DS_AB40S/D_06112014 E-mail: DCDC@delta.com.tw
http://www.deltaww.com/dcdc
Environmental Specifications
Temperature Range (operational)
Storage Temperature Range
Over Temperature Protection
Shutdown at 90℃ (automatic recovery at approx. 67℃)
Humidity (non condensing)
This product is not designed for use in critical life support systems, equipment used in hazardous environment, nuclear control
systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet.
Specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage, after warm-up time rated output current unless
otherwise noted.
Ripple & Noise measured with a 0.1μF/50V MLCC and a 1μF/50V Aluminum electrolytic.
Safety approvals cover frequency 47-63 Hz.
We recommend to protect the converter by a slow blow fuse in the input supply line.
Other input and output voltage may be available, please contact factory.
To order the module with chassis mount package, please add a suffix C (e.g. AB40S2400C ).
To order the module in chassis mount with DIN-Rail kit, please add a suffix D (e.g. AB40S2400D).
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications are subject to change without notice.
Package Specifications PCB Mounting
►All dimensions in mm (inches)
►Pin diameter 1.0 ±0.1
(0.04±0.004)
88.9x63.5x30.0mm (3.50x2.50x1.18 inches)
Plastic resin (flammability to UL 94V-0 rated)
Copper Alloy with Gold Plate Over Nickel Subplate
31.6 [1.24]
55.88 [2.20]
63.5 [2.50]
81.3 [3.20]
88.9 [3.50]
15.24 12.7
7654 3
12
5.0
30.0
6.0
1.0
[0.60] [0.50] 12.7
[0.50] 15.24
[0.60] [0.24] [1.18]
0.7
[0.03]
[ 0.04]
[0.20]
Mounting M4.0 Thread
Bottom View
15.9 [0.63]