TECHNICAL BULLETIN TB-4015 Series II Fume Extraction System Powerful, Portable Fume Extraction The MENDA Series II Fume Extraction System is a two-arm filtration system that combines powerful fan performance with efficient filtration. The compact design and easy set-up makes it truly portable. Depending on the application, three filter configurations are offered: The standard item (35470) comes with a 95% efficient Non-HEPA filtration for solder fumes. You also have the option of purchasing a HEPA filter (35472) or a Deep Bed Gas Filter (35473) for the removal of gases from solvents, conformal coating, etc. The air inlet ports allow the connection of 50 mm (2") or 63 mm (2.5") diameter exhaust arms. Inspection Item 35470 35471 35472 35473 35474 35475 35476 35477 35478 35479 35480 35481 35482 Description Series II Fume Extractor,w/ Non-HEPA Filter Pre-Filter (5PK), for use with (HEPA Filter, Gas Filter Only) Main Filter, HEPA 99.97% / Carbon Deep Bed Gas Filter 99.97% Main Filter, Non HEPA 95% 2.5' Arm w/6' Hose & Bracket Arm w/Bracket, Clamps Flex Exhaust Arm 2.5' Flex Exhaust Arm 5' Table Bracket, Clamps Connect Hose, 6' Connect Hose, 12' Remote SW, Series II 35470 Items included with model 35470: * 1 Unit with 35474 filter installed * 1 Remote Start/Stop Button (35482) * 1 Power Cord, 120V US Plug * 2 Flex Exhaust Arms 5' (35478) 3651 Walnut Avenue, Chino, CA 91710 Phone: (909) 627-2453 * Web Site: MendaPump.com TB-4015 July 2016 Page 1 of 5 (c) 2016 DESCO INDUSTRIES INC. Employee Owned Installation Extractor Installation Procedure Remove Fume Extractor from the shipping carton and inspect for any damages. Make sure you have access to the unit for filter maintenance. Connect the power cord into the outlet on the side of the system. Plug the power cord into a grounded wall socket. Connect the arms/hose to the inlet on the base of the fume extractor. To power up system, depress the power switch, located on the bottom right of the unit. The operator can expect a delay of a few seconds before hearing the motor running. This is due to the built-in motor "Soft-start" feature. If utilized, connect the supplied remote Start/Stop switch to the system and site the switch in a convenient position on the workbench. We recommend that this switch be used for your convenience. Position the extraction arms to optimize fume capture. Follow maintenance procedures on next page. Caution To provide protection against the risk of electrical shock, connect to properly grounded outlets only. Features * * * * * * * * * * * Efficient motor with "soft-start" feature Optional, remote Start/Stop switch Audible alarm to indicate blocked filters Low noise level <55 dba High suction force and airflow Compact and portable Standard Filter Efficiency at 95% (35474) Connects to 50mm (2") or 63mm(2.5") hoses or exhaust arms ESD safe housing Optional HEPA Filter Available (35472) Optional Gas Filter Available (35473) 3651 Walnut Avenue, Chino, CA 91710 Phone: (909) 627-2453 * Web Site: MendaPump.com TB-4015 Page 2 of 5 (c) 2016 DESCO INDUSTRIES INC. Employee Owned Maintenance General User maintenance is limited to cleaning the unit and replacing the filters with new. Only MENDA is authorized to carry out component testing and replacement. Unauthorized work or the use of unauthorized replacement filters may result in a potentially dangerous situation and/ or damage to the extractor unit, and will invalidate the manufacturer's warranty. Cleaning Unit To clean, use a light wipe with a gentle cleaner to prevent build up of particulate and flux residue. Be sure the unit is turned off while cleaning. The cooling inlets and outlets should be cleaned once a year to prevent build up of dust and overheating of which are on each side of the unit. Replacing Filters 1. Turn unit off and disconnect the power cord. 2. Unlatch both filter cover catches and remove the filter cover. (see below) Step 2: Unhook Latch Place Filter inside the Alignment Pins Step 1: Pull & Lift Latch Filter On/Off Switch Latch 3651 Walnut Avenue, Chino, CA 91710 Phone: (909) 627-2453 * Web Site: MendaPump.com TB-4015 Page 3 of 5 (c) 2016 DESCO INDUSTRIES INC. Employee Owned 3. Replace the main filter. Ensure the main filter is placed inside the alignment pins so that the interlock switch is depressed. 4. Replace the filter cover and ensure a proper fit to the bottom housing. Hook both latches into the filter cover and press down carefully to engage each latch to the base. 5. Reconnect power cord and turn system on. 6. If the unit does not operate, refer to the troubleshooting section. Problem Possible Cause No air flow No Power Poor Air Leak Performance Check Check On/Off switch Check power outlet Check power cord Check safety interlock switch Check hose/arm for leaks Check hose/arm for proper installation Check hose/arm for partial clogging Caution To prevent overheating, units should not be operated with a blocked filter condition, or with dust obstruction of inlets or outlets. Model 35470 Filter replacement indication As fumes are filtered inside the unit, any particulate will be captured and over time will start to clog the filter. This clogging will result in a reduction of the airflow, which may reduce the amount of fumes extracted from the work area. Once the filter starts to become blocked an audible alarm will sound from the main unit. This is to signify that filter replacement is required. 35472, 35473 - HEPA/GAS Filters Only As fumes are filtered inside the unit, any particulate will be captured and over time will start to clog the filter. The coarse particles are collected in the pre-filter while fine particulate will be collected in the HEPA filter. This clogging will result in a reduction of the airflow, which may reduce the amount of fumes extracted from the work area. Once the filters starts to become blocked an audible alarm will sound from the main unit. This is to signify that filter replacement. When using a HEPA or Gas Filter initially replace the pre-filter (35471). If this does not silence the alarm then replace the main filter too. Pre-filters should be replaced approximately every 4 - 6 weeks depending on the application. We recommend that a stock of replacement filters be kept for optimal extraction performance and minimum down-time. MENDA part number 35471. Warning! Do not attempt to clean filters. Attempted cleaning can damage filters and cause potential risk to health and equipment. Note: MENDA recommends replacement of Main Filters annually as a minimum. Use only original replacement filters. 3651 Walnut Avenue, Chino, CA 91710 Phone: (909) 627-2453 * Web Site: MendaPump.com TB-4015 Page 4 of 5 (c) 2016 DESCO INDUSTRIES INC. Employee Owned MENDA Series II Fume Extractor Specifications Capacity: Size: Weight: Rated Output: Electrical supply: 90 CFM height 20" x depth 10" x width 15.3" 20 lbs. / 9 kg 85 Watts 100 - 240 VAC, 1 phase 50-60 Hz Full Load Current: 0.3A (0.65A) Noise level: < 55dBA Filters: Filter Duct Size: Surface area Efficiency F7 2.0 m 95% @ 0.5 50mm Certification: TUV Approved Made in China Limited Warranty Menda expressly warrants that for a period of one (1) year from the date of purchase, Menda Fume Extraction Units will be free of defects in material (parts) and workmanship (labor). Within the warranty period, the product will be tested, repaired, or replaced at Menda's option, free of charge. Call our Customer Service Department at (909) 627-2453 for a Return Material Authorization (RMA) and proper shipping instructions and address. Include a copy of your original packing slip, invoice, or other proof of purchase date. Any unit under warranty should be shipped prepaid to the Menda factory. Warranty repairs will take approximately two weeks. If your unit is out of warranty, call Customer Service at (909) 627-2453 for a Return Material Authorization (RMA) and proper shipping instructions and address. Menda will quote repair charges necessary to bring your unit up to factory standards. Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED. The express warranty will not apply to defects or damage due to accidents, neglect, misuse, alterations, operator error, or failure to properly maintain, clean or repair products. Limit of Liability In no event will Menda or any seller be responsible or liable for any injury, loss or damage, direct or consequential, arising out of the use of or the inability to use the product. Before using, users shall determine the suitability of the product for their intended use, and users assume all risk and liability whatsoever in connection therewith. 3651 Walnut Avenue, Chino, CA 91710 Phone: (909) 627-2453 * Web Site: MendaPump.com TB-4015 Page 5 of 5 (c) 2016 DESCO INDUSTRIES INC. Employee Owned Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Desco: 35470 Menda: 35471 35472 35474 35475 35477 35478 35479