Thermistor Temperature Simple Logger®Model L605 (pdf) Rev. 02 121/05
Technical Assistance (800) 343-1391 www.aemc.com
1
of 5
Thermistor Temperature Simple Logger®
Model L605
ORDERING INFORMATION CATALOG NO.
Simple Logger®Model L605, Temperature (Temperature Internal/External Thermistor) . . . . . . . . . . . . . . . . . . . . Cat. #2114.17
(Optional thermistor temperature probes listed below)
Includes supplied with software (CD-ROM), 6 ft DB-9 RS-232 serial cable, 9V Alkaline battery and user manual
Accessories
Thermistor Probe with Epoxy bead, 6 ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat. #2114.19
Thermistor Probe with 4" Stainless Steel Sheath, 6 ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cat. #2114.20
Features
Internal or External Thermistor
Thermistor type 10KΩ@ 25°C
Measurement Range:
(Internal)
-4 to +158°F (-20 to +70°C)
(External)
-4 to +212°F (-20 to +100°C)
Double Insulation
CE Mark
Applications
Ambient temperature monitoring
HVAC troubleshooting
Computer room monitoring
Food storage
Wave soldering temperature profiling
Process control monitoring
Refrigerated freight
Specifications
ELECTRICAL
Number of Channels: 1
Measurement Range:
Temperature °F & °C
Input Connection:
In-line Connector
Resolution: 8 Bit (see chart on page 19)
Accuracy*: ±1% of Reading ± 0.25˚C
(see inside back cover for details)
Sample Rate: 4096/hr max, decreases
by 50% each time memory is full
Storage Technique:
Time Extension Recording™ (TXR™)
Data Storage: 8192 readings
Power: 9V Alkaline battery
Battery Life:
Up to 1 yr of recording @ 25°C
Output: RS-232 via DB-9 connector
Indicators: Red LED double flashes in
LOGGING, single flashes in STANDBY,
and is off in OFF mode
Controls: One button used to start and
stop recording sessions and to turn the
data logger on and off
MECHANICAL
Size: 27/8x 25/16 x 15/8"
(73 x 59 x 41mm)
Weight: (with battery) 5 oz (140g)
Mounting:
Base plate mounting holes or
Velcro®pads
ENVIRONMENTAL
Operating Temperature:
-4 to +158°F (-20 to +70°C)
Storage Temperature:
-4 to +174°F (-20 to +80°C)
Relative Humidity:
5 to 95% non-condensing
Safety: EN 61010, 30V, Cat. III
Thermistor Temperature Simple Logger®Model L605 (pdf) Rev. 02 121/05
Technical Assistance (800) 343-1391 www.aemc.com
2
of 5
Simple Logger®Software
Features
Very easy to setup and use —
no programming required
Statistics appear on
screen: Max, Min, Avg,
Date and Time
On-Line display of data
logger values
Zoom capability with automatic
statistics update
User keyed text annotations
Automatically displays values
at the cursor position
Export data to spreadsheet
and database software
Print both graphs and
tabular listings
Paste graphs into other
applications
Programmable scale and units
for all DC loggers. Automatic
selection for AC loggers
User programmable High and
Low limits (Model L215)
User programmable record
modes – inside or outside of
limits (Model L215)
Automatic baud rate selection
(version 6.0 or later)
Computer
Requirements
486 or higher
8MB of RAM
Windows®95/98/2000/ME/XP
or Windows®NT
1 serial port not in use by
any other device
8MB hard drive space for
program and 400kB max
per file stored
Plot graphs and view statistics quickly and easily when you download
data from Simple Logger ®to your computer. Scale and time axis
update automatically.
Click and drag your mouse to zoom up the desired area of the graph
for better viewing. The Min, Max and Average statistics at the bottom
of the graph update automatically with zoom window.
Click the Annotate button to add a title and descriptive information to
your graph. This information can be stored and printed with a graph.
Thermistor Temperature Simple Logger®Model L605 (pdf) Rev. 02 121/05
Technical Assistance (800) 343-1391 www.aemc.com
3
of 5
Plot area with value and time data
shown on the X and Y axis
Click the Annotate button to add a title and descriptive
information to your graph. This information can be stored
and printed with a graph.
On-line display of data
Annotate
button
Automatic update
of Y data at
cursor position
Graph
Statistics
Thermistor Temperature Simple Logger®Model L605 (pdf) Rev. 02 121/05
Technical Assistance (800) 343-1391 www.aemc.com
4
of 5
Simple Logger®Software
Click and drag your mouse to zoom up the desired
area of the graph for better viewing. The Min, Max
and Average statistics at the bottom of the graph
update automatically when the graph is zoomed.
Click the scale button in the file menu to
create custom scales and engineering units
for DC voltage (Models L410 & L430)
and DC current loggers (Model L320).
Thermistor Temperature Simple Logger®Model L605 (pdf) Rev. 02 121/05
Technical Assistance (800) 343-1391 www.aemc.com
5
of 5
Contact Us
United States & Canada:
Chauvin Arnoux®, Inc.
d.b.a. AEMC®Instruments
200 Foxborough Blvd.
Foxborough, MA 02035 USA
(508) 698-2115 • Fax (508) 698-2118
www.aemc.com
Customer Support – for placing an order, obtaining price & delivery:
customerservice@aemc.com
Sales Department – for general sales information:
sales@aemc.com
Repair and Calibration Service – for information on repair & calibration, obtaining a user manual:
repair@aemc.com
Technical and Product Application Support – for technical and application support:
techinfo@aemc.com
Webmaster – for information regarding www.aemc.com:
webmaster@aemc.com
South America, Central America, Mexico, Caribbean, Australia & New Zealand:
Chauvin Arnoux®, Inc.
d.b.a. AEMC®Instruments
15 Faraday Drive
Dover, NH 03820 USA
(978) 526-7667 • Fax (978) 526-7605
export@aemc.com
www.aemc.com
All other countries:
Chauvin Arnoux SCA
190, rue Championnet
75876 Paris Cedex 18, France
33 1 44 85 45 28 • Fax 33 1 46 27 73 89
info@chauvin-arnoux.com
www.chauvin-arnoux.com