TISP4C015L1N THRU TISP4C035L1N
LOW CAPACITANCE
BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTOR
TISP4C0xxL1N Overvoltage Protector Series
JULY 2008 - REVISED MAY 2009
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex.
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications
SOT23-5 Package (Top View)
This range of devices is designed to protect xDSL line-driver
interfaces from overvoltages. Overvoltages are normally caused
by a.c. power-system or lightning-fl ash disturbances which are
induced or conducted onto the telephone line. These symmetri-
cal protectors are two-terminal thyristor-crowbar devices. They
can be used to protect between conductors, or a pair of devices
can be deployed to protect from line to ground. When placed
between the xDSL line driver IC and the transformer, this
*RoHS COMPLIANT
Designed for ADSL, ADSL2, VDSL, VDSL2 protection
Ion-Implanted Breakdown Region
- Precise and Stable Voltage
Low Voltage Overshoot Under Surge
Low Off-State Capacitance
Device Name VDRM
V
V(BO)
V
TISP4C015L1N 8 15
TISP4C020L1N 12 20
TISP4C025L1N 16 25
TISP4C035L1N 24 35
Rated for International Surge Wave Shapes
Wave Shape Standard IPPSM
A
8/20 IEC 61000-4-5 30
10/1000 GR-1089-CORE 18
MD-SOT23-5-001-a
Terminal typical application names
shown in parenthesis.
NU - Non-usable; no external electrical
connection should be made to this terminal.
(Ring)
1
2
34
5)piT()piT(
(Ring)
NU
Device Symbol
(Tip)
SD-TISP4-002-a
(Ring)
Description
protector will clamp and switch into a low-impedance state, safely diverting the energy transferred by the xDSL coupling transformer.
The low capacitance design makes this device suitable for designs from ADSL all the way up to 30 MHz VDSL2.
Telecom ports need protection against Common Mode (Longitudinal) and Differential (Metallic) surges, to comply with international
standards such as ITU-T K.20, K.21 or K.45, Telcordia GR-1089-CORE and YD/T. Common Mode surges are resisted by the galvanic
isolation of the coupling transformer which is commonly rated to 2 kV or greater. Differential surges can be transmitted by the
transformer, and can stress the Line Driver Interface IC. As the xDSL interface circuit is designed to operate from 3 kHz to to 30 MHz,
nearby high frequency events - such as cable fl ashover or primary protection activation - can generate damaging conditions for the
interface requiring this type of protection.
Please contact your Bourns representative if the protection voltage you require is not listed.
How to Order
ytitnauQ leeRedoC gnikraMsA redrOreirraCegakcaPeciveD
TISP4C0xxL1N SOT23-5 Embossed Tape Reeled TISP4C0xxL1NR-S Cxx 10000
Insert xx corresponding to device name.
JULY 2008 - REVISED MAY 2009
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications
TISP4C0xxL1N Overvoltage Protector Series
Absolute Maximum Ratings, TA = 25 °C (Unless Otherwise Noted)
tinUeulaVlobmySgnitaR
Repetitive peak off-state voltage
‘4C015L1N
‘4C020L1N
‘4C025L1N VDRM
±8
±12
±16
‘4C035L1N ±24
V
Non-repetitive peak impulse current (see Notes 1, 2 and 3)
8/20 µs (IEC 61000-4-5, 1.2/50 µs voltage, 8/20 current combination wave generator)
10/1000 µs (GR-1089-CORE, 10/1000 µs voltage wave shape)
IPPSM ±30
±18
A
Junction temperature TJ-40 to +150 °C
Storage temperature range Tstg -65 to +150 °C
NOTES: 1. Initially the device must be in thermal equilibrium with T
J = 25 °C.
2. The surge may be repeated after the device returns to its initial conditions.
3. Rated currents only apply if pins 1 & 5 (Tip) are connected together and pins 3 & 4 (Ring) are connected together.
tidnoC tseTretemaraP tinUxaMpyTniMsnoi
IDRM Repetitive peak off-state current VD = VDRM ±1 µA
V(BO) Breakover voltage dv/dt = ±250 V/ms, RSOURCE = 300 Ω
‘4C015L1N
‘4C020L1N
‘4C025L1N
±15
±20
±25
‘4C035L1N ±35
V
IHHolding current ITAm
05±
sm/Am03±=td/id ,A5±=
COOff-state capacitance f = 1 MHz, Vd = 1 V rms, VD = 2 V
‘4C015L1N
‘4C020L1N
‘4C025L1N
15
15
15
‘4C035L1N 15
‘4C015L1N
‘4C020L1N
‘4C025L1N
±20
±50
‘4C035L1N ±50
pF
ΔC Delta-capacitance f = 1 MHz, Vd = 1 V rms, VD = 1 V to VDRM
‘4C015L1N
‘4C020L1N
‘4C025L1N
3
3.5
3.5
‘4C035L1N 4.5
pF
Electrical Characteristics, TA = 25 °C (Unless Otherwise Noted)
JULY 2008 - REVISED MAY 2009
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications
TISP4C0xxL1N Overvoltage Protector Series
Parameter Measurement Information
-v
I(BR)
V(BR)
V(BR)M
VDRM
IDRM
VD
IH
IT
VT
ITRM
IPPSM
V(BO)
I(BO)
ID
Quadrant I
Switching
Characteristic
+v
+i
V(BO)
I(BO)
I(BR)
V(BR)
V(BR)M
VDRM
IDRM
VD
ID
IH
IT
VT
ITRM
IPPSM
-i
Quadrant III
Switching
Characteristic
ITSM
ITSM
Figure 1. Voltage-Current Characteristic for Tip and Ring Terminals
All Measurements are Referenced to the Ring Terminal
PM-TISP4xxx-001-a
JULY 2008 - REVISED MAY 2009
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications
TISP4C0xxL1N Overvoltage Protector Series
Typical Characteristics
Recommended PCB Layout
CAPACITANCE
vs
OFF-STATE VOLTAGE
VD - Off-State Voltage - V
0 2 4 6 8 10 12 14 16 18 20 22 24
Capacitance - pF
1
2
3
4
6
7
8
9
11
12
13
14
0
5
10
15
TISP4C015L1N
TISP4C025L1N
TC-4CN-001
f = 1 MHz
Vd= 1 VRMS
TJ = 25 °C
TISP4C020L1N
TISP4C035L1N
Figure 3.
MD-SOT223-5-xxx
1
2
34
5
R
T
NU
T
RPCB Track
PCB Track
“TISP” is a trademark of Bourns Ltd., a Bourns Company, and is Registered in U.S. Patent and Trademark Offi ce.
“Bourns” is a registered trademark of Bourns, Inc. in the U.S. and other countries.
Bourns Sales Offi ces
Region Phone Fax
The Americas: +1-951-781-5500 +1-951-781-5700
Europe: +41-41-7685555 +41-41-7685510
Asia-Pacifi c: +886-2-25624117 +886-2-25624116
Technical Assistance
Region Phone Fax
The Americas: +1-951-781-5500 +1-951-781-5700
Europe: +41-41-7685555 +41-41-7685510
Asia-Pacifi c: +886-2-25624117 +886-2-25624116
www.bourns.com
Bourns® products are available through an extensive global network of representatives, agents and distributors.
To obtain technical applications assistance, a quotation, or to place an order, contact a Bourns representative in your area.