AC-DC
Specification
50-150 Watts
•AC Input LED Driver
•Constant Voltage & Current Operation
•High Power Factor
•High Efficiency
•Water Proof to IP67
•90-305 VAC Input Voltage Range
•3 Year Warranty
DLG Series
Input
Input Voltage • 90-305 VAC, see derating curve
Input Frequency • 47-63 Hz
Input Current • 50 W: 1.0 A at 115 VAC, 0.5 A at 230 VAC,
75 W: 1.2 A at 115 VAC, 0.6 A at 230 VAC,
100 W: 1.4 A at 115 VAC, 0.7 A at 230 VAC,
150 W: 2.0 A at 115 VAC, 1.0 A at 230 VAC
Inrush Current • 65 A at 230 VAC, cold start +25 °C
Power Factor • >0.94 at 230 VAC, full load
Earth Leakage Current • DLG50/75: 500 µA max at 230 VAC
DLG100/150: 750 µA max at 230 VAC
No Load Input Power • DLG100: 0.5 W max at 230 VAC
Other models: 0.6 W max at 230 VAC
Input Protection • DLG50/75 T2.5A/300V fuse fitted in line,
DLG100 T3.15A/300V fuse fitted in line,
DLG150 T4A/300V fuse fitted in line
Output
Output Voltage • See table
Minimum Load • No minimum load required
Start Up Delay • 1.5 s max at 115 VAC
Hold Up Time • DLG50/75: No hold up
DLG100/150: 16 ms minimum
Line Regulation • ±0.5%
Load Regulation • ±1.0% in constant voltage mode,
±5.0% in constant current mode
Turn On Overshoot • 5% max
Transient Response • 5% maximum deviation, recovery to within
1% in 10 ms for a 50% load change
Ripple & Noise • DLG50/75(1)
DLG100/150: 150 mV pk-pk up to 36 V
output, 200 mV for 48 V output, 240 mV
for ≥54 V output (see note 2)
Overvoltage Protection • 110-142%, recycle mains to reset, only on
DLG100 & DLG150 versions
Overtemperature • Unit shuts down, recycle mains to reset
Protection
Overload Protection • 105% maximum, auto recovery
Short Circuit Protection • Trip and restart (hiccup mode)
Temp. Coefficient • 0.04%/°C
xppower.com
General
Efficiency • See table
Isolation • 3750 VAC Input to Output
1880 VAC Input to Ground
500 VAC Output to Ground
Switching Frequency • DLG50/75: 40-80 kHz
DLG100/150: PWM 60-80 kHz,
PFC 55-133 kHz
MTBF • >200 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • DLG50/75: -40 °C to +60 °C
(see derating curve),
DLG100/150: -30 °C to +70 °C
(see derating curve)
Operating Humidity • 5-100% RH, non-condensing
Storage Temperature • -40 °C to +80 °C
Operating Altitude • 3000 m
Vibration • 10-500 Hz, 2 g, 10 mins/cycle, 6 cycles in
each of 3 axes
EMC & Safety
Emissions • EN55015, class B conducted and radiated
Harmonic Currents • EN61000-3-2, class A
EN61000-3-2, class C for loads >80%
Voltage Flicker • EN61000-3-3
ESD Immunity • EN61000-4-2, 8 kV air and 4 kV contact,
Perf Criteria A
Radiated Immunity • EN61000-4-3, level 2 Perf Criteria A
EFT/Burst • EN61000-4-4, level 2 Perf Criteria A
Surge • EN61000-4-5, installation class 3,
Perf Criteria A
Conducted Immunity • EN61000-4-6, level 2 Perf Criteria A
Dips & Interruptions • EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
Safety Approvals • EN61347, UL8750, CE Mark
Notes
1. DLG50/75 use a topology which results in increased levels of mains frequency
related ripple. Contact technical sales for details.