Draka UK Ltd. Cardinal Cables, Crowther Road, Washington, Tyne & Wear, England. +44(0)191 417 3525
www.drakauk.com FAX +44 (0)191 416 8671
-100
-90
-80
-70
-60
-50
-40
-30
-20
-10
0
0 25 50 75 100 125 150
Frequency (MHz)
dB/100M
TYPICAL NEXT
NEXT LIMIT
ATT. LIMIT
TYPICAL ATT.
80
90
100
110
120
0 25 50 75 100 125
Frequency (MHz)
OHMS
Technical Specification Draka UK
Category 5e FTP Patch (AWG 26)
Cabling Application Applicable Standards
Structured Cable for Patch & Floor Outlet Installation
Compatible with all Known Connection systems
according to EN50173
Approved by BASEC 067/001/010
ISO/IEC 11801 – 2nd Edition
EN 50173; EN 50288-2-2 2000
ANSI/TIA/EIA-568-B.2.1-2002
Fire Propagation Test : UL 1581 VW1;
IEC 60332.1;EN50265-2-1
Cable construction
Conductor
Insulator Material
Number of Twisted Pairs
Screen Material (Laminated Foil Tape)
Sheath Material
Bare Cu Wire
PE
4
Al/PE
PVC or OHLS
Outside Diameter of Conductor
Outside Diameter of Insulation
Outside Diameter of Sheath
Weight PVC (OHLS)
Sheath Colour (OEM Specified)
Sheath Printing (up to 24 characters)
(7x0.16) 0.48 mm
0.94 mm
5.40 mm
34.8(36.5) kg/km
Various
Batch No. &
Metre marking
Cable Properties Electrical Characteristics @ 20 ºC
Min. Installation Bend Radius
Min. Installed Bending Radius
Max. Installation Tension
Max. Installed Tension
Installation Temp. Range Installed
Operating Temp. Range
8 x Dia
4 x Dia
100N
Zero
0 to 50ºC
-20 to 50ºC
Characteristic imped. (1-10&20-100Mhz)
Characteristic impedance (10-20Mhz)
DC Conductor Loop Resistance
Max. Resistance unbalance
Nominal Velocity of Propagation
Nominal Capacitance
Max. Capacitance unbalance
Insulation Resistance (500V)
100±15
100±12
30 /100m
2%
66%
50 pF/m
1600 pF/km
2000 M.km
Packaging
Reel Sizes
Length per Reel
Reel Dimensions
Weight (approx.)
P4 P5
500m 1000m
Ø400mm Ø500mm
19kg 38kg
Impedance Attenuation & NEXT