TGP110 10MHz Pulse Generator with Delay
Thurlby Thandar Instruments Ltd. operates a policy of continuous development and re-
serves the right to alter specifications without prior notice.
Designed and built in the EEC by:
Thurlby Thandar Instruments Ltd.
Glebe Road, Huntingdon. Cambs. PE18 7DX England
Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409
e-mail: sales@ttinst.co.uk Web: http://www.ttinst.co.uk
THURLBY THANDAR INSTRUMENTS TGP110 10MHz Pulse Generator
PERIOD PULSE WIDTH PULSE DELAY
TTL OUT MAIN OUTSYNC OUT
AMPLITUDE
FUNCTION /MODE
Manual
Trigger
Run
Triggered
Gated
TRIGGER IN
OPERATE
On
Off
10V Max.
Normal
Complement
1V - 10V
0.1V - 1V
50
100ns
1ms
100us
1s
100ms
10ms
10us
1us
500ms
50us 500us
50ns
500ns
5US 5ms
50ms
500ms
50us 500us
50ns
500ns
5us 5ms
50ms
COREL5
11110 1010
Square Double Pulse
Pulse Delayed
Pulse 56
4
321
7
8
9
10
Overlap Overlap
THURLBY THANDAR INSTRUMENTS
0.1Hz to 10MHz frequency range
50ns minimum pulse width; fully variable pulse delay
Squarewave, double pulse and delayed pulse modes
Free-run, gated and triggered modes
50 output, variable 0.1V to 10V; TTL and sync outputs
An essential instrument
Thegenerationofpulsesforthestimulusandcontrolofelectronicsystems
isbeyond thecapability ofall butthe mostsophisticated offunction gener-
ators.
The architecture of a dedicated pulse generator enables it to generate
pulses of a set width regardless of the repetition rate offering duty cycles
which can extend down to 1 in 100 million.
Inadditiontocontinuousoperation,singleormultiplepulsescanbegener-
ated in response to trigger or gating signals with precisely defined timing
relationships.
A dedicated pulse-waveform output amplifier provides flat top pulses with
fast rise and fall times at variable amplitude.
Variable delay
The TGP110 offers selectable delay between the sync output and pulse
output. In triggered mode this also sets the delay between a trigger signal
and the start of the pulse.
Wide pulse range
TheTGP110cangeneratepulsewidthsintherange50nsto5s. Thereare
eight overlapping decade ranges with vernier control within each range.
The period range is 100ns to 10s, equivalent to a repetition rate range of
10MHz to 0.1Hz. Delay is independently adjustable over the same range
as pulse width.
A complement switch inverts the mark-space polarity.
Squarewave and double pulse
Insquaremode,squarewavesaregeneratedatafrequencysetbythepe-
riod controls alone. This provides a convenient means of generating vari-
able period edges where the pulse width is unimportant, for example.
Indoublepulsemode,asecondpulseisgeneratedwithineveryperiodata
set delay after the start of the first pulse. The delay is independently ad-
justable.
SPECIFICATIONS
PERIOD, PULSE WIDTH, DELAY
Each parameter is variable within 8 overlapping decade ranges with a vernier
providing continuously variable control within each range.
PERIOD
Range: 100nsec to 10sec (10MHz to 0·1Hz).
Jitter: <0.1%.
PULSE WIDTH
Range: 50nsec to 5sec
Jitter: <0.1%.
DELAY
Range: 50nsec to 5sec
TRIGGER, GATE
RUN
Normal operational mode in which pulses are generated continuously at
0.1Hz to 10MHz.
TRIGGERED
DC to 10MHz pulse train in synchronism with external trigger pulses; pulse
width determined by pulse width controls. Trigger can be generated manually
from front panel button.
GATED
0·1Hz to 10MHz pulse train, parameters set by period and pulse width con-
trols, starts synchronously with leading edge of gate input. Last pulse is com-
pleted at the end of gating period. Gating signal can be generated manually
from front panel button.
PULSE MODES
NORMAL PULSE
One pulse is generated each period. The delay setting is ignored.
SQUAREWAVE
0·1Hz to 10MHz squarewave, frequency set by the period controls. Pulse
width and delay settings ignored.
Mark : Space ratio: 1:1 ±10%.
DOUBLE PULSE
A second pulse is generated after a delay set by the delay controls; the delay
is related to the leading edge of the first pulse.
DELAYED PULSE
A pulse is generated after a delay set by the delay controls; the delay is re-
lated to rising edge of the trigger signal.
INPUTS
GATE/TRIG INPUT
Frequency range: DC- 10MHz
Signal range: TTL threshold; max. input ±10V.
Min. pulse width: >30nsec.
Input Impedance: Typically 10k.
OUTPUTS
50OUTPUT
Amplitude: Two switch selectable ranges of 0·1V - 1·0V and
1V - 10V from 50. (50mV to 500mV and 500mV to 5V
into 50). Adjustable within ranges by a single turn ver-
nier.
Rise/Fall Times: Typically 10nsec into 50load. Maximum 15ns.
Aberrations: Typically <5% for output set at >20% of range maxi-
mum, into 50.
AUX OUTPUT
Duplicates 50output but at a fixed CMOS/TTL level.
SYNC OUTPUT
Amplitude: A positive going pulse at CMOS/TTL level.
Timing: Leading edge starts >20nsec before the TTL/50out-
put transition.
Duration: Typically 30nsec.
COMPLEMENT SWITCH
Inverts the AUX and 50outputs.
GENERAL
Power: 230V or 115V AC nominal 50/60Hz, adjustable internally;
operating range ±14% of nominal; 20VA max.
Size: 140 x 220 x 230mm (HxWxD)
Weight: 1.6kg (3.5lb)
Operating Range: + C to 40°C, 20-80% RH.
Storage Range: - 40°C to 70°C
Safety: Complies with EN61010-1.
EMC: Complies with EN55081-1 and EN50082-1.
Note: This is a faxable data sheet, a colour brochure is also available.