10 WATT DC-DC CONVERTER OES- SC / WC 0512 SINGLE/ DUAL CHANNEL Specifications Model OES**SC/WC05 OES05SC05 10WATTS/SINGLE/2 OUTPUT OES12SC05 OES15SC05 OES24SC05 OES22WC05 OES23WC05 5 5 5 5 5 Input Characteristic Input Voltage DC[V] Input Range DC[V] Inrush Current 5 4.5-9 Not specified [A] Input Range at no load [mA](typical) 36 34 28 41 83 90 at full load[mA](typical) 2500 2666 2530 2571 2700 2625 Line Back Noise [mVp-p](typical) 200 200 200 200 200 200 Efficiency [%] (typical) *1 80 81 83 84 80 80 Derating Curve ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Specifications Model OES**SC/WC05 10WATTS/SINGLE/2 OUTPUT Output Voltage [V] Output Current [A] Voltage Tolerance +/-[mV](maximum) *2 Ripple and Noise [mVp-p](maximum) *3 OES05SC05 OES12SC05 OES15SC05 5 2 100 12 0.9 240 15 0.7 300 OES24SC05 OES22WC05 24 0.45 480 +12 0.45 -12 0.45 240 OES23WC05 +15 0.35 -15 0.35 300 100 Regulation a.Static Line Regulation [mV](maximum) b.Dynamic Line Regulation +/-[mV](maximum) *4 c.Static Load Regulation +/-[mV](maximum) *5 +/-[mV](maximum) +/-[mV](maximum) 25 200 25 60 360 60 75 450 75 120 750 120 *6 *7 d.Temperature Coefficient *8 e.Drift[mV](maximum) *9 f.Dynamic Load Regulation +/- [mV](maximum) *10 g.Recovery Time *4,*10 Rise up time Hold up time Functions Overcurrent Protection >=110% of Rated Output Current [A] o 45 200 0.03%/ C(maximum) 90 135 75 +720 -720 450 750 1mS(typical) 500ms(typical) at rated input/output Not specified 75 360 2.2 0.99 0.77 0.495 Not available Remote Sence Not available Trimming of output voltage[mV] Not available Installed Input Fuse Environmental +900 -900 0.495 0.495 0.385 0.385 o -20 to 71 C Operating Temperature Storage Temperature Storage Humidity Withstanding Voltage Isolation Resistance Capacitance(input-output) [pF](typical) Vibration Shock Cooling Weight (typical) 90 Current Limiting with automatic recovery Overvoltage Protection (derating) Operating Humidity 60 75 360 450 60 75 +1200 -1200 +1500 -1500 o o o o 3.5%/ C(50 C to 71 C) (out of warranty >= 71 C ) 20-90%/RH(non-condensing) o -20 to +85 C 20 to 90%/RH(non-condensing) Primary-Secondary AC500V for 1minute Primary-Secondary 50M(minimum) by DC500V insulation tester 2200 5-10Hz:10mm double amplitude,10-55Hz:2G,20minutes' period for 60minutes each along X,Y,Z axes(non-operating) ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com 30G Convection open board type:14g Dimension Diagram ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: ETA-USA: OES23WC05 OES05SC05 OES22WC05 OES24SC05 OES15SC05 OES12SC05