Thermistor Temperature Simple Logger (R) Model L605 Specifications ELECTRICAL Number of Channels: 1 Measurement Range: Temperature F & C Input Connection: In-line Connector Resolution: 8 Bit (see chart on page 19) Accuracy*: 1% of Reading 0.25C (see inside back cover for details) Sample Rate: 4096/hr max, decreases by 50% each time memory is full Storage Technique: Time Extension RecordingTM (TXRTM) Data Storage: 8192 readings Power: 9V Alkaline battery Battery Life: Up to 1 yr of recording @ 25C Output: RS-232 via DB-9 connector Indicators: Red LED double flashes in LOGGING, single flashes in STANDBY, and is off in OFF mode Controls: One button used to start and stop recording sessions and to turn the data logger on and off MECHANICAL Size: 2 7/8 x 2 5/16 x 15/8" (73 x 59 x 41mm) Weight: (with battery) 5 oz (140g) Mounting: Base plate mounting holes or Velcro(R) pads ENVIRONMENTAL Operating Temperature: -4 to +158F (-20 to +70C) Storage Temperature: -4 to +174F (-20 to +80C) Relative Humidity: 5 to 95% non-condensing Safety: EN 61010, 30V, Cat. III Features Applications * Internal or External Thermistor * Thermistor type 10K @ 25C * Measurement Range: (Internal) -4 to +158F (-20 to +70C) (External) -4 to +212F (-20 to +100C) * * * * * * * Ambient temperature monitoring HVAC troubleshooting Computer room monitoring Food storage Wave soldering temperature profiling Process control monitoring Refrigerated freight * Double Insulation * CE Mark ORDERING INFORMATION CATALOG NO. Simple Logger Model L605, Temperature (Temperature - Internal/External Thermistor) . . . . . . . . . . . . . . . . . . . . Cat. #2114.17 (Optional thermistor temperature probes listed below) (R) Includes supplied with software (CD-ROM), 6 ft DB-9 RS-232 serial cable, 9V Alkaline battery and user manual Accessories Thermistor Probe with Epoxy bead, 6 ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat. #2114.19 Thermistor Probe with 4" Stainless Steel Sheath, 6 ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat. #2114.20 Thermistor Temperature Simple Logger(R) Model L605 (pdf) Rev. 02 121/05 Technical Assistance (800) 343-1391 www.aemc.com 1 of 5 Simple Logger (R) Software Features Computer Requirements * Very easy to setup and use -- no programming required * Print both graphs and tabular listings * Statistics appear on screen: Max, Min, Avg, Date and Time * Paste graphs into other applications * 486 or higher * 8MB of RAM * Windows(R) 95/98/2000/ME/XP or Windows (R)NT * On-Line display of data logger values * Programmable scale and units for all DC loggers. Automatic selection for AC loggers * 1 serial port not in use by any other device * Zoom capability with automatic statistics update * User programmable High and Low limits (Model L215) * 8MB hard drive space for program and 400kB max per file stored * User keyed text annotations * User programmable record modes - inside or outside of limits (Model L215) * Automatically displays values at the cursor position * Export data to spreadsheet and database software * Automatic baud rate selection (version 6.0 or later) Plot graphs and view statistics quickly and easily when you download data from Simple Logger (R) to your computer. Scale and time axis update automatically. Click and drag your mouse to zoom up the desired area of the graph for better viewing. The Min, Max and Average statistics at the bottom of the graph update automatically with zoom window. Click the Annotate button to add a title and descriptive information to your graph. This information can be stored and printed with a graph. Thermistor Temperature Simple Logger(R) Model L605 (pdf) Rev. 02 121/05 Technical Assistance (800) 343-1391 www.aemc.com 2 of 5 On-line display of data Automatic update of Y data at cursor position Annotate button Plot area with value and time data shown on the X and Y axis Graph Statistics Click the Annotate button to add a title and descriptive information to your graph. This information can be stored and printed with a graph. Thermistor Temperature Simple Logger(R) Model L605 (pdf) Rev. 02 121/05 Technical Assistance (800) 343-1391 www.aemc.com 3 of 5 Simple Logger (R) Software Click the scale button in the file menu to create custom scales and engineering units for DC voltage (Models L410 & L430) and DC current loggers (Model L320). Click and drag your mouse to zoom up the desired area of the graph for better viewing. The Min, Max and Average statistics at the bottom of the graph update automatically when the graph is zoomed. Thermistor Temperature Simple Logger(R) Model L605 (pdf) Rev. 02 121/05 Technical Assistance (800) 343-1391 www.aemc.com 4 of 5 Contact Us United States & Canada: Chauvin Arnoux(R), Inc. d.b.a. AEMC (R) Instruments 200 Foxborough Blvd. Foxborough, MA 02035 USA (508) 698-2115 * Fax (508) 698-2118 www.aemc.com Customer Support - for placing an order, obtaining price & delivery: customerservice@aemc.com Sales Department - for general sales information: sales@aemc.com Repair and Calibration Service - for information on repair & calibration, obtaining a user manual: repair@aemc.com Technical and Product Application Support - for technical and application support: techinfo@aemc.com Webmaster - for information regarding www.aemc.com: webmaster@aemc.com South America, Central America, Mexico, Caribbean, Australia & New Zealand: Chauvin Arnoux(R), Inc. d.b.a. AEMC (R) Instruments 15 Faraday Drive Dover, NH 03820 USA (978) 526-7667 * Fax (978) 526-7605 export@aemc.com www.aemc.com All other countries: Chauvin Arnoux SCA 190, rue Championnet 75876 Paris Cedex 18, France 33 1 44 85 45 28 * Fax 33 1 46 27 73 89 info@chauvin-arnoux.com www.chauvin-arnoux.com Thermistor Temperature Simple Logger(R) Model L605 (pdf) Rev. 02 121/05 Technical Assistance (800) 343-1391 www.aemc.com 5 of 5