GU Form A & B (AQW614) Both NO and NC contacts incorporated in a DIP8-pin package 6.4 .252 9.78 .385 3.9 .154 6.4 .252 9.78 .385 3.6 .142 mm inch 1 N.C. 8 2 7 3 6 4 GU Form A & B (AQW614) FEATURES TYPICAL APPLICATIONS 1. Approx. 1/2 the space compared with the mounting of a set of 1 Form A and 1 Form B PhotoMOS 2. Applicable for 1 Form A 1 Form B use as well as two independent 1 Form A and 1 Form B use 3. Controls load currents up to 0.13 A with 5 mA input current 4. Extremely low closed-circuit offset voltages to enable control of small analog signals without distortion 5. Stable on-resistance * High-speed inspection machines * Telephone equipment * Computers * Sensing equipment 5 N.O. RoHS compliant TYPES Output rating* AC/DC dual use Part No. Load voltage Load current Package 400 V 100 mA DIP8-pin Through hole terminal Tape and reel packing style Picked from the Picked from the 1/2/3-pin side 4/5/6-pin side Tube packing style AQW614 Packing quantity Surface-mount terminal AQW614A AQW614AX AQW614AZ Tube Tape and reel 1 tube contains: 50 pcs. 1 batch contains: 500 pcs. 1,000 pcs. *Indicate the peak AC and DC values. Note: The surface mount terminal shape indicator "A" and the packing style indicator "X" or "Z" are not marked on the device. RATING 1. Absolute maximum ratings (Ambient temperature: 25C 77F) Item LED forward current LED reverse voltage Peak forward current Power dissipation Load voltage (peak AC) Symbol IF VR IFP Pin VL AQW614(A) 50 mA 5V 1A 75 mW 400 V Continuous load current IL 0.1 A (0.13 A) Total power dissipation Ipeak Pout PT 0.3 A 800 mW 850 mW I/O isolation voltage Viso 1,500 V AC Topr Tstg -40C to +85C -40F to +185F -40C to +100C -40F to +212F Input Output Peak load current Power dissipation Temperature limits Operating Storage Panasonic Corporation Automation Controls Business Unit Remarks f = 100 Hz, Duty factor = 0.1% Peak AC, DC ( ): in case of using only 1a or 1b, 1 channel 100 ms (1 shot), VL = DC Between input and output/between contact sets Non-condensing at low temperatures industrial.panasonic.com/ac/e ASCTB52E 201201-T GU Form A & B (AQW614) 2. Electrical characteristics (Ambient temperature: 25C 77F) Item Typical Maximum Minimum Typical Typical Maximum LED operate current Input LED reverse current LED dropout voltage Symbol AQW614(A) IFon (N.O.) IFoff (N.C.) 0.9 mA 3 mA IFoff (N.O.) IFon (N.C.) 0.4 mA 0.8 mA 1.25 V (1.14 V at IF = 5 mA) 1.5 V VF IL = 100 mA IL = 100 mA IF = 50 mA IF = 5 mA (N.O.) IF = 0 mA (N.C.) IL = 100 mA within 1 s on time IF = 0 mA (N.O.) IF = 5 mA (N.C.) VL = 400 V 27 Typical On resistance Ron 50 Maximum Output Off state leakage current Operate time* Transfer characteristics Condition Reverse time* I/O capacitance Initial I/O isolation resistance Maximum ILeak 1 A Typical Maximum Typical Maximum Typical Maximum Minimum Ton (N.O.) Toff (N.C.) 0.28 ms (N.O.) 0.43 ms (N.C.) 1 ms 0.04 ms (N.O.) 0.3 ms (N.C.) 1 ms 0.8 pF Toff (N.O.) Ton (N.C.) Ciso IF = 0 mA 5 mA IL = 100 mA IF = 5 mA 0 mA IL = 100 mA f = 1 MHz VB = 0 V 1.5 pF 1,000 M Riso 500 V DC *Operate/Reverse time 1) N.O. 2) N.C. Input Input 90% Output Output 10% Ton 10% 90% Toff Toff Ton RECOMMENDED OPERATING CONDITIONS Please obey the following conditions to ensure proper device operation and resetting. Item Input LED current Symbol IF Recommended value 5 Unit mA For Dimensions. For Schematic and Wiring Diagrams. For Cautions for Use. These products are not designed for automotive use. If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation technical representative. For more information. REFERENCE DATA 1. Load current vs. ambient temperature characteristics 2. On resistance vs. ambient temperature characteristics 3. Operate time vs. ambient temperature characteristics Allowable ambient temperature: -40C to +85C -40F to +185F Measured portion: between terminals 5 and 6, 7 and 8; LED current: 5 mA; Load voltage: 400 V (DC); Continuous load current: 100 mA (DC) LED current: 5 mA; Load voltage: 400 V (DC); Continuous load current: 100 mA (DC) Between terminal 5 and 6 (N.O.) Between terminal 7 and 8 (N.C.) 50 Using 2 channels On resistance, Load current, mA 120 100 1.2 60 Using only 1 channel 80 60 40 30 20 40 -20 0 20 40 60 8085 100 Ambient temperature, C ASCTB52E 201201-T 0 Panasonic Corporation Between terminal 5 and 6 (N.O.) Between terminal 7 and 8 (N.C.) 1.0 0.8 0.6 0.4 0.2 10 20 0 -40 Operate (OFF) time, ms 140 -40 -20 0 20 40 60 8085 Ambient temperature, C Automation Controls Business Unit 0 -40 -20 0 20 40 60 8085 Ambient temperature, C industrial.panasonic.com/ac/e GU Form A & B (AQW614) 4. Reverse time vs. ambient temperature characteristics 5. LED operate current vs. ambient temperature characteristics 6. LED reverse current vs. ambient temperature characteristics LED current: 5 mA; Load voltage: 400 V (DC); Continuous load current: 100 mA (DC) Load voltage: 400 V (DC); Continuous load current: 100 mA (DC) Load voltage: 400 V (DC); Continuous load current: 100 mA (DC) 1.2 0.8 0.6 0.4 0.2 0 Between terminal 5 and 6 (N.O.) Between terminal 7 and 8 (N.C.) 5 4 3 2 LED reverse (NO) current, mA 1.0 6 6 LED operate (OFF) current, mA Reverse (ON) time, ms Between terminal 5 and 6 (N.O.) Between terminal 7 and 8 (N.C.) -20 0 20 40 60 0 8085 4 3 2 1 1 -40 Between terminal 5 and 6 (N.O.) Between terminal 7 and 8 (N.C.) 5 -40 -20 Ambient temperature, C 0 0 20 40 60 8085 Ambient temperature, C -40 -20 0 20 40 60 8085 Ambient temperature, C 8. Current vs. voltage characteristics of output at MOS portion 9. Off state leakage current vs. load voltage characteristics LED current: 5 to 50 mA Measured portion: between terminals 5 and 6, 7 and 8; Ambient temperature: 25C 77F Measured portion: between terminals 5 and 6, 7 and 8; Ambient temperature: 25C 77F Current, mA LED dropout voltage, V 1.5 1.4 1.3 Between terminal 7 and 8 100 (N.C.) 80 60 Between terminal 5 and 6 (N.O.) 40 20 -5 -4 -3 -2 -1 1.2 1 2 3 4 5 -20 Voltage, V -40 50mA 30mA 20mA 10mA 5mA 1.1 Off state leakage current, A 7. LED dropout voltage vs. ambient temperature characteristics 10 -3 10 -6 Between terminal 7 and 8 (N.C.) 10 -9 -60 -80 1.0 Between terminal 5 and 6 (N.O.) -100 0 -40 -20 10 -12 0 20 40 60 8085 Ambient temperature, C 20 0 40 60 80 100 Load voltage, V 10. Operate time vs. LED forward current characteristics 11. Reverse time vs. LED forward current characteristics 12. Output capacitance vs. applied voltage characteristics Measured portion: between terminals 5 and 6, 7 and 8; Load voltage: 400 V (DC); Continuous load current: 100 mA (DC); Ambient temperature: 25C 77F Measured portion: between terminals 5 and 6, 7 and 8; Load voltage: 400 V (DC); Continuous load current: 100 mA (DC); Ambient temperature: 25C 77F Measured portion: between terminals 5 and 6, 7 and 8; Frequency: 1 MHz; Ambient temperature: 25C 77F 3.0 0.6 Reverse (ON) time, ms Operate (OFF) time, ms 2.5 2.0 1.5 1.0 0.5 0 Between terminal 5 and 6 (N.O.) Between terminal 7 and 8 (N.C.) 0.5 0.4 0.3 0.2 0.1 10 20 30 40 50 LED forward current, mA 60 Panasonic Corporation 0 Output capacitance, pF 120 Between terminal 5 and 6 (N.O.) Between terminal 7 and 8 (N.C.) Between terminal 5 and 6 (N.O.) Between terminal 7 and 8 (N.C.) 100 80 60 40 20 10 20 30 40 50 LED forward current, mA Automation Controls Business Unit 60 0 10 industrial.panasonic.com/ac/e 20 30 40 50 Applied voltage, V 60 ASCTB52E 201201-T