E5_C General purpose temperature controllers
High performance & simplicity
The next generation E5_C temperature controller is setting a new global standard in
terms of precision and user-friendly design. Best control performance, easy set-up
and outstanding visibility of the white IP66 LCD display have been integrated into a
space-saving housing with only 60 mm* of depth.
•Fast and precise regulation: 50ms sampling loop period time
•Easy to set up, and operate intuitively via CX-Thermo without power supply
•Best contrast display using white LCD technology which is visible from a far
distance and from any angle
•Useful alarm and diagnosis functions for secure operation
Specifications
E5GC E5CC E5EC E5AC
Power supply voltage
Operating voltage range
Power consumption
Sensor input
Input impedance
Control method
Indication accuracy
(at the ambient temperature of 23°C)
Auto-Tuning
Self-Tuning
Control output
Relay output
Voltage output
(for driving SSR)
Linear current output
Auxiliary output
Number of outputs
Output specifications
Event input
Number of inputs
External contact input
specifications
Setting method
Indication method
Multi SP
Other functions
Ambient operating temperature
Ambient operating humidity
Storage temperature
Degree of protection
Input sampling period
Size in mm (HxWxD)
Note: *1. The indication accuracy of K thermocouples in the -200 to 1,300°C range, T and N thermocouples at a temperature of -100°C max., and U and L thermocouples at any temperatures is
±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max. is not specified. The indication accuracy of B thermocouples at a temperature of
400 to 800°C is ±3°C max. The indication accuracy of the R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of W thermocouples is
(±0.3% of PV or ±3°C, whichever is greater) ±1 digit max. The indication accuracy of PL II thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max.
*2. Only four set points are selectable for event inputs.
*3. Simple transfer output, and work bit message are only for E5GC.
–Temperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer : Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
–Analog input
Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1: 1 connection when connecting the ES2-HB/THB.)
ON/OFF control or 2-PID control (with auto-tuning)
Thermocouple:
(±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max.*1
Platinum resistance thermometer:
(±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Thermocouple:
(±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max.*1
Platinum resistance thermometer:
(±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Potentiometer input: ±5% FS ±1 digit max.
Yes, 40%/100% MV output limit selection. When using Heat/Cool: Independent Heat & cool PID can be set by Auto-tuning.
Yes
Output voltage: 12 VDC ±20% (PNP), max.
load current: 21 mA, with short-circuit protection circuit
Output voltage: 12 VDC ±20% (PNP), max.
load current: 40 mA, with short-circuit protection circuit
(The maximum load current is 21 mA for models with two control outputs.)
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
1 or 2 (depends on model) 2 or 4 (depends on model) 2, 4 or 6 (depends on model)
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Digital setting using front panel keys
11-segment digital display and individual indicators
Up to eight set points (SP0 to SP7) can be
saved and selected using the event inputs,
key operations, or serial communications.
*2
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT,
MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations,
temperature status display, simple programming, moving average of input value, display brightness setting, simple transfer output, and work bit message
*3
Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs,
key operations, or serial communications.
–10 to 55°C (with no condensation or icing), for 3-year warranty: -10 to 50°C with standard mounting (with no condensation or icing)
25% to 85%
–25 to 65°C (with no condensation or icing)
1 or 2 (depends on model) 3 4
50 ms
24×48×90
(Models with Screw Terminal Blocks)/
24×48×93(Models with Screwless
Clamp Terminal Blocks)
48×48×64 48×96×64 96×96×64
Front panel: IP66, Rear case: IP20, Terminals: IP00
SPST-NO, 250 VAC, 2 A (resistive load),
electrical life; 100,000 operations,
minimum applicable
load: 5 V, 10 mA (reference value)
SPST-NO, 250 VAC, 3 A (resistive load),
electrical life; 100,000 operations,
minimum applicable
load: 5 V, 10 mA (reference value)
SPST-NO, 250 VAC, 5 A (resistive load),
electrical life; 100,000 operations,
minimum applicable load: 5 V, 10 mA (reference value)
SPST-NO relay outputs, 250 VAC, :
2 A (resistive load),
Electrical life: 100,000 operations,
Minimum applicable load: 10 mA at
5 V (reference value)
SPST-NO. relay outputs, 250 VAC,
Models with 4 outputs: 2 A (resistive load),
Electrical life: 100,000 operations,
Minimum applicable load: 10 mA at 5 V (reference value)
SPST-NO relay outputs, 250 VAC,
Models with 1 or 2 outputs:
3 A (resistive load), or Models with
3 outputs: 2 A (resistive load),
Electrical life: 100,000 operations,
Minimum applicable load: 10 mA at
5 V (reference value)
A in model number: 100 to 240 VAC, 50/60 Hz D in model number: 24 VAC, 50/60 Hz; 24 VDC
85% to 110% of rated supply voltage
5.9VA max. at 100 to 240 VAC, and
3.2VA max. at 24 VAC or
1.8W max. at 24 VDC
Models with option selection of 000:
5.2 VA max. at 100 to 240 VAC, and
3.1 VA max. at 24 VAC or1.6 W max.
at 24 VDC All other models: 6.5 VA max.
at 100 to 240 VAC, and 4.1 VA max.
at 24 VAC or 2.3 W max. at 24 VDC
Models with option selection of 000:
6.6 VA max. at 100 to 240 VAC, and
4.1 VA max. at 24 VAC or 2.3 W max.
at 24 VDC All other models: 8.3 VA max.
at 100 to 240 VAC, and 5.5 VA max.
at 24 VAC or 3.2 W max. at 24 VDC
Models with option selection of 000:
7.0 VA max. at 100 to 240 VAC, and
4.2 VA max. at 24 VAC or 2.4 W max.
at 24 VDC All other models: 9.0 VA max.
at 100 to 240 VAC, and 5.6 VA max.
at 24 VAC or 3.4 W max. at 24 VDC
* Excluding E5GC
14