AC-DC
Specification
50-150 Watts
AC Input LED Driver
Constant Voltage & Current Operation
High Power Factor
High Efficiency
Water Proof to IP67
90-305 VAC Input Voltage Range
3 Year Warranty
DLG Series
Input
Input Voltage 90-305 VAC, see derating curve
Input Frequency 47-63 Hz
Input Current 50 W: 1.0 A at 115 VAC, 0.5 A at 230 VAC,
75 W: 1.2 A at 115 VAC, 0.6 A at 230 VAC,
100 W: 1.4 A at 115 VAC, 0.7 A at 230 VAC,
150 W: 2.0 A at 115 VAC, 1.0 A at 230 VAC
Inrush Current 65 A at 230 VAC, cold start +25 °C
Power Factor >0.94 at 230 VAC, full load
Earth Leakage Current DLG50/75: 500 µA max at 230 VAC
DLG100/150: 750 µA max at 230 VAC
No Load Input Power DLG100: 0.5 W max at 230 VAC
Other models: 0.6 W max at 230 VAC
Input Protection DLG50/75 T2.5A/300V fuse fitted in line,
DLG100 T3.15A/300V fuse fitted in line,
DLG150 T4A/300V fuse fitted in line
Output
Output Voltage See table
Minimum Load No minimum load required
Start Up Delay 1.5 s max at 115 VAC
Hold Up Time DLG50/75: No hold up
DLG100/150: 16 ms minimum
Line Regulation ±0.5%
Load Regulation ±1.0% in constant voltage mode,
±5.0% in constant current mode
Turn On Overshoot 5% max
Transient Response 5% maximum deviation, recovery to within
1% in 10 ms for a 50% load change
Ripple & Noise DLG50/75(1)
DLG100/150: 150 mV pk-pk up to 36 V
output, 200 mV for 48 V output, 240 mV
for ≥54 V output (see note 2)
Overvoltage Protection 110-142%, recycle mains to reset, only on
DLG100 & DLG150 versions
Overtemperature Unit shuts down, recycle mains to reset
Protection
Overload Protection 105% maximum, auto recovery
Short Circuit Protection Trip and restart (hiccup mode)
Temp. Coefficient 0.04%/°C
xppower.com
General
Efficiency See table
Isolation 3750 VAC Input to Output
1880 VAC Input to Ground
500 VAC Output to Ground
Switching Frequency DLG50/75: 40-80 kHz
DLG100/150: PWM 60-80 kHz,
PFC 55-133 kHz
MTBF >200 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature DLG50/75: -40 °C to +60 °C
(see derating curve),
DLG100/150: -30 °C to +70 °C
(see derating curve)
Operating Humidity 5-100% RH, non-condensing
Storage Temperature -40 °C to +80 °C
Operating Altitude 3000 m
Vibration 10-500 Hz, 2 g, 10 mins/cycle, 6 cycles in
each of 3 axes
EMC & Safety
Emissions EN55015, class B conducted and radiated
Harmonic Currents EN61000-3-2, class A
EN61000-3-2, class C for loads >80%
Voltage Flicker EN61000-3-3
ESD Immunity EN61000-4-2, 8 kV air and 4 kV contact,
Perf Criteria A
Radiated Immunity EN61000-4-3, level 2 Perf Criteria A
EFT/Burst EN61000-4-4, level 2 Perf Criteria A
Surge EN61000-4-5, installation class 3,
Perf Criteria A
Conducted Immunity EN61000-4-6, level 2 Perf Criteria A
Dips & Interruptions EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
Safety Approvals EN61347, UL8750, CE Mark
Notes
1. DLG50/75 use a topology which results in increased levels of mains frequency
related ripple. Contact technical sales for details.
0 10 20 30 40 50 55 60 70
20
40
60
80
100
0
-30 for DLG100/150
-40 for DLG50/75
Ambient Temp (˚C)
Load (%)
100 115 130 180 220 240 30590
20
40
60
80
100
0
Input Voltage (VAC) 60Hz
Ta= 25˚C
Load (%)
B
B
C
A
A
B
DLG150 at 115 VAC
DLG150 at 230 VAC & DLG100
CDLG50/75 DLG100
DLG150
B
DLG50/75
A
C
A
C
27 Sept 16
AC-DC
DLG50-150
Models and Ratings
Notes
Notes
1. Typical efficiency at full load and 230 VAC input.
2. Measured using 12” twisted pair with 0.1 µF and 47 µF capacitors in parallel
at 20 MHz bandwidth.
3. Not UL8750 approved.
1.54 (39.0)
A
C2.68 (68.0)
4-R2.1
B
11.81±0.79 (300±20) 11.81±0.79 (300±20)
AC IN DC OUT
18AWGx3C 18 AWGx2C (DLG50/75/100-
see note 4 below)
ACL
ACN
V+ (RED)
V- (BLACK)
0.35
(8.9)
0.35 (8.9)
1.35 (34.2)
0.28 (7.0)
14 AWGx2C (DLG150)
Mechanical Details
Derating Curve
Constant Voltage / Constant Current Curve
Application Notes
10010 20 30 40 50 60 70 80 90
Vo max
Vo min
0
Output Current (%)
Output Voltage
Trip & Restart Zone
Output Power Output Voltage Output Current
Output Voltage
Range in Constant
Current Mode
Efficiency(1) Model Number
50 W 12.0 V 4.20 A 8.5-12.0 V 84.0% DLG50PS12
50 W 24.0 V 2.10 A 19.0-24.0 V 86.0% DLG50PS24
50 W 36.0 V 1.40 A 26.0-36.0 V 88.0% DLG50PS36
50 W 48.0 V 1.05 A 35.0-48.0 V 88.0% DLG50PS48
59 W 12.0 V 4.90 A 8.5-12.0 V 84.0% DLG75PS12
75 W 24.0 V 3.15 A 19.0-24.0 V 86.0% DLG75PS24
74 W 30.0 V 2.45 A 22.0-30.0 V 87.0% DLG75PS30
75 W 36.0 V 2.10 A 26.0-36.0 V 88.0% DLG75PS36
67 W 48.0 V 1.40 A 35.0-48.0 V 88.0% DLG75PS48
75 W 54.0 V 1.40 A 37.0-54.0 V 88.0% DLG75PS54
100 W 12.0 V 8.30 A 9.0-12.0 V 88.0% DLG100PS12
100 W 15.0 V 6.60 A 10.0-15.0 V 88.0% DLG100PS15(3)
100 W 24.0 V 4.20 A 14.0-24.0 V 90.0% DLG100PS24
100 W 30.0 V 3.30 A 22.0-30.0 V 90.0% DLG100PS30
100 W 36.0 V 2.80 A 26.0-36.0 V 90.0% DLG100PS36
100 W 48.0 V 2.10 A 34.0-48.0 V 90.5% DLG100PS48
100 W 57.0 V 1.75 A 43.0-57.0 V 90.5% DLG100PS57(3)
132 W 12.0 V 11.00 A 9.0-12.0 V 88.0% DLG150PS12
150 W 15.0 V 10.00 A 11.0-15.0 V 88.0% DLG150PS15(3)
150 W 24.0 V 6.30 A 14.0-24.0 V 90.0% DLG150PS24
150 W 30.0 V 5.00 A 22.0-30.0 V 90.0% DLG150PS30
150 W 36.0 V 4.20 A 26.0-36.0 V 90.0% DLG150PS36
150 W 48.0 V 3.20 A 33.0-48.0 V 90.0% DLG150PS48
150 W 54.0 V 2.80 A 38.0-54.0 V 90.0% DLG150PS54(3)
1. All dimensions shown in inches (mm).
2. Weight: DLG50/75: 1.98 lbs (900 g)
DLG100/150 2.29 lbs (1040 g)
3. Tolerance: ±0.02 (0.5)
4. DLG100PS12 and DLG100PS15 output
cable is 14 AWG.
DLG50/75 DLG100/150
A 6.93 (176.0) 8.74 (222.0)
B 6.38 (162.0) 8.19 (208.0)
C 6.03 (153.2) 7.83 (199.0)