Ultrasonic Sensors 940 Series
Compact 18 mm Diameter Digital
B82 Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada
FEATURES
1Sensing distance up to 1,5 meters
118 mm diameter housing
1IP 67 sealing
1High output current
1High power transducer
1Microprocessor controlled
ORDER GUIDE
Sensor Sensing Digital
Package Range* Output Termination Catalog
Style mm (in.) Listing
18 mm dia. 200 - 1500 PNP, N.O. Cable 940-F4Y-2D-001-180E
PBTB Plastic (7.87 - 59.05) NPN, N.O. Cable 940-F4Y-2D-002-180E
PNP, N.O. Connector cable 940-F4X-2D-001-180E
NPN, N.O. Connector cable 940-F4X-2D-002-180E
150 - 700 PNP, N.O. Cable 940-F4Y-2D-001-300E
(5.9 - 27.5) NPN, N.O. Cable 940-F4Y-2D-002-300E
PNP, N.O. Connector cable 940-F4X-2D-001-300E
NPN, N.O. Connector cable 940-F4X-2D-002-300E
* Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam.
SPECIFICATIONS
Catalog Listings 940-F4Y-2D-001-180E 940-F4Y-2D-001-300E
940-F4Y-2D-002-180E 940-F4Y-2D-002-300E
940-F4X-2D-001-180E 940-F4X-2D-001-300E
940-F4X-2D-002-180E 940-F4X-2D-002-300E
Max. Sensing Distance 1500 mm (59.05 in.) 700 mm (27.5 in.)
Min. Sensing Distance 200 mm (7.87 in.) 150 mm (5.91 in.)
Beam Angle 8°8°
POWER SUPPLY
Supply Voltage 19 - 30 VDC
Supply Current <25 mA without load <35 mA without load
Circuit Protection Reverse polarity
OUTPUT CHARACTERISTICS
Load Current 0 - 500 mA
Switching Frequency 8 Hz 25 Hz
Hysteresis `2% of setpoint `2.5% of setpoint
Repeatability ±1 mm
Setpoint Adjustment 4-turn potentiometer
Circuit Protection Short circuit
ENVIRONMENTAL
Operating Temperature 15 to 70°C (5 to 158°F)
Storage Temperature 25 to 85°C (–13 to 185°F)
Sealing IP 67
SPECIAL FEATURES
Hold Input Stops transmission and reception when input is connected to 0 VDC. Last output will be stored until input is disconnected
Synchronization Input Avoids mutual interference from several sensors by interconnecting the hold input from each sensor.
LED Indicator Illuminates when sensor detects target
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Sensors 940 Series
Compact 18 mm Diameter Digital
Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada B83
WIRING DIAGRAM
*Normal operation with no connection
MOUNTING DIMENSIONS (For reference only)
940-F4X/Y-20-001/2-180E
940-F4X/Y-20-001/2-300E Versions only
940-F4X/Y-2D-001/2-300E
4-pin DC Micro
(M12 x 1)
Pin Color
1 BRN
2 PINK
3 BLU
4 BLK
ACCESSORIES
Catalog Listing Feature
Mounting clamp 43178389-018 Allows mounting to a flat surface
Beam deflector 43192871-003 Allows right angle mounting (Approx. dim. 50 x 170 mm)
Focusing beam deflector 43192871-004 Reduces beam angle by approximately 1/2 (Approx. dim.
35 x 52 mm)
Straight connector w/o cable 66195044-001 Connector has screw terminals for wiring connection
Right angle connector w/o cable 66195045-001 Connector has screw terminals for wiring connection
24 VDC Power supply, Relay output, 110 VAC input FF-MADB24RB See page B102 for more information
24 VDC POwer supply, On/Off delay, 110 VAC input FF-MADC24RB See page B102 for more information
Proximity
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Sensors 940 Series
30 mm Diameter Analog
B84 Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada
FEATURES
1Measuring range up to 2000 mm (78.74
in.)
1High repeatability
ORDER GUIDE
Sensor Sensing
Package Range* Analog Termi- Catalog
Style mm (in.) Output nation Listing
30 mm dia. 300 - 2000 1.5 - 10 V Cable 940-A4Y-AD-1C0-130E
Stainless Steel (11.81 - 78.74)
150 - 1200 1.25 - 10 V Cable 940-A4Y-AD-1C0
(5.90 - 47.24) Connector 940-A4V-AD-1C0
* Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam.
SPECIFICATIONS
Catalog Listings 940-A4Y-AD-1C0
940-A4Y-AD-1C0-130E 940-A4V-AD-1C0
Max. Range Max. Rate Max. Range Max. Rate
Max. Sensing Distance 2000 mm (78.74 in.) 1000 mm (39.37 in.) 1200 mm (47.2 in.) 600 mm (23.6 in.)
Min. Sensing Distance 300 mm (11.8 in.) 150 mm (5.91 in.)
Beam Angle 8°10°
POWER SUPPLY
Supply Voltage 19 - 30 VDC
Supply Current <20 mA without load
Circuit Protection Reverse polarity
OUTPUT CHARACTERISTICS
Load Current 10 mA max.
Switching Frequency 6 Hz 11 Hz
Repeatability ±2 mm ±1 mm
Linearity <0.2%
Output Adjustment 4 Turn Potentiometer
Output Mode Max. Range or Max. Rate selected by wiring terminal connection
Circuit Protection Short Circuit
ENVIRONMENTAL
Operating Temperature 0 to 50°C (32 to 122°F)
Storage Temperature 0 to 70°C (32 to 158°F)
Sealing IP 65
SPECIAL FEATURES
Hold Input Stops transmission and reception of sensor when input is connected to 0 VDC. Analog output would be zero.
Synchronization Input Avoids mutual interference from several ultrasonic sensors (external synchronization unit required; see Accessories)
LED Indicator Illuminates when sensor detects a target
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Sensors 940 Series
30 mm Diameter Analog
Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada B85
WIRING DIAGRAM
*Normal operation with connection +19-30 VDC
CONNECTOR VERSION
ONLY
Pin Color
1 BRN
2 WHT
3 BLU
4 BLK
5 GRAY
MOUNTING DIMENSIONS (For reference only)
940-A4V-AD-1C0
940-A4Y-AD-1C0-130E
940-A4Y-AD-1C0
ACCESSORIES
Catalog Listing Feature
Mounting clamp, 30 mm sensor 43178389-030 Allows mounting to a flat surface
Beam deflector 43192871-001 Allows right angle mounting (Approx. dim. 50 x 170 mm)
Focusing beam deflector 43192871-002 Reduces beam angle by approximately 1/2
Compact deflector 66195116-001 Allows right angle mounting (Approx. dim. 35 x 52 mm)
2 meter cable, Straight connector RKT5-612/2M Used for wiring to connector version
5 meter cable, Straight connector RKT5-612/5M Used for wiring to connector version
2 meter cable, Right angle connector RKWT5-612/2M Used for wiring to connector version
5 meter cable, Right angle connector RKWT5-612/5M Used for wiring to connector version
Synchronization unit 55000001 Controls up to 100 sensors
Proximity
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Sensors 942 Series
Compact 30 mm Diameter Analog and Digital, RS232/RS485 Interface
B86 Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada
FEATURES
1Programmable
1RS232 or RS485 interface
10 - 10 VDC/4 - 20 mA output
1Two N.O. PNP outputs or one N.O.
PNP/one N.C. PNP output
ORDER GUIDE
Sensor Sensing
Package Range* Analog Digital Catalog
Style mm (in.) Output Output Interface Listing
30 mm dia. 300 - 3000 0 - 10 V PNP, N.O./N.C. RS232 942-A4N-2D-1C1-130E
Stainless Steel (11.8 - 118) 4 - 20 mA PNP, N.O./N.C. RS232 942-A4N-2D-1D1-130E
0 - 10 V PNP, N.O./N.C. RS485 942-A4N-2D-1E1-130E
4 - 20 mA PNP, N.O./N.C. RS485 942-A4N-2D-1F1-130E
150 - 1500 0 - 10 V PNP, N.O./N.C. RS232 942-A4N-2D-1C1-220S
(5.9 - 59.1) 4 - 20 mA PNP, N.O./N.C. RS232 942-A4N-2D-1D1-220S
0 - 10 V PNP, N.O./N.C. RS485 942-A4N-2D-1E1-220S
4 - 20 mA PNP, N.O./N.C. RS485 942-A4N-2D-1F1-220S
100 - 600 0 - 10 V PNP, N.O./N.C. RS232 942-A4N-2D-1C1-300E
(3.94 - 23.6)
272,1g (9.6 oz)
* Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam.
SPECIFICATIONS
Catalog Listings 942-A4N-2D-1C1-130E 942-A4N-2D-1C1-220S
942-A4N-2D-1D1-130E 942-A4N-2D-1D1-220S
942-A4N-2D-1E1-130E 942-A4N-2D-1E1-220S
942-A4N-2D-1F1-130E 942-A4N-2D-1F1-220S 942-A4N-2D-1C1-300E
Max. Sensing Distance 3000 mm (118 in.) 1500 mm (59.1 in.) 600 mm (23.6 in.)
Min. Sensing Distance 300 mm (11.8 in.) 150 mm (5.91 in.) 100 mm (3.94 in.)
Beam Angle 8°10°8°
POWER SUPPLY
Supply Voltage 19 - 30 VDC
Supply Current <30 mA without load
Circuit Protection Reverse Polarity
OUTPUT CHARACTERISTICS (DIGITAL)
Load Current 0 - 100 mA
Hysteresis Programmable (0 - 255 mm)
Switching Frequency Programmable 5-30 Hz Programmable 5-30 Hz Programmable 5-50 Hz
Repeatability ±2 mm or ±0.4% of reading
Setpoint Adjust Programmable within sensing range
Circuit Protection Short circuit
OUTPUT CHARACTERISTICS (ANALOG)
Switching Frequency Programmable 5-30 Hz Programmable 5-30 Hz Programmable 5-50 Hz
Repeatability ±2 mm or ±0.4% of reading
Linearity 3 mm or ±0.5%
Output Adjust Programmable
Circuit Protection Short circuit
ENVIRONMENTAL
Operating Temperature 15 to 70°C (5 to 150°F
Storage Temperature 25 to 85°C (–13 to 185°F)
Sealing IP 65
SPECIAL FEATURES
Hold Input Stops transmission and reception when input is connected to 0 VDC. Analog output would be zero.
Synchronization input Avoids mutual interference from several sensors by interconnecting the Hold input from each sensor.
LED Indicator Illuminates when sensor detects target
Programmable Parameters Analog Output: Span, Offset, Positive or Negative slope
Digital Output: Hysteresis, N.O./N.C.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Sensors 942 Series
Compact 30 mm Diameter Analog and Digital, RS232/RS485 Interface
Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada B87
WIRING DIAGRAM
*Normal operation with no connection
MOUNTING DIMENSIONS (For reference only)
ACCESSORIES
Catalog Listing Features
Mounting clamp 43178389-030 Allows mounting to flat surface
Beam deflector 43192871-001 Allows right angle mounting (approx. dim. 50 x 170 mm)
Focusing beam deflector 43192871-002 Reduces beam angle by approximately 50%
Compact deflector 66195116-001 Allows right angle mounting (approx. dim. 35 x 52 mm)
Programming adapter 55000005-002 Allows sensor programming via RS232 interface
RS232/RS485 converter 55000003-001 Converts RS232 interface to RS485 interface
24 VDC Power supply, relay output, 110 VAC input FF-MADB24RB See page B102 more information
24 VDC Power supply, On/Off delay, 110 VAC input FF-MADC24RB See page B102 more information
Software package (disk, manual, cable +1 sub min D9
connector) 55195101-101 Allows programming of sensor
Software package (disk, manual, cable +2 sub min D9
connectors) 55195101-102 Allows programming of sensor
Straight connector 66195126-001 Used for wiring to connector
2 meter cable with straight connector 55195126-001 Used for wiring to connector
Proximity
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Sensors 942 Series
2-Piece 30 mm Diameter
Precision Switching, Analog, Digital BCD, Hexadecimal Outputs
B88 Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada
FEATURES
1Background suppression
1Sensor sealed to IP 65
1Amplifier sealed to IP 54
1DIN rail mounting
1Compensated over 0 to 50°C
(32 to 120°F)
1Amplifier provides analog, digital
switching, BCD or hexadecimal outputs
ORDER GUIDE
Sensor Sensing Multiplex
Package Range* Digital Digital Analog Catalog
Style mm (in.) Output** Output Output Listing***
30 mm (1.18 in.) 150 - 1500 Two PNP BCD/HEX 0 - 10 VDC 942-M3A-2D-1G1-220S
Stainless steel sensor head (5.9 - 59.0) N.O. or N.C. 4 - 20 mA
*Standard target: 120 mm thick
square of mild steel perpendicular to
ultrasonic beam.
**N.O./N.C. output selectable
***Includes stainless steel sensor
head, cable, straight connector and
amplifier.
272g (9.6 oz)
SPECIFICATIONS
Max. Sensing Distance 1500 mm (59.1 in.)
Min. Sensing Distance 150 mm (5.91 in.)
Beam Angle 10°/5°
POWER SUPPLY
Supply Voltage 19-30 VDC
Supply Current <130 mA without load
Circuit Protection Reverse polarity
OUTPUT CHARACTERISTICS (DIGITAL)
Load Current 0-100 mA
Hysteresis ±1% of setpoint
Switching Frequency 8 Hz
Repeatability ±1 mm or 0.2% of reading
Setpoint Adjustment Digital switches
Output Adjustment Beam angle 10°w/max. sensitivity or beam angle 5°w/min. sensitivity
Circuit Protection Short circuit
OUTPUT CHRACTERISTICS (MULTIPLEX DIGITAL)
Resolution 1 mm
Information Output Bit Parallel/Word Serial
Setpoint Adjustment Beam angle 10°w/max. sensitivity or beam angle 5°w/min. sensitivity
OUTPUT CHARACTERISTICS (ANALOG)
Switching Frequency 8 Hz
Repeatability ±1 mm or 0.2% of reading
Linearity ±2 mm or 0.3%
Output Range Adjustment Digital switches
Output Adjustment Beam angle 10°w/max. sensitivity or beam angle 5°w/min. sensitivity
Min. Load Resistance (VDC) 1000 Ohms (0-10 VDC output)
Max. Load Resistance (mA) 250 Ohms (4-20 mA output)
Slope of Output Positive or Negative via switch
ENVIRONMENTAL
Operating Temperature Sensor head: 0 to 70°C (32 to 158°F)/Amplifier: 0 to 50°C (32 to 122°F)
Storage Temperature Sensor head/Amplifier: –25 to 85°C (– 13 to 185°F)
Sealing Sensor Head: IP 65/Amplifier: IP 54
SPECIAL FEATURES
LED Indicators RED - Under Range/ RED - Over Range: illumination dependent on analog range chosen and target
position with respect to sensor
YELLOW - Setpoint: illuminates when target reaches setpoint 1 or setpoint 2
Hold Input Stops transmission and reception when input is connected to 0 VDC. Last output stored until input is disconnected
Synchronization Input Avoids mutual interference from several sensors by interconnecting the hold input from each sensor
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Sensors 942 Series
2-Piece 30 mm Diameter
Precision Switching, Analog, Digital BCD, Hexadecimal Outputs
Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada B89
WIRING DIAGRAM MOUNTING DIMENSIONS (For reference only)PWS External supply terminals
1 19-30 V 19-30 V supply
2 GND 0 V line
Sensor head Sensor head terminals
3 19-30 V +Vs supply voltage
4 GND 0 V line
5 STA Signal transmit
command
6 STO Stop signal, echo
received
7 SEN Receive sensitivity
8 TEM Temperature sensor
RM CO Transmit control
9 GND 0 V line
10 HLD Transmit inhibit,
synchronize
Outputs Switching outputs
11 GND 0 V line
12 ORA No echo, out of range
13 URA Under range, target too
close
14 SP1 Switching output 1
15 SP2 Switching output 2
Analog out Analog outputs
16 V V out, 0-10 V
17 GND 0 V line
18 I Current out, 4-20 mA
Digital out Multiplexed digital
outputs
23 1031000 decade strobe
24 102100 decade strobe
25 10110 decade strobe
26 1001 decade strobe
27 238 BCD/HEX
28 224 BCD/HEX
29 212 BCD/HEX
30 201 BCD/HEX
ACCESSORIES
Catalog Listing Features
Mounting clamp 43178389-030 Allows mounting to flat surface
Beam deflector 43192871-001 Allows right angle mounting (approx. dim. 50 x 170 mm)
Focusing beam deflector 43192871-002 Reduces beam angle by approximately 50%
Compact deflector 66195116-001 Allows right angle mounting (approx. dim. 35 x 52 mm)
REPLACEMENT LISTINGS
Sensor Head 942A4M-2D-K220S
Amplifier 942-M0A-2D-1G1-220S
Straight Connector (cable not included) 66195074-001
942 SERIES ULTRASONIC CROSS REFERENCE
Obsolete Listing Replacement Listing Comments
942-M88 942-M96 Sensor head, includes
942-M88-LF connector
942-M3A-2D-1G1 942-M0A-2D-1G1-220S Amplifier
Proximity
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Temperature Sensors HRTS Series
Platinum RTDs
Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada
93
FEATURES
1Resistance interchangeable
1Accurate
1Linear
1Fast
1Laser trimmed
1Bolt, cement-on or strap-on models
TYPICAL APPLICATIONS
1HVAC – room, duct and refrigerant
equipment
1OEM assemblies
1Electronic assemblies –
semiconductor protection,
temperature compensation
1Process control – temperature
regulation
The HRTS is designed to measure sur-
face temperatures from 200°to +480°C
(320°to +900°F) in printed circuit, tem-
perature probe, or other applications.
HRTS surface temperature sensors are
fully assembled elements, ready to use,
without the need for fragile splices to ex-
tension leads.
A thin layer of platinum is deposited on an
alumina substrate and laser trimmed to a
resistance interchangeability of ±0.2%
with ±0.5°C accuracy or ±0.1% with
±0.3°C accuracy. The sensor chip is then
glassed, wired and potted or ceramic
fired to result in a cylindrical alumina
package with either Teflon or fiber glass
insulated lead wires.
ORDER GUIDE
HRTS-5760-B Miniature, ceramic body, 28 ga TFE Teflon insulated leads (2-wire only)
HRTS-61 Bolt-on, nickel plated copper alloy body, 24 ga fiberglass insulated leads,
SST braid, TFE overwrap, spiral armor
-T 100V, 0.00385 V/V/°C, 3-wire leads, DIN specification
-U 1000V, 0.00375 V/V/°C, 2-wire leads
-0 ±0.2% Resistance Trim (Standard)
-1 ±0.1% Resistance Trim (Optional)
-12 Standard length, HRTS-5760-B
-24 Standard length, HRTS-61
MOUNTING DIMENSIONS (for reference only)
HRTS-5760-B
HRTS-61
Fig. 1: Wheatstone Bridge 2-Wire
Interface
Fig. 2: Linear Output Voltage
Fig. 3: Adjustable Point (Comparator)
Interface
Temperature
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Temperature Sensors HRTS Series
Platinum RTDs
94
Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada
FUNCTIONAL BEHAVIOR
RTJR0(1+AT+BT2100CT3+CT4)
RT JResistance (V) at temperature T (°C)
R0JResistance (V) at 0°C
T JTemperature in °C
A Ja+ad B Jad C
T<0Jab
100 10021004
CONSTANTS
Alpha, a(°C-1) 0.00375 0.003850
±0.000029 ±0.000010
Delta, d(°C) 1.605 ±0.009 1.4999 ±0.007
Beta, b(°C) 0.16 0.10863
A (°C-1) 3.81×10-3 3.908×10-3
B (°C-2)6.02×10-7 5.775×10-7
C (°C-4)6.0×10-12 4.183×10-12
Both bJ0 and C J0 for T>0°C
RESISTANCE VS TEMPERATURE CURVE
ACCURACY VS TEMPERATURE
HRTS platinum RTDs are available in two base resistance trim
tolerances: ±0.2% or ±0.1%. The corresponding resistance
interchangeability and temperature accuracy for these toler-
ances are:
Tolerance Standard ±0.2% Optional ±0.1%
Temperature ±DR* ±DT±DR* ±DT
(°C) (V)(°C) (V)(°C)
200 6.8 1.6 5.1 1.2
100 2.9 0.8 2.4 0.6
0 2.0 0.5 1.0 0.3
100 2.9 0.8 2.2 0.6
200 5.6 1.6 4.3 1.2
300 8.2 2.4 6.2 1.8
400 11.0 3.2 8.3 2.5
500 12.5 4.0 9.6 3.0
600 15.1 4.8 10.4 3.3
*1000VRTD. Divide DR by 10 for 100VRTD.
CAUTION
PRODUCT DAMAGE
The inherent design of this component causes it to be sensitive
to electrostatic discharge (ESD). To prevent ESD-induced
damage and/or degradation, take normal ESD precautions
when handling this product.
SPECIFICATIONS
Sensor Type Thin film platinum RTD:
RoJ1000 V@0°C; alpha J0.00375 V/V/°C
RoJ100 V@0°C; alpha J0.00385 V/V/°C
Temperature Range HRTS-5760-B: 200°to +260°C (320°to +500°F)
HRTS-61: 75°to +425°C (100°to +800°F)
Temperature Accuracy ±0.5°C or 0.8% of temperature @ 0.2% RoTrim
±0.3°C or 0.6% of temperature @ 0.1% RoTrim Optional
Time Constant, 1/e HRTS-5760-B: Typically 0.6 sec. on metal surfaces
HRTS-61: Typically 20 sec. On metal surfaces
Operating Current 2 mA max. for self-heating errors of 1°C
1 mA recommended
Self-Heating 0.3 mW/°C
Lead Material Nickel coated stranded copper, Teflon or Fiberglass insulated
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Sensors 945 Series
Precision Digital 18 mm Diameter
B90 Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada
FEATURES
1Background suppression
1Sealed to IP 65
1Fixed or adjustable setpoint control
1Temperature compensation over 0 to
50°C (32 to 122°F)
1Inhibit/synchronization input
1Stainless steel or plastic housings
ORDER GUIDE
Sensor Sensing
Package Range* Output Catalog
Style mm (in.) Setpoint Type Listing
18 mm dia. 100 - 500 Fixed @ 400 mm (15.75 in.) ±20 mm** PNP, N.O. 945-F4Y-AD-001
Plastic (3.9 - 19.68) NPN, N.O. 945-F4Y-AD-002
100 - 200 Fixed @ 200 mm (7.87 in.) ±20 mm** PNP, N.O. 945-N4Y-AD-001
(3.9 - 7.87) NPN, N.O. 945-N4Y-AD-002
200 - 500 Setpoint adjustment within sensing range PNP, N.O. 945-F4Y-AD-001-180E
(7.87 - 19.68)
70 - 180 Setpoint adjustment within sensing range PNP, N.O. 945-F4Y-AD-001-300E
(2.76 - 7.09)
90,7 g (3.2 oz.)
18 mm dia. 100 - 500 Setpoint adjustment within sensing range PNP, N.O. 945-L4Y-AD-001
Stainless Steel (3.9 - 19.68) NPN, N.O. 945-L4Y-AD-002
100 - 200 Setpoint adjustment within sensing range PNP, N.O. 945-S4Y-AD-001
(3.9 - 7.87) NPN, N.O. 945-S4Y-AD-002
136 g (4.8 oz.)
* Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam.
**External setpoint adjustment wiring possible.
SPECIFICATIONS
SENSING CHARACTERISTICS
Catalog Listings 945-F4Y-AD-001 945-N4Y-AD-001 945-F4Y-AD-001-180E 945-F4Y-AD-001-300E
945-F4Y-AD-002 945-N4Y-AD-002
945-L4Y-AD-001 945-S4Y-AD-001
945-L4Y-AD-002 945-S4Y-AD-002
Max. Sensing Distance 500 mm (19.66 in.) 200 mm (7.87 in.) 500 mm (19.66 in.) 180 mm (7.09 in.)
Min. Sensing Distance 100 mm (3.9 in.) 100 mm (3.9 in.) 200 mm (7.87 in.) 70 mm (2.76 in.)
Beam Angle 10°10°8°8°
POWER SUPPLY
Supply Voltage 19 - 30 VDC
Supply Current <30 mA without load <25 mA without load
Circuit Protection Reverse polarity
OUTPUT CHARACTERISTICS
Load Current 0 - 100 mA
Hysteresis `10 mm
Switching Frequency 30 Hz 60 Hz 25 Hz 60 Hz
Repeatability ±0.5 mm or 0.3% or reading ±0.2 mm or 0.2% or reading
Setpoint Adjustment (Fixed or External Circuit) or 4 Turn Potentiometer
Circuit Protection Short Circuit
ENVIRONMENTAL
Operating Temperature 0 to 50°C (32 to 122°F)
Storage Temperature 0 to 70°C (32 to 150°F)
Sealing IP 65
SPECIAL FEATURES
Hold Input Stops transmission and reception when input is connected to 0 VDC. Last output will be stored until input is disconnected
Synchronization Input Avoids mutual interference from several sensors. (External synchronization unit is required. See Accessories)
LED Indicator Illuminates when sensor detects target
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Sensors 945 Series
Precision Digital 18 mm Diameter
Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada B91
WIRING DIAGRAMS
945-F/N Series
*Normal operation with no connection
MOUNTING DIMENSIONS (For reference only)
945-F/N Series plastic Housing
945-L/S Series
*Normal operation with no connection
945-L/S Series Stainless Steel Housing
ACCESSORIES
Catalog Listing Features
24 VDC Power supply, relay output, 110 VAC input FF-MADB24RB See page B102 for more information
24 VDC Power supply, ON/OFF delay, 110 VAC input FF-MADC24RB See page B102 for more information
Synchronization unit 55000001 Controls up to 100 sensors
Mounting clamp, 18 mm housing 43178389-018 Allows mounting to a flat surface
Beam deflector 43192871-003 Allows right angle mounting (approx. dim. 50 x 170 mm)
Focusing beam deflector 43192871-004 Reduces beam angle by approximately 50%
Proximity
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Sensors 945 Series
Precision Analog 18 mm Diameter
B92 Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada
FEATURES
1Background suppression
1Sealed to IP 65
1Adjustable sensitivity
1Temperature compensation over 0 to
50°C (32 to 122°F)
1Inhibit/synchronization input
1Stainless steel or plastic housings
ORDER GUIDE
Sensor Sensing
Package Range* Analog Catalog
Style mm (in.) Output Listing
18 mm dia. 150 - 600 1.5 - 6 V 945-F4Y-AD-1C0-180E
Plastic (5.9 - 23.6)
60 - 200 1.8 - 6 V 945-F4Y-AD-1C0-300E
(2.36 - 7.87)
90,7 g (3.2 oz.)
18 mm dia. 100 - 600 1 - 6 V 945-L4Y-AD-1C0
Stainless Steel (3.9 - 23.6)
136 g (4.8 oz.)
18 mm dia. Plastic with 150 - 600 1.5 - 6 V 945-E3Y-AD-1C0-180E
Stainless Steel or Plastic External (5.9 - 23.6) (M18 x 1 stainless steel sensor
head)
Head 30 - 150 0.9 - 4.5 V 945-G3Y-AD-1C0-300E
(1.18 - 5.9) (M12 x 1 plastic sensor head)
SPECIFICATIONS
Catalog Listings 945-F4Y-AD-1C0-180E 945-F4Y-AD-1C0-300E 945-L4Y-AD-1C0 945-E3Y-AD-1C0-180E 945-G3Y-AD-1C0-300E
Max. Sensing Distance 600 mm (23.6 in.) 200 mm (7.87 in.) 600 mm (23.6 in.) 600 mm (23.6 in.) 150 mm (5.9 in.)
Min. Sensing Distance 150 mm (5.9 in.) 60 mm (2.36 in.) 100 mm (3.9 in.) 150 mm (5.9 in.) 30 mm (1.18 in.)
Beam Angle 8°8°10°8°8°
POWER SUPPLY
Supply Voltage 19 - 30 VDC
Supply Current <20 mA without load
Circuit Protection Reverse polarity
OUTPUT CHARACTERISTICS
Load Current 10 mA max.
Switching Frequency 10 Hz 20 Hz 10 Hz 10 Hz 20Hz
Repeatability 0.3% of reading
Linearity <0.2%
Output Adjustment 4 turn potentiometer
Circuit Protection Short Circuit
ENVIRONMENTAL
Operating
Temperature 0 to 50°C (32 to 122°F)
Storage Temperature 0 to 70°C (32 to 158°F)
Sealing IP 65
SPECIAL FEATURES
Hold Input Stops transmission and reception of sensor when input is connected to 0 VDC. Analog output would be zero VDC
Synchronous Input Avoids mutual interference from several ultrasonic sensors (external synchronization unit is required; see accessories)
LED Indicator Illuminates when sensor detects a target
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Sensors 945 Series
Precision Analog 18 mm Diameter
Honeywell 1MICRO SWITCH Sensing and Control 11-800-537-6945 USA 1F1-815-235-6847 International 11-800-737-3360 Canada B93
WIRING DIAGRAMS
945-F/L, 945-E/G Series
*Normal operation with connection to 19-30 VDC
MOUNTING DIMENSIONS (For reference only)
945-F/L Series Housing 945-E/G Series with External Head
ACCESSORIES
Catalog Listing Features
Synchronization unit 55000001 Controls up to 100 sensors
Mounting clamp, 18 mm housing 43178389-018 Allows mounting to flat surface
Beam deflector 43192871-003 Allows right angle mounting (approx. dim. 50 x 170 mm)
Focusing beam deflector 43192871-004 Reduces beam angle by approximately 50%
Proximity
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
94X Series
(942-O4N-2D-1A1/1A2-80E,
943-O4V-2D-001/002/1C0/1D0-80E,
947-O4V-2D-1C0/1D0-80E)
Ultrasonic Distance Sensors
DESCRIPTION
This collection of ultrasonic devices offers enhanced sensing
range capability in a square plastic housing. Available sensor
types include programmable, Teach-In, and analogue and
fixed output versions.
FEATURES
Non contact distance sensing for use in non invasive
measurement
Reduced sensitivity to light intensity/reflectivity/opacity of
target for enhanced flexibility and certainty of measurement
Detects over much longer distance than other detection
methods reducing the need for close proximity to the target
Extremely long sensing distance (up to 6 m [19.65 ft])
reducing the need for close proximity measurement which
can be critical for some applications
POTENTIAL APPLICATIONS
Level measurement
Presence/absence detection
Distance measurement
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
943 Series (942-O4N-2D-1A1/1A2-80E,
943-O4V-2D-001/002/1C0/1D0-80E, 947-O4V-2D-1C0/1D0-80E)
2 www.honeywell.com/sensing
Specifications
Parameter 942-O4N-2D-
1A1-80E
942-O4N-2D-
1A2-80E
943-O4V-2D-
001-80E
943-O4V-2D-
002-80E
943-O4V-2D-
1C0-80E
943-O4V-2D-
1D0-80E
947-O4V-2D-
1C0-80E
947-O4V-2D-
1D0-80E
Max. sensing distance 6000 mm [236.22 in] 5000 mm [196.85 in]
Min. sensing distance 600 mm [23.62 in] 500 mm [19.69 in]
Expected response time 90%
of final value
250 ms/prog 700 ms 400 ms
Beam angle 8º 10º
Switching frequency 7 Hz/prog 0.5 Hz 7 Hz/prog
Linearity error <0.3% <0.5 %
Hysteresis prog ~1%
Repeatability of measured
distance
0.2% –
0.2% ±2 mm [0.08 in] 0.2%
Temperature range -15 °C to 70 °C [-5 °F to 158 °F]
Temperature compensation yes –
Operating voltage 15 Vdc to 30 Vdc 12 Vdc to 30 Vdc 15 Vdc to 30 Vdc 24 Vdc ±20%
Expected current consumption 100 mA <80 mA <35 mA <40 mA
Analogue output 0 V to 10 V/4 mA to 20 mA 0 V to 10 V 4 mA to 20 mA 0 V to 10 V 4 mA to 20 mA
Analogue output selection by
load
load >2 kOhm Uout
load <500 Ohm Iout
Switching outputs 2 PNP NO/NC 2 NPN NO/NC 2 PNP NO/NC 2 NPN NO/NC
Expected output current 100 mA max. 500 mA max.
Adjustment programming Teach-In
Alignment LED
Status switching output 1
Status switching output 2
green (1)
yellow (2)
yellow (3)
Control input
Inhibit connect to:
Synchronisation connect to:
Enable connect to:
Pin 6 0 V
Pin 6 Pin 6
Pin 6 NC
Pin 2 0 V
Pin 2 Pin 2
Pin 2 NC
Interface RS232
Plastic housing PBPT
Sealing* IP65
Connector 8 pin M16x0.75 5 pin M12x1
*Attention! Do not expose sensor head to hot water >50 °C or steam vapour.
Accessories: 942-O4N-2D-1A1/1A2-80E
Catalog Listing Description
66195126-001 Mating connector straight
55000005-002 Programming adaptor
55000010-001 Software programming adaptor and PC connection cable
55000018-001 Programming cable
Accessories: 943-O4V-2D-001/002-80E, 943-O4V-2D-1C0/1D0-80E, 947-O4V-2D-1C0/1D0-80E
Catalog Listing Description
66195044-001 Mating connector straight
66195045-001 Mating connector angled
66195214-001 Straight cable/connector 2 m
66195216-001 Right-angle cable/connector 2 m
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Distance Sensors
Honeywell Sensing and Control 3
Mounting Dimensions (For reference only. mm/[in])
942-O4N-2D-1A1/1A2-80E 943-O4V-2D-001/002/1C0/1D0-80E,
947-O4V-2D-1C0/1D0-80E
Wiring
P42-O4N-2D-1A1/1A2-80E 943-O4V-2D-001-80E
View to solder pins of connector
1
2
3
4
5
8
76
Pin 1: + 24 Vdc
Pin 2: GND
Pin 3: U/I
Pin 4: SP1
Pin 5: SP2
Pin 6: Hld/Sync
Pin 7: RxD
Pin 8: TxD
Pin 1
Pin 5
+24 Vdc
Teach-In
Switching output SP1
0 V
Pin 4
Pin 2
Pin 3
Switching output SP2
R
R12
34
5
943-O4V-2D-002-80E 943-O4V-2D-1C0/1D0-80E
Pin 1
Pin 2
+24 Vdc
Switching output 2
0 V
Pin 4
Pin 5
Pin 3
Switching output 1
12
34
5
Load
Load
Teach-In
Pin 1
Pin 4
+24 V
Pin 5
Pin 3
12
3
4
5
0 V/GND
Analogue
Teach-In
947-O4V-2D-1C0/1D0-80E 947-O4V-2D-1C0-80E 947-O4V-2D-1D0-80E
Pin 1
Pin 4
+24 Vdc
Analogue output
0 V
Pin 2
Pin 3
12
34
Synchronisation
Enable
Inhibit
10 V
0 V
500 mm 5000 mm
20 mA
4 mA
500 mm 5000 mm
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Automation and Control Solutions
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 55422
www.honeywell.com/sensing
004451-1-EN IL50 GLO Printed in USA
February 2006
Copyright © 2006 Honeywell International Inc. All rights reserved.
Detection Range
942-O4N-2D-1A1/1A2-80E,
943-04V-2D-001/002/1C0/1D0-80E
947-04V-2D-1C0/1D0-80E
+1000
-1000
mm
0 600 6000
Enhanced detection of a target 100 mm² x 100 mm²
Possible detection of a large target
mm
+600
-600
mm
0 500 5000
Enhanced detection of a target 100 mm² x 100 mm²
Possible detection of a large target
mm
W
ARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
W
ARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific +65 6355-2828
+65 6445-3033 Fax
Europe +44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Sensing and Control
!
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product
sheet (or catalogue) is for reference only.
DO NOT USE this document as product
installation information.
Complete installation, operation and
maintenance information is provided in the
instructions supplied with each product.
Failure to comply with these instructions
could result in death or serious injury.
943 Series
Ultrasonic Distance Sensors
Analogue voltage output
0-10 V and 4-20 mA
Beam angle:
Supply voltage: 15 to 30 V
Sealing: IP67
M30
Housing: M30 x 1,5 mm plastic (PBTB)
Max. sensing distance: 3500 mm
Min. sensing distance: 300 mm
Response time: 400 ms
Repeatability: 0,2 % or ±2 mm
OUTPUT TERMINATION REFERENCE
0-10 V Connector 943-T4V-2D-1C0-130E
0-10 V Cable 943-T4Y-2D-1C0-130E
4-10 mA Connector 943-T4V-2D-1D0-130E
4-20 mA Cable 943-T4Y-2D-1D0-130E
M18
Housing: M18 x 1,0 mm plastic (PBTB)
Max. sensing distance: 2000 mm
Min. sensing distance: 200 mm
Switching frequency: 250 ms
Repeatability: 0,2 % or ±2 mm
OUTPUT TERMINATION REFERENCE
0-10 V Connector 943-F4V-2D-1C0-180E
0-10 V Cable 943-F4Y-2D-1C0-180E
4-10 mA Connector 943-F4V-2D-1D0-180E
4-20 mA Cable 943-F4Y-2D-1D0-180E
Max. sensing distance: 800 mm
Min. sensing distance: 100 mm
Switching frequency: 100 ms
Repeatability: 0,2 % or ±1 mm
OUTPUT TERMINATION REFERENCE
0-10 V Connector 943-F4V-2D-1C0-300E
0-10 V Cable 943-F4Y-2D-1C0-300E
4-10 mA Connector 943-F4V-2D-1D0-300E
4-20 mA Cable 943-F4Y-2D-1D0-300E
Max. sensing distance: 500 mm
Min. sensing distance: 60 mm
Switching frequency: 100 ms
Repeatability: 0,2 % or ±1 mm
OUTPUT TERMINATION REFERENCE
0-10 V Connector 943-F4V-2D-1C0-330E
0-10 V Cable 943-F4Y-2D-1C0-330E
4-10 mA Connector 943-F4V-2D-1D0-330E
4-20 mA Cable 943-F4Y-2D-1D0-330E
!
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices, or in any other application
where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
OPTIONS AND ORDER GUIDE
2 switching outputs
PNP NO and NPN NO
Beam angle:
Supply voltage: 12 to 30 V
Sealing: IP67
M30
Housing: M30 x 1,5 mm plastic (PBTB)
Max. sensing distance: 3500 mm
Min. sensing distance: 300 mm
Switching frequency: 1.0 Hz
Repeatability: 0,2 % or 2 mm
OUTPUT TERMINATION REFERENCE
PNP, 2 NO/NC Connector 943-T4V-2D-001-130E
PNP, 2 NO/NC Cable 943-T4Y-2D-001-130E
NPN, 2 NO/NC Connector 943-T4V-2D-002-130E
NPN, 2 NO/NC Cable 943-T4Y-2D-002-130E
M18
Housing: M18 x 1,0 mm plastic (PBTB)
Max. sensing distance: 2000 mm
Min. sensing distance: 200 mm
Switching frequency: 1.2 Hz
Repeatability: 0,2 % or 2 mm
OUTPUT TERMINATION REFERENCE
PNP, 2 NO/NC Connector 943-F4V-2D-001-180E
PNP, 2 NO/NC Cable 943-F4Y-2D-001-180E
NPN, 2 NO/NC Connector 943-F4V-2D-002-180E
NPN, 2 NO/NC Cable 943-F4Y-2D-002-180E
Max. sensing distance: 800 mm
Min. sensing distance: 100 mm
Switching frequency: 4.7 Hz
Repeatability: 0,2 % or 1 mm
OUTPUT TERMINATION REFERENCE
PNP, 2 NO/NC Connector 943-F4V-2D-001-300E
PNP, 2 NO/NC Cable 943-F4Y-2D-001-300E
NPN, 2 NO/NC Connector 943-F4V-2D-002-300E
NPN, 2 NO/NC Cable 943-F4Y-2D-002-300E
Max. sensing distance: 500 mm
Min. sensing distance: 60 mm
Switching frequency: 4.7 Hz
Repeatability: 0,2 % or 1 mm
OUTPUT TERMINATION REFERENCE
PNP, 2 NO/NC Connector 943-F4V-2D-001-330E
PNP, 2 NO/NC Cable 943-F4Y-2D-001-330E
NPN, 2 NO/NC Connector 943-F4V-2D-002-330E
NPN, 2 NO/NC Cable 943-F4Y-2D-002-330E
The new 943 series industrial
sensors are the latest addition to
our product range. They have
improved scanning ranges, remote
teach in of the switching or
analog outputs, as well as new
advanced features, such as window
and hysteresis modes.
M18
CONNECTOR
3,5
CABLE
M30
CONNECTOR
M30 x 1,5
5,0 11,2
CABLE
5,0
M30 x 1,5
123,5 ±0,5
90 ±0,5 2000 ± 100
M18/M30
Termination: Connector M12 x 1
Cable Preleaded 2 m
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free of defective material
and faulty workmanship. Contact your local sales office for warranty information.
If warranted goods are returned to Honeywell during that period of coverage,
Honeywell will repair or replace without charge those items it finds defective.
The foregoing is Buyer’s sole remedy and is in lieu of all other warranties,
expressed or implied, including those of merchantability and fitness for a
particular purpose.
While we provide application assistance, personally, through our literature
and the Honeywell web site, it is up to the customer to determine the suitability of
the product in the application.
Specifications may change at any time without notice. The information we
supply is believed to be accurate and reliable as of this printing. However, we
assume no responsibility for its use.
This publication does not constitute a contract between Honeywell and its customers. The contents may be changed at any time without notice. It is the customer’s
responsibility to ensure safe installation and operation of the products. Detailed mounting drawings of all products illustrated are available on request.
Copyright 2004 Honeywell International Inc. All Rights Reserved.
Sensing and Control
www.honeywell.com/sensing
Honeywell Control Systems Ltd
Newhouse Industrial Estate
Motherwell, Lanarkshire ML1 5SB
Scotland, UK
100464-EN Issue 1 02/04 UK07 GLO
Sales and Service
Honeywell serves its customers through a worldwide network of sales offices,
representatives and distributors. For application assistance, current specifications,
pricing or name of the nearest Authorised Distributor, contact your local sales
office or:
INTERNET: www.honeywell.com/sensing
E-mail: info.sc@honeywell.com
ASIA PACIFIC
Control Products
Asia Pacific Headquarters
Phone: +(65) 6355-2828
FAX: +(65) 6445-3033
Australia
Honeywell Limited
Phone: +(61) 2-9370-4500
FAX: +(61) 2-9370-4525
Toll Free 1300-36-39-36
Toll Free Fax: 1300-36-04-70
China – PRC - Beijing
Honeywell China Inc.
Phone: +(86-10) 8458-3280
FAX: +(86-10) 8458-3102
China – PRC - Shanghai
Honeywell China Inc.
Phone: (86-21) 6237-0237
FAX: (86-21) 6237-1237
China - Hong Kong S.A.R.
Honeywell Ltd.
Phone: +(852) 2953-6412
FAX: +(852) 2953-6767
Indonesia
Honeywell Indonesia Pte Ltd.
Phone: +(62) 21-535-8833
FAX: +(62) 21-5367 1008
India
TATA Honeywell Ltd.
Phone: +(91) 20 6870 445/446
FAX: +(91) 20 681 2243/ 687 5992
Japan
Honeywell Inc
Phone: +(81) 3 5440 1425
FAX: +(81) 3 5440 1368
South Korea
Honeywell Korea Co Ltd
Phone: +(822) 799-6167
FAX: +(822) 792-9013
Malaysia
Honeywell Engineering Sdn Bhd
Phone: +(60-3) 7958-4988
FAX: +(60-3) 7958-8922
New Zealand
Honeywell Limited
Phone: +(64-9) 623-5050
FAX: +(64-9) 623-5060
Toll Free (0800) 202-088
Philippines
Honeywell Systems
(Philippines) Inc.
Phone: +(63-2) 636-1661/1662
FAX: +(63-2) 638-4013
Singapore
Honeywell South East Asia
Phone: +(65) 6355-2828
FAX: +(65) 6445-3033
Thailand
Honeywell Systems (Thailand)
Ltd.
Phone: +(662) 693-3099
FAX: +(662) 693-3085
Taiwan R.O.C.
Honeywell Taiwan Ltd.
Phone: +(886-2) 2245-1000
FAX: +(886-2) 2245-3241
EUROPE
Austria
Honeywell Austria GmbH
Phone: +(43) 1 727 80 366/246
FAX: +(43) 1 727 80 337
Belgium
Honeywell SA/NV
Phone: +(32) 2 728 2522
FAX: +(32) 2 728 2502
Bulgaria
Honeywell EOOD
Phone: +(359) 2 979 00 23
FAX: +(359) 2 979 00 24
Czech Republic
Honeywell spol. s.r.o.
Phone: +(420) 242 442 111
FAX: +(420) 242 442 182
Denmark
Honeywell A/S
Phone: +(45) 39 55 55 55
FAX: +(45) 39 55 55 58
Finland
Honeywell OY
Phone: +(358) 9 3480101
FAX: +(358) 9 34801375
France
Honeywell SA
Phone: +(33) 1 60 19 80 40
FAX: +(33) 1 60 19 81 73
Germany
Honeywell AG
Phone: +(49) 69 8064 444
FAX: +(49) 69 8064 442
Hungary
Honeywell Kft.
Phone: +(361) 451 43 00
FAX: +(361) 451 43 43
Italy
Honeywell S.p.A.
Phone: +(39) 02 92146 450/456
FAX: +(39) 02 92146 490
The Netherlands
Honeywell B.V.
Phone: +(31) 20 565 69 11
FAX: +(31) 20 565 66 00
Norway
Honeywell A/S
Phone: +(47) 66 76 20 00
FAX: +(47) 66 76 20 90
Poland
Honeywell Sp. zo.o
Phone: +(48) 606 09 64
FAX: +(48) 606 09 01
Portugal
Honeywell Portugal Lda
Phone: +(351 21) 424 50 00
FAX: +(351 21) 424 50 99
Romania
Honeywell Bucharest
Phone: +(40) 21 231 64 37/38
FAX: +(40) 21 231 6439
Commonwealth of
Independent States (CIS)
Z.A.O. Honeywell
Phone: +(7 095) 796 98 36
FAX: +(7 095) 797 99 06
Slovak Republic
Honeywell s.r.o.
Phone: +(421 2) 58 247 403
FAX: +(421 2) 58 247 415
South Africa (Republic of)
Honeywell Southern Africa
Honeywell S.A. Pty. Ltd
Phone: +(27) 11 695 8000
FAX +(27) 11 805 1504
Spain
Honeywell S.A.
Phone: +(34) 91 313 6100
FAX: +(34) 91 313 6129
Sweden
Honeywell AB
Phone: +(46) 8 775 55 00
FAX: +(46) 8 775 56 00
Switzerland
Honeywell AG
Phone: +(41) 1 855 24 40
FAX: +(41) 1 855 24 45
Turkey
Honeywell Turkey A.S.
Phone: +(90) 216 5756620
FAX: +(90) 216 5756637
Ukraine
Honeywell
Phone: +(380) 44 201 44 74
FAX: +(380) 44 201 44 75
United Kingdom
Honeywell Control Systems
Ltd
Phone: +(44) 1698 481481
FAX: +(44) 1698 481676
Mediterranean & African
Distributors
Honeywell SpA
Phone: +(39) 2 921 46 232
FAX: +(39) 2 921 46 233
Middle East Headquarters
Honeywell Middle East Ltd.
Phone: +(9712) 443 2119
FAX +(9712) 443 2536
NORTH AMERICA
USA/Canada
Honeywell
Sensing and Control
Phone: 1-800-537-6945
1-815-235-6847
FAX: 1-815-235-6545
E-mail:
info.sc@honeywell.com
LATIN AMERICA
Honeywell Latin America
Headquarters
Phone: 1-305-805-8188
FAX: 1-305-883-8257
Argentina
Honeywell S.A.I.C.
Phone: +(54-11) 4383-3627
FAX: +(54-11) 4325-6470
Brazil
Honeywell Do Brasil & Cia
Phone: +(55-11) 4166-1900
FAX: +(55-11) 4166-1901
Chile
Honeywell Chile, S.A.
Phone: +(56-2) 425-8400
FAX: +(56-2) 425-8410
Mexico
Honeywell S.A. de C.V.
Phone: +(52) 55 5081-0200
FAX: +(52) 55 5081-0202
Puerto Rico, Caribbean
Honeywell Inc.
Phone: +(787) 792-7075
FAX: +(787) 792-0053
Venezuela
Honeywell C.A.
Phone: +(58-212) 273-0511
FAX: +(58-212) 273-0599
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
943 Series (943-
F4V/F4Y-2D-
001/002/1C0/1D0-360E)
Ultrasonic Distance Sensors
DESCRIPTION
The new 943-F4V (connector) and 943-F4Y (cable) Series
industrial sensors are the latest additions to our range of
ultrasonic distance sensors. They offer improved scanning
ranges and remote Teach-In of the switching or analog
outputs, in addition to new, advanced features, such as
Window and Hysteresis modes. The devices are Teach-In
compatible and have an M18 plastic housing.
FEATURES
Non contact distance sensing for use in non invasive
measurement
Reduced sensitivity to light intensity/reflectivity/opacity of
target for enhanced flexibility and certainty of measurement
Detects over much longer distance than other detection
methods reducing the need for close proximity to the target
Presence absence, tank fill level and diameter
measurement provides an extremely robust and flexible
measurement method
Short distance (in ultrasonic terms) for enhanced accuracy,
repeatability (material independent) measurement to 30
mm [1.18 in].
POTENTIAL APPLICATIONS
Reel diameter measurement
Tank level measurement
Presence/absence of an object
Loop control
Product height measurement
Tire manufacturing
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
943 Series (943-F4V/F4Y-2D-001/002/1C0/1D0-360E)
2 www.honeywell.com/sensing
Specifications
Parameter 943-F4V-2D-
001-360E
943-F4V-2D-
002-360E
943-F4V-2D-
1C0-360E
943-F4V-2D-
1D0-360E
943-F4Y-2D-
001-360E
943-F4Y-2D-
002-360E
943-F4Y-2D-
1C0-360E
943-F4Y-2D-
1D0-360E
Max. sensing distance 400 mm [15.75 in]
Min. sensing distance 30 mm [1.18 in]
Expected response
time 90% of final value
60 ms 60 ms
Beam angle 8º
Switching frequency 15 Hz 15 Hz
Linearity error <0.5% <0.5%
Hysteresis 1% 1%
Repeatability of
measured distance
±1 mm [0.039 in] ±0.2%
Temperature range -15 °C to 70 °C [-5 °F to 158 °F]
Temperature
compensation
yes
Operating voltage 12 Vdc to 30 Vdc 15 Vdc to 30 Vdc 12 Vdc to 30 Vdc 15 Vdc to 30 Vdc
Possible min. supply 12 Vdc 12 Vdc
Expected current
consumption
<80 mA <40 mA <80 mA <40 mA
Output 2X PNP NO/NC 2X NPN NO/NC 0 V to 10 V 4 mA to 20 mA 2X PNP NO/NC 2X NPN NO/NC 0 V to 10 V 4 mA to 20 mA
Expected output
current
500 mA max. 500 mA max.
Adjustment set point Teach-In Teach-In
Teach-In input pin 5 pink wire
Sensitivity
Teach-In: P1/P2
determines output
position
– Teach-In – Teach-In
Plastic housing PBPT M18x1
Sealing* IP65
Connector M12x1
Cable connection 2 m [6.56 ft]
*Attention! Do not expose sensor head to hot water >50 °C or steam vapour.
Accessories: 943-F4V-2D-001/002/1CO/1DO-360E
Catalog Listing Description
66195044-001 Mating connector straight
66195045-001 Mating connector angled
66195214-001 Straight cable/connector 2 m
66195216-001 Right-angle cable/connector 2 m
43178389-018 Mounting clamp
43192871-003 Beam deflector
43192871-004 Focusing beam deflector
Accessories: 943-F4Y-2D-001/002/1CO/1DO-360E
Catalog Listing Description
43178389-018 Mounting clamp
43192871-003 Beam deflector
43192871-004 Focusing beam deflector
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Distance Sensors
Honeywell Sensing and Control 3
Mounting Dimensions Continued (For reference only. mm/[in])
943-F4V-2D-001/002/1C0/1D0-360E
943-F4Y-2D-001/002/1C0/1D0-360E
Wiring
943-F4V-2D-001-360E 943-F4V-2D-002-360E
Pin 1
Pin 5
+24 Vdc
Teach-In
Switching output SP1
0 V
Pin 4
Pin 2
Pin 3
Switching output SP2
R
R12
3
4
5
Pin 1
Pin 5
+24 Vdc
Switching output SP1
0 V
Pin 4
Pin 2
Pin 3
Switching output SP2
12
34
5
RR
Teach-In
943-F4V-2D-1C0/1D0-360E 943-F4Y-2D-001/002-360E
Pin 1
Pin 4
+24 V
Pin 5
Pin 3
1
5
34
2
0 V/GND
Analogue
Teach-In
+24 Vdc
0 V
RR
Grey SP2
Black SP1
Teach-In
Pink
Brown
Blue
943-F4Y-2D-1C0/1D0-360E Detection Range
+24 V
Pink
Blue
0 V/GND
Analogue
Teach-In
Black
Brown
+130
-130
mm
0 30 400
Enhanced detection of a target 100 mm² x 100 mm²
Possible detection of a large target
mm
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Automation and Control Solutions
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 61032
www.honeywell.com/sensing
004452-1-1-EN IL50 GLO Printed in USA
February 2006
Copyright © 2006 Honeywell International Inc. All rights reserved.
W
ARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
W
ARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific +65 6355-2828
+65 6445-3033 Fax
Europe +44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
943 Series (943-G4V-
2G-001/002-400E)
Ultrasonic Distance Sensors
DESCRIPTION
The new 943-G4V series industrial sensors are the latest
addition to our range of ultrasonic distance sensors. They offer
improved scanning ranges and remote Teach-In of the
switching or analogue outputs, in addition to new, advanced
features, such as Window and Hysteresis modes. The devices
are Teach-In compatible and have an M12 stainless steel
housing for the 943 G4V.
FEATURES
Non contact distance sensing for use in non invasive
measurement
Reduced sensitivity to light intensity/reflectivity/opacity of
target for enhanced flexibility and certainty of measurement
Detects over much longer distance than other detection
methods reducing the need for close proximity to the target
Short distance (in ultrasonic terms) for accuracy,
repeatability (material independent) measurement to
25 mm [0.98 in].
POTENTIAL APPLICATIONS
Reel diameter measurement
Tank level measurement
Presence/absence of an object
Loop control
Product height measurement
Tire manufacturing
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
943 Series (943-G4V-2G-001/002-400E)
2 www.honeywell.com/sensing
Specifications
Parameter 943-G4V-2G-001-400E 943-G4V-2G-002-400E
Max. sensing distance 250 mm [9.84 in]
Min. sensing distance 25 mm [0.98 in]
Switching frequency 30 Hz
Hysteresis 1%
Beam angle
Repeatability 0,3 mm [0.012 in]
Temperature range -20 °C to 70 °C [-4 °F to 158 °F]
Operating voltage 10 Vdc to 30 Vdc
Expected current consumption <100 mA
Output PNP NO/NC NPN NO/NC
Expected output current 100 mA max.
Adjustment set point Teach-In
Stainless steel housing M12x1
Sealing* IP65
Connector M12x1
*Attention! Do not expose sensor head to hot water >50 °C or water vapour.
Accessories
Catalog Listing Description
66195044-001 Mating connector straight
66195045-001 Mating connector angled
Mounting Dimensions (For reference only. mm/[in])
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Distance Sensors
Honeywell Sensing and Control 3
Wiring
Pin 1
Pin 4
Pin 2
Pin 3
+24 V
Teach-In
0 V
R
12
34
Detection Range
+15
-15
mm
0 25 200
Enhanced detection of a target 100 mm² x 100 mm²
Possible detection of a large target
mm
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Automation and Control Solutions
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 55422
www.honeywell.com/sensing
004449-1-EN IL50 GLO Printed in USA
February 2006
Copyright © 2006 Honeywell International Inc. All rights reserved.
W
ARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
W
ARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific +65 6355-2828
+65 6445-3033 Fax
Europe +44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
943 Series (943-K4U-
2G-001/002/1C0-400E)
Ultrasonic Distance Sensors
DESCRIPTION
The new 943-K4U series industrial sensors are the latest
addition to our range of ultrasonic distance sensors. They offer
improved scanning ranges and remote Teach-In of the
switching or analogue outputs, in addition to new, advanced
features, such as Window and Hysteresis modes. The devices
are Teach-In compatible and have a plastic housing.
FEATURES
Non contact distance sensing for use in non invasive
measurement
Reduced sensitivity to light intensity/reflectivity/opacity of
target for enhanced flexibility and certainty of measurement
Detects over much longer distance than other detection
methods reducing the need for close proximity to the target
Presence absence, tank fill level and diameter
measurement provide an extremely robust and flexible
measurement method
Miniature form factor device fits into the smallest mounting
positions
Two mounting methods provide flexibility of mounting
options to suit the application
POTENTIAL APPLICATIONS
Level measurement in small containers/test tubes
Small object detection in narrow environments
Presence detection
Winding/unwinding control
Height/thickness measurement
Parts counting
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
943 Series (943-K4U-2G-001/002/1C0-400E)
2 www.honeywell.com/sensing
Specifications
Parameter 943-K4U-2G-001-400E 943-K4U-2G-002-400E 943-K4U-2G-1C0-400E
Max. sensing distance 250 mm [9.84 in]
Min. sensing distance 25 mm [0.98 in]
Switching frequency 25 Hz
Linearity error <0.3%
Hysteresis 2%
Repeatability of measured distance - ±0.2 mm [0.008 in]
±0.2%
Beam angle
Temperature range -25 °C to 70 °C [-13 °F to 158 °F]
Temperature compensation yes
Operating voltage 10 Vdc to 30 Vdc 12 Vdc to 30 Vdc
Expected current consumption <100 mA
Output PNP NO/NC NPN NO/NC 0 V to 10 V
Expected output current 100 mA max.
Adjustment set point Teach-In
Adjustment – Teach-In
Housing material plastic
Sealing* IP67
Connector M8
*Attention! Do not expose sensor head to hot water >50 °C or steam vapour.
Mounting Dimensions (For reference only. mm/[in])
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Distance Sensors
Honeywell Sensing and Control 3
Wiring
943-K4U-2G-001-400E 943-K4U-2G-002-400E 943-K4U-2G-1C0-400E
Pin 1
Pin 2
Pin 4
Pin 3
+24 V
Teach-In
Switching output
0 V
13
4
2
R
Pin 1
Pin 2
Pin 4
Pin 3
+24 V
Teach-In
0 V
13
42
R
Pin 1
Pin 2
Pin 4
Pin 3
+24 V
Teach-In
0 V
R13
42
Detection Range
+15
-15
mm
0 25 250
Enhanced detection of a target 100 mm² x 100 mm²
Possible detection of a large target
mm
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Automation and Control Solutions
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 55422
www.honeywell.com/sensing
004450-1-EN IL50 GLO Printed in USA
February 2006
Copyright © 2006 Honeywell International Inc. All rights reserved.
W
ARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
W
ARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific +65 6355-2828
+65 6445-3033 Fax
Europe +44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
948 Series (948-ISY-
2D-001/002/003/004-
180E)
Ultrasonic Distance Sensors
DESCRIPTION
The 948 Series is one of the smallest ultrasonic scan through
devices in the world. Its small, rectangular, IP67-rated plastic
housing makes it easy to install in limited space applications.
The sensor consists of two parts, a transmitter and a receiver.
It is especially suited for food and beverage applications, in
particular bottle counting.
FEATURES
Thru-scan detection regardless of the object material for
enhanced detection
Non contact distance sensing for use in non invasive
measurement
Reduced sensitivity to light intensity/reflectivity/opacity of
target for enhanced flexibility and certainty of measurement
Detects over much longer distance than other detection
methods reducing the need for close proximity to the target
Presence absence, tank fill level and diameter
measurement provides an extremely robust and flexible
measurement method
POTENTIAL APPLICATIONS
Food and beverage machinery and equipment
Rapid presence/absence detection: bottle counting
Loop control
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
948 Series (948-ISY-2D-001/002/003/004-180E)
2 www.honeywell.com/sensing
Specifications
Parameter 948-ISY-2D-001-180E 948-ISY-2D-002-180E 948-ISY-2D-003-180E 948-ISY-2D-004-180E
Sensing distance 1100 mm [3.61 ft]
Response time on/off 3 ms
Beam angle 15º
Output NO PNP NO NPN NC PNP NC NPN
Expected output current 500 mA
Switching frequency 150 Hz
Temperature range -15 °C to 60 °C [-5 °F to140 °F]
Operating voltage 18 Vdc to 30 Vdc
Expected current
consumption
<40 mA
Housing plastic
Sealing IP67
Cable connection 2 m [6.56 ft]
Sensor consists of 2 parts: 1 transmitter and 1 receiver.
With flat targets best results may be achieved with an angle 30° object-ultrasonic beam.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Ultrasonic Distance Sensors
Honeywell Sensing and Control 3
Mounting Dimensions (For reference only. mm/[in])
Transmitter
Brown: Vdc
Blue: 0 V
Receiver
Brown: Vdc
Blue: 0 V
Black: O/P
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com
Automation and Control Solutions
Sensing and Control
Honeywell
1985 Douglas Drive North
Minneapolis, MN 55422
www.honeywell.com/sensing
004448-1-EN IL50 GLO Printed in USA
February 2006
Copyright © 2006 Honeywell International Inc. All rights reserved.
W
ARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
W
ARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific +65 6355-2828
+65 6445-3033 Fax
Europe +44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.DataSheet4U.com