Voltage V ariable Absorptive Attenuator
35 dB, DC - 2.0 GHz MAAVSS0004
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V1
1
RoHS
Compliant
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
Features
35 dB Voltage Variable Attenuation at 1 GHz
Single Voltage Control: 0 to -4 Volts
Low DC Power Consumption
Nanosecond Switching Speed
Temperature Range: -40°C to +85° C
Lead-Free SOIC-14 Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
260°C Reflow Compatible
RoHS* Compliant Versi on of AT-635
Tape and Reel Packaging Available
Description
M/A-COM’s MAAVSS0004 is a GaAs MMIC voltage
variable absorptive attenuator in a low cost SOIC
14-lead surface mount plastic package. The
MAAVSS0004 is ideally suited for use where
attenuation fine tuning, fast switching and very low
power consumption are required.
Typical applications include radio, cellular, GPS
equipment and other automatic gain/level control
circuits.
The MAAVSS0004 is fabricated with a monolithic
GaAs MMIC using a mature 1-micron process. The
process features full chip passivation for increased
performance and reliability.
Functional Schematic
814 13 12 11
1234567
10 9
Ordering Information1
Part Number Package
MAAVSS0004 Bulk packaging
MAAVSS0004TR-3000 3000 piece reel
Pin Configuration
Pin No. Function Pin No. Function
1 VC 8 RF2
2 Ground 9 Ground
3 Ground 10 Ground
4 Ground 11 Ground
5 Ground 12 Ground
6 Ground 13 Ground
7 Ground 14 RF1
Absolute Maximum Ratings 2,3
Parameter Abso lute Maximum
Input Power +21 dBm
Control Voltage -8.5 V < VC < +5 V
Operating Temperature -40°C to +85°C
Storing Temperature -65°C to +150°C
2. Exceeding any one or combination of these limits may cause
permanent damage to this device.
3. M/A-COM does not recommend sustained operation near
these survivability limits.
1. Reference Application Note M513 for reel size information.
Voltage V ariable Absorptive Attenuator
35 dB, DC - 2.0 GHz MAAVSS0004
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V1
2
RoHS
Compliant
Electrical Specifications: TA = 25°C, Z0 = 50 Ω
Parameter Test Conditions
4
Units Min. Typ. Max.
Insertion Loss DC - 0.5 GHz
0.5 - 1.0 GHz
1.0 - 2.0 GHz
dB
dB
dB
6.7
7.2
7.5
7.0
7.4
7.8
Flatness
(Peak to Peak)
10 dB Attenuation – DC - 2.0 GHz
20 dB Attenuation – DC - 2.0 GHz
30 dB Attenuation – DC - 2.0 GHz
dB
dB
dB
+ 1.0
+ 1.2
+ 1.2
VSWR Ratio 2.0:1
Trise, Tfall 10% to 90% RF, 90% to 10% RF nS 2
Ton, Toff 50% Control to 90% RF,
50% Control to 10% RF nS 4
Transients In Band mV 30
Power Handling Linear Operation
Absolute maximum Input Power dBm
dBm
13
21
IP2
0.05 GHz
0.5 - 2.0 GHz
Measured Relative to Input Power
(For two-tone Input Power Up to +5 dBm)
dBm
dBm
34
47
IP3
0.05 GHz
0.5 - 2.0 GHz
Measured Relative to Input Power
(For two-tone Input Power Up to +5 dBm)
dBm
dBm 18
18.5 31 5
36 5
4. Control voltage: 0 to -4 volts @ 20 µA typical.
5. For levels above 6 dB attenuation. For levels below 6 dB, the minimum specification numbers apply.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
Lead-Free SOIC-14
Reference Application Note M538 for lead-free solder reflow
recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
Voltage V ariable Absorptive Attenuator
35 dB, DC - 2.0 GHz MAAVSS0004
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V1
3
RoHS
Compliant
Typical Performance Curves
Insertion Loss vs. Frequen cy
Attenuation vs. Frequency VSWR vs. Frequency
Attenuation vs. Control Voltage, F = 1 GHz
0
2
4
6
8
10
12
0.0 0.5 1.0 1.5 2.0 2.5 3.0
+25°C
-40°C
+85°C
Frequency (GHz)
0
10
20
30
40
-3.0 -2.5 -2.0 -1.5 -1.0 -0.5 0.0
Control Voltage (V)
0
10
20
30
40
50
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Atten5
Atten10
Atten15
Atten20
Atten25
Atten30
Atten35
Frequency (GHz)
1.0
1.5
2.0
2.5
3.0
3.5
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Ins er tion Los s
5 dB A tt en
10 dB Atten
35 dB Atten
Frequency (GHz)