ELECTRICAL CHARACTERISTICS SLF0745
PART NO. INDUCTANCE TOLERANCE TEST DC RATED ITEMP
(µH) (±%) FREQUENCY RESISTANCE CURRENT (A) Max.
(KHz) (Ω) ±20% (A) Max.
SLF0745T-3R3M-N 3.3 20 1 0.02 2.50 2.30
SLF0745T-4R7M-N 4.7 20 1 0.03 2.00 2.10
SLF0745T-6R8M-N 6.8 20 1 0.039 1.70 1.74
SLF0745T-100M-N 10 20 1 0.036 1.30 1.78
SLF0745T-150M-N 15 20 1 0.052 1.10 1.53
SLF0745T-220M-N 22 20 1 0.061 0.90 1.34
SLF0745T-330M-N 33 20 1 0.096 0.82 1.09
SLF0745T-470M-N 47 20 1 0.125 0.75 0.92
SLF0745T-680M-N 68 20 1 0.175 0.60 0.77
SLF0745T-101M-N 100 20 1 0.25 0.50 0.65
SLF0745T-151M-N 150 20 1 0.34 0.40 0.55
SLF0745T-221M-N 220 20 1 0.52 0.33 0.45
SLF0745T-331M-N 330 20 1 0.74 0.25 0.37
SLF0745T-471M-N 470 20 1 1.05 0.22 0.31
SLF0745T-681M-N 680 20 1 1.48 0.20 0.27
SLF0745T-102M-N 1000 20 1 2.28 0.14 0.25
Note:
Rated Current: Value obtained when DC current ows and the initial value of inductance has fallen by 10%.
Itemp Current: Value obtained when current ows and the temperature has risen to 20 °C.
Test Equipment Inductance: HP4192A LF Impedance analyzer or equivalent (Test frequency: 1KHz/0.5V)
RDC: CH502BC
ELECTRICAL CHARACTERISTICS SLF1045
PART NO. INDUCTANCE TOLERANCE TEST DC RATED ITEMP
(µH) (±%) FREQUENCY RESISTANCE CURRENT (A) Max.
(KHz) (Ω) ±20% (A) Max.
SLF1045T-100M-N 10 20 1 0.0364 3.00 2.50
SLF1045T-150M-N 15 20 1 0.0472 2.40 2.20
SLF1045T-220M-N 22 20 1 0.0591 2.10 1.90
SLF1045T-330M-N 33 20 1 0.0815 1.60 1.70
SLF1045T-470M-N 47 20 1 0.10 1.40 1.50
SLF1045T-680M-N 68 20 1 0.14 1.20 1.30
SLF1045T-101M-N 100 20 1 0.20 1.00 1.10
SLF1045T-151M-N 150 20 1 0.35 0.79 0.81
SLF1045T-221M-N 220 20 1 0.47 0.65 0.70
SLF1045T-331M-N 330 20 1 0.68 0.54 0.58
SLF1045T-471M-N 470 20 1 1.03 0.47 0.47
SLF1045T-681M-N 680 20 1 1.60 0.38 0.38
SLF1045T-102M-N 1000 20 1 2.80 0.32 0.29
SLF1045T-152M-N 1500 20 1 3.40 0.22 0.26
Note:
Rated Current: Value obtained when DC current ows and the initial value of inductance has fallen by 10%.
Itemp Current: Value obtained when current ows and the temperature has risen to 30 °C.
Test Equipment Inductance: HP4192A LF Impedance analyzer or equivalent (Test frequency: 1KHz/0.5V)
RDC: CH502BC