Subject to change without notice * (c) Hans Turck GmbH & Co.KG 2002 * Edition: Hans Turck GmbH & Co.KG * Postfach * D-45466 Mulheim an der Ruhr * Telefon 02 08/49 52-0 * Telefax 02 08/49 52-264 Photoelectric sensor laser emitter QS186LEQ8 15 49 17,1 LED GN 24/8 M18 x 1 35 operational voltage 10..0.30 VDC LED visible from all sides M12 x 1 connector laser class 1 Wiring diagram 1BN + 2WH 24,1 M12 x 1 31 o 3,3 Type Ident-No. QS186LEQ8 3070253 Operating mode Type of light Wave length Laser-class Max. sensing range [m] Operating temperature Opposed mode (emitter) red 650 nm 1 (EN 60825, IEC 60825) 0... 30 m -10 ...+ 50 C Rated operational voltage (DC) UB 10... 30 VDC Rated operational current (DC) Ie 100 mA No-load current I0 35 mA Short-circuit protection Reverse polarity protection Time delay before availability yes, cyclic yes 1,5 s Housing style Dimensions Housing material Lens Wiring Degree of protection rectangular; QS18 31 x 15 x 35 mm plastic, ABS plastic, acrylic connector, M12 x 1 IP67 Supply voltage indication LED green 3BU Opposed mode sensors consist of a separate emitter and receiver. These are installed directly opposite each other so that the light from the emitter is aimed directly at the receiver. When an object interrupts or weakens the light beam, the sensor switches. Opposed mode sensors are the most reliable photoelectric sensors for detection of opaque targets. An excellent contrast between light and dark conditions and an extremly high excess gain are typical of this sensing mode, thus allowing operation over larger distances and under difficult conditions. Excess gain curve Excess gain in relation to the distance (type 6EB/RB) Subject to change without notice * (c) Hans Turck GmbH & Co.KG 2002 * Edition: * 12.04.2004 Hans Turck GmbH & Co.KG * Postfach * D-45466 Mulheim an der Ruhr * Telefon 02 08/49 52-0 * Telefax 02 08/49 52-264