Specifications are subject to change without notice. - 1 - First issue: Dec. 1999 Rev.3: Jun. 2003
No. SS2-MGH200-0100 (Rev.3)
MagneW 3000 PLUS
Smart Electromagnetic Flowmeter
HENRI Flowmeter for Pulp Slurry
Model MGH14C (Converter) / MGH18 (Detector)
Size 40 to 400 mm (1½ to 16 inches)
Remote converter
OVERVIEW
The MagneW 3000 PLUS HENRI (High-Energy
Noise-Resistant Instrument) flowmeter is a high-
performance and highly reliable flowmeter for
Pulp & Paper applications based on Yamatake's
proven MagneW 3000 flow measurement tech-
nologies. The MagneW 3000 PLUS HENRI
offers a stable and accurate measurement for
severe Pulp and Paper applications with a unique
lining manufacturing technology and high-fre-
quency excitation technology.
FEATURES
Stable and accurate measurement by
high-frequency excitation technology
MagneW 3000 PLUS HENRI minimizes the output
fluctuation cause d b y various noises (Slurry noise,
AC noise and Electrochemical noise) and realizes
stable and accurate flow measurement for pulp
slurry applications.
High-performance lining
A unique high quality lining technology makes it
possible to offer mirror -finish PFA lining. The mir-
ror-finish PFA lining is best suited for scaling
applications.
A new material ETFE (harder than PFA) lining is
suitable for wearing applications in Pulp & Paper
process. ETFE lining extends life-time of lining
than (that of) PFA lining.
Replaceable face-to-face dimension
detector (Optional)
This detector can replace the detector of our exist-
ing models and those of other suppliers.
Please consult your Yamatake representative for
details.
Rugged detector structure
A stainless steel housing has been adopted for sizes
40 to 200 mm (1½ to 8 inches).
A watertight structure is used for the watertight
model (Model MGH18).
APPLICATIONS
Applications for pulp production, prepa-
ration and papermaking process
Pulpstock flow to head box
DIP (De-inked pulp) application
Pulp from screen
Green liquor
Diluted black liquor
Dye/pigment dosing application
White liquor
High consistency pulp
Pulp from pulper
No. SS2-MGH200-0100 (Rev.3) Yamatake Corporation
- 2 -
For converter (Model MGH14C)
FUNCTIONAL SPECIFICATIONS
Type of protection
JIS C 0920 waterproof model
NEMA ICS6-110 TYPE 4X
IEC PUBL 529 IP66
Input signal
Flow signal
Electromotive force from the detector
Contact input (optional)
Solid-sate contact or no-voltage contact
Output signal
Analog output
4 to 20mADC
Digital output
DE
Analog or digital output is selectable.
Contact output (optional)
Open collector
Contact capacity: 30 V DC max., 200mA max.
Pulse output (optional)
Open collector
Contact capacity: 30 V DC max., 200mA max.
Pulse frequency: 2000 Hz ma x.
Pulse width: 0.3 to 999.9 ms
Adjustable from 0.3 to 9 99.9 ms or fixed at 50%
of duty
Analog output range/load resistance
Without SFC communication
0.8mA to 22.4mA (-20% to +115%)
Load resistance: 0 to 600
With SFC communication
3.2mA to 22.4mA (-5% to +115%)
External power source for communication
DC16V to 45V
Load resistance = (External power source for Com-
munication -8.5 V) / 0.025
With HART communication
Load resistance: 250 minimum
Digital output range/load resistance
With SFC communication
3.2mA to 22.4mA (-5% to +115%)
External power source for SFC communication/
digital communication 16 to 45 V DC
Load resistance
= (External power source for Communication -
8.5V)/0.025
Unit of flow indication
Vo lume flow
m3, L, cm3, G, mG, kG, B
Mass flow
t, kg, g, lb
Time
d, h, min, s
Damping time
Adjustable between 0.5 and 199.9 seconds
Low flow cutoff
Adjustable between 0 to 10% of setting range.
Below selected value, output is driven to the zero
flow rate signal level.
Drop out
Adjustable between 0 to 10% of setting range.
Below selected value, pulse output is cut.
Lightning protection
12 kV, 1000A
Equipped with the lightning arrester in the power
source and external input and output terminals.
Power failure
An EEPROM retains data record of totalized value
when pulse output is used (retention period approxi-
mately 10 years).
Power supply
90 to 246 V AC
Power supply frequency
47 to 63 Hz
Power consumption
30 W max.
Ambient temperature limits
-25 to +50°C (-13 to +122°F)
Ambient humidity limits
5 to 100% RH
Yamatake Corporation No. SS2-MGH200-0100 (Rev.3)
- 3 -
Optional specifications
Display Indication by LCD with backlighting
Main display
7-segment, 6 digits
Sub display
16 digits, 2 lines
Display contents
Demonstrates three values simultaneously.
Flow volume in percentage
Actual flow volume
Totalized value (when pulse output selected)
Selection of main display and sub display
Main display is selectable from the three values.
Data setting device
Setting by infrared ray touch sensor
Infrared ray touch sensor: Four key switches
Contact input function
External 0% lock input
Forces outputs (analog, digital, pulse) to the zero
flow rate signal level.
Activates by applying a contact input.
External automatic zero adjustment input
Adjusts zero-point.
Activates by applying a contact input.
External range switching input
Switches two flow measurement ranges.
Two measurement ranges
Dual range for normal directions
Normal/reverse range
Activates by applying a contact input.
Built-in counter reset input (for pulse out-
put model)
Resets the totalized value of the built-in counter.
Activates by applying a contact input.
Contact output function
Alarm output
Outputs an alarm under the following conditions.
Self-diagnostic result
Empty detection
High/low limit alarm
Range switching output
Outputs the status of flow range.
Large/small in dual range
Normal/ Reverse
Counter preset status output (for pulse
output model)
Activates when the counter reaches the preset
value.
Self-check result output
Activates only when a self-diagnostic abnormal-
ity occurs.
Empty detection output
Activates only when an empty status is detected.
High/low limit alarm output
Activates when a high/low limit alarm occurs.
Two-stage flow rate alarm output (with
two contact outputs)
Activates when the first high/low limit alarm (H/
L) occurs and the second high/low limit alarm
(HH/LL) occurs.
Empty pipe detection
When the detector is empty, the analog output, digi-
tal output and pulse output are fixed at zero. Dis-
play is latched to zero.
Pulse output
Outputs the totalized value.
Must be selected in case of using totalizer.
Built-in counter function
Totalizer
According to the pulse scale setting, it totals one
count at a time, for normal and reverse flows.
Totalizer with presetting function
A preset value (target totaliz ed valu e) ca n be set
between 0000000000 and 9999999999. The
counting method is same as that of the standard
totalizer.
Normal/reverse flow difference totalizer
The difference in flow volumes in the normal and
reverse directions is calculated and displayed.
Traceability certificate
The following three documents are provided.
Traceability System Chart
Traceability Certificate
•Test Report
Tropicalization treatment
Protects the electromag netic flow meter in harsh
environments during tran spo rtation and/or storage.
The following treatments are applied.
Corrosion protection
Moisture prevention
Mildew proofing
Indication other than SI units
The following non-SI units are available.
Volume unit
B (barrel), kG (kilo-gallon), G (gallon), mG
(milli-gallon)
Mass unit
lb (pound)
No. SS2-MGH200-0100 (Rev.3) Yamatake Corporation
- 4 -
PHYSICAL SPECIFICATION
Housing material
Aluminum alloy
Finish
Standard
Baked acryl pa int
Corrosion-resistant
Baked acryl pa int
Corrosion-proof
Baked epoxy paint
Color
Light beige (Munsell 4Y7.2/1.3)
Display cover material
Tempered glass, 5 mm thick
Weight
3.7 kg (8.2 lb)
INSTALLATION
Model MGH18 detector must be coupled with model
MGH14C converter.
Electrical connection
G1/2 (PF1/2) internal thread, 1/2NPT internal thread,
CM20 internal thread, Pg13.5 internal thread
Mounting
Wall mounting, 2-inch pipe mounting
Grounding
Resistance less than 100
For detector (Model MGH18)
FUNCTIONAL SPECIFICATIONS
Type of protection
JIS C 0920 watertight model
NEMA ICS6-180 TYPE 4X
IEC PUBL 529 IP67
Size
Wafer style
40, 50, 80, 100, 150, 200 mm
(1½, 2, 3, 4, 6, 8 inches)
Flange style
40, 50, 80, 100, 150, 200, 250, 300, 350, 400 mm
(1½, 2, 3, 4, 6, 8, 10, 12, 14, 16 inches)
Flange rati ng
JIS 10K, JIS 16K, JIS 20K, JIS 30K,
JPI1 50, JPI 300, ANSI 150, ANSI 300,
DIN PN10, DIN PN16, DIN PN25, DIN PN40
(Size 40 to 200 mm (1½ to 8 inches))
JIS 10K, JIS 20K,
JPI 150, JPI 300
ANSI 150, ANSI 300,
DIN PN10, DIN PN16, DIN PN25
(Size 250 to 400 mm (10 to 16 inches))
Ambient temperature limits
-30 to +80°C (-22 to +176°F)
Ambient humidity limits
5 to 100% RH
Measurable electrical conductivity
Coupled with model MGH14C converter
20 µS/cm or greater
(In case of less than 20 µS/cm, consult your
Ya matake representative.)
Yamatake Corporation No. SS2-MGH200-0100 (Rev.3)
- 5 -
Temperature range pressure range process fluid
Measurement flow range
Velocity V(m/s) = K × Q
K = Flow conversion factor = 1/3600 × 4/(πD2)
Q = Flow rate (m3/h)
PFA lining ETFE lining
Size Minimum flow velocity range is 0
to 0.3 m/s (0 to 0.98 ft/s) Maximum flow velocity range is 0
to 10m/s (0 to 32.8 ft/s) Conversion
factor K
Minimum range Maximum range
mm inches m3/h GPM m3/h GPM
40 1½0 to 1.358 0 to 5.976 0 to 45.23 0 to 199.1 0.2210
50 2 0 to 2.121 0 to 9.337 0 to 70.68 0 to 311.2 0.1415
65 2½0 to 3.584 0 to 15.78 0 to 119.4 0 to 525.9 0.08371
80 3 0 to 5.429 0 to 23.90 0 to 180.9 0 to 796.7 0.05526
100 4 0 to 8.483 0 to 37.35 0 to 282.7 0 to 1244 0.03537
150 6 0 to 19.09 0 to 84.04 0 to 636.1 0 to 2801 0.01572
200 8 0 to 33.93 0 to 149.4 0 to 1130 0 to 4979 0.008842
250 10 0 to 53.02 0 to 233.5 0 to 1767 0 to 7781 0.005659
300 12 0 to 76.35 0 to 336.2 0 to 2544 0 to 11205 0.003930
350 14 0 to 104.0 0 to 457.6 0 to 3463 0 to 15251 0.002887
400 16 0 to 135.8 0 to 597.7 0 to 4523 0 to 19920 0.002210
2.94 MPa
(426 psi)
0.98 MPa
(142 psi)
-0.098 MPa
(-14.2 psi) -40
(-40) 80
(176) 120
(248) 160 C
(320 F)
1.96 MPa
(284 psi)
0.98 MPa
(142 psi)
-0.098 MPa
(-14.2 psi)-40
(-40) 100
(212) 120 C
(248 F)
Size: 40 to 200 mm (1
1
/
2
to 8 inches)
Size: 250 to 400 mm (10 to 16 inches)
: Standard
: Refer to factory basis
Consult your Yamatake representative
2.94 MPa
(426 psi)
0.98 MPa
(142 psi)
-0.098 MPa
(-14.2 psi)-40
(-40) 80
(176) 120 C
(248 F)
1.96 MPa
(284 psi)
0.98 MPa
(142 psi)
-0.098 MPa
(-14.2 psi)-40
(-40) 100
(212)120 C
(248 F)
Size: 80 to 200 mm (3 to 8 inches)
Size: 250 to 400 mm (10 to 16 inches)
: Standard
: Refer to factory basis
Consult your Yamatake representative
No. SS2-MGH200-0100 (Rev.3) Yamatake Corporation
- 6 -
Optional specifications
Test report
Calibration certificate, withstand voltage test, insu-
lation resistant, hydrostatic pressure test, physical
inspection are included.
Traceability certificate
The following three documents are included.
Traceability System Chart
Traceability Certificate
•Test Report
Material certificate
Material certificate for electrode/grounding ring
Gasket for plastic piping
When the detector is being mounted on plastic pipe,
attach this gasket between the lining and the
grounding ring, and between the g r ounding ring
and the plastic pipe flange.
Attaching the tag number to the terminal
box
Stamp the tag with the specified number and attach
to the terminal box. The maximum number of char-
acters of the tag number is 8.
Attaching the tag number to the neck sec-
tion
Stamp the tag with the specified number and attach
to the neck section of the detector with stainless
wire. The maximum number of characters of the
tag number is 16.
PERFORMANCE SPECIFICATIONS
Accuracy (model MGH14C with model
MGH18 detector)
Vs = velocity of setting range
PHYSICAL SPECIFICATIONS
Main body material
Measuring pipe material
SUS304 stainless steel
Flange
SUS304 stainless steel
(Size 40 to 50 mm (1½ to 2 inches))
Carbon steel + corrosion-preventive painting
(Size 80 to 400 mm (3 to 16 inches))
Housing
SUS304 stainless steel
(Size 40 to 200 mm (1½ to 8 inches))
Carbon steel
(Size 250 to 400 mm (10 to 16 inches))
Terminal box
Aluminum alloy
Finish
Standard
Terminal box
Baked acryl pa int
Case (size 250 to 400 mm (10 to 16 inches))
Polyurethane paint
Corrosion-resistant
Terminal box
Baked acryl pa int
Case (size 250 to 400 mm (10 to 16 inches))
Polyurethane paint
Corrosion-proof
Terminal box
Baked epoxy paint
Case (size 250 to 400 mm (10 to 16 inches))
Epoxy paint
Color
Light beige (Munsell 4Y7.2/1.3)
Process wetted materials
Lining
PFA (Size 40 to 400 mm (1½ to 16 inches))
ETFE (Size 80 to 400 mm (3 to 16 inches))
Electrode
SUS316L, Hastelloy C, titanium, zirconium, tanta-
lum, tungsten-carbide, platinum-iridium
Grounding ring
SUS316, Hastelloy C, titanium, zirconium, tanta-
lum, platinum
Gasket
PTFE (if grounding ring material is exotic.)
Vs (m/s) Velocity during
measurement >
Vs × 20%
Velocity during
measurements <
Vs × 20%
1.0 < Vs ± 10 ±0.5% of rate ±0.1% of Vs
0.3 < Vs ± 1.0 ±(0.1/Vs+0.4)% of
rate ±0.2(0.1/
Vs+0.4)% of Vs
Yamatake Corporation No. SS2-MGH200-0100 (Rev.3)
- 7 -
INSTALLATION
Electrical connection
G1/2 (PF1/2) internal thread
1/2NPT internal thread
CM20 internal thread
Pg13.5 internal thread
Pipe connection
Wafer (Size 40 to 200 mm (1½ to 8 inches))
Flange (Size 40 to 400 mm (1½ to 16 inches))
Grounding
Resistance less than 100
Length of straight pipe
Upstream side
A minimum five straight pipe diameters
A minimum 10 straight pipe diameters is required if
a diffuser/valve/pump is installed upstream side.
Downstream side
Two straight pipe diameters is recommended.
Cable (between remote detector and con-
verter)
Maximum length 300 m (984 ft)
(depends on fluid conductivity)
Outer diameter 10 to 12 mm (0.4 to 0.47 inch)
Signal cable
Dedicated cable: MGA12W
(O.D. 11.4 mm, 0.75 mm2) or equivalent (CVVS,
CEEV etc.)
Excitation cable
Dedicated cable: MGA12W
(O.D. 10.5 mm, 2 mm2) or equivalent (CVV and
others)
No. SS2-MGH200-0100 (Rev.3) Yamatake Corporation
- 8 -
MODEL SELECTION
HENRI converter
Model MGH14C converter must be coupled with model MGH18 HENRI type detector
Model MGH14C - I II III IV - V VI VII VIII - Y / Options (some options can be selected per each model)
Option “Y” must be specified for Yamatake version.
Basic model no. Selections Optional selections
Note) 1. In case of this code, option “B” must be selected.
Type / Basic model No. Lining material Pipe connection Size mm (inches) Page
Waterproof converter model MGH14C page 8
Watertight detector model MGH18D PFA / ETFE Wafer 40 to 20 0 1½ to 8 page 9
Watertight detector model MGH18F PFA / ETFE Flange 40 to 400 1½ to 16 page 10
MGH14C - -
I Power supply 90-264 V AC 50/60 Hz M
II output signal /
communication Volume flow 4-20mA DC output / without communication A
Volume flow 4-20mA DC output / with communication B
Volume flow DE output / with communication C
Volume flow HART protocol output / with communication H
III Electrical connec-
tion / watertight
gland
G1/2 internal thread / without watertight gland 1
G1/2 internal thread / with brass (Ni-plated) watertight gland 2
G1/2 internal thread / with plastic watertight gland 3
1/2NPT internal thread / without watertight gland 4
CM20 internal thread / without wate rtight gland 5
Pg13.5 internal thread / without watertight gland 6
G1/2 internal thread / with SUS304 watertight gland 7
IV Installation / wir-
ing direction Remote type Wall mounting with standard bracket G
2-inch pipe mounting with standard bracket H
Without mounting bracket X
V Finish Standard X
Corrosion-resistant finish 1
Corrosion-proof finish 2
VI Display None X
Main display: Instantaneous indication of flow volume in % A
Main display: Instantaneous indication of actual flow volume B
Main display: Indication of integrated flow volume (need pulse output board) Note 1 C
VII Contact inputs /
outputs None X
1 input and 1 output (ranging function, warning for contact input/output, etc.) 1
2 input (ranging function, external automatic zero adjustment input, etc.) 2
2 output (ranging function, warning for contact output, etc.) 3
VIII Style code None X
Options
Yamatake version (must be selected) Y
Empty pipe detection function A
Pulse output (open collector) B
Traceability certificate for converter C
Indication other than SI units H
Attachment of the TAG number to the terminal box for converter J
Yamatake Corporation No. SS2-MGH200-0100 (Rev.3)
- 9 -
HENRI detector
Wafer type (40 to 200 mm (1½ to 8 inches)) PFA / ETFE liner
Model MGH18D detector must be coupled with MGH14C converter
Model MGH18D - I II III IV V VI VII VII I IX - X XI - Y/Opti ons (s ome optio ns ca n be selecte d per e ach mode l)
Option “Y” must be specified for Yamatake version
Basic model no. Selections Optional selections
Note) 1. Must be selected for Tag no. re quirement
MGH18D - -
I Line size 40 mm (1½ inches) 040
50 mm (2 inches) 050
80 mm (3 inches) 080
100 mm (4 inches) 100
150 mm (6 inches) 150
200 mm (8 inches) 200
II Linear ETFE (Size 80 to 200 mm (3 to 8 inches)) E
PFA P
III Piping connection Wafer JIS 10K 11
Wafer JIS 20K 12
Wafer JIS 30K 13
Wafer ANSI 150 21
Wafer ANSI 300 22
Wafer DIN PN10 41
Wafer DIN PN16 42
Wafer DIN PN25 43
Wafer DIN PN40 44
Wafer JPI 150 61
Wafer JPI 300 62
IV Electrode SUS316L L
Hastelloy C C
Titanium K
Zirconium H
Tantalum T
Tungsten carbide W
Platinum iridium P
Others !
V Grounding ring SUS316 S
Hastelloy C C
Titanium K
Zirconium H
Tantalum T
Platinum iridium P
Others !
VI Elect rical connection /
watertight gland Remote
type G1/2 internal thread / without watertight gland 2
G1/2 internal thread / with brass (Ni-plated) watertight gland 3
G1/2 internal thread / with plastic watertight gland 4
1/2NPT internal thread / without watertight gland 5
CM20 internal thread / without watertight gland 6
Pg13.5 internal thread / without watertight gland 7
G1/2 internal thread / with SUS304 watertight gland 8
VII Face-to-face dimen-
sions Standard A
Others !
VIII Installation / wiring
direction Remote
type Upstream side (horizontal / vertical piping mounting) A
Downstream side (horizontal / vertical piping mounting) B
Horizontal piping mounting / left side viewed from upstream C
Horizontal piping mounting / right side viewed from upstream D
IX Calibration Standard A
Others !
X Finish Standard X
Corrosion-resistant finish 1
Corrosion-proof finish 2
XI Bolt / nut None X
Carbon steel 1
SUS304 2
Options
Yamatake version (must be selected) Y
Calibration certificate (sent to ordering location separately) A
T raceability certificate for detector B
Material certificate (only for electrodes and ground rings) C
With gasket for plastic piping J
Attachment of the TAG number to the terminal box for detector (Note 1) K
Attachment of the TAG number plate to neck section for detector (Note 1) L
No. SS2-MGH200-0100 (Rev.3) Yamatake Corporation
- 10 -
HENRI detector
Flange type (40 to 400 mm (1½ to 16 inches)) PFA / ETFE liner
Model MGH18F - I II III IV V VI VI I VIII IX X - XI - Y /Options (some o ptio ns c an be selected per ea ch mod el)
Option “Y” must be specified for Yamatake version
Basic model no. Selections Optional selections
MGH18F - -
I Line size 40 mm (1½ inches) 040
50 mm (2 inches) 050
80 mm (3 inches) 080
100 mm (4 inches) 100
150 mm (6 inches) 150
200 mm (8 inches) 200
250 mm (10 inches) 250
300 mm (12 inches) 300
350 mm (14 inches) 350
400 mm (16 inches) 400
II Linear ETFE (Size 80 to 400 mm (3 to 16 inches)) E
PFA P
III Piping connectionFlange JIS 10K J1
Flange JIS 20K J2
Flange JIS 30K J3
Flange ANSI 150 A1
Flange ANSI 300 A2
Flange DIN PN10 D1
Flange DIN PN16 D2
Flange DIN PN25 D3
Flange DIN PN40 D4
Flange JPI 150 P1
Flange JPI 300 P2
IV Flange material Standard 1
V Electrode SUS316L L
Hastelloy C C
Titanium K
Zirconium H
Tantalum T
T ungsten carbide W
Platinum iridium P
Others !
VI Grounding ring SUS316 S
Hastelloy C C
Titanium K
Tantalum T
Platinum iridium P
Others !
VI Electrical connection /
watertight gland Remote
type G1/2 internal thread / without watertight gland 2
G1/2 internal thread / with brass (Ni-plated) watertight gland 3
G1/2 internal thread / with plastic watertig ht gland 4
1/2NPT internal thread / without watertight gland 5
CM20 internal thread / without watertight gland 6
Pg13.5 internal thread / without watertight gland 7
G1/2 internal thread / with SUS304 watertight gland 8
VIII Face-to-face dimensions Standard A
Others !
IX Installation / wiring direc-
tion Remote
type Upstream side (horizontal / vertical piping mounting ) A
Downstream side (horizontal / vertical piping mounting) B
Horizontal piping mounting / left side viewed from upstream C
Horizontal piping moun ting / right side viewed from upstream D
X Calibration Standard A
Others !
XI Finish Standard X
Corrosion-resistant finish 1
Corrosion-proof finish 2
Options
Yamatake version (must be selected) Y
Note) 1. Must be selected for Tag no. requirement
Calibration certificate (sent to ordering location separately) A
Traceability certificate for detector B
Material certificate (only for electro de s an d gr ound rings) C
With gasket for plastic piping J
Attachment of the TAG number to the terminal box for detector (Note 1) K
Attachment of the TAG number plate to neck section for detector L
Yamatake Corporation No. SS2-MGH200-0100 (Rev.3)
- 11 -
DIMENSIONS
All dimensions are in millimeters, dimensions in brackets ( ) are in inches (inch).
Wafer type
Size: 40 to 200 mm (1½ to 8 inches)
Flange type
Size: 40 to 400 mm (1½ to 16 inches)
Note) The table indicated dimensions for ANSI 150 flange
Size mm 40 50 80 100 150 200
(inches)
(1½) (2) (3) (4) (6) (8)
Face to face
dimension Lmm 80 86 106 120 160 200
(inches)
(3.15) (3.39) (4.17) (4.72) (6.30) (7.87)
Height
H1 mm 84 93 108 120.5 160 185
(inches)
(3.31) (3.66) (4.25) (4.74) (6.30) (7.28)
H2 mm 43.5 52 67 79.5 110 135
(inches)
(1.71) (2.05) (2.64) (3.13) (4.33) (5.31)
H3 mm 174.5 192 222 247 317 367
(inches)
(6.87) (7.56) (8.74) (9.72) (12.48) (14.45)
H4 mm 109 118 133 145.5 185 210
(inches)
(4.29) (4.65) (5.24) (5.73) (7.28) (8.27)
Housing
width Wmm 125 135 164 189 240 290
(inches)
(4.92) (5.31) (6.46) (7.44) (9.45) (11.42)
Housing outer
diameter φDmm 87 104 134 159 220 270
(inches)
(3.43) (4.09) (5.28) (6.26) (8.66) (10.63)
Weight kg 2.8 3.4 5.2 6.7 13.6 22.0
(lb) (6.2) (7.5) (11.5) (14.8) (30.0) (48.5)
Size mm 40 50 80 100 150 200 250 300 350 400
(inches)
(1½) (2) (3) (4) (6) (8) (10) (12) (14) (16)
Face to face dimension L mm 200 200 200 250 300 350 450 500 550 600
(inches)
(7.87) (7.87) (7.87) (9.84) (11.81) (13.78) (17.72) (19.69) (21.65) (23.62)
Height
H1 mm 84 93 108 120.5 160 185 235 258 282 310
(inches)
(3.31) (3.66) (4.25) (4.74) (6.30) (7.28) (9.25) (10.16) (11.10) (12.20)
H2 mm 77 88 113 131 174 204 224 271 297 340
(inches)
(3.03) (3.46) (4.45) (5.16) (6.85) (8.03) (8.82) (10.67) (11.09) (13.39)
H3 mm 208 228 268 299 381 436 506 576 626 697
(inches)
(8.19) (8.98) (10.55) (11.77) (15.0) (17.17) (19.92) (22.68) (24.65) (27.44)
H4 mm 109 118 133 145.5 185 210 260 283 307 335
(inches)
(4.29) (4.65) (5.24) (5.73) (7.28) (8.27) (10.24) (11.14) (12.09) (13.19)
Weight kg 6.0 10.5 15.5 23.3 35.4 60.0 68.0 97.0 128.0 163.0
(lb) (13.2) (23.1) (34.2) (51.4) (78.0) (132) (150) (214) (282) (359)
(3.31)
(1.85)
(3.31)
(1.19 max.)
(3.31) (3.31)
(1.19 max.)
(1.85)
(3.31) (3.31)
(1.19 max.)
(1.85)
No. SS2-MGH200-0100 (Rev.3) Yamatake Corporation
- 12 -
Wall mount type
2-inch pipe mount type
(5.91) (0.55)
(4.33)
(5.04)
(0.13)
(9.76)
(8.50)
(5.12)(3.23)
(0.61)
(1.18) (1.34)
(0.98)
(4.06)
(5.04)
(1.74)
(4.06)
(0.57) (8.50)
(5.12)
(3.23)
(5.91)
(0.98)
(1.34)
(1.18)
(0.55)
Totate international Building
2-12-19 Shibuya
Shibuya-ku, Tokyo 150-8316
Japan
Tel :
Fax : 81-3-3486-2310
81-3-3486-2593
This has been printed on recycled paper. http://www.yamatake.com/