CUS SERIES - 1 WATT Rev. 08/2000 FEATURES DESCRIPTION * Industry Standard CUS non-regulated DC/DC converters offer short circuit Package protection and 500 VDC isolation in an industry standard DIP package. Available in 5 or 12 Volt input versions, the * Industry Standard Pinout CUS is ideal for industrial and EDP applications. Please see * 85C Case Operation the CUD series for dual output applications. * Short Circuit Protection Selection Chart CUS509 Input Range VDC 4.65 - 5.50 9 0.150 CUS512 4.65 - 5.50 12 0.125 Model 1.25" (31.8mm) Output VDC Output Current CUS515 4.65 - 5.50 15 0.100 CUS1205 10.80 - 13.20 5 0.220 CUS1209 10.80 - 13.20 9 0.150 CUS1212 10.80 - 13.20 12 0.125 CUS1215 10.80 - 13.20 15 0.100 0.40" (10.2mm) Note: For model options, see the last page of this file. 1 * 5V and 12V Inputs * Input Pi Filter * Low Profile DIP Package * 500V Isolation 0.80" (20.3mm) OPTIONS When ordering equipment options, use the following suffix information. Select the option(s) that you prefer and add them to the model number. Example ordering options are located below the options table. OPTION SUFFIX APPLICABLE SERIES Negative Logic N HAS, HBD, HBS, HES, HLS, HLD, LES, QBS, QES, QLS, TES, TQD Lucent-Compatible Trim T HAS, HBD, HBS, HES, HLS, QBS, QES, QLS Terminal Strip TS XWS, XWD, XWT Trim 1 IAS, LES Enable 2 IAD, IAS, LES, SMS Trim and Enable 3 IAS, LES 0.110" (2.8mm) Pin Length 8 All Leaded Models 0.150" (3.8mm) Pin Length 9 All Leaded Models Pin Length and Heatsink Options REMARKS TTL "Low" Turns Module ON TTL "High" Turns Module OFF Standard Pin Length is 0.180" (4.6mm) 0.24" (6.1mm) Horizontal Heatsink 1H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.24" (6.1mm) Vertical Heatsink 1V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.45" (11.4mm) Horizontal Heatsink 2H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.45" (11.4mm) Vertical Heatsink 2V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.95" (24.1mm) Horizontal Heatsink 3H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.95" (24.1mm) Vertical Heatsink 3V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad Example Options: HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95" vertical heatsink. LES015YJ-3N = LES015YJ with optional trim and enable, negative logic. QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110" pin length. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional President of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. REV. AUG 16, 2002 2