OM4003ST - OM4007ST
3.2
205 Crawford Street, Leominster, MA 01453 USA (508) 534-5776 FAX (508) 537-4246
MAXIMUM RATINGS
50
20
10
5
3
1
0.5
0 0.1 0.2 0.3 0.5 0.5 0.6 0.7 0.8 0.9 1
VF- INSTANTANEOUS VOLTAGE (VOLTS)
150°C
175°C
100°C
TJ= 25°C
Typical Forward Voltage
10
1
0.1
0.01
20 40 60 80 100 120
VR- REVERSE VOLTAGE (VOLTS)
TJ= 125°C
TJ= 150°C
TJ= 100°C
Typical Reverse Current
IR- REVERSE CURRENT (mA)
TJ= 25°C
Rating Symbol OM Unit
4003 4004 4005 4006 4007
Peak Repetitive Reverse Voltage VRRM 60 70 80 90 100 Volts
Working Peak Reverse Voltage VRWM
DC Blocking Voltage VR
Average Rectified Forward Current (Rated VR) TC = 100° C IF(AV) 10 Amps
Peak Repetitive Forward Current IFRM 20 Amps
(Rated VR, Square Wave, 20 kHz) TC= 100° C
Nonrepetitive Peak Surge Current IFSM 150 Amps
(Surge applied at rated load conditions halfwave,
single phase, 60 Hz)
Peak Repetitive Reverse Surge Current (2 µs, 1 kHz) IRRM 0.5 Amps
Operating Junction Temperature TJ-65 to +150 ° C
Storage Temperature Tstg -65 to +175 ° C
THERMAL CHARACTERISTICS
Maximum Thermal Resistance RqJC 3 ° C/W
ELECTRICAL CHARACTERISTICS
Maximum Instantaneous Forward Voltage (1) VFVolts
(iF= 10 Amp, TC= 125° C) .725
(iF= 10 Amp, TC= 25° C) .825
Maximum Instantaneous Forward Reverse Current (1) iRmA
(Related dc Voltage, TC= 125° C) 150
(Related dc Voltage, TC= 25° C) 5
(1) Pulse Test: Pulse Width = 300 µs, Duty Cycle 2%
IF- INSTANTANEOUS FORWARD
CURRENT (AMPS)