, expressed or implied, including those of E-mail: info.sc@honeywell.com www.DataSheet4U.com foregoing is buyer's sole remedy and is in lieu of all other merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. Internet: www.honeywell.com/sensing Phone and Fax: While we provide application assistance personally, through Asia Pacific +65 6355-2828 Europe +44 (0) 1698 481481 +65 6445-3033 Fax our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the +44 (0) 1698 481676 Fax application. Latin America +1-305-805-8188 Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Automation and Control Solutions Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, MN 55422 www.honeywell.com/sensing 004450-1-EN IL50 GLO Printed in USA February 2006 Copyright (c) 2006 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 948 Series (948-ISY2D-001/002/003/004180E) www.DataSheet4U.com Ultrasonic Distance Sensors DESCRIPTION The 948 Series is one of the smallest ultrasonic scan through devices in the world. Its small, rectangular, IP67-rated plastic housing makes it easy to install in limited space applications. The sensor consists of two parts, a transmitter and a receiver. It is especially suited for food and beverage applications, in particular bottle counting. FEATURES * * POTENTIAL APPLICATIONS Thru-scan detection regardless of the object material for * Food and beverage machinery and equipment enhanced detection * Rapid presence/absence detection: bottle counting Non contact distance sensing for use in non invasive * Loop control measurement * Reduced sensitivity to light intensity/reflectivity/opacity of target for enhanced flexibility and certainty of measurement * Detects over much longer distance than other detection methods reducing the need for close proximity to the target * Presence absence, tank fill level and diameter measurement provides an extremely robust and flexible measurement method Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 948 Series (948-ISY-2D-001/002/003/004-180E) Specifications Parameter Sensing distance Response time on/off Beam angle Output Expected output current Switching frequency Temperature range Operating voltage Expected current consumption Housing Sealing Cable connection 948-ISY-2D-001-180E NO PNP 948-ISY-2D-002-180E 948-ISY-2D-003-180E 1100 mm [3.61 ft] 3 ms 15 NO NPN NC PNP 500 mA 150 Hz -15 C to 60 C [-5 F to140 F] 18 Vdc to 30 Vdc <40 mA 948-ISY-2D-004-180E NC NPN plastic IP67 2 m [6.56 ft] Sensor consists of 2 parts: 1 transmitter and 1 receiver. www.DataSheet4U.com With flat targets best results may be achieved with an angle 30 object-ultrasonic beam. 2 www.honeywell.com/sensing Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Ultrasonic Distance Sensors Mounting Dimensions (For reference only. mm/[in]) Transmitter Brown: Vdc Blue: 0 V Receiver www.DataSheet4U.com Brown: Vdc Blue: 0 V Black: O/P Honeywell Sensing and Control 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com WARNING WARNING PERSONAL INJURY MISUSE OF DOCUMENTATION DO NOT USE these products as safety or emergency stop * devices or in any other application where failure of the The information presented in this product sheet is for reference only. Do not use this document as a product product could result in personal injury. installation guide. Failure to comply with these instructions could result in death or serious injury. * Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of death or serious injury. defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise SALES AND SERVICE by Honeywell in writing; please refer to your order Honeywell serves its customers through a worldwide network acknowledgement or consult your local sales office for specific of sales offices, representatives and distributors. For warranty details. If warranted goods are returned to Honeywell application assistance, current specifications, pricing or name during the period of coverage, Honeywell will repair or replace, of the nearest Authorized Distributor, contact your local sales at its option, without charge those items it finds defective. The office or: warranties, expressed or implied, including those of E-mail: info.sc@honeywell.com www.DataSheet4U.com foregoing is buyer's sole remedy and is in lieu of all other merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. Internet: www.honeywell.com/sensing Phone and Fax: While we provide application assistance personally, through Asia Pacific +65 6355-2828 Europe +44 (0) 1698 481481 +65 6445-3033 Fax our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the +44 (0) 1698 481676 Fax application. Latin America +1-305-805-8188 Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Automation and Control Solutions Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, MN 55422 www.honeywell.com/sensing 004448-1-EN IL50 GLO Printed in USA February 2006 Copyright (c) 2006 Honeywell International Inc. All rights reserved. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com