Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8777 Multi-Conductor - Shielded Twisted Pair Cable For more Information please call 1-800-Belden1 General Description: 22 AWG stranded (7x30) tinned copper conductors, polypropylene insulation, twisted pairs individually Beldfoil(R) Shielded (100% coverage), 22 AWG stranded tinned copper drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material Dia. (mm) 3 22 7x30 TC - Tinned Copper 0.762 Total Number of Conductors: 6 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PP - Polypropylene 0.279 Inner Shield Inner Shield Material: Layer # Inner Shield Trade Name Type Inner Shield Material Coverage (%) 1 Beldfoil(R) Tape Aluminum-Polyester 100.000 Inner Shield Drain Wire AWG: AWG 22 Inner Shield Drain Wire Stranding: 7x30 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.864 Overall Cable Overall Nominal Diameter: 6.934 mm Pair Pair Color Code Chart: Number Color 1 Black & Red 2 Black & White 3 Black & Green Pair Lay Length & Direction: Lay Length (mm) Twists (twist/m) Direction 44.450 22.639 Left Hand Page 1 of 3 01-16-2014 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8777 Multi-Conductor - Shielded Twisted Pair Cable Mechanical Characteristics (Overall) Storage Temperature Range: -40C To +80C Operating Temperature Range: -20C To +80C UL Temperature Rating: 80C (UL AWM Style 2919) Bulk Cable Weight: 58.040 Kg/Km Max. Recommended Pulling Tension: 351.408 N Min. Bend Radius/Minor Axis: 69.850 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM NEC Articles: 800 CEC/C(UL) Specification: CM AWM Specification: UL Style 2919 (30 V 80C) EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading CSA Flame Test: FT1 Suitability Suitability - Indoor: Yes Plenum/Non-Plenum Plenum (Y/N): No Plenum Number: 88777, 87777, 82777 Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 50 Nom. Inductance: Inductance (H/m) 0.59058 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 98.43 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 180.455 Nominal Velocity of Propagation: Page 2 of 3 01-16-2014 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8777 Multi-Conductor - Shielded Twisted Pair Cable VP (%) 66 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 49.215 Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 34.779 Ohm/km Max. Operating Voltage - UL: Voltage Description 300 V RMS Listed type CM 30 V RMS AWM 2919 Max. Recommended Current: Description Current 10C temperature rise 2 Amps per conductor @ 25C ambient Put Ups and Colors: Item # Putup Ship Weight Color 8777 060U1000 305 MT 18.597 KG CHROME Notes Item Desc 3 SH PR #22 PP PVC 8777 060U500 152 MT 9.525 KG CHROME 3 SHLD PR #22 PP PVC 8777 060100 30 MT 2.132 KG CHROME 8777 0601000 305 MT 19.505 KG CHROME C 3 SHLD PR #22 PP PVC 8777 06010000 3,048 MT 208.653 KG CHROME CY 3 SHLD PR #22 PP PVC 8777 0601640 500 MT 31.244 KG CHROME C 3 SHLD PR #22 PP PVC 8777 060250 76 MT 5.103 KG CHROME C 3 SHLD PR #22 PP PVC 8777 0603280 1,000 MT 62.487 KG CHROME C 3 SHLD PR #22 PP PVC 8777 060500 152 MT 9.752 KG CHROME C 3 SHLD PR #22 PP PVC 8777 0605000 1,524 MT 97.523 KG CHROME C 3 SHLD PR #22 PP PVC 3 SHLD PR #22 PP PVC Notes: C = CRATE REEL PUT-UP. Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'. Revision Number: 2 Revision Date: 08-02-2013 (c) 2014 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 01-16-2014