R
2
Short Barrel Inductive Prox E2E2-WIREAC
Short Barrel 2-Wire AC Prox Sensors
Meet IP67
HThick nickel-plated brass barrel has wrench
flats for easy installation
HSolid potted internal circuitry withstands
shocks and water washdown to IP67
HHigh visibility indicator
HChoose prewired models with or without
short-circuit protection and connector
models
Ordering Information
JPREWIRED SENSORS WITHOUT SHORT-CIRCUIT PROTECTION
WHEN ORDERING, PLEASE NOTE: Omron has added the suffix “-N” to E2E part numbers for ordering purposes only; the suffix -N” will not
appear on the product.
Type Size Sensing distance Part number
y
p
g
NO NC
Shielded M8


































1.5 mm E2E-X1R5Y1-N E2E-X1R5Y2-N
M12


































2mm E2E-X2Y1-US-N E2E-X2Y2-US-N
M18


































5mm E2E-X5Y1-US-N* E2E-X5Y2-US-N
M30 10 mm E2E-X10Y1-US-N* E2E-X10Y2-US-N
Unshielded M8


































2mm E2E-X2MY1-US-N* E2E-X2MY2-US-N
M12


































5mm E2E-X5MY1-US-N* E2E-X5MY2-US-N*
M18 10 mm E2E-X10MY1-US-N* E2E-X10MY2-US-N*
M30
18 mm
E2E-X18MY1-US-N* E2E-X18MY2-US-N
*Note: A different oscillating frequency is available to prevent mutual interference. Add a 5” to the part number (e.g., E2E-X5Y15-US-N).
E2E2-WIREAC E2E2-WIREAC
3
JPREWIRED SENSORS WITH SHORT-CIRCUIT PROTECTION
Type Size Sensing distance Part number
y
p
g
NO NC
Shielded M18

































5mm E2E-X5Y1-53-US E2E-X5Y2-53-US
M30 10 mm E2E-X10Y1-53-US E2E-X10Y2-53-US
Unshielded M18 10 mm E2E-X10MY1-53-US E2E-X10MY2-53-US
M30
18 mm
E2E-X18MY1-53-US E2E-X18MY2-53-US
JSENSORS WITH BUILT-IN CONNECTORS
Connector Type Size Sensing distance Part number
y
p
g
NO NC
4-pin
connector
Shielded M12


































2mm E2E-X2Y1-M1-N E2E-X2Y2-M1-N
(M12)
SeeNote1. M18


































5mm E2E-X5Y1-M1-N E2E-X5Y2-M1-N
M30 10 mm E2E-X10Y1-M1-N E2E-X10Y2-M1-N
Unshielded M12


































5mm E2E-X5MY1-M1-N E2E-X5MY2-M1-N
M18 10 mm E2E-X10MY1-M1-N E2E-X10MY2-M1-N
M30
18 mm
E2E-X18MY1-M1-N E2E-X18MY2-M1-N
3-pin
connector
(
M
1
2
)
Shielded M12

































2mm E2E-X2Y1-M4 E2E-X2Y2-M4
(M12)
SeeNote2. M18

































5mm E2E-X5Y1-M4 E2E-X5Y2-M4
M30 10 mm E2E-X10Y1-M4 E2E-X10Y2-M4
Unshielded M12

































5mm E2E-X5MY1-M4 E2E-X5MY2-M4
M18 10 mm E2E-X10MY1-M4 E2E-X10MY2-M4
M30
18 mm
E2E-X18MY1-M4 E2E-X18MY2-M4
Note: 1. Use Omron’s Y96E-44jAjconnector cordsets.
2. Use Omron’s Y96E-33jAjconnector cordsets.
JACCESSORIES
Description Part number
Mounting brackets Fits M8 size sensors
Fits M12 size sensors
Fits M18 size sensors
Fits M30 size sensors
Y92E-B8
Y92E-B12
Y92E-B18
Y92E-B30
Silicone rubber covers for shielded sensors Fits M12 size sensors
Fits M18 size sensors
Fits M30 size sensors
Y92E-E12-2
Y92E-E18-2
Y92E-E30-2
Connector cordsets See Y96E Connector Cordsets data sheet for details
E2E2-WIREAC
E2E2-WIREAC
4
JREPLACEMENT PARTS
Description Part number
Mounting hardware including one pair of
metal nuts and one washer
Fits M8 size sensors
Fits M12 size sensors
Fits M18 size sensors
Fits M30 size sensors
M8-MHWS
M12-MHWS
M18-MHWS
M30-MHWS
Specifications
JSENSORS WITHOUT SHORT-CIRCUIT PROTECTION (E2E-Xj
jj
jYj
jj
j)
Part number E2E-X1R5Yj-N E2E-X2MYj-N E2E-X2Yj
-US-N
E2E-X5MY
j-US-N
E2E-X5Y
j-US-N
E2E-X10MY
j-US-N
E2E-X10Y
j-US-N
E2E-X18MY
j-US-N
Size M8 M12 M18 M30
Type Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Sensing distance 1.5 mm
(0.06 in) ±10%
2mm
(0.08 in)
±10%
2mm
(0.08 in)
±10%
5mm
(0.20 in)
±10%
5mm
(0.20 in)
±10%
10 mm
(0.39 in)
±10%
10 mm
(0.39 in)
±10%
18 mm
(0.71 in)
±10%
Supply voltage
(operating voltage
range) (See note 1)
24 to 240 VAC, 50/60 Hz (20 to 264 VAC)
Current consumption 1.7 mA max.
Sensing object Magnetic metals (refer to Engineering Data for non-magnetic metals)
Setting distance 0to1.2mm
(0 to 0.05 in)
0to1.6mm
(0 to 0.06 in)
0to1.6
mm (0 to
0.06 in)
0to4.0
mm (0 to
0.16 in)
0to4.0
mm (0 to
0.16 in)
0to8.0
mm (0 to
0.31 in)
0to8.0
mm (0 to
0.31 in)
0to14.0
mm (0 to
0.55 in)
Standard object
(mild steel)
8x8x1mm
(0.31 x 0.31 x
0.04 in)
12 x 12 x
1 mm (0.47 x
0.47 x 0.04
in)
12 x 12 x
1mm
(0.47 x
0.47 x
0.04 in)
15 x 15 x
1mm
(0.59 x
0.59 x
0.04 in)
18 x 18 x
1mm
(0.71 x
0.71 x
0.04 in)
30 x 30 x
1mm
(1.18 x
1.18 x
0.04 in)
30 x 30 x
1 mm (1.18
x1.18x
0.04 in)
54 x 54 x
1 mm (2.13
x2.13x
0.04 in)
Differential travel 10% max. of sensing distance
Response frequency 25 Hz
Operation (with
sensing object
approaching)
Y1 models: Load ON
Y2 models: Load OFF
Control output
(switching capacity)
5 to 100 mA max. 5 to 200 mA max. 5 to 300 mA max.
Indicator Operation indicator (red LED)
Ambient temperature
(See note 2)
Operating: --25°Cto70°C
(--13°F to 158°F)
with no icing
Operating: --40°Cto85°C(--40°F to 185°F) with no icing
Ambient humidity Operating: 35% to 95%
Temperature
influence
±15% max. of sensing distance at 23°C in temperature range of --40°Cto85°C(--40°F to 185°F)
±10% max. of sensing distance at 23°C in temperature range of --25°Cto70°C(--13°F to 158°F)
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Residual voltage Refer to Engineering Data
Insulation resistance 50 Mmin. (at 500 VDC) between current carry parts and case
Dielectric strength 4,000 VAC for 1 min between current carry parts and case (2,000 VAC for M8 types)
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z directions
Shock resistance 500 m/s2(approx. 50G) for 10
times each in X, Y, and Z axes
1,000 m/s2(approx. 50G) for 10 times each in X, Y, and Z axes
500 m/s2(approx. 50G) for E2E-X5M
Enclosure IEC IP67
rating NEMA 1, 4, 6, 12, 13
Note: 1. When using an M18 or M30 size E2E at an ambient temperature between 70°C and 85°C (158°F and 185°F), make sure that
the E2E has a control output of 200 mA maximum.
2. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is --25°Cto85°C
(--13°F to 185°F).
(This table continues on the next page.)
E2E2-WIREAC E2E2-WIREAC
5
Specifications Table -- continued from previous page
Part number E2E-X1R5Y
j-N
E2E-X2MY
j-N
E2E-X2Yj-
US-N
E2E-X5MYj
-US-N
E2E-X5Yj-
US-N
E2E-X10MY
j-US-N
E2E-X10Y
j-US-N
E2E-X18MY
j-US-N
Approvals UL -- Recognized, File Number E76675
p
p
CSA -- Certified, File Number LR45951
Weight Prewired Approx. 45 g Approx. 120 g Approx. 160 g Approx. 270 g
g
Connector --- Approx. 25 g Approx. 45 g Approx.
125 g
Approx.
124 g
Material Body Stainless steel Brass
Sensing
face
PBT
JSENSORS WITH SHORT-CIRCUIT PROTECTION (E2E-Xj
jj
jYj
jj
j-53-US)
Part number E2E-X5Yj-53-US E2E-X10MYj-53-US E2E-X10Yj-53-US E2E-X18MYj-53-US
Body Size M18 M30
y
Type Shielded Unshielded Shielded Unshielded
Supply voltage 90 to 140 VAC, 50/60 Hz
Effective maximum detecting distance
(with standard target)
5 mm (0.20 in) ±10% 10 mm (0.40 in) ±10% 18 mm
(0.71 in) ±10%
Usable detecting range (with standard
target)
0to4mm
(0 to 0.16 in)
0to8mm(0to0.31in) 0to14mm
(0 to 0.55 in)
Standard target size
(mildsteel,LxWxH)
18x18x1mm
(0.71 x 0.71 x
0.04 in)
30x30x1mm
(1.18 x 1.18 x 0.04 in)
54x54x1mm
(2.13 x 2.13 x
0.04 in)
Differential travel 10% max. of effective detecting distance
Control
output
AC
solid
Type SCR-NO (E2E-XjjjY1-jj-jj)
SCR-NC (E2E-XjjjY2-jj-jj)
p
state Max. load 300 mA
Min. load 5mA
Max. offstate
leakage current
1.5 mA (See “Leakage Current Characteristics graph in Engineering Data.)
Max. on-state
voltage drop
(See Leakage Current Characteristics graph in Engineering Data.)
Response frequency 25 Hz
Circuit Output short-circuit Provided
protection Weld field
immunity
Not provided
RFI immunity Not provided
Indicators Target present (red LED)
Materials Housing Nickel-plated brass
Sensing face Plastic
Cable sheath Plastic
Mounting Two lock washers and M18 nuts included.
Bracket Y92E-B18 optional.
Two lock washers and M30 nuts included.
Bracket Y92E-B30 optional.
Connections Prewired 2-conductor cable, 2 m (6.56 ft) length
Weight with cable Approx. 160 g (5.6 oz.) Approx. 270 g (9.5 oz.)
Enclosure UL 1
ratings NEMA 1, 4, 6, 12, 13
IEC 144 IP67
Approvals UL Recognized, File Number E76675
p
p
CSA Certified, File Number LR45951
Ambient operating temperature -25°to 70°C (-13°to 158°F)
Vibration 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude
Shock Approx. 100 G’s
E2E2-WIREAC
E2E2-WIREAC
6
Operation
JOUTPUT CIRCUITS
Sensors without Short-Circuit Protection (E2E-XjYj)
E2E-XjYj-N AC 2-wire Models
Main
circuit
Load
Brown 1 (or 3)
Blue 2 (or 4)
Sensing
object
Control
output
Yes
No
Lit
Not lit
Red
indicator
ON
OFF
AC 2-wire Models
E2E-XjYj-N
Sensors with Short-Circuit Protection (E2E-XjYj-US-53)
Prox.
switch
main
circuit
White (Brown)
Load
Black (Blue)
Note: IEC colors are shown in parenthesis
With Short-Circuit Protection
E2E-XjY1-53
NO
Load
Target
Output
Output
operation
indicator
Shorted
Normal
Present
Absent
ON
OFF
ON
OFF
Shorted
Normal
Present
Absent
ON
OFF
ON
OFF
E2E-XjY2-53
NC
Short-Circuit Indication
The LED dims when the load is shorted and the load output immediately turns off and remains off until the short-circuit protection is reset.
Resetting Short-Circuit Protection
Before the short-circuit protection can be reset, the short must be repaired. We recommend turning the power off before repairing the
short. If this approach is taken, no further action is required to reset the short-circuit protection.
If the short must be repaired with power on, the following resetting steps are required:
For NO sensors, the target must be removed to reset the short-circuit protection.
For NC sensors, the target must be presented then removed to reset the short-circuit protection.
E2E2-WIREAC E2E2-WIREAC
7
Engineering Data
JOPERATING RANGE (TYPICAL)
Shielded Models
E2E-XjYj-N
Unshielded Models
E2E-XjMYj-N
Y (mm)
Sensing distance
X (mm)
E2Ej-X2j
E2Ej-X1R5j
E2Ej-- X 1 0 j
E2Ej-- X 5 j
Sensing distance
X (mm)
Y (mm)
Sensing distance
X (mm)
Sensing distance
X (mm)
E2Ej-X5Mj
E2Ej-X2MjE2Ej-X10Mj
E2Ej-X18Mj
Y (mm) Y (mm)
JLEAKAGE CURRENT (TYPICAL)
E2E-XjYj-N
Leakage current (mA)
Supply voltage (V)
AC
power
supply
Proximity
Sensor
(when
OFF)
Protective
resistance
E2E-XjYj-53-US
Leakage current (mA)
Supply voltage (V)
E2E2-WIREAC
E2E2-WIREAC
8
JRESIDUAL OUTPUT VOLTAGE (TYPICAL)
E2E-XjYj-N
Load current (mA)
Residual load voltage (V)
Load current (mA) Load current (mA)
Residual output voltage
Residual
load volt-
age
Proximity
Sensor
100 VAC
24 VAC
Residual output voltage
Residual
load volt-
age
Proximity
Sensor
Residual output voltage
Residual
load volt-
age
Proximity
Sensor
200 VAC
Residual load voltage (V)
Residual load voltage (V)
JSENSING DISTANCE VS. SENSING OBJECT (TYPICAL)
E2E-X1R5Yj-N
Sensing distance (mm)
Side length of target d (mm)
Brass
Aluminum
Mild steel
t=1mm
Stainless steel
(SUS304)
E2E-X2Yj-N E2E-X5Yj-N
Sensing distance (mm)
Sensing distance (mm)
Stainless steel
(SUS304)
Brass
Mild steel
Stainless steel
(SUS304)
Brass
Aluminum
t=1mm
t=1mm
Mild steel
Aluminum
Side length of target d (mm) Side length of target d (mm)
E2E-X2MYj-N E2E-X5MYj-N
Sensing distance (mm)
Side length of target d (mm)
Sensing distance (mm)
Mild steel
Stainless steel
(SUS304)
Brass
Aluminum
t=1mm
t=1mm
Brass
Copper
Stainless steel
(SUS304)
Alumi-
num
Mild steel
E2E-X10Yj-N
Sensing distance (mm)
Mild steel
Stainless steel
(SUS304)
Brass
Aluminum
t=1mm
Side length of target d (mm) Side length of target d (mm)
E2E2-WIREAC E2E2-WIREAC
9
JSENSING DISTANCE VS. SENSING OBJECT (TYPICAL) -- CONTINUED
E2E-X10MY-N
Sensing distance (mm)
Side length of target d (mm)
Mild steel
Stainless steel
(SUS304)
Brass
Aluminum
t=1mm
E2E-X18MYj-N
Sensing distance (mm)
Side length of target d (mm)
Mild steel
Stainless steel
(SUS304)
Brass
Aluminum
t=1mm
Models with Short Circuit Protection (E2E-XjYj-53-US)
E2E-X5jj,E2E-X10jj E2E-X10Mjj E2E-X18Mjj
Size of target d [mm (inch)] Size of target d [mm (inch)] Size of target d [mm (inch)]
Sensing distance X [mm (inch)]
Sensing distance X [mm (inch)]
Sensing distance X [mm (inch)]
E2E-X10MIron
E2E2-WIREAC
E2E2-WIREAC
10
Dimensions
JDRAWING LOCATOR
Type Part number Figure number
Prewired without Shielded M8 E2E-X1R5Yj-N 1
short-circuit
p
r
o
t
e
c
t
i
o
n
M12 E2E-X2Yj-N 3
protection M18 E2E-X5Yj-N 5
M30 E2E-X10Yj-N 7
Unshielded M8 E2E-X2MYj-N 2
M12 E2E-X5MYj-N 4
M18 E2E-X10MYj-N 6
M30 E2E-X18MYj-N 8
Prewired with Shielded M18 E2E-X5Yj-53-US 9
short-circuit
p
r
o
t
e
c
t
i
o
n
M30 E2E-X10Yj-53-US 11
protection Unshielded M18 E2E-X10MYj-53-US 10
M30 E2E-X18MYj-53-US 12
4-pin connector Shielded M12 E2E-X2Y-j-M1-N 13
p
(M12) M18 E2E-X5Y1-M1-N 15
M30 E2E-X10Y-j-M1-N 17
Unshielded M12 E2E-X5MY-j-M1-N 14
M18 E2E-X10MY-j-M1-N 16
M30 E2E-X18MY-j-M1-N 18
3-pin MicroChange Shielded M12 E2E-X2Y-j-M4 13
p
g
connector (M12) M18 E2E-X5Y-j-M4 15
M30 E2E-X10Y-j-M4 17
Unshielded M12 E2E-X5MY-j-M4 14
M18 E2E-X10MY-j-M4 16
M30 E2E-X18MY-j-M4 18
E2E2-WIREAC E2E2-WIREAC
11
Unit: mm (inch)
Prewired Models
(Shielded)
Prewired Models
(Unshielded)
Fig.1: E2E-X1R5Yj-N Fig. 2: E2E-X2MYj-N
M8 x 1
Round vinyl-insulated cable
4 dia. (0.08 dia. x 60), 2 cores
Standard length: 2 m
Operation
indicator
Two clamping nut
Toothed washer
M8 x 1
6.1 dia.
Round vinyl-insulated cable
4 dia. (0.08 dia. x 60), 2 cores
Standard length: 2 m
Operation
indicator
Two clamping
nut
Toothed washer
Fig. 3: E2E-X2Yj-N Fig. 4: E2E-X5MYj-N
M12 x 1
Toothed washer
Operation indicator
Round vinyl-insulated cable
4 dia. (0.08 dia. x 60), 2 cores
Standard length: 2 m Toothed washer
Operation
indicator
Round vinyl-insulated cabl
e
4 dia. (0.08 dia. x 60)
2cores
Standard length: 2 m
9dia. M12 x 1
Two clamping nut Two clamping
nut
15 dia. (0.59) 40 (1.57) 15 dia. (0.59) 40 (1.57)
36 (1.42)
6
(0.24)
21 dia. (0.83) 43 (1.69) 21 dia. (0.83) 43 (1.69)
7
(0.28)
36 (1.42)
38 (1.50) 38 (1.50)
Fig. 5: E2E-X5Yj-N Fig. 6: E2E-X10MYj-N
Operation
indicator
Two clamping nut
Toothed washer
M18 x 1 M18 x 1 Operation
indicator
Two clamping nut
Toothed washer
14.8 dia.
Round vinyl-insulated
cable 6 dia. (0.12 dia.
x 45), 2/3 cores
6 dia. (0.08 dia. x 6/17)
robotics cable models
Standard length: 2m
Round vinyl-insulated
Cable 6 dia. (0.12 dia.
x 45), 2/3 cores
6 dia. (0.08 dia. x 6/17)
robotics cable models
Standard length: 2m
43 (1.69)
10
(0.39)
29 dia. (1.14)
29 dia. (1.14) 43 (1.69)
38 (1.50) 38 (1.50)
Fig. 7: E2E-X10Yj-N Fig. 8: E2E-X18MYj-N
M30 x 1.5
Operation indicator
Two clamping nut
Toothed washer
M30 x 1.5
Operation
indicator
Two clamping
nut
Toothed washer
26.8 dia. Round vinyl-insulated
Cable 6 dia. (0.12 dia.
x 45), 2/3 cores
6 dia. (0.08 dia. x 6/17)
robotics cable models
Standard length: 2m
Round vinyl-insulated
Cable 6 dia. (0.12 dia.
x 45), 2/3 cores
6 dia. (0.08 dia. x 6/17)
robotics cable models
Standard len
g
th: 2m
48 (1.89)
43 (1.69)
42 dia. (1.65)
13
(0.51)
48 (1.89)
43 (1.69)
42 dia. (1.65)
E2E2-WIREAC
E2E2-WIREAC
12
JPRE-WIRED MODELS WITH SHORT-CIRCUIT PROTECTION
Fig. 9: E2E-X5Yj-53-US
Unshielded
Fig.10: E2E-X10MYj-53-US
24 (0.945)
across flats
4 (0.16) Indicator
M18
P=1.0
24 (0.945)
across flats
18.5 dia.
(0.728) 29 (1.14)
M18 P=1.0 Indicator
29 (1.14)
40 (1.57)
47 (1.85)
18.5 dia.
(0.728)
10 (0.39)
Cable:
6 (0.24) dia.
2 m (6.56 ft)
Cable:
6 (0.24) dia.
2 m (6.56 ft)
40 (1.57)
47 (1.85)
Shielded
Fig. 11: E2E-X10Yj-53-US Fig. 12 E2E-X18MYj-53-US
Indicator
Cable:
6 (0.24) dia.
2 m (6.56 ft)
30.5 dia
(1.201)
36 (1.417)
across flats
M30 P=1.5
(0.06)
5 (0.20)
30.5 dia
(1.201)
36 (1.417)
across flats
38 (1.50)
50 (1.97)
57 (2.24)
38 (1.50)
50 (1.97)
57 (2.24)
Indicator
13
(0.51)
Cable:
6 (0.24) dia.
2 m (6.56 ft)
Connector Models
(Shielded)
Connector Models
(Unshielded)
Fig. 13: E2E-X2Y1-M1-N Fig. 14: E2E-X5MYj-M1-N
Operation indicator
Two clamping nut
Toothed washer
M12 x 1
M12 x 1
Operation indicator
Two clamping nut
Toothed washer
M12 x 1
M12 x 1
9dia.
53 (2.09)
38 (1.50)
21 dia. (0.83) 53 (2.09)
38 (1.50)
21 dia. (0.83)
7
(0.28)
Fig. 15: E2E-X5Y1-M1-N Fig. 16: E2E-X10MYj-M1-N
Operation indicator
Two clamping nut
Toothed washer
M12 x 1
M18 x 1
M12 x 1
M18 x 1
Operation indicator
Two clamping nut
Toothed washer
14.8 dia.
53 (2.09)
38 (1.50)
29 dia. (1.14) 53 (2.09)
38 (1.50 )
29 dia. (1.14)
10
(0.39)
E2E2-WIREAC E2E2-WIREAC
13
Connector Models
(Shielded), continued
Connector Models
(Unshielded), continued
Fig.17: E2E-X10Y1-M1-N Fig. 18: E2E-X18MYj-M1-N
M30 x 1.5
Operation indicator
Two clamping nut
Toothed washer
M12 x 1
M30 x 1.5
Operation indicator
Two clamping nut
Toothed washer
M12 x 1
26.8 dia.
58 (2.28)
43 (1.69)
42 dia. (1.65) 58 (2.28)
43 (1.69)
42 dia. (1.65)
13
(0.51)
JMOUNTING HOLES
F
Dimensions M8 M12 M18 M30
F (mm) 8.5+0.5/0dia. 12.5+0.5/0dia. 18.5+0.5/0dia. 30.5+0.5/0dia.
Installation
JPIN ARRANGEMENT
E2E-XjYj-M1 AC 2-wire Models
Output
configuration
Applicable models Pin arrangement
NO E2E-XjY1-M1-N
Note: Terminals 1 and 2 are not used.
Load
Load
NC E2E-XjY2-M1-N
Note: Terminals 3 and 4 are not used.
Load
Load
NO, NC E2E-XjYj-M4
E2E2-WIREAC
E2E2-WIREAC
14
Precautions
JMOUNTING
Do not tighten the nut with excessive force. A washer must be used
with the nut.
Shielded Model Unshielded Model
Part B Part A Part B Part A
Note: The table above right shows the tightening torques for part
A and part B nuts. In the previous examples, the nut is on
the sensor head side (part B) and hence the tightening
torque for part B applies. If this nut is in part A, the tightening
torque for part A applies instead.
Type Part A Part B
y
p
Length Torque Torque
M8 Shielded 9mm 9NSm
(
9
0
k
g
f
S
12 N Sm
(
1
2
0
k
g
f
S
Unshielded 3mm (90 kgf S
cm)
(120 kgf S
cm)
M12 30 N Sm (310 kgf Scm)
M18 70 N Sm (710 kgf Scm)
M30 180 N Sm (1,800 kgf Scm)
JEFFECTS OF SURROUNDING METAL
When mounting the E2E within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these
distances may cause deterioration in the performance of the sensor.
ddia.
Type Dimension M8 M12 M18 M30
E2E-XjYj-N Shielded 0mm 0mm 0mm 0mm
j
j
AC 2-wire d8mm 12 mm 18 mm 30 mm
D0mm 0mm 0mm 0mm
m4.5 mm 8mm 20 mm 40 mm
n12 mm 18 mm 27 mm 45 mm
Unshielded 6mm 15 mm 22 mm 30 mm
d24 mm 40 mm 55 mm 90 mm
D6mm 15 mm 22 mm 30 mm
m8mm 20 mm 40 mm 70 mm
n24 mm 36 mm 54 mm 90 mm
E2E2-WIREAC E2E2-WIREAC
15
JMUTUAL INTERFERENCE
When installing two or more Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are main-
tained.
AB
Type Dimension M8 M12 M18 M30
E2E-XjYj-N Shielded A20 mm 30 (20) mm 50 (30) mm 100 (50) mm
j
j
AC 2-wire B15 mm 20 (12) mm 35 (18) mm 70 (35) mm
Unshielded A80 mm 120 (60) mm 200 (100) mm 300 (100) mm
B60 mm 100 (50) mm 110 (60) mm 200 (100) mm
Note: The figures in parentheses refer to Sensors operating at different frequencies.
JINSTALLATION
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power
is supplied. If power supplies are connected to the Proximity Sensor
and load respectively, be sure to supply power to the Proximity Sen-
sor before supplying power to the load.
Power OFF
The Proximity Sensor may output a pulse signal when it is turned off.
Therefore, it is recommended to turn off the load before turning off
the Proximity Sensor.
Power Supply Transformer
When using a DC power supply, make sure that the DC power sup-
ply has an insulated transformer. Do not use a DC power supply with
an auto-transformer.
Sensing Target
Metal Coating:
The sensing distances of the Proximity Sensor vary with the metal
coating on sensing targets.
JWIRING
High-tension Lines
Wiring through Metal Conduit
If there is a power or high-tension line near the cord of the Proximity
Sensor, wire the cord through an independent metal conduit to pre-
vent against Proximity Sensor damage or malfunctioning.
Cable Tractive Force
Do not pull cable with the tractive forces exceeding the following.
Diameter Tractive force
4mmdia.max. 30 N max.
4 mm dia. min. 50 N max.
JMOUNTING
The Proximity Sensor must not be subjected to excessive shock
with a hammer when it is installed, or the Proximity Sensor may be
damaged or lose its water-resistance.
JENVIRONMENT
Water Resistance
Do not use the Proximity Sensor underwater, outdoors, or in the
rain.
Operating Environment
Be sure to use the Proximity Sensor within its operating ambient
temperature range and do not use the Proximity Sensor outdoors to
maintain its reliability and life expectancy. Although the Proximity
Sensor is water resistant, a cover to protect the Proximity Sensor
from water or water soluble machining oil is recommended so that
its reliability and life expectancy can be maintained.
Do not use the Proximity Sensor in an environment with chemical
gas (e.g., strong alkaline or acid gasses including nitric, chromic,
and concentrated sulfuric acid gases).
E2E2-WIREAC
E2E2-WIREAC
16
JCONNECTING LOAD TO AC 2-WIRE
SENSOR
Refer to the following before using AC or DC 2-wire Proximity Sen-
sors.
Surge Protection
Although the Proximity Sensor has a surge absorption circuit, if
there is any machine that has a large surge current (e.g., a motor or
welding machine) near the Proximity Sensor, connect a surge ab-
sorber to the machine.
Leakage Current
When it is OFF, the Proximity Sensor has leakage current. Refer to
Leakage Current Characteristics. In this case, the load is imposed
with a small voltage and the load may not be reset. Before using the
Proximity Sensor, make sure that this voltage is less than the load
reset voltage. The AC 2-wire Proximity Sensor cannot be con-
nected to any card-lift-off relay (e.g., the G2A) because contact
vibration of the relay will be caused by the leakage current and the
life of the relay will be shortened.
Countermeasures Against Leakage Current
AC 2-wire Models
Connect a bleeder resistor as the bypass for the leakage current so
that the current flowing into the load will be less than the load reset
current.
As shown in the following diagram, connect the bleeder resistor so
that the current flowing into the Proximity Sensor will be 10 mA mini-
mum and the residual voltage imposed on the load will be less than
the load reset voltage.
Load
Bleeder resistor R
VAC power
supply VS
Refer to the following to calculate the bleeder resistance and the al-
lowable power of the bleeder resistor.
RVS/(10 -- I) (k)
P>V
S2/R (mW)
P: The allowable power of the bleeder resistor. (The actual power
capacity of the bleeder resistor must be at least a few times as
large as the allowable power of the bleeder resistor.)
I: Load current (mA)
The following resistors are recommended.
100 VAC (supply voltage): A resistor with a resistance of 10 kmax-
imum and an allowable power of 3 W minimum
200 VAC (supply voltage): A resistor with a resistance of 20 kmax-
imum and an allowable power of 10 W minimum
If these resistors generate excessive heat, use a resistor with a re-
sistanceof10kmaximum and an allowable power of 5 W mini-
mum at 100 VAC and a resistor with a resistance of 20 kmaximum
and an allowable power of 10 W minimum at 200 VAC instead.
JPRECAUTIONS FOR AC 2-WIRE PROXIMITY SENSORS IN OPERATION
Connector
Model Connection type Method Description
AC
2-wire
AND
(serial connection) Load
Load
Load
Vs100 V
Incorrect
Correct
If 100 or 200 VAC is imposed on the Proximity
Sensors, VL(i.e., the voltage imposed on the
load) will be obtained from the following.
VL=V
S-- (residual voltage x no. of Proximity
Sensors) (V)
Therefore, if VLis lower than the load operating
voltage, the load will not operate.
A maximum of three Proximity Sensors can be
connected in series provided that the supply
voltage is 100 V minimum.
E2E2-WIREAC E2E2-WIREAC
JPRECAUTIONS FOR AC 2-WIRE PROXIMITY SENSORS IN OPERATION, CONTINUED
Model Connection type Method Description
AC
2-wire
OR
(parallel connection)
Load
Load
VAC power
supply VS
AB
A
B
Incorrect
Correct
In principle, more than two Proximity Sensors
cannot be connected in parallel.
Provided that Proximity Sensor A does not
operate with Proximity Sensor B simultaneously
and there is no need to keep the load operating
continuously, the Proximity Sensors can be
connected in parallel. In this case, however, due
to the total leakage current of the Proximity
Sensors, the load may not reset properly.
It is not possible to keep the load operating
continuously with Proximity Sensors A and B in
simultaneous operation to sense sensing objects
due to the following reason.
When Proximity Sensor A is ON, the voltage
imposed on Proximity Sensor A will drop to
approximately 10 V and the load current flows
into Proximity Sensor A, and when one of the
sensing objects is close to Proximity Sensor B,
Proximity Sensor B will not operate because the
voltage imposed on Proximity Sensor B is 10 V,
which is too low. When Proximity Sensor A is
OFF, the voltage imposed on Proximity Sensor B
will reach the supply voltage and Proximity
Sensor B will be ON. Then, Proximity Sensor A
as well as Proximity Sensor B will be OFF for
approximately 10 ms, which resets the load for
an instant. To prevent the instantaneous
resetting of the load, use a relay as shown on the
left.
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A.
OMRONELECTRONICSLLC
One EastCommerceDrive
Schaumburg, IL 60173
NOTE:DIMENSIONS SHOWN AREINMILLIMETERS.To convertmillimeterstoinches divideby 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 MilnerAvenue
Scarborough,OntarioM1B5V8
416-286-6465
R
OMRONON--LINE
Global-- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci