TECHNICAL BULLETIN TB-4015
Powerful, Portable Fume Extraction
The MENDA Series II Fume Extraction System is a two-arm ltration system that
combines powerful fan performance with e󰀩cient ltration. The compact design and easy set-up
makes it truly portable.
Depending on the application, three lter congurations are o󰀨ered: The standard item (35470)
comes with a 95% e󰀩cient Non-HEPA ltration for solder fumes. You also have the option of
purchasing a HEPA lter (35472) or a Deep Bed Gas Filter (35473) for the removal of gases
from solvents, conformal coating, etc.
The air inlet ports allow the connection of 50 mm (2") or 63 mm (2.5") diameter exhaust arms.
Inspection
Item Description
35470 Series II Fume Extractor,w/
Non-HEPA Filter
35471 Pre-Filter (5PK), for use with
(HEPA Filter, Gas Filter Only)
35472 Main Filter, HEPA 99.97% / Carbon
35473 Deep Bed Gas Filter 99.97%
35474 Main Filter, Non HEPA 95%
35475 2.5' Arm w/6' Hose & Bracket
35476 Arm w/Bracket, Clamps
35477 Flex Exhaust Arm 2.5'
35478 Flex Exhaust Arm 5'
35479 Table Bracket, Clamps
35480 Connect Hose, 6'
35481 Connect Hose, 12'
35482 Remote SW, Series II
Items included with model 35470:
1 Unit with 35474 lter installed
1 Remote Start/Stop Button (35482)
1 Power Cord, 120V US Plug
2 Flex Exhaust Arms 5' (35478)
35470
TB-4015 July 2016 Page 1 of 5
3651 Walnut Avenue, Chino, CA 91710
Phone: (909) 627-2453 • Web Site: MendaPump.com
© 2016 DESCO INDUSTRIES INC.
Employee Owned
TB-4015 Page 2 of 5
Installation
Extractor Installation Procedure
Remove Fume Extractor from the shipping carton and inspect for any damages. Make sure
you have access to the unit for lter maintenance.
Connect the power cord into the outlet on the side of the system. Plug the power cord into a
grounded wall socket.
Connect the arms/hose to the inlet on the base of the fume extractor.
To power up system, depress the power switch, located on the bottom right of the unit. The
operator can expect a delay of a few seconds before hearing the motor running. This is due to
the built-in motor “Soft-start” feature.
If utilized, connect the supplied remote Start/Stop switch to the system and site the switch
in a convenient position on the workbench. We recommend that this switch be used for your
convenience.
Position the extraction arms to optimize fume capture.
Follow maintenance procedures on next page.
Caution
To provide protection against the risk of electrical shock, connect to properly grounded outlets
only.
Features
E󰀩cient motor with “soft-start” feature
Optional, remote Start/Stop switch
Audible alarm to indicate blocked lters
Low noise level <55 dba
High suction force and airow
Compact and portable
Standard Filter E󰀩ciency at 95% (35474)
Connects to 50mm (2") or 63mm(2.5") hoses or exhaust arms
ESD safe housing
Optional HEPA Filter Available (35472)
Optional Gas Filter Available (35473)
3651 Walnut Avenue, Chino, CA 91710
Phone: (909) 627-2453 • Web Site: MendaPump.com
© 2016 DESCO INDUSTRIES INC.
Employee Owned
TB-4015 Page 3 of 5
Maintenance
General
User maintenance is limited to cleaning the unit and replacing the lters with new. Only
MENDA is authorized to carry out component testing and replacement. Unauthorized work or
the use of unauthorized replacement lters may result in a potentially dangerous situation and/
or damage to the extractor unit, and will invalidate the manufacturer’s warranty.
Cleaning Unit
To clean, use a light wipe with a gentle cleaner to prevent build up of particulate and ux
residue. Be sure the unit is turned o󰀨 while cleaning.
The cooling inlets and outlets should be cleaned once a year to prevent build up of dust and
overheating of which are on each side of the unit.
Replacing Filters
1. Turn unit o󰀨 and disconnect the power cord.
2. Unlatch both lter cover catches and remove the lter cover. (see below)
Place Filter inside
the Alignment Pins
Step 2:
Unhook
Latch
Step 1:
Pull & Lift
Latch
Filter
On/O󰀨
Switch
Latch
3651 Walnut Avenue, Chino, CA 91710
Phone: (909) 627-2453 • Web Site: MendaPump.com
© 2016 DESCO INDUSTRIES INC.
Employee Owned
TB-4015 Page 4 of 5
3. Replace the main lter. Ensure the main lter is placed inside the alignment pins so that the
interlock switch is depressed.
4. Replace the lter cover and ensure a proper t to the bottom housing. Hook both latches into
the lter cover and press down carefully to engage each latch to the base.
5. Reconnect power cord and turn system on.
6. If the unit does not operate, refer to the troubleshooting section.
Caution
To prevent overheating, units should not be operated with a blocked lter condition, or with dust
obstruction of inlets or outlets.
Model 35470
Filter replacement indication
As fumes are ltered inside the unit, any particulate will be captured and over time will start
to clog the lter. This clogging will result in a reduction of the airow, which may reduce the
amount of fumes extracted from the work area. Once the lter starts to become blocked an
audible alarm will sound from the main unit. This is to signify that lter replacement is required.
35472, 35473 - HEPA/GAS Filters Only
As fumes are ltered inside the unit, any particulate will be captured and over time will start to
clog the lter. The coarse particles are collected in the pre-lter while ne particulate will be
collected in the HEPA lter. This clogging will result in a reduction of the airow, which may
reduce the amount of fumes extracted from the work area. Once the lters starts to become
blocked an audible alarm will sound from the main unit. This is to signify that lter replacement.
When using a HEPA or Gas Filter initially replace the pre-lter (35471). If this does not silence
the alarm then replace the main lter too.
Pre-lters should be replaced approximately every 4 – 6 weeks depending on the application.
We recommend that a stock of replacement lters be kept for optimal extraction performance
and minimum down-time. MENDA part number 35471.
Warning! Do not attempt to clean lters. Attempted cleaning can damage lters and cause
potential risk to health and equipment.
Note: MENDA recommends replacement of Main Filters annually as a minimum. Use only
original replacement lters.
Problem Possible Cause Check
No air ow No Power Check On/O󰀨 switch
Check power outlet
Check power cord
Check safety interlock switch
Poor Air Leak Check hose/arm for leaks
Performance Check hose/arm for proper installation
Check hose/arm for partial clogging
3651 Walnut Avenue, Chino, CA 91710
Phone: (909) 627-2453 • Web Site: MendaPump.com
© 2016 DESCO INDUSTRIES INC.
Employee Owned
TB-4015 Page 5 of 5
MENDA Series II Fume Extractor Specications
Capacity: 90 CFM
Size: height 20" x depth 10" x width 15.3"
Weight: 20 lbs. / 9 kg
Rated Output: 85 Watts
Electrical supply: 100 – 240 VAC, 1 phase
50-60 Hz
Full Load Current: 0.3A (0.65A)
Noise level: < 55dBA
Filters: Filter Surface area 2.0 m²
E󰀩ciency F7 95% @ 0.5µ
Duct Size: 50mm
Certification: TUV Approved
Made in China
Limited Warranty
Menda expressly warrants that for a period of one (1) year from the date of purchase, Menda Fume Extraction Units will be free of defects
in material (parts) and workmanship (labor). Within the warranty period, the product will be tested, repaired, or replaced at Menda’s option,
free of charge. Call our Customer Service Department at
(909) 627-2453
for a Return Material Authorization (RMA) and proper shipping
instructions and address. Include a copy of your original packing slip, invoice, or other proof of purchase date. Any unit under warranty
should be shipped prepaid to the Menda factory. Warranty repairs will take approximately two weeks.
If your unit is out of warranty, call Customer Service at
(909) 627-2453
for a Return Material Authorization (RMA) and proper shipping
instructions and address. Menda will quote repair charges necessary to bring your unit up to factory standards.
Warranty Exclusions
THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED,
INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED. The
express warranty will not apply to defects or damage due to accidents, neglect, misuse, alterations, operator error, or failure to properly
maintain, clean or repair products.
Limit of Liability
In no event will Menda or any seller be responsible or liable for any injury, loss or damage, direct or consequential, arising out of the use
of or the inability to use the product. Before using, users shall determine the suitability of the product for their intended use, and users
assume all risk and liability whatsoever in connection therewith.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Desco:
35470
Menda:
35471 35472 35474 35475 35477 35478 35479