269Varispeed F7
CIMR-F7Z
Varispeed F7
The industrial workhorse
Flux vector control with or without PG
Silent operation. No current de-rating in silent mode.
Torque control
PID control
Powerful application oriented functionality
Stand still autotuning
High slip braking
Energy saving function.
Standard LCD operator
Standard RS485 communications - Modbus
Fieldbus options: DeviceNet, PROFIBUS,
CANOpen
Embedded OMRON PLC functionality with
PLC option card.
PC configuration tool: CX-Drive.
CE, UL, and cUL marking
Customized software *
The inverter software can be customized to meet
specific application. Examples:
Electronic line shaft (S-8169)
Crane software (S-7071)
* For detailed information please see CASE software section.
Ratings
200 V Class three-phase 0.4 to 110 kW
400 V Class three-phase 0.4 to 300 kW
System configuration
C22
R52
C24
PE
C16
U11
U8
R6
C26 C28
JP3
U6
U7
T1
U9
+
+
R15
R15
R25
R15
R20
R30
R7
R5
C5
R21
U14
C17
R14
R28
RR11
JP1
C1
U10
C3
R5
R1
R2
R36
R3
C21
R35
R70
R120
R75
R78
R114
C2
2
+
+
U1
+
C35 R99
U12
R95
R39
R40
R57
R56
D6
R6
U15
R54
R55
R8
TR2
11
R11
R110
R107
R113
TR1
C13
U13
C10
SI-N
CODE No.
U17
73600-C0210
JP5JP6RT4
R10
R10
R105
R102
C12
C11
R94
R97
R96
C20
R95
C39
R131
Y1
U10
C33
Communication option cards Reference option card
3G3IV-PCN329-E
Inverter to PC cable
3G3IV-PCN126/326
Digital operator
extension cable
JVOP-161-OY
Digital operator
(LED display)
JVOP-160 OY
Digital operator
(LCD display)
CX-Drive
Line filter Braking accessories
Feedback speed option card PLC option card
Varispeed
F7
Y203-EN2-02-Katalog.book Seite 269 Mittwoch, 24. Mai 2006 2:22 14
270 Frequency inverters
Type designation
200 V class
400 V class
Specifications
Model CIMR-F7Zo 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110
Max. applicable motor
output1
1. Our standard 4-pole motors are used for max. applicable motor output. Choose the inverter model whose rated current is allowable within the motor rated
current range.
kW 0.55 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110
Output
characteristics
Inverter capacity kVA 1.2 1.6 2.7 3.7 5.7 8.8 12 17 22 27 32 44 55 69 82 110 130 160
Rated current A3.2 4.1 7.0 9.6 15 23 31 45 58 71 85 115 145 180 215 283 346 4152
2. 322 A in case of heavy duty mode
Max. voltage 3-phase, 200/208/220/230/240 V (proportional to input voltage)
Max. output frequency Heavy duty (low carrier, constant torque applications): 150 Hz max
Normal duty 1 or 2 (high/reduced carrier, variable torque applications): 400 Hz max
Power
supply
Rated input voltage and
frequency 3-phase 200/208/220/230/240 V, 50/60 Hz3
3. When using the inverter of 200 V class 37 kW or more with a cooling fan of three-phase 230 V 50 Hz or 240 V 50/60 Hz power supply, a transformer for
the cooling fan is required.
Allowable voltage
fluctuation +10%, -15%
Allowable frequency
fluctuation ±5%
Harmonic
wave
prevention
DC reactor Option Provided
12-pulse input Not available Available4
4. A 3-wired transformer is required at 12-pulse input.
Model CIMR-F7Zo 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300
Max. applicable motor
output1
1. Our standard 4-pole motors are used for max. applicable motor output. Choose the inverter model whose rated current is allowable within the motor rated
current range.
kW 0.55 0.75 1.5 2.2 3.7 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 185 220 300
Output
characteristics
Inverter capacity kVA 1.4 1.6 2.8 4.0 5.8 6.6 9.5 13 18 24 30 34 46 57 69 85 110 140 160 200 230 280 390 510
Rated current A1.8 2.1 3.7 5.3 7.6 8.7 12.5 17 24 31 39 45 60 75 91 112 150 180 216 260 304 370 5062
2. 405 A in case of heavy duty mode
6753
3. 540 A in case of heavy duty mode
Max. voltage 3-phase, 380/400/415/440/460/480 V (proportional to input voltage)
Max. output frequency Heavy duty (low carrier, constant torque applications): 150 Hz max
Normal duty 1 or 2 (high/reduced carrier, variable torque applications): 400 Hz max
Power
supply
Rated input voltage and
frequency 3-phase 380/400/415/440/460/480 V, 50/60 Hz
Allowable voltage
fluctuation +10%, -15%
Allowable frequency
fluctuation ±5%
Harmonic
wave
prevention
DC reactor Option Provided
12-Pulse input Not available Available4
4. A 3-wired transformer is required at 12-pulse input.
CIMR – F7 Z 4 0P4 0
Inverter Protective enclosure
0: Open chassis type (IP00)
1: Enclosed type (IP20 / NEMA1)
Max. applicable motor output
0P4: 0.4 kW
022: 22 kW
300: 300 kW
F7 series
Specifications
Z: European standard
specifications
Voltage
2: 200 V class
4: 400 V class
"P" indicates a decimal
point
[ ]
~
~
Y203-EN2-02-Katalog.book Seite 270 Mittwoch, 24. Mai 2006 2:22 14
Varispeed F7 271
Common specifications
Enclosures
Common specifications
200 V
class
Model CIMR-F7Z20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110
Enclosed type - IP20) Available as standard Available for option N/A
Open chassis type -IP00 Available by removing the upper and lower cover of
enclosed type Available as standard
400 V
class
Model CIMR-F7Z40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300
Enclosed type - IP20 Available as standard Available for option N/A
Open chassis type - IP00 Available by removing the upper and lower cover of
enclosed type Available as standard
Model number CIMR-F7ZSpecification
Control characteristics
Control method Sine wave PWM Closed loop vector control, open loop vector control, V/f control, V/f with PG control
Torque characteristics Heavy duty (low carrier, constant torque applications): 2 kHz carrier frequency, 150% overload for 1 minute,
higher carrier frequency possible with current derating.
Normal duty 1 (high carrier, variable torque applications): maximum carrier frequency, depending on inverter capacity,
120% overload for 1 minute.
Normal duty 2 (variable torque applications): carrier frequency reduced, continuous overload capability increased
Speed control range 1:40 (V/f control)
1:100 (open loop vector control)
1:1000 (closed loop vector control)
Speed control accuracy ± 3% (V/f control)
± 0.03% (V/f control with PG)
± 0.2% (open loop vector control)
± 0.02% (closed loop vector control)
(25 °C ± 10 °C)
Speed control response 5 Hz (control without PG)
30 Hz (control with PG)
Torque limits Provided (4 quadrant steps can be changed by constant settings.) (Vector control)
Torque accuracy ± 5%
Frequency range 0.01 to 150 Hz (Heavy Duty), 0.01 to 400 Hz (Normal Duty 1 or 2)
Frequency accuracy
(temperature characteristics) Digital references: ± 0.01% (-10 °C to +40 °C)
Analog references: ± 0.1% (25°C ±10°C)
Frequency setting resolution Digital references: 0.01 Hz
Analog references: 0.025/50 Hz (11 bits plus sign)
Output frequency resolution 0.01 Hz
Overload capacity and
maximum current Heavy duty (low carrier, constant torque applications): 150% of rated output current for 1 minute
Normal duty 1 or 2 (high/reduced carrier, variable torque applications): 120% of rated output current for 1 minute
Frequency setting signal 0 to +10V, -10 to +10 V, 4 to 20 mA, pulse train
Accel/decel time 0.01 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration time settings)
Braking torque Approximately 20% (approximately 125% with braking resistor option, braking transistor built into inverters of 18.5 kW or less)
Main control functions Restarting after momentary power loss, speed search, overtorque/undertorque detection, torque limits, 17-speed control
(maximum), 4 acceleration and deceleration times, S-curve acceleration/deceleration, 3-wire control, auto-tuning
(rotational or stationary), dwell function, cooling fan ON/OFF control, slip compensation, torque compensation,
auto-restart after fault, jump frequencies, upper and lower limits for frequency references, DC braking for starting and stopping,
high-slip braking, advanced PID control, energy-saving control, MEMOBUS communications (RS-485/422, 19.2 kbps maximum),
2 motor parameter sets, fault reset and parameter copy function.
Protective functions
Motor protection Protection by electronic thermal overload relay.
Instantaneous overcurrent
protection Stops at approx. 200% of rated output current.
Fuse blown protection Stops for fuse blown.
Overload protection Heavy duty (low carrier, constant torque applications): 150% of rated output current for 1 minute
Normal duty 1 (high carrier, variable torque applications): 120% of rated output current for 1 minute
Normal duty 2 (high carrier, variable torque applications): 120% of rated output current for 1 minute,
increased continuous output current.
Overvoltage protection 200 class inverter: stops when main-circuit DC voltage is above 410 V.
400 class inverter: stops when main-circuit DC voltage is above 820 V.
Undervoltage protection 200 class inverter: stops when main-circuit DC voltage is below 190 V.
400 class inverter: stops when main-circuit DC voltage is below 380 V.
Momentary power loss ride
through By selecting the momentary power loss method, operation can be continued if power is restored within 2 s.
Cooling fin overheating Protection by thermistor.
Stall prevention Stall prevention during acceleration, deceleration and running independently.
Grounding protection Protection by electronic circuits.
Charge indicator Illuminates when the main circuit DC voltage is approx. 10 VDC or more.
Environment
Ambient operating temperature -10 °C to 40 °C (enclosed wall-mounted type)
-10 °C to 45 °C (open chassis type)
Ambient operating humidity 95% max. (with no condensation)
Storage temperature - 20 °C to + 60 °C (short-term temperature during transportation)
Application site Indoor (no corrosive gas, dust, etc.)
Altitude 1000 m max.
Vibration 10 to 20 Hz, 9.8 m/s2 max.; 20 to 50 Hz, 2 m/s2 max
Y203-EN2-02-Katalog.book Seite 271 Mittwoch, 24. Mai 2006 2:22 14
272 Frequency inverters
Dimensions
Open chassis type (IEC IP00)
Voltage Max. applicable motor
output kW Inverter
CIMR-F7ZFig Dimensions in mm Approx.
weight kg Cooling
method
W H D W1 H1 H2 D1 T1 d
200 V class (3-phase)
0.4 ------
Not available, please use the IP20 type removing the upper and lower cover
0.75 ------
1.5 ------
2.2 ------
3.7 ------
5.5 ------
7.5 ------
11 ------
15 ------
18.5 ------
22 2022 0
1
250 400 258 195 385 7.5 100 2.3 M6 21
Fan
cooled
30 2030 0 275 450 220 435 24
37 2037 0 375 600 298 250 575
12.5
100
3.2 M10
57
45 2045 0 328
130
63
55 2055 0 450 725 348 325 700 86
75 2075 0 87
90 2090 0 500 850 358 370 820 15 4.5 M12 108
110 2110 0 575 885 378 445 855 140 150
400 V class (3-phase)
0.4 ------
Not available, please use the IP20 type removing the upper and lower cover
0.75 ------
1.5 ------
2.2 ------
4.0 ------
5.5 ------
7.5 ------
11 ------
15 ------
18.5 ------
22 4022 0
1
275 450 258 220 435
7.5
100
2.3 M6
21
Fan
cooled
30 4030 0
37 4037 0
325 550 283 260 535 105 3645 4045 0
55 4055 0
75 4075 0 450 725 348 325 700 12.5
130
3.2 M10 88
90 4090 0 89
110 4110 0 500 850 358 370 820 15
4.5 M12
102
132 4132 0 120
160 4160 0 575 916 378 445 855 45.8 140 160
185 4185 0 710 1305 413 540 1270 15 125.5
260
220 4220 0 280
300 4300 0 916 1475 413 730 1440 405
Fig 1
W
W1 4-d
H2
(5) D1
D
H1
H
T1
(5)(5)
Y203-EN2-02-Katalog.book Seite 272 Mittwoch, 24. Mai 2006 2:22 14
Varispeed F7 273
Enclosed type (IEC IP20)
Voltage Max. applicable motor
output kW Inverter
CIMR-F7ZFig Dimensions in mm Approx.
weight kg Cooling
method
W H D W1 H0 H1 H2 H3 D1 T1 d
200 V class (3-phase)
0.4 20P4 1
1 140 280
157
126 280 266 7 ---
39
5M5
3Self
cooled
0.75 20P7 1
1.5 21P5 1
2.2 22P2 1
3.7 23P7 1 177 59 4
Fan
cooled
5.5 25P5 1
7.5 27P5 1
2
200 300 197 186 300 285 8 065.5
2.3 M6
6
11 2011 1 310 10 7
15 2015 1 240 350 207 216 350 335
7.5
078 11
18.5 2018 1 380 30
22 2022 1
3
254 535 258 195 400 385 135
100
24
30 2030 1 279 615 220 450 435 165 27
37 2037 1 380 809 298 250 600 575
12.5
209
3.2 M10
62
45 2045 1 328
130
68
55 2055 1 453 1027 348 325 725 700 302 94
75 2075 1 95
400 V class (3-phase)
0.4 40P4 1
1 140 280
157
126 280 266 7 ---
39
5M5
3Self
Cooled
0.75 40P7 1
1.5 41P5 1
2.2 42P2 1
177 59 4
Fan
cooled
3.7 43P7 1
4.0 44P0 1
5.5 45P5 1
7.5 47P5 1
2
200 300 197 186 300 285 8
---
65.5
2.3 M6
6
11 4011 1
15 4015 1 240 350 207 216 350 335
7.5
78 10
18.5 4018 1
22 4022 1
3
275 535 258 220 450 435 85 100 24
30 4030 1
37 4037 1
325 715 283 260 550 535 105 4045 4045 1 105
55 4055 1
75 4075 1 453 1027 348 325 725 700 12.5 302
130
3.2 M10 96
90 4090 1 97
110 4110 1 504 1243 358 370 850 820 15 393 4.5 M12
122
132 4132 1 130
160 4160 1 579 1324 378 445 918 855 45.8 408 140 170
3
W
H0
H
H1
H2
H3
4
W1 D1
D
W
W1
3
H1
H2
D
H0
D1
4H
4-d 4-d
W
W1
H3 H0
H1
H2
D1
D
(5)
H10
4-d
T1
(5)
(5)
H
Fig 1 Fig 2 Fig 3
T1 T1
F7Z 20P41 to F7Z25P51
F7Z40P41 to F7Z45P51
F7Z 27P51 to F7Z20181
F7Z47P51 to F7Z40181
F7Z 20221 to F7Z20751
F7Z40221 to F7Z41601
Y203-EN2-02-Katalog.book Seite 273 Mittwoch, 24. Mai 2006 2:22 14
274 Frequency inverters
Filters
Footprint / Flat filters
Bookform filters
Model Dimensions
A B C D E F G H I J K L
200 V
3G3RV-PFI2035-SE 330 141 46 281 313 115 5.5 M5 23 126 266 M5
3G3RV-PFI2060-SE 355 206 60 302 336 175 6.5 M6 30 186 285 M6
3G3RV-PFI2100-SE 408 236 80 355 390 205 6.5 M6 40 216 335 M6
400 V
3G3RV-PFI3010-SE 330 141 46 281 313 115 5.5 M5 23 126 266 M5
3G3RV-PFI3018-SE 330 141 46 281 313 115 5.5 M5 23 126 266 M5
3G3RV-PFI3021-SE 355 206 50 302 336 175 6.5 M4 25 186 285 M5
3G3RV-PFI3035-SE 355 206 50 302 336 175 6.5 M5 25 186 285 M6
3G3RV-PFI3060-SE 408 236 65 355 390 205 6.5 M6 32.5 216 335 M6
3G3RV-PFI3410-SE 1
1. Flat filters are not possible to be mounted as footprint filters.
386 115 260 306 240 235 12.0 M12 - - - -
3G3RV-PFI3600-SE 1386 135 260 306 240 235 12.0 M12 - - - -
3G3RV-PFI3800-SE 1564 160 300 516 420 275 9.0 M12 - - - -
CI
A
E
BF H
G
L
J
K
D
C
A
E
B
F
H
G
D
Model Dimensions
A B C D E F G H
200 V
3G3RV-PFI2130-SE 366 180 90 280 310 65 6.5 M10
3G3RV-PFI2160-SE 451 170 120 350 380 102 6.5 M10
3G3RV-PFI2200-SE 610 240 130 480 518 90 8.2 M10
400 V
3G3RV-PFI3070-SE 331 185 80 300 329 55 6.5 M6
3G3RV-PFI3100-SE 326 150 90 240 270 65 6.5 M10
3G3RV-PFI3130-SE 370 180 90 280 310 65 6.5 M10
3G3RV-PFI3170-SE 451 170 120 350 380 102 6.5 M10
3G3RV-PFI3200-SE 610 240 130 480 518 90 8.3 M10
Y203-EN2-02-Katalog.book Seite 274 Mittwoch, 24. Mai 2006 2:22 14
Varispeed F7 275
Braking unit
Braking resistor unit (inverter-mounted type)
Braking resistor unit (separately-installed type)
Model CDBR-2015 B, -2022 B, -4030B, -4045 B Model CDBR-2110 B
Weight 1.8 K Weight 8.5 Kg
Model CDBR-4220 B
Weight 12 Kg
4-M4 MTG holes 72
3838
128
140
30 or
more 30 or
more 138.5
114.5
3-lead wire inlet
(20 dia. rubber bush)
66.5
100 or more
150
100 or more
138
140
104
Lead wire inlet
(28 dia. rubber bush)
2-lead wire inlet
(35 dia. rubber bush)
111
156
200
100
59
30
or
more
50
140
180
12
36.5
317
100 or less 100 or less
73
350
370
4-M6
MTG holes
Main circuit
terminal
M6
30
or
more
Lead wire inlet
(28 dia. rubber bush)
2-lead wire inlet
(35 dia. rubber bush)
156.5
210
104
118.5
50
210
250 200
156
111
9
36.5
100 or more 100 or more
317
355
370
70
4-M6
MTG holes
Main circuit
terminal
M6
30
or
more
30
or
more
Note: Prepare mounting screws
(2-M4x8 tapped screws).
Screws 8mm or more and general
metric screws cannot be used.
Weight: 0.2 kg
Model ERF-150WJ_
Voltage Model
LKEB-_
Dimensions in mm Weight
kg
A B C D MTG screw
220 V
class
20P7 105 275 50 260 M5 x 3 3.0
21P5 130 350 75 335 M5 x 4 4.5
22P2 130 350 75 335 M5 x 4 4.5
23P7 130 350 75 335 M5 x 4 5.0
25P5 250 350 200 335 M6 x 4 7.5
25P5 250 350 200 335 M6 x 4 8.5
400 V
class
40P7 105 275 50 260 M5 x 3 3.0
41P5 130 350 75 335 M5 x 4 4.5
42P2 130 350 75 335 M5 x 4 4.5
43P7 130 350 75 335 M5 x 4 5.0
45P5 250 350 200 332 M6 x 4 7.5
47P5 250 350 200 332 M6 x 4 8.5
MTG screw
30 or more 30 or more
A
C
D
B
150
150 or more 150 or more
Voltage Model
LKEB-_
Dimensions in mm Weight
kg
A B C D MTG screw
220 V
class
2011 266 543 246 340 M8 x 4 10
2015 356 543 336 340 M8 x 4 15
2018 446 543 426 340 M8 x 4 19
2022 446 543 426 340 M8 x 4 19
400 V
class
4011 350 412 330 325 M6 x 4 16
4015 350 412 330 325 M6 x 4 18
4018 446 543 426 340 M8 x 4 19
4022 446 543 426 340 M8 x 4 19
4030 356 956 336 740 M8 x 4 25
4037 446 956 426 740 M8 x 4 33
4045 446 956 426 740 M8 x 4 33
MTG screw
200 or more 200 or more
50 or more 50 or more
A260
C
D
B
Y203-EN2-02-Katalog.book Seite 275 Mittwoch, 24. Mai 2006 2:22 14
276 Frequency inverters
Attachments
Heatsink external mounting attachment
The Varispeed G7 inverters under the 200/400 V class 15 kW or less need this attachment for mounting the heatsink externally. This attachment
expands the outer dimensions of the width and height of the inverter. (Attachment is not required for inverters of 18.5 kW or more.)
Panel cut for external mounting of cooling fin (heatsink)
W1
WD1D2
D3 or more
WallMounting panel
H1
H
CIMR-
G7C
Attachment
order code Dimensions in mm
W H W1 H1 D1 D2 D3
20P4
EZZ08676A 155 302 126 290 122.6
37.4 4020P7
21P5
22P2 57.4 60
23P7
25P5 EZZ08676B 210 330 180 316 136.1 63.4 70
27P5
2011 EZZ08676C 250 392 216 372 133.6 76.4 85
2015
40P4
EZZ08676A 155 302 126 290 122.6
37.4 40
40P7
41P5
57.4 6042P2
43P7
45P5 EZZ08676B 210 330 180 316 136.1 63.4 70
47P5
4011 EZZ08676C 250 392 216 372 133.6 76.4 85
4015
Fig 3
Fig 2
A
B
W
W1
(H3) (H3)
(H2)
(H2)
H1
H
2-5 dia. holes
4-d Tap
aa
aa
b
b
(W3)(W3)
(W2)(W2)
W1
W
aa
4-d Tap
(H2)(H3) (H2) (H3)
H1
H
B
A (W3)(W3)
(W2)(W2)
aa
W1
W
aa
4-d Tap
(59)(H3) (19) (H3)
H1
H
B
A (W3)(W3)
(W2)(W2)
aa
Fig 1
CIMR-
F7ZFig Dimensions in mm
W H W1
(W2) (W3)
H1 (H2) (H3) A B d
20P4
1
155 302 126 6 8.5 290 9.5 6 138 271 M5
20P7
21P5
22P2
23P7
25P5
27P5 210 330 180
8.5
6.5 316 9 7 197 298
M6
2011
2015 250 392 216 8.5 372 9.5 10 233 353
2018
2022
2
250 400 195 24.5 3 385 87.5
244 369
2030 275 450 220 435 269 419
2037 375 600 250
54.5 8
575 15
12.5
359 545
M10
2045
2055 450 725 325 700 13.5 434 673
2075
2090 500 850 370 57 8 820 19 15 484 782 M12
2110 575 885 445 55 10 855 555 817
40P4
1
155 302 126 6 8.5 290 9.5 6 138 271 M5
40P7
41P5
42P2
43P7
44P0
45P5
47P5 210 330 180
8.5
6.5 316 9 7 197 298
M6
4011
4015 250 392 216 8.5 372 9.5 10 233 353
4018
4022
2
275 450 220
24.5
3435
87.5
269 419
4030
4037
325 550 260 8 535 309 519
4045
4055
4075 450 725 325 54.5 8 700 13.5 12.5 434 673 M10
4090
4110 500 850 370 57 8 820 19 15 484 782 M12
4132
4160 3 575 925 445 55 10 895 1
1.The sizes are different between the top and the bottom. Refer Fig 3
15 555 817
Y203-EN2-02-Katalog.book Seite 276 Mittwoch, 24. Mai 2006 2:22 14
Varispeed F7 277
Installation
Standard connections
M2
M1 Contact output 1
[Default : Running]
M4
M3 Contact output 2
[Default : Zero speed]
M6
M5 Contact output 3
[Default :
Frequency agree 1]
MC
MB Fault contact output
250 VAC, 1A max.
30 VDC, 1A max.
MA
Multi-function digital output
250 VAC, 1A max.
30 VDC, 1A max.
Line
filter
L1
L2
L3
PE
T
M
3-phase power
380 to 480 V
50/60 Hz
Varispeed F7
CIMR-F7Z47P5
Forward run/stop S1
R/L1
S/L2
T/L3
U/T1
V/T2
W/T3
Reverse run/stop S2
S3
External fault
S4
Fault reset
S5
Multi-step speed setting 1
S6
S7
SN
Multi-step speed setting 2
Jog frequency selection
SC
SP 24V
Multi-function
digital inputs
[Factory setting]
+V
AC
A2 Multi-function analog input 2
[Default: Frequency bias
4 to 20mA (250 Ω )]
Analog input 1: Master
frequency reference
0 to +10V (20 kΩ )
A1
0V
RP
Analog input power supply
+15V, 20 mA
Pulse train input [Default:
Frequency reference input]
0 to 32 kHz
Analog input power supply
-15V, 20mA
-V
E(G) Shield
terminal
PP
4 to 20 mA
0 to 10 V
3
2k
MP
E(G)
AC
Pulse train output
0 to 32kHz (2.2 k )
[Default: Output frequency]
FM
+
-
AM
+
-
AC
AM
FM
Adjustment,
20 k
Multi-function analog output 1
(-10 to +10 V 2 mA / 4 to 20 mA)
[Default: Output frequency 0 to +10 V]
Multi-function analog output 2
(-10 to +10 V 2 mA / 4 to 20 mA)
[Default: Output current 0 to +10 V]
Shield
terminal
R+
R-
S+
S-
IG
Terminating
resistance
DC reactor to improve input
power factor (optional)
Short-circuit bar
Braking resistor unit (optional)
12B1 B2
UX
Shielded wires PTwisted-pair
Shielded wires
MEMOBUS
communication
RS-485/422
P
P
2
1
Fuses
Main contactor
Analog input setting
adjustment
Ω
2k Ω
Ω
Ω
Adjustment,
20 kΩ
Y203-EN2-02-Katalog.book Seite 277 Mittwoch, 24. Mai 2006 2:22 14
278 Frequency inverters
Main circuit
Voltage 200 V 400 V
Model CIMR-F7Z20P4 to 2018 2022, 2030 2037 to 2110 40P4 to 4018 4022 to 4055 4075 to 4300
Max. applicable motor output 0.4 to 18.5 kW 22 to 30 kW 37 to 110 kW 0.4 to 18.5 kW 22 to 55 kW 75 to 300 kW
R/L1 Main circuit input
power supply Main circuit input
power supply
R-R1, S-S1 and T-T1 have been wired
before shipment (See P59).
Main circuit input
power supply Main circuit input power supply
R-R1, S-S1 and T-T1 have been wired
before shipment
S/L2
T/L3
R1/L11
--- ---
S1/L21
T1/L31
U/T1
Inverter output Inverter output
V/T2
W/T3
B1 Braking resistor unit ------ Braking resistor unit ------
B2
•DC reactor
(1- 2)
•DC power supply1
(1 - )
1. 1 - DC power input does not conform to UL/c-UL listed standard.
•DC power supply
(1- 2)
1
•Braking unit
(3 - )
•DC reactor
(1- 2)
•DC power supply1
(1 - )
•DC power supply
(1- 2)
1
•Braking unit
(3 - )
1
2
3--- ---
/l2------ Cooling fan power
supply2
2. Cooling fan power supply r/l1- /l2: 200 to 220 VAC 50 Hz, 200 to 230 VAC 60 Hz
(A transformer is required for 230 V 50 Hz or 240 V 50/60 Hz power supply.)
---
r/l1
--- Cooling fan power
supply3
3. Cooling fan power supply r/l1 - 200 / l2 200: 200 to 220 VAC 50 Hz, 200 to 230 VAC 60 Hz, r/l1 - 400 / l2 400: 380 to 480 VAC 50/60 Hz
200 / l2 200 ------
400 / l2 400
Ground terminal (100 Ω or less) Ground terminal (10 Ω or less)
Main circuit configuration
200 V class400 V class
CIMR
-
F7Z20P4
t
o
2018
CIMR-F7Z2022, 2030 CIMR-F7Z2037 to 2110
CIMR
-
F7Z40P4
t
o
4018
CIMR-F7Z4022 to 4055 CIMR-F7Z4075 to 4300
Y203-EN2-02-Katalog.book Seite 278 Mittwoch, 24. Mai 2006 2:22 14
Varispeed F7 279
Control circuite
Type No. Signal name Function Signal level
Digital input signals
S1 Forward run/stop command Forward run when ON; stopped when OFF. 24 VDC, 8 mA
photocoupler
S2 Reverse run/stop command Reverse run when ON; stopped when OFF.
S3 External fault input 1 Fault when ON. Functions are selected by
setting H1-01 to H1-05.
S4 Fault reset 1 Reset when ON
S5 Multi-step speed reference 1 1
(master/auxiliary switch)
1. The default settings are given for terminals S3 to S7. For a 3-wire sequence, the default settings are a 3-wire sequence for S5, multi-step speed setting
1 for S6 and multi-step speed setting 2 for S7.
Auxiliary frequency reference
when ON.
S6 Multi-step speed reference 2 1 Multi-step setting 2 when ON.
S7 Jog frequency reference 1Jog frequency when ON.
SC Digital input common
SN Digital input neutral
SP Digital input power supply +24 VDC power supply for digital inputs 24 VDC, 250 mA max. 2
2. Do not use this power supply for supplying any external equipment.
Analog input signals
+V 15 V power output 15 V power supply for analog references 15 V
(max. current: 20 mA)
-V-15 V power output -15 V power supply for analog references -15 V
(max. current: 20 mA)
A1 Frequency reference -10 to +10 V/100% -10 to +10 V(20 kΩ)
A2 Multi-function analog input 4 to 20 mA/100%
-10 V to +10 V/100% Function is selected by
setting H3-09. 4 to 20 mA(250 Ω)
-10 V to +10 V(20 kΩ)
AC Analog reference common
E(G) Shield wire, optional ground line
connection point ––
Sequence output signals
M1 Running signal
(1NO contact) Operating when ON. Multi-function contact
outputs Relay contacts
Contact capacity:
1 A max. at 250 VAC
1 A max. at 30 VDC 3
M2
M3 Zero speed Zero level (b2-01) or below when ON
M4
M5 Speed agreement detection Within ±2 Hz of set frequency when
ON.
M6
MA Fault output signal Fault when CLOSED across MA and MC
Fault when OPEN across MB and MC Relay contacts
Contact capacity:
1 A max. at 250 VAC
1 A max. at 30 VDC 3
3. When driving a reactive load, such as a relay coil with DC power supply, always insert a flywheel diode.
MB
MC
Analog output
signals
FM Multi-function analog output
(frequency output) 0 to 10 V, 10V=100% output
frequency Multi-function
analog output 1 -10 to +10 V max. ±5%
2 mA max.
4 to 20 mA current output
AC Analog common
AM Multi-function analog output
(current monitor) 0 to 10 V, 10V=200% inverter's rated
current Multi-function
analog output 2
Pulse I/O
RP Pulse input 4
4. Pulse input specifications are given in the following table.
H6-01 (frequency reference input) 0 to 32 kHz (3 kΩ)
High level voltage 3.5 to 13.2 V
MP Pulse monitor H6-06 (output frequency) 0 to 32 kHz
+15 V output (2.2 kΩ)
RS-485/422
R+ MEMOBUS communications input For 2-wire RS-485, short R+ and S+ as well as R- and S-. Differential input,
photocoupler isolation
R-
S+ MEMOBUS communications output Differential input,
photocoupler isolation
S-
IG Signal common
Low level voltage 0.0 to 0.8 V
High level voltage 3.5 to 13.2 V
H duty 30% to 70%
f
Y203-EN2-02-Katalog.book Seite 279 Mittwoch, 24. Mai 2006 2:22 14
280 Frequency inverters
Inverter heat loss
200 V class
400 V class
Connections for braking units Connections for braking resistors
Model CIMR-F7Z20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110
Inverter capacity kVA 1.2 1.6 2.7 3.7 5.7 8.8 12 17 22 27 32 44 55 69 82 110 130 160
Rated current A 3.2 4.1 7.0 9.6 15 23 31 45 58 71 85 115 145 180 215 283 346 415
Heat loss W
Fin W 20 27 50 70 112 164 219 374 429 501 586 865 1015 1266 1588 2019 2437 2733
Inside unit W 39 42 50 59 74 84 113 170 183 211 274 352 411 505 619 838 997 1242
Total heat loss W 59 69 100 129 186 248 332 544 612 712 860 1217 1426 1771 2207 2857 3434 3975
Fin coding Self cooled Fan cooled
Model CIMR-F7Z
40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5
4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300
Inverter capacity kVA 1.4 1.6 2.8 4.0 5.8 6.0 9.5 13 18 24 30 34 46 57 69 85 110 140 160 200 230 280 390 510
Rated current A1.8 2.1 3.7 5.3 7.6 8.0 12.5 17 24 31 39 45 60 75 91 112 150 180 216 260 304 370 506 675
Heat loss W
Fin W14 17 36 59 80 91 127 193 252 326 426 466 678 784 901 1203 1399 1614 2097 2388 2791 3237 3740 5838
Inside unit W39 41 48 56 68 70 82 114 158 172 208 259 317 360 415 495 575 671 853 1002 1147 1372 1537 2320
Total heat loss W53 58 84 115 148 161 209 307 410 498 634 725 995 1144 1316 1698 1974 2285 2950 3390 3938 4609 5277 8158
Fin coding Self cooled Fan cooled
Internal heatsink
55 ˚C
45 ˚C
Upper cover
Upper part air
temperature
-10 to 55 ˚C
Open chassis
type inverter
Inverter inlet
temperature
-10 to 45 ˚C
Peripheral
temperature 40 ˚C
Lower cover
Heatsink
Remove the upper and lower covers for
the models of 15 kW or less in 200 V
and 400 V classes.
When using open chassis type inverters of 200 V/400 V
22 kW or more, secure spaces for eyebolts and wiring
of the main circuit.
Upper cover
50 mm or more
50 mm or more 120 mm or more
120 mm or more
30 mm or more 30 mm
or more
Heatsink
Lower cover Side spaces Top and bottom spaces
Cover MTG screw
Air
Air
Varispeed F7
Braking
resistor
· Set constant L8-01 to 1
(mounting type braking
resistor protection
enabled).
· Set sequence to shutt off
the power side at inverter
fault contact output.
3-phase
Power
Supply
MCCB
Motor
Varispeed F7
Level Detector
Braking
resistor
unit
Braking
resistor
unit *
3
Braking unit 2*
2
Braking unit 1
Braking resistor overload
relay trip contact
(thermal relay trip contact)
Cooling fin overheat contact
(thermoswitch contact) Cooling fin overheat contact
(thermoswitch contact)
Braking resistor overload
relay trip contact
(thermal relay trip contact)
Y203-EN2-02-Katalog.book Seite 280 Mittwoch, 24. Mai 2006 2:22 14
Varispeed F7 281
AC reactor
DC reactor
200 V class 400 V class
Max. applicable
motor output kW Current value
AInductance
mH Max. applicable
motor output kW Current value
AInductance
mH
0.4 2.5 4.2 0.4 1.3 18.0
0.75 5 2.1 0.75 2.5 8.4
1.5 10 1.1 1.5 5 4.2
2.2 15 0.71 2.2 7.5 3.6
3.7 20 0.53 3.7 10 2.2
5.5 30 0.35 5.5 15 1.42
7.5 40 0.265 7.5 20 1.06
11 60 0.18 11 30 0.7
15 80 0.13 15 40 0.53
18.5 90 0.12 18.5 50 0.42
22 120 0.09 22 60 0.36
30 160 0.07 30 80 0.26
37 200 0.05 37 90 0.24
45 240 0.044 45 120 0.18
55 280 0.038 55 150 0.15
75 360 0.026 75 200 0.11
90 500 0.02 90/110 250 0.09
110 500 0.02 132/160 330 0.06
185 490 0.04
220
300 660 0.03
Connection example
MCCB
AC reactor
Application example
Inverter capacity (kVA)
Motor
Power supply
capacity (kVA)
AC Reactor required for
power supply harmonics
AC reactor not
required
Varispeed F7
200 V class 400 V class
Max. applicable
motor output kW Current value
AInductance
mH Max. applicable
motor output kW Current value
AInductance
mH
0.4 5.4 8 0.4 3.2 28
0.75 0.75
1.5
18 3
1.5 5.7 11
2.2 2.2
3.7 3.7 12 6.3
5.5 36 1 5.5 23 3.6
7.5 7.5
11 72 0.5 11 33 1.9
15 15
18.5 90 0.4 18.5 47 1.3
22 to 110 Built-in 22 to 300 Built-in
Varispeed F7
Take off the
common bar
between G1
and G2, and
wire as shown
in the diagram.
DC reactor
Motor
MCCB
Power
supply
capacity
(kVA)
Inverter capacity (kVA)
Without reactor
With reactor for
power supply
coordination
Y203-EN2-02-Katalog.book Seite 281 Mittwoch, 24. Mai 2006 2:22 14
282 Frequency inverters
Fuse installation
To protect the inverter, it is recommended to use semiconductor fuses as shown in the table below
Inverter type FUSE
Voltage (V) Current (A) I2t (A2s)
20P4 240 10 12~25
20P7 240 10 12~25
21P5 240 15 23~55
22P2 240 20 34~98
23P7 240 30 82~220
25P5 240 40 220~610
27P5 240 60 290~1300
2011 240 80 450~5000
2015 240 100 1200~7200
2018 240 130 1800~7200
2022 240 150 870~16200
2030 240 180 1500~23000
2037 240 240 2100~19000
2045 240 300 2700~55000
2055 240 350 4000~55000
2075 240 450 7100~64000
2090 240 550 11000~64000
2110 240 600 13000~83000
Inverter type FUSE
Voltage (V) Current (A) I2t (A2s)
40P4 480 5 6~55
40P7 480 5 6~55
41P5 480 10 10~55
42P2 480 10 18~55
43P7 480 15 34~72
44P0 480 20 50~570
45P5 480 25 100~570
47P5 480 30 100~640
4011 480 50 150~1300
4015 480 60 400~1800
4018 480 70 700~4100
4022 480 80 240~5800
4030 480 100 500~5800
4037 480 125 750~5800
4045 480 150 920~13000
4055 480 150 1500~13000
4075 480 250 3000~55000
4090 480 300 3800~55000
4110 480 350 5400~23000
4132 480 400 7900~64000
4160 480 450 14000~250000
4185 480 600 20000~250000
4220 480 700 34000~400000
4300 480 900 52000~920000
Y203-EN2-02-Katalog.book Seite 282 Mittwoch, 24. Mai 2006 2:22 14
Varispeed F7 283
Ordering information
Varispeed F7
200 V 400 V
C22
R52
C24
PE
C16
U11
U8
R6
C26 C28
JP3
U6
U7
T1
U9
+
+
R15
R15
R25
R15
R20
R30
R7
R5
C5
R21
U14
C17
R14
R28
RR11
JP1
C1
U10
C3
R5
R1
R2
R36
R3
C21
R35
R70
R120
R75
R78
R114
C2
2
+
+
U1
+
C35 R99
U12
R95
R39
R40
R57
R56
D6
R6
U15
R54
R55
R8
TR2
11
R11
R110
R107
R113
TR1
C13
U13
C10
SI-N
CODE No.
U17
73600-C0210
JP5 JP6 RT4
R10
R10
R105
R102
C12
C11
R94
R97
R96
C20
R95
C39
R131
Y1
U10
C33
F
E
G
D C B
A
FFFF
Communication option cards Reference option card
3G3IV-PCN329-E
Inverter to PC cable
3G3IV-PCN126/326
Digital operator
extension cable
JVOP-161-OY
Digital operator
(LED display)
JVOP-160 OY
Digital operator
(LCD display)
CX-Drive
Line filter Braking accessories
Feedback speed option card PLC option card
Varispeed
F7
Specifications Model
IP20
0.55 Kw 3.2 A CIMR-F7Z20P41
0.75 Kw 4.1 A CIMR-F7Z20P71
1.5 Kw 7.0 A CIMR-F7Z21P51
2.2 Kw 9.6 A CIMR-F7Z22P21
3.7 Kw 15 A CIMR-F7Z23P71
5.5 Kw 23 A CIMR-F7Z25P51
7.5 Kw 31 A CIMR-F7Z27P51
11 Kw 45 A CIMR-F7Z20111
15 Kw 58 A CIMR-F7Z20151
18.5 Kw 71 A CIMR-F7Z20181
IP00
22 Kw 85 A CIMR-F7Z20220
30 Kw 115 A CIMR-F7Z20300
37 Kw 145 A CIMR-F7Z20370
45 Kw 180 A CIMR-F7Z20450
55 Kw 215 A CIMR-F7Z20550
75 Kw 283 A CIMR-F7Z20750
90 Kw 346 A CIMR-F7Z20900
110 Kw 415 A CIMR-F7Z21100
Specifications Model
IP20
0.55 Kw 1.8 A CIMR-F7Z40P41
0.75 Kw 2.1 A CIMR-F7Z40P71
1.5 Kw 3.7 A CIMR-F7Z41P51
2.2 Kw 5.3 A CIMR-F7Z42P21
3.7 Kw 7.6 A CIMR-F7Z43P71
4.0 Kw 8.7 A CIMR-F7Z44P01
5.5 Kw 12.5 A CIMR-F7Z45P51
7.5 Kw 17 A CIMR-F7Z47P51
11 Kw 24 A CIMR-F7Z40111
15 Kw 31 A CIMR-F7Z40151
18.5 Kw 39 A CIMR-F7Z40181
IP00
22 Kw 45 A CIMR-F7Z40220
30 Kw 60 A CIMR-F7Z40300
37 Kw 75 A CIMR-F7Z40370
45 Kw 91 A CIMR-F7Z40450
55 Kw 112 A CIMR-F7Z40550
75 Kw 150 A CIMR-F7Z40750
90 Kw 180 A CIMR-F7Z40900
110 Kw 216 A CIMR-F7Z41100
132 Kw 260 A CIMR-F7Z41320
160 Kw 304 A CIMR-F7Z41600
185 Kw 370 A CIMR-F7Z41850
220 Kw 506 A CIMR-F7Z42200
300 Kw 675 A CIMR-F7Z43000
Y203-EN2-02-Katalog.book Seite 283 Mittwoch, 24. Mai 2006 2:22 14
284 Frequency inverters
A Line filters
200 V 400 V
B Feedback speed control cards
Inverter model Line filters
Varispeed F7 Type EN55011
class Current
(A) Weight
(kg)
CIMR-F7Z20P4 3G3RV-PFI3010-SE B, 25 m
A, 100 m 10 1.2
CIMR-F7Z20P7
CIMR-F7Z21P5
CIMR-F7Z22P2 3G3RV-PFI3018-SE B, 25 m
A, 100 m 18 1.3
CIMR-F7Z23P7 3G3RV-PFI2035-SE B, 25 m
A, 100 m 35 1.4
CIMR-F7Z25P5
CIMR-F7Z27P5 3G3RV-PFI2060-SE B, 25 m
A, 100 m 60 3
CIMR-F7Z2011
CIMR-F7Z2015 3G3RV-PFI2100-SE B, 25 m
A, 100 m 100 4.9
CIMR-F7Z2018
CIMR-F7Z2022 3G3RV-PFI2130-SE A, 100 m 130 4.3
CIMR-F7Z2030
CIMR-F7Z2037 3G3RV-PFI2160-SE A, 100 m 160 6.0
CIMR-F7Z2045 3G3RV-PFI2200-SE A, 100 m 200 11.0
CIMR-F7Z2055
CIMR-F7Z2075 3G3RV-PFI3400-SE A, 100 m 400 8.6
CIMR-F7Z2090
CIMR-F7Z2110 3G3RV-PFI3600-SE A, 100 m 600 11.0
Inverter model Line filter
Varispeed F7 Model EN 55011
class* Current
(A) Weight
(kg)
CIMR-F7Z40P4
3G3RV-PFI3010-SE B, 25 m
A, 100 m 10 1.2
CIMR-F7Z40P7
CIMR-F7Z41P5
CIMR-F7Z42P2
CIMR-F7Z43P7
3G3RV-PFI3018-SE B, 25 m
A, 100 m 18 1.3CIMR-F7Z44P0
CIMR-F7Z45P5
CIMR-F7Z47P5 3G3RV-PFI3021-SE B, 25 m
A, 100 m 21 1.8
CIMR-F7Z4011 3G3RV-PFI3035-SE B, 25 m
A, 100 m 35 2.2
CIMR-F7Z4015 3G3RV-PFI3060-SE B, 25 m
A, 100 m 60 4.0
CIMR-F7Z4018
CIMR-F7Z4022 3G3RV-PFI3070-SE B, 25 m
A, 100 m 70 3.4
CIMR-F7Z4030
CIMR-F7Z4037 3G3RV-PFI3100-SE A, 100 m 100 4.5
CIMR-F7Z4045
CIMR-F7Z4055 3G3RV-PFI3130-SE A, 100 m 130 4.7
CIMR-F7Z4075 3G3RV-PFI3170-SE A, 100 m 170 6.0
CIMR-F7Z4090 3G3RV-PFI3200-SE A, 100 m 250 11
CIMR-F7Z4110
CIMR-F7Z4132 3G3RV-PFI3400-SE A, 100 m 400 8.5
CIMR-F7Z4160
CIMR-F7Z4185 3G3RV-PFI3600-SE A, 100 m 600 11.0
CIMR-F7Z4220
CIMR-F7Z4300 3G3RV-PFI3800-SE A, 100 m 800 31.0
Type Model Description Function
Feedback speed control card
PG-A2 / 3G3FV-PPGA2
PG speed controller card
(used for V/f control with PG or
flux vector)
Phase A pulse (single pulse) inputs (voltage, complementary, open collector input)
PG frequency range: Approx. 30 kHz max.
[Power supply output for PG: +12 V, max. current 200 mA]
Pulse monitor output: +12 V, 20 mA
PG-B2 / 3G3FV-PPGB2 Phase A and B pulse inputs (exclusively for complementary input)
PG frequency range: Approx. 30 kHz max.
[Power supply output for PG: +12 V, max. current 200 mA]
Pulse monitor output: Open collector, +24 V, Max. current 30 mA
PG-D2 / 3G3FV-PPGD2 Phase A pulse (differential pulse) input for V/f control (RS-422 input)
PG frequency range: Approx. 300 kHz max.
[Power supply output for PG: +5 V or +12 V, max. current 200 mA]
Pulse monitor output: RS-422
PG-X2 / 3G3FV-PPGX2 Phase A, B and Z pulse (differential pulse) inputs (RS-422 input)
PG frequency range: Approx. 300 kHz max.
[Power supply output for PG: +5 V or +12 V, max. current 200 mA]
Pulse monitor output: RS-422
PG-Z2 Phase A, B and Z pulse (differential pulse) inputs (RS-422 input)
PG frequency range: Approx. 300 kHz max.
[Power supply output for PG: +5 V or +12 V, max. current 200 mA]
Pulse monitor output: RS-422
Dual channel encoder: 1st channel A, B, Z / 2nd channel A, B, Z or open collector.
Y203-EN2-02-Katalog.book Seite 284 Mittwoch, 24. Mai 2006 2:22 14
Varispeed F7 285
C Communication option cards
D Reference option cards
E PLC option cards
Type Model Description Function
Communication option card
3G3RV-PDRT2 DeviceNet option card Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through DeviceNet communication with the
host controller.
SI-P1 PROFIBUS-DP option card Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through PROFIBUS-DP communication
with the host controller.
SI-S1 CANopen option card Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through CANopen communication with the
host controller.
SI-J LONWORKS option card Used for HVAC control, running or stopping the inverter, setting or referencing parameters,
and monitoring output current, watt-hours, or similar items through LONWORKS communi-
cations with peripheral devices.
CM090 Ethernet option card MODBUS TCP/IP ethernet interface unit.
SI-T MECHATROLINK - II
option board
High speed motion bus.
Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through MECHATROLINK-II communica-
tion with the host controller.
Host controller: TrajeXia, MCH or MP series1
1. Please refer to TrajeXia, MCH or MP series section for host controllers detailed information.t
Type Model Description Function
Reference option card
AI-14U / 3G3IV-PAI14U
Analog input card
2 channel high resolution analog input card
Channel 1: 0 to 10 V (20 KΩ)
Channel 2: 4 to 20 mA (250 Ω)
Resolution 14 bit
AI-14B / 3G3IV-PAI14B
3 Channel high resolution analog input card
Signal level: -10 to +10V (20 KΩ)
s4 to 20 mA (250 Ω)
•Resolution: 13 bit + sign
DI-08 / 3G3IV-PDI08 Digital reference card 8 bit digital speed reference input card
DI-16H2 / 3G3IV-PDI16H2 16 bit digital speed reference input card
Type Model Description Function
PLC option
3G3RV-P10ST8-E
3G3RV-P10ST8-DRT-E
PLC option
Full PLC features, wireless installation and seamless access to the inverter parameters and
analogue/digital inputs and outputs.
Embedded Compubus/S fieldbus
Standard OMRON tools can be used for programming
PLC option with DeviceNet
Same features as standard model with DeviceNet support.
Y203-EN2-02-Katalog.book Seite 285 Mittwoch, 24. Mai 2006 2:22 14
286 Frequency inverters
F Accessories
F Computer software
Type Model Description Function
Digital operator
JVOP-160-OY
5 lines LCD digital operator
7 language support
Panel cutout installation
JVOP-161-OY
7 segment LED digital operator
Accessories
3G3IV-PCN126
3G3IV-PCN326 Digital operator extension cable
1 meter
3 meters Extension cable to connect inverter and digital operator.
3G3IV-PCN329-E PC configuration cable Cable to connect the inverter to PC.
Type Model Description Function
Software
CX-drive Computer software Configuration and monitoring software tool for drives.
CX-One Computer software Complete OMRON automation software including CX-drive
70 70
14.5
2.5
20
44
15.8 6.4
(60)
57
Through
Hole
120
111
120
2-M3 MTG Holes
Panel
Panel cutout
Y203-EN2-02-Katalog.book Seite 286 Mittwoch, 24. Mai 2006 2:22 14
Varispeed F7 287
G Braking unit, braking resistor unit
Inverter
Braking unit
Braking resistor unit1
1. When connecting a mounting type resistor or braking resistor unit, set system constant L3-04 to 0 (stall prevention disabled during deceleration). If op-
erating without changing the constant, motor does not stop at set deceleration time.
Inverter-mounted type
(3 %ED, 10 sec max)2
2. When connecting mounting type braking resistor, set system constant L8-01 to 1 (braking resistor protection enabled).
Separately-installed type (10 %ED, 10 sec. max.)3
3. Load factor during deceleration to stop a load with constant torque. With constant output or continuous regenerative braking, the load factor is smaller
than the specified value.
4. Resistance value per one braking unit. Select a resistance value that is larger than connectable minimum resistance value to obtain enough braking
torque.
5. For an application with large regenerative power such as hoisting, the braking torque or other items may exceed the capacity of a braking unit with a
braking resistor in a standard combination (an result in capacity overload). Contact your OMRON representatives when the braking torque or any other
item exceeds the values in the table.
Voltage Max. applicable
motor output
kW
Model
CIMR-
F7Z_
Model
CDBR_ No. of
used Model
ERF-150WJ_ Resis-
tance No. of
used Braking
torque % Model
LKEB_ Specifications
of resistor No. of
used Braking
torque %
Connectable
min resistance
value Ω
200 V
class
0.4 20P4
Built-in
201 200 Ω1 220 20P7 70 W 200 Ω1 220 48
0.75 20P7 201 200 Ω1 125 20P7 70 W 200 Ω1 125 48
1.5 21P5 101 100 Ω1 125 21P5 260 W 100 Ω1 125 48
2.2 22P2 700 70 Ω1 120 22P2 260 W 70 Ω1 120 16
3.7 23P7 620 62 Ω1 100 23P7 390 W 40 Ω1 125 16
5.5 25P5
--- ---
25P5 520 W 30 Ω1 115 16
7.5 27P5 27P5 780 W 20 Ω1 125 9.6
11 2011 2011 2400 W 13.6 Ω1 125 9.6
15 2015 2015 3000 W 10 Ω1 125 9.6
18.5 2018 2015 3000 W 10 Ω1 125 9.6
22 2022 2022B 1 2022 4800 W 6.8 Ω1 125 6.4
30 2030 2015B 2 2015 3000 W 10 Ω2 125 9.6
37 2037 2015B 2 2015 3000 W 10 Ω2 100 9.6
45 2045 2022B 2 2022 4800 W 6.8 Ω2 120 6.4
55 2055 2022B 2 2022 4800 W 6.8 Ω2 100 6.4
75 2075 2110B 1 2022 4800 W 6.8 Ω3 110 1.6
90 2090 2110B 1 2022 4800 W 6.8 Ω4 120 1.6
110 2110 2110B 1 2018 4800 W 8 Ω5 100 1.6
400 V
class
0.4 40P4
Built in
751 750 Ω1 230 40P7 70 W 750 Ω1 230 96
0.75 40P7 751 750 Ω1 130 40P7 70 W 750 Ω1 130 96
1.5 41P5 401 400 Ω1 125 41P5 260 W 400 Ω1 125 64
2.2 42P2 301 300 Ω1 115 42P2 260 W 250 Ω1 135 64
3.7 43P7 201 200 Ω1 110 43P7 390 W 150 Ω1 135 32
4.0 44P0
5.5 45P5
--- ---
45P5 520 W 100 Ω1 135 32
7.5 47P5 47P5 780 W 75 Ω1 130 32
11 4011 4011 1040 W 50 Ω1 135 20
15 4015 4015 1560 W 40 Ω1 125 20
18.5 4018 4018 4800 W 32 Ω1 125 19.2
22 4022 4030B 1 4022 4800 W 27.2 Ω1 125 19.2
30 4030 4030B 1 4030 6000 W 20 Ω1 125 19.2
37 4037 4045B 1 4037 9600 W 16 Ω1 125 12.8
45 4045 4045B 1 4045 9600 W 13.6 Ω1 125 12.8
55 4055 4030B 2 4030 6000 W 20 Ω2 135 19.2
75 4075 4045B 2 4045 9600 W 13.6 Ω2 145 12.8
90 4090 4220B 1 4030 6000 W 20 Ω3 100 3.2
110 4110 4220B 1 4030 6000 W 20 Ω3 100 3.2
132 4132 4220B 1 4045 9600 W 13.6 Ω4 140 3.2
160 4160 4220B 1 4045 9600 W 13.6 Ω4 140 3.2
185 4185 4220B 1 4045 9600 W 13.6 Ω4 120 3.2
220 4220 4220B 1 4037 9600 W 16 Ω5 110 3.2
300 4300 4220B 2 4045 9600 W 13.6 Ω6 110 3.2
Y203-EN2-02-Katalog.book Seite 287 Mittwoch, 24. Mai 2006 2:22 14
288 Frequency inverters
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I23E-EN-02
Y203-EN2-02-Katalog.book Seite 288 Mittwoch, 24. Mai 2006 2:22 14
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
CIMR-F7Z42P21 B CIMR-F7Z47P5 B CIMR-F7Z47P5B CIMR-F7Z42P21B