136
PEH526 / 626
THERMAL RESISTANCE FOR DIFFERENT CASE SIZES, AS A FUNCTION OF CASE AIR SPEED V
At ambient temperature Ta = 40°C
Case Air speed v
v=0,5m/s v=1,0m/s v=2,0m/s v=3,0m/s v=4,0m/s v=5,0m/s
D x L
Rthca Rth Rthca Rth Rthca Rth Rthca Rth Rthca Rth Rthca Rth
mm °C/W °C/W °C/W °C/W °C/W °C/W
22 x 25 AB 24.3 25.1 19.1 20.0 14.8 15.7 13.2 14.1 11.4 12.3 10.3 11.1
22 x 30 AC 21.3 22.5 16.8 18.0 13.2 14.4 11.7 12.9 10.2 11.4 9.2 10.4
22 x 35 AD 19.1 20.5 15.1 16.6 11.9 13.4 10.7 12.1 9.4 10.8 8.5 9.9
22 x 40 AE 17.4 19.0 13.9 15.5 11.0 12.7 9.9 11.5 8.7 10.4 7.9 9.5
22 x 45 AF 16.1 17.6 12.9 14.4 10.4 11.8 9.3 10.8 8.3 9.7 7.5 9.0
22 x 50 AG 15.1 16.8 12.2 14.0 9.8 11.6 8.9 10.6 7.9 9.7 7.2 9.0
25 x 25 BB 21.9 22.8 17.2 18.1 13.4 14.3 11.8 12.6 10.2 11.1 9.2 10.0
25 x 30 BC 19.3 20.2 15.3 16.1 12.0 12.8 10.5 11.3 9.2 10.0 8.2 9.1
25 x 35 BD 17.2 18.2 13.7 14.7 10.8 11.8 9.6 10.6 8.4 9.4 7.6 8.6
25 x 40 BE 15.8 16.9 12.6 13.7 10.0 11.2 8.9 10.0 7.8 8.9 7.1 8.2
25 x 45 BF 14.7 16.2 11.8 13.3 9.4 10.9 8.4 9.9 7.4 8.9 6.8 8.3
25 x 50 BG 13.7 15.2 11.1 12.6 8.9 10.5 8.0 9.5 7.1 8.6 6.5 8.0
30 x 25 CB 18.9 19.5 14.9 15.5 11.7 12.3 10.0 10.6 8.7 9.3 7.8 8.4
30 x 30 CC 16.4 17.1 13.1 13.8 10.2 10.9 8.8 9.5 7.7 8.4 6.9 7.6
30 x 35 CD 14.8 15.6 11.8 12.6 9.3 10.1 8.0 8.9 7.0 7.9 6.3 7.2
30 x 40 CE 13.5 14.3 10.8 11.6 8.6 9.4 7.4 8.2 6.5 7.3 5.9 6.7
30 x 45 CF 12.5 13.3 10.0 10.9 8.0 8.9 7.0 7.8 6.2 7.0 5.6 6.5
30 x 50 CG 11.9 12.9 9.7 10.7 7.8 8.8 6.8 7.8 6.1 7.1 5.5 6.6
35 x 25 DB 16.5 17.0 13.1 13.6 10.5 11.0 8.6 9.1 7.5 8.0 6.7 7.2
35 x 30 DC 14.3 14.7 11.4 11.8 9.2 9.6 7.6 8.0 6.6 7.0 5.9 6.3
35 x 35 DD 12.9 13.4 10.3 10.8 8.3 8.8 6.9 7.4 6.0 6.5 5.4 5.9
35 x 40 DE 11.8 12.5 9.5 10.1 7.7 8.3 6.4 7.1 5.6 6.3 5.1 5.7
35 x 45 DF 10.9 11.6 8.8 9.5 7.1 7.9 6.0 6.7 5.3 6.0 4.8 5.5
35 x 50 DG 10.5 11.3 8.5 9.3 7.0 7.8 5.9 6.7 5.3 6.0 4.8 5.6
35 x 55 DH 9.6 10.3 7.8 8.5 6.4 7.1 5.4 6.1 4.8 5.5 4.4 5.1
35 x 60 DI 9.1 10.2 7.4 8.5 6.2 7.2 5.2 6.3 4.7 5.7 4.3 5.3
40 x 60 EI 8.2 9.0 6.7 7.6 5.5 6.3 4.6 5.5 4.1 5.0 3.8 4.7
40 x 70 EK 7.5 8.5 6.2 7.2 5.1 6.1 4.4 5.4 3.9 4.9 3.6 4.6
40 x 80 EM 7.0 8.3 5.9 7.2 4.9 6.2 4.2 5.5 3.8 5.1 3.5 4.8
40 x100 EQ 6.4 8.2 5.4 7.2 4.6 6.3 4.1 5.8 3.7 5.4 3.4 5.2
(Rthca = Thermal resistance between case and ambient)
© KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without KEMET'sprior express consent is prohibited.
Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute –
and we specifically disclaim – any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who
have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.