1/2 step 1/4 step 1/8 step VREF phase A VREF phase B Sequencer value
2 3 5 70.711% 70.711% 0010000000
6 83.147% 55.557% 0010100000
4 7 92.388% 19.509% 0011100000
8 98.079% 19.509% 0011100000
3 5 9 100% 0% 0100000000
10 98.079% -19.509% 0100100000
6 11 92.388% -38.268% 0101000000
12 83.147% -55.557% 0101100000
4 7 13 70.711% -70.711% 0110000000
14 55.557% -83.147% 0110100000
8 15 38.268% -92.388% 0111000000
16 19.509% -98.079% 1000100000
5 9 17 0% 100% 1000000000
18 -19.509% -98.079% 1000100000
10 19 -38.268% -92.388% 1001000000
20 -55.557% -83.147% 1001100000
6 11 21 -70.711% -70.711% 1010000000
22 -83.147% -55.557% 1010100000
12 23 -92.388% -38.268% 1011000000
24 -98.079% -19.509% 1011100000
7 13 25 -100% 0% 1100000000
26 -98.079% 19.509% 1100100000
14 27 -92.388% 38.268% 1101000000
28 -83.147% 55.557% 1101100000
8 15 29 -70.711% 70.711% 1110000000
30 -55.557% 83.147% 1110100000
16 31 -38.268% 92.388% 1111000000
32 -19.509% 98.079% 1111100000
Note: The positive number means that the output current is flowing from OUTx1 to OUTx2, vice versa for a negative
value.
6.3 PWM current control
The device implements two independent PWM current controllers, one for each full bridge.
The voltage of the sense pins (VSENSEA and VSENSEB) is compared to the respective internal reference generated
based on the sequencer value (see Table 9. Target reference and current direction according to sequencer value
(full-step mode) and Table 10. Target reference and current direction according to sequencer value (not full-step
mode)).
When VSENSEX > VREFX, the integrated comparator is triggered, the OFF time counter is started and the decay
sequence is performed.
The decay sequence starts turning on both the low sides of the full bridge. When 5/8ths of the programmed OFF
time (tOFF,SLOW) has expired, the decay sequence performs a quasi-synchronous fast decay.
STSPIN220
PWM current control
DS11633 - Rev 4 page 12/27