Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8219 Coax - RG-58A/U Type For more Information please call 1-800-Belden1 General Description: RG-58A/U type, 20 AWG stranded (19x32) .037" tinned copper conductor, foam polyethylene insulation, tinned copper braid shield (95% coverage), PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Coax AWG Stranding Conductor Material Dia. (mm) 1 20 19x32 TC - Tinned Copper 0.9398 Total Number of Conductors: 1 Insulation Insulation Material: Insulation Material Dia. (mm) FPE - Foam Polyethylene 2.8956 Outer Shield Outer Shield Material: Type Outer Shield Material Coverage (%) Braid TC - Tinned Copper 95.000 Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Overall Cable Overall Nominal Diameter: 4.902 mm Mechanical Characteristics (Overall) Operating Temperature Range: -40C To +80C UL Temperature Rating: 80C Bulk Cable Weight: 37.205 Kg/Km Max. Recommended Pulling Tension: 222.410 N Min. Bend Radius/Minor Axis: 50.800 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM CEC/C(UL) Specification: CM AWM Specification: UL Style 1354 EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8219 Coax - RG-58A/U Type EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes PMSHA Specification: SC-182/5 RG Type: 58A/U Flame Test UL Flame Test: UL1685 UL Loading Suitability Suitability - Indoor: Yes Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 54 Nom. Inductance: Inductance (H/m) 0.213265 Nom. Capacitance Conductor to Shield: Capacitance (pF/m) 86.9465 Nominal Velocity of Propagation: VP (%) 73 Nominal Delay: Delay (ns/m) 4.56059 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 28.8728 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 13.4521 Nom. Attenuation: Freq. (MHz) Attenuation (dB/100m) 1 1.3124 10 4.2653 50 10.1711 100 14.7645 200 21.6546 400 32.81 700 46.5902 900 54.4646 1000 59.3861 Max. Operating Voltage - UL: Voltage 30 V RMS (UL AWM Style 1354) 300 V RMS (CM) Page 2 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8219 Coax - RG-58A/U Type Other Electrical Characteristic 1: Actual Impedance specification is 53.5 +/- 3 ohms. Put Ups and Colors: Item # Putup Ship Weight Color 8219 009U500 152 MT 6.350 KG WHITE Notes Item Desc 8219 0091000 305 MT 12.701 KG WHITE 8219 010U1000 305 MT 12.247 KG BLACK 8219 010U500 152 MT 6.350 KG BLACK 8219 0101000 305 MT 12.701 KG BLACK C RG58A/U TYPE COAX 8219 010500 152 MT 6.577 KG BLACK C RG58A/U TYPE COAX RG58A/U TYPE COAX C RG58A/U TYPE COAX RG58A/U TYPE COAX RG58A/U TYPE COAX Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 07-30-2013 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013